Pulsar R96 ExnA

1
2
TYPE EXAMINATION CERTIFICATE
Equipment or Protective systems intended for use in Potentially
Explosive Atmospheres - Directive 94/9/EC
3
Type Examination Certificate No:
FM15ATEX0059X
4
Equipment or protective system:
(Type Reference and Name)
R96 Pulsar Radar level Transmitter/Pulsar Radar Level
Probe
5
Name of Applicant:
Magnetrol International Inc.
6
Address of Applicant:
705 Enterprise Street
Aurora, IL 60504 USA
7
This equipment or protective system and any acceptable variation thereto is specified in the schedule to this
certificate and documents therein referred to.
8
FM Approvals Ltd. certifies that this equipment has been found to comply with the Essential Health and
Safety Requirements relating to the design and construction of equipment intended for use in potentially
explosive atmospheres given in Annex II to the Directive.
The examination and test results are recorded in confidential report number:
3054552 dated 22nd January 2015
9
Compliance with the Essential Health and Safety Requirements, with the exception of those identified in
item 15 of the schedule to this certificate, has been assessed by compliance with the following documents:
EN 60079-0:2012 + A11:2013, EN 60079-15:2010 and EN 60529:2002
10
If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to specific
conditions of use specified in the schedule to this certificate.
11
This Type Examination certificate relates only to the design, examination and tests of the specified
equipment or protective system in accordance to the directive 94/9/EC. Further requirements of the Directive
apply to the manufacturing process and supply of this equipment or protective system. These are not
covered by this certificate.
12
The marking of the equipment or protective system shall include:
II 3 G Ex nA IIC T4…T1 Gc Ta = -15ºC to +70ºC; IP67
II 3 G Ex ic IIC T4…T1 Gc Ta = -15ºC to +70ºC; IP67
cn=Mick Gower, o=FM Approvals,
ou,
email=mick.gower@fmapprovals.
com, c=GB
2016.02.03 11:44:34 Z
Mick Gower
Certification Manager, FM Approvals Ltd.
Issue date: 03rd February 2016
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 029 (Apr/14)
Page 1 of 3
SCHEDULE
to Type Examination Certificate No. FM15ATEX0059X
13
Description of Equipment or Protective System:
The Pulsar Model R96 is a 24VDC loop powered, non-contact radar level transmitter, for liquid level control
utilizing the engineering principle of pulse burst radar technology. The primary components are the probe
assembly, and Preamp PC Board assembly, and the electronics assembly containing all other PC Boards.
Short bursts of 6GHz microwave energy is emitted and subsequently reflected from the liquid level surface.
Distance is calculated by the equation D= Transit time (round trip)/2. Liquid level is then calculated by
applying the tank height value.
The Pulsar Model R96 is housed in a dual compartment (die-cast aluminum or investment cast 316SS)
enclosure with separate wiring and electronics compartments. The wiring compartment at the top of the
transmitter isolates the power/signal conductors from the electronics compartment beneath it by way of an
environmentally sealed feed-through. A probe coupling eases installation and allows probes to be installed
without concern for their orientation to the transmitter head.
Model Code Structure:
R96-5abc-def-RAg-hij-k00. Pulsar R96 Radar Level Transmitter / Pulsar Radar Level Probe.
a = Signal Out: 1 or 2.
b = Options: 0 or 1.
c = Accessories: 0 or A.
d = Classification: 1, 3 (when a = 1 or 2), 0, A, B or C.
e = Housing/Conduit Connection: 1 or 2.
f = Options: 0, 2 or 3.
g = Configuration Style: A, B, C, 3, 4, or 6.
h = Material of Construction. Antenna/ Mounting Nut: A, B, C, G, L or K.
i = Process Connection Size Type: 31, 32, 43, 44, 45, 53, 54, 55, 63, 64, 65, 73, 74, 75, 83, 84, 85, DA, DB, DD,
EA, EB, ED, FA, FB, FD, GA, GB, GD, HA, HB, HD, 3P, 4P, 5P, 6P or 7P.
j = O rings: 0, 1, 2 or 8.
k = Maximum Nozzle Length: 0, 1, 2 or 3.
14
Specific Conditions of Use:
1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or
friction. Care must be taken during installation and use to prevent impact or friction.
