A-Series Circuit Breaker Datasheet [pdf]

A-Series
A-Series
CIRCUIT BREAKER
Well known for their proven reliability, Carling Technologies’ A-Series hydraulic magnetic circuit breakers are
compact, temperature stable and designed for precision operation in OEM markets requiring general purpose
as well as full load amp applications. When front panel operation and aesthetics demand a clean, contemporary
design, the visi-rocker or paddle actuators are ideally suitable. A sealed toggle actuator style is also available and
ideal for harsh environment applications requiring additional sealing protection. Optional rocker-guard and pushto-reset bezels, which help prevent inadvertent actuation, are also available.
1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL Recognized, UL Listed, UL1500, UL1077,
TUV, VDE & CSA
Product Highlights:
Up to 50 amps in a compact size
Various actuator styles
ŠŠ Sealed metal toggle option tested to
MIL-PRF-55629C. Meets IP68
Requirements
Typical Applications:
Telecom/Datacom
Marine
ŠŠ Military
ŠŠ Renewable Energy
ŠŠ Generators & Welder
ŠŠ
ŠŠ
ŠŠ
ŠŠ
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
2 | A-Series Circuit Breaker - General Specifications
Electrical
Maximum Voltage
Current Ratings
Standard Voltage Coils
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings
available - consult ordering scheme.
DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme.
SPDT; 10.1 A - 250VAC,
1.0 A-65VDC/0.5 A - 80 VDC,
0.1A - 125VAC (with gold contacts).
Minimum: 100 Megohms at 500 VDC
UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805.
Values from Line to Load Terminal - based on Series Trip Circuit Breaker.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
CURRENT
TOLERANCE
(AMPS)
(%)
0.10 - 5.0
5.1 - 20.0
15
25
20.1 - 50.0
35
Pulse Tolerance Curves
Mechanical
Endurance
Trip Free
Trip Indication
Physical
Number of Poles
Internal Circuit Config.
Weight
Standard Colors
10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.
All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position.
The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped.
1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps.
Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch.
Approximately 65 grams/pole. (Approximately 2.32 ounces/pole)
Housing - Black; Actuator- See Ordering Scheme.
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current.
Vibration
Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current.
Moisture Resistance
Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH.
Salt Spray
Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C).
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector.
A-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Voltage
Circuit
Configuration
Series
Max
Rating
Current Rating
Load
Frequency Phase Full
Amps
32
65
DC
DC
-----
80
DC
---
125
125
125
125 / 250
125 / 250
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
1
1
14
13
13
1
250
50 / 60
14
3
Dual Coil
277
32
65
50 / 60
DC
DC
1
-----
80
DC
---
125
50 / 60
1
125
125 / 250
125 / 250
50 / 60
50 / 60
50 / 60
14
13
13
1
1
1
14
250
50 / 60
3
Shunt
Relay
Switch Only
277
80
125 / 250
50 / 60
DC
50 / 60
250
50 / 60
277
80
125 / 250
50 / 60
DC
50 / 60
250
50 / 60
277
65
80
50 / 60
DC
DC
250
50 / 60
277
50 / 60
1
--1
1
3
1
--13
1
3
1
----1
3
1
0.02 - 15
31 - 50
0.02 - 30
--0.02 - 30
1 - 50
1 - 50
0.02 - 30
0.02 - 50
0.02 - 30
0.02 - 30
--1 - 50
0.02 - 30
31 - 50
0.02 - 30
0.02 - 50
0.02 - 50
0.02 - 30
--0.02 - 30
1 - 50
0.02 - 30
0.02 - 30
0.02 - 50
0.02 - 30
0.02 - 30
--1 - 50
0.02 - 30
31 - 50
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 50
0.02 - 30
--0.02 - 50
0.02 - 30
General
Purpose
Amps
------31 - 50
----------------------------31 - 50
--------------31 - 50
--------------------------------31 - 50
--31 - 50
Short Circuit Capacity (Amps)
UL / CSA
With Backup
Without
Fuse
Backup Fuse
--5000
--7500
--7500
--7500
--3000
--2000
--1000
--3000
--3000
--1500
--3000
--3000
--1000
5000 2
--2000 1
--5000 1
----5000
--7500
--7500
--7500
--3000
--2000
--1000
--3000
--3000
--1500
--3000
--3000
--1000
5000 2
--2000 1
--5000 1
----7500
--3000
--3000
5000 2
--5000 1
----7500
--3000
--3000
5000 2
--5000 1
---
Application Codes
UL
CSA
TC1, OL1, U2
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, 2, OL1, U2
TC1, 2, OL1, U2
TC1, 2, OL0, U2
TC1, OL1, U2
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, OL1, U2
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, 2, OL1, U1
TC1, 2, OL1, U2
TC1, OL0, U2
TC1, OL1, U2
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, OL1, U2
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, OL1, U2
TC3, OL1, U3
TC1, 2, OL1, U2
TC1, 2, OL1, U2
TC1, 2, OL0, U2
TC1, OL1, U2
TC1, 2, OL0, U1
TC3, OL1, U3
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, OL1, U2
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, OL1, U2
TC1, OL1, U2
TC3, OL1, U3
TC1, 2, OL1, U1
TC1, 2, OL1, U2
TC1, OL0, U2
TC1, OL1, U2
TC1, 2, OL0, U1
TC3, OL1, U3
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
TC1, 2, OL1, C1
TC1, 2, OL1, C1
not applicable
Notes:
1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
2 Same as note 1, except that backup fuse is limited to 80 A maximum.
3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System.
