ALTECH DIN-Rail Power Supplies ENERGY SAVER Choose your product from a wide range of features and options, suitable for almost all applications. Slimline 6-19 • Small in size - narrow footprint • Powerful with generous power reserves • Simple usage • 10W to 100W Single Phase Low Profile 20-33 • Installs in seconds • Simple usage • Robust plastic case • 15W to 100W Industrial Metal Case Single Phase 34-43 • Single Phase Power Supply (75 to 480W) • Rugged metal case Industrial Metal Case Three Phase 44-59 • Three Phase Power Supply (240 to 960 W) • Rugged metal case High Efficiency Compact Housing Universal input voltage 60-71 • Rugged metal case • 150% peak load capacity Wide input voltage 72-81 • Rugged metal case • 120W to 480W Accessories 82-91 • Redundancy Buffer Module • UPS Module Frequently Asked Questions Selection Guide Index Terms and Conditions 92-94 95 94-97 98 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822 • Phone (908)806-9400 3 DIN Rail Power Supplies ENERGY SAVER • Din Rail mount, • Wide Power Range (10W-960W) • Wide Adjustment Range • Rugged for Industrial Use • High Efficiency • Lightweight and compact Design • 3 year warranty • Short circuit Protection • Overvoltage Protection • Overload Protection • Overtemperature Protection • Cooling by free air convection • Worldwide approvals • UL508 Listed and/or UL60950-1 recognized Rugged Metal Case Multiple output connector for easy wiring Adjustable DC output voltage DC (on) LED indicator Easy to understand layout panel UL508 Listed CE compliance Universal Input Narrow for maximized panel space 4 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Altech Power Supplies ... ...Easy to Use & Reliable! SPECIFICATIONS Input Output • Input Voltage • 90-264V AC for single phase • 100-550V AC for wide input • 340-550V AC for three phase • Input Frequency: 47-63 Hz • Input Current: 0.6 A to 8A • Inrush Current: cold start up to 60 A max • Power Factor: All units are EN61000-3-2 compliant General • Efficiency: 72-94% (see data sheets) • Isolation: 3000V AC Input to Output 1500V AC Input to Ground 500V AC Output to Ground Environmental Power supplies can run at 100% capacity inside the panel, there is no need for oversizing. See derating curves for more information. • Operating Temperature: -20 to +60°C (-4° to +140°F) • Operating Humidity: 90% RH, non-condensing • Storage Temperature: -20 °C to +85 °C (-4° to +185°F) • Vibration: 2G, 10 Hz to 500 kHz, 10 min/cycle for 60 minutes each axis • Output Voltage: 5V; 12V; 15V; 24V; 48V • Output Voltage Adjustment Range: ±10% • Initial Set Accuracy: ±2% max • Ripple & Noise: See data sheet • Over-voltage Protection: 115-135% • Overload Protection: 105-150%, constant current with auto recovery EMC & Safety • Emissions: EN55022/55011, Class B • EN61000-3-2, -3 • Voltage Flicker: EN61000-3-3 • ESD Immunity: EN61000-4-2, level 3 • Radiated Immunity: EN61000-4-3, 10 V/m • EFT/Burst: EN61000-4-4, level 3 • Surge: EN61000-4-5, level 3 • Conducted Immunity: EN61000-4-6, 10 V rms, • Safety Approvals: EN60950 UL508 UL60950 CE marked • Military Standard MIL-HDBK-217F Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 5 Slim line Single Phase Power Supply ALTECH’s slim type DIN rail switching power supply, PS-S Series designed for the fast growing demand of low wattage DIN rail applications. These 10W to 100W models are enclosed with fully isolated plastic case to prevent users from hazardous shock. The design complies with the slim trend that the precious space on the industrial rail can be saved effectively. Featuring up to 84% of efficiency, this series is cooled by only free air convection up to 70°C that significantly increase the reliability and lifetime of the power supply. Another important feature of PS-S Series is its low power consumption (<0.75W). This unique characteristic can significantly expand the application of PS-S series beyond just heavy industrial field, but can also be implied to datacom or IT applications that require green power to save the energy and to obey the anticipated government laws in the near future! Short circuit protection, overload protection, over voltage protection, and the DC OK signal for monitoring the status of power supply are standard functions for the PS-S Series. Typical applications includes factory automation, process control, electro-mechanical industry, datacom and IT. • Input voltage range: • AC inrush current (max): Cold start: • DC adjustment range: • Overload protection: • Over-voltage protection: • Setup, rise, time (max): • Withstand voltage: • Working temperature: • Safety standards: • EMC standards: • Military Standard 6 85-264V AC; 120-370V DC 20A at 115V AC,; 40A at 230V DC ±10% rated output voltage 105%-160% constant current limiting (auto- recovery) 115%-135% rated output voltage 500ms, 30ms/230V AC 1000ms, 30ms/115V AC, at full load I/P-O/P: 3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC -20 to +70°C (-4° to +158°F), refer to output derating curve UL508, EN60950-1 EN55022 class B EN61000-4-2,3,4,5,6,8,11 ENV50204; EN55024; EN61000-6-1; EN61204-3; Light Industry Level criteria A MIL-HDBK-217F For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. PS-S Series ENERGY SAVER Features: • Universal AC input/Full range • Protections: Short circuit / Overload / Overvoltage • Cooling by free air convection • DIN rail mountable • NEC class 2 / LPS compliant (12V,24V,48V only) • LED indicator for power on • DC OK relay contact • No load power consumption<0.75W • 100% full load burn-in test • 3 year warranty Multiple output connector for easy wiring on PS-S40, PS-S60 and PS-S100 models DC on LED signal 35mm DIN Rail Mounting Adjustable DC output voltage Easy to understand layout panel CE Compliance UL508 Listed Robust plastic housing Universal Input Slim Series - narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 7 10-100W Slimline POWER SUPPLIES ENERGY SAVER 10W Single Output Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-S1005 5V DC 2A ±5% 80 mVp-p 77% PS-S1012 12V DC 0.84A ±3% 120 mVp-p 81% PS-S1015 15V DC 0.67A ±3% 120 mVp-p 81% PS-S1024 24V DC 0.42A ±2% 150 mVp-p 84% NOTES 20W Single Output Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-S2005 5V DC 3A ±2% 80 mVp-p 76% PS-S2012 12V DC 1.67A ±1% 120 mVp-p 80% PS-S2015 15V DC 1.34A ±1% 120 mVp-p 81% PS-S2024 24V DC 1A ±1% 150 mVp-p 84% NOTES 40W Single Output Industrial DIN Rail Power Supply Cat. No. PS-S4005 Output V DC A Tol. % Ripple & Noise Efficiency 5V DC 6A ±2% 80 mVp-p 78% PS-S4012 12V DC 3.33A ±1% 120 mVp-p 86% PS-S4024 24V DC 1.7A ±1% 150 mVp-p 88% PS-S4048 48V DC 0.83A ±1% 200 mVp-p 88% NOTES 60W Single Output Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-S6005 5V DC 10A ±2% 80 mVp-p 78% PS-S6012 12V DC 5A ±1% 120 mVp-p 86% PS-S6024 24V DC 2.5A ±1% 150 mVp-p 88% PS-S6048 48V DC 1.25A ±1% 200 mVp-p 87% NOTES 100W Single Output Industrial DIN Rail Power Supply Cat. No. 8 Output V DC A Tol. % Ripple & Noise Efficiency PS-S10012 12V DC 7.5A ±1% 120 mVp-p 85% PS-S10024 24V DC 4A ±1% 150 mVp-p 86% PS-S10048 48V DC 2A ±1% 200 mVp-p 88% For more information please visit www.altechcorp.com NOTES SPECIFICATIONS xx01S-SP 22.5 100 90 PS-S10 Series 3 AC/L 2 AC/N 1 FG Pin No. Assignment 6 DC OK SIGNAL 5 DC OUTPUT -V 4 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 10 0 PS-S10xx 90 .5 22 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 4 DC OUTPUT +V DC OUTPUT -V 5 DC OK SIGNAL 6 Universal Input: 85-264V AC, 120-370V DC full range; 0.33A @ 110V AC; 0.21A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, single screw terminal Size (WxHxD): 22.5x90x100mm (0.89x3.54x3.94 inches) Packaging: 1/box; 0.37lbs / 0.17Kg xx02S-SP 22.5 100 90 PS-S20 Series 3 AC/L 2 AC/N 1 FG Pin No. Assignment 6 DC OK SIGNAL 5 DC OUTPUT -V 4 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 10 0 PS-S20xx 90 .5 22 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 4 DC OUTPUT +V DC OUTPUT -V 5 DC OK SIGNAL 6 Universal Input: 85-264V AC, 120-370V DC full range; 0.55A @ 110V AC; 0.35A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, single screw terminal Size (WxHxD): 22.5x90x100mm (0.89x3.54x3.94 inches) Packaging: 1/box; 0.42lbs / 0.19Kg 40 xx04S-SP 100 90 3 AC/L 2 AC/N 1 FG Pin No. Assignment 5/6 DC OK Relay Contact 3/4 DC OUTPUT -V 1/2 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) PS-S40 Series Pin No. 1 2 3 90 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1/2 DC OUTPUT -V 3/4 DC OK Relay Contact 5/6 PS-S40xx Universal Input: 85-264V AC, 120-370V DC full range; 1.1A @ 115V AC, 0.7A @ 370V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 40x90x100mm (1.57x3.54x3.94 inches) Packaging: 1/box; 0.66lbs / 0.3Kg 10 0 40 3 AC/L 2 AC/N 1 FG Pin No. Assignment 5/6 DC OK Relay Contact 3/4 DC OUTPUT -V 1/2 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) 40 xx06S-SP 100 90 Terminal Pin. No Assign. (TB1) PS-S60 Series Pin No. 1 2 3 90 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 1/2 DC OUTPUT +V DC OUTPUT -V 3/4 DC OK Relay Contact 5/6 PS-S60xx Universal Input: 85-264V AC, 120-370V DC full range; 1.8A @ 115V AC, 1A @ 370V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 40x90x100mm (1.57x3.54x3.94 inches) Packaging: 1/box; 0.73lbs / 0.33Kg 10 0 40 3 AC/L 2 AC/N 1 FG Pin No. Assignment 5/6 DC OK Relay Contact 3/4 DC OUTPUT -V 1/2 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) 55 xx001S-SP 100 90 Terminal Pin. No Assign. (TB1) PS-S100 Series Pin No. 1 2 3 PS-S100xx 90 10 0 55 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 1/2 DC OUTPUT +V DC OUTPUT -V 3/4 DC OK Relay Contact 5/6 Universal Input: 85-264V AC, 120-370V DC full range; 1.3A @ 115V AC, 0.8A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 55x90x100mm (2.17x3.54x3.94 inches) Packaging: 1/box; 0.93lbs / 0.42Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 9 PS-S10 Series Features: Specifications • • • • • • • • • • SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant Built in DC OK active signal LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty Cat. No. PS-S1005 PS-S1012 PS-S1015 PS-S1024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 2A 0~2A 10W 80mVp-p 12V 0.84A 0~0.84A 10W 120mVp-p 15V 0.67A 0~0.67A 10W 120mVp-p 24V 0.42A 0~0.42A 10W 150mVp-p VOLTAGE TOLERANCE ±5.0% Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor ±3.0% ±3.0% ±2.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±5.0% ±3.0% ±3.0% 500ms, 30ms/230VAC; 1000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 120ms/230VAC; 25ms/115VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85~264VAC; 120~370VDC 47~63Hz 77% 81% 0.33A/115VAC; 0.21A/230VAC COLD START: 35A/115VAC; 70A/230VAC <1mA/ 240VAC ±1.0% ±2.0% Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT INPUT PROTECTION PROTECTION OVERLOAD PROTECTION 81% 84% Above 105% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed OVERVOLTAGE PROTECTION 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V Protection type: Shut down overvoltage, re-power on to recover OVER TEMPERATURE PROTECTION ENVIRONMENT ENVIRONMENT SAFETY & EMC SAFETY & EMC DC OK AKTIV SIGNAL (max.) Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover 3.75~6V (50mA) 9~13.5V (40mA) 11.5~16.5V (40mA) 18~27V (20mA) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1compliant NEC class2 / LPS compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-1;EN61204-3; light industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS OTHERS that is still meets EMC directives. MTBF DIMENSION PACKING 584K hrs min. MIL-HDBK-217K (25˚C) 22.5x90x100mm (WxHxD) 0.17Kg; 72pcs / 13.2Kg / 0.91CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 10 Mechanical Specification 100 22.5 5 5 Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 +V -V DC OK Assignment FG AC/N AC/L 90 Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 4 DC OUTPUT -V 5 DC OK SIGNAL 6 N L 5 5 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT CONTROL O.L.P. O.V.P. Application of DC OK Signal Model 5V 12V 15V 24V R 5.1V R 200 1.5K 2K 3.9K R V- R 1K 2.4K 3K 4.7K Model 5V 12V 15V 24V Relay Model 5V 12V 15V 24V RL RL 120 700 700 1.2K V- V- Derating Curve Output Derating VS Input Voltage Ta=25 100 100 Others 80 90 80 5V 60 70 60 40 50 20 -20 40 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 11 PS-S20 Series Specifications ENERGY SAVER OUTPUT Features: • • • • • • • • • • Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant Built in DC OK active signal LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty Cat. No. PS-S2005 PS-S2012 PS-S2015 PS-S2024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 3A 0~3A 15W 80mVp-p 12V 1.67A 0~1.67A 20W 120mVp-p 15V 1.34A 0~1.34A 20W 120mVp-p 24V 1A 0~1A 24W 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 500ms, 30ms/230VAC; 1000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC; 20ms/115VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85~264VAC 120~370VDC 47~63Hz 76% 80% 0.55A/115VAC; 0.35A/230VAC COLD START: 20A/115VAC; 40A/230VAC ≤1mA/ 240VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. ±1.0% ±1.0% Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT PROTECTION OVERLOAD PROTECTION 81% 84% 105% ~ 160% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE PROTECTION 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V Protection type: Shut down overvoltage, re-power on to recover OVER TEMPERATURE PROTECTION ENVIRONMENT SAFETY & EMC DC OK AKTIV SIGNAL (max.) Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover 3.75~6V (50mA) 9~13.5V (40mA) 11.5~16.5V (40mA) 18~27V (20mA) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1approved NEC class2 / LPS compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-1;EN61204-3; light industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS MTBF DIMENSION PACKING 236.9K hrs min. MIL-HDBK-217K (25˚C) 22.5x90x100mm (WxHxD) 0.19Kg; 72pcs / 14.7Kg / 0.91CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 12 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 22.5 5 5 +V -V DC OK Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L + +V ADJ 90 Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. Assignment 4 DC OUTPUT +V DC OUTPUT -V 5 DC OK SIGNAL 6 N L 5 5 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V -V DETECTION CIRCUIT O.L.P. CONTROL O.V.P. Application of DC OK Signal Model 5V 12V 15V 24V R 5.1V R 200 1.5K 2K 3.9K R V- R 1K 2.4K 3K 4.7K Model 5V 12V 15V 24V Relay Model 5V 12V 15V 24V RL RL 120 700 700 1.2K V- V- Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 60 60 40 50 20 -20 40 0 10 20 30 40 50 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 13 PS-S40 Series Features: Specifications ENERGY SAVER OUTPUT • • • • • • • • • Universal AC input/full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant (12V,24V,48V only) LED indicator for power on DC OK relay contact No load power consumption < 0.75W 100% full load burn-in test 3 year warranty Cat. No. PS-S4005 PS-S4012 PS-S4024 PS-S4048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 6A 0~6A 30W 80mVp-p 12V 3.33A 0~3.33A 40W 120mVp-p 24V 1.7A 0~1.7A 40.8W 150mVp-p 48V 0.83A 0~0.83A 39.8W 200mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 5 ~ 6V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC; 20ms/115VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85~264VAC 120~370VDC 47~63Hz 78% 86% 1.1A/115VAC; 0.7A/230VAC COLD START: 30A/115VAC; 60A/230VAC ≤1mA/ 240VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 12 ~ 15V ±1.0% 24 ~ 30V ±1.0% 48 ~ 56V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. ±1.0% ±1.0% Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT PROTECTION OVERLOAD PROTECTION 88% 88% 105% ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE PROTECTION 6.25~7.25V 15.6~18V 31.2~36V 57.6~64.8V Protection type: Shut down overvoltage, re-power on to recover OVER TEMPERATURE PROTECTION ENVIRONMENT SAFETY & EMC DC OK AKTIV SIGNAL (max.) Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/ 1A resistive WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 UL60950-1 EN60950-1approved NEC class2 / LPS compliant (12V, 24V, 48V only) I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC (25°C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204 ; EN61000-6-2; EN61204-3; light industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS MTBF DIMENSION PACKING 301.7K hrs min. MIL-HDBK-217K (25˚C) 40x90x100mm (WxHxD) 0.3Kg; 42pcs / 13.6 Kg / 0.82CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 14 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 40 100 5 5 5 5 5 +V +V-V -V Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L + +V ADJ 90 Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V DC OUTPUT -V 3,4 DC OK RELAY CONTACT 5,6 N L 7.5 7.5 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. DETECTION CIRCUIT O.L.P. CONTROL O.V.P. DC OK Relay Contact age. