DATA SHEET
SKY13385-460LF: 0.1 to 3.5 GHz SP3T Switch
Applications
J3 V3
 802.11 b/g WLANs
 Bluetooth®
Features
 Broadband frequency range: 0.1 to 3.5 GHz
 Low insertion loss: 0.5 dB @ 2.45 GHz
 High isolation: 32 dB up to 2.45 GHz
 No external DC blocking capacitors required
 Positive low voltage control: VCTL = 1.650 to 3.465 V,
VDD = 2.5 to 5.5 V
 Small, QFN (12-pin, 2 x 2 mm, 0.5 mm pitch) package
(MSL1, 260 C per JEDEC J-STD-020)
GND
RFC
GND
Skyworks Green™ products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of Green™, document number
SQ04-0074.
12
11
10
GND
2
8
GND
J3
3
7
VDD
6
V3
J2
V2
9
V1
1
5
V2
Y2359
V1 J1
Figure 1. SKY13385-460LF Block Diagram
Description
The SKY13385-460LF is a CMOS silicon-on-insulation (SOI),
single-pole, triple-throw (SP3T) switch. The high linearity
performance and low insertion loss makes the device an ideal
choice for WLAN (802.11 b/g) and Bluetooth® applications in the
2.4 to 2.5 GHz frequency range.
The SKY13385-460LF SP3T switch is provided in a compact Quad
Flat No-Lead (QFN) 2 x 2 mm package. A functional block
diagram is shown in Figure 1. The pin configuration and package
are shown in Figure 2. Signal pin assignments and functional pin
descriptions are provided in Table 1.
J1
4
J2
RFC
S1812
Figure 2. SKY13385-460LF Pinout
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201513D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 18, 2015
1
DATA SHEET • SKY13385-460LF SP3T SWITCH
Table 1. SKY13385-460LF Signal Descriptions (Note 1)
Pin
1
Name
J1
Description
Pin
RF port 1.
7
Name
VDD
Description
DC power supply.
2
GND
Ground
8
GND
Ground
3
J3
RF port 3.
9
J2
RF port 2.
4
V1
DC control voltage 1. See Table 4.
10
GND
Ground
5
V2
DC control voltage 2. See Table 4.
11
RFC
RF common (antenna) port.
6
V3
DC control voltage 3. See Table 4.
12
GND
Ground
Note 1: Exposed pad must be grounded.
Functional Description
The SKY13385-460LF includes an internal negative voltage
generator and decoder that eliminate the need for external DC
blocking capacitors on the RF ports. No external components are
required for proper operation. DC decoupling capacitors may be
added on the VDD and control lines if necessary.
Switching is controlled by three control voltage inputs: V1, V2, and
V3. Depending on the logic voltage level applied to the control
pins, the RFC (RF common) pin is connected to one of three
switched RF outputs (J1, J2, or J3) through a low insertion path,
while the path between the RFC pin and the other RF pins is in a
high isolation state. There is a fourth switching state that enables
J2 and J3 at the same time. The output power measured at J2
and J3 in this state is 3 dB less than the insertion loss.
For proper switching operation, the SKY13385-460LF must be set
to a state for a minimum of 10 μs before changing to a different
state. A typical switching diagram is shown in Figure 3.
Shutdown mode is enabled by connecting all control pins to logic
low. This mode reduces the overall current consumption of the
device to 5 μA, typical. To prevent the switch from accidentally
entering shutdown mode during switching, caution must be taken
to avoid having all three control signals (V1, V2, and V3) set to
logic low for more than 500 ns. When exiting shutdown mode, the
switch has a 25 μs startup time before switching occurs.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13385-460LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
The state of the SKY13385-460LF is determined by the logic
provided in Table 4.
Typical performance characteristics of the SKY13385-460LF are
illustrated in Figures 4 through 7.