4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Construction
Notes
Rocker Version
Rocker Version
Handle
Single Pole Break
Two Pole Break
Rocker Version
Rocker Version
Single Pole Break
Two Pole Break
4 | A-Series Circuit Breaker - General Specifications
Electrical Tables
Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component
Supplementary Protector.
1
3
2
3
2
3
2
Notes:
1 General Purpose Ratings for UL/CSA Only.
2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
3 Same as note 2, except that backup fuse is limited to 80 A maximum.
4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - General Specifications | 5
Electrical Tables
Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine
Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices,
Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
A-SERIES TABLE C: UL1500 (Marine Ignition Protected)
VOLTAGE
CIRCUIT
CONFIGURATION
CURRENT
RATING
SHORT CIRCUIT
CAPACITY (AMPS)
APPLICATION CODES
MAX. RATING
FREQUENCY
PHASE
FULL LOAD AMPS
WITHOUT BACKUP
FUSE
UL
CSA
14 1
DC
---
0.02 - 50
5000
TC1,OL1,U1
TC1,OL1,U1
32 1
65
DC
---
0.02 - 50
5000
TC1,OL1,U2
TC1,OL1,U2
DC
---
0.02 - 50
3000
TC1,OL1,U1
TC1,OL1,U1
125
50 / 60
1
0.02 - 50
3000
TC1,OL1,U2
TC1,OL1,U2
125 / 250
50 / 60
12
0.02 - 50
3000
TC1,OL1,U2
TC1,OL1,U2
250
50 / 60
1
0.02 - 30
1500
TC1,OL1,U1
TC1,OL1,U1
SERIES
Notes:
Notes:
1 Available with
special catalog number only (consult factory).
2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system
1 Available with Special Catalog Number Only (consult factory)
2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
Notes:
1 Parallel Pole Construction
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
CSA Accepted
Component Supplementary
Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
TUV Certified
EN60934, under License No. R72103448
UL Standard 1500
Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection
VDE Certified
EN60934, VDE 0642 under File
No. 10537
UL Listed
UL Standard 489A
Communications Equipment
(Guide CCN/DITT, File E189195)
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
6 | A-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme
A A 3
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
10
450
6
Frequency
& Delay
7
Current Rating
1 SERIES
A
C
10
Mounting/
Barriers
11
Agency
Approval
7 CURRENT RATING (AMPERES)
CODEAMPERES
2 ACTUATOR 1
A
Handle, one per pole
B
Handle, one per multipole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
1 B 1
8
9
Terminal Actuator
Color
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
A 2 Switch Only (No Coil)
F 3
B
Series Trip (Current)
G 3
C
Series Trip (Voltage)
H 3,4
D 3 Shunt Trip (Current)
3
E
Shunt Trip (Voltage)
K 3,4
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH 5 5 0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
7
2
S.P.D.T., 0.110 Q.C. Term.
4 S.P.D.T., 0.110 Q.C. Term.
8
(Gold Contacts)
9
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 7 50/60Hz Short, Hi-Inrush
44 7 50/60Hz Medium, Hi-Inrush
46 7 50/60Hz Long, Hi-Inrush
52 7 DC, Short,Hi-Inrush
54 7 DC, Medium, Hi-Inrush
56 7 DC, Long, Hi-Inrush
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
4 pole - two handles at center poles
5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
select Current Code 630. For 35 - 50 amps, select Current Code 650.
3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with
standard half shells. 35-50A - supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
6 Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers.
9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q..
10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat
Washers. These breakers are only VDE Certified when the washers are used.
12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A.
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit
Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are
available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C.
14 Terminal Code Q not available with VDE certification.
15 Single pole only.
0200.020
2250.250
4202.000
0250.025
2300.300
5222.250
0300.030
2350.350
5272.750
0350.035
2400.400
4303.000
0400.040
2450.450
4353.500
0450.045
2500.500
4404.000
0500.050
2550.550
4454.500
0550.055
2600.600
4505.000
0600.060
2650.650
4555.500
0650.065
2700.700
4606.000
0700.070
2750.750
4656.500
0750.075
2800.800
4707.000
0800.080
2850.850
4757.500
0850.085
2900.900
4808.000
0900.090
2950.950
4858.500
0950.095
4101.000
4909.000
2100.100
5121.250
4959.500
2150.150
4151.500
610 10.000
2200.200
517 1.750
71010.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 835.000
640 840.000
645 845.000
650 850.000
CODEAMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65 65 AC
K20 120 AC
L40 240 AC
8 TERMINAL 9
1 10 Push-On 0.250 Tab (Q.C.)
E 11 Screw M4 (Bus Type)
2
Screw 8-32 with upturned lugs F Screw M5 with upturned lugs
11
3
Screw 8-32 (Bus Type)
& 30° bend
4
Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
11
11
5
Screw 10-32 (Bus Type)
H Screw M5 (Bus Type)
6
Screw 8-32 with upturned lugs L 12 0.250 Q.C./ Solder Lug
& 30° bend
M 11 M6 Threaded Stud
7
Screw 8-32 (Bus Type) Q 14Push-In Stud
& 30° bend
R Screw M4 with upturned lugs
8
Screw 10-32 with upturned lugs & 30° bend
& 30° bend
T 11 Screw M4 (Bus Type)
9
Screw 10-32 (Bus Type) & 30° bend
& 30° bend
P 13 Printed Circuit Board Terminals
B Screw M5 with upturned lugs
S 13 Push-On 0.110 Tab (Q.C.)