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 60 60 40 50 20 -20 40 0 10 20 30 45 55 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 15 PS-S60 Series Features: Specifications • • • • • • • • • ENERGY SAVER OUTPUT Universal AC input/full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant (24V,48V only) LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty Cat. No. PS-S6005 PS-S6012 PS-S6024 PS-S6048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER NOISE (max) 5V 10A 0 ~ 10A 50W 80mVp-p 12V 5A 0 ~ 5A 60W 120mVp-p 24V 2.5A 0 ~ 2.5A 60W 150mVp-p 48V 1.25A 0 ~ 1.25A 60WRIPPLE & 200mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 5 ~ 6V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±1.5% ±1.0% ±1.0% 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC / 20ms/115VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85 ~ 264VAC 120 ~ 370VDC 47~63Hz 78% 86% 1.8A/115VAC; 1A/230VAC COLD START: 60A/230VAC ≤1mA/ 240VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 12 ~ 15V ±1.0% 24 ~ 30V ±1.0% 48 ~ 56V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. ±1.0% ±1.0% Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT PROTECTION OVERLOAD PROTECTION 88% 87% 105% ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE PROTECTION 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type: Shut down overvoltage, re-power on to recover OVER TEMPERATURE PROTECTION ENVIRONMENT SAFETY & EMC DC OK AKTIV SIGNAL (max.) Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/1A resistive WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 UL60950-1 EN60950-1approved NEC class2 / LPS compliant (24V, 48V only) I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC (25°C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; light industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS MTBF DIMENSION PACKING 299.2K hrs min. MIL-HDBK-217K (25˚C) 40x90x100mm (WxHxD) 0.33Kg; 42pcs / 14.8Kg / 0.82CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 16 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 40 100 5 5 5 5 5 +V +V-V -V Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L Pin No. 1 2 3 + 90 Terminal Pin. No Assign. (TB2) +V ADJ Pin No. Assignment 1,2 DC OUTPUT +V DC OUTPUT -V 3,4 DC OK RELAY CONTACT 5,6 N L 7.5 7.5 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. DETECTION CIRCUIT CONTROL O.L.P. O.V.P. DC OK Relay Contact age. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 12V,24V,48V 90 80 80 70 60 50 5V 60 40 50 20 -20 40 0 10 20 30 45 55 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 17 PS-S100 Series Specifications SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT Features: • Universal AC input / full range • Protections: Short Circuit / Overload / Overvoltage / Over temperature • ZCS/ZVS technology to reduce power dissipation • Cooling by free air convection • DIN rail mountable • DC OK relay contact • No load power consumption < 1W • LED indicator for power on • 100% full load burn-in test • 3 year warranty Cat. No. PS-S10012 PS-S10024 PS-S10048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 7.5A 0 ~ 7.5A 90W 120mVp-p 24V 4A 0 ~ 4A 96W 150mVp-p 48V 2A 0 ~ 2A 96W 200mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 15V ±1.0% 24 ~ 30V ±1.0% 48 ~ 56V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION LOAD REGULATION SETUP, RISE TIME ±1.0% ±1.0% ±1.0% ±1.0% 3000ms, 50ms/230VAC; 3000ms, 50ms/115VAC at full load ±1.0% ±1.0% Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. INPUT INPUT HOLD UP TIME (Typ.) VOLTAGE RANGE 50ms/230VAC; 20ms/115VAC at full load 85 ~ 264VAC 120 ~ 370VDC Deating maybe needed under low input voltages, please check the derating curve for more detail PROTECTION PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 47~63Hz PF ≥ 0.95/230VAC; PF ≥ 0.98/115VAC at full load 85% 86% 1.3A/115VAC; 0.8A/230VAC COLD START: 30A/115VAC; 60A/230VAC ≤1mA/ 240VAC 88% 105% ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 90˚C ± 10˚C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover SHORT CUIRCUIT PROTECTION ENVIRONMENT ENVIRONMENT SAFETY & EMC SAFETY & EMC DC OK AKTIV SIGNAL (max.) Power supply shut down at 70˚C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/1A resistive WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1compliant I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC/25˚C/70% RH Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; light industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS OTHERS MTBF DIMENSION PACKING 346K hrs min. MIL-HDBK-217K (25˚C) 55x90x100mm (WxHxD) 0.42Kg; 30pcs / 13.6Kg / 0.82CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 18 Mechanical Specification Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V DC OUTPUT -V 3,4 DC OK RELAY CONTACT 5,6 Block Diagram DC OK Relay Contact Derating Curve Output Derating VS Input Voltage Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 19 Low Profile Single Phase Power Supply (Class II) The Low Profile Single Phase Power Supplies are 15W to 100W single output Class II DIN rail switching power supplies. They are designed for the fast growing demand of the DIN rail application with limited enclosure height. With Class II of protection level, low profile series provide users a safer operating environment since the whole plastic case is free from hazardous leakage current. Featuring up to 89% of high efficiency, this series can be cooled by only free air convection that significantly increase the reliability and lifetime of the power supply. Complying with the safety of the UL508 and EMC requirements of EN50178 which is mainly for power distribution aspects, the low profile switching power supplies are suitable to be installed in a power distribution box or a control cabinet and the major application fields are building automation and household appliance control. • Input voltage range: • AC inrush current: • DC adjustment range: • Overload protection: • Over-voltage protection: • Setup, rise, hold up time: • Withstand voltage: • Working temperature: • Safety standards: • EMC standards: • Military Standard: 20 85-264V AC; 120-370V DC Cold start: 15A at 115V AC, 30A at 230V DC (PS-30xx) ±10% rated output voltage 105%-160% constant current limiting, auto-recovery 115%-135% rated output voltage 100ms, 30ms, 100ms at full loadand 230V AC (PS-30xx) I/P-O/P:3KV AC, I/P-FG:1.5KV AC -20 to +50°C (-4° to +122°F) at 100% and +60°C (+140°F) at 80% load UL60950-1, UL508 EN55022 class B EN61000-4-2,3,4,5,6,8,11 ENV50204 EN61204-3 MIL-HDBK For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. PS Series - Low Profile ENERGY SAVER Features: • Universal AC input/Full range • Protections: Short circuit / Overload / Overvoltage • Cooling by free air convection • DIN rail mountable • Isolation class II • LED indicator for power on • 100% full load burn-in test • 3 year warranty Output connector for easy wiring DC on LED signal Adjustable DC output voltage 35mm DIN Rail Mounting Easy to understand layout panel UL508 Listed Robust plastic housing Universal Input Compact Series - narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 21 15-100W Low Profile POWER SUPPLIES 15W Single Output Class II DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-1505 5V DC 2.4A ±2% 80 mVp-p 77% PS-1512 12V DC 1.25A ±1% 120 mVp-p 84% PS-1515 15V DC 1A ±1% 120 mVp-p 83.5% PS-1524 24V DC 0.63A ±1% 150 mVp-p 85% ENERGY SAVER NOTES 30W Single Output Class II DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-3005 5V DC 3A ±2% 80 mVp-p 74% PS-3012 12V DC 2A ±1% 120 mVp-p 81% PS-3015 15V DC 2A ±1% 120 mVp-p 82% PS-3024 24V DC 1.5A ±1% 150 mVp-p 83% NOTES 45W Single Output Class II DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-4505 5V DC 5A ±2% 100 mVp-p 72% PS-4512 12V DC 3.5A ±1% 200 mVp-p 77% PS-4515 15V DC 2.8A ±1% 240 mVp-p 77% PS-4524 24V DC 2A ±1% 480 mVp-p 80% NOTES 60W Single Output Class II DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-6005 5V DC 6.5A ±2% 80 mVp-p 76% PS-6012 12V DC 4.5A ±1% 120 mVp-p 82% PS-6015 15V DC 4.0A ±1% 120 mVp-p 83% PS-6024 24V DC 2.5A ±1% 150 mVp-p 84% 100W Single Output Class II DIN Rail Power Supply Cat. No. 22 Output V DC A Tol. % Ripple & Noise Efficiency PS-10012 12V DC 7.5A ±2% 120 mVp-p 87% PS-10015 15V DC 6.5A ±1% 120 mVp-p 87% PS-10024 24V DC 4.2A ±1% 150 mVp-p 89% NOTES ENERGY SAVER NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS PS-15 Series Terminal Pin. No Assignment Pin No. Assignment Pin No. Assignment AC/L -V 1 3 AC/N +V 2 4 93 Universal Input: 85-264V AC, 120-370V DC full range; 0.88A @ 115V AC; 0.48A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, single screw terminal Size (WxHxD): 25x93x56mm (0.98x3.66x2.20 inches) Packaging: 1/box; 0.22lbs / 0.1Kg 56 25 Terminal Pin. No Assignment PS-30 Series Pin No. 1 2 3,4 93 56 78 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 Universal Input: 85-264V AC, 120-370V DC full range; 0.88A @ 115V AC; 0.48A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 78x93x56mm (3.07x3.66x2.20 inches) Packaging: 1/box; 0.60lbs / 0.27Kg Terminal Pin. No Assignment PS-45 Series Pin Assignment Pin AC/L 1 6,7 AC/N 2 8 9 3 FG 4,5 DC OUTPUT-V 93 67 78 Assignment DC OUTPUT+V LED +V ADJ. Universal Input: 85-264V AC, 120-370V DC full range; 1.5A @ 115V AC, 0.75A @ 230V AC Connection: Input - 3 poles, Output – 2 poles, double screw terminal Size (WxHxD): 78x93x67mm (3.07x3.66x2.64 inches) Packaging: 1/box; 0.68lbs / 0.31Kg Terminal Pin. No Assignment PS-60 Series Pin No. 1 2 3,4 93 56 78 PS-100 Series Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 Universal Input: 88-264V AC, 124-370V DC full range; 1.2A @ 115V AC, 0.8A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 78x93x56mm (3.07x3.66x2.20 inches) Packaging: 1/box; 0.66lbs / 0.30Kg Terminal Pin. No Assignment Pin No. 1 2 3,4 93 0 56 10 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 Universal Input: 88-264V AC, 124-370V DC full range; 3A @ 115V AC, 1.6A @ 230V AC Connection: Input - 2 poles, Output – 2 poles, double screw terminal Size (WxHxD): 100x93x56mm (3.94x3.66x2.20 inches) Packaging: 1/box; 0.77lbs / 0.35Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 23 12 PS-15 Series Features: Specifications • • • • • • • • • ENERGY SAVER OUTPUT Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on No load power consumption<0.5W 100% full load burn-in test 3 year warranty Cat. No. PS-1505 PS-1512 PS-1515 PS-1524 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 2.4A 0 ~ 2.4A 12W 80mVp-p 12V 1.25A 0 ~ 1.25A 15W 120mVp-p 15V 1A 0 ~ 1A 15W 120mVp-p 24V 0.63A 0 ~ 0.63A 15.2W 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load 70ms / 230VAC 16ms / 115VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 77% 84% 0.88A / 115VAC 0.48A / 230VAC COLD START 35A / 115VAC 65A / 230VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION OVERLOAD 83.50% ±1.0% ±1.0% 85% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed (Hiccup mode) Constant current operation region is within 60 ~ 100% rated output voltage. OVERVOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, clamping by zener diode ENVIRONMENT SAFETY & EMC WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms/500VDC (25˚C; 70% RH) Compliance to EN55011 EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. OTHERS The final equipment must be re-confirmed that is still meets EMC directives. MTBF DIMENSION PACKING 1172.3K hrs min. MIL-HDBK-217K (25˚C) 25x93x56mm (WxHxD) 0.1Kg; 140pcs / 15Kg / 0.92CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 24 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 56 25 47 26.7 5 -V +V LE D Terminal Pin. No Assignment 67.2 93 44.2 Vadj. Pin No. Assignment Pin No. Assignment AC/L -V 1 3 AC/N +V 2 4 4 N L 5 Block Diagram RE CTIFIERS & FILTE R EMI FILTE R I/P RE CTIFIE RS & FILTE R POWE R SWITCHING +V -V DE TE CTION CIRCUIT O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 LOAD (%) LOAD (%) 80 60 40 80 70 60 50 20 -20 40 0 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 25 PS-30 Series Features: Specifications OUTPUT • • • • • • • • Universal AC input/ full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty Cat. No. PS-3005 PS-3012 PS-3015 PS-3024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 3A 0 ~ 3A 15W 80mVp-p 12V 2A 0 ~ 2A 24W 120mVp-p 15V 2A 0 ~ 2A 30W 120mVp-p 24V 1.5A 0 ~ 1.5A 36W 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% 100ms, 30ms / 230VAC 100ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 74% 81% 0.88A / 115VAC 0.48A / 230VAC COLD START 15A / 115VAC; 30A / 230VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION OVERLOAD ±1.0% ±1.0% ±1.0% ±1.0% 100ms, 30ms / 115VAC at full load 21ms / 115VAC at full load 82% ±1.0% ±1.0% 83% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed OVERVOLTAGE ENVIRONMENT SAFETY & EMC 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, clamping by zener diode WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms / 500VDC Compliance to EN55011 EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS that is still meets EMC directives. MTBF DIMENSION PACKING 441.5K hrs min. MIL-HDBK-217K (25˚C) 78x93x56mm (WxHxD) 0.27Kg; 48pcs / 14Kg / 1.02CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 26 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 56 47 78 5 1 2 Terminal Pin. No Assignment 27.4 45 68 7 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 93 Pin No. 1 2 3,4 5 5 5 12.2 3 4 5 6 37.75 3 8 Block Diagram RE CTIFIE RS & FILTE R E MI FILTE R I/P POWE R SWITCHING R E CTIFIE R S & FILTE R +V -V DE TE CTION CIRCUIT O.L.P. CONTR OL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 LOAD (%) LOAD (%) 80 60 40 70 60 50 20 -20 40 0 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 27 PS-45 Series Features: Specifications OUTPUT • Universal AC input / full range • Protections: Short Circuit / Overload / Over Voltage/ Overtemperature • Cooling by free air convection • DIN rail mountable • UL508 approved • LED indicator for power on • Fix switching frequency at 100kHz • 100% full load burn-in test • 3 year warranty Cat. No. PS-4505 PS-4512 PS-4515 PS-4524 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 5A 0 ~ 5A 25W 100mVp-p 12V 3.5A 0 ~ 3.5A 42W 200mVp-p 15V 2.8A 0 ~ 2.8A 42W 240mVp-p 24V 2A 0 ~ 2A 48W 480mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% ±1.0% ±1.0% 800ms, 60ms / 230VAC at full load 60ms / 230VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 72% 77% 1.5A / 115VAC 0.75A / 230VAC COLD START 28A / 115VAC; 56A / 230VAC ≤1mA / 240VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION OVERLOAD ±1.0% ±1.0% ±1.0% ±1.0% 77% 80% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed OVERVOLTAGE 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, clamping by zener diode OVERTEMPERATURE ENVIRONMENT SAFETY & EMC Tj 135˚C typically (U1) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover WORKING TEMPERATURE WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +50˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25°C; 70% RH) Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. OTHERS The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 364.6K hrs min. MIL-HDBK-217K (25˚C) 93x78x67mm (LxWxH) 0.31Kg; 48pcs / 16.1Kg / 1.3CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 28 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 67 78 29 9 7 8 5 6 3 4 1 2 7.5 8.5 Terminal Pin. No Assignment 93 Assignment DC OUTPUT+V LED +V ADJ. 77 Pin Assignment Pin 1 AC/L 6,7 2 AC/N 8 3 FG 9 4,5 DC OUTPUT-V Block Diagram RE CTIFIE RS & FILTE R E MI FILTE R I/P POWE R SWITCHING RE CTIFIE RS & FILTE R PWM CONTR OL DE TE CTION CIRCUIT FG Derating Curve +V -V Static Characteristic (24V) 100 LOAD (%) LOAD (%) 80 60 40 350 28 300 24 250 20 200 16 150 12 100 8 50 20 -10 0 10 20 30 40 50 60 (VERTICAL) AMBIENT TEMPERATURE (°C) 70 80 OUTPUT RIPPLE (mVp-p) Ta=25 32 100 120 140 160 180 200 220 240 260 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 29 PS-60 Series Features: Specifications OUTPUT • • • • • • • • Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty Cat. No. PS-6005 PS-6012 PS-6015 PS-6024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 6.5A 0 ~ 6.5A 32.5W 80mVp-p 12V 4.5A 0 ~ 4.5A 54W 120mVp-p 15V 4A 0 ~ 4A 60W 120mVp-p 24V 2.5A 0 ~ 2.5A 60W 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% 100ms, 30ms / 230VAC 100ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) 85 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 76% 82% 1.2A / 115VAC 0.8A / 230VAC COLD START 18A / 115VAC; 36A / 230VAC Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 11.1 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION OVERLOAD ±1.0% ±1.0% ±1.0% ±1.0% 200ms, 30ms / 115VAC at full load 23ms / 115VAC at full load 83% ±1.0% ±1.0% 84% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed