S/C-Band 2000 Watt TWT Compact Pulse Amplifier Compact Five rack-units tall (8.75 in/222 mm). Versatile Ultra-wideband, automatic fault recycle, user-friendly microprocessor-controlled logic with integrated computer interface, digital metering, electronic variable attenuation , soft fail when subjected to extreme load SWR conditions, and quiet operation suitable for laboratory environments. An integral solid state preamplifier and IEEE interface are included as standard features. Global Applications 230 VAC operation. Designed to meet International Safety Standard EN61010 and Electromagnetic Compatibility EMC 2004/108/EC. Model VZS/C-3529J1 2.0 Compact Pulse Amplifer for Test and Measurement Applications OPTIONS •Remote Control Panel •Input Isolator (-1 dB Gain) Easy to Maintain Modular design and built-in fault diagnostic capability backed by CPI’s worldwide 24-hour customer support network that includes over twenty regional factory service centers. 45 River Drive Georgetown, Ontario, Canada L7G 2J4 tel: +1 (905) 702-2228 fax: +1 (905) 877-5327 e-mail:[email protected] website:www.cpii.com/emc S/C-Band Specifications 2000 Watt TWT Compact Pulse Amplifier Specification Model VZS/C-3529J1 Frequency 2.0 to 8.0 GHz Output Power (min.), TWT Output Power (min.), Flange 2200 W 2000 W 63 dB min. at rated power output; 65 dB min. at small signal Gain RF Level Adjust Range 0 to 20 dB Gain Stability ±0.25 dB/24hr max. (after 30 minute warmup and at constant drive and temp.) Input VSWR 2.5:1 max; 2.0:1 max. with optional input isolato Output VSWR 2.5:1 typ. Load VSWR 1.5:1 max. for full spec. compliance; Any value for continuous operation (soft fail VSWR protection limits at 500 W peak) Phase Noise 0.5°rms asynchronous ripple Pulse Width 0.07 to 50 µs PRF -50 kHz max, 100 kHz max. available as option Duty Cycle 6% max. Delay 300 ns typ., 400 ns max. Droop 0.5 dB over 50 µs Harmonic Content -3 dBc typ. at lower band edge, decreasing to -15 dBc typ. at upper band edge -15 dBm/MHz Beam On; -110 dBm/MHz Beam Off NPO Primary Power 220 - 240 VAC ±10%, single phase 47- 63 Hz 2.6 kVA typ. 3.0 kVA max. Power Consumption Filament Voltage Reduction of 10% in standby for extended TWT life (available as option) Inrush Current 200% max. Shock 200% max. 10° to +40°C operating -40° to +70°C non-operating Ambient Temperature Relative Humidity Altitude Shock and Vibration 95% non-condensing 10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 40,000 ft., non-operating As normally encountered in a protected laboratory environment Acoustic Noise 65 dBA @ 3 ft. from amplifier Cooling (TWT) Forced air with integral blower Rear air intake & exhaust; 0.10” water max. external pressure loss allowable Weight 65 lbs (29.5 kg) nom. RF Input Connection Type N female RF Output Connection Type N female RF Output Monitor Type N female, -50 dB nominal Dimensions (W x H x D)* 19 x 8.75 x 26 in. (483 x 223 x 661 mm) Weight 120 lbs (55 kg) max. Heat Dissipation 700 watts (TBD) Safety EN61010 Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 245, ISSUE 9 dated AUG 2015