MKT-344 VZL-3530P2.indd - Communications & Power Industries

8.0 kW Combined Pulse Amplifier
for Test and Measurement Applications
1 .0 to 2 .0 GHz
Versatile
Modular assembly allows for either lowerpowered multiple test applications or a single
amplifier phase combined system of two
VZL-3530J1 amplifiers achieving 8000 watts
peak-pulsed output power.
The VZL-3530P2
1.0 to 2.0 GHz
8000 Watt TWT
Compact Pulsed
Amplifier
Wide band, automatic fault recycle, user-friendly
microprocessor-controlled logic with integrated
computer interface, digital metering, and quiet
operation suitable for laboratory environments.
An integral solid state preamplifier and IEEE
interface are included as standard features.
Global Applications
230 VAC operation. Designed to meet
International Safety Standard EN61010 and
Electromagnetic Compatibility 2004/108/EC.
Easy to Maintain
Modular design and built-in fault diagnostic
capability backed by CPI’s worldwide 24-hour
customer support network that includes twenty
regional factory service centers.
tel: +1 (905) 877-0161
fax: +1 (905) 877-5327
e-mail: [email protected]
www.cpii.com/satcom
7.0 kW Compact Pulsed Amplifier
Communications & Power Industries Canada, Inc.
45 River Drive
Georgetown, Ontario CANADA L7G2J4
1.0 t o 2. 0 GH z
SPECIFICATIONS, VZL-3530P2
Environmental
Electrical
OPTIONS:
• Remote Control Panel
• Input Isolator
(-1 dB Gain)
Frequency
1.0 to 2.0 GHz
Ambient Temperature
Output Peak Power (min.)
TWT
Flange
-10° to +40°C operating
-40° to +70°C non-operating
9000 W combined
8000 W combined typ, 7500 W min.
Relative Humidity
95% non-condensing
Altitude
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
As normally encountered in a
protected laboratory environment
Gain
65 dB min. at rated power;
70 dB typical
Gain Adjustment Range
20 dB min.
Shock and Vibration
Gain Stability
±0.25 dB/24hr max. (after 30 minute warmup
and at constant drive and temp.)
Mechanical
Input VSWR
2.5:1 typ;
1.5:1 typ. with optional input isolator
Output VSWR
2.5:1 typ.
Load VSWR
Cooling (TWT)
Forced air with integral blower
Rear air intake & exhaust;
0.10" water max. external pressure
loss allowable
1.5:1 max. for full spec. compliance;
Any value for continuous operation (soft fail
VSWR protection limits at 500 W peak)
RF Input Connection
Type N female
RF Output Connection
S/C coaxial
Phase Noise
0.5°rms asynchronous ripple
Dimensions (W x H x D)*
Pulse Width
0.07 to 50 µs
19 x 37 x 27.5 in.
(483 x 940 x 699 mm)
PRF
50 kHz max, 100 kHz max. available as option
System Weight
300 lbs (136 kg)
Duty Cycle
4% max.
Heat Dissipation
2200 watts max.
Delay
400 ns typ.
Safety
EN61010
Droop
0.5 dB over 50 µs
Acoustic Noise
65 dBA @ 3 ft. from amplifier
NPO
-10 dBm/MHz Beam On;
-110 dBm/MHz Beam Off
*Dimension exclude front handles, rear fans and exhaust ducts.
Primary Power
220 - 240 VAC ±10%,
single phase 47- 63 Hz
Power Consumption
2.2 kVA typ.
2.5 kVA max.
Filament Voltage
Reduction of 10% in standby for extended
TWT life (available as option)
Inrush Current
200% max.
This product is subject to the U.S. International Traffic in Arms Regulations (ITAR).
Sale of this product is subject to US Government approval. In accordance with part 126.1
of the ITAR, it is the policy of the United States to deny licenses and other approvals for
the sales, exports/ imports, and or transfer of items subject to the ITAR destined for or
originating in certain countries in which the U.S. maintains an arms embargo.
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 344, ISSUE 5
DEC 13