OVERVOLTAGE ENVIRONMENT SAFETY & EMC 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms/500VDC (25°C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; EN61204-3; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS MTBF DIMENSION PACKING 216.2K hrs min. MIL-HDBK-217K (25˚C) 78x93x56mm (WxHxD) 0.3Kg; 48pcs / 15.4Kg / 1.02CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature 30 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 56 78 47 37.75 5 5 5 12.2 Terminal Pin. No Assignment 45 68 7 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 93 Pin No. 1 2 3,4 27.4 3 4 5 6 1 2 5 3 8 Block Diagram RE CTIFIE RS & FILTE R E MI FILTE R I/P POWE R SWITCHING O.L.P. R E CTIFIE R S & FILTE R +V -V DE TE CTION CIRCUIT PWM CONTR OL O.V.P. Output Derating VS Input Voltage Derating Curve Ta=25 100 100 90 LOAD (%) LOAD (%) 80 60 40 80 70 60 50 20 -20 40 0 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 31 PS-100 Series Features: • Universal AC input / full range • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • DIN rail mountable • Isolation class II • LED indicator for power on • No load power consumption<1W • 100% full load burn-in test • 3 year warranty Specifications SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT Cat. No. PS-10012 PS-10015 PS-10024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 7.5A 0 ~ 7.5A 90W 120mVp-p 15V 6.5A 0 ~ 6.5A 97.5W 120mVp-p 24V 4.2A 0 ~ 4.2A 100.8W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 15V ±2.0% 15 ~ 18V ±1.0% 24 ~ 29V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT INPUT PROTECTION PROTECTION LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% 2700ms, 80ms / 230VAC 50ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) 88 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 87% 87% 3A / 115VAC 1.6A / 230VAC COLD START 30A / 115VAC; 45A / 230VAC OVERLOAD ±1.0% ±1.0% 2700ms, 80ms / 115VAC at full load 18ms / 115VAC at full load ±1.0% ±1.0% 89% 105 ~ 135% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed Under short circuit or overload ≥ 150% conditions, output voltage may shut down for 5 sec. and then go into constant current protection mode OVERVOLTAGE 16 ~ 20V 19 ~ 23V 30 ~ 35V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 90˚C ± 15˚C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 ENVIRONMENT ENVIRONMENT SAFETY & EMC SAFETY & EMC SAFETY STANDARDS UL60950-1 EN60950-1compliant Design refer to EN50178 WITHSTAND VOLTAGE I/P-O/P: 3KVAC ISOLATION RESISTANCE I/P-O/P: 100M Ohms/500VDC (25°C; 70% RH) EMI CONDUCTION & RADIATION Compliance to EN61204-3; EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Harmonic current test @ 90% load EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS OTHERS Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; EN61204-3; heavy industry level; criteria A MTBF DIMENSION PACKING NOTE 486K hrs min. MIL-HDBK-217K (25˚C) 100x93x56mm (WxHxD) 0.35Kg; 36pcs / 13.6Kg / 0.89CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 32 Mechanical Specification 56 100 5 47 3 4 5 6 1 2 Terminal Pin. No Assignment 7 45 93 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8 68 Pin No. 1 2 3,4 27.4 5 5 5 7.5 64.75 3 8 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 LOAD (%) LOAD (%) 80 60 40 80 70 60 50 20 -20 40 0 10 20 30 40 45 50 60 AMBIENT TEMPERATURE (°C) 70 (VERTICAL) 88 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 33 Industrial Metal Case Single Phase and Three Phase Power Supply The Altech Industrial metal case power supplies have been optimized for use in practically any DC power applications, with a wide range of AC/DC inputs and an extended temperature range of -20° C up to +70° C. These metal case power supplies feature a small housing design and high power reserve. Excellent electrical specifications and high immunity against fluctuations in input voltage make these metal case modules the best choice to industrial automation. Altech’s metal case power supplies are available in six single-phase and four three-phase models with 12VDC (75W and 120W), 24 VDC and 48VDC output voltages, and up to 40A output currents. This voltage range enables the Industrial metal case supplies to be used in virtually any single-phase or three-phase application. The Industrial metal case power supply series offers users easy wiring with screw terminal blocks and snap-on DIN-rail mounting. Designed for use in numerous applications around the world, this power supplies are UL and CSA approved, CE marked and ROHS compliant. They feature a rugged metal housing, vibration- and shock-proof construction and provide a cost-effective power delivery solution for basic functionality requirements. Single Phase Power Supply: • Input voltage range: • AC inrush current: Cold start: • Overload voltage protection: • Over-voltage protection: • Setup, rise, hold up time: • Working temperature: 85-264V AC / 120-370V DC 20A at 115V AC, 40A at 230V AC 105%-160% constant current limiting auto-recovery 115%-135% rated output voltage 500ms; 70ms; 30ms at full load and 230V AC -20 to +50°C (-4° to +122°F) at 100% +60°C (+140°F) at 80% load Three Phase Power Supply: • Three phase input • Input voltage range: • AC inrush current: • Overload voltage protection: • Over-voltage protection: • Setup, rise, hold up time: • Working temperature: • EMC standards: 340-550V AC / 480-760V DC Cold start: 50A 105%-150% constant current limiting auto-recovery 115%-135% rated output voltage 1200ms, 40ms, 20ms @ 400V AC 800ms, 40ms, 40ms @ 500V AC full load -20 to +70°C (-4 to +158°F) at 100% EN61000-6-2 (EN50082-2) Heavy Industrial Level; criteria A Single Phase 75-240W.............................................................................pages 36-45 480W and 480W Switch Select..........................................pages 46-51 Three Phase 240-960W...........................................................................pages 52-59 34 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. PS Series - Metal Case Features: • Universal AC input / Full range • Single phase or Three phase • Built in active PFC function • Protections: Short circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • DIN rail mountable • UL 508 (industrial control equipment) approved • LED indicator for power on • 100% full load burn-in test • 3 year warranty DC on LED signal Universal Input 35mm DIN Rail mounting Easy to understand layout panel UL508 Compliance CE Compliance Rugged metal housing Multiple output connector for easy wiring Narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 35 75-240W Single Phase POWER SUPPLIES 75W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-7512 12V DC 6.3A ±2% 100 mVp-p 76% PS-7524 24V DC 3.2A ±1% 150 mVp-p 80% PS-7548 48V DC 1.6A ±1% 240 mVp-p 81% NOTES 120W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-12012 12V DC 10A ±2% 80 mVp-p 80% PS-12024 24V DC 5A ±1% 80 mVp-p 84% 2.5A ±1% 100 mVp-p 85% PS-12048 48V DC NOTES 110/220V SWITCH SELECT 120W High Input Single Output DIN Rail Power Supply Cat. No. PSH-12024 PSH-12048 Output V DC A 24V DC 48V DC Tol. % Ripple & Noise Efficiency 5A ±1% 80 mVp-p 85% 2.5A ±1% 80 mVp-p 86% NOTES HIGH INPUT 240W Single Output DIN Rail Power Supply with PFC Function Cat. No. 36 Output V DC A Tol. % Ripple & Noise Efficiency PSP-24024 24V DC 10A ±1% 80 mVp-p 84% PSP-24048 48V DC 5A ±1% 150 mVp-p 85% NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS PS-75 Series Terminal Pin. No Assign. (TB1) 12 Pin No. 1 2 3 5.2 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1,2 DC OUTPUT -V 3,4 Universal Input: 10 0 .5 55 PS-120 Series 85-264V AC, 120-370V DC full range, 1.6A @ 115V AC, 0.96A @ 230V AC Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 55.5x125x100mm (2.20x4.95x3.95 inches) Packaging: 1/box; 1.35lbs / 0.60Kg Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 (Switch Select) 12 5.2 10 PSH-120 High Input Series 12 0 .5 65 Switch select Input: 88-132V AC / 176-264 V AC, 248-370V DC range, 2.6A @ 115V AC, 1.6A @ 230V AC Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 65.5x125x100mm (2.56x4.95x3.95 inches) Packaging: 1/box; 1.75lbs / 0.79Kg Terminal Pin. No Assign. (TB1) Assignment 1 FG 2 AC/N(L2) 3 AC/L(L1) 5.2 Terminal Pin. No Assign. (TB2) Assignment 1,2 3,4 Universal Input: 10 0 .5 65 PSP-240 Series 340-550V AC, 480-780V DC range, 0.65A @ 400V AC, 0.6A @ 500V AC Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 65.5x125x100mm (2.56x4.95x3.95 inches) Packaging: 1/box; 1.65lbs / 0.75Kg Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 25 Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1,2 DC OUTPUT -V 3,4 Assignment FG AC/N AC/L Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1,2 DC OUTPUT -V 3,4 .2 Universal Input: 10 0 5.5 12 85-264V AC, 120-370V DC full range, 2.8A @ 115V AC, 1.4A @ 230V AC Built in active Power Factor Correction function. PF>0.95 Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 125x125x100mm (4.95x4.95x3.95 inches) Packaging: 1/box; 2.7lbs / 1.2Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 37 PS-75 Series Features: Specifications OUTPUT • Univers al AC input / full range • Protections: Short Circuit / Over load / Overvoltage / Over temperature • Cooling by free air convection • DIN rail mountable • UL508 (industrial control equipment) approved • LED indicator for power on • 100% full load burn-in test • Fix switching frequency at 50KHz • 3 year warranty Cat. No. PS-7512 PS-7524 PS-7548 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 6.3A 0 ~ 6.3A 76W 100mVp-p 24V 3.2A 0 ~ 3.2A 76.8W 150mVp-p 48V 1.6A 0 ~ 1.6A 76.8W 240mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 14V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±0.5% ±1.0% 1000ms, 60ms / 230VAC 60ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 76% 1.6 A / 115VAC 0.96A / 230VAC COLD START 20A / 115VAC ≤ 1mA / 240VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 15 ~ 16.5V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 24 ~ 28V ±1.0% 48 ~ 53V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION ±0.5% ±1.0% 1800ms, 60ms / 115VAC at full load 12ms / 115VAC at full load 80% ±0.5% ±1.0% 81% 40A / 230VAC Protection type: Constant current limiting, recovers automatically after fault condition is removed 29 ~ 34V 58 ~ 65V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE ENVIRONMENT SAFETY & EMC Protection type: Shut down overvoltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2) heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY OTHERS 85˚C ± 5˚C (TSW1) detect on heat sink of power transistor The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 123.1K hrs min. MIL-HDBK-217K (25˚C) 55.5x125.2x100mm (WxHxD) 0.6Kg; 20pcs / 13Kg / 1.29CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 38 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 55.5 1 2 3 125.2 TB1 TB2 4 3 2 1 LE D 100 Terminal Pin. No Assignment (TB2) Terminal Pin. No Assignment (TB1) Pin No. 1 2 3 Pin No. 1,2 3,4 Assignment FG AC/N AC/L Assignment DC OUTPUT +V DC OUTPUT -V Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. O.T.P. PWM CONTROL O.V.P. Output Derating VS Input Voltage Derating Curve 100 100 24V,48V 90 12V LOAD (%) LOAD (%) 80 60 40 80 70 60 50 20 -10 40 0 10 20 30 45 50 60 (VERTICAL) AMBIENT TEMPERATURE (°C) 85 90 105 125 145 165 185 205 225 245 265 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 39 PS-120 Series Features: Specifications • Universal AC input / full range • Protections: Short Circuit / Over load / Overvoltage/Over temperature • Cooling by free air convection • DIN rail mountable TS-35/ 7.5 or 1 5 • UL 508 (industrial control equipment) approved • LED indicator for power on • 100% full load burn-in test • Fix switching frequency at 50KHz • 3 year warranty 110/220V SWITCH SELECT OUTPUT Cat. No. PS-12012 PS-12024 PS-12048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 10A 0 ~ 10A 120W 80mVp-p 24V 5A 0 ~ 5A 120W 80mVp-p 48V 2.5A 0 ~ 2.5A 120W 100mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 14V ±2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±0.5% ±1.0% 500ms, 70ms / 230VAC 36ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 88 ~ 132VAC / 176 ~ 264VAC by switch 47 ~ 63Hz 80% 84% 2.6 A / 115VAC 1.6A / 230VAC COLD START 20A / 115VAC 40A / 230VAC ≤ 3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 15 ~ 16.5V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 24 ~ 28V ±1.0% 48 ~ 53V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION ±0.5% ±1.0% 500ms, 70ms / 115VAC at full load 32ms / 115VAC at full load ±0.5% ±1.0% 248 ~ 370VDC 85% Protection type: Constant current limiting, recovers automatically after fault condition is removed 29 ~ 33V 58 ~ 65V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 90˚C ± 5˚C (TSW1) 90˚C ± 5˚C (TSW1) Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT SAFETY & EMC 85˚C ± 5˚C (TSW1) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 UL60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 136.8K hrs min. MIL-HDBK-217K (25˚C) 65.5x125.2x100mm (WxHxD) 0.79Kg; 20pcs / 16.5Kg / 1.29CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 40 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification LE D TB2 1 2 3 4 100 115VAC 1 2 3 TB1 125.2 230VAC 65.5 Terminal Pin. No Assignment (TB2) Terminal Pin. No Assignment (TB1) Pin No. 1 2 3 Pin No. 1,2 3,4 Assignment FG AC/N AC/L Block Diagram Assignment DC OUTPUT +V DC OUTPUT -V 230 115 RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. O.T.P. Derating Curve PWM CONTROL O.V.P. Static Characterisitcs (24V) 48V 100 350 28 300 24 250 20 200 16 150 12 100 60 LOAD (%) LOAD (%) 80 12V,24V 40 20 8 -10 0 10 20 30 45 50 AMBIENT TEMPERATURE (°C) 60 (VERTICAL) 80 80 160 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 OUTPUT RIPPLE (mVp-p) Ta=25 32 130 260 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 41 PSH-120 High Input Series Specifications Features: • Universal AC input / full range • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • Fixed switching frequency at 70KHz • 3 year warranty HIGH INPUT OUTPUT Cat. No. PSH-12024 PSH-12048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 5A 0 ~ 5A 120W 80mVp-p 48V 2.5A 0 ~ 2.5A 120W 80mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME ±0.5% ±0.5% 1700ms, 120ms, 16ms / 400VAC VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (max.) LEAKAGE CURRENT 340 ~ 550VAC 480 ~ 780VDC 47 ~ 63Hz 85% 0.65A / 400VAC 0.6A / 500VAC COLD START 50A ≤ 3.5 mA / 530VAC OVERLOAD 105 ~ 160% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION ±0.5% ±0.5% 1000ms, 120ms, 30ms / 500VAC at full load 86% Protection type: Constant current limiting, recovers automatically after fault condition is removed 59 ~ 66V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 85˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT SAFETY & EMC WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 approved IEC60950-1 CB approved by SIQ I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55011 (CISPR11); EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 178.7K hrs min. MIL-HDBK-217K (25˚C) 65.5x125.2x100mm (WxHxD) 0.75Kg; 20pcs / 16Kg / 1.29CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 42 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification TB1 1 2 3 125.2 LED TB2 1 2 3 4 100 65.5 1 2 3 Assignment Assignment FG AC/L2 AC/L1 1,2 3,4 Block Diagram EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V DETECTION CIRCUIT FG CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL O.V.P. Derating Curve 100 80 60 50 40 20 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 43 PSP-240 Series Features: Specifications OUTPUT • Universal AC input / full range • Built in active PFC function • Protections: Short Circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • DIN rail mountable • UL 508(industrial control equipment)approved • LED indicator for power on • 100% full load burn-in test • Fixed switching frequency at 100KHz • 3 year warranty Cat. No. PSP-24024 PSP-24048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 10A 0 ~ 10A 240W 80mVp-p 48V 5A 0 ~ 5A 240W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% 48 ~ 53V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) INPUT VOLTAGE RANGE ±0.5% ±1.0% 800ms, 40ms / 230VAC 24ms / 230VAC 85 ~ 264VAC ±0.5% ±1.0% 800ms, 40ms / 115VAC at full load 24ms / 115VAC at full load 120 ~ 370VDC Derating may be needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT PROTECTION OVERLOAD 47 ~ 63Hz 0.96 / 230VAC 0.99 / 115VAC at full load 84% 2.8A / 115VAC; 1.4A / 230VAC COLD START 27A / 115VAC 45A / 230VAC ≤ 3.5mA / 240VAC 85% 105 ~ 150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE 30 ~ 36V 54 ~ 60V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 100˚C ± 5˚C (TSW: detect on heat sink of power transistor) Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); heavy industry level; criteria A SAFETY & EMC WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 289.9K hrs min. MIL-HDBK-217K (25˚C) 125.5x125.2x100mm (WxHxD) 1.2Kg; 12pcs / 15.5Kg / 1.29CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 44 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 125.5 100 125.2 TB1 LED 3 2 1 1 2 3 TB2 4 3 2 1 Assignment Assignment FG AC/N AC/L 1,2 3,4 Block Diagram EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING FG O.L.P. +V -V CONSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. O.T.