RENEWABLE ENERGY Circuit Breakers & Disconnects CATALOG • Rocker • Toggle • Pushbutton • Rotary CIRCUIT PROTECTION • Hydraulic-Magnetic • Thermal • GFCI / ELCI CUSTOM SOLUTIONS • PDU’s • Keypads • Control Modules STRATEGIC MARKETS SERVED: On/Off Highway Marine Telecom/Datacom Military Renewable Energy GLOBAL LOCATIONS: ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 COMPETITIVE ADVANTAGES + Vertical Integration Reliable & On-Time Delivery Excellent Customer Service MULTIPLEXED POWER SYSTEMS • HMI Devices & I/O Modules • Programmable Displays • Data Communication Interfaces • Electrical Systems Monitoring ..................................................................................................................... SWITCHES & CONTROLS ................... Since its founding, Carling Technologies has continually forged a tradition of leadership in quality and product innovation. ................... 1920 There are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With ISO and TS registered manufacturing facilities and technical sales offices worldwide, Carling ranks among the world’s largest manufacturers of circuit breakers, switches, power distribution units, digital switching systems and electronic controls. ................... FOUNDED IN Innovative & Eco-Friendly Products OTHER SERVED INDUSTRIES: Medical Industrial Control Audio / Visual Commercial Food HVAC Floor Care Generators Small Appliances Security Systems Test & Measurment WORLDWIDE NUMBERS: 2200+ 150+ EMPLOYEES ENGINEERS 70 + 50+ DISTRIBUTORS REP FIRMS Renewable Energy Circuit Breakers & Disconnects When you integrate Carling Technologies circuit breakers into your renewable energy generating systems, you are guaranteed maximum protection against harmful overcurrent. Further, Carling’s circuit breakers utilize the hydraulic/magnetic principal offering many advantages over other thermal magnetic circuit breakers and fuses currently available. In other words, using Carling Technologies circuit breakers protects not only the power system itself, but it also safeguards the structure where these systems are installed by eliminating the fire hazard that can be caused by overcurrent. Table of Contents page Product Selector Guide.......................................................2 CX-Series............................................................................... 3 C-Series............................................................................... 13 E-Series............................................................................... 34 F-Series................................................................................ 43 Time Delay Values.............................................................. 53 Within This Catalog, you will find comprehensive product information for each product series including applications, specifications and ordering schemes. Available Online are tools such as part configurator, product selectors and stock checks. For the latest information on all our products, please visit www.carlingtech.com Application Solution Engineers are readily available to assist you in selecting the appropriate product for your application. For further assistance, please email us at [email protected] Typical Photovoltaic System CX-SERIES C-SERIES E-SERIES F-SERIES Combiner Charge Controller DC DC In Out Main Disconnect F AC Breaker Panel H H N N G G AC Out Power Inverter AC In H N G H N G DC In Shunt Circuit Breaker Control Cable Meter www.carlingtech.com AC Generator Batter Bank 1000 Ah 1 Product Selector Guide CIRCUIT PROTECTION CX-Series C-Series E-Series F-Series Number of Poles 1-2, + auxiliary switch pole 1-6 (handle) 1-3 (rocker & metal toggle) 1-6 1-3 Actuator Style handle, 1 per pole sealed metal toggle handle rocker handle handle Available Delays DC: instant, ultrashort, short, medium & long AC, DC, AC/DC: instant, ultrashort, short, medium & long AC, DC: high inrush-short, medium & long AC, DC, AC/DC: instant, short, medium & long AC, DC, AC/DC: high inrushshort, medium & long AC, DC: short, medium & long Max Current & Voltage Ratings Max Interrupting Capacity UL Recognized 0.2-115A@600VDC UL Listed 0.2-15A@250/500VDC 0.2-50A@205/410VDC UL Listed and UL Recognized up to 10,000 amps UL Listed: 0.02-250A@80VDC 0.1-100A@125VDC 0.02-70A@120VAC 0.02-20A@240VAC UL Recognized: 0.02-30A@480WYE/277VAC 2 Pole, 1Ø; 3 Pole, 3Ø 0.02-50A@277VAC 0.02-100A@250VAC, 80VDC 0.02-100A@120V/ 240VAC, 65VDC UL Listed: 50000A@80VDC, 1P only 10000A@120VAC 5000A@125VDC/240VAC UL Recognized: 7500A@80VDC 3000A@125/250VAC, UL only 5000A@250VAC UL Listed 0.02-100A@240VAC, 80VDC, 125VDC UL Recognized 0.02-100A@277VAC, 160VDC, 1 pole 0.02-100A@600VAC, 2 Pole 1Ø, 3 pole 3Ø 0.02-120A@125VDC, 1 pole UL Listed 50000A@80VDC 10000A@125VDC & 240VAC-5KA UL Recognized 5000A@125VDC 5000A@600VAC, without fuse listed construction backup fuse backup with fuse backup 5000A@480WYE/277VAC with UL489 Listed: 50-250A@125VDC 100-250A@120/240VAC 100-250A@277VAC 100-250A@208Y/120, 3ØVAC UL489A Listed 250-700A@125VDC 50000A@125VDC 10000A@120/240, 277, 208Y/120VAC 10000A@600VAC, 20A@80VDC (GO circuit) 10.1A@250VAC 0.1A@125VAC (gold contacts) 0.5A@80VDC 10.1A@250VAC 1.0A@65VDC 0.1A@80VDC 10.1A@250VAC 0.5A@65VDC 0.1A@80VDC Available Circuits series trip series, shunt, relay, switch only, series with remote shutdown, relay & shunt trip dual coil, midtrip with alarm switch series, shunt,relay, switch only, series with remote shutdown series & switch only with or without metering shunt Terminal Options 10-32 or M5 screw terminals 1/4-20 or M6 threaded stud 10-32 stud, 1/4-20 stud, 10-32 screw with saddle clamp, 7/16 clip & push-In 10-32 stud, 1/4-20 stud, 0-32 screw, 1/4-20 screw, box wire connector 3/8-16 stud, 3/8-16 screw & box wire connector Mounting Method threaded insert: #6-32 UNC2B, or M3X0.5-6H B ISO (2 per pole) threaded inserts rear or front panel rear or front panel Agency Approvals UL489, UL1077, TUV (EN60934-2) UL, CSA, VDE, TUV, UL1500, UL489, UL489A UL, CSA, VDE, UL1500, UL489 cUL,TUV, UL489, UL489A Auxiliary Switch Rating *Options and approvals shown may apply to specific construction combinations only, consult factory for clarification. Manufacturer reserves the right to change product specifications without prior notice. 2 www.carlingtech.com CX-Series CX-Series Circuit Breaker - Introduction CX-Series CIRCUIT BREAKER The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: UL 489 & UL 489B Listed TUV Certified IEC/EN 60947-2 Temperature stable hydraulic-magnetic overcurrent sensing technology Optional relay trip circuit permitting remote operator system shut down Perfect fit for 380VDC Applications www.carlingtech.com 3 CX-Series Circuit Breaker - Design Features CX-Series DESIGN FEATURES HYDRAULIC/MAGNETIC SENSING COIL UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber 4 LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber MAGNETS ARC SPLITTER RETAINER with integrated pressurizing walls LARGE ARC GAP To generate high arc voltages (12) ARC DEIONIZING SPLITTER PLATES www.carlingtech.com CX-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION SERIES MAX CURRENT INTERRUPTING NUMBER RATING AMPS CAPACITY (AMPS) OF POLES MAX. RATING FREQUENCY 250 D.C. 15 5,000 1 250 / 500 D.C. 15 10,000 2 410 / 205 D.C. 50 10,000 2 Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE CIRCUIT CONFIGURATION MAX. RATING SERIES SWITCH ONLY1 MAX INTERRUPTING CURRENT CAPACITY (AMPS) FREQUENCY RATING AMPS NUMBER APPLICATION OF POLES CODE 300 D.C. 1 - 75 5,000 1 TC1, OL0, U3 300 D.C. 76 - 125 3,000 1 TC1, OL0, U3 440 D.C. 1 -30 10,000 2 TC1, OL0, U3 440 D.C. 31 - 63 5,000 2 TC1, OL0, U3 600 D.C. 1 - 75 5,000 2 TC1, OL0, U3 600 D.C. 76 - 115 3,000 2 TC1, OL0, U3 600 D.C. 1 - 115 ---- 2 or 3 --- Notes: 1 Requires inclusion of a relay trip voltage coil Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH VOLTAGE CIRCUIT CURRENT RATING INTERRUPTING CONFIGURATION MAX RATING FREQUENCY POLES (AMPS) RATING (AMPS) CONSTRUCTION NOTES 600 DC 21 50 - 100 600 May have a third pole that is a voltage trip pole 600 DC 42 110 - 175 600 May have a fifth pole that is a voltage trip pole SERIES Notes: 1 Two poles in series. 2 Two poles in series in parallel with 2 poles in series. Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switch gear and Control gear - Circuit Breakers CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR & CONTROL GEAR / CIRCUIT BREAKER VOLTAGE CIRCUIT CONFIGURATION SERIES MAX. RATING FREQUENCY POLES 440 DC 2 CURRENT RATING (AMPS) 1-63 INTERRUPTING CAPACITY ICS / ICU (AMPS) 4,000 *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 5 CX-Series Circuit Breaker - General Specifications Electrical Maximum Voltage Overload 600 VDC 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. RESISTANCEIMPEDANCE PER POLE VALUES RESISTANCE, VALUES fromfrom LineLine to Load Terminals to Load Terminals (ValuesBased Based on on Series Trip (Values Trip Circuit CircuitBreaker) Breaker) 1000 100 5.1-20.0 0.10 - 5.0 20.1-125 5.1 - 20.0 10 O H M S Current (amps) CURRENT 0.1(AMPS) -5.0 20.1 - 50.0 1 Tolerance (%) TOLERANCE 15% (%) 25% 15 25 35% 35 0.1 0.01 0.001 0.01 0.1 1 10 100-125 100 AMPERE RATING Physical Number of Poles Termination Terminals Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color 6 1- 2 poles, + Auxiliary Switch Pole. 