C Screw M4 with upturned lugs
9 ACTUATOR COLOR & LEGEND
Actuator Color
I-O
ON-OFF
White
AB
Black
CD
Red
FG
Green
HJ
Blue
KL
Yellow
MN
Gray
PQ
Orange
RS
Black (short handle)15 TU
Dual
Legend Color
1Black
2White
3White
4White
5White
6Black
7Black
8Black
9White
10 MOUNTING / BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
1 6-32 x 0.195 inches
A 6-32 x 0.195 inches
2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5 without Handleguard
6 without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7 without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
D VDE Certified, UL Recognized & CSA Accepted
E TUV Certified, UL Recognized & CSA Accepted
I
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Handle UL489A – Ordering Scheme | 7
A A 1
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
14
450
6
Frequency
& Delay
7
Current Rating
2 ACTUATOR 1
A
Handle, one per pole
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES 2
1
One
2
Two
3
Three
4
Four
4 CIRCUIT
B
Series Trip (Current)
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52 3 DC, Short,Hi-Inrush
54 3 DC, Medium, Hi-Inrush
56 3 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODEAMPERES
2100.100
2150.150
2200.200
2250.250
2300.300
2350.350
2400.400
2450.450
2500.500
2550.550
2600.600
2650.650
2700.700
2750.750
2800.800
2850.850
2900.900
2950.950
4101.000
5121.250
4151.500
517 1.750
4202.000
5222.250
5272.750
4303.000
4353.500
4404.000
4454.500
4505.000
4555.500
4606.000
4656.500
4707.000
4757.500
4808.000
4858.500
4909.000
4959.500
610 10.000
71010.500
611 11.000
71111.500
61212.000
71212.500
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
M T
11
Max. Appl.
Rating
12
Agency
Approval
9 ACTUATOR COLOR & LEGEND
Actuator Color
ON-OFF
Dual
Legend Color
White
B1 Black
Black
D2 White
Red
G3White
Green
J4White
Blue
L5White
Yellow
N6Black
Gray
Q7Black
Orange
S8Black
Black (short handle) 10 U9White
1 SERIES
A
5 AUXILIARY/ALARM SWITCH 2
7
0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
8
2
S.P.D.T., 0.110 Q.C. Term.
9
1 B 1
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 335.000
640 340.000
645 345.000
650 350.000
8 TERMINAL 5
1 6 Push-On 0.250 Tab (Q.C.)
9 Screw 10-32 (Bus Type)
2 Screw 8-32 with upturned lugs
& 30° bend
3 7 Screw 8-32 (Bus Type)
B Screw M5 with upturned lugs
4 Screw 10-32 with upturned lugs
F Screw M5 with upturned lugs
5 7 Screw 10-32 (Bus Type)
& 30° bend
6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
& 30° bend
H Screw M5 (Bus Type)
7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud
& 30° bend
P 8 Printed Circuit Board Terminals
8 Screw 10-32 with upturned lugs Q 9 Push-In Stud
& 30° bend
10 MOUNTING / BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
1 6-32 x 0.195 inches
A 6-32 x 0.195 inches
2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5 without Handleguard
6 without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7 without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
K
UL489A Listed, VDE Certified
J
UL489A Listed, TUV Certified
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker.
2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
3 VDE Certified to 30 amps. UL489A Listed to 50 amps.
4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers.
5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
30 amps with VDE Certification and 50 amps with UL489A Listing.
9 Terminal Code Q not available with VDE certification.
10 Single pole only.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
8 | A-Series Circuit Breaker - Handle WORLD – Ordering Scheme
A A 3
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
14
450
6
Frequency
& Delay
7
Current Rating
1 SERIES
A
2 ACTUATOR 1
A
Handle, one per pole
B
Handle, one per multipole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
3
4
Three
Four
5
6
4 CIRCUIT
A 2 Switch Only (No Coil)
D 3
B
Series Trip (Current)
E 3
C
Series Trip (Voltage)
H 3,4
Five
Six
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH 5
0
without Aux Switch
2
S.P.D.T., 0.110 Q.C. Term.
4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts)
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 7 50/60Hz Short, Hi-Inrush
44 7 50/60Hz Medium, Hi-Inrush
46 7 50/60Hz Long, Hi-Inrush
52 7 DC, Short,Hi-Inrush
54 7 DC, Medium, Hi-Inrush
56 7 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
1 A 1
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
P
11
Agency
Approval
8 TERMINAL 9
1 10 Push-On 0.250 Tab (Q.C.)
B Screw M5 with upturned lugs
2
Screw 8-32 with upturned lugs C Screw M4 with upturned lugs
3 11 Screw 8-32 (Bus Type)
E 11 Screw M4 (Bus Type)
4
Screw 10-32 with upturned lugs F Screw M5 with upturned lugs
5 11 Screw 10-32 (Bus Type)
& 30° bend
6
Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
11
& 30° bend
H Screw M5 (Bus Type)
7
Screw 8-32 (Bus Type) R Screw M4 with upturned lugs
& 30° bend
& 30° bend
8
Screw 10-32 with upturned lugs T 11 Screw M4 (Bus Type)
& 30° bend
& 30° bend
9
Screw 10-32 (Bus Type)
& 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator Color
I-O
Dual
Legend Color
White
A1 Black
Black
C2 White
Red
F3White
Green
H4White
Blue
K5White
Yellow
M6Black
Gray
P7Black
Orange
R8Black
15
Black (short handle) T9White
10 MOUNTING / BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
1 6-32 x 0.195 inches
A 6-32 x 0.195 inches
2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5 without Handleguard
6 without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7 without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
CODEAMPERES
2100.100
2850.850
4555.500
2150.150
2900.900
4606.000
2200.200
2950.950
4656.500
2250.250
4101.000
4707.000
2300.300
5121.250
4757.500
2350.350
4151.500
4808.000
2400.400
517 1.750
4858.500
2450.450
4202.000
4909.000
2500.500
5222.250
4959.500
2550.550
5272.750
610 10.000
2600.600
4303.000
71010.500
2650.650
4353.500
611 11.000
2700.700
4404.000
71111.500
2750.750
4454.500
61212.000
2800.800
4505.000
71212.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 835.000
640 840.000
645 845.000
650 850.000
CODEAMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65 65 AC
K20 120 AC
L40 240 AC
11 AGENCY APPROVAL
P TUV Certified, UL Recognized & CSA Accepted
Q UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
6 Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.
