Pressure measurement - Clamping force measurement with strain sensors - Reliable, permanent force measurement

Clamping force measurement with strain sensors
Reliable, permanent force measurement
Clamping force measurement with
strain sensors.
Monitoring, control, calibration.
Highlights
Your benefits
Monitoring and control
■
Quick and easy installation
■
Accuracy 1% FS (full scale)
Monitoring and control
■
Continuous monitoring
■
Verification of the clamping force
■
Recording of all measured values
via PC or machine control system
Calibration
■
Reliable and precise
■
Evaluation of the measured results
via USB with InspectMaster software
■
Independent of diameter
Calibration
■
Easy monitoring of clamping force,
parallelism and bending
■
Installation/measurement/evaluation
in a short time
■
Recording and evaluation of the
measured values via PC
Monitoring of clamping force – a crucial factor for compliance
with end product quality
Perfectly adjusted machines and tools, e.g. in presses and injection molding
machines, are essential to fulfill the high requirements on the end product quality.
This can be achieved through constant machine monitoring or periodic machine
calibration with Baumer tie bar sensors.
Regardless whether the measurements are made on or in the tie bar, the forces
during each work cycle are continually recorded.
Constant
clamping force
monitoring
DSRC strain rings
Easy installation, high measuring
accuracy. These benefits make the
strain ring a versatile measuring
instrument for monitoring tasks.
DSRH strain probes
The right solution in tight spaces.
Insert the strain probe in the hole,
apply tension, connect and the
measurement can start.
DABU AD2T amplifiers
The ideal amplifier for strain measurements. With its extremely low noise
and first-class signal processing, the
DABU AD2T is the ideal supplement
in the measuring chain with strain
sensors.
Machine protection
Calibration of machines
clamping force / parallelism /
bar bending
Calibration with strain clamps
and extensometers
DSRV strain clamps and DSRM extensometers can be quickly and easily
installed. The measured results are avail-­­
able quickly. With the extensometer
measurements are not only possible on
tie bars but also on plane surfaces.
The convincing measuring
chain!
The display box is the result of consistent development of the processing
electronic range from Baumer. Together
with the matching strain sensors, an
ideal measuring chain is formed.
Technical properties
Technical properties
measuring range ± 1000 με
characteristic curve deviation < 1% FS
2 x ¼ DMS bridge
DSRH strain probes
measuring range ± 1000 με
characteristic curve deviation < 1% FS
for cyclic applications
Ordering designations
Type
AX = axial cable outlet
BT = radial cable outlet
ST = plug outlet
QM = quick mount latch
Beam diameter (from 020…360 mm)
e.g. 060 = 60 mm
e.g. 150 = 150 mm
Metric/imperial
M = metric
Z = imperial
DSRC xx xxx x
DSRH x xx-xxxx x
Output
U = voltage output ±10 V
I = current output 4 - 20 mA
P = passive version with cable outlet
Bore diameter
12 = 12 mm
16 = 16 mm
20 = 20 mm
Length
0200 to 1400 mm
Metric/imperial
M = metric
Z = imperial
DSRV strain clamps
measuring range ± 1000 με
characteristic curve deviation < 1% FS
patented adjusting mechanism
variably adjustable
2 x ¼ DMS bridge
DDBF display box + InspectMaster analysis software incl. in the set
DSRM extensometers
DSRM M2M Measuring system with 2 sensors
measuring range ± 1000 με
DSRM M4M Measuring system with 4 sensors
characteristic curve deviation < 2% FS
DSRM M8M Measuring system with 8 sensors
magnetic holder
independent of diameter
full bridge
DDBF display box + InspectMaster analysis software incl. in the set
DDBF display boxes
freely configurable
including InspectMaster evaluation software (multilingual)
USB interface
DABx AD2T
bridge amplifiers
voltage or current output
very good noise characteristics
2 x ¼ bridge and full bridge
Sensors/measuring ranges 30-100
DSRV SET-SOL 170
1
DSRV SET-LEG 240
1
DSRV SET-MED 170
4
DSRV SET-MED 240
0
DSRV SET-COM 240
4
DSRV SET-RNG 100
4
DSRV SET-RNG 170
0
DSRV SET-RNG 240
0
100-170
1
1
4
4
4
0
4
0
170-240
0
1
0
4
4
0
0
4
DDBF 2-SC 2-channel, 2 x ¼ bridge
DDBF 4-SC 4-channel, 2 x ¼ bridge
DDBF 4-SM 4-channel, full bridge
DABx AD2T-xx xxxx
Output
U = voltage output
I = current output
DMS bridge
FB = full bridge
2Q = 2 x ¼ bridge
Gain
0,25 = 0,25 mV/V (Type FB)
0,50 = 0,50 mV/V (Type FB)
1,00 = 1,00 mV/V (Type FB)
2,00 = 2,00 mV/V (Type FB)
0250 = 250 με (Type 2Q)
0350 = 350 με (Type 2Q)
0500 = 500 με (Type 2Q)
1000 = 1000 με (Type 2Q)
Further details can be found at www.baumersensopress.com
Baumer Switzerland
Baumer United Kingdom
Baumer USA
Baumer Electric AG · P.O. Box
Hummelstrasse 17 · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122
Fax +41 (0)52 728 1144
[email protected]
www.baumerelectric.com
Baumer Ltd. · 33/36 Shrivenham Hundred Business Park
Watchfield · Swindon SN6 8TZ GB
Phone +44 (0)870 161 3000
Fax +44 (0)870 161 3030
[email protected]
www.baumergroup.com
Baumer Ltd. · 122 Spring Street, Unit C-6
US-Southington, CT 06489
Phone +1 (1)860 621-2121
Fax +1 (1)860 628-6280
[email protected]
www.baumerelectric.com
Technical modifications and errors reserved. Printed in Switzerland by Sonderegger Druck AG. 11/07 Nr. 802343
Product
DSRC strain rings