PNA2P020

P/ALA/PNA2P020/B/28/10/2014
page 1 / 5GB
Anti intrusion MAGNETIC SENSOR
for Windows and Doors Alarms
PNA2P020
→ PNA2P020 magnetic sensor is used in doors and windows access control
systems for buildings.
PNA2P020 magnetic sensor is built in two parts : "contact" and "magnet"
The switch is open without magnet presence.
→ Wiring: 2 meters cable with 4 wires : 2 for the switch
and 2 for autoprotection circuit.
REED switech contact without external supply (see figure 1)
→ Built in plastic housing with 2 mounting possibilites:
Figure 2 : 2 diameter 8mm "contact" (2) and "magnet" (1) directly installed
Figure 3 : "contact" and "magnet" mounted inside an other plastic housing (3)
This additional plastic housing has different parts :
- Socket (3) : the "contact" cable can be on the right or on the left
- Cover (5) : to mask screws mounting
- Spacers (4) to adjust the mounting.
→ PNA2P020 magnetic sensor is designed in compliance with EN 50131
concerning Alarm Systems - Intrusion and Hold-Up Systems
figure 1
→ Certification NF-A2P 3 shields – Certification REFERENCE NF324-H58
N°: 2133300001A0
By : CNPP - Département Certification - CNPP Cert.
Route de La Chapelle Réanville - CS22265 27950 SAINT MARCEL
FRANCE
Tel : (33) 2.32.53.63.63 - Fax : (33) 2.32.53.64 46
Web site : http://www.cnpp.com
stripped conductors
for contact
figure 2
figure 3
1 : Magnet
2 : contact = magnetic REED
3 : Socket Housing for mounting
4 : Spacers
5 : Cover
CAD documents: www.celduc-relais.com/uk/plan3d.asp
Proud to serve you
All technical caracteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
celduc
r
e
l
a
i
s
®
P/ALA/PNA2P020/B/28/10/2014
page 2 / 5GB
SPECIFICATIONS
Plastic housing material
Mounting support
Mounting
Autoprotection
Output alarm
Maximum voltage
Maximum current
Maximum Power
Connection
Life time expectancy
Contact resistance
Using temperature
Storage temperature
Humidity
Degree of protection
Cable length
Sensor and magnet dimensions
Additional housing dimensions
Socket housing dimensions
Total weight
ABS
Wood, Plastic, aluminum or iron (with some reservs)
Direct or throught an additional housing
Yes
Normally closed with magnet
VDC / VAC 48 Volts
VDC / VAC 1 A
10 W
Wires
>25 millions of operations .(10mA, 12 V)
<600 mΩ a 20°C
-10°....+55°C
-10°....+55°C
RH 95%
IP43 IK02
2 meters
Diameter 8 mm X length 35mm
45 x 16,5 x 11 mm
45 X 16,5 X 4 mm
52 g
I- Direct mounting
(only on non iron materials)
1) Check that there is no excessive distances between the frame and the mobile part.
Respect the detection distances of table 1
2) Check that the frames have sufficient depth to accommodate both sides of the contact.
(In general the " contact" is mounted on the fixe window frame and the magnet on the
mobile frame) .
3) Check the position of the cable
4) For mounting the " contact", a hole of Ø 8 mm with the suitable drill perforating according
the material .
5) Release the hole residues or chips and trimming if necessary .
6) Insert the cable into the contact hole
7) Insert the sensor into the hole and push without tools that could damage it.
8) The mounting instructions for the magnetic part is similar.
Table 1: Activation distances ( direct mounting)
Operate distance on wood, plastic and aluminum
Axys X
Axys Y
Axys Z
13mm
14mm
14mm
Non Operate distance on wood, plastic and aluminum
Axys X
Axys Y
Axys Z
26mm
25mm
25mm
Other possibilty
(axe Z)
celduc
r
e
l
a
i
®
s
www.celduc.com
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
P/ALA/PNA2P020/B/28/10/2014
page 3 / 5GB
II- mounting throught additional housing
1) Check that there is no excessive distances between the frame and the mobile part.
2) Check that the frames have sufficient depth for screws mounting.
3) Disposed in parallel the two housings (one on the frame and one on the mobile part).
Respect the detection distances of table 2
Align the two small arrows
4) Mark and practice holes for the screws. Spacing = 16mm
Use the drill bit most suitable depending on the media type and screw
(see table "3") to be used for fixing.
5) Remove the thin-walled plastic housing on the side you want the position of relase
cable and remove burrs.
6) Insert the sensor and fix it with the screws.
If there are differences between the two fixing surfaces insert one or more spacers
to have the two parts on the same level.
For systems on iron surfaces, it is essential to use at least one spacer for each of
the contact part.
7) Set the magnet assembly in accordance with the parts according to Figure 3.
Block head screws with cyanoacrylate glue.
8) Fit and tighten the two covers with cyanoacrylate glue.
Table 2 : Activation distances ( through additional housing)
Material
Wood, plastic, aluminum
Iron (*)
Material
Operating distances
Axys X
Axys Y
14mm
15mm
7mm
7mm
Axys Z
7mm
5mm
Non Operating distances
Axys X
Axys Y
30mm
35mm
17mm
26mm
Axys Z
20mm
15mm
Wood, plastic, aluminum
Iron (*)
(*) distances must be verified on iron
Table 3 : Screws specifications
Minimum penetration into the substrate
wood 8mm / 4 mm métal
max screw
max head screw
H max of head screw
3,2 mm
3,8 mm
2,3 mm
CHECK and TESTS
When door/window is open and close , check the proper functionning by using a multimeter ( self protection always ON
Then, connect the multimeter on the two wires of the contact alarm ( stripped conductors)
By operating the door or the windows, verify the contact switch ON and OFF.
The causes of false alarms may depend on higher clearances between fixed and mobile parts.
Any installation that does not meet the maximum distance and alignment between the fixed part and the movable part can
generate false alarms or malfunction contact.
WIRING
If it is impossible to pass the cable through the frame, secure it with small jumpers or pass it in a built-in wall sleeve.
The cable should not be stretched.
The 2 stripped conductors correspond to the "contact"
The 2 others for the "autoprotection" circuit
celduc
r
e
l
a
i
®
s
www.celduc.com
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
P/ALA/PNA2P020/B/28/10/2014
page 4 / 5GB
Dimensions et mounting
For dimensions details : www.celduc-relais.com/uk/plan3d.asp
Direct mounting:
Same housing for "contact" and "magnet"
Drilling Ø 8 mm
4 wires cable with a diameter of 3.7mm
Length 2 meters
Wires and housing color : white
Additional housing
2 diameter 3.3mm in plastic housing
Holes spacing 16mm
Sensor with cable on the
right
Sensor with cable on the
left
sensor and magnet
Magnet
Use adapted tools
No external magnetic field
celduc
r
e
l
a
i
s
®
www.celduc.com
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
P/ALA/PNA2P020/B/28/10/2014
page 5 / 5GB
Typical wiring
1 sensor
sensor
autoprotection
Many sensors in series
Open contact without magnet
(door or windows open)
Closed contact with magnet
(door or windows closed)
celduc
r
e
l
a
i
s
®
www.celduc.com
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19