7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8 Available up to two poles with AC or DC delays.
9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G and H.
10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers.
These breakers are only TUV Certified when the washers are used.
12 Single pole only.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Rocker UL489A – Ordering Scheme | 9
A F 1
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
14
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR 1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
Single color
J Vertical legend
K Horizontal legend
Push-To-Reset, Visi-Rocker
N Indicate OFF, vertical legend
O Indicate OFF, horizontal legend
Push-To-Reset , Single color
R Vertical legend
U Horizontal legend
450
7
Current Rating
1 3 1
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
M T
11
Max. Appl.
Rating
12
Agency
Approval
8 TERMINAL 5
1 6 Push-On 0.250 Tab (Q.C.)
9 Screw 10-32 (Bus Type)
2 Screw 8-32 with upturned lugs
& 30° bend
7
3 Screw 8-32 (Bus Type)
B Screw M5 with upturned lugs
4 Screw 10-32 with upturned lugs
F Screw M5 with upturned lugs
5 7 Screw 10-32 (Bus Type)
& 30° bend
6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
& 30° bend
H Screw M5 (Bus Type)
7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud
& 30° bend
P 8 Printed Circuit Board Terminals
8 Screw 10-32 with upturned lugs Q 9 Push-In Stud
& 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color 10 ON-OFFDual 10 Single Color Visi-Rocker
White
B1Black White
Black
D2Whiten/a
Red
G3WhiteRed
Green
J4WhiteGreen
Blue
L5WhiteBlue
Yellow
N6Black Yellow
Gray
Q7Black Gray
Orange
S8Black Orange
3 POLES 2
1
One
2
Two
3
Three
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY / ALARM SWITCH 2
7
0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
8
2
S.P.D.T., 0.110 Q.C. Term.
9
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52 DC, Short,Hi-Inrush
54 DC, Medium, Hi-Inrush
56 DC, Long, Hi-Inrush
CODEAMPERES
2850.850
2900.900
2950.950
4101.000
5121.250
4151.500
517 1.750
4202.000
5222.250
5272.750
4303.000
4353.500
4404.000
4454.500
4505.000
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
K
UL489A Listed, VDE Certified
J
UL489A Listed, TUV Certified
7 CURRENT RATING (AMPERES)
2100.100
2150.150
2200.200
2250.250
2300.300
2350.350
2400.400
2450.450
2500.500
2550.550
2600.600
2650.650
2700.700
2750.750
2800.800
10 MOUNTING / BARRIERS 11
STANDARD ROCKER BEZEL
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm no
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm no
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
without Rockerguard (single pole units only)
no
H
with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
9
without Rockerguard (single pole units only)
no
J
with Rockerguard (single pole units only)
no
4555.500
4606.000
4656.500
4707.000
4757.500
4808.000
4858.500
4909.000
4959.500
610 10.000
71010.500
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 435.000
640 440.000
645 445.000
650 450.000
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers.
5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing.
9 Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes
N & O. Rockerguard available with actuator codes C through K
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
10 | A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 11
Circuit & Terminal Diagrams: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 Alarm Switch available with .110 x .020 QC & solder lug terminals only.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
12 | A-Series Circuit Breaker - Handle - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ± 0.20 [.51] unless otherwise specified.
3 For agency code P = .150 [3.81].
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 5 - Dimensional Specifications | 13
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Recommended panel thickness: .040 [1.02] to .100 [2.54].
3 Tolerance ±.020 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
14 | A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 7 - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Recommended panel thickness: .040 [1.02] to .100 [2.54].
3 Tolerance ±.020 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme | 15
A M 1
1
Series
2
Actuator
3
Poles
B 0
4
Circuit
5
Aux/Alarm
Switch
10
450
6
Frequency
& Delay
7
Current Rating
1 SERIES
A
2 ACTUATOR 1
M Sealed Toggle, one per unit
3 POLES
1
One
2
Two
3
Three
4 CIRCUIT
A 2 Switch Only (No Coil)
F 3
B
Series Trip (Current)
G 3
C
Series Trip (Voltage)
H 3,4
D 3 Shunt Trip (Current)
E 3 Shunt Trip (Voltage)
K 3,4
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH 5 5 0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
7
2
S.P.D.T., 0.110 Q.C. Term.