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud Standard with multi-pole constructions Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Handle, 1 per pole. Series Trip Housing - Glass filled Polyester Handle - Glass filled Polyester Line/Load Terminals - Copper Alloy. ~150 Grams (~5.3 Ounces). ~150 Grams (~5.3 Ounces). Housing - Gray. Handle - White, Black, Red, Green, Blue, Yellow, Gray, Mechanical Endurance Max 10,000 ON-OFF operations @ 6 per minute; 6000 with rated current & voltage, and 4,000 cycles mechanical. Trip Free Trips on overload even when actuator is forcibly held in the “On” position. Trip Indication The operating handle moves positively to the “Off” position when an overload causes the breaker to trip. Environmental Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms saw tooth while carrying rated current per MILPRF-55629 and MIL-STD- 202G, Method 213G, Test Condition “I”. Instantaneous and ultra short curves tested at 90% of rated current Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, at rated current per MIL-PRF-55629 and MILSTD-202G, Method 240D, Test Cond. A. Instantaneous & ultrashort curves tested at 90% of rated current. MIL-PRF-55629 and MIL-STD- 202G, Method 106G, i.e., Ten 24- hour cycles at +25°C to +65°C, 80- 98% RH. Method 101, Condition A (90-95% RH at 5% NaCl Solution, 96 hrs). MIL-PRF-55629 and MIL-STD- 202G, Method 107G, Condition A (5-cycles at -55°C to +25°C to +85°C to +25°C). -40°C to +85°C. www.carlingtech.com CX-Series Circuit Breaker - UL489 – Ordering Scheme C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 615 6 Frequency & Delay 7 Current Rating 9 Actuator Color & Legend 10 Mounting Inserts 12 G 11 Rating 12 Agency Approval 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 5 Screw Terminal, M5 6 Stud, M6 1 SERIES C 2 ACTUATOR X Handle, one per pole 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 3 POLES 1 One 2 Two 4 CIRCUIT B Series Trip (current) 5 AUXILIARY/ALARM SWITCH 0 Without Aux Switch Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 11 MAX. APPLICATION RATING 12 250 VDC 13 250/500 VDC 1 15 205/410 VDC 7 CURRENT RATING (AMPERES) CODE 2 2 A 8 Terminal AMPERES 220 0.20 225 0.25 230 0.30 235 0.35 240 0.40 2450.45 250 0.50 255 0.55 260 0.60 265 0.65 270 0.70 275 0.75 280 0.80 285 0.85 290 0.90 295 410 512 415 517 420 522 425 527 430 435 440 445 450 455 0.95 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.50 4.00 4.50 5.00 5.50 www.carlingtech.com 460 465 470 475 480 485 490 495 610 710 611 711 612 712 613 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 12.50 13.00 614 14.00 615 15.00 616 16.00 61717.00 61818.00 62020.00 62222.00 62424.00 62525.00 63030.00 63535.00 64040.00 64545.00 65050.00 12 AGENCY APPROVAL A Without Approvals G UL 489 Listed S UL 489 Listed, TUV to IEC60947-2 1 Notes: 1 Only Available with 250/500 VDC up to 15 amps. 7 CX-Series Circuit Breaker - UL489B – Ordering Scheme C X 2 1 Series 2 Actuator 3 Poles S 0 4 Circuit 5 Relay Trip 1 SERIES C 2 ACTUATOR X Handle, one per pole 3 POLES 1,2 2 Two 3 Three 4 Four 5 Five 4 CIRCUIT S Switch Only 5 RELAY TRIP VOLTAGE COIL RATING 1,2 0 Without Relay Trip Voltage Coil A 12 VDC B 24 VDC C 32 VDC D 48 VDC 6 FREQUENCY & DELAY 03 DC Switch Only 7 CURRENT RATING (AMPERES) 1,3 2-Pole Section 810 50A - 100A 4-Pole Section 917 110A - 175A 8 03 810 6 Frequency & Delay 7 Current Rating 3 2 A 8 Terminal 9 Actuator Color & Legend 06 14 10 Mounting Inserts 11 Rating 12 Agency Approval 8 TERMINAL 4,5 3 Stud, 1/4-20 6 Stud, M6 A Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole B Stud, M6, with M5 Screw Terminals on Voltage Pole 9 HANDLE COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 10 MOUNTING INSERTS A 6-32 Thread B Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black M3 Thread 11 MAX. APPLICATION RATING 06 600VDC 12 AGENCY APPROVAL A Without Approvals 14 UL489B Listed Notes: 1 2 Pole Unit is required for ratings between 50A - 100A. 4 Pole Unit is required for ratings between 110A - 175A. 2 A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction. The addition of this extra pole dictates a change in the designation for the number of poles in selection 3. 3 For Current Ratings between 50A - 100A select current code 810 (100A). For Current Ratings between 101A - 175A select current code 917 (175A). 4 Voltage Pole must have screw terminals. Switch Pole must have stud terminals. 5 On 3 Pole Unit, Voltage Pole to be located at P1 as standard. On 5 Pole Unit, Voltage Pole to be located at P3 as standard. www.carlingtech.com CX-Series Circuit Breaker - UL1077 – Ordering Scheme C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 620 6 Frequency & Delay 7 Current Rating 2 ACTUATOR X Handle, one per pole 4 CIRCUIT Switch Only (no coil) 1, 9 A B Series Trip (current) Relay Trip (voltage) 1, 2, 3, 9 G 11 Rating 12 Agency Approval Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 11 MAX. APPLICATION RATING 10 300VDC 11 440 VDC without factory installed terminal bus 4 14 440VDC with factory installed terminal bus 4 06 600VDC 5 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 12 AGENCY APPROVAL A Without Approvals C UL 1077 Recognized W UL 1077 Recognized & TUV Certified IEC/ EN 60947-2 9 7 CURRENT RATING (AMPERES) 6 AMPERES 415 517 420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 10 Mounting Inserts 10 MOUNTING INSERTS A 6-32 Thread B M3 Thread 5 AUXILIARY SWITCH 0 Without Aux Switch CODE 9 Actuator Color & Legend 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 3 POLES 7 1 One 2 Two 3 Three 4Four 10 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 2450.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 8 Terminal 10 C 8 TERMINAL 8 2 Screw, 10-32 3 Stud, 1/4-20 5 Screw, M5 6 Stud, M6 1 SERIES C 2 2 A 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 www.carlingtech.com 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 62222.000 624 24.000 62525.000 63030.000 63535.000 64040.000 65050.000 66060.000 66565.000 670 70.000 67575.000 680 80.000 68585.000 69090.000 69595.000 810100.000 911115.000 912125.000 Notes: 1 Only available when tied to a protected pole Requires special P/N consult factory for details 2 Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10 3 Contacts Rated for 20A @ 80 VDC 4 440VDC Rating available in two different wiring configurations. (see next page for more details) 5 600 VDC only available with factory installed terminal bus (see next page for more details) 6 Single pole units available up to 125A, multi pole units limited to 115A Max. (see next page for more details) 7 3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special Part Number. (see next page for more details) 8 Screw Terminals are limited to 50A max. 9 Agency approval code W only available with 440 VDC rating & circuit code B. 10 4 Pole 600 VDC units only available up to 75A Max. (see next page for more details) 9 C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme Dimensional Specifications: in. [mm] 0.755 0.755 [19.18] [19.18] MAXIMUM MAXIMUM 0.380 [9.65] 0.579 [14.72] 1.052 [26.72] 1.052 [26.72] +0.050 3.094 –0.020 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] 1.052 [26.72] 2.259+0.020 [57.38+0.50] 1.719 1.719 [43.66] [43.66] 0.265 [6.73] 0.380 0.380 [9.65] 0.755 [9.65] [19.18] MAXIMUM +0.050 3.094 +0.050 –0.020 3.094 –0.020 +1.27 78.59 +1.27 2.062+0.02078.59 –0.50 –0.50 2.062+0.020 [52.37+0.50] [52.37+0.50] 1.719 [43.66] 0.502 [12.75] 0.502 0.502 [12.75] [12.75] 1.843+0.020 1.843+0.020 [46.81+0.50] [46.81+0.50] 30.0º 30.0º 0.124 [3.16] 0.124 [3.16] 1.843+0.020 [46.81+0.50] 2.264+0.020 [57.51+0.50] 2.264+0.020 [57.51+0.50] 0.626+0.020 [15.90+0.50] 0.626+0.020 [15.90+0.50] 30.0º 0.124 [3.16] 1.017 [25.82] 1.017 [25.82] 0.626+0.020 [15.90+0.50] 2.264+0.020 [57.51+0.50] 1.515 [38.48] 1.515 MAXIMUM [38.48] MAXIMUM 1.515 [38.48] MAXIMUM 2.259+0.020 2.259+0.020 [57.38+0.50] [57.38+0.50] 0.265 0.265 [6.73] [6.73] 0.579 0.579 [14.72] [14.72] SHOWN WITH STUD TERMINAL SHOWNCONFIGURATION WITH STUD TERMINAL CONFIGURATION SHOWN WITH STUD TERMINAL CONFIGURATION 3.672 [93.268] 3.672 [93.268] 1.017 [25.82] 2.259 [57.38] 2.259 [57.38] 3.672 [93.268] & (205/410 VDC) & (205/410 VDC) 2.259 [57.38] 0.744 [18.90] 0.744 [18.90] & 05/410 VDC) 0.744 [18.90] 2.736 [69.49] (WITH SCREW TERMINAL) 2.946 [74.83] (WITH STUD TERMINAL) 3.276 [83.21] (UNFOLDED BARRIER) 2.736 [69.49] 2.736 (WITH SCREW TERMINAL) [69.49] 2.946 (WITH SCREW TERMINAL) [74.83] 2.946 (WITH STUD TERMINAL) [74.83] 3.276 (WITH STUD TERMINAL) [83.21] 3.276 BARRIER) (UNFOLDED SHOWN WITH SCREW [83.21] TERMINAL CONFIGURATION (UNFOLDED BARRIER) SHOWN WITH SCREW TERMINAL CONFIGURATION SHOWN WITH SCREW TERMINAL CONFIGURATION TOLERANCES1.520 +.005[.12] [38.61] TOLERANCES +.005[.12] 0.760 [19.30] 1.062 [26.97] TOLERANCES +.005[.12] 1.520 [38.61] 1.520 0.760 [38.61] [19.30] 0.760 [19.30] 1.062 [26.97] 1.062 2.062[26.97] 0.078 TYP [52.37] 2.062[1.98] [52.37] CX1 0.625 [15.88] CX1 CX2 0.625 [15.88] CX2 0.078 TYP [1.98] 0.078 TYP [1.98] 0.750 TYP [19.05] 0.750 TYP [19.05] 2.062 [52.37] 0.625 [15.88] CX1 CX2 0.750 TYP [19.05] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 10 www.carlingtech.com CX-Series Circuit Breaker - UL489B – Dimensional Specifications Dimensional Specifications: in. [mm] OPTIONAL VOLTAGE POLE SEE NOTE 1 POLE 1 CX3 POLE 2 CX2 POLE 3 CX3 - 2 POLE SWITCH (CX2)SHOWN WITH OPTIONAL VOLTAGE POLE 50A-100A DEVICE, 600VDC POLE 1 OPTIONAL VOLTAGE POLE SEE NOTE 2 POLE 2 SEE NOTE 3 POLE 3 POLE 4 POLE 5 CX5 - 4 POLE SWITCH (CX4)SHOWN WITH OPTIONAL VOLTAGE POLE 101A-175A DEVICE, 600VDC Notes: 1 All dimensions are in inches [millimeters]. 