A-Series A-Series CIRCUIT BREAKER Well known for their proven reliability, Carling Technologies’ A-Series hydraulic magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. When front panel operation and aesthetics demand a clean, contemporary design, the visi-rocker or paddle actuators are ideally suitable. A sealed toggle actuator style is also available and ideal for harsh environment applications requiring additional sealing protection. Optional rocker-guard and pushto-reset bezels, which help prevent inadvertent actuation, are also available. 1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL Recognized, UL Listed, UL1500, UL1077, TUV, VDE & CSA Product Highlights: Up to 50 amps in a compact size Various actuator styles Sealed metal toggle option tested to MIL-PRF-55629C. Meets IP68 Requirements Typical Applications: Telecom/Datacom Marine Military Renewable Energy Generators & Welder Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | A-Series Circuit Breaker - General Specifications Electrical Maximum Voltage Current Ratings Standard Voltage Coils Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance 277VAC 50/60 Hz, 80VDC Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Minimum: 100 Megohms at 500 VDC UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 15 25 20.1 - 50.0 35 Pulse Tolerance Curves Mechanical Endurance Trip Free Trip Indication Physical Number of Poles Internal Circuit Config. Weight Standard Colors 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Housing - Black; Actuator- See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. A-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS Voltage Circuit Configuration Series Max Rating Current Rating Load Frequency Phase Full Amps 32 65 DC DC ----- 80 DC --- 125 125 125 125 / 250 125 / 250 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 1 1 14 13 13 1 250 50 / 60 14 3 Dual Coil 277 32 65 50 / 60 DC DC 1 ----- 80 DC --- 125 50 / 60 1 125 125 / 250 125 / 250 50 / 60 50 / 60 50 / 60 14 13 13 1 1 1 14 250 50 / 60 3 Shunt Relay Switch Only 277 80 125 / 250 50 / 60 DC 50 / 60 250 50 / 60 277 80 125 / 250 50 / 60 DC 50 / 60 250 50 / 60 277 65 80 50 / 60 DC DC 250 50 / 60 277 50 / 60 1 --1 1 3 1 --13 1 3 1 ----1 3 1 0.02 - 15 31 - 50 0.02 - 30 --0.02 - 30 1 - 50 1 - 50 0.02 - 30 0.02 - 50 0.02 - 30 0.02 - 30 --1 - 50 0.02 - 30 31 - 50 0.02 - 30 0.02 - 50 0.02 - 50 0.02 - 30 --0.02 - 30 1 - 50 0.02 - 30 0.02 - 30 0.02 - 50 0.02 - 30 0.02 - 30 --1 - 50 0.02 - 30 31 - 50 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 30 0.02 - 50 0.02 - 30 --0.02 - 50 0.02 - 30 General Purpose Amps ------31 - 50 ----------------------------31 - 50 --------------31 - 50 --------------------------------31 - 50 --31 - 50 Short Circuit Capacity (Amps) UL / CSA With Backup Without Fuse Backup Fuse --5000 --7500 --7500 --7500 --3000 --2000 --1000 --3000 --3000 --1500 --3000 --3000 --1000 5000 2 --2000 1 --5000 1 ----5000 --7500 --7500 --7500 --3000 --2000 --1000 --3000 --3000 --1500 --3000 --3000 --1000 5000 2 --2000 1 --5000 1 ----7500 --3000 --3000 5000 2 --5000 1 ----7500 --3000 --3000 5000 2 --5000 1 --- Application Codes UL CSA TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC1, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U2 TC1, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC3, OL1, U3 TC1, 2, OL1, U2 TC1, 2, OL1, U2 TC1, 2, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC3, OL1, U3 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, OL1, U2 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL0, U1 TC1, OL1, U2 TC1, OL1, U2 TC3, OL1, U3 TC1, 2, OL1, U1 TC1, 2, OL1, U2 TC1, OL0, U2 TC1, OL1, U2 TC1, 2, OL0, U1 TC3, OL1, U3 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 TC1, 2, OL1, C1 TC1, 2, OL1, C1 not applicable Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Construction Notes Rocker Version Rocker Version Handle Single Pole Break Two Pole Break Rocker Version Rocker Version Single Pole Break Two Pole Break 4 | A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. 