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 230VAC 90 80 80 60 70 110VAC 60 40 50 20 40 -10 0 10 20 30 40 50 55 60 70 (VERTICAL) Vin: -- 230VAC 110VAC 85 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 45 480W Single Phase POWER SUPPLIES 480W 220V AC Single Output DIN Rail Power Supply with PFC Function Cat. No. 220V ONLY Output V DC A Tol. % Ripple & Noise Efficiency PSP-48024 24V DC 20A ±1% 120 mVp-p 89% PSP-48048 48V DC 10A ±1% 120 mVp-p 89% NOTES 480W Switch Select 110/220V AC Single Output DIN Rail Power Supply with PFC Function 110/220V SWITCH SELECT 46 Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PSP-480S24 24V DC 20A ±1% 120 mVp-p 89% PSP-480S48 48V DC 10A ±1% 120 mVp-p 89% NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS PSP-480 Series (220V AC input only) TB1 Terminal Pin. No Assignment Pin No. Assignment 1 2 3 12 5.2 7 22 10 0 AC/L AC/N FG TB2 Terminal Pin. No Assignment Pin No. Assignment 1,2 3,4 DC OUTPUT +V DC OUTPUT -V Wide range Input: 180-264V AC only, 250-370V DC, 4A @ 230V AC Built in passive Power Factor Correction function compliance to EN61000-3-2, PF>0.7 Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 227x125x100mm (8.95x4.95x3.95 inches) Packaging: 1/box; 5.3lbs / 2.4Kg PSP-480 with Switch Series (110V AC and 220V input AC) TB1 Terminal Pin. No Assignment Pin No. Assignment 1 2 3 12 5.2 7 22 10 0 AC/L AC/N FG TB2 Terminal Pin. No Assignment Pin No. Assignment 1,2 3,4 DC OUTPUT +V DC OUTPUT -V Switch select Input: 90-132V AC / 180-264 V AC, 254-370V DC range 8A @ 115V AC, 3.2A @ 230V AC Built in passive Power Factor Correction function compliance to EN61000-3-2, PF>0.7/230V AC only Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 227x125x100mm (8.95x4.95x3.95 inches) Packaging: 1/box; 5.8lbs / 2.6Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 47 PSP-480 Series Specifications 220V ONLY OUTPUT Features: • Built-in passive PFC function compliance to EN61000-3-2 • High efficiency 89% and low dissipation • Protections: Short Circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL 508(industrial control equipment)approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • 3 year warranty Cat. No. PSP-48024 PSP-48048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 20A 0 ~ 20A 480W 120mVp-p 48V 10A 0 ~ 10A 480W 120mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±0.5% ±1.0% 1200ms, 40ms / 230VAC at full load 16ms / 230VAC VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 180 ~ 264 VAC by switch 250 ~ 370VDC 47 ~ 63Hz ≥0.7 89% 4A / 230VAC COLD START 27A / 115VAC 45A / 230VAC ≤ 3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 48 ~ 53V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION ±0.5% ±1.0% Protection type: Constant current limiting, recovers automatically after fault condition is removed 54 ~ 60V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 100˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT SAFETY & EMC WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 95% RH non-condensing -20 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22); Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-6-2 (EN50082-2); heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY OTHERS The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 180.9K hrs min. MIL-HDBK-217K (25˚C) 227x125.2x100mm (WxHxD) 2.4Kg; 6pcs / 15Kg / 1.75CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 48 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 125.2 227 TB1 3 2 1 LE D TB1 Terminal Pin. No Assignment Pin No. 1 2 3 TB2 4 3 2 1 TB2 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Block Diagram EMI FILTER I/P RECTIFIERS & FILTER PASSIVE PFC RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. O.T.P. Derating Curve CURRENT LIMIT PWM CONTROL O.V.P. Output Derating VS Input Voltage 100 100 90 LOAD (%) LOAD (%) 80 60 40 80 70 60 50 20 -20 40 0 10 20 30 40 50 60 70 (VERTICAL) 180 190 200 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 49 PSP-480S Series Specifications 110/220V SWITCH SELECT OUTPUT Features: • AC input range selectable by switch • Built-in passive PFC function compliance to EN61000-3-2 • High efficiency 89% and low dissipation • Protections: Short Circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL 508(industrial control equipment)approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • 3 year warranty Cat. No. PSP-480S24 PSP-480S48 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 20A 0 ~ 20A 480W 120mVp-p 48V 10A 0 ~ 10A 480W 120mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±0.5% ±0.5% ±1.0% ±1.0% 1200ms, 40ms / 230VAC 1200ms, 40ms / 115VAC at full load 23ms / 230VAC 23ms / 115VAC at full load VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 90 ~ 132VAC / 180 ~ 264 VAC by switch 254 ~ 370VDC 47 ~ 63Hz ≥0.7 / 230VAC only 89% 8A / 115VAC 3.2A / 230VAC COLD START 27A / 115VAC 45A / 230VAC ≤ 3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION Protection type: Constant current limiting, recovers automatically after fault condition is removed 59 ~ 66V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE ENVIRONMENT SAFETY & EMC 100˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25˚C / 70% RH Compliance to EN55011 (CISPR11); EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2 (EN50082-2); heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS that it still meets EMC directives. MTBF DIMENSION PACKING 187.9K hrs min. MIL-HDBK-217K (25˚C) 227x125.2x100mm (WxHxD) 2.6Kg; 6pcs / 16.6Kg / 1.75CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 50 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 56.6 227 10 6 125.2 12 230VAC 115VAC TB1 3 2 1 LE D TB1 Terminal Pin. No Assignment Pin No. 1 2 3 TB2 4 3 2 1 TB2 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Block Diagram 230 115 EMI FILTER I/P RECTIFIERS & FILTER PASSIVE PFC POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT FG O.L.P. O.T.P. CURRENT LIMIT PWM CONTROL Derating Curve O.V.P. Output Derating VS Input Voltage 100 100 180 ~ 264VAC 90 ~ 132VAC 90 80 LOAD (%) LOAD (%) 80 60 40 20 -20 +V -V 70 60 50 40 0 10 20 30 40 50 60 70 (VERTICAL) 90 180 100 190 115 230 132 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 51 240-960W Three Phase POWER SUPPLIES 240W Three Phase Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PST-24024 24V DC 10A ±1% 80 mVp-p 89% PST-24048 48V DC 5A ±1% 80 mVp-p 89% NOTES 480W Three Phase Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PST-48024 24V DC 20A ±1% 80 mVp-p 89% PST-48048 48V DC 10A ±1% 80 mVp-p 90% NOTES 960W Three Phase Industrial DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PST-96024 24V DC 40A ±1% 80 mVp-p 91% PST-96048 48V DC 20A ±1% 80 mVp-p 92% NOTES 960W Three Phase Industrial DIN Rail Power Supply with PFC and Parallel Function (1+1) Cat. No. 52 Output V DC A Tol. % Ripple & Noise Efficiency PST-960P24 24V DC 40A ±1% 80 mVp-p 91% PST-960P48 48V DC 20A ±1% 80 mVp-p 92% NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS PST-240 Series TB1 Terminal Pin. No Assignment 12 Pin No. 1 2 3 4 5.2 10 TB2 Terminal Pin. No Assignment Pin No. 1,2 3,4 Assignment DCOUTPUT +V DCOUTPUT -V Three phase input: 340-550V AC wide range, 480-780V DC 0.95A @ 400V AC, 0.75A @ 500V AC Connection: Input - 4 poles, Output – 4 poles screw terminal Size (WxHxD): 125x125x100mm (4.95x4.95x3.95 inches) Packaging: 1/box; 2.87lbs / 1.3Kg 5.5 12 0 Assignment FG AC/L3 AC/L2 AC/L1 PST-480 Series TB1 Terminal Pin. No Assignment Pin No. 1 2 3 4 12 5.2 27 2 10 0 Assignment AC/L1 AC/L2 AC/L3 FG TB2 Terminal Pin. No Assignment Pin No. 1,2 3,4 Assignment DCOUTPUT +V DCOUTPUT -V Three phase input: 340-550V AC wide range, 480-780V DC 1.7A @ 400V AC, 1.3A @ 500V AC Connection: Input - 4 poles, Output – 4 poles screw terminal Size (WxHxD): 227x125x100mm (9.95x4.95x3.95 inches) Packaging: 1/box; 5.5lbs / 2.5Kg PST-960 Series TB1 Terminal Pin. No Assignment Pin No. 1 2 3 4 12 5.2 6 27 10 0 Assignment AC/L1 AC/L2 AC/L3 FG TB2 Terminal Pin. No Assignment Pin No. 1,2,3 4,5,6 7 8 Assignment DCOUTPUT+ V DCOUTPUT - V GND P (Current Share) } Parallel Only Three phase input: 340-550V AC wide range, 2.4A @ 400V AC, 1.9A @ 500V AC Connection: Input - 4 poles, Output – 6 poles screw terminal Size (WxHxD): 276x125x100mm (10.87x4.95x3.95 inches) Packaging: 1/box; 7.3lbs / 3.3Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 53 PST-240 Series Specifications OUTPUT Features: • Three-Phase AC 340 ~ 550V wide range input • High efficiency 89% and low dissipation • Protections: Short Circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL 508(industrial control equipment)approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • Fixed switching frequency at 70KHz • 3 year warranty Cat. No. PST-24024 PST-24048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 10A 0 ~ 10A 240W 80mVp-p 48V 5A 0 ~ 5A 240W 80mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME ±0.5% ±0.5% ±0.5% ±0.5% 1200ms, 40ms, 20ms / 400VAC; 800ms, 40ms, 40ms / 500VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT Three Phase 340 ~ 550VAC (Dual Phase operation possible) Dual phase operation: derating of 20% is required 47 ~ 63Hz 89% 0.95A / 400VAC; 0.75 / 500VAC COLD START 50A ≤ 3.5 mA / 530VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION 480 ~ 780VDC Protection type: Constant current limiting, recovers automatically after fault condition is removed 59 ~ 66V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 100˚C ± 5˚C (TSW) detect on heat sink of power switch Protection type: Shut down overvoltage, re-power automatically after temperature goes down ENVIRONMENT SAFETY & EMC WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 114.6K hrs min. MIL-HDBK-217K (25˚C) 125.5x125.2x100mm (WxHxD) 1.3Kg; 12pcs / 16.6Kg / 1.29CUFT All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25˚C of ambient temperature. 54 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 125.5 125.5 TB1 4 3 2 1 LE D TB2 4 3 2 1 TB1 Terminal Pin. No Assignment Pin No. 1 2 3 4 TB2 Terminal Pin. No Assignment Assignment FG AC/L3 AC/L2 AC/L1 Assignment DC OUTPUT +V DC OUTPUT -V Pin No. 1,2 3,4 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL Derating Curve O.V.P. Output Derating VS Input Voltage 100 100 90 80 LOAD (%) LOAD (%) 80 60 40 20 -20 Three phase operation Dual phase operation 70 60 50 40 0 10 20 30 40 50 60 70 (VERTICAL) 340 355 370 385 400 415 430 460 475 490 505 520 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 55 PST-480 Series Specifications OUTPUT Features: • Three-Phase AC 340 ~ 550V wide range input • High efficiency 89% and low dissipation • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL 508(industrial control equipment)approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • 3 year warranty Cat. No. PST-48024 PST-48048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 20A 0 ~ 20A 480W 80mVp-p 48V 10A 0 ~ 10A 480W 80mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME ±0.5% ±0.5% ±0.5% ±0.5% 1200ms, 40ms, 16ms / 400VAC; 800ms, 40ms, 35ms / 500VAC at full load VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT Three Phase 340 ~ 550VAC (Dual Phase operation possible) Dual phase operation: derating of 20% is required 47 ~ 63Hz 89% 90% 1.7A / 400VAC; 1.3A / 500VAC COLD START 50A ≤ 3.5mA / 530VAC OVERLOAD 105 ~ 150% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT PROTECTION 480 ~ 780VDC Protection type: Constant current limiting, recovers automatically after fault condition is removed 59 ~ 66V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 110˚C ± 5˚C (TSW) detect on heat sink of power switch Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT SAFETY & EMC WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25˚C: 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 91.1K hrs min. MIL-HDBK-217K (25˚C) 227x125.2x100mm (WxHxD) 2.5Kg; 6pcs / 16Kg / 1.75CUFT All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25˚C of ambient temperature. 56 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 125.2 227 TB1 4 3 2 1 TB2 4 3 2 1 LED TB1 Terminal Pin. No Assignment Pin No. 1 2 3 4 TB2 Terminal Pin. No Assignment Assignment AC/L1 AC/L2 AC/L3 FG Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL Derating Curve Output Derating VS Input Voltage 100 100 Three phase operation 90 85 80 LOAD (%) 80 LOAD (%) O.V.P. 60 40 Dual phase operation 70 60 50 20 -20 40 0 10 20 30 40 50 60 70 (VERTICAL) 340 355 370 385 400 415 430 460 475 490 505 520 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 57 PST-960 Series Features: Specifications OUTPUT • Three-Phase AC 340 ~ 550V wide range input • High efficiency 91% and low dissipation • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Optional parallel function(1+1) • Cooling by free air convection • DIN rail mountable • UL 508(industrial control equipment) approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • 3 year warranty Cat. No. PST-96024 / PST-960P24* PST-96048 / PST-960P48* DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 40A 0 ~ 40A 960W 80mVp-p 48V 20A 0 ~ 20A 960W 80mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME 24 ~ 28V 48 ~ 55V ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. ±0.5% ±0.5% ±0.5% ±0.5% 200ms, 60ms, 14ms / 400VAC 200ms, 60ms, 30ms / 500VAC at full load VOLTAGE RANGE Three Phase 340 ~ 550VAC (Dual Phase operation possible in connecting L1, L3, FG) FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 91% 2A / 400VAC; COLD START 50A ≤ 3.5 mA / 530VAC OVERLOAD 105 ~ 125% rated output power OVERVOLTAGE 30 ~ 36V Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. INPUT Dual phase operation (connecting L1, L3, FG) is allowed under certain derating to output load. Please refer to the derating curves for details. PROTECTION 92% 1.6A / 500VAC Protection type: Constant current limiting, unit will shut down overvoltage after 3 sec., re-power on to recover 59 ~ 66V Protection type: Shut down overvoltage, re-power on to recover ENVIRONMENT SAFETY & EMC OVERTEMPERATURE 110˚C ± 5˚C (TSW1) detect on heat sink of power transistor 85˚C ± 5˚C (TSW2) detect on heat sink of power diode Protection type: Shut down overvoltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS that it still meets EMC directives. MTBF DIMENSION PACKING 122.5K hrs min. MIL-HDBK-217K (25˚C) 276x125.2x100mm (WxHxD) 3.3Kg; 4pcs / 14.2Kg / 1.14CUFT All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25˚C of ambient temperature. *Special order required. 