TF0103 Digitally Tunable LC Filters 30MHz – 90MHz – typical performance I. General & Electrical Requirements Tuned Center Frequency Range (FCOM) Note 1: FMIN = 30MHz to FMAX = 90MHz in 250-steps, FSTEP = 240kHz 2. Passband @ 3dB: FSIG ±200kHz 3. Passband Insertion Loss: ≤ 3.6dB 4. Passband Variation (peak-valley): ≤ 0.3dB 5. Input/Output VSWR (within the FSIG Bandwidth into 50): < 2.0:1 6. Absolute Stop Band Attenuation: FSIG ±10%: 16dB minimum 1.6MHz to ½ FTUNE: 40dB minimum FSIG ±15%: 22dB minimum 2x FSIG to < 750MHz: 35dB minimum FSIG ±20%: 27dB minimum 750MHz to 1.2GHz: 25dB minimum 1.2GHz to 2.0GHz: 15dB minimum 7. In-Band IIP3: +45dBm minimum 8. In Band RF Power Handling: ≤ 1.25-watts (+31dBm) CW 9. Out of Band RF Power Handling: 5-watts (+37dBm) CW, ≥ ±10% from FTUNE 10. ZIN/ZOUT: 50 nominal 11. Tuning Method: Digital Control: 250-steps, 8-bit parallel Tuning Speed: < 25µsec 12. DC Power: V1: +5VDC ±5% I1: < 275mA V2: 100VDC ±5% Note 2 I2: 1.5mA typical 1. Note 1: FSIG = Frequency of the signal, Where; FCOM is the target command frequency that the filter will be directed to. FCOM = Integer((FSIG- FMIN)/ FSTEP)* FSTEP + FMIN Note 2: V2 = 100V, the filter command and tune frequencies are set up with 100V applied and the filter is fully compliant to these specification. For V2 = 50V (I2 = 1.5mA), the filter will be functional but the filter command frequency may have greater error. Power handling and linearity will be degraded. II. Environmental & Physical Requirements 1. Temperature Range: Operating: -40°C to +85°C Storage: -45°C to +90°C 2. Package Size: 2.300” (L) x 1.100: (W) x 0.600” (H) Style: 42-pin thru-hole Page 1 of 2 MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI. TF0103 Digitally Tunable LC Filters 30MHz – 90MHz – typical performance III. Interface Timing: IV. Data Sheet Revision: Date 06/25/13 Rev. - Author BRM Details of Revision Original Draft. Page 2 of 2 MtronPTI - 2525 Shader Road - Orlando - Florida - 32804 - USA - 1-407-298-2000 - www.mtronpti.com The information contained herein is proprietary to MtronPTI and is submitted in confidence. This information may not be copied or divulged without the express written permission of MtronPTI.