EMC FILTERS Single-Phase Filters, Three-Phase Filters, Three-Phase + Neutral Line Filters, DC Filters, Screened Room Filters (3Ph+N) , Output Ferrites, dV/dt Output Filters , Feedthrough Filters PREMO EMC Filters INTRODUCTION Electromagnetic Interference Most electronic equipment generates electromagnetic interference,which in some cases may be intentional (a radiofrequency generator) or unwanted (electronic motor speed controller). This interference is mainly propagated in two ways, one via an energy conducting network, and the other through the air. These are called CONDUCTED INTERFERENCE (150 KHz TO 30 MHz) and RADIATED INTERFERENCE (30 MHz to 300 MHz), respectively. Also, electronic equipment can fail when working within an electromagnetic environment. This tendency to fail is very common and is known as ELECTROMAGNETIC SUSCEPTIBILITY. The relationship between perturbing and victim equipment is known as ELECTROMAGNETIC COMPATIBILITY. These terms are abbreviated as follows: EMC = Electromagnetic Compatibility EMS = Electromagnetic Susceptibility CE = Conducted Interference (Emission) RE = Radiated Interference (Emission) EMI = Electromagnetic Interference Conducted Interference The interference conducted through an energy conduction network has two propagation routes. COMMON MODE. Also called ASYMMETRIC. This perturbation is present between the safety earth and the conduction lines. DIFFERENTIAL MODE. Also called SYMMETRIC. This perturbation is present in the conduction lines. Radiated Interference This propagation through space is caused by the fact that the equipment, or some part of it, is acting as an efficient antenna over a given frequency range. It is captured, by induction, in the power supply cable, or even directly by some internal element of the device which acts as an efficient receiving antenna over the same frequency range as the interfering signal. How to minimize the interference In order to avoid a high degree of contamination of the power supply lines with electromagnetic interference (EMI), equipment which could cause its generation should incorporate a power line filter, in order to block, as far as possible, the passing of this interference. Also, as it is not possible to have a clean power supply line, the line filter also prevents the passing of this interference to the equipment. a) The filter has to attenuate the interference passed to the power line. b) The filter has to attenuate the interference from the power line. Basically, the filters should be designed as low-pass filters, to achieve a significant attenuation in the frequency band which covers the interference, and a minimal attenuation at the power line frequency. Of course, the design of a filter has to take into account also that its characteristic impedance should be as unmatched as possible to that of the interference in order that the perturbation is reflected back to its source. 258 Filter characteristics The filters should cover the range of frequencies between 10 KHz and 300 MHz, although the range can be different depending on the standard to be applied. They should generate high insertion losses within the specified frequency range. The insertion losses should be defined for both SYMMETRIC and ASYMMETRIC modes. As the filters are normally installed in the power supply line, they should comply with the appropiate standards. PREMO EMC Filters INTRODUCTION Special Line Filters In this catalogue it is possible to select power line filters of one or more stages, with printed circuit connection, spade fasterners, cables, IEC connector incorporated, screw or clip mounting, and a wide variety of accessories such as fuses, voltage selectors, switches etc... If you do not find the type which best suits your requirements for current attenuation, size, mounting, etc. We can manufacture the model which suits your requirements on request. PREMO has a laboratory equipped with the most modern and sophisticated instrumentation to be found on the market, and its manufacturing plant uses a flexible production system which allows it to offer made to measure solutions. Selection and installation The choice of the most suitable power line filter and its installation in the equipment are of primary importance if we wish to fully benefit from its features. As can be seen later on, we have models with and incorporated connector and direct access from the exterior, and others for internal mounting on the chassis or the printed circuit. In all cases the external shielding of the power line filter should be connected to the equipment chassis and the power and load lines should be as short as possible and sufficiently separated. Verification Tests In the final stage of the manufacturing process, the PREMO power line filters have to pass strict verification tests to check their reliability and safety for use. The methods followed are described below: 1) High voltage test Apply voltage of: 1850 VAC 50 Hz 3s between L-N/PE 1750 VDC 3s between L/N Medical series (M) 2500 VAC between L-N/PE 2) Leakage current test The verification is carried out according to standards using specially designed equipment. The limits are indicated for each series. See diagram in fig. 4. 3) Attenuation test Attenuation is defined as the relation, in dB between the power input to the load with and without the filter over the full range of working frequencies. See diagrams for the measurement of attenuation in common and differential modes in fig. 5 and 6. 259 PREMO EMC Filters INTRODUCTION General Technical Characteristics - Rated voltage single phase: 250 VAC 50/60 Hz - Rated voltage three phase: 520/760 VAC 50/60 Hz - Rated current: The rated current, INOM is given for an ambient temperature the permissible operating current, IPERM, must be reduced according to the follwing formula: - Dielectric strength test: L-N / PE 1850 VAC 3s L/N 1750 VDC 3s - Leakage current: 250 V 50/60 Hz 0.552 x rated for 115 V 50/60 Hz - Climatic category: HPF/HMF - Component tolerance: L: -30%, +50% C: -20%, +20% R: -10%, +10% - Types of connexion: Z = Faston 6,30 x 0,8 mm X = Cables UL-1015 V = Pins for P.C.B Ø = 1.3/0,8 mm W = Screws M4 / M6 / M10 B = Terminal block P= Bus Bar Diagram Powerline Figure 4 Figure 5 260 Figure 6 FA (1-30A) FA-V (1-6A) FB (1-20A) FC (3-10A) FC1 FC2 FC3 FC4 FD (1-6A) CONSUMER ELECTRONICS LIFTS INDUSTRIAL AUTOMATION RENEWABLE ENERGY TELECOMUNICATIONS ELECTROMEDICAL DRIVES AND CONTROLS PREMO EMC Filters C-Series DTRF (20-50A) MILITAR APPLICATIONS TRANSPORT EMC Filter Chart by Application FDC (1-6A) FDV (1-10A) FE (1-30A) FEDC (25-1500A) FEH (1-30A) FEHV (6-30A) FF (3-20A) FFH (1-16A) FFHV (6-30A) FG/FGR - T (3-6A) FG/FGR - V (3-6A) FG/FGR (3-6A) FI (2-10A) FI-F (2-10A) FI-FM (2-10A) FL (1-10A) FOVT (8-70A) FR/FRR (1-10A) FT (1-6A) FTA (3-6A) FTC (1-6A) FTC-C (1-6A) FTC-M (1-6A) FTCV (1-6A) FTCV-C (1-6A) FTCV-M (1-6A) FT-M (1-6A) FTN (1-6A) FTN-M (1-6A) FTO (1-6A) FTO-M (1-6A) FVBD (7-250A) FVDT (7-900A) FVDT-D (5-28A) FVNSB (8-200) FVRB (35-300A) FVSB (7-180A) FVST (6-660A) FVTC (10-1000A) FVTO-IV (6-180A) HCWMF (150-2500A) N-1 N-2 N-3 P-0999 (16-60A) P-Series PE (0,5-6A) PF (50-150A) PFT (3-150A) STF (8-200A) 261 PREMO EMC Filters RAPID GUIDE Single phase Filters CHASSIS PANEL MOUNTING PCB MOUNTING SCREENED General Medical Use For SMPS High Atten. Very High Atten. Metal Box Plastic Box ROOM FILTERS Use FA FG FC FE FB FA-V (1-6 A) PE (14 KHz-10 GHz) (1-30 A) (3-6 A) (3-10 A) (1-30 A) (1-20 A) FG-V (1-6 A) (0,5-6 A) FC1 (10-85 A) PF FGR FL FEH FF (150 KHz-10 GHz) (50-150 A) (3-6 A) (1-10 A) (1-30 A) (3-20 A) FC2 (10-85 A) FR/FRR FFH (1-30 A) (1-16 A) SMPS = Switched Mode Power