58 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 125.2 276 TB1 4 3 2 1 TB2 6 5 4 3 2 1 ALARM LE D TB1 Terminal Pin. No Assignment Pin No. 1 2 3 4 TB2 Terminal Pin. No Assignment Pin No. 1,2,3 4,5,6 7 8 Assignment AC/L1 AC/L2 AC/L3 FG Assignment DCOUTPUT+ V DCOUTPUT - V P (Current Share) P (Current Share) } Parallel Only Optional Parallel Function (1+1) - (Special order required) PSU PSU TB2 8 7 6 5 4 3 2 1 TB1 4 3 2 1 TB2 8 7 6 5 4 3 2 1 TB1 4 3 2 1 LED LED +V -V LOAD Block Diagram RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT O.T.P. FG CURRENT LIMIT PHASE-SHIFT O.V.P. Output Derating VS Input Voltage Derating Curve 100 100 Three phase operation 90 80 LOAD (%) LOAD (%) 80 60 50 40 20 -20 Dual phase operation 70 60 50 40 0 10 20 30 40 45 50 60 70 (VERTICAL) 340 355 380 385 400 415430 460 475 490 505 520 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 59 High Efficiency Compact Housing Power Supply This high performance single output compact DIN rail PS-C Series, with up-to-date circuit design, possess up to 94% of high efficiency and works within 110 ~150% rated output power for up to 3 seconds. With built-in active PFC function, PS-C Series is a full range AC input switching power supply that fulfills the requirement of EN61000-3-2 for harmonic current. The compact design helps save the precious space on the rail and also makes it up to 50% smaller in size compare to its predecessor model PS-Series. Meanwhile, PS-C also have 5~9% higher efficiency than corresponding models of the PS-Series, which response to the trend of green power with energy saving concept. Other standard functions include DC OK relay contact, on panel LED indicator, and protection for short-circuit, overload (constant current limiting, shut down if over 3 seconds), over voltage, and over temperature. To fulfill the requirements of marine and semi-conductor related usage, PS-C Series also complies with GL and SEMI F47 norms in addition to UL, CUL and CE certificates. Suitable applications are factory automation, semi-conductor fabrication equipment, marine related installation, and electromechanical applications. • Input voltage range: • AC inrush current (typical):Cold start: • DC adjustment range (typical): • Overload protection (typical): • Overvoltage protection (typical): • Over temperature protection: • Withstand voltage: Working temperature: Safety standards: EMC standards: 60 88-264V AC; 124-370V DC 65A at 230V AC (PSC-240) 12V: 12-14V, 24V: 24-28V, 48V: 48-55V, 110%-150% rated output power 14-17V for 12V model (PSW-120), 29-33V for 24V model 56-65V for 48V model 95˚C ± 5˚C (PSC-120/240); 105˚C ± 5˚C I/P-O/P:3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC, -25 to +70°C (-4° to +158°F), refer to output derating curve UL508; EN60950-1 compliant Compliance to EN55022 class B, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2, EN61204-3, heavy Industry level, SEMI F47, GL For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. PS-C Series ENERGY SAVER Features: • High efficiency up to 94% and low power dissipation • Universal AC Input / Full Range • 150% peak load capability • Built-in active PFC function, PF>0.93 • Protections: Short circuit / Overload / Overvoltage / Over temperature • Cooling by free air convection • Din rail mountable • LED indicator for power on • UL 508 (industrial control equipment) approved • EN61000-6-2(EN50082-2) industrial immunity level • 100% full load burn-in test • Built-in DC OK relay contact • 3 year warranty 35mm DIN Rail Mounting Adjustable DC Output Voltage DC on LED signal Easy to understand layout panel Rugged metal housing CE Compliance UL508 Compliance Universal Input Narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 61 120-480W Single Phase COMPACT SIZE POWER SUPPLIES ENERGY SAVER 120W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-C12012 12V DC 10A ±1% 100 mVp-p 89% PS-C12024 24V DC 5A ±1% 100 mVp-p 91% PS-C12048 48V DC 2.5A ±1% 120 mVp-p 91% NOTES 240W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-C24024 24V DC 10A ±1% 100 mVp-p 94% PS-C24048 48V DC 5A ±1% 120 mVp-p 94% NOTES 480W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PS-C48024 24V DC 20A ±1% 100 mVp-p 94% PS-C48048 48V DC 10A ±1% 120 mVp-p 94% NOTES 480W Single Output DIN Rail Power Supply with PFC and Parallel Function (1+7) Cat. No. 62 Output V DC A Tol. % Ripple & Noise Efficiency PS-C480P24 24V DC 20A ±1% 100 mVp-p 94% PS-C480P48 48V DC 10A ±1% 120 mVp-p 94% NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS PS-C120 Series Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. Assignment Relay Contact 1,2 DC OUTPUT -V 3 DC OUTPUT +V 4 Assignment FG AC/N AC/L 5.2 12 11 3.5 40 Universal Input: 88-264V AC, 124-370V DC full range, 1.4A/115V AC, 0.7A/230V AC Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 40x125.2x113.5mm (1.57x4.93x4.47 inches) Packaging: 1/box; 1.48lbs / 0.67Kg PS-C240 Series Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 5.2 12 11 3.5 63 Assignment FG AC/N AC/L Terminal Pin. No Assign. (TB2) Pin No. Assignment Relay Contact 1,2 DC OUTPUT -V 3,4 DC OUTPUT +V 5,6 Switch select Input: 88-264V AC, 124-370V DC range, 2.6A/115V AC, 1.3A/230V AC Connection: Input - 3 poles, Output – 6 poles screw terminal Size (WxHxD): 63x125.2x113.5mm (2.48x4.93x4.47 inches) Packaging: 1/box; 2.27lbs / 1.03Kg PS-C480 Series Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L 5.2 Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1,2 DC OUTPUT -V 3,4 Relay Contact 5,6 NC 7,8 12 For Parallel Model Terminal Pin. No Assign. (TB1) 12 8.5 .5 85 Pin No. 1 2 3 Assignment FG AC/N AC/L For Parallel Model Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V DC OUTPUT -V 3,4 Relay Contact 5,6 P+ (current share)* 7 P- (current share)* 8 * Only parallel function. Universal Input: 90-264V AC, 127-370V DC full range, 5A/115V AC, 2.5A/230V AC Connection: Input - 3 poles, Output – 12 poles screw terminal Size (WxHxD): 85.5x125.2x128.5mm (3.37x4.93x5.06 inches) Packaging: 1/box; 3.53lbs / 1.6Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 63 Features: PS-C120 Series • High efficiency 91% and low power dissipation • 150% peak load capability • Built-in active PFC function, PF>0.93 • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • DIN rail mountable • UL 508 (industrial control equipment) approved • EN61000-6-2 (EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty Specifications ENERGY SAVER OUTPUT Cat. No. PS-C12012 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 12V 24V 10A 5A 0 ~ 10A 0 ~ 5A 120W 120W 15A 7.5A 180W (3 sec.) 3 seconds max., please refer to peak loading curves 100mVp-p 100mVp-p RIPPLE & NOISE (max) PS-C12024 PS-C12048 48V 2.5A 0 ~ 2.5A 120W 3.75A 120mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 14V ±1.0% 24 ~ 28V ±1.0% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 1500ms, 60ms / 230VAC 20ms / 230VAC 88 ~ 264VAC ±0.5% ±1.0% 3000ms, 60ms / 115VAC at full load 20ms / 115VAC at full load ±0.5% ±1.0% 124 ~ 370VDC Deating may be needed under low input voltages, please check the derating curve for more detail PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 0.93 / 230VAC 0.96 / 115VAC at full load 89% 91% 1.4A / 115VAC 0.7A / 230VAC 35A / 115VAC 70A / 230VAC ≤ 1 mA / 240VAC OVERLOAD Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage ≥ 150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down overvoltage after 3 seconds 14 ~ 17V 29 ~ 33V 56 ~ 65V OVERVOLTAGE 90.50% Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 95˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, re-power automatically after temperature goes down DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A ENVIRONMENT WORKING TEMP. 30VDC / 1A 30VAC / 0.5A RESISTIVE LOAD -25 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING 20 ~ 95% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY OTHERS The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 289.9K hrs min. MIL-HDBK-217K (25˚C) 40x125.2x113.5mm (WxHxD) 0.67Kg; 20pcs / 14.4Kg / 1.16CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 64 12 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 113. 5 TB2 1 2 3 4 40 +V ADJ. Assignment FG AC/N AC/L Assignment 1,2 3 4 TB1 1 2 3 125.2 1 2 3 + DC OK Relay Contact age. Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.C.P. U.V.P. O.L.P. FG DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Peak Loading 180W 180W 120W 60W Derating Curve Output Derating VS Input Voltage Others 150 100 90 112.5 12V Others 100 80 70 60 Continuous 75 12V 50 60 40 -25 0 10 20 30 40 50 55 60 70 (VERTICAL) 88 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 65 12 PS-C240 Series Features: Specifications ENERGY SAVER OUTPUT • High efficiency 94% and low power dissipation • 150% peak load capability • Built-in active PFC function, PF>0.93 • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • DIN rail mountable • UL 508 (industrial control equipment) approved • EN61000-6-2(EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty Cat. No. PS-C24024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 48V 10A 5A 0 ~ 10A 0 ~ 5A 240W 240W 15A 7.5A 360W (3 sec.) 3 seconds max., please refer to peak loading curves 100mVp-p 120mVp-p RIPPLE & NOISE (max) PS-C24048 Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±1.0% 1500ms, 60ms / 230VAC 20ms / 230VAC 88 ~ 264VAC ±0.5% ±1.0% 3000ms, 60ms / 115VAC at full load 20ms / 115VAC at full load 124 ~ 370VDC Deating may be needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) PROTECTION AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE 47 ~ 63Hz 0.93 / 230VAC 0.99 / 115VAC at full load 94% After 30 minutes of burn-in. 2.6A / 115VAC 1.3A / 230VAC 33A / 115VAC 65A / 230VAC ≤ 1 mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery ≥ 150% rated power, constant current limiting with autorecovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V Protection type: Shut down overvoltage with auto-recovery OVERTEMPERATURE 95˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, re-power automatically after temperature goes down ENVIRONMENT DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A 30VDC / 1A 30VAC / 0.5A RESISTIVE LOAD WORKING TEMP. -25 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY OTHERS 20 ~ 95% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 169.3K hrs min. MIL-HDBK-217K (25˚C) 63x125.2x113.5mm (WxHxD) 1.03Kg; 12pcs / 13.4Kg / 1.06CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 66 12 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 113. 5 TB2 1 2 3 4 5 6 Mechanical Specification 1 TB1 3 Assignment 1,2 3,4 5,6 2 Assignment FG AC/N AC/L 1 2 3 + 125.2 +V ADJ. 63 DC OK Relay Contact age. Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.C.P. U.V.P. O.L.P. FG DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Peak Loading 360W 360W 240W 120W Derating Curve Output Derating VS Input Voltage 100 150 90 112.5 80 100 70 60 Continuous 75 50 60 40 -25 0 10 20 30 40 50 60 70 (VERTICAL) 88 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 67 12 PS-C480 Series Features: • High efficiency 94% and low power dissipation • 150% peak load capability • Built-in active PFC function, PF>0.94 • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL 508(industrial control equipment) approved • EN61000-6-2(EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty Specifications ENERGY SAVER OUTPUT Cat. No. PS-C48024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 48V 20A 10A 0 ~ 20A 0 ~ 10A 480W 480W 30A 15A 720W (3 sec.) 3 seconds peak power max. and the average output power should not exceed the rate power 100mVp-p 120mVp-p RIPPLE & NOISE (max) PS-C48048 Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.2% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±0.5% ±0.5% ±1.0% ±1.0% 1500ms, 150ms / 230VAC 3000ms, 150ms / 115VAC at full load 14ms / 230VAC at full load 90 ~ 264VAC 127 ~ 370VDC Deating may be needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) 47 ~ 63Hz 0.94 / 230VAC 94% 0.99 / 115VAC at full load After 30 minutes of burn-in PROTECTION AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE 5A / 115VAC 2.5A / 230VAC 40A / 115VAC 80A / 230VAC ≤ 0.8 mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery ≥ 150% rated power, constant current limiting with auto-recovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V Protection type: Shut down overvoltage with auto-recovery on re-power on to recovery OVERTEMPERATURE 105˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, re-power automatically after temperature goes down ENVIRONMENT DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. -25 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY OTHERS 20 ~ 95% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 112.9K hrs min. MIL-HDBK-217K (25˚C) 85.5x125.2x128.5mm (WxHxD) 1.6Kg; 8pcs / 13.8Kg / 0.9CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 68 12 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification TB2 1 2 3 4 5 6 7 8 128.5 Assignment 1,2 3,4 5,6 7,8 3 TB1 2 + +V ADJ NC 1 Assignment FG AC/N AC/L 125.2 1 2 3 85.5 DC OK Relay Contact age. Block Diagram I/P POWER SWITCHING PFC CIRCUIT & RECTIFIERS RECTIFIERS & FILTER +V -V O.C.P. U.V.P. O.L.P. DETECTION CIRCUIT FG PFC CONTROL CONTROL O.V.P. Peak Loading 720W 720W 480W 240W Derating Curve Output Derating VS Input Voltage 100 150 90 120 80 100 70 60 Continuous 80 50 60 40 -25 0 10 20 30 40 50 60 70 (VERTICAL) 90 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 69 12 PS-C480P Series Features: • High efficiency 94% and low power dissipation • 150% peak load capability • Built-in active PFC function, PF>0.94 • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • Current sharing up to 380W (1+7) • UL 508(industrial control equipment)approved • EN61000-6-2(EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty With Parallel Function Specifications ENERGY SAVER OUTPUT Cat. No. PS-C480P24 PS-C480P48 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER 24V 20A 0 ~ 20A 480W 30A 720W (3 sec.) 48V 10A 0 ~ 10A 480W 15A 3 seconds peak power max. and the average output power should not exceed the rate power RIPPLE & NOISE (max) 100mVp-p 120mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.2% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE ±0.5% ±1.0% 1500ms, 150ms, 14ms / 230VAC 90 ~ 264VAC ±0.5% ±1.0% 3000ms, 150ms / 115VAC at full load 127 ~ 370VDC Deating may be needed under low input voltages, please check the derating curve for more detail FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) 47 ~ 63Hz 0.94 / 230VAC 94% 0.99 / 115VAC at full load After 30 minutes of burn-in. PROTECTION AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 5A / 115VAC 2.5A / 230VAC 40A / 115VAC 80A / 230VAC ≤ 0.6 mA / 240VAC OVERLOAD Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery ≥ 150% rated power, constant current limiting with auto-recovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V OVERVOLTAGE Protection type: Shut down overvoltage with auto-recovery on re-power on to recovery OVERTEMPERATURE 105˚C ± 5˚C (TSW: detect on heat sink of power switch) Protection type: Shut down overvoltage, re-power automatically after temperature goes down ENVIRONMENT CURRENT SHARING Please see function diagram DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. -25 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING 20 ~ 95% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥100M Ohms/500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. OTHERS MTBF DIMENSION PACKING 112.9K hrs min. MIL-HDBK-217K (25˚C) 85.5x125.2x128.5mm (WxHxD) 1.6Kg; 8pcs / 13.8Kg / 0.9CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. 70 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 85.5 Terminal Pin No. Assignment (TB2) DC OK Assignment DC OUTPUT +V DC OUTPUT -V Relay Contact P+ (current share) P- (current share) DC OK TB1 3 +V A D J 1 + 2 Pin No. 1,2 3,4 5,6 7 8 Assignment FG AC/N AC/L 125.2 Terminal Pin No. Assignment (TB1) Pin No. 1 2 3 TB2 1 2 3 4 5 6 7 8 128.5 DC OK Relay Contact Peak Loading (1) 720W Contact Close When the output voltage reaches the adjusted output volt age. Contact Open When the output voltage drop below 90% output voltage. Contact Ratings (max.) 30V/1A resistive load (2) 720W 480W 240W 50 sec. 3 sec. 15 sec. 3 sec. DC OK Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.C.P. U.V.P. O.L.P. FG DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Function Diagram 1. Current sharing (1)Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required. (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 8 units is the maximum, please consult the manufacture for other applications. (5) When in parallel operation, the minimum output load should be greater than 3% of total output load. (Min. load > 3% rated current per unit x number of unit) + LOAD - + - DC OK P+ P- + - DC OK P+ P- + - DC OK P+ P- + - DC OK P+ P- + - DC OK P+ P- + - DC OK P+ P - + - DCOK P+ P - + - DCOK P+ P - PSU PSU PSU PSU PSU PSU PSU PSU Derating Curve Output Derating VS Input Voltage 100 150 90 For3 sec. (typ.) 120 80 70 100 60 Continuous 80 50 60 -25 40 0 10 20 30 40 50 60 70 (VERTICAL) 90 100 110 135 155 230 264 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 71 Wide Input Compact Housing Power Supply With the PSW family, AC/DC compact DIN rail switching power supplies with single phase wide input range, Altech further expanded the power supply line. Built-in active PFC function, these high efficient power units meet the harmonic current limitation per EN61000-3-2. Equipped with 180 to 550Vac single phase wide input range, they can be used in general power system applications with single phase 230Vac input or can capture two phases from the 220~550Vac three-phase power system, which can greatly increase the flexibility of system deployment. With up-to-date circuit design PSW series possess up to 93% of extremely high efficiency and can provide 100% power continuously at 50*C by only free air convection, or operate under 70*C ambient temperature by suitable power derating. The compact design in width helps save the precious space on the rail and also makes it up to 50% smaller in size compare to its predecessor models. Meanwhile, with wider input range the PSW series also has 3% higher efficiency than corresponding models, which response to the trend of green power with energy saving concept. Other standard functions include DC OK relay contact alarm signal output, front panel DC voltage adjustment , as well as protection for short-circuit, overload (constant current mode, shut down if over 3 seconds), over