4 S.P.D.T., 0.110 Q.C. Term.
8
(Gold Contacts)
9
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 7 50/60Hz Short, Hi-Inrush
44 7 50/60Hz Medium, Hi-Inrush
46 7 50/60Hz Long, Hi-Inrush
52 7 DC, Short,Hi-Inrush
54 7 DC, Medium, Hi-Inrush
56 7 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODEAMPERES
0200.020
0250.025
0300.030
0350.035
0400.040
0450.045
0500.050
0550.055
0600.060
0650.065
0700.070
0750.075
0800.080
0850.085
0900.090
0950.095
2100.100
2150.150
2200.200
2250.250
2300.300
2350.350
2400.400
2450.450
2500.500
2550.550
2600.600
2650.650
2700.700
2750.750
2800.800
2850.850
2900.900
2950.950
4101.000
5121.250
4151.500
517 1.750
4202.000
5222.250
425 2.500
5272.750
4303.000
4353.500
4404.000
4454.500
4505.000
4555.500
4606.000
4656.500
4707.000
4757.500
4808.000
4858.500
4909.000
4959.500
610 10.000
71010.500
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 835.000
640 840.000
645 845.000
650 850.000
1 0 1
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
8 TERMINAL 9
1 10 Push-On 0.250 Tab (Q.C.)
E Screw M4 (Bus Type)
2
Screw 8-32 with upturned lugs F Screw M5 with upturned lugs
3
Screw 8-32 (Bus Type)
& 30° bend
4
Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
5
Screw 10-32 (Bus Type)
H Screw M5 (Bus Type)
6
Screw 8-32 with upturned lugs L 12 0.250 Q.C./ Solder Lug
& 30° bend
M M6 Threaded Stud
7
Screw 8-32 (Bus Type) Q Push-In Stud
& 30° bend
R Screw M4 with upturned lugs
8
Screw 10-32 with upturned lugs & 30° bend
& 30° bend
T Screw M4 (Bus Type)
9
Screw 10-32 (Bus Type) & 30° bend
& 30° bend
P 12 Printed Circuit Board Terminals
B Screw M5 with upturned lugs
S Push-On 0.110 Tab (Q.C.)
C Screw M4 with upturned lugs
9 LEGEND PLATE
0
No legend plate
10 MOUNTING / BARRIERS
MOUNTING STYLEBARRIERS
1
Standard Hex Nut
no
A
Standard Hex Nut (multipole only)
yes
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
I
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Notes:
1 Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole
3 pole - center pole
2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a
protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps,
select Current Code 650.
3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8 UL Recognition and CSA Certification available on one and two pole breakers.
9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over
30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q.
10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not
recommended over 20 amps.
11 Terminal Code L : available up to 30A.
12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6
CODEAMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
C
11
Agency
Approval
J65 65 AC
K20 120 AC
L40 240 AC
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
16 | A-Series Circuit Breaker - Sealed Toggle - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 17
A F 1
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
24
630
6
Frequency
& Delay
7
Current Rating
2 3 1
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
D
11
Agency
Approval
7 CURRENT RATING (AMPERES)
1 SERIES
A
CODEAMPERES
0200.020
2250.250
4202.000
0250.025
2300.300
5222.250
0300.030
2350.350
5272.750
0350.035
2400.400
4303.000
0400.040
2450.450
4353.500
0450.045
2500.500
4404.000
0500.050
2550.550
4454.500
0550.055
2600.600
4505.000
0600.060
2650.650
4555.500
0650.065
2700.700
4606.000
0700.070
2750.750
4656.500
0750.075
2800.800
4707.000
0800.080
2850.850
4757.500
0850.085
2900.900
4808.000
0900.090
2950.950
4858.500
0950.095
4101.000
4909.000
2100.100
5121.250
4959.500
2150.150
4151.500
610 10.000
2200.200
517 1.750
71010.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8
2 ACTUATOR 1
Two Color Visi-Rocker
C
Indicate ON, vertical legend
D
Indicate ON, horizontal legend
F
Indicate OFF, vertical legend
G
Indicate OFF, horizontal legend
H
Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N
Indicate OFF, vertical legend
O
Indicate OFF, horizontal legend
P
Indicate OFF, no legend
Single color
J
Vertical legend
K
Horizontal legend
L
No legend
Push-To-Reset , Single color
R
Vertical legend
U
Horizontal legend
V
No legend
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 835.000
640 840.000
645 845.000
650 850.000
CODEAMPERES
3 POLES
1
One
2
Two
3
Three
4 CIRCUIT
F 4
A 3 Switch Only (No Coil)
G 4
B
Series Trip (Current)
H 4,5
C
Series Trip (Voltage)
4
D
Shunt Trip (Current)
K 4,5
E 4 Shunt Trip (Voltage)
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH 6,7 5 0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
7
2
S.P.D.T., 0.110 Q.C. Term.
4 S.P.D.T., 0.110 Q.C. Term.
8
(Gold Contacts)
9
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 9 50/60Hz Short, Hi-Inrush
44 9 50/60Hz Medium, Hi-Inrush
46 9 50/60Hz Long, Hi-Inrush
52 9 DC, Short,Hi-Inrush
54 9 DC, Medium, Hi-Inrush
56 9 DC, Long, Hi-Inrush
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed
poles, and have one rocker per breaker.
3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole
(Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5 Consult factory for Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA
minimum power to trip and are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted
& TUV Certified to 50 amps.
10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only.
UL Recognition & CSA Accepted available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only
available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30
amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M
(M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE
Certified when the washers are used.
14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with
VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B & C.
Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with
UL Recognition and CSA Certification with Circuit Codes A, B and C.
16 Terminal Code Q not available with VDE.
17 Terminal Code S used on voltage coil circuit constructions only.
18 Color shown is visi and legend with remainder of rocker black.
19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on
Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O.
Rockerguard available with actuator codes C through L.
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65 65 AC
K20 120 AC
L40 240 AC
8 TERMINAL 11
1 12 Push-On 0.250 Tab (Q.C.)