2 3 pole configuration supplied with voltage coil on pole 1. Optional location pole 3. Consult factory. 3 5 pole configuration supplied with voltage coil in center pole. (Pole 3) 4 Line & Load connections requires bus connection as shown. Minimum cross selection .127 in2 (81.94 mm2) www.carlingtech.com 11 CX-Series Circuit Breaker - UL1077 – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 600V Rating requires minimum of 2 protected poles 12 www.carlingtech.com C-Series C-Series Circuit Breaker - Introduction C-Series CIRCUIT BREAKER The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life. Available with American Standard or Metric Threaded Stud terminals , or Saddle Clamp screw terminals. The optional mid-trip handle style actuator allows a visual indication of electrical overload with or without alarm feature. Product Highlights: Extensive list of Agency Approvals Available with Standard or Metric Stud terminals, or Saddle Clamp screw terminals Optional mid-trip handle style actuator Unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps Exclusive Rockerguard and Push-To-Reset bezel Available with new solid color and two-color Visirocker® actuators New thermoset glass filled polyester half shell construction Only Renewable Energy applicable ordering schemes and drawings are shown in this catalog. For complete product details, please visit www.carlingtech.com www.carlingtech.com 13 C-Series Circuit Breaker - General Specifications Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. Trip Free All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles Internal Circuit Config. Weight Standard Colors 1-6 poles ≤ 50A; 1-4 poles @ 5170A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & midtrip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) 1000 CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 15 25 20.1 - 50.0 35 100 10 O H M S 1 60 Hz 1/2 Cycle Inrush Pulse Tolerance 0.1 Multiple of Rated Current Ir 0.01 0.001 0.01 0.1 1 10 Time Delay Curves 42, 44 & 46 (50 Amps Max.) 25x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x 100 t AMPERE RATING 4.165 8.33 16.67 Pulse Tolerance Curves CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 15% 60 Hz5.1 1/2- 20.0 Cycle 20.1 -Tolerance 100 Inrush Pulse 25% 35% Ir FIGURE Time Delay Curves 1 Multiple of Rated Current Multiple of Rated Current Ir 42, 44 & 46 (50 Amps Max.) 25x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x t t 4.165 Ir Multiple of Rated Current 50 Hz 1/2 Cycle Inrush Pulse Tolerance 8.33 5.0 10.0 16.67 50 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x 20.0 Time in Milliseconds Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40°C to +85°C t 5.0 10.0 20.0 *Manufacturer reserves the right to change product specification without prior notice. Time in Milliseconds 14 www.carlingtech.com C-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS VOLTAGE CIRCUIT CONFIGURATION SERIES CURRENT RATING FREQUENCY PHASE FULL LOAD AMPS 32 DC --- 0.02 - 100 --- --- 48 DC --- 110 - 150 --- --- 65 DC --- 0.02 - 70 --- 80 DC --- 80 DC --- 125 DC 125 / 250 250 NOTES UL CSA 5000 TC1, OL1, U2 TC1, OL1, U2 5000 TC1, OL1, U2 TC1, OL1, U2 --- 5000 TC1,2, OL1,U1 TC1,2, OL1,U1 --- 71 -100 --- 5000 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 --- 71 -100 --- 7500 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 10,000 TC1,2, OL1,U1 TC1,2, OL1,U1 Must Have Agency Code "L" --- 71 -100 --- 10,000 TC1,2, OL0,U1 TC1,2, OL0,U1 Must Have Agency Code "L" --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L". 2 Pole Break Required for 250 Volts 0.02 - 100 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" Must Have Agency Code "L" 50 / 60 1 150 DC --- --- 80 - 100 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" 150 DC --- --- 101 - 175 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" Parallel Pole 0.02 - 100 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 125 / 250 50 / 60 1 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 51 - 100 --- --- 1000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 0.02 - 100 --- --- 5000 TC1,2,OL1,U2 TC1,2,OL1,U2 2 or 3 poles breaking single phase, "L" Agency Code 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 51 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 0.02 - 100 --- 3000 TC1, OL0, U2 TC1, OL0, U2 0.02 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase --- 0.02 - 90 --- 5000 TC1,2,OL0,U1 TC1,2,OL0,U1 Must Have Agency Code "L" 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 50 / 60 3 277 50 / 60 1 480 / 277 50 / 60 3 480 50 / 60 1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 TC1,2, OL1,U1 2 or 3 poles breaking single phase 3 poles breaking 3 phase 2 poles breaking 1 phase 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 125 50 / 60 1 0.02 - 50 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 125 / 250 50 / 60 1 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 250 50 / 60 0.02 - 50 --- --- 3000 TC1, OL0, U2 TC1, OL0, U2 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 DUAL COIL SWITCH ONLY APPLICATION CODES 125 250 RELAY UL/CSA WITH BACKUP WITHOUT BACKUP GENERAL PURPOSE AMPS FUSE FUSE 1 MAX. RATING 1 SHUNT SHORT CIRCUIT CAPACITY (AMPS) 1 3 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 Per Pole Rating 3 poles breaking 3 phase 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 480 / 277 50 / 60 3 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase TC1,2,OL0,C1 480 50 / 60 1 --- 31 - 50 5000 --- TC1,2,OL0,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 TC1,2, OL1,U1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 65 DC --- 0.02 - 70 --- --- --- --- --- 80 DC --- 125 50 / 60 125 / 250 50 / 60 250 50 / 60 277 50 / 60 480 / 277 50 / 60 --- 71 -100 --- --- --- --- 0.02 - 70 --- --- --- --- --- --- 71 -100 --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 3 0.02 - 70 --- --- --- --- --- 1 0.02 - 50 --- --- --- --- --- 0.02 - 30 --- --- --- --- --- --- 31 - 50 --- --- --- --- 3 2 poles breaking 1 phase 3 poles breaking 3 phase 2 or 3 poles breaking single phase 3 poles breaking 3 phase Notes: 1. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating www.carlingtech.com 15 C-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. RELAY Notes: 1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with series fusing as stated above in note 1. * Series, Shunt and Relay Trip - Voltage Coil Construction not current coils Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1. General Purpose ratings for UL/CSA only. 2. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION SERIES DUAL COIL INTERRUPTING CAPACITY (AMPS) WITHOUT FULL LOAD BACKUP FUSE AMPS CURRENT RATING VOLTAGE CONSTRUCTION NOTES MAX. RATING FREQUENCY PHASE 80 DC --- 0.10 - 100 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 120 50 / 60 1 0.10 - 50 10,000 1 - 3 Poles 51 - 70 5,000 1 - 3 Poles 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 50,000 1 Limited to 2 Poles Max from 71 - 100 Amps. 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 120 / 240 50 / 60 1 0.10 - 50 10000 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 240 50 / 60 1 0.10 - 30 5,000 1Pole 240 50 / 60 1 0.10 - 20 5,000 2 Pole 277 50 / 60 1 0.10 - 20 10,000 1Pole 120 50 / 60 1 0.10 - 30 10,000 --- Notes from Table D: 1. Special catalog number required. Consult factory. 16 www.carlingtech.com C-Series Circuit Breaker - General Specifications Electrical Tables Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, FIle 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) CSA Certified UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection Circuit Breaker Model Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M TUV Certified EN60934, under License No. R72040875 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489 UL Standard 489A www.carlingtech.com Communications Equipment (Guide CCN/DITT, File E189195) 17 C-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES C 9 Actuator Color C 10 Mounting Bezel/Barrier 11 Agency Approval CODEAMPERES Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 2 Two 1 2 1 8 Terminal 7 CURRENT RATING (AMPERES) 2 ACTUATOR 1 A B S T 450 7 Current Rating 3 4 Three Four 4 CIRCUIT 3 A 3 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) 4 D Shunt Trip (Current) 4 E Shunt Trip (Voltage) 5 6 Five Six F 4 Relay Trip (Current) G 4 Relay Trip (Voltage) H 4,5 Dual Coil with Shunt Trip Voltage Coil K 4,5 Dual Coil with Relay Trip Voltage Coil 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 3 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 4 pole max with VDE. 5th pole available as Series Trip with Voltage Coil only. 3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D, F, H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 12 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 No marking available. Consult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) or I-O markings on all handles. 