voltage, and over temperature. The PSW series comply with UL508, IEC60950-1 (CB), and CE certificates and also meet the EMC requirements of heavy industrial immunity level (EN61000-6-2). Suitable applications include industrial control system, semi-conductor fabrication equipment, factory automation, electromechanical applications, and marine related installation. • Input voltage range: 180~550V AC; 254-780V DC • AC inrush current (typical):Cold start: 50A at 400V AC • DC adjustment range (typical): 12V: 12-15V, 24V: 24-29V, 48V: 48-58V, • Overload protection (typical): 105%-130% rated output • Over-voltage protection (typical): 16-18V for 12V model (PSW-120), 31-37V for 24V model; 60-67V for 48V model • Setup, rise, time (typical): 2000ms, 70ms at full load and 230V AC (PSW-120) 2000ms, 150ms at full load and 230V AC (PSW240/480) • Withstand voltage: I/P-O/P:3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC, • Working temperature: -20 to +70°C (-4° to +158°F), refer to output derating curve (PSW-120) • DC OK signal Relay contact • Safety standards: UL508 (PSW-240 pending) • EMC standards: Compliance to EN55011 (CISPR11), EN55022 class B, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy Industry Level criteria A • Military standard: MIL-HDBK-217K For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 72 12 PSW Series SAVER ENERGY ENERGY SAVER • • • • • • • • • • • Single and two phase wide input range 180~550VAC Universal AC Input / Full Range High efficiency up to 93% and low power dissipation Protections: Short circuit / Overload / Overvoltage / Over temperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty Multible output connector for easy wiring 35mm DIN Rail Mounting Adjustable DC Output Voltage DC on LED signal Easy to understand layout panel Rugged metal housing CE Compliance UL508 Compliance Universal Input Narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 73 12 120-480W Single Phase WIDE INPUT POWER SUPPLIES SAVER ENERGY ENERGY SAVER 120W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PSW-12012 12V DC 10A ±1.5% 120 mVp-p 89.5% PSW-12024 24V DC 5A ±1% 120 mVp-p 91% PSW-12048 48V DC 2.5A ±1% 150 mVp-p 92% NOTES 240W Single Output DIN Rail Power Supply Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PSW-24024 24V DC 10A ±1% 120 mVp-p 90% PSW-24048 48V DC 5A ±1% 120 mVp-p 90% NOTES 480W Single Output DIN Rail Power Supply (Also available with Optional Parallel Function (7+1)) Cat. No. Output V DC A Tol. % Ripple & Noise Efficiency PSW-48024 24V DC 20A ±1% 100 mVp-p 94% PSW-48048 48V DC 10A ±1% 120 mVp-p 94% NOTES For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 74 12 SPECIFICATIONS PSW-120 Series 40 113.5 125.2 3 AC/L1 2 AC/L2 1 FG Pin No. Assignment 4 DC OUTPUT +V 3 DC OUTPUT -V 1,2 Relay Contact Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 5.2 12 11 3.5 Terminal Pin. No Assign. (TB2) Pin No. Assignment Relay Contact 1,2 DC OUTPUT -V 3 DC OUTPUT +V 4 Assignment FG AC/L2 AC/L1 Universal Input: 180-550V AC, 254-780V DC full range, 0.55A/400V AC, 1.2A/230V AC Connection: Input - 3 poles, Output – 4 poles screw terminal Size (WxHxD): 40x125.2x113.5mm (1.57x4.93x4.47 inches) Packaging: 1/box; 1.433lbs / 0.65Kg 40 PSW-240 Series 63 113.5 125.2 3 AC/L1 2 AC/L2 1 FG Pin No. Assignment 5,6 DC OUTPUT +V 3,4 DC OUTPUT -V 1,2 Relay Contact Pin No. Assignment Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 5.2 12 11 3.5 Terminal Pin. No Assign. (TB2) Pin No. Assignment Relay Contact 1,2 DC OUTPUT -V 3,4 DC OUTPUT +V 5,6 Assignment FG AC/L2 AC/L1 Universal Input: 180-550V AC, 254-780V DC full range, 1A/400V AC, 2A/230V AC Connection: Input - 3 poles, Output – 6 poles screw terminal Size (WxHxD): 63x125.2x113.5mm (2.48x4.93x4.47 inches) Packaging: 1/box; 2.337lbs / 1.06Kg 63 * Only parallel function. 3 AC/L1 2 AC/L2 1 FG Pin No. Assignment Terminal Pin. No Assign. (TB1) For Parallel Model 3 AC/L 2 AC/N 1 FG Pin No. Assignment Terminal Pin. No Assign. (TB1) PSW-480 Series 85.5 128.5 125.2 5,6 Relay Contact 3,4 DC OUTPUT -V 1,2 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB2) For Parallel Model 5,6 Relay Contact 3,4 DC OUTPUT -V 1,2 DC OUTPUT +V Pin No. Assignment Terminal Pin. No Assign. (TB2) Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 For Parallel Model Terminal Pin. No Assign. (TB1) Pin No. 1 2 3 5.2 12 Assignment FG AC/L2 AC/L1 Terminal Pin. No Assign. (TB2) Pin No. Assignment DC OUTPUT +V 1,2 DC OUTPUT -V 3,4 Relay Contact 5,6 Assignment FG AC/N AC/L For Parallel Model Terminal Pin. No Assign. (TB2) Pin No. Assignment 1,2 DC OUTPUT +V DC OUTPUT -V 3,4 Relay Contact 5,6 * Only parallel function. 12 8.5 8 5.5 Universal Input: 180-550V AC, 254-780V DC full range, 1.6A/400V AC, 4A/230V AC Connection: Input - 3 poles, Output – 12 poles screw terminal Size (WxHxD): 85.5x125.2x128.5mm (3.37x4.93x5.06 inches) Packaging: 1/box; 3.748lbs / 1.7Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 75 12 PSW-120 Series Features: Specifications SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT • Single and two phase wide input range 180 ~ 550VAC • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • Built-in constant current limiting circuit • DIN rail mountable • UL508 (industrial control equipment) approved • EN61000-6-2 (EN50082-2) industrial immunity level • 100% full load burn-in test • Built-in DC OK relay contact • 3 year warranty Cat. No. PSW-12012 PSW-12024 PSW-12048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 10A 0 ~ 10A 120W 120mVp-p 24V 5A 0 ~ 5A 120W 120mVp-p 48V 2.5A 0 ~ 2.5A 120W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 12 ~ 15V ±1.5% 24 ~ 29V ±1.0% 48 ~ 58V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION LOAD REGULATION SETUP, RISE HOLD UP TIME ±0.5% ±0.5% 2000ms, 70ms, 50ms / 400VAC ±0.5% ±0.5% ±0.5% ±0.5% 2000ms, 70ms, 10ms / 230VAC at full load INPUT Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quick may lead to increase of the set up time. INPUT PROTECTION PROTECTION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 180 ~ 550VAC 254 ~ 780VDC 47 ~ 63Hz 89.5% / 400V 91% / 400V 0.55A / 400VAC 1.2A / 230VAC COLD START 50A ≤ 3.5 mA / 530VAC 92% / 400V 105 ~ 130% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVERVOLTAGE 16 ~ 18V 31 ~ 37V 60 ~ 67V Protection type: Shut down overvoltage, re-power on to recover OVERTEMPERATURE 105˚C ± 5˚C (12V), 110˚C ± 5˚C (24V) (TSW1) detect on heat sink of power switch transistor; 100˚C ± 5˚C (48V) (TSW1) detect on heat sink of power diode Protection type: Shut down overvoltage, re-power automatically after temperature goes down ENVIRONMENT ENVIRONMENT SAFETY & EMC SAFETY & EMC DC OK SIGNNAL Relay contact rating (max.): 30V / 1A resistive WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -25 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Mounting clip: Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 approved IEC60950-1 compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25˚C; 70% RH) EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A, OTHERS The power supply is considered a component which will installed into a final equipment. The final equipment must be OTHERS re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 268K hrs min. MIL-HDBK-217K (25˚C) 40x125.2x113.5mm (WxHxD) 0.65Kg; 20pcs / 14Kg / 1.16CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 76 -25 0 10 20 30 40 50 60 180 70 (VERTICAL) 190 200 250 290 310360 400 450 490 500 520 550 40 20 50 40 60 12V 60 70 80 80 90 100 Others 100 Derating Curve Static Characteristics O.V.P. CONTROL PWM O.L.P. O.T.P. LIMIT CURRENT FG I/P CIRCUIT DETECTION FILTER & RECTIFIERS FILTER EMI FILTER & RECTIFIERS SWITCHING POWER -V +V DC OK Block Diagram 3 2 1 Pin No. AC/L1 AC/L2 FG Assignment TerminalP in No. Assignment (TB1) 4 3 1,2 Pin No. DC OUTPUT+V DC OUTPUT -V Relay Contact Assignment TerminalP in No. Assignment (TB2) 2.521 1 2 3 1BT 40 DC OK + 1 2 3 4 2BT +V ADJ. DC OK 113. 5 Mechanical Specification Mechanical Specification TB2 1 2 3 4 113. 5 DC OK +V ADJ. + TB1 1 2 3 125.2 DC OK 40 TerminalP inNo. Assignment (TB2) TerminalP inNo. Assignment (TB1) PinNo. 1 2 3 PinNo. Assignment 1,2 RelayContact DC OUTPUT -V 3 DC OUTPUT+V 4 Assignment FG AC/L2 AC/L1 Block Diagram DC OK RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG CURRENT LIMIT PWM CONTROL O.L.P. O.T.P. O.V.P. Derating Curve Static Characteristics Others 100 100 90 80 80 12V 60 70 60 40 50 20 -25 40 0 10 20 30 40 50 60 70 (VERTICAL) 180 190 200 250 290 310360 400 450 490 500 520 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 77 PSW-240 Series Specifications SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT Features: • Single and two phase wide input range 180~550VAC • High efficiency 91% and low power dissipation • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • DIN rail mountable • UL 508 (industrial control equipment) approved • EN61000-6-2 (EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty Cat. No. PSW-24024 PSW-24048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 10A 0 ~ 10A 240W 150mVp-p 48V 5A 0 ~ 5A 240W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT INPUT LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE ±0.5% ±1.0% 800ms, 150ms, 18ms / 400VAC 180 ~ 550VAC ±0.5% ±1.0% 1500ms, 150ms, 18ms / 230VAC at full load 254 ~ 780VDC Derating may be needed under low input voltage. Please check the derating curve for more details PROTECTION PROTECTION FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 47 ~ 63Hz 91% 1A / 400VAC COLD START 50A ≤ 3.5 mA / 530VAC 2A / 230VAC 105 ~ 130% rated output power Protection type: Constant current limiting, unit will shut down after 3 sec.; auto recovery after 1 minute if the fault condition is removed OVERVOLTAGE 29 ~ 33V 56 ~ 65V Protection type: Shut down overvoltage, re-power on to recovery Under over-voltage condition, If input voltage ≤ 200VAC, the power supply will shut down and then may have auto-recovery after several seconds OVERTEMPERATURE ENVIRONMENT ENVIRONMENT 90˚C ± 5˚C (TSW) detect on heat sink of power switch Protection type: Shut down overvoltage, recovers automatically after temperature goes down DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. -30 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING 20 ~ 95% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 approved IEC 60950-1 compliant Design refer to GL I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG :0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: ≥ 100M Ohms / 500VDC (25˚C; 70% RH) EN55022 (CISPR22), Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN 55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A approved; WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS OTHERS MTBF DIMENSION PACKING 141.1K hrs min. MIL-HDBK-217K (25˚C) 63x125.2x113.5mm (WxHxD) 1.06Kg; 12pcs / 13.7Kg / 1.06CUFT All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25˚C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 78 -30 0 10 20 30 40 50 60 180 70(VERTICAL) 200 300 400 450 500 550 40 20 50 40 60 70 60 80 80 90 100 100 Output Derating VS Input Voltage Derating Curve DC OK Relay Contact O.V.P. CONTROL PFC CONTROL PWM & PFC FG U.V.P. CIRCUIT DETECTION O.L.P. O.C.P. I/P RECTIFIERS & EMI FILTER CIRCUIT PFC FILTER & RECTIFIERS SWITCHING POWER -V +V Block Diagram 3 2 1 5,6 3,4 1,2 AC/L1 AC/L2 FG Assignment Assignment 3 2 2.521 1 1BT 63 + 1 2 3 4 5 6 2BT +V ADJ. Mechanical Specification 113. 5 Mechanical Specification TB2 1 2 3 4 5 6 113. 5 + 3 2 TB1 1 125.2 +V ADJ. 63 1 2 3 Assignment FG AC/L2 AC/L1 Assignment 1,2 3,4 5,6 Block Diagram I/P EMI FILTER & RECTIFIERS RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.C.P. U.V.P. O.L.P. FG DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. DC OK Relay Contact Output Derating VS Input Voltage Derating Curve 100 100 90 80 80 60 70 60 40 50 20 40 -30 0 10 20 30 40 50 60 70(VERTICAL) 180 200 300 400 450 500 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 79 PSW-480 Series Specifications SAVER ENERGY ENERGY SAVER OUTPUT OUTPUT Features: • Single and two phase wide input range 180~550VAC • High efficiency 93% and low power dissipation • Protections: Short Circuit / Overload / Over Voltage / Overtemperature • Cooling by free air convection • DIN rail mountable • UL 508(industrial control equipment) approved • EN61000-6-2 (EN50082-2) industrial immunity level • Built-in DC OK relay contact • 100% full load burn-in test • 3 year warranty Cat. No. PSW-48024 PSW-48048 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24V 20A 0 ~ 20A 480W 100mVp-p 48V 10A 0 ~ 10A 480W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 24 ~ 28V ±1.0% 48 ~ 55V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT INPUT LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE ±0.5% ±1.0% 800ms, 150ms, 18ms / 400VAC 180 ~ 550VAC ±0.5% ±1.0% 2000ms, 150ms, 16ms / 230VAC at full load 254 ~ 780VDC Derating may be needed under low input voltage. Please check the derating curve for more details PROTECTION PROTECTION FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD 47 ~ 63Hz 92% 1.6A / 400VAC COLD START 50A ≤ 3.5 mA / 530VAC 93% 4A / 230VAC 105 ~ 130% rated output power Protection type: Constant current limiting, unit will shut down after 3 sec.; auto recovery after 1 minute if the fault condition is removed OVERVOLTAGE 29 ~ 33V 56 ~ 65V Protection type: Shut down overvoltage; auto recovery after 1 minute if the fault condition is removed Under over-voltage condition, If input voltage ≤ 200VAC, the power supply will shut down and then may have auto-recovery after several seconds. OVERTEMPERATURE 95˚C ± 5˚C (TSW) detect on heat sink of power switch Protection type: Shut down overvoltage, recovers automatically after temperature goes down ENVIRONMENT ENVIRONMENT DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. -30 ~ +70˚C (Refer to output load derating curve) Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. SAFETY & EMC SAFETY & EMC WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING 20 ~ 95% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL508 approved IEC 60950-1 compliant Design refer to GL I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25˚C; 70% RH) EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN 55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A approved; WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. OTHERS OTHERS MTBF DIMENSION PACKING 112.8K hrs min. MIL-HDBK-217K (25˚C) 85.5x125.2x128.5mm (WxHxD) 1.7Kg; 8pcs / 14.6Kg / 0.9CUFT All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25˚C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 80 -30 0 10 20 30 40 50 60 70 180 (VERTICAL) 200 300 400 450 500 550 40 20 50 40 60 70 60 80 80 90 100 100 Output Derating VS Input Voltage Derating Curve DC OK Relay Contact O.V.P. CONTROL PFC CONTROL PWM & PFC CIRCUIT DETECTION FG U.V.P. O.L.P. O.C.P. I/P RECTIFIERS & EMI FILTER CIRCUIT PFC FILTER & RECTIFIERS SWITCHING POWER -V +V Block Diagram 3 2 1 AC/L1 AC/L2 FG Assignment 5,6 3,4 1,2 Assignment 3 2 1 1BT 85.5 1 2 3 4 5 6 2BT 2.521 + +V ADJ Mechanical Specification 128.5 Mechanical Specification 125.2 TB2 1 2 3 4 5 6 128.5 3 2 TB1 1 + +V ADJ 85.5 1 2 3 Assignment Assignment FG AC/L2 AC/L1 1,2 3,4 5,6 Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.C.P. U.V.P. O.L.P. DETECTION CIRCUIT FG PWM & PFC CONTROL PFC CONTROL O.V.P. DC OK Relay Contact Output Derating VS Input Voltage Derating Curve 100 100 90 80 80 60 70 60 40 50 20 40 -30 0 10 20 30 40 50 60 70 (VERTICAL) 180 200 300 400 450 500 550 Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 81 Accessories Power Supply Redundancy Buffer Module PS-RDN20 is a 20A redundancy (decoupling) module for the 24V DC power system. Containing 2 sets of 20A Or-ing diodes with wonderful heat dissipation deployment, PS-RDN20 give you a new option for safe connection of 1+1 redundant set-up. Not only perfectly decouple power sources from each other as well as from the load, PS-RDN20 also provides users monitoring signals for both input channels through the built-in relays. Since there’s no switching components inside the module, PS-RDN20 will not arise additional EMI issues and should provide you a worry-free application platform! DC input voltage range Reverse voltage DC output current DC output voltage drop Input voltage alarm Relay contact rating Working Temperature EMC standards Connection 21~28V, 20A max. x 2 channels 30V 20A max. 0.5V max. When input is > 20V(±5%) or <30V(±5%), relay contacts 30VDC, 1A -20~+70°C EN55022 class B, EN61000-4-2,3,4,5,6,8, ENV50204 I/P: 4 poles, O/P: 2 poles screw DIN terminal, Single output: 4 poles UPS Battery Module PS-UPS40 is a 40A max. DC UPS (battery control) module for the 24 V DC power system. Accompany with external batteries, it can back-up up to 40A of current to critical loads for certain period of time