Supply PCB = Printed Circuit Board FEHV FFHV (6-30 A) (6-30 A) Single phase Filters Chassis Panel Mounting with IEC Connector General Use Size reduced With Fuses Fuse + Switch FD (1-6 A) FTA (3-6 A) FI/FI-F (1-10 A) FT-FTN (1-6 A) FTC (1-6 A) General Use High Atten. FDC (1-6 A) FGT (3-6 A) Earth Choke Medical Use FI-FM (1-10 A) FT-M/FTN-M/FTC-M (1-10 A) Fuse + Switch + Voltage Selector FTCV (1-6 A) FTCV (1-6 A) FTCV-M (1-6 A) 3-Phase Filters 3-Phase + Neutral 3-Phase without neutral for frecuency inverters One Stage FVSB PFT FVST (3-150 A) (3-110 A) (7-180 A) STF FVTC (8-200 A) (10-1000 A) Double Stage FVTO-IV (7-280 A) FVNSB (8-200 A) Compact Size FVDB (7-250 A) FVDT (7-75 A) FVST FVDT (180-660 A) (100-900 A) DTRF (20-50 A) FVRB (35-300 A) FVDT-D (6-28 A) P-0999 4 kw - 16 A 11 kw - 36 A 18,5 kw - 55 A HCWMGF (150-2500 A) Dc Filters Name FEDC series Voltage Current 1200 Vdc (25-1500 A) Feedthorught Filters Voltage Current Topology P Series 250Vac/400 Vdc (10 - 63 A) Single Line Pi Circuit C Series 250Vac/400 Vdc (10 - 250 A) Single Line C Circuit Name 262 Frecuency Inverters Output Screened Room Filters 3-Phases + Neutral N-1 N-2 N-3 (16-125 A) FC3 (14 Khz - 10 Ghz) (16-125 A) FOVT (8-70 A) (dV/dT) FC3 (150 Khz - 10 Ghz) (16-125 A) FA Single - Phase Filters Chassis Panel Mounting Single Phase Filter (1-30 A) General Purpose Chassis mounting single stage filter for general purpose. Good attenuation over a wide frequency range. Small size. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List TYPE FA-1V FA-1X I 1 Amp L1 2 mH CX 10 nF CY 2,2 nF FA-1Z FA-3V FA-3X FA-3Z FA-6V FA-6X FA-6Z FA-10X FA-10Z FA-20W FA-20Z FA-30W CONNECTION WEIGHT ±g 1,3mm PIN AWG18 wire 43 59 FASTON 6,3mm 1,3mm PIN 47 46 AWG18 wire FASTON 6,3mm 61 47 0,21 mA 1,3mm PIN AWG18 wire 48 55 0,45 mA FASTON 6,3mm AWG18 wire 49 130 0,45 mA FASTON 6,3mm M6 SCREW 124 565 0,21 mA FASTON 6,3mm M6 SCREW 150 646 HOUSING LCURRENT 205 204 0,21 mA 203 205 3 Amp 6 Amp 10 Amp 20 Amp 30 Amp 1,3 mH 0,8 mH 0,5 mH 0,48 mH 0,48 mH 10 nF 10 nF 100 nF 100 nF 33 nF 2,2 nF 204 203 2,2 nF 205 204 4,7 nF 203 213 4,7 nF 212 223 2,2 nF 216 223 0,21 mA 263 FB Single - Phase Filters High Attenuation Single Phase Filter (1-20 A) General Purpose Double stage filter. High attenuation. General purpose applications with high EMI levels. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d) Flammability class: UL 94 V2. Electrical schematics Product List 264 CONNECTION WEIGHT ±g 0,45 mA AWG18 WIRE FASTON 6,3mm 132 126 213 212 0,45 mA AWG18 WIRE FASTON 6,3mm 115 109 4,7 nF 213 212 0,45 mA AWG18 WIRE FASTON 6,3mm 133 125 100 nF 4,7 nF 217 216 0,45 mA AWG18 WIRE FASTON 6,3mm 246 240 100 nF 4,7 nF 223 221 0,45 mA M6 SGREW FASTON 6,3mm 682 500 TYPE I L1 CX CY HOUSING LCURRENT FB-1X FB-1Z 1 Amp 3 mH 100 nF 4,7 nF 213 212 FB-2X FB-2Z 2 Amp 2 mH 100 nF 4,7 nF FB-5X FB-5Z 5 Amp 1,5 mH 100 nF FB-10X FB-10Z 10 Amp 1 mH FB-20W FB-20Z 20 Amp 0,8 mH FC Single - Phase Filters SMPS Chassis Panel Mounting Single Phase Filter (3-10 A) For equipment using s.m.p.s. Chassis mounting double stage filter. High symmetrical attenuation. Switching mode power supplies. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List HOUSING LCURRENT CONNECTION WEIGHT ±g TYPE I L1 L2 CX CY FC-3X FC-3Z 3 Amp 3 mH 0,3 mH 100 nF 4,7 nF 215 214 0,45 mA AWG18 WIRE FASTON 6,3mm 170 164 FC-6X FC-6Z 6 Amp 1 mH 0,15 mH 100 nF 4,7 nF 217 216 0,45 mA AWG18 WIRE FASTON 6,3mm 205 199 FC-10X FC-10Z 10 Amp 0,5 mH 0,05 mH 100 nF 4,7 nF 217 216 0,45 mA AWG18 WIRE FASTON 6,3mm 249 242 Insertion Loss 265 FE Single - Phase Filters High Attenuation Single Phase Filter (1-20 A) General Purpose Chassis mounting single stage filter. General purpose. Good attenuation in a wide frecuency range. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List TYPE FE-1X FE-1Z FE-3X FE-3Z FE-6X FE-6Z FE-10X FE-10Z FE-20W FE-20Z FE-30W 266 I L1 CX CY 1 Amp 3 mH 100 nF 4,7 nF 3 Amp 2 mH 100 nF 4,7 nF 6 Amp 0,75 mH 100 nF 4,7 nF 10 Amp 1 mH 100 nF 4,7 nF 20 Amp 0,48 mH 100 nF 4,7 nF 30 Amp 0,48 mH 100 nF 4,7 nF HOUSING LCURRENT CONNECTION 211 210 211 210 211 210 211 210 223 216 223 0,45 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm M6 SCREW FASTON 6,3mm M6 SCREW WEIGHT ±g 133 119 114 108 115 109 136 130 561 429 647 FEH Single - Phase Filters High Attenuation Single Phase Filter (1.30A) General Purpose Chassis mounting single stage filter. High attenuation for noisy circuits. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List TYPE FEH-1X FEH-1Z FEH-3X FEH-3Z FEH-6X FEH-6Z FEH-10X FEH-10Z FEH-16X FEH-16Z FEH-20Z FEH-30W I L1 CX CY 1 Amp 12 mH 150 nF 4,7 nF 3 Amp 2,5 mH 150 nF 4,7 nF 6 Amp 1 mH 150 nF 4,7 nF 10 Amp 0,80 mH 150 nF 4,7 nF 16 Amp 0,65 mH 150 nF 4,7 nF 20 Amp 30 Amp 0,60 mH 0,67 mH 150 nF 470 nF 4,7 nF 10 nF HOUSING LCURRENT CONNECTION 209 208 209 208 209 208 209 208 211 210 214 220 0,45 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm AWG18 wire FASTON 6,3mm FASTON 6,3mm M6 SCREW WEIGHT ±g 106 100 106 100 106 100 106 100 119 113 164 210 Insertion Loss 267 Single - Phase Filters FEHV High Attenuation Chassis Panel Mounting Single Phase Filter for Frequency Inverters (6-30A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. For single phase frecuency inverters Hipot test voltage: L/N-›PE: 1800Vac 2s. Double stage filter. L-›N: 1700 Vdc 2s. Special performance for single phase frecuency Application class:HPF Acc. TO DIN inverters. 40040 (-25ºC/+85ºC/95% RH, 30d). Very high asymmetrical attenuation. Flammability class: UL 94 V2. Product List TYPE FEHV-6B FEHV-6X FEHV-6Z FEHV-10B FEHV-10Z FEHV-16B FEHV-16Z FEHV-20B FEHV-30B I L2 R (Ω) CX CY 6 mH 6 Amp 10 mH 25,6 µH 680 K 940 nF 47 nF 6 mH 10 Amp 6 mH 25,6 µH 680 K 940 nF 47 nF 16 Amp 4 mH 25,6 µH 470 K 2 µF 100 n F 20 Amp 3,5 mH 25,6 µH 470 K 30 Amp 2 mH 25,6 µH 220 K 2 µF 2 µF Insertion Loss 268 L1 100 nF 100 nF HOUSING LCURRENT CONNECTION 224 215 221 224 221 224 221 272 272 4,54 mA 4,54 mA 9,67 mA 9,67 mA 9,67 mA 4mm2 AWG18 WIRE FASTON 6,3mm 4mm2 FASTON 6,3mm 4mm2 FASTON 6,3mm 4mm2 6mm2 WEIGHT ±g 530 425 420 600 500 650 545 710 720 FF Single - Phase Filters Very High Attenuation Chassis Panel Mounting Single Phase Filter (3-20A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. General Purpose Double stage filter. High insertion loss. General purpose filter. Product List TYPE FF-3X FF-3Z FF-6X FF-6Z FF-10Z FF-20W FF-20Z I L1 L2 CX CY 3 Amp 2 mH 2 mH 100 nF 2,2 nF 6 Amp 0,75 mH 0,75 mH 100 nF 2,2 nF 10 Amp 0,50 mH 0,50 mH 100 nF 20 Amp 0,48 mH 0,48 mH 100 nF 2,2 nF 2,2 nF HOUSING LCURRENT CONNECTION 215 214 215 214 216 223 221 0,21 mA 0,21 mA 0,21 mA 0,21 mA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm FASTON 6,3mm M6 SCREW FASTON 6,3mm WEIGHT ±g 170 165 172 166 223 564 429 Insertion Loss 269 Single - Phase Filters FFH Very High Attenuation Chassis Panel Mounting Single Phase Filter (1-16A) Electrical schematics General Specifications General Purpose Double stage filter. Very high attenuation (Symmetrical and asymmetrical). For application with high EMI levels. Product List TYPE FFH-1X FFH-1Z FFH-3X FFH-3Z FFH-6X FFH-6Z FFH-10X FFH-10Z FFH-12X FFH-12Z FFH-16X FFH-16Z I L1 CX CY 1 Amp 22 mH 330 nF 4,7 nF 1M 3 Amp 10 mH 470 nF 4,7 nF 470K 6 Amp 7,8 mH 1 µF 4,7 nF 220K 10 Amp 4,5 mH 1 µF 4,7 nF 220K 12 Amp 3,25 mH 1 µF 4,7 nF 220K 16 Amp 1 µF 4,7 nF 220K Insertion Loss 270 Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. 