Evaluation Kit Manual

S6SBP501A00VA1001,
S6SBP502A00VA1001
Evaluation Kit for Automotive PMIC
Operation Manual
Publication Number S6SBP501A00VA1001_SS901-00044
CONFIDENTIAL
Revision 1.0
Issue Date September 25, 2015
v1.1
O P E R A T I O N
M A N U A L
Preface
This manual explains how to use the evaluation board. Be sure to read this manual before using the product.
For this product, please consult with sales representatives or support representatives.
Handling and Use
Handling and use of this product and notes regarding its safe use are described in the manuals.
Follow the instructions in the manuals to use this product.
Keep this manual at hand so that you can refer to it anytime during use of this product.
Notice on this Document
All information included in this document is current as of the date it is issued. Such information is subject to
change without any prior notice.
Please confirm the latest relevant information with the sales representatives.
2
CONFIDENTIAL
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
M A N U A L
Caution of the Products Described in this Document
The following precautions apply to the product described in this manual.
WARNING
Electric Shock,
Damage
Electric Shock,
Damage
Indicates a potentially hazardous situation which could result in death or serious injury and/or a
fault in the user’s system if the product is not used correctly.
Before performing any operation described in this manual, turn off all the power supplies to the
system.
Performing such an operation with the power on may cause an electric shock or device fault.
Once the product has been turned on, do not touch any metal part of it.
Doing so may cause an electric shock or device fault.
Indicates the presence of a hazard that may cause a minor or moderate injury, damages to this
CAUTION
product or devices connected to it, or may cause to loose software resources and other
properties such as data, if the device is not used appropriately.
Before moving the product, be sure to turn off all the power supplies and unplug the cables.
Cuts, Damage
Watch your step when carrying the product. Do not use the product in an unstable location such
as a place exposed to strong vibration or a sloping surface. Doing so may cause the product to
fall, resulting in an injury or fault.
Cuts
The product contains sharp edges that are left unavoidably exposed, such as jumper plugs.
Handle the product with due care not to get injured with such pointed parts.
Do not place anything on the product or expose the product to physical shocks. Do not carry the
Damage
product after the power has been turned on.
Doing so may cause a malfunction due to overloading or shock.
Since the product contains many electronic components, keep it away from direct sunlight, high
Damage
temperature, and high humidity to prevent condensation. Do not use or store the product where
it is exposed to much dust or a strong magnetic or electric field for an extended period of time.
Inappropriate operating or storage environments may cause a fault.
Damage
Use the product within the ranges given in the specifications.
Operation over the specified ranges may cause a fault.
To prevent electrostatic breakdown, do not let your finger or other object come into contact with
Damage
the metal parts of any of the connectors. Before handling the product, touch a metal object
(such as a door knob) to discharge any static electricity from your body.
When turning the power on or off, follow the relevant procedure as described in this document.
Damage
Before turning the power on, in particular, be sure to finish making all the required connections.
Furthermore, be sure to configure and use the product by following the instructions given in this
document. Using the product incorrectly or inappropriately may cause a fault.
Because the product has no casing, it is recommended that it be stored in the original
Damage
packaging. Transporting the product may cause a damage or fault. Therefore, keep the
packaging materials and use them when re-shipping the product.