depending on the capacity of batteries. With complete monitoring signals and LED indicators for DC BUS OK, Battery Fail, Battery Discharge and the repeated Battery Test function to check the situation of external batteries. Users can customize their own DC UPS system to back up critical loads and capture the status of the whole system easily. DC input / DC bus Battery inout voltage Battery input current Charge current (typ.) External battery (typ.) DC bus ok Battery fail Battery discharge Working temperature EMC standards Connection 82 24~29V, 40A max. 21~29V 0~40A 2A 24V, 4AH / 7AH / 12AH Relay status: Short when DC voltage between 21~29V(±3%), relay contacts Relay status: Short when battery failure is observed through the battery test function, relay contacts LED (red): Battery over-discharge warning or battery broken: light; battery OK: dark Relay status: Short when battery in discharge condition, relay contacts LED (yellow): Battery discharging: light; battery is not discharging or discharging current <2A: dark -20~+70°C EN55022 class B, EN61000-4-2,3,4,5,6,8, ENV50204 I/P: 2 poles, O/P: 2 poles screw DIN terminal, Single output: 6 poles For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Redundancy Buffer Module UPS Battery Module Redundancy Buffer Module Features: • Suitable for redundant operation of 24V system • Installed on 35 x 7.5 mm or 35 x 15 mm DIN Rail • Relay contact signal output and LED indicator for input failure alarm • Cooling by free air convection • 3 year warranty UPS Battery Module Features: • Battery controller for DIN Rail UPS system • Installed on 35 x 7.5 mm or 35 x 15 mm DIN Rail • Parallel connection to DC BUS • Suitable for 24V system up to 40A • Built-in battery test function • Battery polarity protection • Relay contact signal output and LED indicator for DC BUS OK, battery fail and battery discharge • Cooling by free air convection • 3 year warranty 35mm DIN Rail mounting Alarm A and B Relay Contact LED indicator for input failure alarm (or DC BUS OK) Easy to understand layout panel CE Compliance Input Terminals Rugged metal housing Narrow for maximized panel space Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 83 Accessories • REDUNDANCY BUFFER MODULE • UPS MODULE Power Supply Redundancy Buffer Module PS-RDN20 is a 20A redundancy (decoupling) module for the 24V DC power system. Containing 2 sets of 20A Oring diodes with excellent heat dissipation deployment. PSRDN20 give you a new option for safe connection of 1+1 redundant set-up. Not only perfectly decouple power sources from each other as well as from the load, PS-RDN20 also provides users monitoring signals for both input channels through the built-in relays. Since there’s no switching components inside the module, PS-RDN20 will not arise additional EMI issues and should provide you a worry-free application platform! Cat. No. Voltage Range Current Range PS-RDN20 21-28V DC 0-20A NOTES Connection: Terminal 1 - 4 poles, Terminal 2 - 6 poles Size (WxHxD): 55.5x125x100mm (2.19x4.95x3.95 inches) Packaging: 1/box; 1.1lbs / 0.5Kg DC Fail Block Diagram 40 AMP UPS Battery Controller PS-UPS40 is a 40A max. DC UPS (battery control) module for the 24 V DC power system. Accompany with external batteries, it can back-up up to 40A of current to critical loads for certain period of time depending on the capacity of batteries. With complete monitoring signals and LED indicators for DC BUS OK, Battery Fail, Battery Discharge and the repeated Battery Test function to check the situation of external batteries. Users can customize their own DC UPS system to back up critical loads and capture the status of the whole system easily. Cat. No. Voltage Range PS-UPS40 21-29V (Battery) 24-29V (DC) Current Range NOTES 0 - 40A Connection: Terminal 1 - 4 poles, Terminal 2 - 6 poles Size (WxHxD): 55.5x125x100mm (2.19x4.95x3.95 inches) Packaging: 1/box; 1.21lbs / 0.55Kg 84 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. SPECIFICATIONS 12 Terminal Pin. No Assign. (TB1) Assignment Vout+ 1 Vout2 Vin3,4 5 Vin A+ 6 5.2 Derating Curve 100 80 LOAD (%) PS-RDN20 Series Terminal Pin. No Assign. (TB2) 60 40 Assignment 10 0 1 2 3 4 5.5 5 20 Alarm A1 Alarm A2 -10 0 10 20 30 40 50 60 Applications: PS U PSU 70 (VERTICAL) AMBIENT TEMPERATURE (°C) PSU PS U PS U PS U PS U PSU .............. Vin A PS U PSU Vin A Vin A Vin A Vin A Vout Vout Vout Vout Vout Vout Load Load Load PS-UPS40 Series Terminal Pin. No Assign. (TB1) Assignment BATTERY INPUT + BATTERY INPUT - 1 2 3 4 100 80 LOAD (%) 12 Derating Curve Terminal Pin. No Assign. (TB2) 5.2 Assignment 10 0 1 2 3 4 5 6 .5 55 -10 0 10 20 30 40 50 60 70 (VERTICAL) AMBIENT TEMPERATURE (°C) 2. Combine redundancy module (PS-RDN20) to back up AC interruption or failure of PSU PS-UPS40 PS-UPS40 PSU 24V/40Amax BAT + - 40 20 1. Backup connection for AC interruption 24V Battery 60 Load PS-RDN20 24V Battery DC - + PSU BAT DC - - + + Vout Load Vin + - - - B+ A+ - + + - + - - + + - - + Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 85 PS-RDN20 Features: Specifications OUTPUT • Suitable for redundant operation of 24V system • Installed on DIN Rail TS35 / 7.5 or 15 • Relay contact signal output and LED indicator for input failure alarm • Cooling by free air convection • 3 year warranty Cat. No. PS-RDN20 REVERSE VOLTAGE (max.) OUTPUT CURRENT (max.) VOLTAGE DROP LED INDICATORS 30V 20A 0.5V Two green LED’s indicating each input is OK or fail INPUT VOLTAGE RANGE NUMBER OF INPUTS INPUT CURRENT (max.) 21 ~ 28V Two 20A per input INPUT VOLTAGE ALARM RELAY CONTACT RATING (max.) When input is ≥ 20V (±5%) or ≤ 30V (±5%) relay contacts 30VDC, 1A WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION MOUNTING -20 ~ +70˚C 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY Terminal- Chassis: 0.5KVAC, Relay Contacts- Terminal: 0.5KVAC Terminal- Chassis: ≥100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-4-2,3,4,5,6,8; ENV50204; heavy industry level; criteria A, MTBF DIMENSION PACKING 996.8Khrs min. MIL-HDBK-217K (25˚C) 55.5x125.2x100mm (WxHxD) 0.5Kg; 20pcs / 11Kg / 1.29CUFT INPUT FUNCTION ENVIRONMENT SAFETY & EMC OTHERS All parameters NOT specially mentioned are measured at 24V DC input, rated load and 25˚C of ambient temperature. 86 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification TB2 1 2 3 4 5 6 TB1 125.2 LED 1 2 3 4 100 55. 5 Terminal Pin. No Assignment (TB1) Pin No. Assignment Vout+ 1 Vout2 Vin3,4 5 Vin B+ Vin A+ 6 Terminal Pin. No Assignment (TB2) Pin No. Assignment Alarm B1 1 Alarm B2 2 Alarm A1 3 Alarm A2 4 Block Diagram Vout+ + RELAY B Vin/Vout- + RELAY A Alarm A Vin A+ Derating Curve 100 80 60 40 20 -20 0 10 20 30 45 50 60 70 (VERTICAL) Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 87 PS-UPS40 Specifications DC INPUT / DC BUS BATTERY IN / OUTPUT FUNCTION Features: • Battery controller for DIN Rail UPS system • Parallel connection to DC BUS • Suitable for 24V system up to 40A • Installed on DIN Rail TS35/ 7.5 or 15 • Built-in battery test function • Battery polarity protection • Relay contact signal output and LED indicator for DC BUS OK, • Battery fail, and battery discharge • Cooling by free air convection • 3 year warranty Cat. No. PS-UPS40 DC VOLTAGE (Typ.) RATED CURRENT 24 ~ 29V 40A VOLTAGE RANGE (Typ.) CURRENT RANGE CHARGE CURRENT (Typ.) EXTERNAL BATTERY (Typ.) 21 ~ 29V 0 ~ 40A 2A 4 / 7 / 12AH / 24V RELAY CONTACT RATING (max.) DC BUS OK 30VDC, 1A Relay contact: Short when DC voltage between 21 ~ 29V (±3%), relay contacts LED (Green): DC BUS OK: light; DC BUS fail: dark Relay contact: Short when battery failure is observed through the battery test function, relay contacts LED (Red): Battery over- discharge warning or battery broken: light; Battery OK: dark BATTERY FAIL Every 25 seconds, unit will send out test signal through Battery Fail relay contact and LED indicator once the battery is fail. ENVIRONMENT BATTERY DISCHARGE Relay contact: Short when battery in discharge condition, relay contacts LED (Yellow): Battery discharging: light; Battery is not discharging or discharging current ≤2.0A: dark WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION MOUNTING -20 ~ +70˚C 20 ~ 90% RH -20 ~ +85˚C, 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY Terminal- Chassis: 0.5KVAC, Relay Contacts- Terminal: 0.5KVAC Terminal- Chassis: ≥100M Ohms / 500VDC (25˚C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-4-2,3,4,5,6,8; ENV50204; heavy industry level; criteria A MTBF DIMENSION PACKING 161.9Khrs min. MIL-HDBK-217K (25˚C) 55.5x125.2x100mm (WxHxD) 0.55Kg; 20pcs / 12Kg / 1.29CUFT SAFETY & EMC OTHERS All parameters NOT specially mentioned are measured at rated load and 25˚C of ambient temperature. 88 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Mechanical Specification 100 4 3 2 1 TB1 125.2 LED TB2 1 2 3 4 5 6 55. 5 Terminal Pin. No Assignment (TB1) Pin No. Assignment BATTERY INPUT + 1 BATTERY INPUT 2 3 DC INPUT 4 DC INPUT + Terminal Pin. No Assignment (TB2) Pin No. Assignment BAT DISC 1 1 BAT DISC 2 2 BAT OK 1 3 BAT OK 2 4 DC OK 1 5 DC OK 2 6 Block Diagram 25Ax2 LOAD + + BAT. TEST CHARGE CIRCUIT LIMIT INPUT POWER SUPPLY 24V BATTERY DETECTION CIRCUIT DISCHARGE Derating Curve 100 80 60 40 20 -20 0 10 20 30 45 50 60 70 (VERTICAL) Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 89 Accessories POWER SUPPLIES DIN MOUNTING RAILS Altech DIN Rails comply with DIN 50045, 50022 and 50035 Standards. The use of DIN Rails enhances design capabilities, saves space and reduces labor. Standard rails are made of steel with zinc plating and chromate passivation and are available in various configurations. DIN Rails are 35mm wide and available in 7.5 and 15mm depths. They are supplied in 1 m (3'3") and 2 m (6’6) lengths. Upon request they can be cut to custom lengths and punched with holes or perforations. DIN35 DIN35 (15 mm deep) (7.5 mm deep) Type Cat. No. Perforated Steel 2511120 2511120/1M 2m 1m Unperforated Steel 2511110 2511110/1M 2m 1m Type Cat. No. 20 40 Perforated Steel CA701-15/S-2M CA701-15/S 2m 1m 12 24 20 40 Unperforated Steel CA701-15-2M CA701-15 2m 1m 12 24 Length Std. Pk. Length Std. Pk. SUPPORT BRACKETS Support Brackets elevate DIN Rails away from the panel to facilitate component mounting and to increase wiring access. Angled brackets tilt the rail by 45° to improve visibility. Straight brackets are available in three heights for optimum positioning of the rail. Brackets mount with 2 screws to any panel or flat surface and have tapped center holes for rail mounting. Bracket material is steel, zinc plated yellow chromate. DIN35 DIN35 Cat. No. CA603 90 Std. Pk. 25 Height Cat. No. Std. Pk. 1 2 3 CA703 CA803 CA903 25 25 25 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. END STOPS and SPACER End Stops prevent power supplies and other DIN Rail mount components and devices from moving laterally on the rail. They are available in polyamide 6.6 and metal configurations for 35mm DIN rails. CA802 is a small endstop for the smaller power supplies. CA202 is a large endstop for larger power supplies. CA202 CA802 CA302 is used with 7.5mm deep DIN rail and the CA402 is used with 15mm deep rail. DIN Rail mountable spacers (CASP and 15.960) are generally used to ensure cooling space for the small power supply. CA302 CASP CA402 15.960 Polyamide 6.6 Polyamide 6.6 Steel Steel Polyamide 6.6 Polyamide 6.6 44.5 x 50 x 9.5 mm 32 x 45 x 8 mm 27 x 39.5 x 16 mm 27 x 39.5 x 16 mm 29 x 43 x 8 mm 69 x 55 x 9 mm Cat. No. CA202 Cat. No. CA802 Cat. No. CA302 Cat. No. CA402 Cat. No. CASP Std. Pk. 50 Std. Pk. 50 Std. Pk. 50 Std. Pk. 50 Std. Pk. 50 Cat. No. 15.960 Std. Pk. 10 GROUND BLOCKS for DIN Rail Use ground blocks instead of grounding studs and wire lugs to terminate ground wires, saving installation and wiring time. Ground blocks clamp mechanically onto the DIN Rail by tightening the center mounting screw, making a reliable electrical connection between the cage clamp terminals and the DIN Rail. The rail serves as a busbar and automatically distributes ground potential to all other ground terminals on the same rail. Ground blocks can also be used as end stops, preventing other terminal blocks and components from moving laterally on the DIN Rail. CGT4N CGT6N CGT10U They are supplied with a standard green/yellow housing for easy identification. AEx eII EEx eII Terminal Width 6 mm 8 mm 10 mm Height x Length 45.4 x 54.2 mm 47 x 54.5 mm 49.5 x 45 mm Stripping Length 9 mm 12 mm 12 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 2 screw clamps 2 screw clamps Approvals C US C US Wire Range 22-10 AWG 0.5-4 sq.mm 22-10 AWG 22-8 AWG Torque 7 lb-in 14 lb-in 0.8 Nm 7 lb-in C 1.5-6 sq.mm 22-8 AWG 0.8 Nm 14 lb-in US 22-6 AWG 1.5-10 sq.mm 16-8 AWG 14 lb-in 1.2 Nm Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 14 lb-in 91 Frequently Asked Questions Notes on choosing a switching power supply? • To increase the reliability of the switching power supply, we suggest users choose a unit that has a rating of 30% more power than actual need. For example, if the system needs a 90W source, we suggest that users choose a switching power supply with 120W of output power or more. By doing this, you can effectively boost the reliability of the switching power supply in your system. • We also need to consider about ambient temperature of the switching power supply and whether there is additional device for dissipating the heat. If the switching power supply is working in a high temperature environment, we need to make some derating to the output power. The derating curve of "ambient temperature" versus "output power" can be found on our spec sheets. • Choosing functions based on your application: • Protection function: • Overvoltage Protection (OVP) • Overtemperature Protection (OTP) • Overload Protection (OLP) • Short Circuit Protection (SCP) • Application function: • Signaling Function (Power Good, Power Fail) • DC OK Signal • Special function: • Power Factor Correction (PFC) • Uninterruptible Power Supply (UPS) function • Pick Load Capability • Make sure that the model qualifies for the safety standards and EMC regulations you need. How do we choose a power supply to charge a battery? ALTECH does not have power supplies designed for battery charging. If you like to choose a Power Supply as a battery charger, our advice is to pick a power supply with over load protection (OLP) which mode is constant current limiting. The models in this mode provide constant current even when the protection circuit is triggered. The second choice is fold-back current limiting or constant wattage model. In this model, when a battery is running low, the output current of the power supply will gently increase. The level of increase depends on battery's capacity and degree of exhaustion. Hiccup or shut down model are not recommended because it will stop to generate current when OLP happens. Does Altech carry class 2 power supplies? Selected models of the Altech slim line series (PS-S…) is NEC class 2 / LPS compliant, but they are not UL1310 tested. More information can be found on the individual specification sheets. Can ALTECH's power supply be used in the range of 45Hz ~ 440Hz? If YES, what will happen? ALTECH's power supply can be used within this frequency range. But if the frequency is too low, the efficiency will also be lower. For example, when a PS-12024 is operated under 230VAC and rated load, if the frequency of AC input is 60 Hz, the efficiency is around 84%; however, if the frequency of AC input reduces to 50 Hz, the efficiency will be around 83.8%. If the frequency is too high, the power factor of the switching power supply with PFC (power factor correction) function will reduce and this also will cause higher leakage current. For example, when a PS12024 is operated under 230VAC and rated load, if the frequency of AC input is 60 Hz, the power factor is 0.93 and the leakage current is around 0.7mA; however, if the frequency of AC input increase to 440 Hz, the power factor will decrease to 0.75 and the leakage current will rise to around 4.3mA. If we need a 24V output power supply, but ALTECH does not have this model, can we use two 12V power supplies connecting in series instead of one 24V power supply? YES, basically you can do this to get the right output voltage, but be careful that the rated output current of the series system should be the rating of the minimum one in these series connected power supplies. Furthermore, we like you to parallel a diode at the output of power supply to prevent possible damage of internal capacitors. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 92 Why I cannot turn on the power supply smoothly when the loads are motors, light bulbs or capacitive loads? If you connect the switching power supply to motors, light bulbs, or high capacitive loads, you will have a high output surge current when you turn on the S.P.S. and this high surge current will cause failure of start up. We suggest using switching power supply with over load protection and constant current limiting protection to deal with these loads. Why did the power supply shuts down during operation and after turning it off, I can restart the power supply again? In general there are two circumstances that will cause the power supply to shut down. The first one is the activation of the over-load-protection (OLP). To deal with this situation, we suggest increasing the rating of the output power or modifying the OLP point. The second one is the activation of over-temperature protection (OTP) when the internal temperature reaches the pre-set value. All of these conditions will let the switching power supply enter protection mode and shut down. After these conditions are removed, the switching power supply will be back to normal. The output ground (GND) and frame ground (FG) is the same point in my system, can ALTECH's power supplies be used in such system? Yes. Since our products are designed based on isolation concept, it will be no problem that the output ground (GND) and frame ground (FG) is the same point in your system. But, EMI may be affect by this connection. During the operation of ALTECH power supply, there is some leakage current on the case. Is this normal? Will this leakage current hurt human body? Due to the requirement of EMI, there will be some Y capacitors between line and neutral to the FG (case) to improve EMC. These Y capacitors will cause some leakage current flow from line or neutral to the case (normally case will be connected to earth ground). For example, IEC-60950-1 requires that this current should be less than 3.5mA for IT equipment, so basically the leakage current you find on the case will not hurt human body. Proper connection to Earth ground will solve the leakage current problem. What should be noticed when installing a power supply in vertical and horizontal directions? Most small wattage power supplies are mainly installed in the horizontal position. If you have to install it vertically because of mechanical limitation, you should consider the output derating due to the heat concern. The temperature derating curve can be found on the spec sheet. What is "Input - Inrush Current"? What will we notice? At input side, there will be (1/2 ~1 cycle, ex. 1/120 ~ 1/60 seconds for 60 Hz AC source) large pulse current (20~60A based on the design of S.P.S.) at the moment of power on and then back to normal rating. This "Inrush Current" will appear every time you turn on the power. Although it will not damage the power supply, we suggest not turning the power supply ON/OFF very quickly within a short time. Besides, if there are several power supplies turning on at the same time, the circuit breaker of AC source may shut off and go into protection mode because of the huge inrush current. It is suggested that these power supplies start up one by one if possible. What is PFC? PFC stands for Power Factor Correction. The purpose of PFC is to improve the ratio of apparent power and real power. The power factor is only 0.4~0.6 in non-PFC models. In PFC models, the power factor can reach above 0.95. The calculation formulas are as below: Apparent Power=Input Voltage x Input Current (VA) Real Power= Input Voltage x Input Current x Power Factor (W) From the environment friendly point, the electric power plant needs to generate a power which is higher than apparent power in order to steadily provide electricity to the market. The real usage of electricity should be defined by real power. Assuming the power factor is 0.5, the power plant needs to produce more than 2VA to satisfy 1W real power. On the contrary, if the power factor is 0.95, the power plant only needs to generate more than 1.06VA to provide 1W real power need. It will be more effective. What is the difference between -V, +V and COM which are marked on the output side? COM(COMMON) means common ground. Single output: Positive pole (+V), Negative pole (-V) +V; COM and –V can be attained by using two switching power supplies in series. Example: (2x PS-S2012) + – + – In ALTECH's catalog, we see AC and DC at input, what is it all about? Due to different circuit designs, ALTECH power supply's input consists of three types as below: (√2=1,414 → 1.414 x AC = DC) +12V COM -12V A.85~264VAC;120~370VDC B.176~264VAC;250~370VDC C.85~132VAC/176~264VAC by Switch; 250~370VDC • In the case of option A and B inputs models, power supply can work properly no matter under AC or DC input. Some models need correct connection of input poles, positive pole connects to AC/L; negative pole connects to AC/N. Others may require opposite connection, positive pole to AC/N; negative pole to AC/L. If customers make a wrong connection, the power supply will not be broken. You can just reverse the input poles and power supply will still work. • In the case of option C input models, please make sure that you switch the 115/230V input correctly. If the switch is on the 115V side and the real input is 230V, the power supply will be damaged. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 93 Frequently Asked Questions Why the input voltage marked on the spec. sheet is 88~264 VAC while the label on the power supply says that it is 100~240VAC? During safety verification process, the agency will use a stricter standard -- ±10%(IEC60950 uses +6%, -10%) of the input voltage range labeled on the power supply to conduct the test. So, operating at the wider input voltage range as specified on the spec. sheet should be fine. The narrower range of input voltage labeled on the power supply is to fulfill the test standard of safety regulation and make sure that users insert input voltage correctly. Will ALTECH’s products with CE marking meet the EMC requirements after assembling into my system? We cannot guarantee 100% that the final system can still meet the EMC requirements. The location, wiring and grounding of the switching power supply in the system may influence its EMC characteristics. In different environment or applications, the same switching power supply may have different outcomes. Our test results are based on setup shown in the EMC report. What is different between information (EN60950-1) and medical (EN60601-1) safety standard? According to safety standard, the leakage current in EN60950-1 Class I cannot exceed 3.5mA. Many of ALTECH’s power supplies meet this requirement but may not meet the EN60601-1. Others criteria like safe distance and numbers of fuse are also different. Please consult the diagram below: Subjects Creepage distance/ Clearance distance Working Voltage: Max. 250Vrms Electric Strength Test IEC60950-1 IEC60601-1 Basic Insulation 2.5mm/2mm 4mm/2.5mm Supplementary Insulation 5mm/4mm 8mm/5mm Basic Insulation 1500Vac 1500Vac Supplementary Insulation 3000Vac 4000Vac Handheld: 0.75mA — Leakage current of grounding 0.3mA Leakage current of grounding 0.1mA 0.25mA Leakage current of grounding 0.1mA Number of Fuse 1 2 The Lowest Ambient Temperature Refer to the definition of Manufacturer 40°C CLASS I Leakage Current CLASS II Others: 3.5mA What is MTBF? Is it different from Life Cycle? MTBF and Life Cycle are both indicators of reliability. Altech uses MIL-HDBK-217F as the core of MTBF. An expected reliability is forecasted through accounting component's number. The exact meaning of MTBF is after continuously using of power supply in a certain time, the probability of operating properly is 36.8%(e-1=0.368). If power supply is continuously used at double the MTBF time, the probability of operating properly becomes 13.5%(e-2=0.135). Life Cycle is found through using the temperature rise of electrolytic capacitor to estimate the approximate life of power supply. For example, PS-S10 series MTBF=584K hours; electrolytic capacitor C108 Life Cycle=202K hours (Ta=45° C). POWER SUPPLY LEGAL DISCLAIMER Power supply data sheet specifies devices but can not promise to deliver any specific characteristics. No warranty or guaranty is given regarding performance or suitability. The customer shall test and ensure that each power supply would work for the anticipated use. Altech Corp. reserves the right to make modification to its power supply data sheets or specifications at any time without prior notice. Please visit www.altechcorp.com/power for more information. 94 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Selection Guide SIG = DC OK signal X* = selected items, see data sheet X X PS-C480Pxx X PS-C480xx X PS-C240xx X PS-C120xx X X PST-960Pxx X PST-960xx X PST-480xx X PST-240xx X PSP-480Sxx X PSP-480xx X PSP-240xx X PSH-120xx X PS-120xx X PS-75xx X X PS-100xx PS-60xx X X X X X X X X X X X X X X X X X X X X 5 X WR X WR X WR X X X X X X X X X X X X 15 24 X X X X X X X X X X DBO X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X V X X X X X X X X X X X X X X X X X X X X X X X X X X X X 48 X X X TP TP X X X X X TP TP X X X X X X X X X X X X X X X 12 Output voltage X X X X X* X X X* X X X* X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SIG X X X X X X X X X X X SIG X X X X X Output voltage U ni ve r Sw sal itc Inp u h U Se t L 50 lec U 8 L t In L 60 iste put d N 950 EC -1 C Cla Rec E . m ss ar 2 C R k oh ed om s pl R Co ia ea nt m ch p l i D a C Co nt m O pl Sh K ia nt or t O Cir ve c rlo uit a O ve d r O Vol ve ta ge r EM Tem pe C ra C tu B re X PSW-120xx PS-45xx PS-30xx PS-15xx PS-S20xx PS-S10xx nU vi re as S Il iw pn ct h tu S LU le ce 05 It L8 U L pn si tu det 06 9 N 05 1- CE e R lC C .c sa E s 2 ram oC ek oR m d sh oC eR m a lp hc ai C D C tn o m O lp K S ai oh tn tr iC O cr ev tiu olr da vO re V lo O at rev eg T e E m M ep C ar C B ut er X PSW-240xx PS-S100xx PS-S60xx PS-S40xx DBO = DC bus OK V = 220V INPUT ONLY 21-28 21-28 PSW-480xx lp ai tn WR = wide range input TP = three phase input PS-UPS PS-RDN 5 12 15 24 48 PS-S10xx X X X X X X X X X X SIG X X X X X PS-S20xx X X X X X X X X X X SIG X X X X X PS-S40xx X X X X X X X X* X X X X X X X X X PS-S60xx X X X X X X X X* X X X X X X X X X X X X X X X* X X X X X X X X X PS-S100xx X PS-15xx X X X X X X X X X X X X X X PS-30xx X X X X X X X X X X X X X X PS-45xx X X X X X X X X X X X X X PS-60xx X X X X X X X X X X X X X X PS-100xx X X X X X X X X X X X X X X PS-75xx X X X X X X X X X X X X PS-120xx X X X X X X X X X X X X X PSH-120xx X X X X X X X X X X X X X PSP-240xx X X X X X X X X X X X X X X PSP-480xx X X V X X X X X X X X X X X PSP-480Sxx X X X X X X X X X X X X X PST-240xx X X TP X X X X X X X X X X X PST-480xx X X TP X X X X X X X X X X X PST-960xx X X TP X X X X X X X X X X X PST-960Pxx X X TP X X X X X X X X X X X X X X X X X X X X X X X X X PS-C240xx X X X X X X X X X X X X X X PS-C480xx X X X X X X X X X X X X X X PS-C480Pxx X X X X X X X X X X X X X X X X WR X X X X X X X X X X X PSW-240xx X X WR X X X X X X X X X X X PSW-480xx X X WR X X X X X X X X X X X PS-C120xx PSW-120xx X X X X X X X X X PS-RDN 21-28 X X X X PS-UPS 21-28 X X X DBO X TP = three phase input WR = wide range input X* = selected items, see data sheet SIG = DC OK signal V = 220V INPUT ONLY DBO = DC bus OK Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 95 Index Part No. Page PS-10012 .........................................22, PS-10015 .........................................22, PS-10024 .........................................22, PS-12012 .........................................36, PS-12024 .........................................36, PS-12048 .........................................36, PS-1505 ...........................................22, PS-1512 ...........................................22, PS-1515 ...........................................22, PS-1524 ...........................................22, PS-3005 ...........................................22, PS-3012 ...........................................22, PS-3015 ...........................................22, PS-3024 ...........................................22, PS-4505 ...........................................22, PS-4512 ...........................................22, PS-4515 ...........................................22, PS-4524 ...........................................22, PS-6005 ...........................................22, PS-6012 ...........................................22, PS-6015 ...........................................22, PS-6024 ...........................................22, PS-7512 ...........................................36, PS-7524 ...........................................36, PS-7548 ...........................................36, PS-C12012 ......................................62, PS-C12024 ......................................62, PS-C12048 ......................................62, PS-C24024 ......................................62, PS-C24048 ......................................62, PS-C48024 ......................................62, PS-C48048 ......................................62, PS-C480P24 ....................................62, PS-C480P48 ....................................62, PS-RDN20 .......................................84, PS-S10012.........................................8, PS-S10024.........................................8, PS-S10048.........................................8, PS-S1005...........................................8, PS-S1012...........................................8, PS-S1015...........................................8, PS-S1024...........................................8, PS-S2005...........................................8, PS-S2012...........................................8, PS-S2015...........................................8, PS-S2024...........................................8, PS-S4005...........................................8, PS-S4012...........................................8, PS-S4024...........................................8, PS-S4048...........................................8, 96 Part No. 32 32 32 40 40 40 24 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 38 38 38 64 64 64 66 66 68 68 70 70 86 18 18 18 10 10 10 10 12 12 12 12 14 14 14 14 Page PS-S6005...........................................8, 16 PS-S6012...........................................8, 16 PS-S6024...........................................8, 16 PS-S6048...........................................8, 16 PS-UPS40........................................84, 88 PSH-12024 ......................................36, 42 PSH-12048 ......................................36, 42 PSP-24024.......................................36, 44 PSP-24048.......................................36, 44 PSP-48024.......................................46, 48 PSP-48048.......................................46, 48 PSP-480S24 ....................................46, 50 PSP-480S48 ....................................46, 50 PST-24024 .......................................52, 54 PST-24048 .......................................52, 54 PST-48024 .......................................52, 56 PST-48048 .......................................52, 56 PST-96024 .......................................52, 58 PST-96048 .......................................52, 58 PST-960P24 .....................................52, 58 PST-960P48 .....................................52, 58 PSW-12012......................................74, 76 PSW-12024......................................74, 76 PSW-12048......................................74, 76 PSW-24024......................................74, 78 PSW-24048......................................74, 78 PSW-48024......................................74, 80 PSW-48048......................................74, 80 Accessories: 15.960 ....................................................91 2511110 .................................................90 2511110/1M...........................................90 2511120 .................................................90 2511120/1M...........................................90 CA202 ....................................................91 CA302 ....................................................91 CA402 ....................................................91 CA603 ....................................................90 CA701-15...............................................90 CA701-15-2M ........................................90 CA701-15/S ...........................................90 CA701-15/S-2M.....................................90 CA703 ....................................................90 CA802 ....................................................91 CA803 ....................................................90 CA903 ....................................................90 CASP .....................................................91 CGT10U .................................................91 CGT4N ...................................................91 CGT6N ...................................................91 For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 97