2 mH R (Ω) HOUSING LCURRENT CONNECTION 215 214 217 216 219 218 219 218 219 218 223 221 0,45mA 0,45mA 0,45mA 0,45mA 0,45mA 0,45mA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm WEIGHT ±g 170 164 205 199 260 250 260 250 260 250 510 500 FFHV Single - Phase Filters Very High Attenuation Chassis Panel Mounting Single Phase Filter for Frequency Inverters (6-30A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. For single phase frequency inverters Double stage filter. Special high performance for single phase frequency inverters. Very high attenuation. Product List TYPE FFHV-6Z FFHV-10Z FFHV-12Z FFHV-16Z FFHV-25B FFHV-30B I L1 6 Amp 7,8 mH 10 Amp 4,5 mH 12 Amp 3,25 mH 16 Amp 2,8 mH 25 Amp 1,6 mH 30 Amp 1,6+0,8 mH CX CY 1 µF 1 µF 1 µF 1 µF 2,2 µF 2,2 µF 4,7 nF 4,7 nF 4,7 nF 4,7 nF 33 nF 33 nF HOUSING LCURRENT 218 271 271 225 272 273 0,45mA 0,45mA 0,45mA 0,45mA 3,19mA 3,19mA CONNECTION FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm 4mm2 6mm2 WEIGHT ±g 380 430 635 985 1120 1300 Insertion Loss 271 FG/FGR Single - Phase Filters Chassis Panel Mounting Medical Use Single Phase Filter (3-6A) Electrical schematics General Specifications General Purpose Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 2500Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d) Flammability class: UL 94 V2. Filter for electromedical equipment. Small size. FGR: With bleeder resistor. ZT: IEC connector version. V: PCB mounting version. Product List TYPE FG-3Z FG-3V FG-3X FG-3ZT FG-6Z FG-6V FG-6X FG-6ZT FGR-3Z FGR-3ZT FGR-3V FGR-3X FGR-6Z FGR-6ZT FGR-6V FGR-6X 272 I L1 CX 3 Amp 0,8 mH 10 nF 6 Amp 0,45 mH 10 nF 3 Amp 0,8 mH 10 nF 6 Amp 0,45 mH 10 nF HOUSING 203 205 204 241 203 205 204 241 203 241 205 204 203 241 205 204 LCURRENT 5µA 5µA 5µA 5µA CONNECTION WEIGHT ±g FASTON 6,3mm 1,3 mm PIN AWG18 WIRE FASTON 6,3mm FASTON 6,3mm 1,3 mm PIN AWG18 WIRE FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm 1,3 mm PIN AWG18 WIRE FASTON 6,3mm FASTON 6,3mm 1,3 mm PIN AWG18 WIRE 48 45 54 54 49 38 55 54 48 54 45 54 49 54 38 55 FL Single - Phase Filters Single Phase Chassis Panel SMPS Filter (1-10A) For equipment using s.m.p.s High attenuation for switching power supplies. Double stage filter. Very high asymmetrical attenuation. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List TYPE FL-1X FL-1Z FL-3X FL-3Z FL-3ZH FL-4X FL-4Z FL-6Z FL-10Z I L1 L2 CX CY 1 Amp 22 mH 1,2 mH 0,22 µF 4,7 nF 3 Amp 16 mH 0,03 mH 0,22 µF 4,7 nF 3 Amp 16 mH 0,25 mH 0,22 µF 4,7 nF 4 Amp 8 mH 0,06 mH 1 µF 22 nF 6 Amp 4 mH 10 Amp 4 mH 0,1 mH 0,47 µF 0,1 mH 0,47 µF 22 nF 22 nF HOUSING LCURRENT CONNECTION 213 212 213 212 216 217 216 221 221 0,45 mA 0,45 mA 0,45 mA 2,12 mA 2,12 mA 2,12 mA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm FASTON 6,3mm AWG18 WIRE FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm WEIGHT ±g 129 125 129 125 131 137 131 500 500 Insertion Loss 273 FR-FRR Single - Phase Filters Single Phase Chassis Panel Mounting Filter (1-30A) For equipment using s.m.p.s Chassis mounting filter for general purpose applications. Single stage filter. Low leakage current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List TYPE FR-1X FR-1Z FR-3X FR-3Z FR-6X FR-6Z FR-10X FR-10Z FR-20W FR-20Z FR-30W FRR-1X FRR-1Z FRR-3X FRR-3Z FRR-6X FRR-6Z FRR-10X FRR-10Z I L1 CX CY 1 Amp 3 mH 33 nF 2,2 nF 3 Amp 2 mH 33 nF 2,2 nF 6 Amp 0,8 mH 33 nF 2,2 nF 10 Amp 0,45 mH 33 nF 2,2 nF 20 Amp 0,45 mH 33 nF 2,2 nF 30 Amp 1 Amp 0,60 mH 3 mH 33 nF 33 nF 2,2 nF 0,47 nF 3 Amp 2 mH 33 nF 0,47 nF 6 Amp 0,8 mH 33 nF 0,47 nF 10 Amp 0,75 mH 33 nF 0,47 nF Insertion Loss 274 HOUSING LCURRENT CONNECTION 207 206 207 206 207 206 209 208 217 216 223 207 206 207 206 207 206 209 208 0,21 mA 0,21 mA 0,21 mA 0,21 mA 0,21 mA 0,21 mA 0,45 mA 0,45 mA 0,45 mA 0,45 mA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm M6 SCREW FASTON 6,3mm M6 SCREW AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm WEIGHT ±g 53 47 56 48 60 49 90 83 510 190 515 53 47 56 48 60 49 83 90 PE Plastic Case Filter for PCB Mounting Filter (0.5-6A) Single - Phase Filters Electrical schematics General Purpose General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Plastic case filter for PCB mounting. Low cost and space saving filter. Good attenuation for wide frequency range. Low leakage current < 0,25 mA. For digital logic circuits. Product List TYPE HOUSING LCURRENT CONNECTION WEIGHT ±g I L1 CX CY PE-05V PE-05V-E2 0,5 Amp 20 mH 10 nF 2,2 nF 201 202 0,21 mA PIN 0,8mm PIN 0,8mm 27 PE-1V PE-1V-E2 1 Amp 10 mH 10 nF 2,2 nF 201 202 0,21 mA PIN 0,8mm PIN 0,8mm 28 PE-3V PE-3V-E2 3 Amp 1,3 mH 10 nF 2,2 nF 201 202 0,21 mA PIN 0,8mm PIN 0,8mm 28 PE-6V PE-6V-E2 6 Amp 0,8 mH 10 nF 2,2 nF 201 202 0,21 mA PIN 0,8mm PIN 0,8mm 27 83 Insertion Loss 275 PF Single - Phase Filters General Purpose Single Phase Filter (50-150A) General Purpose Chasis mounting single stage filter for general purpose. High current. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class:UL 94 V2. Electrical schematics Product List TYPE I CX CY HOUSING LCURRENT CONNECTION WEIGHT ±g PF-50W PF-100W 50 Amp 0,45 mH 100 Amp 0,31 mH 2,2 µF 2,2 µF 10 nF 10 nF 274 274 0,97mA 0,97mA M6 SCREW M6 SCREW 3350 3950 PF-150W 150 Amp 0,28 mH 2,2 µF 10 nF 275 0,97mA M10 SCREW 3950 Insertion Loss 276 L1 FD/FDC/FDV Single - Phase Filters IEC Connector Filter (1-6A) Electrical schematics General Specifications IEC connector filter IEC connector filter. General purpose. FD: IEC connector filter. FDC: With earth inductor. High immunity. FDV: With voltage protection. Product List TYPE FD-1X FD-1Z FD-3X FD-3Z FD-6X FD-6Z FDC-1X FDC-1Z FDC-3X FDC-3Z FDC-6X FDC-6Z FDV-1X FDV-1Z FDV-3X FDV-3Z FDV-6X FDV-6Z I L1 CX CY 1 Amp 2 mH 10 nF 2,2 nF 3 Amp 1,3 mH 10 nF 2,2 nF 6 Amp 0,8 mH 10 nF 2,2 nF 1 Amp 2 mH 10 nF 2,2 nF 3 Amp 1,3 mH 10 nF 2,2 nF 6 Amp 0,8 mH 10 nF 2,2 nF 1 Amp 2 mH 10 nF 2,2 nF 3 Amp 1,3 mH 10 nF 2,2 nF 6 Amp 0,8 mH 10 nF 2,2 nF Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. HOUSING LCURRENT CONNECTION 242 241 242 241 242 241 244 243 244 243 244 243 244 243 244 243 244 243 0,21mA 0,21mA 0,21mA 0,21mA 0,21mA 0,21mA 0,21mA 0,21mA 0,21mA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm WEIGHT ±g 62 50 52 51 62 55 110 100 102 92 120 110 110 100 102 92 120 110 Insertion Loss 277 FI Single - Phase Filters Chassis Panel with IEC Connector Fused Filter (1-6A) Electrical schematics IEC Connector Filter With IEC connector and fuse. Small size. F: With two fuses. FM: With two fuses for electromedical applications. General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. (2500Vac for M version) L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Product List TYPE FI-2X FI-2Z FI-4X FI-4Z FI-6X FI-6Z FI-2XFM FI-2ZFM FI-4XFM FI-4ZFM FI-6XFM FI-6ZFM I L1 CX CY 2 Amp 2 mH 100 nF 2,2 nF 4 Amp 1,3 mH 100 nF 2,2 nF 6 Amp 0,8 mH 100 nF 2,2 nF 2 Amp 2 mH 100 nF - 4 Amp 1,3 mH 100 nF - 6 Amp 0,8 mH 100 nF - Insertion Loss 278 HOUSING LCURRENT CONNECTION 248 247 248 247 248 247 246 245 246 245 246 245 0,21mA 0,21mA 0,21mA 5µA 5µA 5µA AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm AWG18 WIRE FASTON 6,3mm WEIGHT ±g 86 80 86 80 86 80 92 86 92 86 92 86 FT/FTO Single - Phase Filters IEC Connector Filter (1-6A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. (2500Vac for M version) L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. IEC Connector Filter With IEC connector filter, fuse and switch. External connections by user. Small size. M: For electromedical applications. Product List TYPE FT-1Z FT-3Z FT-6Z FT-1ZM FT-3ZM FT-6ZM FTO-1Z FTO-3Z FTO-6Z FTO-1ZM FTO-3ZM FTO-6ZM I L1 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 2 mH 1,3 mH 0,8 mH 2 mH 1,3 mH 0,8 mH 2 mH 1,3 mH 0,8 mH 2 mH 1,3 mH 0,8 mH CX CY 10 nF 2,2 nF 10 nF - 10 nF 2,2 nF 10 nF - HOUSING LCURRENT CONNECTION 252 252 252 252 252 252 253 253 253 253 253 253 0,21mA 5µA 0,21mA 5µA FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm WEIGHT ±g 67 