Table 2. SKY13385-460LF Absolute Maximum Ratings (Note 1)
Parameter
Minimum
Maximum
Units
VDD
2.5
5.5
V
Control voltage (V1, V2, V3) (Note 2)
VCTL
1.65
3.50
V
Input power
PIN
+35
dBm
Storage temperature
TSTG
–40
+125
C
Operating temperature
TOP
–40
+85
C
Electrostatic Discharge: Human Body Model
(HBM), Class 1B
ESD
500
V
Supply voltage (VDD)
Symbol
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
Note 2: Any bias voltage applied to the V1, V2, or V3 pins may damage the device if there is no bias voltage also present on the VDD pin. Maximum control voltage cannot exceed VDD.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
September 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513D
DATA SHEET • SKY13385-460LF SP3T SWITCH
V1 (J1 Path)
V2 (J2 Path)
Min Time = 10 µs
V3 (J3 Path)
One Arm “On”
V1 (J1 Path)
V2 (J2 Path)
Min Time = 10 µs
V3 (J3 Path)
Two Arms “On”
To Avoid Shutdown
V1 = V2 = V3 = 0 < 500 ns
V1 (J1 Path)
To avoid putting the switch
into shutdown mode, the
three controls cannot be
logic low for more than
500 ns
Tmax = 500 ns
V2 (J2 Path)
V3 (J3 Path)
S2404
Figure 3. Typical Switching Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201513D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 18, 2015
3
DATA SHEET • SKY13385-460LF SP3T SWITCH
Table 3. SKY13385-460LF Electrical Specifications (Note 1)
(VDD = 2.5 V to 5.5 V, VCTL = 0 V (Low), VCTL = 1.8 V (High), TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless
Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
f = 1 GHz, RFC-J1, RFC-J2
0.40
0.50
dB
f = 1 GHz, RFC-J3
0.45
0.50
dB
f = 2 GHz, RFC-J1, RFC-J2
0.40
0.50
dB
f = 2 GHz, RFC-J3
0.47
0.55
dB
f = 2.4 to 2.5 GHz, RFC-J1, RFC-J2
0.43
0.55
dB
f = 2.4 to 2.5 GHz, RFC-J3
0.52
0.65
dB
RF Specifications
Insertion loss
IL
Insertion loss
IL
Insertion loss
IL
Isolation
Iso
f = 1 GHz, RFC-J1, RFC-J2, RFC-J3
40
43
dB
Isolation
Iso
f = 2 GHz, RFC-J1, RFC-J2, RFC-J3
34
37
dB
Isolation
Iso
f = 2.4 to 2.5 GHz, RFC-J1, RFC-J2,
RFC-J3
32
35
dB
Return loss
|S11|
f = 2.45 GHz
18
20
dB
Third order input intercept point
IIP3
f = 2.45 GHz,ΔF = 1 MHz,
PIN = +20 dBm/tone
+55
+57
dBm
+32.5
+30.5
dBm
dBm
Input 0.1 dB compression point
P0.1dB
f = 2.45 GHz:
RFC to J1 and J2
RFC to J3
2nd harmonic
2fo
f = 2.45 GHz, PIN = +20 dBm
+75
dBc
3rd harmonic
3fo
f = 2.45 GHz, PIN = +20 dBm
+75
dBc
Error vector magnitude, WLAN
EVM_WLAN
PIN for 2.5% error, WLAN 2.45 GHz,
802.11g, OFDM, 54 Mbps, 64 QAM
+27
dBm
Switching rise time
10/90% RF
180
Switching fall time
90/10% RF
110
130
ns
Switching on time
50% VCTL to 10/90% RF
250
500
ns
190
210
Switching off time
50% VCTL to 90/10% RF
Logic dwell time (Note 2)
TOP = –40 °C to +85 °C
Startup time (Note 3)
Shutdown state to any RF switch state
10
200
ns
ns
μs
12
20
25
μs
1.800
3.465
0.40
V
V
5.5
V
DC Specifications
Control voltage (Note 4):
High
Low
VCTL_HIGH
VCTL_LOW
Supply voltage
VDD
Supply current
IDD
VDD = 3.5 V
30
μA
Control current
ICTL
V1 = V2 = V3 = 1.8 V
2
μA
Shutdown mode supply current
IOFF
VDD = 3.5 V,
V1 = V2 = V3 = 0 V
5
μA
1.650
0
2.5
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Dwell time refers to the amount of time the switch is required to stay in any one state before switching to another state. Refer to the Functional Description section for more
information.
Note 3: Startup time refers to the amount of time it takes for the switch to be fully operational when coming out of shutdown mode (V1 = V2 = V3 = logic 0).
Note 4: Control voltage must be less than or equal to VDD at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
September 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513D
DATA SHEET • SKY13385-460LF SP3T SWITCH
Table 4. SKY13385-460LF Truth Table
Note:
V1
V2
V3
State
0
0
0
Shutdown
1
0
0
RFC to J1
0
1
0
RFC to J2
0
0
1
RFC to J3
0
1
1
RFC to J2 and J3
1 = 1.650 to 3.465 V
0 = 0 to 0.4 V
Any state other than described in this Table places the switch into an undefined state.
