60W Single Output External Power
Test & Measurement/Industrial Series
Features

Meets DoE Efficiency Level VI Requirements
 No load input power
 Average Efficiency

Up to 60W of AC-DC Power

Universal Input 90-264Vac Input Range

IP22 Rated Enclosure

Meets “Heavy Industrial” Levels of EN61000
EMC Requirements

Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin

Approved to EN/IEC/UL60950-1, 2nd Edition,
Am. 2

E-cap life of >8 years

>900,000 hours MTBF

3 Year Warranty

IP22 Rated Enclosure
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial
levels of various EN61000-4-x standards for EMC. The TE60A series models also meet Class B conducted and radiated
EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment
and other industrial applications.
Model Selection
Model
Number
TE60A0551F01
TE60A0903F01
TE60A1203F01
TE60A1503F01
TE60A1803F01
TE60A2403F01
TE60A4803F01
TE60A0551N01
TE60A0903N01
TE60A1203N01
TE60A1503N01
TE60A1803N01
TE60A2403N01
TE60A4803N01
TE60A0551Q01
TE60A0903Q01
TE60A1203Q01
TE60A1503Q01
TE60A1803Q01
TE60A2403Q01
TE60A4803Q01
Notes:
Volts
5.0V
9.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
9.0V
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
9.0V
12.0V
15.0V
18.0V
24.0V
48.0V
Output
Current
7.00A
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
7.00A
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
7.00A
6.00A
5.00A
4.00A
3.40A
2.70A
1.35A
Output
Power
35W
54W
60W
60W
60W
60W
60W
35W
54W
60W
60W
60W
60W
60W
60W
54W
60W
60W
60W
60W
60W
Ripple &
Noise¹
75mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
90mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
Line
Regulation
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Output Cable
& Connector
6 pin Molex Type2
Input
Configuration
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
Class I Desktop,
IEC60320 C14
Receptacle
6 pin Molex Type2
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
Class II Desktop,
IEC60320 C8
Receptacle
6 pin Molex Type2
1150mm long, UL2464,
18AWG, 4 conductors;
2.5 x 5.5 x 9.5mm Straight
Barrel Type, center positive
Class II Desktop,
IEC60320 C18
Receptacle
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. For 5V and 6V models, values listed
are typical, 100mV pk-pk maximum.
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01).
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE60 Rev 2.7
25-APR-16
1
TE60
60W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 1 sec @115Vac, full load
115Vac: 1.5A, 230Vac: 0.75A
Hold-up Time
20mS min., at full Load, 100Vac input
F1, F2: 2A, 250Vac fuses (line & neutral lines)
provided on all models
No Load Input
Power
<0.210W per DoE Efficiency Level VI
Requirements
Transient
Response
E-Cap Life
Weight
Safety Drop Test
Dimensions
Vibration
Short Circuit
Protection
Overvoltage
Protection
Meets US DoE Efficiency Level VI average
efficiency levels
60W continuous – See models chart for
specific voltage model ratings.
Output Voltage
Overload Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Output Power
Ripple and Noise
Overtemperature
Protection
264Vac, cold start: will not exceed 40A
Isolation
See models chart on pg 1.
500µs response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day. (80% load on 12V model)
W: 2.67” x L: 4.25” x H: 1.29”
W: 67.9mm x L: 108mm x H: 32.7mm
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
-20°C to +70°C. Derate above 40°C.
Start Up at -40°C, full load, (warmup period before
MTBF
Altitude
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
130 to 150% of output voltage (max. 60V on
48V model), hiccup mode
Operating
Temperature
Temperature
Derating
1.4m from table top to wooden platform, 6
faces.
Hiccup Mode, auto recovery.
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Storage Temperature
400g
130 to 180% of rating, Hiccup Mode
Safety Standards
Case Temperature
See models chart on pg 1.
Will shutdown upon an over-temperature
condition, auto-recovery.
Shock
all parameters are within published specifications).
Case Temperatures are within regulatory
guidelines. Care should be taken to avoid
prolonged contact with skin or other heat
sensitive surfaces.
See derating curve below.
>250,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
-40°C to +85°C
Operating: to 5000m
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE60 Rev 2.7
25-APR-16
2
TE60
60W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions:
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions:
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise:
High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55024/IEC61000-4-5, Level 4, +/-1kV DM, +/-4kV CM, Criteria A
EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz
and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
MTE60 Series Output Power Derating Curve:
TE60 Family Derating curve
Output Power- Watts
70
60
50
40
12V
30
18V
20
24V
10
48V
0
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperature- ͦC
www.slpower.com
TE60 Rev 2.7
25-APR-16
3
TE60
60W Single Output External Power
Test & Measurement/Industrial Series
Mechanical Drawing:
Notes: 1) All dimensions in (mm).
2) 2.5mm barrel connector shown, other options
are available.
3) The unit should not be covered or enclosed to
protect against excessive case temperature rise.
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
www.slpower.com
TE60 Rev 2.7
25-APR-16
4
TE60
60W Single Output External Power
Test & Measurement/Industrial Series
Efficiency Level VI Information:
TE60A 12V-48V
TE60A 5V
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE60 Rev 2.7
25-APR-16
5