TB-200: Solder Reflow Profile for Select Devices

Technical Brief: TB-200
INTEGRATED CIRCUITS DIVISION
Pb-Free Solder Reflow Profile
for Select Devices
TB-200-R01
www.ixysic.com
1
Technical Brief: TB-200
INTEGRATED CIRCUITS DIVISION
IXYS Integrated Circuits Division is providing the following lead-free solder reflow temperature profile for a small
number of optically coupled devices whose data sheet specifies the solder reflow profile given in Technical Brief
TB-200 "Pb-Free Solder Reflow Profile for Select Devices" must be followed. This profile is similar to that
provided in J-STD-020 with a few subtle differences to minimize damage during the reflow process caused by
moisture retention of the package. One modification splits the Preheat stage into two sections, Preheat 1 and
Preheat 2. Preheat 1 is used to improve water vapor removal from the package while Preheat 2 rounds out the
preheat temperature increase specified in J-STD-020. The other modification to the JEDEC profile is the reduction
of the maximum time the body temperature of the device is within 5°C of the classification temperature. This dwell
time, identified as tp in the profile below, is limited to 15 seconds.
In addition to these modifications the maximum ramp rate over any time range during "Time 25°C to Peak" is
restricted to 3°C/s.
Solder Reflow Profile
Tc
Tp
Ramp-Up
Max. Rate = 3ºC/s
Temperature
TL
Tsmax
tp
15s max
Tc - 5ºC
Ramp-Down
Max. Rate = 6ºC/s
tL
60s - 150s
Tsmid
Preheat 2
Tsmin
ts2
Preheat 1
ts1
(180ºC - 200ºC)
30s - 60s
(150ºC - 180ºC)
60s - 120s
25ºC
Time 25ºC to Peak
TIME
1.
2.
3.
4.
5.
6.
7.
8.
(Note: Drawing is not to scale)
Tc - Classification temperature: maximum body temperature rating of the device as given in the data sheet.
Tp = Peak package body temperature during the soldering reflow process, Tp < Tc.
TL = 217°C = Liquidus temperature of Pb-free solder.
Preheat / Soak period:
• Tsmin = 150°C = Body temperature at the beginning of the preheat step.
• Tsmid = 180°C = Temperature marking end of Preheat 1 and the beginning of Preheat 2.
• Tsmax = 200°C = Body temperature attained at the end of the preheat period.
tL = Time maintained above TL.
Time 25°C to Peak < 8 minutes.
tp = time within 5°C of classification temperature.
Maximum ramp rates are true maximums over any time range (not average).
Note: Body temperature is based on temperature sensor positioned at the center of the package surface facing
upward during the solder reflow procedure.
2
www.ixysic.com
R01
Technical Brief: TB-200
INTEGRATED CIRCUITS DIVISION
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its
products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
Specification: TB-200-R01
©Copyright 2015, IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
11/10/2015
R01
www.ixysic.com
3