17 Single pole only. 18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 18 A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 15 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 6 12 7 13,15 9 15 A 14 C 11,15 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Click Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16 Actuator Color I-O ON-OFF Dual Legend Color White AB 1Black Black CD 2White Red FG 3White Green HJ 4White Blue KL 5White Yellow MN 6Black Gray PQ 7Black Orange RS 8Black Black (short handle)17 TU 9 White 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches yes 18 C 6-32 X 0.195 inches yes 2 ISO M3 x 5mm no B ISO M3 x 5mm yes D 18 ISO M3 x 5mm yes Front panel Snap-In, 1.00” [25.4mm] wide bezel 17 E with Handleguard no VOLTAGE < 300 < 300 ≥ 300 < 300 < 300 ≥ 300 < 300 11 AGENCY APPROVAL C UL Recognized, CSA Accepted D VDE Certified, UL Recognized, CSA Accepted E TUV Certified, UL Recognized, CSA Accepted H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), CSA Accepted L UL489 Construction: UL Recognized, CSA Accepted R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted www.carlingtech.com C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES C 7 Current Rating 1 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers K G 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) CODEAMPERES 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 450 2 Two 3 Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 3 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 26 42 4 44 4 46 4 52 4 54 4 56 4 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has the same construction as poles 1 & 2. 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes 2, 3 & 4 only. Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Codes 9 & C are not VDE approved. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. www.carlingtech.com 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 8 TERMINAL 6 1 7 Stud 10-32 2 8 Screw 10-32 3 9 Stud 1/4-20 4 8 Stud M5 x 0.8 5 8 Screw M5 x 0.8 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 6 9 9 9 A 10 C 8 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 66060.000 67070.000 68080.000 68585.000 69090.000 69595.000 810100.00 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 11 Actuator Color ON-OFF Dual Legend Color White B1Black Black D2White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert 1 6-32 x 0.195 inches 2 ISO M3 x 5mm BARRIERS 12 yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 2 D 240 AC K 120 AC F 277 AC M 80 DC 12 AGENCY APPROVAL 11 A without approvals F UL489 Listed, CSA Certified & VDE Certified G UL489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified 19 C-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme C M 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 10 6 Frequency & Delay Sealed Toggle, one per pole 2 Two 3 Three 4 CIRCUIT A 2 Switch Only (no coil) B Series Trip (current) C Series Trip (voltage) D 3 Shunt Trip (current) E 3 Shunt Trip (voltage) F 3 G 3 H 3,4 K 3,4 Relay Trip (current) Relay Trip (voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 2 DC 50/60Hz, Switch Only 10 6 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code M: Handle location as viewed from front of breaker: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. 4 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. 8 Consult factory for current ratings 71-100, in three pole units, available as special catalog number only. 9 Terminal Code 1 available to 60 amps maximum. 10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 11 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 12 Terminal Code 7 available to 25 amps maximum. 13 Terminal Code A available to 100 amps maximum. 20 9 Legend Plate C 10 Mounting Bezel/Barrier 11 Agency Approval CODEAMPERES 2 ACTUATOR 1 3 POLES 1 One 1 0 1 8 Terminal 7 CURRENT RATING (AMPERES) 9 1 SERIES C M 450 7 Current Rating 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 9 Stud 10-32 2 10 Screw 10-32 11 3 Stud 1/4-20 4 10 Stud M5 x 0.8 5 10 Screw M5 x 0.8 J12 J18 J24 J48 6 11 7 12 9 11 A 13 C 10 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Click Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 LEGEND PLATE 0 No Legend 10 MOUNTING / BARRIERS MOUNTING STYLE 1 Standard Hex Nut A Standard Hex Nut (multi-pole units only) BARRIERS no yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted I UL Recognized & CSA Accepted, UL1500 ignition protection L UL Recognized & CSA Accepted with listed construction www.carlingtech.com C-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme C C 3 1 Series 2 Actuator 14 B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 450 6 Frequency & Delay 1 SERIES C 9 Actuator Color 10 Mounting/ Barriers D 11 Agency Approval CODEAMPERES 2 Two 3 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) 5 AUXILIARY / ALARM SWITCH 6 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 8 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxiliary switch codes 2, 3 & 4 are VDE approved. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 Color shown is visi and legend with remainder of rocker black 17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rockerguard available with actuator codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V. 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. www.carlingtech.com 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES 3 POLES 2 One 8 Terminal 7 CURRENT RATING (AMPERES) 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF,vertical legend O Indicate OFF,horizontal legend P Indicate OFF,no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset, Single color R Vertical legend U Horizontal legend V No legend 1 1 2 1 7 Current Rating A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 6 12 Stud M6 7 13 0.250 Double Quick Connect 9 7/16” Clip Terminal A 14 Plug-In Stud C 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16,17,18 Actuator or Visi-Color Marking: Marking Color: Single Color Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 10 MOUNTING / BARRIERS 1 STANDARD ROCKER BEZEL 1 6-32 x 0.195 inches 2 6-32 x 0.195 inches 3 19 6-32 x 0.195 inches 4 ISO M3 x 5mm 5 ISO M3 x 5mm 6 19 ISO M3 x 5mm ROCKERGUARD BEZEL A 6-32 x 0.195 inches C 6-32 x 0.195 inches E 19 6-32 x 0.195 inches G ISO M3 x 5mm J ISO M3 x 5mm L 19 ISO M3 x 5mm PUSH-TO-RESET BEZEL B 6-32 x 0.195 inches D 6-32 x 0.195 inches 19 F 6-32 x 0.195 inches H ISO M3 x 5mm J ISO M3 x 5mm 19 M ISO M3 x 5mm BARRIERSVOLTAGE no <300 yes <300 yes ≥300 no <300 yes <300 yes ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted H UL489 Construction: VDE Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted L UL489 Construction: UL Recognized & CSA Accepted R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted 21 C-Series Circuit Breaker - Rocker UL Listed – Ordering Scheme C C 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 Single color J Vertical legend K Horizontal legend ROCKER STYLE DESCRIPTIONS INDICATE "ON" VERTICAL STYLE INDICATE "OFF" SINGLE COLOR CODE "F" CODE "J" CODE "C" INDICATE COLOR LOCATION HORIZONTAL STYLE K G 10 Mounting/ Barriers 11 Max. App. Rating 12 Agency Approval CODEAMPERES 2 ACTUATOR 1 LINE LINE CODE "G" CODE "K" LINE 2 8 TERMINAL 1 5 Stud 10-32 2 6 Screw 10-32 with saddle & washer clamps 3 7 Stud 1/4-20 4 6 Stud M5 x 0.8 5 6 Screw M5 x 0.8 with saddle & washer clamps LINE Two 3 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.00 5 AUXILIARY / ALARM SWITCH 2 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 8 44 8 46 8 52 8 54 8 56 6 7 9 7,8 A 7,8 C 6,8 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal Three 4 CIRCUIT B Series Trip (current) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 LINE CODE "D" 3 POLES 1 1 One 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 Available up to 50 amps maximum. 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 5 Terminal Code 1 available to 60 amps maximum. 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 8 Terminal Codes 9 & C are not VDE approved. 9 Color shown is visi and legend with remainder of rocker black 10 Dual = ON-OFF/I-O legend on actuator. 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 12 Rockerguard available with all actuator codes. 13 Barriers supplied on multi-pole units only. 14 2 & 3 pole circuit breakers required for 120/240 AC rating. 