66 66 62 61 61 85 85 85 80 80 80 279 FTA Single - Phase Filters Small Size IEC Filter (3-6A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. IEC filter small size With IEC connector filter, fuse and switch. External connections by user. Small size. M: For electromedical applications Product List TYPE L1 CX CY FTA-3Z 3 Amp 1,8 mH 100 nF 3,3 nF 254 0,45 mA FASTON 6,3mm 64 FTA-6Z 6 Amp 0,7 mH 100 nF 3,3 nF 254 0,45 mA FASTON 6,3mm 64 Insertion Loss 280 HOUSING LCURRENT CONNECTION WEIGHT ±g I FTC Single - Phase Filters Chassis Panel with Fused IEC Connector + Switch High Attenuation Filter (1-6A) Electrical schematics IEC connector filter General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. (2500Vac for M version) L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Compact filter with IEC connector, fuses and switch. High performance single stage filter. ZM: For electromedical applications. ZC: With earth inductor for high immunity level. Insertion Loss Product List TYPE FTC-1Z FTC-2Z FTC-4Z FTC-6Z FTC-1ZC FTC-2ZC FTC-4ZC FTC-6ZC FTC-1ZM FTC-2ZM FTC-4ZM FTC-6ZM I L1 1 Amp 2 Amp 4 Amp 6 Amp 1 Amp 2 Amp 4 Amp 6 Amp 1 Amp 2 Amp 4 Amp 6 Amp 7,5 mH 2 mH 1 mH 0,45 mH 7,5 mH 2 mH 1 mH 0,45 mH 7,5 mH 2 mH 1 mH 0,45 mH CX CY HOUSING LCURRENT 220 nF 2,2 nF 249 0,21mA 220 nF 2,2 nF 249 0,21mA 220 nF - 249 5µA CONNECTION FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm WEIGHT ±g 250 230 220 210 265 250 235 220 240 220 210 200 281 Single - Phase Filters FTCV Chassis Panel with Fused IEC Connector + Switch + Voltage Selector Filter (1-6A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. (2500Vac for M version) L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. IEC connector filter Compact filter with IEC connector, fuses and switch. With voltage selector. ZM: For electromedical applications. ZC: With earth inductor for high immunity level. Product List TYPE FTCV-1Z FTCV-3Z FTCV-6Z FTCV-1ZC FTCV-3ZC FTCV-6ZC FTCV-1ZM FTCV-3ZM FTCV-6ZM I L1 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 7,5 mH 2 mH 0,45 mH 7,5 mH 2 mH 0,45 mH 7,5 mH 2 mH 0,45 mH Insertion Loss 282 CX CY HOUSING LCURRENT CONNECTION 220 nF 3,3 nF 251 0,32mA 220 nF 3,3 nF 251 0,32mA 220 nF - 251 253 5µA FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm WEIGHT ±g 210 205 200 210 205 200 210 205 200 FTN Single - Phase Filters Chassis Panel with Fused IEC Connector + Switch Filter (1-6A) Electrical schematics General Specifications Maximum operating voltage: 250Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 1800Vac 2s. (2500Vac for M version) L-›N: 1700 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. IEC connector filter With IEC connector, fuses and switch. General purpose filter. M: For electromedical applications. Product List TYPE FTN-1Z FTN-3Z FTN-6Z FTN-1ZM FTN-3ZM FTN-6ZM I L1 1 Amp 3 Amp 6 Amp 1 Amp 3 Amp 6 Amp 2 mH 1,3 mH 0,8 mH 2 mH 1,3 mH 0,8 mH CX CY HOUSING LCURRENT 100 nF 2,2 nF 250 0,21mA 100 nF - 250 241 5µA CONNECTION FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm WEIGHT ±g 110 110 110 110 110 110 Insertion Loss 283 Three - Phase Filters FVDT Three-Phase Filters for Frequency Converters without Neutral (6-900A) Electrical schematics General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. Li-›Lj: 2250 Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2. Three phase double stage Double stage three phase filter. High performance for frequency inverters. High current. High voltage versions are available Product List TYPE FVDT-007B I@50ºC 7A L CX/CX’/CX’’ 4,91 mH 1/1,5/1,5 µF CY/CY’ R/R’ (MΩ) -/1,5 µF 1/0.68 M FVDT-007X FVDT-016B 16 A 4,4 mH 2,2/2,2/1,5 µF -/1,5 µF 1/0.68 M 30 A 1,94 mH 2,2 µF -/2,2 µF 1/0.68 M 42 A 1,5 mH 2,2 µF -/2,2 µF 1/0.68 M 55A 1,08 mH 307 150 mA 15 mA 307 158 mA 16 mA 2,2 µF 0,1/2,2 µF 1/0.68 M 310 158 mA 16 mA 311 75 A 0,85 mH 4mm2 1200 4mm2 + AWG18 1200 4mm2 1700 4mm2 + AWG11 1700 10mm2 1900 10mm2 + AWG9 1900 10mm2 2000 10mm2 + AWG9 2000 16mm2 2200 16mm2 + AWG6 2200 2,2 µF 0,1/2,2 µF 1/0.68 M 310 158 mA 16 mA 25 mm2 4000 2,2 µF 0,1/2,2 µF 1/0.68 M 310 153 mA 15,4 mA 50 mm2 5800 FVDT-130BE 130 A 320µH 4,4/4,4/2,2 µF 0,1/2,2 µF 1/0.68 M 310 167 mA 15,9 mA 50 mm2 6600 160µH 4,4/4,4/2,2 µF 0,1/2,2 µF 1/0.68 M 310 167 mA 15,9 mA 50 mm2 7000 FVDT-100BE 100A FVDT-150BE 150A 284 92 mA 8,8 mA 308 FVDT-055X FVDT-075B 303 308 FVDT-042X FVDT-055B 88 mA 8,8 mA 304 FVDT-030X FVDT-042B 301 302 FVDT-016X FVDT-030B Max. Max. Ifug mA WEIGHT HOUSING Ifug mA CONNECTION 520V ±g IEC 950 50Hz 800µH Three-Phase Filters for Frequency Converters without Neutral (6-900A) Insertion Loss Three - Phase Filters FVDT 285 Three - Phase Filters FVDT Three-Phase Filters for Frequency Converters without Neutral (6-900A) Electrical schematics General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s Li-›Lj: 2250 Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2. Three phase double stage Double stage ultra compact three phase filter. High performance for frequency inverters. Product List Max. Max. R/R’ Ifug mA CONNECTION WEIGHT TYPE L CX/CX’/CX’’ CY/CY’ HOUSING Ifug mA (MΩ) 520V Bus Bar ±g IEC 950 50Hz FVDT-150WE 150 A 160 µH 4,4/4,4/2,2µF 0,1/2,2 µF 1/0.68 M 313 167 mA 15,9 mA 20X3 Ø8,5 23,5+10 7500 I@ 50ºC FVDT-180WE 180 A 160 µH 4,4/4,4/2,2µF 0,1/2,2 µF 1/0.68 M 313 167 mA 15,9 mA 20X3 Ø8,5 23,5+10 8300 FVDT-280WE 280 A 160 µH 4,4/4,4/2,2µF 0,1/2,2 µF 1/0.68 M 313 167 mA 15,9 mA 25X5 Ø10,5 18,5+15 9500 FVDT-400W 400 A 150 µH 2,2/4,4/4,4µF 0,1/2,2 µF 1/0.68 M 315 189,7 mA 18,3 mA 30X5 Ø11 25+15 14400 FVDT-660W 660 A 110 µH 2,2/4,4/4,4µF 0,1/2,2 µF 1/0.68 M 315 189,7 mA 18,3 mA 30X10 Ø11 25+15 16800 FVDT-900W 900 A 110 µH 2,2/4,4/4,4µF 0,1/2,2 µF 1/0.68 M 315 189,7 mA 18,3 mA 40X10 Ø14 30+20 20000 FVDT-150BE 150 A 160 µH 4,4/4,4/2,2 µF 0,1 / 2,2 µF 1 / 0,68 M 310 167 mA 15,9 mA 7000 Insertion Loss 286 50mm2 FVSB Three - Phase Filters Three-Phase Filters One Stage Filter (7-180A) Electrical schematics General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. Li-Lj: 2250 Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d). Flammability class: UL 94 V2. Three phase single stage For industrial equipments. Easy to install. Compact size. Product List R (MΩ) Max. Max. CONNECTION WEIGHT Ifug mA Ifug mA TRM.Block ±g IEC 950 520V 50Hz I@ 50ºC L CX/CX’ FVSB-007B 7 Amp 3,9 mH 1 µF 470 nF 1MΩ 38 mA 3,7 mA 4mm2 450 FVSB-016B 16 Amp 900 µH 2,2 µF 470 nF 1MΩ 39 mA 3,7 mA 4mm2 650 FVSB-030B 30 Amp 700 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 6mm2 1000 FVSB-042B 42 Amp 500 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 10mm2 1100 FVSB-055B 55 Amp 360 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 16mm2 1250 FVSB-075B 75 Amp 150 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 25mm2 2000 FVSB-100B 100 Amp 170 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 50mm2 3100 FVSB-130B 130 Amp 75 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 50mm2 3200 FVSB-180B 180 Amp 75 µH 4,4/2,2 µF 470 nF 1MΩ 44 mA 4 mA 90mm2 4550 TYPE CY 287 FVSB Three - Phase Filters Three-Phase Filters One Stage Filter (7-180A) A B C D E F G H Insertion Loss 288 7A 190 70 40 160 180 20 4,5 M5 16A 250 70 45 220 235 25 5,4 M5 30A 270 85 60 240 255 30 5,4 M5 42A 310 85 60 280 295 30 5,4 M6 55A 310 90 60 280 295 30 5,4 M6 75A 100A 130A 270 270 270 140 150 150 85 90 90 240 240 240 255 255 255 60 65 65 6,5 6,5 6,5 M6 M10 M10 180A 380 170 120 350 365 102 6,5 M10 Three-Phase Filters For Frequency Converters without Neutral (6-28A) Electrical schematics Three - Phase Filters FVDT-D General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s Li-›Lj: 2250 Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2. Three