E 13 Screw M4 (Bus Type)
2
Screw 8-32 with upturned lugs F Screw M5 with upturned lugs
13
3
Screw 8-32 (Bus Type)
& 30° bend
4
Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
H 13 Screw M5 (Bus Type)
5 13 Screw 10-32 (Bus Type)
6
Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug
& 30° bend
M 13M6 Threaded Stud
7
Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals
& 30° bend
Q 16Push-In Stud
8
Screw 10-32 with upturned lugs R Screw M4 with upturned lugs
& 30° bend
& 30° bend
9
Screw 10-32 (Bus Type) S 17 Push-On 0.110 Tab (Q.C.) & 30° bend
& 30° bend
B Screw M5 with upturned lugs
T Screw M4 (Bus Type)
C Screw M4 with upturned lugs & 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color 12 ON-OFFDual 12 Single Color Visi-Rocker
White
B1Black White
Black
D2Whiten/a
Red
G3WhiteRed
Green
J4WhiteGreen
Blue
L5WhiteBlue
Yellow
N6Black Yellow
Gray
Q7Black Gray
Orange
S8Black Orange
10 MOUNTING / BARRIERS 20
STANDARD ROCKER BEZEL
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm no
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm no
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
without Rockerguard (single pole units only)
no
H
with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
9
without Rockerguard (single pole units only)
no
J
with Rockerguard (single pole units only)
no
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
18 | A-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme
A 1 1
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
24
630
6
Frequency
& Delay
7
Current Rating
2 ACTUATOR 1
Two Color Visi-Rocker
1
Indicate OFF, vertical legend
2
Indicate OFF, horizontal legend
Single color
3
Vertical legend
4
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF, vertical legend
6
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
Vertical legend
8
Horizontal legend
2
Two
3
Three
4 CIRCUIT
F 4
A 3 Switch Only (No Coil)
G 4
B
Series Trip (Current)
H 4,5
C
Series Trip (Voltage)
4
D
Shunt Trip (Current)
K 4,5
E 4 Shunt Trip (Voltage)
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY / ALARM SWITCH 6,7 5 0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
7
2
S.P.D.T., 0.110 Q.C. Term.
4 S.P.D.T., 0.110 Q.C. Term.
8
(Gold Contacts)
9
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 6 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 6 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 9 50/60Hz Short, Hi-Inrush
44 9 50/60Hz Medium, Hi-Inrush
46 9 50/60Hz Long, Hi-Inrush
52 9 DC, Short,Hi-Inrush
54 9 DC, Medium, Hi-Inrush
56 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODEAMPERES
0200.020
2250.250
4202.000
0250.025
2300.300
5222.250
0300.030
2350.350
5272.750
0350.035
2400.400
4303.000
0400.040
2450.450
4353.500
0450.045
2500.500
4404.000
0500.050
2550.550
4454.500
0550.055
2600.600
4505.000
0600.060
2650.650
4555.500
0650.065
2700.700
4606.000
0700.070
2750.750
4656.500
0750.075
2800.800
4707.000
0800.080
2850.850
4757.500
0850.085
2900.900
4808.000
0900.090
2950.950
4858.500
0950.095
4101.000
4909.000
2100.100
5121.250
4959.500
2150.150
4151.500
610 10.000
2200.200
517 1.750
71010.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 835.000
640 840.000
645 845.000
650 850.000
CODEAMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
9
Actuator
Color
10
Mounting/
Barriers
E
11
Agency
Approval
8 TERMINAL 11
1 12 Push-On 0.250 Tab (Q.C.)
E 13 Screw M4 (Bus Type)
2
Screw 8-32 with upturned lugs F Screw M5 with upturned lugs
3 13 Screw 8-32 (Bus Type)
& 30° bend
4
Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
13
13
Screw 10-32 (Bus Type)
H Screw M5 (Bus Type)
5
6
Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug
& 30° bend
M 13M6 Threaded Stud
7
Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals
& 30° bend
Q Push-In Stud
8
Screw 10-32 with upturned lugs R Screw M4 with upturned lugs
& 30° bend
& 30° bend
9
Screw 10-32 (Bus Type) S 16 Push-On 0.110 Tab (Q.C.) & 30° bend
& 30° bend
B Screw M5 with upturned lugs
T Screw M4 (Bus Type)
C Screw M4 with upturned lugs & 30° bend
1 SERIES
A
3 POLES 2
1
One
2 3 1
8
Terminal
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
J65 65 AC
K20 120 AC
L40 240 AC
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color 17 ON-OFFDual 17 Single Color Visi-Rocker
White
B1Black White
Black
D2Whiten/a
Red
G3WhiteRed
Green
J4WhiteGreen
Blue
L5WhiteBlue
Yellow
N6Black Yellow
Gray
Q7Black Gray
Orange
S8Black Orange
10 MOUNTING / BARRIERS 18
STANDARD ROCKER BEZEL
BARRIERS
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm no
B
ISO M3 x 5mm (multi-pole units only)
yes
19
RECESSED OFF SIDE ROCKER ACTUATOR
5
6-32 x 0.195 inches
no
E
6-32 x 0.195 inches (multi-pole units only)
yes
6
ISO M3 x 5mm no
F
ISO M3 x 5mm (multi-pole units only)
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm no
D
ISO M3 x 5mm (multi-pole units only)
yes
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker.
3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt
construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA
minimum power to trip and are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used.
14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL
Recognition and CSA Accepted with Circuit Codes A, B and C.
16 Terminal Code S used on voltage coil circuit constructions only.
17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6.
