0RODUCT$ATA3HEET !-0 -/$5,!237)4#(%$-/$%2%#4)&)%2 2- &%!452%3 s 37)4#(%$-/$% s 0&# s %&&)#)%.#9 s !54/-!4)#,/!$3(!2).' s (/437!0#!0!",% s #/-0!#43):% s 3(%,&-/5.4%$ s 4%,%#/-"5,+0/7%22!4%$ s "%,,#/2%"!3%$$%3)'. $%3#2)04)/. 4HE2--ODULAR3WITCH-ODE2ECTIFIERISRQH RIDFAMILYOFRECTIFIERSTHATMAYBEUSEDINMODULAR POWERPLANTS4HISHIGHPOWERUNITWILLFUNCTION INPARALLELWITHANYRECTIFIERWITHSIMILARCURRENTSHARING CAPACITIES4HISVERSATILEANDEFFICIENTRECTIFIERISIDEAL FORUSEINADVANCEDTELECOMMUNICATIONSAPPLICATIONS)TS SMALLSIZEALLOWSTHEUSERTOPLANECONOMICALLYFORSYSTEM EXPANSIONATMINIMUMCOSTANDMAKESITIDEALFORUSEIN ST AND MAKES K IT ID IDEALL FFOR USE IIN N FIBEROPTICMICROWAVEANDOTHERAPPLICATIONSWHERESPACE OTHER AP O PPLICATIONS WHERE SPACE E ISATAPREMIUM s 3/&434!24452./. s ).&).)4%&5,,#522%.43(/24#)2#5)4 #!0!",% s "5),4).!#$#$)3#/..%#43 s ).4%,,)'%.4()'(6/,4!'%3%.3% 02/4%#4)/. s "!44%29/2"!44%29,%33/0%2!4)/. s '5!2!.4%%$./3).',%0!24&!),52%#!. ,%!$4//54054()'(6/,4!'% s '5!2!.4%%$3!&%/0%2!4)/.4/6!# s &2/.40!.%,-%4%2 s 4($ !'%.#9!002/6!,3 Contact Factory for Replacement Model www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Input Specifications Parameter Operating Range Conditions Min 45 - 65 Hz, single phase, no taps required 183 Current Efficiency Power Factor Correction (PFC) Adjustable Typ Max Units 264 VAC 27 >85 >.99 A % MEASUREMENTS OF RM24150 Module Shelf* Weight Height 25 lbs. 7U (12.25”) Depth Width 15.25” 5.1” Weight Height Depth Width 18 lbs. 7U (12.25”) 15..25” maximum 23” rack mount *These measurements are specifically for the 600A Power Shelf for up to 4 quantity RM24150. Please consult factory for other shelf and power plant options. GENERAL FEATURES Hot Swappable Modules These shelf-mounted modules are easy and safe to install or remove while system is operational without affecting the overall system’s performance. Current Limit The Current Limit is adjustable between 0A to 150A. Upon exceeding this limit, the rectifier automatically reduces output voltage. Parallel Operation and Automatic Load Sharing Forced or passive load sharing is available between modules of the same operating voltages in parallel applications. Safety UL/CUL Recognized: UL 1950/CSA 950 File Number: E181908. Alarm Outputs Rectifier Fail Alarm Thermal Shutdown Occurring Open Sense Lead Has Occurred AC Power Has Failed Alarm DC Breaker Is Open Alarm AC Breaker Is Open Alarm Control Inputs (RFA) (THSD) (OS) (ACF) (DCBKR) (ACBKR) High Voltage Shutdown Restart Equalize Temporary Restraint (HVSD) (RS) (EQ) (TR) } All control inputs are initiated with a ground closure Emergency Shutdown (EMSD) } 24VAC voltage reference to ground Note: All alarms are “Form A” relay type contacts www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000 Output Specifications Parameter Conditions Min Typ Max Units Voltage Adjustment Range Regulation Load Current Hold-Up Time Filtering Voice band Wide band noise float voltage 24 28 VDC equalize voltage 24 30 VDC 0-100% load within specified input voltage and frequency range within a 10 - 100% rating >16 mS @ 20MHz < 32 <350 dBrnc mV p-p Storage non-condensing -0 +32 +50 122 °C °F -50 -58 0 0 +85 185 95 7000 °C °F % ft. 2133 m Btu/hr dBa 0 Heat Dissipation Audible Noise % % nominal AC line ENVIRONMENTAL Temperature Operating Humidity Altitude ± 0.5 ±10 @27V 5 ft. from any vertical surface 2440 <55 PROTECTION, ALARM AND CONTROL SYSTEMS Rectifier Failure Alarm (RFA) Problems occurring because of an unacceptable relationship between the output power and load conditions will cause a Rectifier Failure Alarm (RFA). This alarm consists of a red LED and a flashing green OK LED. Conditions which may lead to an RFA are: Low Current - Output current has decreased to below 5% of its rated value. Unit Shutdown - Any shutdown occurrence due to overvoltage, external shutdown command, unacceptable ambient temperature conditions or low AC input voltage. Fan Malfunction - The fan has stopped operating or is not providing the airflow needed to cool the unit. Over Temperature - The ambient temperature has exceeded 50°C. www.murata-ps.com High Voltage Shutdown (HVSD) The unit’s high voltage limit is adjustable up to 30VDC. When internal shutdown occurs, the unit may be restarted by a local switch or by a remote signal. Surge Protection The unit will withstand lightning and input surges of 6000V/3000A. Under Voltage Protection When input voltage is below 183 VAC, the rectifier’s operation is automatically inhibited. Technical enquiries - email: [email protected], tel: +1 508 339 3000 Mechanical All measurements are in inches Standard Options are shown, consult factory for other available options. www.murata-ps.com Technical enquiries - email: [email protected], tel: +1 508 339 3000