4 3 2 1 REVISIONS THIS DRAWING AND THE INFORMATION CONTAINED WITHIN IT ARE CONFIDENTIAL AND MAY NOT BE COPIED OR DISCLOSED WITHOUT THE WRITTEN PERMISSION OF TERRA POWER SYSTEMS. ZONE REV. DESCRIPTION DATE APPROVED 1 PRODUCTION RELEASE 11/05/2010 J. KAUFMAN 165±1 4X 13 C'BORE FOR M6 OR 1/4" SCREW HEAD 124±0.75 D D 12X #8-32x5/16" STAINLESS PPH SCREW W/ EXT TOOTH LOCK WASHER 129±0.75 107±0.75 8X M8x1.25 STAINLESS FLANGE NUT NEGATIVE RETURN BUS BAR C 8X 15±0.75 4X THROUGH HOLES FOR M6 OR 1/4" PAN HEAD SCREWS 47.50±1 2X SPARE ATO SCREW POSITIONS C 2X SPARE ATC/ATO FUSE POSITIONS (#8 SCREW-DOWN) ATO/ATC - A MAX 10 AWG ATO/ATC - F MAX 10 AWG MAX 4/0 CABLE B B MAX 4/0 CABLE MAX 2/0 CABLE MAX 4/0 CABLE 2X SPARE MIDI FUSE POSITIONS A 4X SPARE MIDI SCREW POSITIONS COVER ASSEMBLY OPTIONAL ATO/ATC FUSE PULLER MIDI #1 MAX 2/0 MIDI #2 MAX 2/0 MIDI #3 MAX 2/0 8X M5-0.8 X10mm STAINLESS PAN HEAD SCREWS W/ HI-TEMP NYLON PATCH MIDI #4 MAX 2/0 VIEW SHOWN WITHOUT COVER ASSEMBLY FOR CLARITY DIMENSIONS ARE SHOWN IN MILLIMETERS. UNSPECIFIED TOLERANCES ARE: ANGLES ±0°30' MATERIAL THIRD ANGLE PROJECTION *** CONSULT FACTORY FOR CUSTOM FUSE LOADING VARIATIONS 4 3 2 FINISH MM .000±.051 .00±.127 .0±.254 --- DO NOT SCALE DRAWING A NAME DATE DRAWN J. KAUFMAN 11/05/2010 CHECKED - - - - - - - - - - - COMMENTS: - 425 Sequoia Drive Bellingham, WA 98226 Phone (360)738-9010 Fax (360)738-0372 PDM LX SERIES OUTLINE DRAWING PART NUMBER: 880089 SIZE DWG. NO. C SCALE 1:1 WEIGHT: - 1 REV. 880089 1 SHEET 1 OF 1