Product Sheet

V I S H AY I N T E R T E C H N O L O G Y, I N C .
VISHAY ESTA POWER CAPACITORS
ESTAmat
Power Factor Correction Controllers
KEY BENEFITS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1...6 steps and 1...12 steps
Supply voltage from 90 VAC to 300 VAC (model ESTAmat PFC-N)
Measuring voltage from 90 VAC to 690 VAC, galvanic separation (model ESTAmat PFC-N)
Operating voltage of 230 VAC ± 10 % (model ESTAmat MH-N)
No need to differentiate between X/1 A or X/5 A current transformer
High contrast backlit display for good reading even in poor lighting conditions
Over-temperature switch-off (model ESTAmat PFC-N)
Easy mounting with small flat springs
Automatic self-setting (model ESTAmat PFC-N)
4-quadrant operation means trouble-free service in generator mode
Optimized switching performance
Constant display of actual power factor and energized steps
Display of cos φ, P, Q, and S
Additional step data (model ESTAmat PFC-N)
Alarm functions
APPLICATIONS
• Automatic and manual control of central PFC equipment
RESOURCES
• Manual: ESTAmat MH-N - http://www.vishay.com/doc?13156
• Manual: ESTAmat PFC-N - http://www.vishay.com/doc?13157
• For technical questions contact [email protected]
A WORLD OF
SOLUTIONS
Product Sheet
1/2
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND
THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VMN-PT0212-1602
www.vishay.com
V I S H AY I N T E R T E C H N O L O G Y, I N C .
VISHAY ESTA POWER CAPACITORS
ESTAmat
Power Factor Correction Controllers
HOW DO THEY COMPARE WITH EACH OTHER:
MATTER OF REFERENCE
ESTAmat PFC-N
ESTAmat MH-N
Measuring and operating voltage
Galvanic separation
Galvanic separation
Connection of measuring voltage
Phase / Neutral
or
Phase / Phase
Phase / Neutral
internally connected to the operating
voltage
Measuring voltage
90 VAC to 690 VAC
Operating voltage
90 VAC to 300 VAC
Initialization of C.T. location and output
and number of the capacitor steps
(switching program)
Optionally
auto-initializing and manual setting
Manual
Identification of C.T. location
Yes
No
Defining fixed steps
Yes
No
Switching time
One time between
1 s to 6500 s
asymmetrical switching
One time between
2 s to 1800 s
for switching on and off
Re-switching blocking delay time
Stepless
500 ms to 1200 s
Adjustable together with switching time
2 s to 1800 s
Switching mode
Circular and series
Circular
Display of cos ϕ; P; Q; S; Urms; Irms
Yes
Yes
Display of the percentage amount of the
harmonic voltage 3rd, 5th, 7th, 9th, 11th,
13th, 17th, and 19th (FFT)
Temp.; Qc switching per step
Yes
No
Temperature control by means of
an internal sensor
Range: 0 up to + 70 °C (step size 1 °C)
Yes
No
External interface
Yes
No
230 V ± 10 %
DIMENSIONS
ESTAmat
Front panel
144 mm x 144 mm
Panel cut-out
Product Sheet
138 mm x 138 mm (± 0.5 mm)
2/2
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND
THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
VMN-PT0212-1602
www.vishay.com