September 11, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
3
V1.1
O P E R A T I O N
M A N U A L
Table of Contents
1. Description ............................................................................................................................................... 5
2. Evaluation Board Specification .............................................................................................................. 6
3. Pin Descriptions ...................................................................................................................................... 7
3.1 Input/Output Pin Descriptions ......................................................................................................... 7
3.2 Jumper Descriptions ....................................................................................................................... 8
4. Setup ......................................................................................................................................................... 9
4.1 Connecting ..................................................................................................................................... 9
4.2 Verification ...................................................................................................................................... 9
5. Layout ..................................................................................................................................................... 10
5.1 Component Layout ....................................................................................................................... 10
5.2 Wiring Layout ............................................................................................................................... 11
6. Circuit Schematic .................................................................................................................................. 12
7. Component List ..................................................................................................................................... 13
8. Ordering Information ............................................................................................................................. 15
9. Major Changes ....................................................................................................................................... 15
Figures
Figure 1-1 Board Outline ............................................................................................................................ 5
Figure 2-1 Evaluation Board Specification ................................................................................................. 6
Figure 3-1 Pin Layout ................................................................................................................................. 7
Figure 4-1 Connecting the Board and Some Equipment ............................................................................ 9
Figure 5-1 Evaluation Board Component Layout ..................................................................................... 10
Figure 5-2 Evaluation Board Wiring Layout ............................................................................................... 11
Figure 6-1 Evaluation Board Circuit Schematic ........................................................................................ 12
Tables
Table 3-1 Input/Output Pin Descriptions ..................................................................................................... 7
Table 3-2 Jumper Descriptions ................................................................................................................... 8
Table 7-1 Evaluation Board Component List ............................................................................................ 13
Table 8-1 Ordering Information ................................................................................................................. 15
Table 9-1 Major Changes ......................................................................................................................... 15
4
CONFIDENTIAL
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
S6SBP501A00VA1001,
S6SBP502A00VA1001
Evaluation Kit for Automotive PMIC
Operation Manual
1.
Description
S6SBP501A00VA1001 and S6SBP502A00VA1001 are the evaluation kit for power block of automotive
instrument cluster.
These boards implement power management IC S6BP501A, S6BP502A each.
It is necessary to prepare DC power supply.
Figure 1-1 Board Outline
S6SBP501A00VA1001
S6SBP502A00VA1001
VIN
VBATf
DC Power Supply
4.5V to 42V
π Type Filter
PGND1f
S6BP501A : PMIC
S6BP502A : PMIC
LDO
DC/DC Converter
A
DD3V
Buck +
SW
A
B
VOUT3Vf
PGND3Vf
B
VOUT5Vf
DD5V
Boost
PGND5Vf
VOUT3V
3.30V / 1.6A:
S6SBP501A00VA1001
3.30V / 1.9A:
S6SBP502A00VA1001
VOUT5V
5.00V / 1.3A
C
C
DD1V
Buck
VOUT1Vf
PGND1Vf
VIN
VOUT1V
1.11V / 1.4A:
S6SBP501A00VA1001
1.20V / 2.0A:
S6SBP502A00VA1001
EN5V
EN1V
EN3V
Logic /
SYNC
Power Good
ENSS
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
HOT
PG5V
PG3V
PG1V
5
V1.1
O P E R A T I O N
2.
M A N U A L
Evaluation Board Specification
Figure 2-1 Evaluation Board Specification
Item
Input Voltage
Output Voltage
S6SBP501A00VA1001
Output Current
Output Voltage
S6SBP502A00VA1001
Output Current
6
CONFIDENTIAL
Symbol
Min.
Typ.
Max.
Unit
VIN
4.5
12
42
V
VOUT3V
-
3.30
-
V
VOUT5V
-
5.00
-
V
VOUT1V
-
1.11
-
V
IOUT3V
-
-
1.6
A
IOUT5V
-
-
1.3
A
IOUT1V
-
-
1.4
A
VOUT3V
-
3.30
-
V
VOUT5V
-
5.00
-
V
VOUT1V
-
1.20
-
V
IOUT3V
-
-
1.9
A
IOUT5V
-
-
1.3
A
IOUT1V
-
-
2.0
A
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
3.
M A N U A L
Pin Descriptions
3.1
Input/Output Pin Descriptions
Table 3-1 Input/Output Pin Descriptions
Connecter Symbol
I/O
Function Description
VBATf
I
DC power supply terminal
VOUT3Vf
O
DD3V via load switch output terminal
VOUT5Vf
O
DD5V DC/DC convertor output terminal
VOUT1Vf
O
DD1V DC/DC convertor output terminal
-
Ground terminal
EN3V
I
VOUT3V: Load switch of DD3V enable terminal
EN5V
I
VOUT5V: DD3V and DD5V enable terminal
EN1V
I
VOUT1V: DD1V enable terminal
SYNC
I
PG3V
O
VOUT3V power good terminal
PG5V
O
VOUT5V power good terminal
PG1V
O
VOUT1V power good terminal
HOT
O
Thermal warning output terminal
PGNDf, PGND3Vf,
PGND5Vf, PGND1Vf
CN-EN
CN-PG
External clock input terminal.