19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Flat Rocker UL 489A – Ordering Scheme | 19
A 1 1
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Aux/Alarm
Switch
14
630
6
Frequency
& Delay
7
Current Rating
2 ACTUATOR 1
Two Color Visi-Rocker
1
Indicate OFF, vertical legend
2
Indicate OFF, horizontal legend
Single color
3
Vertical legend
4
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF, vertical legend
6
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
Vertical legend
8
Horizontal legend
2
Two
3
Three
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY / ALARM SWITCH 3 7 0
without Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
8
2
S.P.D.T., 0.110 Q.C. Term.
9
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52 DC, Short,Hi-Inrush
54 DC, Medium, Hi-Inrush
56 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODEAMPERES
0200.020
0250.025
0300.030
0350.035
0400.040
0450.045
0500.050
0550.055
0600.060
0650.065
0700.070
0750.075
0800.080
0850.085
0900.090
0950.095
2100.100
2150.150
2200.200
2250.250
2300.300
2350.350
2400.400
2450.450
2500.500
2550.550
2600.600
2650.650
2700.700
2750.750
2800.800
2850.850
2900.900
2950.950
4101.000
5121.250
4151.500
517 1.750
9
Actuator
Color
10
Mounting/
Barriers
M T
11
Max. Appl.
Rating
12
Agency
Approval
8 TERMINAL 5
1 6 Push-On 0.250 Tab (Q.C.)
9 Screw 10-32 (Bus Type)
2 Screw 8-32 with upturned lugs
& 30° bend
3 7 Screw 8-32 (Bus Type)
B Screw M5 with upturned lugs
4 Screw 10-32 with upturned lugs
F Screw M5 with upturned lugs
5 7 Screw 10-32 (Bus Type)
& 30° bend
6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend
& 30° bend
H Screw M5 (Bus Type)
7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud
& 30° bend
P 8 Printed Circuit Board Terminals
8 Screw 10-32 with upturned lugs Q 9 Push-In Stud
& 30° bend
1 SERIES
A
3 POLES 2
1
One
2 3 1
8
Terminal
4202.000
5222.250
5272.750
4303.000
4353.500
4404.000
4454.500
4505.000
4555.500
4606.000
4656.500
4707.000
4757.500
4808.000
4858.500
4909.000
4959.500
610 10.000
71010.500
611 11.000
71111.500
61212.000
71212.500
61313.000
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 435.000
640 440.000
645 445.000
650 450.000
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color 11 ON-OFFDual 11 Single Color Visi-Rocker
White
B1Black White
Black
D2Whiten/a
Red
G3WhiteRed
Green
J4WhiteGreen
Blue
L5WhiteBlue
Yellow
N6Black Yellow
Gray
Q7Black Gray
Orange
S8Black Orange
10 MOUNTING / BARRIERS 12
STANDARD ROCKER BEZEL
BARRIERS
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm no
B
ISO M3 x 5mm (multi-pole units only)
yes
RECESSED OFF SIDE ROCKER ACTUATOR
5
6-32 x 0.195 inches
no
E
6-32 x 0.195 inches (multi-pole units only)
yes
6
ISO M3 x 5mm no
F
ISO M3 x 5mm (multi-pole units only)
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm no
D
ISO M3 x 5mm (multi-pole units only)
yes
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
J
UL489A Listed, TUV Certified
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers.
5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing.
9 Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
12 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator
codes N & O. Rockerguard available with actuator codes C through K
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
20 | A-Series Circuit Breaker - Recessed Paddle – Ordering Scheme
A Y 2
1
Series
2
Actuator
B 0
4
Circuit
3
Poles
5
Auxiliary
Switch
24
620
6
Frequency
& Delay
7
Current Rating
1 SERIES
A
2 ACTUATOR 1
Y
Single Color Recessed Paddle Actuator with Vertical Legends
3 POLES 2
1
One
2
4 CIRCUIT
A Switch-Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D Shunt Trip (Current)
E Shunt Trip (Voltage)
Two
F
G
H
K
3
Three
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip Voltage Coil
Dual Coil with Shunt Trip Current Coil
5 AUXILIARY SWITCH 0
without Aux Switch
1
S.P.D.T. with 0.093 Q.C. Terminals
2
S.P.D.T. with 0.110 Q.C. Terminals
3 S.P.D.T. with 0.139 Solder Lug Terminals
4 S.P.D.T. with 0.110 Q.C. Terminals (Gold Contacts)
5 S.P.D.T. with 0.093 Q.C. Terminals (Gold Contacts)
6 S.P.S.T.-N.O. with 0.139 Solder Lug Terminals
7 S.P.S.T.-N.O. with 0.110 Q.C. Terminals (Gold Contacts)
8
S.P.S.T.-N.O. with 0.187 Q.C. Terminals
9 S.P.D.T. with 0.187 Q.C. Terminals
6 FREQUENCY & DELAY 3
3
DC, 50/60 Hz Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60 Hz Instantaneous
