I. General & Electrical Requirements
1.
Note 1
Tuned Center Frequency Range (FCOM)
:
FMIN = 90MHz to FMAX = 512MHz in 500 steps
2. Passband @ 3dB: ±2.5% minimum
3. Passband Insertion Loss: < 5.0dB
4. Passband Variation (FSIG ±1.5%, peak-valley): < 1.5dB
5. FTUNE VSWR (within the FSIG Passband into 50Ω): < 2.0:1
6. Absolute Stop Band Attenuation:
FSIG ±10%: 16 dB minimum
2x FSIG to < 750MHz: 35dB minimum
FSIG ±20%: 27 dB minimum
750MHz to 1.2GHz: 25dB minimum
30MHz to ½ FSIG: 38dB minimum
1.2GHz to 2.0GHz: 15dB minimum
rd
7. In-band 3 Order Intercept: +40dBm minimum
2 tones at FTUNE ±0.5%, +24dBm/tone
8. In Band RF Power Handling: ≤ 2.0-watts CW
9. Out of Band Power Handling: 5-watts CW, > FTUNE ±10%
10. ZIN/ZOUT: 50Ω nominal
11. Tuning Method:
Digital Control: 500-steps (501 frequencies), 8-bit parallel control
Band-0, 90.54MHz to 225MHz: FSTEP = 0.54MHz
Band-1, 226.148MHz to 512MHz, FSTEP = 1.148MHz
Tuning Speed (+10dBm reference): < 20µsec
Tuning Speed is defined from second rising edge of STROBE to 90% steady state RF voltage.
12. DC Power:
VCCA: +5VDC ±10%
ICCA: < 320mA
VCCD: +3.3VDC ±10%
ICCD: < 30µA
Vbb: +200VDC ±10%
Ibb: < 5mA
Note 1:
FSIG = Frequency of the signal,
FCOM is the target command frequency that the filter will be directed to.
FCOM = Integer ((FSIG- FMIN)/ FSTEP)* FSTEP + FMIN
Note 2:
Vbb= +200V, the filter command frequencies are set up with +200V applied.
Vbb = +100V (Ibb = 5mA), Power handling reduces to 1.25-watt.
II. Environmental & Physical Requirements
1.
2.
Temperature Range:
Operating: -30°C to +75°C
Storage: -40°C to +85°C
Package:
Style: SMT (ref. Figure 1)
Size: 2.000” ±0.005 (L) x 2.780” ±0.005 (W) x 0.495” maximum (H)
Materials:
Base: PCB
Cover: Silver Plated Brass per ASTM B 700
Termination Finish: Sn63Pb37 tinned
Page 1 of 3
MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without the express written permission of MtronPTI.
TF0113 Series Digitally Tunable LC Filters
90MHz – 512MHz
Figure 2: PCB PAD Layout
Figure 1: Package Outline Drawing
Pin-Out and Function
Pin #
Ref Des
1
Ser/Par
2
TR
3
VCCD
4
5
6
7
8
9
10
A7
A6
A5
A4
A3
A2
A1
Description
Tied to Ground on PCB
(always parallel mode)
Tune Ready Output
Digital Interface Supply
(+3.3VDC)
Tune Bit 7 (MSB)
Tune Bit 6
Tune Bit 5
Tune Bit 4
Tune Bit 3
Tune Bit 2
Tune Bit 1
Maximum Rating
Pin #
Ref Des
Description
N/A
11
A0 (LSB)
Tune Bit 0
VCCD + 0.5VDC
12
STB
Strobe
-0.5V to +3.63V
13
VCCA
+5VDC
VCCD + 0.5VDC
14
15
16 – 19
20
21 – 31
32
33 - 37
GND
Vbb
GND
RF
GND
RF
GND
Ground
High Bias (+200VDC)
Ground
RF In/Out Note 3
Ground
RF In/Out Note 3
Ground
Note 3: Maximum rating for RF input power shall be +33dBm (2.0-watts in-band CW) and +37dBm (5-watts out-of-band), > FTUNE ±10%, CW)
III. Interface Timing:
Page 2 of 3
MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without the express written permission of MtronPTI.
Maximum Rating
VCCD + 0.5VDC
-0.5V to +5.5V
+220VDC
+33dBm, +37dBm
+33dBm, +37dBm
TF0113 Series Digitally Tunable LC Filters
90MHz – 512MHz
IV. Interface Timing: (cont.)
When the STROBE goes HIGH, it activates the tuning process and the BAND BYTE would be stable and read available for
approximately 350ηsec, after which the STROBE will go LOW. This would be followed by an approximate 350ηsec wait period,
after which the STROBE will go HIGH to initiate the reading of the TUNE INDEX BYTE which would be stable and read available for
approximately 350ηsec, after which the STROBE will go LOW. The next TUNE process would follow no sooner than approximately
22µsec after the completion of the last TUNE and would be triggered when the STROBE goes High.
Band Byte
xxxx xx01
xxxx xx01
Frequency Index Byte
00000000
00000001
.
.
.
.
.
.
Frequency Index Byte (dec)
0
1
.
.
.
xxxx xx01
xxxx xx10
xxxx xx10
.
.
.
xxxx xx10
Tune Frequency
90.54 MHz
91.08 MHz
.
.
.
Band 2
Step Size = 0.54 MHz
11111001
00000000
00000001
249
0
1
225 MHz
226.148 MHz
227.36 MHz
.
.
.
.
.
.
.
.
.
11111001
249
512 MHz
V. Data Sheet Revision:
Date
05-06-15
Rev.
A
Author
DPD
Comments
Details of Revision
Original Release.
Page 3 of 3
MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without the express written permission of MtronPTI.
Band 3
Step Size = 1.148 MHz