2. To maintain the T4 to T1 temperature code care shall be taken to ensure the “Enclosure Temperature”
does not exceed 70ºC
3. The risk of electrostatic discharge shall be minimized at installation, following the direction given in the
instruction.
4. For Installation with ambient temperature of 70ºC, refer to the manufacturer’s instructions for guidance on
proper selection of conductors.
5. Provisions shall be made to provide transient overvoltage protection to a level not to exceed 119Vdc.
6. The sensor probes maintain a category 1G rating.
7. Temperature codes for the ratings Ex nA IIC and Ex ic IIC are defined by the following table::Process
From 0°C to 110°C
From 110°C to 175°C
From 175°C to 275°C
From 275°C to 425°C
Temperature Code-TCG
T4
T3
T2
T1
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 029 (Apr/14)
Page 2 of 3
SCHEDULE
to Type Examination Certificate No. FM15ATEX0059X
15
Essential Health and Safety Requirements:
The relevant EHSRs that have not been addressed by the standards listed in this certificate have been identified
and assessed in the confidential report identified in item 8.
16
Test and Assessment Procedure and Conditions:
This Type Examination Certificate is the result of testing of a sample of the product submitted, in
accordance with the provisions of the relevant specific standard(s), and assessment of supporting
documentation. It does not imply an assessment of the whole production.
Whilst this certificate may be used in support of a manufacturer’s claim for CE Marking, FM Approvals Ltd
accepts no responsibility for the compliance of the equipment against all applicable Directives in all
applications.
This Certificate has been issued in accordance with FM Approvals Ltd’s ATEX Certification Scheme.
17
Schedule Drawings
A list of the significant parts of the technical documentation is annexed to this certificate and a copy has
been kept by FM Approvals Ltd.
18
Certificate History
Details of the supplements to this certificate are described below:
Date
Description
03rd February 2016
Original Issue.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals Ltd. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS
T: +44 (0) 1753 750 000 F: +44 (0) 1753 868 700 E-mail: [email protected] www.fmapprovals.com
F ATEX 029 (Apr/14)
Page 3 of 3
Blueprint Report
Magnetrol International Inc (1000000020)
Class No
3615
Original Project I.D.
Certificate I.D.
3054552
FM15ATEX0059X
Drawing No.
Revision Level
Drawing Title
Last Report
Electronic Drawing
005-8096
L
Pulsar R96
3054552
Yes (pdf)
030-3623
D
PULSAR 2 6 GHz ANALOG BOARD
3054552
Yes (pdf)
030-9159
S
Hart Digital P.C. Board
3054552
Yes (pdf)
030-9162
B
DISPLAY P.C. BOARD
3054552
Yes (pdf)
030-9164
F
Foundation Fieldbus Digital PC Board
3054552
Yes (pdf)
030-9165
F
WIRING BOARD
3054552
Yes (pdf)
030-9166
D
FOUNDATION FIELDBUS WIRING BOARD
3054552
Yes (pdf)
031-2850
C
DISPLAY MODULE ASSY
3054552
Yes (pdf)
031-2890
A
POTTED MODULE ASSEMBLY (MODEL R96)
3054552
Yes (pdf)
070-2004
D
Catalyst
3054552
Yes (pdf)
070-2005
E
Epoxy Cement
3054552
Yes (pdf)
070-2015
C
UR 3001 HP2 CLEAR
3054552
Yes (pdf)
091-1313
G
Silastic RTV 732
3054552
Yes (pdf)
094-6067
L
ECLIPSE 4X DIGITAL BOARD
3054552
Yes (pdf)
094-6069
B
Schematic Pulsar 2X Analog Board 6 GHZ (R96)
3054552
Yes (pdf)
094-6070
B
Display Board "Eclipse 706"
3054552
Yes (pdf)
094-6072
D
Digital Board Foundation Fieldbus
3054552
Yes (pdf)
094-6073
D
Wiring Board "Eclipse 706"
3054552
Yes (pdf)
094-6075
D
Foundation Fieldbus Wiring Board "Eclipse 706"
3054552
Yes (pdf)
099-5061
B
System Drawing Model R95 Radar Transmitter
3054552
Yes (pdf)
099-6559
D
Model R96 Through Air Radar
3054552
Yes (pdf)
58-602
11/11/15
Pulsar R96 Radar
3054552
Yes (pdf)
03/02/2016