21 50/60 Hz Ultra Short
22 24 26 42 44 46 52 54 56 50/60 Hz Short
50/60 Hz Medium
50/60 Hz Long
50/60 Hz Short Hi-Inrush
50/60 Hz Medium Hi-Inrush
50/60 Hz Long Hi-Inrush
DC, Short, Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES) 4
CODEAMPERES
2200.200
2950.950
4606.000
2250.250
4101.000
4656.500
2300.300
5121.250
4707.000
2350.350
4151.500
4757.500
2400.400
517 1.750
4808.000
2450.450
4202.000
4858.500
2500.500
5222.250
4909.000
2550.550
4252.500
4959.500
2600.600
5272.750
610 10.000
2650.650
4303.000
71010.500
2700.700
4353.500
611 11.000
2750.750
4404.000
71111.500
2800.800
4454.500
61212.000
2850.850
4505.000
71212.500
2900.900
4555.500
61313.000
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
61414.000
61515.000
61616.000
61717.000
61818.000
62020.000
62222.000
62424.000
62525.000
63030.000
635 35.000
640 40.000
645 45.000
65050.000
4 2 1
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
8 TERMINAL
1 Push-On 0.250 Tab (Q.C.)
C
2 Screw 8-32 with upturned lugs
E
3 Screw 8-32 (Bus Type)
F
4 Screw 10-32 with upturned lugs
5 Screw 10-32 (Bus Type)
G
6 Screw 8-32 with upturned lugs H
& 30° bend
L
7 Screw 8-32 (Bus Type) M
& 30° bend
P
8 Screw 10-32 with upturned lugs Q
& 30° bend
R
9 Screw 10-32 (Bus Type)
& 30° bend
S
B Screw M5 with upturned lugs
T
A32 32 DC
A48 48 DC
A65 65 DC
J06
6 AC
J12
J18
J24
J48
12 AC
18 AC
24 AC
48 AC
12
Agency
Approval
Screw, M4 with upturned lugs
Screw, M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./Solder Lug
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
Screw, M4 with upturned lugs
& 30° Bend
Screw, M5 with upturned lugs
Screw, M4 with upturned lugs
9 ACTUATOR COLOR & LEGEND 5
Actuator Color
I-O
ON-OFF
Dual
Legend Color
White
A
B1
Black
Black
C
D2
White
Red
F
G3White
Green
H
J4White
Blue
K
L5White
Yellow
M
N6Black
Gray
P
Q7Black
Orange
R
S8Black
10 MOUNTING / BARRIERS
1
6-32 x 0.195 inches
A
6-32 X 0.195 inches (multi-pole units only)
2
ISO M3 x 5mm B
ISO M3 x 5mm (multi-pole units only)
BARRIERS
no
yes
no
yes
11 MAXIMUM APPLICATION RATING 6
A
65 VDC
C
120/240 VAC (Available only on 2 or 3-Pole units)
K
120 VAC
M
80 DC
12 AGENCY APPROVAL 7
A
Without Approvals
C
UL Recognized and CSA Accepted
T
UL 489A
Notes:
1 All standard catalog numbers are supplied with Vertical Legends. For Horizontal or other non-standard legends, choose “X” and order as a special catalog number.
2 For rating (T) 2 & 3 Pole not available.
3 Frequency and Time Delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not
available with approval T.
4 Voltage Coil Ratings starting with (J, K, or L) not available with approval T.
5 “OFF and/or “O” Legends are on Bracket and are only visible when the Paddle Actuator is in the off position.
6 Maximum Application Ratings (C & K) not available with approval T.
7 Not all approvals are available in all constructions. Consult factory for details.
CODEAMPERES
A06 6 DC
A12 12 DC
A18 18 DC
A24 24 DC
C C
11
Max. Appl.
Rating
J65 65 AC
K20 120 AC
L40 240 AC
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams | 21
Circuit & Terminal Diagrams: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
3 Schematic shown represents current trip circuit.
4 Circuits shown for >30 amps / VDE.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
22 | A-Series Circuit Breaker - Rocker - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line & load
terminal orientation on indicate OFF is opposite of indicate ON.
2 For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 All dimensions are in inches [millimeters].
4 Tolerance ± 0.20 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Rocker Snap-In Bracket - Dimensional Specifications | 23
Dimensional Specifications: in. [mm]
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line
& load terminal
2 For pole orientation with horizontal legend, rotate front view clockwise 90°.
Orientation on indicate “OFF” is opposite of indicate “ON”
3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54]
4 All dimensions are in Inches [millimeters].
5 Tolerance ±.020 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
24 | A-Series Circuit Breaker - Flat Rocker - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 Tolerance ± 0.20 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
A-Series Circuit Breaker - Recessed Paddle - Dimensional Specifications | 25
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ± 0.20 [.51] unless otherwise specified
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
26 | A-Series Circuit Breaker - PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1 Drawing illustrates A-Series with VDE certification.
2 All dimensions are in inches [millimeters].
3 Tolerance ± 0.20 [.51] unless otherwise specified
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Reps & Contact | 27
Authorized Sales Representatives
Click on the group name on the map below to find your local representative or visit
www.carlingtech.com/findarep.
«
«
Matera
W. Canada
Matera
E. Canada
MIDWEST
DM
Michigan
TEMCO Northwest
Alaska, Hawaii
«
NORTHERN
Hanna Lind Ltd.
Melody
Emery
Sierra
Bridge Marketing
Omega Limited
Dy-tronix Inc.
LD. Allen
Norris
DM Assoc
East
Pacent
DM
Assoc
TSI North
TSI
WEST
Signal
Enterprises
Luscombe
Engineering
Pinnacle Marketing
Matrix
DM Mexico
South America
Mexico
«
«
Sunbelt Components
SOUTHEAST
ProRep
Solutions
LATIN AMERICA
Americas
Europe
Middle East
Africa
Asia-Pacific
Oceania
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: [email protected]
Northern Region Sales Office: [email protected]
Southeast Region Sales Office: [email protected]
Midwest Region Sales Office: [email protected]
West Region Sales Office: [email protected]
Latin America Sales Office: [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China: [email protected]
Shanghai, China: [email protected]
Pune, India: [email protected]
Kaohsiung, Taiwan: [email protected]
Yokohama, Japan: [email protected]
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: [email protected]
Germany: [email protected]
France: [email protected]
www.carlingtech.com
REV_03_2016