4 D 3 2 1 REVISIONS NOTES: 1. DRAWING SHOWN WITH FUSES INSTALLED, REFER TO CHART FOR DETAILS 2. ALL STUDS TO BE STAINLESS STEEL WITH ROLLED THREADS 3. ALL BUS BARS TO BE TIN PLATED COPPER 4. WEIGHT EST 350 grams 5. RECOMMENDED TORQUE VALUES: 1. MEGA FUSES - 15 N-m ±1.36 (11 ft-lb ±1) 2. TERMINALS - 28.5 N-m ±1.36 (21 ft-lb ±1) 6. COVER LABEL (SEE CHART) PLACED ON OUTSIDE OF COVER 7. RECOMMENDED HARDWARE (TO BE INSTALLED AT LESS THAN 300 RPM); 1. M10x1.50 18-8 STAINLESS STEEL 2. M8x1.25 18-8 STAINLESS STEEl 8. LOCATION OF GORE VENT 9. MATERIAL: HOUSING: GLASS FILLED NYLON 94V-0 COVER: GLASS FILLED PC 94V-0 10. MIN/MAX TEMPERATURE RATING: OPESRATIONAL: -50C~105C NON-OPERATIONAL: -55C~125C 11. MAX CURRENT INPUT: 600 AMPS 12. MAX ASSEMBLY TORQUE (PRODUCT TO MOUNTING SURFACE): 30 N-m ZONE REV. DESCRIPTION DATE APPROVED A PER EC510604: INITIAL RELEASE 6/4/2014 J LIU D 4X 7.2 128.3 MEGA FUSE-A 7.1 7.1 6 MEGA FUSE-B 124.8 C 2X 8.50±0.1 MOUNTING HOLES FOR M8 HARDWARE C 58.97±0.2 7.2 7.1 INSIDE FUSE COVER FUSE COVER REMOVED 105±0.5 3X 41.16±1 45 20.70±1 B B A 1 LITTELFUSE FUSE A P/N FUSE B P/N P/N MUST BE MOUNTED ON FLAT, EVEN SURFACE 880195100 0298250.ZXEH 0298150.ZXEH 880195200 0298200.ZXEH 0298200.ZXEH 880195300 0298250.ZXEH 0298250.ZXEH 880195400 N/A 880195500 N/A 0298100.ZXEH 0298100.ZXEH 8 A A NAME ( 3.15) X8 TYP DATE DIMENSIONS ARE IN MM. DRAWN J. LIU DIMENSIONS AND TOLERANCES ARE DEFINED ACCORDING TO ANSI / ASME Y14.5M-1994 CHECKED - - - - - - - - - - - THIS DRAWING AND THE INFORMATION CONTAINED WITHIN IT ARE CONFIDENTIAL AND MAY NOT BE COPIED OR DISCLOSED WITHOUT THE WRITTEN PERMISSION OF LITTELFUSE. 6/4/2014 425 Sequoia Drive Bellingham, WA 98226 Phone (360)738-9010 Fax (360)738-0372 POWER PDM 2 POSITION W- GASKET THIRD ANGLE PROJECTION SIZE DWG. NO. C SCALE 2:3 4 3 2 REV. OL-880195000 A SHEET 1 OF 1 1