22 9 Actuator Color 7 CURRENT RATING (AMPERES) 4 1 SERIES C LINE 1 2 A 8 Terminal 9 ACTUATOR COLOR & LEGEND 11 Actuator or Visi-Color Marking: Marking Color: Single Color 10 Color: ON-OFF Dual Rocker/Handle White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q7 Black Orange S 8 Black 10 MOUNTING / BARRIERS 12 Standard Rocker Bezel Threaded Insert, 2 per pole A 6-32 X 0.195 inches C ISO M3 x 5mm Rockerguard Bezel Threaded Insert, 2 per pole B 6-32 x 0.195 inches D ISO M3 x 5mm Visi-Rocker White n/a Red Green Blue Yellow Gray Orange BARRIERS 13 yes yes yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 14 D 240 AC F 277 AC K 120 AC M 80 DC 12 AGENCY APPROVAL A without approvals F UL 489 Listed, CSA Certified, & VDE Certified G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified www.carlingtech.com C-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme C 1 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 10 450 6 Frequency & Delay 7 Current Rating 9 Actuator Color 10 Mounting/ Barriers E 11 Agency Approval 7 CURRENT RATING (AMPERES) 9 1 SERIES C CODEAMPERES 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 3 POLES 2 1 One 1 2 1 8 Terminal 2 Two 3 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) D 4 Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) 5 AUXILIARY / ALARM SWITCH 6 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 8 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Push-to-reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxilary switch codes 2, 3 & 4 are VDE approved. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 - 100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are available in ink stamping only. www.carlingtech.com 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES Three S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 6 12 7 13 9 15 A 14 C 15 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Quick Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16,17,18 Actuator or Visi-Color Marking: Marking Color: Single Color Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 10 MOUNTING / BARRIERS 1 STANDARD ROCKER BEZEL 1 6-32 x 0.195 inches 2 6-32 x 0.195 inches 19 3 6-32 x 0.195 inches 4 ISO M3 x 5mm 5 ISO M3 x 5mm 19 6 ISO M3 x 5mm RECESSED OFF ROCKER 7 6-32 x 0.195 inches 8 6-32 x 0.195 inches 9 6-32 x 0.195 inches A ISO M3 x 5mm C ISO M3 x 5mm E ISO M3 x 5mm PUSH-TO-RESET BEZEL B 6-32 x 0.195 inches D 6-32 x 0.195 inches F 19 6-32 x 0.195 inches H ISO M3 x 5mm J ISO M3 x 5mm M 19 ISO M3 x 5mm BARRIERSVOLTAGE no <300 yes <300 yes ≥300 no <300 yes <300 yes ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 11 AGENCY APPROVAL C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted L UL489 Construction: UL Recognized & CSA Accepted R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted 23 C-Series Circuit Breaker - Flat Rocker UL Listed – Ordering Scheme C 1 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating 1 2 A 8 Terminal 9 Actuator Color 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 8 TERMINAL 1 7 Stud 10-32 2 8 Screw 10-32 3 9 Stud 1/4-20 4 8 Stud M5 x 0.8 5 8 Screw M5 x 0.8 2 Two 3 Three 4 CIRCUIT B Series Trip (current) 5 AUXILIARY / ALARM SWITCH 2 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 4 50/60Hz Short, Hi-Inrush 44 4 50/60Hz Medium, Hi-Inrush 46 4 50/60Hz Long, Hi-Inrush 52 4 DC Short, Hi-Inrush 54 4 DC Medium, Hi-Inrush 56 4 DC Long, Hi-Inrush 1 Notes: 2 Push-to-reset actuators have OFF portion of rocker shrouded. 3 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 4 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 5 Available up to 50 amps maximum. 6 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 10 Terminal Codes 9 & C are not VDE approved. 11 Color shown is visi and legend with remainder of rocker black 12 Dual = ON-OFF/I-O legend on actuator. 13 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 14 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 15 5 & 6. 16 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker are available in ink stamping only. 17 Barriers supplied on multi-pole units only. 18 2 & 3 pole circuit breakers required for 120/240 AC rating. 24 12 Agency Approval CODEAMPERES 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 11 Max. App. Rating 7 CURRENT RATING (AMPERES) 5 1 SERIES C 3 POLES 2 1 One K G 10 Mounting/ Barriers 6 9 9 9,10 A 9 C 8,10 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 12 Actuator or Visi-Color Marking: Marking Color: Single Color 11 Color: ON-OFF Dual Rocker/Handle White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q7 Black Orange S 8 Black 10 MOUNTING / BARRIERS 12 STANDARD ROCKER BEZEL Threaded Insert, 2 per pole A 6-32 X 0.195 inches C ISO M3 x 5mm RECESSED OFF ROCKER 14 Threaded Insert, 2 per pole E 6-32 x 0.195 inches F ISO M3 x 5mm PUSH-TO-RESET BEZEL 13 Threaded Insert, 2 per pole B 6-32 x 0.195 inches D ISO M3 x 5mm 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.00 Visi-Rocker White n/a Red Green Blue Yellow Gray Orange BARRIERS 15 yes yes yes yes yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 16 D 240 AC F 277 AC K 120 AC M 80 DC 12 AGENCY APPROVAL A without approvals G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified www.carlingtech.com C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one auxiliary switch is normally supplied, as viewed in mulit-pole identification scheme. www.carlingtech.com 25 C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. 26 www.carlingtech.com C-Series Circuit Breaker - Handle – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 27 C-Series Circuit Breaker - Handleguard – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 28 www.carlingtech.com C-Series Circuit Breaker - Arc Chute Barrier UL Recognized/Listed – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Only 1-pole and 3-pole configurations shown. Arc chute (without barrier) and arc chute barrier also available for 2-pole construction. 2 Dimensions apply to all variations shown. 3 Notice that line and load terminal orientation for indicate on and indicate off rocker circuit breakers are opposite. 4 Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For other terminal configurations see circuit and terminal diagrams. 5 All dimensions are in inches [millimeters]. 6 Tolerance ± .020 unless otherwise specified. 7 Must be ordered under a special catalog number. www.carlingtech.com 29 C-Series Circuit Breaker - Sealed Toggle – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 30 www.carlingtech.com C-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. www.carlingtech.com 31 C-Series Circuit Breaker - Rocker – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 32 www.carlingtech.com C-Series Circuit Breaker - Flat Rocker – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 33 E-Series E-Series Circuit Breaker - Introduction E-Series CIRCUIT BREAKER The E-Series hydraulic-magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Product Highlights: UL listed and CSA certified Certified for circuit branch protection Recognized as a supplementary protector and as a manual motor controller Optional power selector device 34 www.carlingtech.com E-Series Circuit Breaker - General Specifications Electrical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Table A) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC (with gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 ± 15 ± 25 20.1 - 50.0 ± 35 Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Physical Number of Poles Mounting Connectors, Box Type Internal Circuit Configuration Weight Standard Colors 1-6 A 3” minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. E-Series circuit breakers must be mounted on a vertical surface. Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Approximately 252 grams/pole (Approximately 9 ounces/pole) Housing-Black; Actuator - See Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Pulse Tolerance Curves Time Delay Curves 62, 64 & 66 (100 Amps Max.) Time Delay Curves 22, 24 & 26 (100 Amps Max.) Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 35 E-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION SERIES CURRENT RATING MAX. RATING FREQUENCY PHASE FULL LOAD AMPS INTERRUPTING CAPACITY (AMPS) HIGH INTERRUPTING CAPACITY WITHOUT BACKUP (AMPS) FUSE 80 DC --- 0.10 - 100 5,000 50,000 125 DC --- 0.10 - 100 5,000 10,000 125 DC --- 0.10 - 125 10,000 --- 120 50 / 60 1 0.10 - 125 10,000 --- 240 240 50 / 60 50 / 60 1 1 0.10 - 30 31 - 100 5,000 5,000 10,000 120 / 240 50 / 60 1 0.10 - 30 5,000 10,000 120 / 240 50 / 60 1 31 - 100 5,000 --- 120 / 240 50 / 60 1 101 - 125 10,000 --- 240 50 / 60 3 0.10 - 100 5,000 --- Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) UL/CSA FULL LOAD GENERAL FREQUENCY PHASE WITH BACKUP WITHOUT AMPS PURPOSE AMPS FUSE3 BACKUP FUSE VOLTAGE CIRCUIT CONFIGURATION MAX. RATING APPLICATION CODES UL CSA 125 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 125 150 DC DC ----- ----- 101 - 120 0.02 - 125 ----- 5,000 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 TC1, OL0, U3 TC1, OL0, U3 160 150 / 300 DC DC ----- 0.02 - 100 0.02 - 100 ----- ----- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL1, U1 SERIES & 120 / 240 50 / 60 1 --- 0.02 - 100 --- 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 SHUNT 240 250 50 / 60 50 / 60 1 1 0.02 - 100 0.02 - 100 ----- --10,000 5,000 --- TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL1, C1 TC1,2, OL1, C1 277 50 / 60 1 0.02 - 100 --- --10,000 5,000 --- TC1,2, OL1, U1 TC1,2, OL1, U1 TC1,2, OL1, C1 TC1,2, OL1, C1 480 50 / 60 50 / 60 50 / 60 1&3 1&3 1&3 0.02 - 100 0.02 - 50 0.02 - 100 ------- 10,000 10,000 10,000 ------- TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 TC1,2, OL1, C1 DC --- --- 0.02 - 125 --- 5,000 DC --- 0.02 - 120 160 DC --- 0.02 - 100 240 277 50 / 60 50 / 60 1 1 0.02 - 100 0.02 - 100 480 600 50 / 60 50 / 60 1&3 1&3 0.02 - 100 0.02 - 100 480 1 600 600 2 125 SWITCH ONLY TC1, OL0, U3 TC1, OL0, U3 Notes: 1 Per pole opposite polarity rating - Delta Configuration. 