Typical Performance Characteristics
(VDD = 2.5 V to 5.5 V, VCTL = 0 V (Low), VCTL = 1.8 V (High), TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless
Otherwise Noted)
0
–0.2
–10
–20
–0.3
Isolation (dB)
Insertion Loss (dB)
0
RFC to J1
RFC to J2
RFC to J3
–0.1
–0.4
–0.5
–0.6
–0.7
–30
–40
–50
–60
–0.8
RFC to J2
RFC to J3
–70
–0.9
–80
–1.0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
0
0.5
1.0
1.5
2.5
3.0
3.5
4.0
4.5
Figure 5. Typical Isolation vs Frequency
(RFC to J1 Insertion Loss State)
Figure 4. Typical Insertion Loss vs Frequency
0
0
–10
–10
–20
–20
–30
Isolation (dB)
Isolation (dB)
2.0
Frequency (GHz)
Frequency (GHz)
–40
–50
–60
–30
–40
–50
–60
RFC to J1
RFC to J3
–70
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Frequency (GHz)
Figure 6. Typical Isolation vs Frequency
(RFC to J2 Insertion Loss State)
4.0
RFC to J1
RFC to J2
–70
–80
4.5
–80
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
Frequency (GHz)
Figure 7. Typical Isolation vs Frequency
(RFC to J3 Insertion Loss State)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201513D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 18, 2015
5
DATA SHEET • SKY13385-460LF SP3T SWITCH
Evaluation Board Description
Package and Handling Information
The SKY13385-460LF Evaluation Board is used to test the
performance of the SKY13385-460LF SP3T Switch. The board is
made from a two-layer construction with ½ oz. copper cladding
on top and bottom. The first layer material is 12-mil Rogers
4003C. The second layer material is 49-mil of FR4 for a total
board thickness of about 62 mils. The impedance of all RF traces
is 50 Ω.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SKY13385-460LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
An Evaluation Board schematic diagram is provided in Figure 8.
An assembly drawing for the Evaluation Board is shown in
Figure 9.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Package Dimensions
The PCB layout footprint for the SKY13385-460LF is provided in
Figure 10. Typical part markings are shown in Figure 11. Package
dimensions for the 12-pin QFN are shown in Figure 12, and tape
and reel dimensions are provided in Figure 13.
Antenna
2
3
GND
J2
GND
GND
J3
VDD
V1
RF Port 3
J1
4
5
9
RF Port 2
8
7
DC Supply
V3
1
V2
RF Port 1
10
RFC
11
GND
12
6
DC Control
Voltage 1
DC Control
Voltage 3
DC Control
Voltage 2
S2392
Figure 8. SKY13385-460LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
September 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513D
DATA SHEET • SKY13385-460LF SP3T SWITCH
RFC
J1
J2
J3
GND
VDD
V3
V2
V1
6
GND
1
S2475
Figure 9. SKY13385-460LF Evaluation Board Assembly Diagram
Pin 12
12X 0.200
R0.2
Pin 1
0.50 Pitch
0.76
2X 0.380
12X 0.440
Exposed Soldering
Area
12X 0.710
All measurements in millimeters
S2393
Figure 10. SKY13385-460LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201513D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 18, 2015
7
DATA SHEET • SKY13385-460LF SP3T SWITCH
Pin 1
Indicator
Skyworks Part #
Figure 11. Typical Part Markings
(Top View)
Seating
Plane
–C–
2.00
0.76 +0.10/–0.15
–A–
(0.380)
0.02 +0.03/–0.02
–B–
Pin 1
Indicator
R0.20
Pin 1 Indicator
Detail A
Pin 1
2.00
0.76 +0.10/–0.15
(0.380)
0.05 C
2X
0.55 + 0.05/–0.04
2X
0.05 C
0.05 C
Top View
Exposed Pad
12X 0.25 Min.
12X 3
0.05 C
0.50
Side View
Bottom View
0.29 ± 0.075
0.2 ± 0.05
Notes:
4
0.10 M C A B
1.
2.
3.
4.
All measurements are in millimeters.
Dimensions and tolerances according to ASME Y14.5M-1994.
Coplanarity applies to the terminals and all other bottom surface metallization.
Dimension applies to metallized terminal. If the terminal has a radius on its end,
the width dimension should not be measured in that radius area.
Detail A
Scale: 100X
12 Places
Figure 12. SKY13385-460LF 12-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
September 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513D
S2198
DATA SHEET • SKY13385-460LF SP3T SWITCH
2.00 ± 0.05
Ø1.50 + 0.10/–0.00
4.00 ± 0.10
7º
1.75 ± 0.10
Pin 1
0.23 ± 0.05
A
2.25 ± 0.05
3.50 ± 0.05
8.00 ± 0.20
0.70 ± 0.05 (Ko)
Section A
B
4.00 ± 0.10
A
B
7º
2.25 ± 0.05
Section B
Notes:
1.
2.
3.
4.
5.
Carrier tape must meet all requirements of Skyworks GP01-D232 procurement spec for tape and reel shipping.
Carrier tape shall be black conductive polycarbonate bakeable material at 125 ˚C temperature.
Cover tape shall be transparent conductive with 5.40 mm width.
ESD-surface resistivity must meet all ESD requirements of Skyworks specified on GP01-D232.
All measurements are in millimeters.
ts737
Figure 13. SKY13385-460LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201513D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 18, 2015
9
DATA SHEET • SKY13385-460LF SP3T SWITCH
Ordering Information
Model Name
SKY13385-460LF SP3T Switch
Manufacturing Part Number
SKY13385-460LF
Evaluation Board Part Number
SKY13385-460LF-EVB
Copyright © 2011-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
September 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201513D