4 3 2 1 REVISIONS ZONE NOTES: 1. DRAWING SHOWN WITH FUSES INSTALLED, FUSE LOADING CONFIGURATION DEPENDANT D 2. ALL STUDS TO BE STAINLESS STEEL WITH ROLLED THREADS 3. ALL BUS BARS TO BE TIN PLATED COPPER 4. WEIGHT: 0.86 LB 5. 6. C REV. DESCRIPTION DATE APPROVED A PER EC#510230: INITIAL RELEASE 3/5/2014 J. KAUFMAN D RECCOMENDED TORQUE VALUES: 1. MIDI FUSES - 3 N-m(27 IN-LB) 2. RECOMMENDED INPUT TERMINAL STUD NUT TORQUE - 20 N-m(15 FT-LB) 3. RECOMMENDED OUTPUT TERMINAL STUD NUT TORQUE - 20 N-m(15 FT-LB) DRAWING SHOWN WITHOUT OPTIONAL LABEL, LABEL LOCATED ON OUTSIDE OF COVER 7. INCLUDED HARDWARE (TO BE INSTALLED AT LESS THAN 300 RPM); 4. M8x1.25 18-8 STAINLESS STEEL 4X 8. CONNECTOR HOUSING: FCI APEX 2.8MM FEMALE 4-WAY FCI P/N: 54200409 9. MATERIAL: HOUSING: GLASS FILLED NYLON 94V-0 10. MIN/MAX TEMPERATURE RATING: OPESRATIONAL: -40C~100C NON-OPERATIONAL: -55C~125C 11. MAX CURRENT INPUT: 350 AMPS 66.2±0.5 COVER: PC 94V-0 C 7 146±1 123.83±0.75 8 9±0.25 MOUNTING HOLE FOR M8 (5/16") HARDWARE 2X ATO FUSE LOCATIONS "A"-"D" SPARE SCREWS X2 BATTERY INPUT MAX 4/0 LATCH 2X MIDI FUSE LOCATIONS #1- #3 INSIDE FUSE COVER B 11.11±0.25 10.9±0.25 71.44±0.75 99.08±0.5 100.16±0.75 MIDI #1 MAX 2/0 MIDI #2 MAX 2/0 MIDI #3 MAX 2/0 B BREAK OUT WALL FOR SIDE CABLE ENTRY 42.58±1 FUSE COVER NOT SHOWN TETHER PART NUMBER FUSE A PN FUSE B PN FUSE C PN FUSE D PN FUSE 1 PN FUSE 2 PN FUSE 3 PN 880073100 0287010.PXS 0287015.PXS 0287020.PXS 0287020.PXS 0498050.M 0498030.M 0498030.M A NAME DATE DIMENSIONS ARE IN MM. DRAWN J. LIU DIMENSIONS AND TOLERANCES ARE DEFINED ACCORDING TO ANSI / ASME Y14.5M-1994 CHECKED - - - - - - - - - - - THIS DRAWING AND THE INFORMATION CONTAINED WITHIN IT ARE CONFIDENTIAL AND MAY NOT BE COPIED OR DISCLOSED WITHOUT THE WRITTEN PERMISSION OF LITTELFUSE. 3/5/2014 425 Sequoia Drive Bellingham, WA 98226 Phone (360)738-9010 Fax (360)738-0372 PDM XT Series THIRD ANGLE PROJECTION SIZE DWG. NO. C SCALE 1:2 4 3 2 OL-880073000 SHEET 1 OF 1 1 REV. A A