2 4 Poles connected in series 3 Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225A. 36 www.carlingtech.com E-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE CURRENT RATING VOLTAGE CIRCUIT CONFIGURATION SHORT CIRCUIT CAPACITY (AMPS) UL/CSA MAX. FREQUENCY PHASE FULL LOAD AMPS WITH BACKUP RATING FUSE1 125 DC --- 0.1 - 100 --- WITHOUT BACKUP FUSE WITHOUT BACKUP FUSE 5,000 5,000 SERIES & 240 50 / 60 1&3 0.1 - 100 --- 5,000 5,000 SHUNT 415 50 / 60 1&3 0.1 - 100 10,000 --- 4,000 SWITCH ONLY 125 DC --- 0.1 - 125 240 50 / 60 1&3 0.1 - 100 415 50 / 60 1&3 0.1 - 100 APPLICATION CODES VDE (Icn) UL CONSTRUCTION NOTES CSA TC1,2, OL1, U1 TC1,2, OL1, U1 1 or 2 Poles 1 - 5 Poles. Up to 4 TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage Pole 2 - 5 Poles. Up to 4 TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage Pole Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps. Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. E SERIES TABLE D : UL1500 (Marine Ignition Protection) VOLTAGE CIRCUIT CONFIGURATION SERIES MAX. RATING FREQUENCY CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA PHASE APPLICATION CODES 65 DC --- 0.02 - 100 5,000 TC1,2,OL1,U1 TC1,2,OL1,U1 125 50 / 60 1 0.02 - 100 1,500 TC1,2,OL1,U1 TC1,2,OL1,U1 250 50 / 60 1 0.02 - 100 1,500 TC1,2,OL1,U1 TC1,2,OL1,U1 Agency Certifications UL Recognized UL Standard 1077 UL Standard 1500 UL Listed UL Standard 489 www.carlingtech.com Component Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596) CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 Component Recognition Program as Manual Motor Controls (Guide NLRV2, File E135367) CSA Certified Circuit Breaker Molded Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection TUV Certified EN60934 under License No. R72031056 VDE Certified EN60934, VDE 0642 under File No. 10537 Circuit Breakers, Molded Case (Guide DIVQ, File E129899) 37 E-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme E A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Auxiliary Switch 24 450 6 Frequency & Delay 7 Current Rating 2 ACTUATOR A Handle, one per pole 3Three 4Four 4 CIRCUIT 2 A 3 Switch Only (no coil) B Series Trip (current) C Series Trip (voltage) D Shunt Trip (current) 6 FREQUENCY & DELAY 03 3 DC 50/60Hz, Switch Only 10 5 DC Instantaneous 12 DC Short 14 DC Medium 16 DC Long 20 5 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 32 DC, 50/60Hz Short E F G Shunt Trip (voltage) Relay Trip (current) Relay Trip (voltage) S.P.S.T. 0.110 Q.C. Terminals S.P.S.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.S.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 76 DC, Long, Hi-Inrush 92 6DC, 50/60Hz Short, Hi-Inrush 94 6DC, 50/60Hz Medium, Hi-Inrush 96 6DC, 50/60Hz Long, Hi-Inrush 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 613 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 5 A06 6 DC, 5 DC A65 65 DC, 55 DC J48 A12 12 DC, 10 DC B25 125 DC, 100 DC J65 A18 18 DC, 15 DC J06 6 AC, 5 AC K20 A24 24 DC, 20 DC J12 12 AC, 10 AC L40 A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC 614 615 616 617 618 620 622 624 625 630 635 640 650 660 670 680 690 810 811 812 912 8 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 60.000 70.000 80.000 90.000 100.000 110.000 120.000 125.000 48 AC, 40 AC 65 AC, 55 AC 120 AC, 65 AC 240 AC, 130 AC Notes: 1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. 2 Switch Only & Series Trip construction available with either front or back connected terminals. Shunt construction available with back connected terminals, (Terminal Codes 1 & 2) only. Circuit Codes B,C & D are VDE approved. 3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a protected pole. 38 11 Maximum Application Rating 12 Agency Approval MAX. RATING 50 A 120 A 50 A 100 A Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 10 MOUNTING / BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A6-32 B ISO M3 CODEAMPERES 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 420 522 425 527 10 Mounting/ Barriers 9 ACTUATOR COLOR & LEGEND 13 Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 7 CURRENT RATING (AMPERES) 7 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 0.250 0.300 9 Actuator Color FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 3 10 Box Wire Connector (Line & Load) 100 A 11 C Box Wire Connector with Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A D M5 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A E M5 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 6 10 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A F 11 10-32 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 100 A G M6 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A H M6 “Bus-Type” Screw (Line), M6 Screw (Load) 100 A 10 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A J 11 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 5Five 6Six 5 AUXILIARY SWITCH 4 0 without Auxiliary Switch 6 2 S.P.D.T. 0.110 Q.C. Terminals 7 3 S.P.D.T. 0.139 Solder Lug 4 S.P.D.T. 0.110 Q.C. Terminals 8 (Gold Contacts) 9 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 225 230 8 Terminal C B 8 TERMINAL 12 BACK CONNECTED (FRONT MOUNTED ONLY) 1 9 10-32 Stud (All Terminals) 2 9 1/4-20 Stud (All Terminals) A 9 M5 Stud (Line & Load) B 9 M6 Stud (Line & Load) 1 SERIES E 3 POLES 1 1 One 2Two 1 2 A FRONT CONNECTED (BACK MOUNTED ONLY) 14 Back Mounting Foot Type Front Mounting Inserts (Optional Use) CShort 6-32 D Short ISO M3 ELong 6-32 F Long ISO M3 11 MAXIMUM APPLICATION RATING 15 A 65 VDC, 120 A G 16 B 125 VDC, 120 A H 16 C 120/240 VAC, 100 A J 16 D 240 VAC, 100 A L 16 E 16 277/480 VAC, 100 A T F 277 VAC, 100 A W 16 600 VAC, 100 A 480 VAC, 100 A 415 VAC, 100 A 160 VDC, 100 A 125 VDC/240 VAC, 100 A 125 VDC/415 VAC, 100 A 12 AGENCY APPROVAL B UL 1077 / UL508 Recognized & CSA Accepted D UL 1077 Recognized, CSA Accepted, & VDE Certified 4 5 6 7 8 9 10 11 12 13 14 15 16 Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on Auxilary Switch Codes 0,2,3 & 4 only. Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to a protected pole. Frequency & Delay Codes 92,94 & 96 are not VDE Certified. Current Coil Ratings 0.100 - 100 ams are VDE Certified. 125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B). An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement. Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. Terminal Codes A,B,D,E,G & H are not VDE Certified. VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. Application ratings B,D,J,T & W are available with VDE. 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø. www.carlingtech.com E-Series Circuit Breaker - Handle UL Listed – Ordering Scheme E A 2 1 Series 2 Actuator 24 450 6 Frequency & Delay 7 Current Rating B 0 4 Circuit 3 Poles 5 Auxiliary Switch 2 ACTUATOR A Handle, one per pole 3 POLES 1 1 One 2Two 3Three 4Four 5Five 6Six 4 CIRCUIT 2 B Series Trip (current) C 3 Series Trip (voltage) 5 AUXILIARY SWITCH 4 0 without Auxiliary Switch 6 2 S.P.D.T. 0.110 Q.C. Terminals 7 3 S.P.D.T. 0.139 Solder Lug 4 S.P.D.T. 0.110 Q.C. Terminals 8 (Gold Contacts) 9 S.P.S.T. 0.110 Q.C. Terminals S.P.S.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.S.