Please use by referring to the data sheet of S6BP501A, S6BP502A.
Figure 3-1 Pin Layout
CN-EN
EN3V
EN5V
EN1V
SYNC
PG3V
PG5V
PG1V
HOT
CN-PG
VOUT3Vf
PGND3Vf
VOUT1Vf
PGND1Vf
PGND5Vf
VOUT5Vf
VBATf
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
PGNDf
7
V1.1
O P E R A T I O N
3.2
M A N U A L
Jumper Descriptions
Table 3-2 Jumper Descriptions
Jumper
Description
Initial Setting
Shorted VIN to EN5V or input external signal to EN5V.
R21
R21 Short and R22 Open: Shorted between VIN and EN5V.
Short
R21 Open and R22 Mounted resister: In the case of using external signal to
EN5V, shorted between GND and EN5V through resistor to prevent Hi-z
R22
status of EN5V.R22 is recommended 1MΩ.
No mount
Don’t input external signal to EN5V pin with shorted R21.
R23
Open
Shorted VB or GND to ENSS.
R23 Short: Shorted between VB and ENSS. SSCG function is on.
R24 Short: Shorted between GND and ENSS. SSCG function is off.
R24
8
CONFIDENTIAL
R23 and R24 must not be shorted simultaneously.
Short
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
4.
M A N U A L
Setup
4.1
Connecting
1. Connect the board to the power supply, load equipment and voltage meter as below.
Figure 4-1 Connecting the Board and Some Equipment
Voltage
Meter
+
Voltage
Meter
Load
+
+
-
Load
+
Voltage
Meter
+
-
Load
+
-
+12V Power
+ Supply
4.2
Verification
1.
2.
3.
4.
Turn on +12V power supply. VOUT5Vf will start output.
Connect EN3V to VOUT5Vf, then, VOUT3Vf will start output.
Connect EN1V to VOUT5Vf, then, VOUT1Vf will start output.
Check that each output voltage is the same as the 'Output Voltage' of Figure 2-1 Evaluation Board
Specification.
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
9
V1.1
O P E R A T I O N
5.
M A N U A L
Layout
5.1
Component Layout
Figure 5-1 Evaluation Board Component Layout
Layer1 Top View
Layer4 Top View
Board size: 65mm × 65mm
10
CONFIDENTIAL
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
5.2
M A N U A L
Wiring Layout
Figure 5-2 Evaluation Board Wiring Layout
layer 1 Top View
layer 2 Top View
layer 3 Top View
layer 4 Top View
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
11
V1.1
O P E R A T I O N
6.
M A N U A L
Circuit Schematic
Figure 6-1 Evaluation Board Circuit Schematic
VIN
FB1
VBATf
C10-2
C10-1
R25
L4
+
C12
PGNDf
VB
VIN
VB 22
17 VIN
C1
D1
VOUT5V
C2
VDD 13
C3
C13
A
BST3V 14
R2-1 R2-2
DRVH3V 15
LX3V 16
DRVL3V 12
21 FB3V
R3
C5-2 C5-1
R20
C4
A
Q1
C6-1 C6-3 C6-5 C6-7
Q2
PGND3V 11
L1
R17
C6-2 C6-4 C6-6
CSP 20
CSN 19
M1
IN3V 23
VOUT3V 24
C15
B
VOUT3Vf
C17
R6-1 R6-2
8
FB5V
VOUT5V 7
PGND3Vf
B
VOUT5V
C19-1 C-19-3 C19-5
PGND5Vf
R7
C11
C
LX5V 6
R10-1 R10-2
1
FB1V
EN1V
VB
R23 R21
2
C23-1 C23-2
C
L3
C24-1 C24-2 C24-3 C24-4
PGND1V 4
4
9
CN-EN
R24 R22
VOUT1Vf
PGND1Vf
VOUT5V
26 EN1V
25 SYNC
3
CONFIDENTIAL
C18-1 C18-2
27 EN3V
18 EN5V
1
12
LX1V 3
VIN
L2 C19-2 C19-4 C19-6
PGND5V 5
PVCC1V 2
R11
EN3V
VOUT5Vf
EN1V
EN3V
ENSS
R13 R14 R16 R15
CN-PG
10 GND1
29 GND2
PG3V 31
PG5V 32
1
EP
PG1V 30
HOT 28
3
2
4
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
7.
