POWER ENTRY MODULE EMI FILTERS SERIES SPECIFICATIONS INTRODUCTIONS 1. Power module incorporates an IEC connector, single or doublefuse (IEC 5 x 20mm ) holder, optional voltage selector switch and double-pole power switch, plus an EMI filter all-in-one easy-to-install unit. 2. Adapts to 110-120V or 220-240V input voltage by simply reversing the fuse cartridge. 3. All part numbers are UL recognized, CSA certified and VDE approved. 4. Switch electrical lifetime: 10,000 cycles. Maximum inrush current: 70A. 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC COMPONENTS V D E PART NO. L (mH) Cx (uF) Cy (pF) R( PART NO. 10EB3 ) 03EB3 03EB3A 03EB3S 03EB3SA 06EB3 06EB3A 06EB3S 06EB3SA L (mH) Cx (uF) Cy (pF) 1.6 0.22 3300 1M Cx (uF) 0.01 Cy (pF) 2200 R( ) 1M 10EB3A 10EB3S 10EB3SA 8 0.22 3300 1M R( ) Lg: 400 uH (EB3A, EB3SA only) 2.5 V D E PART NO. 05EB3B/S L (mH) 0.93 TYPE & FEATURE DELTA PART NO. POWER ENTRY MODULE FILTERS FUSE IEC CONNECTOR DOUBLE POLE POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC 03EB3 05EB3B 03EB3A 03EB3S 05EB3BS 03EB3SA 06EB3 10EB3 DOUBLE 06EB3A 10EB3A DOUBLE 06EB3S 10EB3S SINGLE 06EB3SA 10EB3SA SINGLE FIG.A FIG.B FIG.A FIG.B UL, CSA & VDE approved current rating: UL_10A both at 125VAC & 250VAC; CSA & VDE-6A at 250VAC. UL, CSA & VDE approved current rating: UL & CSA_10A both at 125VAC & 250VAC; VDE_10A at 250VAC. ELECTRICAL SCHEMATIC SW 1 F SW L L I N E 2 Cx L O A D Cy R L Cy 3 N G G' L L I N E 110V 110V 4 1 F 2 Cx L O A D Cy R L Cy N 3 G 4 G' Lg FOR XXEB3SA FOR XXEB3S EB3A, EB3SA FIG. B FIG. A 4-8 110V 110V INSERTION LOSS (TYPICAL) DIFF. MODE DIFF. MODE COMMON MODE COMMON MODE 03EB3 06EB3 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB 0 dB 1M 100K 10K 0 dB 10M DIFF. MODE COMMON MODE 10EB3 1M 100K 10K 10M MINIMUM INSERTION LOSS IN dB DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT RATING 0.05 3A (S) 20 6A (S) 10A (S) 3A (A,SA) 6A (A,SA) 10A (A,SA) 10 10 20 10 10 FREQUENCY-MHz 0.10 0.15 0.50 1.0 5.0 25 30 38 38 38 15 15 25 15 15 20 20 30 20 20 30 20 40 25 25 35 30 40 30 30 40 40 40 40 45 10 38 30 25 40 40 45 45 50 30 30 30 30 30 3A (S) 2 9 12 30 40 30 40 30 6A (S) 10A (S) 3A (A,SA) 6A (A,SA) 10A (A,SA) 2 2 2 2 2 5 5 8 5 5 8 8 12 10 8 20 15 30 15 20 30 30 40 30 30 30 40 35 45 50 45 45 40 50 50 40 35 30 40 40 +0.02 2.37-0 +0.5 60.2-0 +0.02 1.14-0 +0.5 29.0-0 1.575 0.004 40.0 0.1 1.99MAX. 50.5MAX. 1.575 0.02 40.0 0.5 110-120V 220-240V 1.12 0.02 28.4 0.5 MECHANICAL CONSTRUCTION USE ONLY WITH 250V FUSES/EMPLOYER UNIQUEMENT AVEC DES FUSIBLES DE 250V 2.58MAX. 65.5MAX. M3(2X) R0.0984MAX. R2.5MAX. 0.13(2X) 3.3(2X) 2.37MAX. 60.2MAX. 4-9 3.28MAX. 83.3MAX. 3.51MAX. 89.2MAX. SUGGESTED MOUNTING CUTOUT (MOUNTING FROM FRONT) 1.14MAX. 29.0MAX. UNIT: INCH mm POWER ENTRY MODULE FILTERS CSA approved 6A at 125/250 VAC; VDE-6A/250VAC