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 6 FREQUENCY & DELAY 10 5 DC Instantaneous 62 50/60Hz Short, Hi-Inrush 12 DC Short 64 50/60Hz Medium, Hi-Inrush 14 DC Medium 66 50/60Hz Long, Hi-Inrush 16 DC Long 72 DC, Short,Hi-Inrush 20 5 50/60Hz Instantaneous 74 DC,Medium, Hi-Inrush 22 50/60Hz Short 76 DC, Long, Hi-Inrush 24 50/60Hz Medium 26 50/60Hz Long 7 CURRENT RATING (AMPERES) 7 CODEAMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 0.250 0.300 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 7 BACK CONNECTED (FRONT MOUNTED ONLY) 1 8 10-32 Stud (All Terminals) 2 8 1/4-20 Stud (All Terminals) 1 SERIES E 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 225 230 1 2 A 8 Terminal 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 420 522 425 527 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 613 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 5 A06 6 DC, 5 DC A65 65 DC, 55 DC J48 A12 12 DC, 10 DC B25 125 DC, 100 DC J65 A18 18 DC, 15 DC J06 6 AC, 5 AC K20 A24 24 DC, 20 DC J12 12 AC, 10 AC L40 A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC www.carlingtech.com 614 615 616 617 618 620 622 624 625 630 635 640 650 660 670 680 690 810 811 812 912 8 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 60.000 70.000 80.000 90.000 100.000 110.000 120.000 125.000 48 AC, 40 AC 65 AC, 55 AC 120 AC, 65 AC 240 AC, 130 AC C C 11 Maximum Application Rating 12 Agency Approval MAX. RATING 50 A 125 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 3 9 Box Wire Connector (Line & Load) 100 A C 10 Box Wire Connector with Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 6 9 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A F 10 10-32 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 125 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 9 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A J 10 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 9 ACTUATOR COLOR & LEGEND 12 Actuator Color ON-OFF Dual Legend Color White B1Black Black D2White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black 10 MOUNTING / BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY) 11 Back Mounting Foot Type Front Mounting Inserts (Optional Use) CShort 6-32 D Short ISO M3 ELong 6-32 F Long ISO M3 11 MAXIMUM APPLICATION RATING 15 1 120 VAC B 125 VDC, 120 A 13 C 120/240 VAC, 100 A D 240 VAC, 100 A 12 AGENCY APPROVAL C UL 489 Listed & CSA Certified F UL 489 Listed, CSA Certified, & VDE Certified Notes: 1 Standard multi-pole units identical poles except when specifying auxiliary switch (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. 2 Series Trip construction available with either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole. 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. 7 Current Ratings under 0.100 amps are not VDE Certified . 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. 39 E-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. 40 www.carlingtech.com E-Series Circuit Breaker - Handle (Back Connected) – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. www.carlingtech.com 41 E-Series Circuit Breaker - Handle (Front Connected) – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. 42 www.carlingtech.com F-Series F-Series Circuit Breaker - Introduction F-Series CIRCUIT BREAKER The F-Series hydraulic-magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its time-proven hydraulic-magnetic design, the F-Series load sensing mechanism is insensitive to changes in ambient or enclosure temperature, providing a consistent trip point over temperatures ranging from -40°C to +85°C. Additionally, the F-Series circuit breakers come with a choice of overload time delays, making them ideal for critical applications having inductive loads. Further, the F-Series breakers are available up to 700A and an optional 25 millivolt metering shunt construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. Applications can be customized by measuring and displaying percentage of current, watts or safe/danger zones. Product Highlights: AC ratings to UL 489 DC voltage ratings up to 700A with metering shunt section Consistent trip point over temperatures ranging from -40°C to +85°C Optional 25 millivolt metering shunt construction www.carlingtech.com 43 F-Series Circuit Breaker - General Specifications Electrical Maximum Voltage 125VDC, 277VAC Current Ratings Standard current coils: 100, 125, 150, 175, 225, 250 amps. 300, 350, 400, 500, 600, 700 amps available as parallel pole construction. Auxiliary Switch Rating SPDT; 10.1 Amps @ 250VAC, 1.0 Amps @ 65VDC, 0.5 Amps @ 80VDC 0.1 Amps @ 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength 1960 VAC, 50/60 Hz for one minute between all electrically isolated terminals, except 2500 VAC for one minute between alarm/aux. switch and main terminals with contacts in open and closed position. F-Series circuit breakers comply with the 8mm spacing & 3750VAC 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxilary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE (AMPS) (%) 100 - 700 50 Mechanical Endurance 4000 ON-OFF operations with rated Current & Voltage & 4000 operations with no load (8000 operations total) @ 5 per minute. Parallel Pole construction: 1000 operations with rated Current and Voltage @ 5 per minute. Trip Free All F-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. Physical Number of Poles 1 - 3 Poles Note: Ratings over 250 Amps only available with parallel pole. Internal Circuit Config. Series (with or without auxiliary switch), Switch Only (with or without auxiliary switch). Available Accessories Factory installed: DC Current Metering Shunt (25 mV @lr) Weight Varies depending on construction. Consult factory. Standard Colors Housing - Black; Actuator- Black or White with contrasting ON-OFF legend. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. 44 www.carlingtech.com F-Series Circuit Breaker - General Specifications Table A: Lists ULTables Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance Electrical capabilities as a Molded Case Circuit Brekaer Table A: Lists UL Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance capabilities as a Molded Case Circuit Breaker F SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION SERIES MAX RATING CURRENT RATING FREQUENCY PHASE INTERRUPTING CAPACITY (AMPS) FULL LOAD AMPS UL / CSA 1 - 3 POLES TUV 2 1 or 2 POLES 125 DC --- 50 - 250 50,000 25,000 120 / 240 1 277 50 / 60 50 / 60 1 1 100 - 250 100 - 250 10,000 10,000 ----- 208Y / 120 50 / 60 3 100 - 250 10,000 --- Notes: NOTES: 1 120/240V rating available in 2 or 3 poles. In a 3 pole construction the center pole is Neutral. TUV constructions not availablein with and 150-250 ratings only. 1.2 120/240V ratingareavailable 2 AC orratings 3 poles. In a 3amp pole construction the center pole is Neutral. 2. TUV constructions are not available with AC ratings. Table B: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A Agency Certifications UL Listed UL 489 UL 489A www.carlingtech.com Circuit Breakers , Molded Case (Guide DIVQ, File E129899) Complies with the requirements of the CSA Standard for Molded Case Circuit Breakers, CANCSA- C22.2 No. 5.1 –M Circuit Breakers for Use in Communications Equipment (Guide DITT, File E189195) TUV Certified IEC 60947-2 Low Voltage Switchgear and Control Gear under TUV License No. R72031058 45 F-Series Circuit Breaker - Handle – Ordering Scheme F A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 2 ACTUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 2 4 CIRCUIT A 1 Switch Only (no coil) B Series Trip (current) C 2 Series Trip (voltage) Two 3 DC Medium DC Long AC Short AC Medium AC Long 7 CURRENT RATING (AMPERES) CODEAMPERES 810 912 815 917 100.000 125.00 150.00 175.00 820 200.00 922225.00 825 250.00 830 8 300.00 835 8350.00 840 8 400.00 845 8 450.00 850 8 500.00 860 8 600.00 870 8 700.00 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 7 CODEAMPERES A06 6 DC, 5 DC A12 12 DC, 10 DC A18 18 DC, 15 DC A24 24 DC, 20 DC A32 32 DC, 25 DC A48 48 DC, 40 DC 8 TERMINAL Back Connected (Front Mounted Only) 1 9 3/8-16 Stud 2 14 3/8-16 Screw, Line & Load 5 14 3/8-16 Short Stud Front Connected (Back Mounted Only) 11 3 Box Wire Connector, Line & Load 4 14 3/8-16 Screw, Line & Load 46 10 Mounting Dual 1 2 B G 11 Max. App. Rating 12 Agency Approval Marking Color Black White Back Mounting Inserts 10-32 screw clearance holes 10-32 screw clearance holes Three 5 AUXILIARY SWITCH 5 0 without Auxiliary Switch 7 S.P.S.T. 0.110 Q.C. Terminals 2 S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 3 S.P.D.T. 0.139 Solder Lug 8 S.P.S.T. 0.187 Q.C. Terminals 4 S.P.D.T. 0.110 Q.C. Terminals 9 S.P.D.T. 0.187 Q.C. Terminals (Gold Contacts) A 6 S.P.S.T., 0.093 Round 5 S.P.S.T., 0.093 Q.C. Terminals QC Terminals (Gold Contacts) B 6 S.P.D.T., 0.093 Round 6 S.P.S.T. 0.110 Q.C. Terminals QC Terminals 14 16 22 24 26 9 Actuator Color 10 MOUNTING Front Mounting Inserts A 10-32 B ISO M5 Parallel Pole Construction: M 3,4 Series Trip (Current) with Metering Shunt N 3,4 Switch Only with Metering Shunt P 3 Series Trip (Current) Q 3 Switch Only 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 7 Current Rating 1 2 A 8 Terminal 9 ACTUATOR COLOR & LEGEND 12,13 Actuator Color I-O ON-OFF White AB Black CD 1 SERIES F 3 POLES 1 One 820 A65 65 DC, 55 DC B25 125 DC, 100 DC J06 6 AC, 5 AC 11 MAXIMUM APPLICATION RATING VOLTAGECURRENT B 125 VDC 700A C 15 120/240250A F 277 VAC 250A 7 16 120/208 VAC 250A 12 AGENCY APPROVAL A No approvals G UL489 Listed & CUL Certified J UL489 Listed, CUL Certified & TUV Certified T UL489A (Telecom) Listed Notes: 1 For 100 to 250 amps, select Current Code 825. For 300-400 amps, select Current Code 840. For 450-700 amps, select Current Code 870. 2 Available with Frequency and Delay code 10 or 20 only, and are not rated for continuous duty. Delay 10 and 20 are only available with voltage coils. 3 3 Codes M, N, P & Q (Parallel Poles) are supplied with factory installed Bus Bar on Line and Load. 4 4 Metering terminals are female pin type, ref. Molex part number 02-09-1101, model 1189-T. 5 Auxiliary Switch breakers are only available with Series Trip and Switch Only circuits. On multi-pole breakers, one Auxiliary Switch is supplied, mounted in the extreme right pole per figure A. Back-Mounted breakers require special mounting provisions when an Auxiliary Switch is specified. 