M A N U A L
Component List
Table 7-1 Evaluation Board Component List
Rated
Rated
Voltage(V)
Current(A)
0.1 µF
50
-
-
TDK
4.7 µF
16
-
-
CGA3E2X7R1H104K080AA
TDK
0.1 µF
50
-
-
CGA3E2X7R1H104K080AA
TDK
0.1 µF
50
-
-
CGA5L3X7R1H475K160AB
TDK
4.7 µF
50
-
-
C5-2
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
C6-1
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
8
C6-2
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
No.
Component
Parts Number
Vendor
Value
1
C1
CGA3E2X7R1H104K080AA
TDK
2
C2
CGA4J3X7R1C475K125AB
3
C3
4
C4
5
C5-1
6
7
Remarks
9
C6-3
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
10
C6-4
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
11
C6-5
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
12
C6-6
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
13
C6-7
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
14
C10-1
CGA5L3X7R1H475K160AB
TDK
4.7 µF
50
-
-
15
C10-2
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
16
C11
CGA3E2C0G1H120J080AA
TDK
12 pF
50
-
-
17
C12
-
-
-
-
-
NMT
18
C13
CGA3E2C0G1H100D080AA
TDK
10 pF
50
-
-
19
C15
-
-
-
-
-
NMT
20
C17
CGA3E2X7R1H104K080AA
TDK
0.1 µF
50
-
-
21
C18-1
CGA5L1X7R1C106K160AC
TDK
10 µF
16
-
-
22
C18-2
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
23
C19-1
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
24
C19-2
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
25
C19-3
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
26
C19-4
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
27
C19-5
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
28
C19-6
-
-
-
-
-
NMT
29
C23-1
CGA5L1X7R1C106K160AC
TDK
10 µF
16
-
-
30
C23-2
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
31
C24-1
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
32
C24-2
CGA6P1X7R1C226M250AC
TDK
22 µF
16
-
-
33
C24-3
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
34
C24-4
CGA2B3X7R1H104K050BB
TDK
0.1 µF
50
-
-
35
D1
RB521S30T1G
ON Semi
-
30
0.2
-
36
FB1
RK73Z2A
KOA
0Ω
-
2
-
37
L1
CLF12577NIT-4R7N-D
TDK
4.7 µH
-
9
-
38
L2
CLF6045NIT-1R5N-D
TDK
1.5 µH
-
4.5
-
39
L3
CLF6045NIT-1R5N-D
TDK
1.5 µH
-
4.5
-
40
L4
CLF7045T-4R7N
TDK
4.7 µH
-
3.6
41
M1
S6BP501A00SN2B000
S6BP502A00SN2B000
Cypress
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
-
-
-
S6SBP501A00VA1001
S6SBP502A00VA1001
13
V1.1
O P E R A T I O N
M A N U A L
Rated
Rated
Voltage(V)
Current(A)
-
60
7.6
-
-
60
7.6
-
KOA
200 kΩ
-
-
-
RK73H1JTTD1203F
KOA
120 kΩ
-
-
-
RK73H1JTTD1203F
KOA
120 kΩ
-
-
-
R6-1
RK73H1JTTD2004F
KOA
2 MΩ
-
-
-
48
R6-2
RK73H1JTTD1804F
KOA
1.8 MΩ
-
-
-
49
R7
RK73H1JTTD1204F
KOA
1.2 MΩ
-
-
-
-
S6SBP501A00VA1001
1
S6SBP502A00VA1001
No.
