VZS/C-3529J1

S/C-Band
2000 Watt TWT Compact Pulse Amplifier
Compact
Five rack-units tall (8.75 in/222 mm).
Versatile
Ultra-wideband, automatic fault recycle, user-friendly
microprocessor-controlled logic with integrated computer
interface, digital metering, electronic variable attenuation ,
soft fail when subjected to extreme load SWR conditions, and
quiet operation suitable for laboratory environments.
An integral solid state preamplifier and IEEE interface are
included as standard features.
Global Applications
230 VAC operation. Designed to meet International Safety
Standard EN61010 and Electromagnetic Compatibility EMC
2004/108/EC.
Model VZS/C-3529J1
2.0 Compact Pulse Amplifer
for Test and Measurement
Applications
OPTIONS
•Remote Control Panel
•Input Isolator (-1 dB Gain)
Easy to Maintain
Modular design and built-in fault diagnostic capability backed
by CPI’s worldwide 24-hour customer support network that
includes over twenty regional factory service centers.
45 River Drive
Georgetown, Ontario, Canada L7G 2J4
tel:
+1 (905) 702-2228
fax:
+1 (905) 877-5327
e-mail:[email protected]
website:www.cpii.com/emc
S/C-Band
Specifications 2000 Watt TWT Compact Pulse Amplifier
Specification
Model VZS/C-3529J1
Frequency
2.0 to 8.0 GHz
Output Power (min.), TWT
Output Power (min.), Flange
2200 W
2000 W
63 dB min. at rated power output;
65 dB min. at small signal
Gain
RF Level Adjust Range
0 to 20 dB
Gain Stability
±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.)
Input VSWR
2.5:1 max;
2.0:1 max. with optional input isolato
Output VSWR
2.5:1 typ.
Load VSWR
1.5:1 max. for full spec. compliance;
Any value for continuous operation (soft fail VSWR protection limits at 500 W peak)
Phase Noise
0.5°rms asynchronous ripple
Pulse Width
0.07 to 50 µs
PRF
-50 kHz max, 100 kHz max. available as option
Duty Cycle
6% max.
Delay
300 ns typ., 400 ns max.
Droop
0.5 dB over 50 µs
Harmonic Content
-3 dBc typ. at lower band edge, decreasing to -15 dBc typ. at upper band edge
-15 dBm/MHz Beam On;
-110 dBm/MHz Beam Off
NPO
Primary Power
220 - 240 VAC ±10%, single phase 47- 63 Hz
2.6 kVA typ.
3.0 kVA max.
Power Consumption
Filament Voltage
Reduction of 10% in standby for extended TWT life (available as option)
Inrush Current
200% max.
Shock
200% max.
10° to +40°C operating
-40° to +70°C non-operating
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
95% non-condensing
10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
As normally encountered in a protected laboratory environment
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Cooling (TWT)
Forced air with integral blower
Rear air intake & exhaust;
0.10” water max. external pressure loss allowable
Weight
65 lbs (29.5 kg) nom.
RF Input Connection
Type N female
RF Output Connection
Type N female
RF Output Monitor
Type N female, -50 dB nominal
Dimensions (W x H x D)*
19 x 8.75 x 26 in. (483 x 223 x 661 mm)
Weight
120 lbs (55 kg) max.
Heat Dissipation
700 watts (TBD)
Safety
EN61010
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 245, ISSUE 9 dated AUG 2015