MODULE GROUP B TESTING
For Module H3
TEST
CONDITION
MIL-STD-750
TEST
METHOD
SUBGROUP 1
Solderability
Resistance to
Solvents
SAMPLE
PLAN
(Units)
SMALL
LOT
(Units)
15 c=0
4 c=0
22 c=0
6 c=0
45 c=0
12 c=0
2026
1022
SUBGROUP 2
Temp Cycle
-65°C to +150°C, 10 cycles, 30 minutes each
extreme
1051
Electrical
Reverse Current (IR) @ rated VWM
Breakdown Voltage (V(BR)) @ IT
4016
4022
SUBGROUP 3
Electrical
Reverse Current (IR) @ rated VWM
Breakdown Voltage (V(BR)) @ IT
4016
4022
Operating Life
@ rated VWM, TA = +125°C for 340 hours
1026
Reverse Current (IR) @ rated VWM, D-IR = 50% or
1µA, whichever is greater
Breakdown Voltage (V(BR)) @ IT, D-V(BR) ±5% from
initial reading
4016
Electrical
4022
Note: For bidirectional devices, test both polarities – split hours on Operating Life to 50% each polarity.
Attributes Data Supplied
Sampling per MIL-PRF-19500
Module – H3(Group B)
05234.R0 03/10
ProTek Devices
2929 S. Fair Lane ● Tempe, Arizona ● 85282
Tel: 602-431-8101 ● Fax: 602-431-2288
Email: [email protected] ● Web: www.protekdevices.com