1 3 2 3 2 3 2 Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - General Specifications | 5 Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. A-SERIES TABLE C: UL1500 (Marine Ignition Protected) VOLTAGE CIRCUIT CONFIGURATION CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES MAX. RATING FREQUENCY PHASE FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 32 1 65 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 125 50 / 60 1 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 125 / 250 50 / 60 12 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 250 50 / 60 1 0.02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 SERIES Notes: Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system 1 Available with Special Catalog Number Only (consult factory) 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Parallel Pole Construction Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) TUV Certified EN60934, under License No. R72103448 UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 6 | A-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme A A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 10 450 6 Frequency & Delay 7 Current Rating 1 SERIES A C 10 Mounting/ Barriers 11 Agency Approval 7 CURRENT RATING (AMPERES) CODEAMPERES 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 One 2 Two 1 B 1 8 9 Terminal Actuator Color 3 4 Three Four 5 6 Five Six 4 CIRCUIT A 2 Switch Only (No Coil) F 3 B Series Trip (Current) G 3 C Series Trip (Voltage) H 3,4 D 3 Shunt Trip (Current) 3 E Shunt Trip (Voltage) K 3,4 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 31 DC, 50/60Hz Ultra Short 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 42 7 50/60Hz Short, Hi-Inrush 44 7 50/60Hz Medium, Hi-Inrush 46 7 50/60Hz Long, Hi-Inrush 52 7 DC, Short,Hi-Inrush 54 7 DC, Medium, Hi-Inrush 56 7 DC, Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.. 10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A. 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 14 Terminal Code Q not available with VDE certification. 15 Single pole only. 0200.020 2250.250 4202.000 0250.025 2300.300 5222.250 0300.030 2350.350 5272.750 0350.035 2400.400 4303.000 0400.040 2450.450 4353.500 0450.045 2500.500 4404.000 0500.050 2550.550 4454.500 0550.055 2600.600 4505.000 0600.060 2650.650 4555.500 0650.065 2700.700 4606.000 0700.070 2750.750 4656.500 0750.075 2800.800 4707.000 0800.080 2850.850 4757.500 0850.085 2900.900 4808.000 0900.090 2950.950 4858.500 0950.095 4101.000 4909.000 2100.100 5121.250 4959.500 2150.150 4151.500 610 10.000 2200.200 517 1.750 71010.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 835.000 640 840.000 645 845.000 650 850.000 CODEAMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) E 11 Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 11 3 Screw 8-32 (Bus Type) & 30° bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend 11 11 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 6 Screw 8-32 with upturned lugs L 12 0.250 Q.C./ Solder Lug & 30° bend M 11 M6 Threaded Stud 7 Screw 8-32 (Bus Type) Q 14Push-In Stud & 30° bend R Screw M4 with upturned lugs 8 Screw 10-32 with upturned lugs & 30° bend & 30° bend T 11 Screw M4 (Bus Type) 9 Screw 10-32 (Bus Type) & 30° bend & 30° bend P 13 Printed Circuit Board Terminals B Screw M5 with upturned lugs S 13 Push-On 0.110 Tab (Q.C.) C Screw M4 with upturned lugs 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS Black (short handle)15 TU Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 9White 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75” wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides BARRIERS no yes no yes no yes no yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Handle UL489A – Ordering Scheme | 7 A A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 450 6 Frequency & Delay 7 Current Rating 2 ACTUATOR 1 A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 2 Two 3 Three 4 Four 4 CIRCUIT B Series Trip (Current) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 3 DC, Short,Hi-Inrush 54 3 DC, Medium, Hi-Inrush 56 3 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODEAMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 8 Terminal 9 Actuator Color 10 Mounting/ Barriers