25kW X-Band Magnetron
M1311L is a fixed frequency pulsed type X-band magnetron, designed to
operate in the frequency range of 9345 to 9405 MHz with a peak output
power of 25 kW. It is wavequide output type and forced air cooled.
It is recommended to use our TL393 or TL368A as adequate protector for
this magnetron.
---- ELECTRICAL ---Min
Typical
Max
Unit
Heater Voltage(Preheat) ········· 5.7
6.3
6.9
V
Heater Voltage(Operation) ······· 3.7(NOTE1)
V
Preheat time····················· 120
S
Peak anode voltage ·············· 7.5
8.0
8.5
kV
Rate of rise of voltage pulse ··· 70
100
kV/µs
Peak anode current ·············· 6.0
8.0
10.0
A
Mean anode current ·············· 6.0
8.0
10.0
mA
Peak anode input power ·········· 75
kW
Mean anode input power ·········· 85
W
Pulse duration ·················· 0.05
1.0
1.0
µs
Duty Cycle ······················· 0.001
V.S.W.R at the output coupler ··· 1.15
1.5
Peak output power ·············· 22.5
25
kW
Frequency ······················ 9345
9375
9405
MHz
(NOTE1) Heater Voltage (Operation)=0.08(110-Pi)
Pi:Mean anode input power
---- MECHANICAL ---Overall dimensions ·············· SEE outline
Net weight ······················ 1.6kg approx
Output coupling ················· UG-40 B/U
New JRC could be available to customer’s desire for frequency lead and
connector. For further information on it and the use of the magnetron
please contact New JRC. New JRC reserves the right to change the
specification of goods without notice.