High-reliability discrete products and engineering services since 1977 HR FLOW TRANSIENT VOLTAGE SUPPRESSORS All parts are screened per MIL-PRF-19500, JANTX Level and the device detail specification. All testing is performed at room temperature, unless indicated otherwise. For testing at high and low temperatures, Group A testing is required. Test Method Conditions / Notes 1 Temperature Cycling MIL-STD-750 Method 1051 2 Current Surge Peak Pulse Current (IP) 10/1000µs peak current (IP) Test condition C or maximum storage temperature, whichever less. 20 cycles, 10 minutes per extreme. 10 surges in each direction or as specified in detail specification. 3 Interim Electrical Testing 4 Power Burn-in 5 Final Electrical Testing Condition B, 96 hours minimum. 48 hours in each polarity for bidirectional. Per device detail specification. 6 Delta Calculation Per device detail specification. 7 PDA Calculation 10 percent defective allowed. 8 Seal Test Gross Leak Per device detail specification. MIL-STD-750 Method 1038 MIL-STD-750 Method 1071 No bubbles present. Notes: 1. Testing varies in accordance with the device detail specification. 2. Specific customer testing needs may be accommodated into any testing flow (selection tests, temperature requirements, special tests). 144 Market Street Kenilworth NJ 07033 USA phone +1.908.245-7200 fax +1.908.245-0555 [email protected] www.digitroncorp.com