M T 11 Max. Appl. Rating 12 Agency Approval 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF Dual Legend Color White B1 Black Black D2 White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black Black (short handle) 10 U9White 1 SERIES A 5 AUXILIARY/ALARM SWITCH 2 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 1 B 1 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 335.000 640 340.000 645 345.000 650 350.000 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 Screw 10-32 (Bus Type) 2 Screw 8-32 with upturned lugs & 30° bend 3 7 Screw 8-32 (Bus Type) B Screw M5 with upturned lugs 4 Screw 10-32 with upturned lugs F Screw M5 with upturned lugs 5 7 Screw 10-32 (Bus Type) & 30° bend 6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend & 30° bend H Screw M5 (Bus Type) 7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud & 30° bend P 8 Printed Circuit Board Terminals 8 Screw 10-32 with upturned lugs Q 9 Push-In Stud & 30° bend 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75” wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides BARRIERS no yes no yes no yes no yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 8 | A-Series Circuit Breaker - Handle WORLD – Ordering Scheme A A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 450 6 Frequency & Delay 7 Current Rating 1 SERIES A 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 One 2 Two 3 4 Three Four 5 6 4 CIRCUIT A 2 Switch Only (No Coil) D 3 B Series Trip (Current) E 3 C Series Trip (Voltage) H 3,4 Five Six Shunt Trip (Current) Shunt Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 31 DC, 50/60Hz Ultra Short 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 42 7 50/60Hz Short, Hi-Inrush 44 7 50/60Hz Medium, Hi-Inrush 46 7 50/60Hz Long, Hi-Inrush 52 7 DC, Short,Hi-Inrush 54 7 DC, Medium, Hi-Inrush 56 7 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) 1 A 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers P 11 Agency Approval 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) B Screw M5 with upturned lugs 2 Screw 8-32 with upturned lugs C Screw M4 with upturned lugs 3 11 Screw 8-32 (Bus Type) E 11 Screw M4 (Bus Type) 4 Screw 10-32 with upturned lugs F Screw M5 with upturned lugs 5 11 Screw 10-32 (Bus Type) & 30° bend 6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend 11 & 30° bend H Screw M5 (Bus Type) 7 Screw 8-32 (Bus Type) R Screw M4 with upturned lugs & 30° bend & 30° bend 8 Screw 10-32 with upturned lugs T 11 Screw M4 (Bus Type) & 30° bend & 30° bend 9 Screw 10-32 (Bus Type) & 30° bend 9 ACTUATOR COLOR & LEGEND Actuator Color I-O Dual Legend Color White A1 Black Black C2 White Red F3White Green H4White Blue K5White Yellow M6Black Gray P7Black Orange R8Black 15 Black (short handle) T9White 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm (multipole only) Front panel Snap-In, 0.75” wide bezel 5 without Handleguard 6 without Handleguard (multipole only) Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; (multipole only) .105” bezel overhang on all sides BARRIERS no yes no yes no yes no yes CODEAMPERES 2100.100 2850.850 4555.500 2150.150 2900.900 4606.000 2200.200 2950.950 4656.500 2250.250 4101.000 4707.000 2300.300 5121.250 4757.500 2350.350 4151.500 4808.000 2400.400 517 1.750 4858.500 2450.450 4202.000 4909.000 2500.500 5222.250 4959.500 2550.550 5272.750 610 10.000 2600.600 4303.000 71010.500 2650.650 4353.500 611 11.000 2700.700 4404.000 71111.500 2750.750 4454.500 61212.000 2800.800 4505.000 71212.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 835.000 640 840.000 645 845.000 650 850.000 CODEAMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC 11 AGENCY APPROVAL P TUV Certified, UL Recognized & CSA Accepted Q UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H. 10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. 