High-reliability discrete products
and engineering services since 1977
HR FLOW
TRANSIENT VOLTAGE SUPPRESSORS
All parts are screened per MIL-PRF-19500, JANTX Level and the device detail specification. All
testing is performed at room temperature, unless indicated otherwise. For testing at high and low
temperatures, Group A testing is required.
Test
Method
Conditions / Notes
1
Temperature Cycling
MIL-STD-750 Method 1051
2
Current Surge Peak
Pulse Current (IP)
10/1000µs peak current (IP)
Test condition C or maximum
storage temperature, whichever
less. 20 cycles, 10 minutes per
extreme.
10 surges in each direction or as
specified in detail specification.
3
Interim Electrical
Testing
4
Power Burn-in
5
Final Electrical Testing
Condition B, 96 hours minimum.
48 hours in each polarity for
bidirectional.
Per device detail specification.
6
Delta Calculation
Per device detail specification.
7
PDA Calculation
10 percent defective allowed.
8
Seal Test Gross Leak
Per device detail specification.
MIL-STD-750 Method 1038
MIL-STD-750 Method 1071
No bubbles present.
Notes:
1. Testing varies in accordance with the device detail specification.
2. Specific customer testing needs may be accommodated into any testing flow (selection
tests, temperature requirements, special tests).