Component
Parts Number
Vendor
Value
42
Q1
NVTFS5826NL
ON Semi
43
Q2
NVTFS5826NL
ON Semi
44
R2-1
RK73H1JTTD2003F
45
R2-2
46
R3
47
50
R10-1
51
R10-2
RK73H1JTTD1002F
RK73Z1J
RK73H1JTTD2703F
RK73H1JTTD3303F
KOA
KOA
52
R11
53
R13
RK73H1JTTD1003F
KOA
54
R14
RK73H1JTTD1003F
55
R15
56
R16
57
R17
58
R20
59
0Ω
270 kΩ
330 kΩ
-
-
S6SBP501A00VA1001
-
-
100 kΩ
-
-
-
KOA
100 kΩ
-
-
-
RK73H1JTTD1003F
KOA
100 kΩ
-
-
-
RK73H1JTTD1003F
KOA
100 kΩ
-
-
-
ERJ-8BWFR012V
Pana
12 mΩ
KRL3216E-M-R010-F
SSM
10 mΩ
-
-
RK73Z1E
KOA
0Ω
-
1
-
R21
RK73Z1E
KOA
0Ω
-
1
-
60
R22
-
-
-
-
-
NMT
61
R23
-
-
-
-
-
NMT
62
R24
RK73Z1E
KOA
0Ω
-
1
-
63
R25
RK73Z2A
KOA
0Ω
-
2
-
RK73H1JTTD2703F
KOA
10 kΩ
Remarks
270 kΩ
TDK
:
TDK Corporation
ON Semi
:
ON Semiconductor
Cypress
:
Cypress Semiconductor Corp
KOA
:
KOA Corporation
Pana
:
Panasonic Corporation
:
SUSUMU CO., LTD.
SSM
S6SBP502A00VA1001
S6SBP501A00VA1001
S6SBP502A00VA1001
NMT: No mount.
These components are compliant with RoHS, and please ask each vendor for details if necessary.
14
CONFIDENTIAL
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
8.
M A N U A L
Ordering Information
Table 8-1 Ordering Information
Part Number
EVB Revision
Note
S6SBP501A00VA1001
S6SBP501A-VA1
Mounted IC: S6BP501A00SN2B000
S6SBP502A-VA1
S6SBP502A00VA1001
9.
Mounted IC: S6BP502A00SN2B000
Rev 1.0
Major Changes
Table 9-1 Major Changes
Page
Section
Change Results
Revision 1.0
-
-
Initial release
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
15
V1.1
O P E R A T I O N
16
CONFIDENTIAL
M A N U A L
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1
O P E R A T I O N
M A N U A L
SS901-00044-1v0-E
Cypress  Support Tool Manual
S6SBP501A00VA1001,
S6SBP502A00VA1001
Evaluation Kit for Automotive PMIC
Operation Manual
September 2015 Rev. 1.0
Published:
Edited:
Cypress Semiconductor Corp.
Communications
September 25, 2015, S6SBP501A00VA1001_SS901-00044-1v0-E
CONFIDENTIAL
17
V1.1
O P E R A T I O N
M A N U A L
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use,
including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not
designed, developed and manufactured as contemplated (1) for any use that includes fatal risks or dangers that, unless
extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury,
severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control,
mass transport control, medical life support system, missile launch control in weapon system), or (2) for any use where
chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Cypress will not be liable to
you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any
semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures
by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention
of over-current levels and other abnormal operating conditions. If any products described in this document represent goods
or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the
US Export Administration Regulations or the applicable laws of any other country, the prior authorization by the respective
government entity will be required for export of those products.
Trademarks and Notice
The contents of this document are subject to change without notice. This document may contain information on a Cypress
product under development by Cypress. Cypress reserves the right to change or discontinue work on any product without
notice. The information in this document is provided as is without warranty or guarantee of any kind as to its accuracy,
completeness, operability, fitness for particular purpose, merchantability, non-infringement of third-party rights, or any other
warranty, express, implied, or statutory. Cypress assumes no liability for any damages of any kind arising out of the use of
the information in this document.
®
Copyright © 2015 Cypress Semiconductor Corp. All rights reserved. Cypress, the Cypress logo, Spansion , the Spansion
®
®
TM
TM
TM
TM
logo, MirrorBit , MirrorBit Eclipse , ORNAND , Easy DesignSim , Traveo and combinations thereof, are trademarks
and registered trademarks of Cypress Semiconductor Corp. in the United States and other countries. Other names used are
for informational purposes only and may be trademarks of their respective owners.
18
CONFIDENTIAL
S6SBP501A00VA1001_SS901-00044-1v0-E, September 25, 2015
v1.1