12 Single pole only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Rocker UL489A – Ordering Scheme | 9 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend 450 7 Current Rating 1 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers M T 11 Max. Appl. Rating 12 Agency Approval 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 Screw 10-32 (Bus Type) 2 Screw 8-32 with upturned lugs & 30° bend 7 3 Screw 8-32 (Bus Type) B Screw M5 with upturned lugs 4 Screw 10-32 with upturned lugs F Screw M5 with upturned lugs 5 7 Screw 10-32 (Bus Type) & 30° bend 6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend & 30° bend H Screw M5 (Bus Type) 7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud & 30° bend P 8 Printed Circuit Board Terminals 8 Screw 10-32 with upturned lugs Q 9 Push-In Stud & 30° bend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 10 ON-OFFDual 10 Single Color Visi-Rocker White B1Black White Black D2Whiten/a Red G3WhiteRed Green J4WhiteGreen Blue L5WhiteBlue Yellow N6Black Yellow Gray Q7Black Gray Orange S8Black Orange 3 POLES 2 1 One 2 Two 3 Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 2 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 DC, Short,Hi-Inrush 54 DC, Medium, Hi-Inrush 56 DC, Long, Hi-Inrush CODEAMPERES 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified 7 CURRENT RATING (AMPERES) 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 10 MOUNTING / BARRIERS 11 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 435.000 640 440.000 645 445.000 650 450.000 Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 10 | A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 11 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 12 | A-Series Circuit Breaker - Handle - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 5 - Dimensional Specifications | 13 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 14 | A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 7 - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme | 15 A M 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 5 Aux/Alarm Switch 10 450 6 Frequency & Delay 7 Current Rating 1 SERIES A 2 ACTUATOR 1 M Sealed Toggle, one per unit 3 POLES 1 One 2 Two 3 Three 4 CIRCUIT A 2 Switch Only (No Coil) F 3 B Series Trip (Current) G 3 C Series Trip (Voltage) H 3,4 D 3 Shunt Trip (Current) E 3 Shunt Trip (Voltage) K 3,4 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 31 DC, 50/60Hz Ultra Short 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 42 7 50/60Hz Short, Hi-Inrush 44 7 50/60Hz Medium, Hi-Inrush 46 7 50/60Hz Long, Hi-Inrush 52 7 DC, Short,Hi-Inrush 54 7 DC, Medium, Hi-Inrush 56 7 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODEAMPERES 0200.020 0250.025 0300.030 0350.035 0400.040 0450.045 0500.050 0550.055 0600.060 0650.065 0700.070 0750.075 0800.080 0850.085 0900.090 0950.095 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 425 2.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 835.000 640 840.000 645 845.000 650 850.000 1 0 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 9 1 10 Push-On 0.250 Tab (Q.C.) E Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 3 Screw 8-32 (Bus Type) & 30° bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 6 Screw 8-32 with upturned lugs L 12 0.250 Q.C./ Solder Lug & 30° bend M M6 Threaded Stud 7 Screw 8-32 (Bus Type) Q Push-In Stud & 30° bend R Screw M4 with upturned lugs 8 Screw 10-32 with upturned lugs & 30° bend & 30° bend T Screw M4 (Bus Type) 9 Screw 10-32 (Bus Type) & 30° bend & 30° bend P 12 Printed Circuit Board Terminals B Screw M5 with upturned lugs S Push-On 0.110 Tab (Q.C.) C Screw M4 with upturned lugs 9 LEGEND PLATE 0 No legend plate 10 MOUNTING / BARRIERS MOUNTING STYLEBARRIERS 1 Standard Hex Nut no A Standard Hex Nut (multipole only) yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Actuator Code M: Handle location as viewed from front of panel: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 UL Recognition and CSA Certification available on one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q. 10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Code L : available up to 30A. 12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C. OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 CODEAMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC C 11 Agency Approval J65 65 AC K20 120 AC L40 240 AC Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 16 | A-Series Circuit Breaker - Sealed Toggle - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 17 A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 24 630 6 Frequency & Delay 7 Current Rating 2 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers D 11 Agency Approval 7 CURRENT RATING (AMPERES) 1 SERIES A CODEAMPERES 0200.020 2250.250 4202.000 0250.025 2300.300 5222.250 0300.030 2350.350 5272.750 0350.035 2400.400 4303.000 0400.040 2450.450 4353.500 0450.045 2500.500 4404.000 0500.050 2550.550 4454.500 0550.055 2600.600 4505.000 0600.060 2650.650 4555.500 0650.065 2700.700 4606.000 0700.070 2750.750 4656.500 0750.075 2800.800 4707.000 0800.080 2850.850 4757.500 0850.085 2900.900 4808.000 0900.090 2950.950 4858.500 0950.095 4101.000 4909.000 2100.100 5121.250 4959.500 2150.150 4151.500 610 10.000 2200.200 517 1.750 71010.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset , Single color R Vertical legend U Horizontal legend V No legend 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 835.000 640 840.000 645 845.000 650 850.000 CODEAMPERES 3 POLES 1 One 2 Two 3 Three 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 6,7 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 31 DC, 50/60Hz Ultra Short 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 42 9 50/60Hz Short, Hi-Inrush 44 9 50/60Hz Medium, Hi-Inrush 46 9 50/60Hz Long, Hi-Inrush 52 9 DC, Short,Hi-Inrush 54 9 DC, Medium, Hi-Inrush 56 9 DC, Long, Hi-Inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA Accepted available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B & C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C. 16 Terminal Code Q not available with VDE. 17 Terminal Code S used on voltage coil circuit constructions only. 18 Color shown is visi and legend with remainder of rocker black. 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L. A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC 8 TERMINAL 11 1 12 Push-On 0.250 Tab (Q.C.) E 13 Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 13 3 Screw 8-32 (Bus Type) & 30° bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend H 13 Screw M5 (Bus Type) 5 13 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug & 30° bend M 13M6 Threaded Stud 7 Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals & 30° bend Q 16Push-In Stud 8 Screw 10-32 with upturned lugs R Screw M4 with upturned lugs & 30° bend & 30° bend 9 Screw 10-32 (Bus Type) S 17 Push-On 0.110 Tab (Q.C.) & 30° bend & 30° bend B Screw M5 with upturned lugs T Screw M4 (Bus Type) C Screw M4 with upturned lugs & 30° bend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 12 ON-OFFDual 12 Single Color Visi-Rocker White B1Black White Black D2Whiten/a Red G3WhiteRed Green J4WhiteGreen Blue L5WhiteBlue Yellow N6Black Yellow Gray Q7Black Gray Orange S8Black Orange 10 MOUNTING / BARRIERS 20 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 18 | A-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 24 630 6 Frequency & Delay 7 Current Rating 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2 Two 3 Three 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 6,7 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 6 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 31 DC, 50/60Hz Ultra Short 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long 42 9 50/60Hz Short, Hi-Inrush 44 9 50/60Hz Medium, Hi-Inrush 46 9 50/60Hz Long, Hi-Inrush 52 9 DC, Short,Hi-Inrush 54 9 DC, Medium, Hi-Inrush 56 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODEAMPERES 0200.020 2250.250 4202.000 0250.025 2300.300 5222.250 0300.030 2350.350 5272.750 0350.035 2400.400 4303.000 0400.040 2450.450 4353.500 0450.045 2500.500 4404.000 0500.050 2550.550 4454.500 0550.055 2600.600 4505.000 0600.060 2650.650 4555.500 0650.065 2700.700 4606.000 0700.070 2750.750 4656.500 0750.075 2800.800 4707.000 0800.080 2850.850 4757.500 0850.085 2900.900 4808.000 0900.090 2950.950 4858.500 0950.095 4101.000 4909.000 2100.100 5121.250 4959.500 2150.150 4151.500 610 10.000 2200.200 517 1.750 71010.