phase double stage Double stage three phase filter. Low leakage current. Product List TYPE I@ 50ºC FVDT-005DB 5 Amp FVDT-005DX FVDT-008DB 8 Amp FVDT-008DX FVDT-016DB 16 Amp FVDT-016DX FVDT-028DB 28 Amp FVDT-028DX L CX CY R/R’ 10 mH 1 µF 15 nF 1 MΩ 5,8 mH 1 µF 15 nF 1 MΩ 3,7 mH 1 µF 15 nF 1 MΩ 2,9 mH 1 µF 15 nF 1 MΩ Max. Max. HOUSING Ifug mA Ifug mA IEC 950 400V 50Hz 305 3,2 mA 0,28 mA 306 305 3,2 mA 0,28 mA 306 303 3,2 mA 0,28 mA 304 303 3,2 mA 0,28 mA 304 CONNECTION WEIGHT ±g 4mm2 700 4mm2 + AWG18 WIRE 700 4mm2 700 4mm2 + AWG18 WIRE 700 4mm2 1000 4mm2 + AWG11 WIRE 1000 6mm2 1900 6mm2 + AWG9 WIRE 1900 Insertion Loss 289 Three - Phase Filters FVST Three-Phase Filters For Frequency Converters without Neutral (6-660A) Electrical schematics General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. Li-Lj: 2250 Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d). Flammability class: UL 94 V2. Three phase one stage Single stage three phase filter. For fast switching applications. High current. Some high voltaje version are available. Product List TYPE FVST-006 FVST-008 FVST-016 FVST-025 FVST-036 FVST-050 FVST-064 FVST-080 FVST-110 FVST-180 FVST-250 FVST-350 FVST-450 FVST-660 I@ 50ºC L CX/CX’ CY/CY’ R/R’ (MΩ) 6 Amp 8 Amp 16 Amp 25 Amp 36 Amp 50 Amp 64 Amp 80 Amp 110 Amp 180 Amp 250 Amp 350 Amp 450 Amp 660 Amp 7 mH 5,5 mH 4 mH 2,9 mH 2,2 mH 1 mH 0,55 mH 1 mH 0,7 mH 0,4 mH 0,13 mH 0,13 mH 0,15 mH 0,14 mH 1/- µF 1/- µF 2,2/- µF 4,4µF 4,4µF 4,4µF 4,4µF 6,6µF 6,6µF 6,6µF 11µF 11/22 µF 11/22 µF 11/22 µF /-/470/- nF /-/470/- nF /-/470/- nF 10nF/47nF/1µF 10nF/47nF/1µF 10nF/100nF/1µF 10nF/100nF/1µF 47nF/100nF/1µF 47nF/100nF/1µF 47nF/100nF/1µF 100nF/100nF/1µF 100nF/100nF/1µF 100nF/100nF/1µF 100nF/100nF/1µF 470/10MΩ 470/10MΩ 1M/10MΩ 1MΩ 1MΩ 1MΩ 1MΩ 1MΩ 1MΩ 1MΩ 1MW/470KΩ 1MW/470KΩ 1MW/220KΩ 1MW/470KΩ Insertion Loss 290 Max. Max. HOUSING Ifug mA Ifug mA IEC 950 400V 50Hz 301 38 mA 3,7 mA 303 39 mA 3,7 mA 303 44 mA 4 mA 309 190 mA 17,6 mA 309 190 mA 17,6 mA 309 190 mA 17,6 mA 309 190 mA 17,6 mA 310 226 mA 18,7 mA 310 226 mA 18,7 mA 312 226 mA 18,7 mA 315 255 mA 19,4 mA 315 262 mA 19,6 mA 315 262 mA 19,6 mA 315 262 mA 19,6 mA CONNECTION Hx0 Ø M+N WEIGHT ±g 4mm2 4mm2 4mm2 6mm2 10mm2 10mm2 25mm2 25mm2 50mm2 M10 SCREW 25X5 Ø11 25+15* 25X5 Ø11 25+15* 30X5 Ø11 25+15* 30X10 Ø11 25+15* 700 1600 1600 2400 2400 2400 2400 4500 4500 - HCWMGF Three-Phase Filters For Wind Mills Applications (150-2500A) Three - Phase Filters General Specifications - Maximum operating voltage: 720 Vac - Operating frequency: DC – 60Hz - Hipot test voltage: L/N-›·PE: 3100 Vdc 2s Li-Lj: 3000 Vdc 2s - Flammability class: UL 94 V2 Three Phase Filters High-Power filters for rated currents up to 2500A Attenuation loss for Class A compliance. Protective cover for busbar optional High voltage for IT networks HCWMGFR-XXXXHV-LL Low Leakage Current version Applications High power inverters, converters, UPS and renewable energy equipments Electrical schematic Product List TYPE Leakage Power Rated Current Power Current Losses (A) @ 50 ºc (kW) (mA) (W) Busbar Connections Weight Housing Connections Input/Output (Kg) (mm) HCWMGF-150HV 150 110 <6 24 M10 Screw 6,5 65 HCWMGF-180HV 180 132 <6 34 M10 Screw 6,5 65 HCWMGF-250HV 250 200 <6 49 M10 Screw 7 66 HCWMGF-320HV 320 250 <6 19 6 x 25 10,5 67 HCWMGF-400HV 400 315 <6 29 6 x 25 10,5 67 HCWMGF-600HV 600 500 <6 44 8 x 25 11 68 HCWMGF-800HV 800 630 <6 39 8 x 40 18 69 HCWMGF-1000HV 1000 710 <6 60 8 x 40 18 69 HCWMGF-1300HV 1300 1000 <6 100 10 x 60 27 70 HCWMGF-1600HV 1600 1320 <6 131 10 x 60 27 70 HCWMGF-2500HV 2500 2000 <6 300 15 x 70 55 71 25 x 6mm, ǩ 10.5 25 x 6mm, ǩ 10.5 25 x 8mm, ǩ 10.5 40 x 8mm, ǩ 14 40 x 8mm, ǩ 14 60 x 10mm, ǩ 14 60 x 10mm, ǩ 14 70 x 15mm, ǩ 14 291 HCWMGF Three - Phase Filters Three-Phase Filters For Wind Mills Applications (150-2500A) 150-180A 800-1000-1300A 292 250-600A 1600-2500A DTRF Three - Phase Filters Three Phase Filter for Industrial Applications (20-50A) General Specifications Maximum operating voltage: 520Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 2000 Vac 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Applications Servo drives Three phase power supplies Medical equipment Features DIN guide optional for rail mounted equipment (DIN ended reference) LL models for very low leakage current NL models for better attenuation. Electrical schematics Product List Rated Current (A) @ 50 ºc Leakage Current (mA) Power Losses (W) DTRF-020LL 20 <0,4 5,4 DTRF-030LL 30 <0,4 6,2 DTRF-050LL 50 <0,4 9,4 DTRF-020NL 20 <2,5 5,4 DTRF-030NL 30 <2,5 6,2 DTRF-050NL 50 <2,5 9,4 TYPE Connections Terminal block 4-6 mm2 / AWG 12-10 Terminal block 8-10 mm2 / AWG 8-7 Terminal block 16-20 mm2 / AWG 5-4 Terminal block 4-6 mm2 / AWG 12-10 Terminal block 8-10 mm2 / AWG 8-7 Terminal block 16-20 mm2 / AWG 5-4 Weight (Kg) Housing 0,56 61,63 DIN 0,58 61,63 DIN 0,98 62,64 DIN 0,56 61,63 DIN 0,58 61,63 DIN 0,98 62,64 DIN 293 DTRF Three - Phase Filters Three Phase Filter for Industrial Applications (20-50A) 294 20A LL 20A NL 30/50A LL 30/50A NL FVTC Three - Phase Filters Three Phase One Stage Filter for Industrial Applications (10-1000A) General Specifications Maximum operating voltage: 520 Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 3000 Vdc 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Electrical schematic Three Phase One stage For industrial motor drive applications Protective covers as optional accessory Compact size Product List TYPE Typical drive Rated Current Leakage Current Power rating (A) @ 50 ºc 400VAC/50Hz (mA) (KW) Power Losses (W) FVTC-010B 10 5.5 26.4 2.4 FVTC-020B 20 11 26.4 4.1 FVTC-035B 35 22 29.4 6.8 FVTC-050B 50 30 29.4 12.8 FVTC-065B 65 37 29.4 13.5 FVTC-080B 80 45 29.4 13.5 FVTC-100B 100 55 29.4 17.1 FVTC-150P 150 75 59.5 7.5 FVTC-200P 200 110 59.5 13.2 FVTC-250P 250 132 59.5 20.6 FVTC-320P 320 160 59.5 12.2 FVTC-400P 400 220 59.5 19.2 FVTC-600P 600 315 59.5 35.6 FVTC-800P 800 400 59.5 51.8 FVTC-1000P 1000 560 59.5 81 Connections Terminal block 6 mm2 / AWG 8 Terminal block 10 mm2 / AWG 6 Terminal block 16 mm2 / AWG 4 Terminal block 25 mm2 / AWG 2 Terminal block 25 mm2 / AWG 2 Terminal block 50mm2 / AWG 0 Terminal block 95 mm2 / AWG 000 Bus Bar 20x3,ø9 Bus Bar 20x3,ø9 Bus Bar 20x3,ø9 Bus Bar 25x6,ø11 Bus Bar 25x6,ø11 Bus Bar 25x6,ø11 Bus Bar 40x8,ø13.5 Bus Bar 40x8,ø13.5 Weight (Kg) 0.5 0.6 0.8 1.3 1.5 2.5 3 7 7 7 7.5 7.5 8 18 18 295 Three - Phase Filters FVTC Three Phase One Stage Filter for Industrial Applications (10-1000A) 10 A 20 A 35 A 50 A 65 A 80 A 100 A 150 A 200 A 250 A 320 A 400 A 600 A 800 A 1000 A A B C D E F G H V W X Y Z 296 150 150 160 170 170 200 230 300 58 58 68 80 80 90 90 86 58 58 70 85 85 95 95 200 120 120 130 140 140 170 200 240 132.5 132.5 142.5 152.5 152.5 182.5 212.5 275 42 42 50 65 65 75 75 165 4.5 4.5 5.5 5.5 5.5 5.5 5.5 Ø11 M4 M4 M6 M6 M6 M8 M8 M10 20 3 10 37 Ø9 300 86 200 240 275 165 Ø11 M10 20 3 10 37 Ø9 300 86 200 240 275 165 Ø11 M10 20 3 10 37 Ø9 300 95 200 240 275 165 Ø11 M10 25 6 12,5 37 Ø11 300 95 200 240 275 165 Ø11 M10 25 6 12,5 37 Ø11 300 370 370 95 125 125 200 190 190 240 310 310 275 345 345 165 155 155 Ø11 Ø11 Ø11 M10 M12 M12 25 40 40 8 8 8 12,5 20 20 37 47 47 Ø11 Ø13.5 Ø13.5 Three Phase One Stage Filter for Industrial Applications (10-1000A) 10 & 20A 35 65A 80 & 100A 150 1000A Three - Phase Filters FVTC 297 Three - Phase Filters FVRB Three Phase One Stage Filter for Regenerative Converters (35-300A) General Specifications Maximum operating voltage: 520 Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 3000 Vdc 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Three Phase One stage For Regeneration units Good saturation resistance Book style with