M1437(A)

M1437(A)
25kW X-Band Magnetron
M1437(A) is a fixed frequency pulsed type X-band magnetron, designed
to operate in the frequency range of 9380 to 9440 MHz with a peak output
power of 25 kW. It is wavequide output type and forced air cooled or
natural air cooled.
It is recommended to use our TL393 or TL368A as adequate protector for
this magnetron.
---- ELECTRICAL ---Min
Typical
Max
Unit
Heater Voltage(Preheat) ········· 5.7
6.3
6.9
V
Heater Voltage(Operation) ······· 3.7(NOTE1)
V
Preheat time····················· 120
S
Peak anode voltage ·············· 7.5
8.0
8.5
kV
Rate of rise of voltage pulse ··· 70
100
kV/µs
Peak anode current ·············· 6.0
8.0
10.0
A
Mean anode current ·············· 6.0
8.0
10.0
mA
Peak anode input power ·········· 75
kW
Mean anode input power ·········· 85
W
Pulse duration (Ditected R.F) ··· 0.05
1.0
1.0
µs
Duty Cycle ······················
0.001
V.S.W.R at the output coupler ··· 1.15
1.5
Peak output power ·············· 22.5
25
kW
Frequency ······················ 9380
9410
9440
MHz
(NOTE1) Heater Voltage (Operation)=0.08(110-Pi)
Pi:Mean anode input power
---- MECHANICAL ---Overall dimensions ·············· SEE outline
Net weight ······················ 1.6kg approx.
Output coupling ················· UG-40 B/U
New JRC could be available to customer’s desire for frequency, lead
and connector. For further information on it and the use of the magnetron
please contact New JRC. New JRC reserves the right to change the
specification of goods without notice.
97-9