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 835.000 640 840.000 645 845.000 650 850.000 CODEAMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC 9 Actuator Color 10 Mounting/ Barriers E 11 Agency Approval 8 TERMINAL 11 1 12 Push-On 0.250 Tab (Q.C.) E 13 Screw M4 (Bus Type) 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 3 13 Screw 8-32 (Bus Type) & 30° bend 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend 13 13 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 5 6 Screw 8-32 with upturned lugs L 14 0.250 Q.C./ Solder Lug & 30° bend M 13M6 Threaded Stud 7 Screw 8-32 (Bus Type) P 15 Printed Circuit Board Terminals & 30° bend Q Push-In Stud 8 Screw 10-32 with upturned lugs R Screw M4 with upturned lugs & 30° bend & 30° bend 9 Screw 10-32 (Bus Type) S 16 Push-On 0.110 Tab (Q.C.) & 30° bend & 30° bend B Screw M5 with upturned lugs T Screw M4 (Bus Type) C Screw M4 with upturned lugs & 30° bend 1 SERIES A 3 POLES 2 1 One 2 3 1 8 Terminal J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC J65 65 AC K20 120 AC L40 240 AC 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 17 ON-OFFDual 17 Single Color Visi-Rocker White B1Black White Black D2Whiten/a Red G3WhiteRed Green J4WhiteGreen Blue L5WhiteBlue Yellow N6Black Yellow Gray Q7Black Gray Orange S8Black Orange 10 MOUNTING / BARRIERS 18 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes 19 RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes 6 ISO M3 x 5mm no F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Flat Rocker UL 489A – Ordering Scheme | 19 A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 630 6 Frequency & Delay 7 Current Rating 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2 Two 3 Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 3 7 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 8 2 S.P.D.T., 0.110 Q.C. Term. 9 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 DC, Short,Hi-Inrush 54 DC, Medium, Hi-Inrush 56 DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODEAMPERES 0200.020 0250.025 0300.030 0350.035 0400.040 0450.045 0500.050 0550.055 0600.060 0650.065 0700.070 0750.075 0800.080 0850.085 0900.090 0950.095 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 9 Actuator Color 10 Mounting/ Barriers M T 11 Max. Appl. Rating 12 Agency Approval 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) 9 Screw 10-32 (Bus Type) 2 Screw 8-32 with upturned lugs & 30° bend 3 7 Screw 8-32 (Bus Type) B Screw M5 with upturned lugs 4 Screw 10-32 with upturned lugs F Screw M5 with upturned lugs 5 7 Screw 10-32 (Bus Type) & 30° bend 6 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend & 30° bend H Screw M5 (Bus Type) 7 Screw 8-32 (Bus Type) M 7 M6 Threaded Stud & 30° bend P 8 Printed Circuit Board Terminals 8 Screw 10-32 with upturned lugs Q 9 Push-In Stud & 30° bend 1 SERIES A 3 POLES 2 1 One 2 3 1 8 Terminal 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 435.000 640 440.000 645 445.000 650 450.000 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 11 ON-OFFDual 11 Single Color Visi-Rocker White B1Black White Black D2Whiten/a Red G3WhiteRed Green J4WhiteGreen Blue L5WhiteBlue Yellow N6Black Yellow Gray Q7Black Gray Orange S8Black Orange 10 MOUNTING / BARRIERS 12 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes 6 ISO M3 x 5mm no F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no D ISO M3 x 5mm (multi-pole units only) yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed J UL489A Listed, TUV Certified Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. 12 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 20 | A-Series Circuit Breaker - Recessed Paddle – Ordering Scheme A Y 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Auxiliary Switch 24 620 6 Frequency & Delay 7 Current Rating 1 SERIES A 2 ACTUATOR 1 Y Single Color Recessed Paddle Actuator with Vertical Legends 3 POLES 2 1 One 2 4 CIRCUIT A Switch-Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D Shunt Trip (Current) E Shunt Trip (Voltage) Two F G H K 3 Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Shunt Trip Current Coil 5 AUXILIARY SWITCH 0 without Aux Switch 1 S.P.D.T. with 0.093 Q.C. Terminals 2 S.P.D.T. with 0.110 Q.C. Terminals 3 S.P.D.T. with 0.139 Solder Lug Terminals 4 S.P.D.T. with 0.110 Q.C. Terminals (Gold Contacts) 5 S.P.D.T. with 0.093 Q.C. Terminals (Gold Contacts) 6 S.P.S.T.