compact size and easy to install. Electrical schematic Product List TYPE 298 Typical drive Leakage Current Rated Current Power rating 400VAC/50Hz (mA) (A) @ 50 ºc (KW) Power Losses (W) FVRB-035B 35 22 48.9 11.8 FVRB-050B 50 30 66.1 18 FVRB-080B 80 45 71.5 25.9 FVRB-110B 110 55 71.5 32.7 FVRB-150B 150 75 71.5 50.6 FVRB-200B 200 110 71.5 67.2 FVRB-230B 230 132 71.5 36.5 FVRB-300P 300 160 71.5 54.0 Connections Terminal block 10 mm2 / AWG 6 Terminal block 16 mm2 / AWG 4 Terminal block 25 mm2 / AWG 2 Terminal block 50 mm2 / AWG 0 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Bus Bar 150 mm2 / AWG0000 Weight (Kg) 2.5 3.5 5.5 6 9 9.5 10 12 Three Phase One Stage Filter for Regenerative Converters (35-300A) A B C D E F G H 35 A 50 A 80 A 110 A 150 A 200 A 230 A 300 A 335 150 60 305 320 35 6.5 M5 329 185 80 300 314 55 6.5 M6 379 220 90 350 364 65 6.5 M10 379 220 90 350 364 65 6.5 M10 438 240 110 400 413 80 6.5 M10 438 240 110 400 413 80 6.5 M10 438 240 110 400 413 80 6.5 M10 440 200 200 400 420 160 6.5 M12 BUS BAR 25x5 mm Three - Phase Filters FVRB 299 Three - Phase Filters FVRB 300 Three Phase One Stage Filter for Regenerative Converters (35-300A) Three Phase Double Stage Filter for Industrial Applications (7-250A) General Specifications Maximum operating voltage: 520 / 720 Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 3000 Vdc 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Three - Phase Filters FVDB Three Phase One stage For three phase inverters and power drive system Book style with compact size and easy to install. High Voltage version is available Electrical schematic Product List Rated Current (A) @ 50 ºc Typical drive Power rating Nor./HV(KW) Leakage Current 440VAC/50Hz (mA) Power Losses (W) 7 4 / 5.5 16.5 9 16 7.5 / 11 18.3 20 30 15 / 22 24.2 21 42 22 / 30 25.8 30 55 30 / 45 25.8 30 75 37 / 55 25.8 24 100 55 / 90 25.8 51 130 75 / 100 30 50 FVDB-180B 180 90 30 73 FVDB-250B 250 132 30 79 TYPE FVDB-007B FVDB-007BHV FVDB-016B FVDB-016BHV FVDB-030B FVDB-030BHV FVDB-042B FVDB-042BHV FVDB-055B FVDB-055BHV FVDB-075B FVDB-075BHV FVDB-100B FVDB-100BHV FVDB-130B FVDB-130BHV Connections Terminal block 4 mm2 / AWG 10 Terminal block 4 mm2 / AWG 10 Terminal block 10 mm2 / AWG 6 Terminal block 16 mm2 / AWG 4 Terminal block 25 mm2 / AWG 2 Terminal block 25mm2 / AWG 2 Terminal block 50 mm2 / AWG 0 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Weight (Kg) 1 1.5 2 2.5 3 4 5.5 7 11 12 301 Three - Phase Filters FVDB Three Phase Double Stage Filter for Industrial Applications (7-250A) A B C D E F G H 302 7A 16 A 30 A 42 A 55 A 75 A 100 A 130 A 180 A 250 A 255 126 50 225 240 25 6.5 M5 305 142 55 275 290 30 6.5 M5 335 150 60 305 320 35 6.5 M6 329 185 70 300 314 45 6.5 M6 329 185 80 300 314 55 6.5 M6 329 220 80 300 314 55 6.5 M6 379 220 90 350 364 65 6.5 M10 439 240 110 400 414 80 6.5 M10 438 240 110 400 413 80 6.5 M10 478 240 110 440 453 80 6.5 M10 Three Phase Double Stage Filter for Industrial Applications (7-250A) Three - Phase Filters FVDB 303 FOR FREQUENCY INVERTERS Three - Phase Filters Introduction Features Three phase filter for frequency inverters/PDS. “Foot-print” mounting. High attenuation properties. Small and ergonomic size. Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. L-›N: 2250 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Introduction to Inverter Filters PREMO has developed a very comprehensive INVERTER EMC FILTER family including two specific sub families: t'PPU1SJOUåMUFSTGPSJOTUBMMBUJPOCFMPXUIF*OWFSUFSBOE t'JMUFSTGPS-*'541 Each family is designed to meet the specific ElectroMagnetic Compatibility Standard for each product. PREMO has the expertise and equipment to design customer specific EMC Filters; both in Electrical and Mechanical design. In this Filter family, Premo Manufacture EMC Filters both Single-Phase and Three-Phase up to 900 Amps and voltages of 250V, 520V and 720V. Inverter Connection Information A. B. C. D. E. F. G. H. I. 304 Ground all metallic conductive parts using suitable cables to a central point. Ensure that paint is removed from metalwork to provide a good earth contact. The EMC Filter should be placed as close as possible to the inverter case. Separate the motor cables and supply cables as much as possible. Use shielded cable (with copper braid and earth wire) from the filter to the motor. Connect the shielding and earth at the both ends. If required, use Output Ferrites in the motor cable – place the ferrites as close to the inverter as possible. Wind the motor cables around the ferrite (as least twice) but do not wind the shield or earth wires around the ferrite. Follow the Inverter Manufacturers Installation instructions, making sure that earth is as good as possible. Separate the motor and control cables as much as posible. Use copper braid to connect the Electrical Control Panel with its Door, to provide a good earth connection. Connect the motor frame direct to earth. FOR FREQUENCY INVERTERS Three - Phase Filters Introduction 305 P-0999 Three - Phase Filters Three-Phase Filters for Frequency Converters (36-60A) Three phase filters specially designed for frequency inverters. General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. Li-Lj: 2250 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Electrical schematics Product List Type I CX/CX’ CY/CY’ R/R’ Housing Max. Ileak mA Max. Ileak mA Weight Connection IEC 950 520V 50Hz ±g X -0999-005 36 Amp 2,5 mH 2,2/- µF 100/330 nF 1 MΩ 309 40 mA 3,6 mA 10mm2 2400 X -0999-006 55 Amp 1,8 mH 2,2/- µF 100/470 nF 1 MΩ 310 54,8 mA 5 mA 16mm2 5700 X -0999-007 16 Amp 4,4 mH 1/-2,2 µF 100/330 nF 1 MΩ 309 40,7 mA 3,7 mA 4mm2 1900 X -0999-014 60 Amp 710µH 2,2/- µF 100/2,2µF 1000/680 KΩ 310 158 mA 15,9 mA 25mm2 7000 Insertion Loss 306 L FEDC DC Filters EMC DC Filter for PV applications Electrical schematic General Specifications Maximum operating voltage: 1200 Vdc max. Operating frequency: DC. Hi-pot test voltage: L/N-›PE: 3600Vdc 2s. Li-Lj: 3000 Vdc 2s. Application class: HMF Acc.TO DIN 40040 (-40ºC/+100ºC/95% RH, 30d). Flammability class: UL 94 V2. Single stage For PV (Photovoltaic) Inverters. For Other DC applications. According to UL1283 and EN 60939. * FEDC- xxxxx -LL – Without Cy Capacitors. Product List TYPE FEDC-25B FEDC-25B-LL FEDC-50B FEDC-50B-LL FEDC-75B FEDC-75B-LL FEDC-100B FEDC-100B-LL FEDC-150B FEDC-150B-LL FEDC-250P FEDC-250P-LL FEDC-400P FEDC-400P-LL FEDC-600P FEDC-600P-LL FEDC-800P FEDC-800P-LL FEDC-1000P FEDC-1000P-LL FEDC-1500P FEDC-1500P-LL Rated Current (A) @ 50 ºc Typical inverter AC Power rating (KW) Power Losses (W) @ 25°C 25 10 8 50 20 17 75 30 18 100 40 22 150 60 31 250 100 10 400 150 16 600 250 29 800 350 26 1000 400 40 1500 500 45 Connection Terminal block 6 mm2 / AWG 8 Terminal block 16 mm2 / AWG 4 Terminal block 25 mm2 / AWG 2 Terminal block 50 mm2 / AWG 0 Terminal block 95 mm2 / AWG 00 Bus Bar 20x5,Ø9 Bus Bar 25x6,Ø11 Bus Bar 25x8,Ø11 Bus Bar 40x8,Ø14 Bus Bar 40x8,Ø14 Bus Bar 60x10,Ø14 Weight (Kg) 1.0 1.7 1.8 2.8 5.0 5.2 6.3 6.6 9.5 9.6 15.0 307 FEDC DC Filters EMC DC Filter for PV applications 308 Mechanical Dimensions (mm) FEDC Mechanical Dimensions (mm) A B C D E1 E2 F1 F2 G H J S T U V W X Y Z 25 A 50 A 75 A 100 A 150 A 250 A 400 A 600 A 800 A 1000 A 1500 A 170 80 65 140 152,5 200 95 80 170 182,5 200 95 80 170 182,5 220 125 95 190 202,5 250 140 115 220 202,5 45 60 5,5 1 M5 60 75 5,5 1,5 M6 60 75 5,5 1,5 M6 80 100 5,5 1,5 M8 100 120 5,5 2 M10 300 180 110 130 130 110 155 300 190 110 140 130 110 165 300 190 110 140 130 110 165 300 200 140 150 130 110 175 300 200 140 150 130 110 175 300 200 150 150 130 110 175 Ø12 2 M10 Ø12 2 M10 Ø12 2 M10 Ø12 3 M12 Ø12 3 M12 70 20 5 15 58 Ø9 70 25 6 15 58 Ø11 70 25 