Download Data Sheet

Rev. A
PSDN-100 Series
Active PFC
96 Watt, Single output
AC/DC DIN Rail Power Supply
FEATURES
● Single Output
● RoHS Compliant
● True DC OK Relay Contact
● Withstand 5G Vibration Test
● Universal AC Input 88~264VAC
● Installed on DIN Rail TS35 / 7.5 or 15
● UL1310 Class 2 Power Unit / LPS Pass
● High Operating Temperature up to 70°C
● UL508 (Industrial Control Equipment) Listed
● Built-in Active PFC and Over Temp Protection
● High Efficiency, Long Life, and High Reliability
● All Using 105°C Long Life Electrolytic Capacitors
● Short Circuit, Over Load, and Over Voltage Protection
DESCRIPTION
The PSDN-100 series of AC/DC DIN Rail power supplies provides 96 Watts of continuous output power. All models have a single
output, active PFC, and a universal input range. All models are over load, over voltage, over temp, and short circuit protected.
SPECIFICATIONS: PSDN-100 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
Input Voltage Range (See Note 3)
88 ~ 264VAC or 124 ~ 370VDC
Input Frequency
47 to 63Hz
AC Current (typical)
1.1A at 115VAC, 0.55A at 230VAC
Inrush Current (typical)
Cold Start 30A at 115VAC,
60A at 230VAC
Leakage Current
< 1mA at 230VAC
Power Factor (typical)
>0.98 at 115VAC and full load, >0.92 at 230VAC and full load
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Output Power
See Table
Output Voltage Adjustability
±10%
Voltage Tolerance (See Note 2)
±1.0%
Line Regulation
±1.0%
Load Regulation
±2.0%
Output Current
See Table
Ripple & Noise (See Note 1)
See Table
Setup, Rise Time
< 800ms, <40ms @ 230VAC and full load
Hold Up Time (typical)
> 16ms at 115VAC and full load, > 32ms at 230VAC and full load
PROTECTION
115% ~ 150% rated output voltage
Over Voltage Protection
Protection Type: Latch-off mode
> 105°C rated output power
Over Load Protection
Protection type: constant current limiting, automatically after fault condition is removed.
Over Temperature Protection
90°C with N2 sense by inside Air Temp.
GENERAL SPECIFICATIONS
Efficiency
See Table
Withstand Voltage
I/P - O/P: 4242VDC, I/P - FG: 2121VDC for 1 minute
Isolation Resistance
I/P - O/P, I/P - FG, O/P - FG: 100MΩ / 500VDC
DC OK Signal
Relay contact (30VDC / 1A, 120VAC / 1A)
ENVIRONMENTAL SPECIFICATIONS
Working Temperature
-20°C ~ +70°C (refer to output load derating curve)
Storage Temperature
-40°C ~ +85°C
Working Humidity
20% ~ 90% RH, non-condensing
Storage Humidity
10% ~ 95% RH
Vibration
10 ~ 500Hz, 5G 0.5Oct/min, period for 60 min., Each along X,Y,Z axes.
Cooling
Free Air Convection
Temperature Coefficient
±0.03% / °C (0 ~ 50°C)
PHYSICAL SPECIFICATIONS
Packing
14.11oz (400g)
Dimensions (W x H x D)
2.17 x 3.54 x 3.90 inches (55 x 90 x 99 mm)
Connection
I/P: 3 poles, O/P: 6 poles screw DIN terminal
SAFETY & EMC (See Note 4)
Safety Standards
UL 508, TUV EN60950-1, UL1310 NEC class 2 compliant (only for 24V and 48V models)
EMI Conduction & Radiation
EN55022: 2006 (Class B), EN61204-3: 2000, EN61000-6-3: 2007
Harmonic Current
EN61000-3-2,3: 2006
EMS Immunity
EN55024, EN61204-3: 2000, EN61000-6-1: 2007 (EN61000-4-2,3,4,5,6,8,11)
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
PSDN-100 Series
Active PFC
96 Watt, Single output
AC/DC DIN Rail Power Supply
Rev. A
MODEL SELECTION TABLE
Model Number
Input Voltage
Output Voltage
Output Current
Rated Output Power
Ripple & Noise (1)
Efficiency
PSDN-100-12
88 ~ 264VAC
(124 ~ 370VDC)
12 VDC
7.5A
90W
180mVp-p
87%
PSDN-100-15
88 ~ 264VAC
(124 ~ 370VDC)
15 VDC
6.4A
96W
180mVp-p
87%
PSDN-100-24
88 ~ 264VAC
(124 ~ 370VDC)
24 VDC
4A
96W
180mVp-p
88%
PSDN-100-48
88 ~ 264VAC
(124 ~ 370VDC)
48 VDC
2A
96W
250mVp-p
87%
NOTES
1. Ripple & noise is measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 47µF capacitors
in parallel.
2. Tolerance includes set up tolerance, line regulation, and load regulation.
3. Derating may be needed under low input voltages. Please check the derating curve for more details.
4. The power supply is considered a component, which will be installed into final equipment. The final equipment must be
re-confirmed that it still meets EMC directives.
5. In parallel connection only one unit may operate if the total output load is less than 5% of the rated load.
BLOCK DIAGRAM
DC OK RELAY CONTACT
Contact Close
When the output voltage reaches the adjusted output voltage
Contact Open
When the output voltage drops below 90% output voltage
Contact Ratings (max.)
30V / 1A resistive load
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
PSDN-100 Series
Active PFC
96 Watt, Single output
AC/DC DIN Rail Power Supply
Rev. A
DERATING CURVES
Load vs Temperature
Load vs Input Voltage
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
40
80
70
60
50
20
-20
40
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
85
100
110
Input Voltage (VAC) 60Hz
MECHANICAL DRAWING
Unit: inches (mm)
2.17 (55)
1.38 (35)
0.2 0.2 0.2 0.2 0.2
(5) (5) (5) (5) (5)
3.54 (90)
Install DIN Rail TS35/7.5 or TS35/15
120
0.30 0.30
(7.5) (7.5)
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
3.90 (99)
264