-N.O. with 0.139 Solder Lug Terminals 7 S.P.S.T.-N.O. with 0.110 Q.C. Terminals (Gold Contacts) 8 S.P.S.T.-N.O. with 0.187 Q.C. Terminals 9 S.P.D.T. with 0.187 Q.C. Terminals 6 FREQUENCY & DELAY 3 3 DC, 50/60 Hz Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 50/60 Hz Instantaneous 21 50/60 Hz Ultra Short 22 24 26 42 44 46 52 54 56 50/60 Hz Short 50/60 Hz Medium 50/60 Hz Long 50/60 Hz Short Hi-Inrush 50/60 Hz Medium Hi-Inrush 50/60 Hz Long Hi-Inrush DC, Short, Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) 4 CODEAMPERES 2200.200 2950.950 4606.000 2250.250 4101.000 4656.500 2300.300 5121.250 4707.000 2350.350 4151.500 4757.500 2400.400 517 1.750 4808.000 2450.450 4202.000 4858.500 2500.500 5222.250 4909.000 2550.550 4252.500 4959.500 2600.600 5272.750 610 10.000 2650.650 4303.000 71010.500 2700.700 4353.500 611 11.000 2750.750 4404.000 71111.500 2800.800 4454.500 61212.000 2850.850 4505.000 71212.500 2900.900 4555.500 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 645 45.000 65050.000 4 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 1 Push-On 0.250 Tab (Q.C.) C 2 Screw 8-32 with upturned lugs E 3 Screw 8-32 (Bus Type) F 4 Screw 10-32 with upturned lugs 5 Screw 10-32 (Bus Type) G 6 Screw 8-32 with upturned lugs H & 30° bend L 7 Screw 8-32 (Bus Type) M & 30° bend P 8 Screw 10-32 with upturned lugs Q & 30° bend R 9 Screw 10-32 (Bus Type) & 30° bend S B Screw M5 with upturned lugs T A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 12 Agency Approval Screw, M4 with upturned lugs Screw, M4 (Bus Type) Screw M5 with upturned lugs & 30° bend Screw M5 (Bus Type) & 30° bend Screw M5 (Bus Type) 0.250 Q.C./Solder Lug M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud Screw, M4 with upturned lugs & 30° Bend Screw, M5 with upturned lugs Screw, M4 with upturned lugs 9 ACTUATOR COLOR & LEGEND 5 Actuator Color I-O ON-OFF Dual Legend Color White A B1 Black Black C D2 White Red F G3White Green H J4White Blue K L5White Yellow M N6Black Gray P Q7Black Orange R S8Black 10 MOUNTING / BARRIERS 1 6-32 x 0.195 inches A 6-32 X 0.195 inches (multi-pole units only) 2 ISO M3 x 5mm B ISO M3 x 5mm (multi-pole units only) BARRIERS no yes no yes 11 MAXIMUM APPLICATION RATING 6 A 65 VDC C 120/240 VAC (Available only on 2 or 3-Pole units) K 120 VAC M 80 DC 12 AGENCY APPROVAL 7 A Without Approvals C UL Recognized and CSA Accepted T UL 489A Notes: 1 All standard catalog numbers are supplied with Vertical Legends. For Horizontal or other non-standard legends, choose “X” and order as a special catalog number. 2 For rating (T) 2 & 3 Pole not available. 3 Frequency and Time Delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not available with approval T. 4 Voltage Coil Ratings starting with (J, K, or L) not available with approval T. 5 “OFF and/or “O” Legends are on Bracket and are only visible when the Paddle Actuator is in the off position. 6 Maximum Application Ratings (C & K) not available with approval T. 7 Not all approvals are available in all constructions. Consult factory for details. CODEAMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC C C 11 Max. Appl. Rating J65 65 AC K20 120 AC L40 240 AC Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams | 21 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 22 | A-Series Circuit Breaker - Rocker - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Rocker Snap-In Bracket - Dimensional Specifications | 23 Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate “OFF” is opposite of indicate “ON” 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 24 | A-Series Circuit Breaker - Flat Rocker - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com A-Series Circuit Breaker - Recessed Paddle - Dimensional Specifications | 25 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 26 | A-Series Circuit Breaker - PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance ± 0.20 [.51] unless otherwise specified Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Reps & Contact | 27 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_03_2016