8 15 58 Ø11 70 40 8 20 65 Ø14 70 40 8 20 65 Ø14 Ø12 3 M12 43 26 70 60 10 17 100 Ø14 DC Filters EMC DC Filter for PV applications Insertion Loss 309 FVTO-IV Three Phase + Neutral Line Filters Three-Phase Filters for Frequency Converters without Neutral (7-180A) Electrical schematic General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. L-›N: 1300 Vdc 2s. Li-›Lj: 2250 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Three Phase + Neutral Filters, Double Stage Three phase + neutral filter for frecuency inverters/PDS. “Foot-print” mounting. High attenuation properties. Small and ergonomic size. Product List Type FVTO6IV FVTO10IV FVTO12IV FVTO20IV FVTO20IVB FVTO30IV FVTO40IV FVTO60IV FVTO60IVB FVTO80IV FVTO80IVB FVTO100IV FVTO150IV FVTO180IV 310 I 6 Amp 10 Amp 12 Amp 20 Amp 20 Amp 30 Amp 40 Amp 60 Amp 63 Amp 80 Amp 80 Amp 100 Amp 150 Amp 180 Amp L CX/CX’/CX’’ CY/CY’ R/R’ 5 mH 1 µF 47nF/470nF /-/680KΩ/680K Ω/1MΩ 5 mH 1 µF 47nF/470nF 680KΩ/680KΩ/-/5 mH 2,2µF 47nF/470nF /-/680KΩ/680KΩ/1MΩ 2 mH 2,2µF 47nF/1µF 680KΩ/680KΩ/-/2 mH 2,2µF 47nF/1µF 680KΩ/680KΩ/-/1,2 mH 2,2µF 150nF/220nF 680KΩ/-/-/1,2 mH 2,2µF 150nF/220nF 680KΩ/-/-/1,5 mH 2,2µF 330nF/2,2µF 680KΩ/-/-/330KΩ 1,5 mH 2,2µF 330nF/2,2µF 680KΩ/-/-/330KΩ 170 µH 2,2µF 150nF/220nF 680KΩ/-/-/170 µH 2,2µF 150nF/220nF 680KΩ/-/-/170 µH 2,2µF 150nF/220nF 680KΩ/-/-/160 µH 4,4/4,4/2,2µF 470nF/470nF /-/-/1MΩ/330KΩ 160 µH 4,4/4,4/2,2µF 100nF/2,2µF /-/-/1MΩ/680KΩ Max. Max. CONNECTION HOUSING Ifug mA Ifug mA Hx0 Ø M+N IEC 950 400V 50Hz 406 405 406 409 407 408 408 408 411 413 310 413 413 413 47,6 mA 47,6 mA 51,8 mA 97,6 mA 97,6 mA 37,8 mA 37,8 mA 187 mA 187 mA 16 mA 16 mA 16 mA 38,9 mA 190 mA 4,5 mA 4,5 mA 4,7 mA 9,28 mA 9,28mA 3,4 mA 3,4 mA 19,4 mA 19,4 mA 1,4 mA 1,4 mA 1,4 mA 3,4 mA 18,4 mA 6mm2 M4 SCREW 6mm2 M6 SCREW 4mm2 10mm2 10mm2 10mm2 25mm2 M10 SCREW 25mm2 M10 SCREW M10 SCREW M10 SCREW Three-Phase Filters for Frequency Converters without Neutral (7-180A) Insertion Loss Three Phase + Neutral Line Filters FVTO-IV 311 PFT Three Phase + Neutral Line Filters Three-Phase + Neutral Filters for General Use (3-150A) Electrical schematics General Specifications Maximum operating voltage: 520Vac. Operating frequency: DC - 60Hz. Hipot test voltage: L/N-›PE: 3000Vdc 2s. L-›N: 1300 Vdc 2s Li-›Lj: 2250 Vdc 2s. Application class: HPF Acc. TO DIN 40040 (-25ºC/+85ºC/95% RH, 30d). Flammability class: UL 94 V2. Three phase + Neutral filters Single stage three phase + neutral filter. For switching applications. Product List Type I@40ºC PFT-3Z 3 Amp PFT-6Z 6 Amp PFT-10Z 10 Amp PFT-20Z 20 Amp PFT-20W PFT-25B 25 Amp PFT-25W PFT-36B 36 Amp PFT-36W PFT-50B 50 Amp PFT-50W PFT-65B 65 Amp PFT-65W PFT-80B 80 Amp PFT-80W PFT-110B 110 Amp PFT-110W PFT-150B 150 Amp PFT-150W 312 L1 CX/CX’ CY R 1 mH 0,45 mH 0,2 mH 0,2 mH 0,2 mH 1,3 mH 0,1 µF 0,1 µF 0,1 µF 0,1 µF 0,1 µF 2,2 µF 20 nF -4,7 nF -4,7 nF -22 nF -22 nF 15 nF 110 KΩ 1 mH 2,2 µF 15 nF 110 KΩ 0,55 mH 2,2µF/100 nF 15 nF 1MΩ 0,36 mH 2,2 µF 1MΩ 0,5 mH 1 µF 0,25 mH 1 µF 0,25 mH 2,2 µF 22 nF 22 nF 470kΩ 470kΩ 22 nF 470kΩ 22 nF 110KΩ Max. Max. WEIGHT HOUSING Ifug mA Ifug mA CONNECTION ±g IEC 950 400V 50Hz 401 401 401 401 402 403 404 403 404 403 404 403 404 410 412 410 412 410 412 485 µA 485 µA 485 µA 1,9 mA 1,9 mA 3,2 mA 43 µA 43 µA 43 µA 191 µA 191 µA 280 µA 3,2 mA 280 µA 3,2 mA 280 µA 4,7 mA 412 µA 4,7 mA 410 µA 4,7 mA 410 µA 4,7 mA 412 µA FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm FASTON 6,3mm M6 SCREW 4mm2 M6 SCREW 6mm2 M6 SCREW 10mm2 M6 SCREW 10mm2 M6 SCREW 25mm2 M10 SCREW 50mm2 M10 SCREW 50mm2 M10 SCREW 220 220 240 240 550 1500 1500 1700 1700 3000 3200 3500 PFT Insertion Loss Three Phase + Neutral Line Filters Three-Phase + Neutral Filters for General Use (3-150A) 313 Three Phase + Neutral Line Filters STF Three-Phase + Neutral Filters for Solar Technology Applications (8-200A) General Specifications Maximum operating voltage: 520 Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 3000 Vdc 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Three Phase + Neutral Filters Single stage Solar technology applications Compact model for saving space Low leakage current Electrical schematic Product List Type 314 Power Rated Current Leakage Current Losses (A) @ 50 ºc (mA) (W) STF-008HV 8 <1 2,7 STF-016HV 16 <1 6 STF-025HV 25 <1 11,6 STF-036HV 36 <1 14,8 STF-064HV 64 <1 18,4 STF-080HV 80 <1 18,9 STF-120HV 120 <1 28,5 STF-160HV 160 <1 30,7 STF-200HV 200 <1 46,8 Connection Terminal block 4 mm2 / AWG 10 Terminal block 4 mm2 / AWG 10 Terminal block 10 mm2 / AWG 6 Terminal block 10 mm2 / AWG 6 Terminal block 25 mm2 / AWG 2 Terminal block 50 mm2 / AWG 0 Terminal block 50 mm2 / AWG 0 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Weight (Kg) Housing 0,8 50 0,8 50 1,3 51 1,6 51 2,7 52 4,1 53 5,9 54 7,9 55 8,5 55 Three-Phase + Neutral Filters for Solar Technology Applications (8-200A) Insertion Loss Three Phase + Neutral Line Filters STF 315 Three Phase + Neutral Line Filters FVNSB Three-Phase + Neutral Filters for Industrial Applications (8-200A) General Specifications Maximum operating voltage: 520 Vac Operating frequency: DC – 60Hz Hipot test voltage: L/N-›PE: 2750 Vdc 2s Li-Lj: 2250 Vdc 2s Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d) Flammability class: UL 94 V2 Three Phase One stage For Industrial machinery units Compact size with Neutral Line Electrical schematic Product List Rated Current (A) @ 50 ºc Leakage Current (mA) Power Losses (W) FVNSB-008B 8 <1 2,7 FVNSB-016B 16 <1 6 FVNSB-025B 25 <1 11,6 FVNSB-036B 36 <1 14,8 FVNSB-064B 64 <1 18,4 FVNSB-080B 80 <1 18,9 FVNSB-120B 120 <1 28,5 FVNSB-160B 160 <1 30,7 FVNSB-200B 200 <1 46,8 Type 316 Connection Terminal block 4 mm2 / AWG 10 Terminal block 4 mm2 / AWG 10 Terminal block 10 mm2 / AWG 6 Terminal block 10 mm2 / AWG 6 Terminal block 25 mm2 / AWG 2 Terminal block 50 mm2 / AWG 0 Terminal block 50 mm2 / AWG 0 Terminal block 95 mm2 / AWG 000 Terminal block 95 mm2 / AWG 000 Weight (Kg) 0,8 0,8 1,3 1,6 2,7 4,1 5,9 7,9 8,5 FVNSB A B C D E F G H Three Phase + Neutral Line Filters Three-Phase + Neutral Filters for Industrial Applications (8-200A) 8A 16 A 25 A 36 A 64 A 80 A 120 A 160 A 200 A 120 143 80 115 80 127.5 6.5 M6 120 143 80 115 80 127.5 6.5 M6 130 153 115 125 90 137.5 6.5 M6 130 153 115 125 90 137.5 6.5 M6 160 153 125 125 100 137.5 6.5 M10 230 163 125 135 120 147.5 6.5 M10 250 170 140 140 200 153.5 6.5 M10 280 170 170 140 230 153.5 6.5 M10 280 170 170 140 230 153.5 6.5 M10 317 Three Phase + Neutral Line Filters FVNSB 318 Three-Phase + Neutral Filters for Industrial Applications (8-200A) 64 120A 160 200A N-X General Specifications Output Ferrites (N-X) are especially effective in reducing electromagnetic interference from the motor cable, as they introduce an impedance between the Inverter and the motor. Output ferrites are particularly useful in reducing electrical noise in the frequency range 5 to 20 MHz, as there is no other suitable noise suppression means in this frequency range. Output ferrites should be placed around the cable between the Inverter and Motor, as near as possible to the Inverter. The cable (excluding earth wires and shielding) should pass through the ferrite at least twice. Output Ferrites Inverter Output Ferrites 319 N-X Output Ferrites Inverter Output Ferrites 320 Product List Type N1 N2 N3 Number of turns 2 3 4 2 3 4 2 3 4 Wire section 10mm2 6mm2 4mm2 16mm2 10mm2 6mm2 50mm2 35mm2 25mm2 Inductance 38µH 86µH 153µH 44µH 90µH 176µH 25,6µH 57,6µH 102µH Max Current 60A 45A 30A 90A 65A 46A 150A 100A 75A H 50mm 65mm 110mm L 86mm 105mm 150mm G 24mm 25mm 50mm D 21mm 28mm 50mm d 48mm 64mm 108mm F 4mm 4mm 5mm X 70mm 125mm Y 11,5mm 89mm 12,5mm 30mm FOVT dV/dt Output Filters DV/DT