6 Available with parallel pole construction (circuit codes P and Q, and breakers with circuit codes M and N). 7 Frequency and delay code 10 is only available with Voltage Coils. Voltage Coils are not rated for continuous duty. 8 Ratings over 250 amps are only available with Agency Approval code T (UL489A) and are Parallel Pole configuration (circuit codes M, N, P and Q.) 300-450 amp ratings are available on two pole breakers. 500-700 amp ratings are available on three pole breakers. 9 Per UL requirement, an “Anti-Flash Over Barrier” is supplied between poles on multipole breakers with 3/8 - 16 stud terminals (Terminal Code 1) on AC rated breakers only. 10 Front connected breakers can also be front mounted by utilizing the supplied front panel mounting inserts. Terminal connections must be made before mounting. 11 Box Wire connector will accept #6 through 250 MCM copper wire. 12 Agency codes G & T must have ON-OFF or dual legends. Agency code J must have dual legend. 13 Other colors available. Consult factory. 14 Terminals 2,4 & 5 are shipped without terminal hardware. 15 2 or 3 Pole Circuit Breaker Required for 120/240 VAC Rating. 16 3 Pole Circuit Breaker Required for 120/208 VAC Rating. Max Rating 250A 700A 250A Max Rating 700A 700A www.carlingtech.com F-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 47 F-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 48 www.carlingtech.com F-Series Circuit Breaker - Handle – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 49 F-Series Circuit Breaker - Handle – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 50 www.carlingtech.com F-Series Circuit Breaker - Handle – Dimensional Specifications Dimensional Specifications: in. [mm] F-Series breakers are available up to 700A, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. You can customize the application by measuring and displaying percentage of current, watts or safe/ danger zones. Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 51 F-Series Circuit Breaker - Handle – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 52 www.carlingtech.com Time Delay Values - C, CX-Series Circuit Breakers A, B, C, CX, D, G, H, L, N-SERIES TIME VALUES PERCENT OF RATED CURRENT Notes: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curves 32,34,36: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve. Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. DC TRIP TIME IN SECONDS AC TRIP TIME IN SECONDS Instantaneous PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Ultrashort PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT www.carlingtech.com PERCENT OF RATED CURRENT 53 Time Delay Values - C, CX-Series Circuit Breakers TRIP TIME IN SECONDS DC TRIP TIME IN SECONDS AC Medium TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Long PERCENT OF RATED CURRENT TRIP TIME IN SECONDS High Inrush DC TRIP TIME IN SECONDS High Inrush AC Short TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Medium TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Long PERCENT OF RATED CURRENT 54 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT www.carlingtech.com Time Delay Values - C, CX-Series Circuit Breakers AC/DC TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Medium PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Long PERCENT OF RATED CURRENT www.carlingtech.com 55 Time Delay Values - E-Series Circuit Breaker NOTES Delay Curves 10,20,30: Breakers to hold 100% and must trip at 150% of rated current and greater wthin the time limit shown in these curves. Delay Curves 12,14,16,22,24,26,62,64,66,72,74,76: Breakers to hold 100% and must trip at 125% of rated current and greater wthin the time limit shown in these curves. Delay Curves 32,34,36,92,94,96: Breakers to hold 100% and must trip at 135% of rated current and greater wthin the time limit shown in these curves. All curves: Data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading: Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capacity on the above standard delays is 16 times rated current &20 times rated current for high inrush delays based on a 60Hz 1/2 cycle, 8.33 ms pulse. DC TRIP TIME IN SECONDS AC TRIP TIME IN SECONDS Instantaneous PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Medium PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Long PERCENT OF RATED CURRENT 56 PERCENT OF RATED CURRENT www.carlingtech.com Time Delay Values - E-Series Circuit Breaker TRIP TIME IN SECONDS Instantaneous AC/DC PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Medium PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Long PERCENT OF RATED CURRENT www.carlingtech.com 57 Time Delay Values - F-Series Circuit Breaker Short - AC 22 11 No Trip .013 - .125 .010 - .070 .008 - .032 .006 - .020 .005 - .020 .004 - .020 .004 - .020 12 No Trip .475 - 10.0 .275 - 2.80 .140 - .850 .030 - .190 .015 - .125 .010 - .050 .008 - .038 14 16 22 24 26 No Trip No Trip No Trip No Trip No Trip 10.0 - 110 110 - 1000 .700 - 12.0 10.0 - 160 50.0 - 700 6.00 - 40.0 60.0 - 400 .350 - 4.00 6.00 - 60.0 32.0 - 350 2.50 - 15.0 22.0 - 150 .130 - 1.30 .220 - 20.0 10.0 - 90.0 .500 - 3.00 4.00 - 25.0 .027 - .220 .300 - 3.00 1.50 - 15.0 .180 - 1.00 1.00 - 5.50 .008 - .130 .050 - 1.30 .500 - 7.00 .010 - .280 .008 - .080 .008 - .390 .004 - .045 .005 - .060 .006 - 2.00 AC Ultrashort - DC .010 - 1.80 .004 - .090 .007 - .500 .020 - 3.00 DC TRIP TIME IN SECONDS TRIP TIME IN SECONDS F SERIES 50/60 HZ SHORT CURVE NO. 22 PERCENT OF RATED CURRENT Short - DC PERCENT OF RATED CURRENT TRIP TIME IN SECONDS F SERIES 50/60 HZ MEDIUM CURVE NO. 24 TRIP TIME IN SECONDS Medium - AC 24 Medium - DC PERCENT OF RATED CURRENT Long - AC 26 TRIP TIME IN SECONDS F SERIES 50/60 HZ LONG CURVE NO. 26 PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Long - DC PERCENT OF RATED CURRENT 58 TRIP TIME IN SECONDS PERCENT OF RATED CURRENT www.carlingtech.com Carling Technologies Catalogs There are several catalogs available featuring complete details on all Carling Technologies products. Below is a list of useful information such as catalogs, brochures and videos. Please visit our website at carlingtech.com or scan the QR codes below for complete details. www.carlingtech.com Watch Company Profile Video Switches & Controls Hydraulic-Magnetic SWITCHES & CONTROLS Rocker, Toggle, Pushbutton & Rotary CATALOG Circuit Protection CATALOG catalog catalog Complete line and ordering details for Switches & Control products including Rocker, Toggle, Pushbutton, and Rotary style switches. Complete line and ordering details for all hydraulic-magnetic circuit breakers. Thermal GFCI / ELCI GFCI / ELCI THERMAL Circuit Protection Circuit Protection CATALOG catalog Complete line and ordering details for all thermal circuit breakers. www.carlingtech.com CATALOG catalog Complete line and ordering details for all GFCIs/ELCIs. 59 Carling Technologies Catalogs Marine On-Off Highway MARINE ON/OFF HIGHWAY Switches, Circuit Protection & ELCI/GFCIs Switches & Controls catalog brochure catalog brochure Complete line of ELCIs, thermal and hydraulic-magnetic circuit breakers specific for marine applications. Complete line of switches, controls and custom solutions specific for on-off highway applications. Renewable Energy Military MILITARY RENEWABLE ENERGY Circuit Breakers & Disconnects COTS Switches & Circuit Breakers catalog brochure catalog brochure Complete line of circuit breakers and disconnect products specific for renewable energy applications. Complete line of COTS (Commercial-Off-The-Shelf) switches and circuit breakers specific for military applications. Telecom/Datacom Industrial Automation TELECOM/DATACOM INDUSTRIAL AUTOMATION AND CONTROLS Circuit Protection Circuit Protection & Switches catalog brochure Complete line of hydraulic-magnetic circuit breakers specific for telecom/datacom applications. 60 brochure Complete line of switches and circuit breakers specific for industrial automation & controls applications. www.carlingtech.com Reps & Contact Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications www.carlingtech.com 61 Worlwide Headquarters Asia-Pacific Headquarters 60 Johnson Avenue, Plainville, CT 06062 Tel: (860) 793-9281 Fax: (860) 793-9231 Email: [email protected] Web: www.carlingtech.com Kowloon, Hong Kong Tel: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Carling Technologies, Inc. Northern Region Sales Office Carling Technologies, Asia-Pacific Ltd. Shenzhen, China [email protected] Europe/Middle East/ Africa Headquarters Carling Technologies Ltd. 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Tel: Int + 44 1392-364422 Fax: Int + 44 1392-364477 Email: [email protected] [email protected] Shanghai, China [email protected] Pune, India Germany [email protected] Kaohsiung, Taiwan France [email protected] Yokohama, Japan Southeast Region Sales Office Midwest Region Sales Office West Region Sales Office Latin America Sales Office [email protected] RE NEWABL E ENERG Y- C_04_2016 [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]