Output Filters (8-70A) General Specifications Maximum operating voltage: 550V±15. Operating frequency: 50-60Hz. Hipot test voltaje: L/N -> PE: 3000Vdc 2s. Li-Lj: 2250Vdc 2s. Application class: HMF Acc. TO DIN 40040 (-25ºC/+100ºC/95% RH, 30d). Flammability class: UL 94 V2. Inverter Switching Frequency: 4-16kHz. Max. Length of motor cable: 50m. Electrical schematics dV/dT Output Filter Output 3 phase filter for inverter. Minimizes Frequency Inverter dV/dT Values. For long motor cables. Increases motor life. Reduces motor heating. Product List Type I@50ºC L CX CY L leakage Connection Weight ±g FOVT-008B FOVT-016B 8 Amp 16 Amp 0,2 mH 0,2 mH 4,7 nF 4,7 nF 100 nF 100 nF 258 µA 258 µA 4mm2 4mm2 1600 2200 FOVT-025B FOVT-036B 25 Amp 36 Amp 0,2 mH 0,2 mH 4,7 nF 4,7 nF 100 nF 100 nF 258 µA 258 µA 6mm2 10mm2 4500 5800 FOVT-055B 55 Amp 0,2 mH 10 nF 70 Amp 0,08 mH 10 nF 320 µA 320 µA 16mm2 25mm2 6500 FOVT-070B 100 nF 100 nF 7200 321 FOVT dV/dt Output Filters DV/DT Output Filters (8-70A) Fast switching generated by inverter IGBTs causes high voltage ramps (greater than 4000V/ µs), that may be even higher in the motor windings. The fast switching can also shorten the motor life and limit maximum cable lengths. By using a PREMO EMC dV/dT filter, you can guarantee that the maximum peak voltage will be under 1000V, with a dV/dT value less than 500 V/µs. This voltage peak suppression will also reduce EMI interference from the inverter, will increase its life and improve its performance. FOVT-008B FOVT-016B FOVT-025B FOVT-036B FOVT-055B FOVT-070B 322 A 99 150 231 350 350 380 B 58 56 71 81 81 90 C 105 100 119 149 149 180 D 85 126 151 300 300 320 E 51 85 115 325 325 345 F 95 116 135 110 110 120 G 5,3 5,3 5,3 6,5 6,5 8,5 H M6 M6 M6 M6 M6 M8 FOVT Motor cable length (M) at Inverter switching frequency based on 400VAC, @40°C Continuous Operation Type 4KHz 8KHz FOVT-008B 35 15 FOVT-016B FOVT-025B 35 15 50 25 FOVT-036B 50 25 FOVT-055B 50 25 FOVT-070B 50 25 dV/dt Output Filters DV/DT Output Filters (8-70A) 323 CFT Feedthrough Filters Single Line C-Circuit (10-250A) General Specifications Maximum operating voltage: 250VAC / 400VDC. Operating frequency: DC - 60Hz. Hi-pot test voltage: L/N-›PE: 3000Vdc 2s. Climatic category: HPF (40/085/56) (-40ºC/+85ºC/95% RH, 30d). MTBF: > 0.3 Million Hours@40°C, 230VAC Flammability class: UL 94 V0. Single Line, C Circuit For Telecom, Military and Industrial application. Compact size and easy to install. Electrical schematics Product List Rated Current (A) @40ºC Rated Capacitance @1KHz, 25 ºC Leakage Current 250VAC/ 50Hz (mA) Termination Torque on S (Nm) Mounting Thread Weight (gr) X-10290-013 X-10290-018 10 16 4.7 nF 100 nF 0.5 12.0 M3 M4 0.5 1.2 M10 x 1 M12 x 1 25 35 X-10290-019 X-10290-020 32 63 100 nF 100 nF 12.0 12.0 M4 M6 1.2 2.5 M16 x 1 M16 x 1 35 45 X-10290-021 100 100 nF 12.0 200 100 nF 12.0 5.0 8.0 M20 x 1 M24 x 1 120 X-10290-023 M8 M10 X-10290-022 250 100 nF 12.0 M12 11.0 M31 x 1.5 200 Type 324 140 CFT Feedthrough Filters Single Line C-Circuit (10-250A) Mechanical dimensions (mm) A B C D E F G 10A 16A 32A 63A 100A 200A 250A 19 10 16 13 15 M3 M10 x 1 30 14 18 22 25 M4 M16 x 1 30 14 18 22 25 M4 M16 x 1 30 14 18 26 25 M6 M16 x 1 33 16 32 27 32 M8 M20 x 1 33 19 40 27 38 M10 M24 x 1 42 19 46 41 54 M12 M32 x 1.5 Installation Guide - The torque applied to the screw cannot exceed max level. - Filter metal housing must be well connected to cabinet panel by electrically and make good grounding. - The input & output wires should be separated to avoid noise coupling. - Input wire of filter connection should be short and it will help to minimize radiated interferences. - Make good insulation around the connection part to avoid short circuit. - Further information, please contact PREMO Technical person. 325 CFT Feedthrough Filters Single Line C-Circuit (10-250A) 326 Insertion Loss PIFT Feedthrough Filters Single Line Pi-Circuit (10-63A) General Specifications Maximum operating voltage: 250VAC / 400VDC. Operating frequency: DC - 60Hz. Hi-pot test voltage: L/N-›PE: 3000Vdc 2s. Climatic category: HPF (40/085/56). (-40ºC/+85ºC/95% RH, 30d). MTBF: > 0.3 Million Hours@40°C,230VAC Flammability class: UL 94 V0. Single Line, Pi Circuit For Telecom, Military and Industrial application. Compact size and easy to install. High Current version is available. Electrical schematics Product List Rated Current (A) @40ºC Rated Capacitance @1KHz, 25 ºC Leakage Current 250VAC/ 50Hz (mA) Termination Torque on S (Nm) Mounting Thread Weight (gr) X-10290-014 X-10290-015 10 16 2 x 10 nF 2 x 22 nF 2.4 5.0 M3 M4 0.5 1.2 M12 x 1 M16 x 1 45 70 X-10290-016 X-10290-017 32 63 2 x 47 nF 2 x 470 nF 10.0 100 M4 M6 1.2 2.5 M24 x 1 M32 x 1.5 135 420 Type 327 PIFT Feedthrough Filters Single Line Pi-Circuit (10-63A) Mechanical dimensions (mm) A B C D E F G 10A 16A 32A 63A 66 12 16 17 20 M3 M12 x 1 69 14 18 22 25 M4 M16 x 1 101 14 18 22 25 M4 M16 x 1 118 19 26 41 54 M6 M32 x 1.5 Installation Guide - The torque applied to the screw cannot exceed max level. - Filter metal housing must be well connected to cabinet panel by electrically and make good grounding. - The input & output wires should be separated to avoid noise coupling. - Input wire of filter connection should be short and it will help to minimize radiated interferences. - Make good insulation around the connection part to avoid short circuit. - Further information, please contact PREMO Technical person. 328 PIFT Insertion Loss Feedthrough Filters Single Line Pi-Circuit (10-63A) 329 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 330 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 331 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 332 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 333 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 334 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 335 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 336 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 337 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 338 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 339 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 340 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 341 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 342 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 343 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 344 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 345 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 346 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 347 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 348 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 349 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 350 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 351 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 352 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 353 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 354 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 355 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 356 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 357 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 358 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 359 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 360 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 361 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 362 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 363 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 364 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 365 PREMO EMC Filters Housing mechanical dimensions HOUSING Mechanical dimensions 366