TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets “Heavy Industrial” Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2nd Edition, Am. 2 E-cap life of >8 years >900,000 hours MTBF 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE60A series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Number TE60A0551F01 TE60A0903F01 TE60A1203F01 TE60A1503F01 TE60A1803F01 TE60A2403F01 TE60A4803F01 TE60A0551N01 TE60A0903N01 TE60A1203N01 TE60A1503N01 TE60A1803N01 TE60A2403N01 TE60A4803N01 TE60A0551Q01 TE60A0903Q01 TE60A1203Q01 TE60A1503Q01 TE60A1803Q01 TE60A2403Q01 TE60A4803Q01 Notes: Volts 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V Output Current 7.00A 6.00A 5.00A 4.00A 3.40A 2.70A 1.35A 7.00A 6.00A 5.00A 4.00A 3.40A 2.70A 1.35A 7.00A 6.00A 5.00A 4.00A 3.40A 2.70A 1.35A Output Power 35W 54W 60W 60W 60W 60W 60W 35W 54W 60W 60W 60W 60W 60W 60W 54W 60W 60W 60W 60W 60W Ripple & Noise¹ 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk Line Regulation ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% Load Regulation ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Output Cable & Connector 6 pin Molex Type2 Input Configuration 1150mm long, UL2464, 18AWG, 4 conductors; 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class I Desktop, IEC60320 C14 Receptacle 6 pin Molex Type2 1150mm long, UL2464, 18AWG, 4 conductors; 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C8 Receptacle 6 pin Molex Type2 1150mm long, UL2464, 18AWG, 4 conductors; 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C18 Receptacle 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01). 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE60 Rev 2.7 25-APR-16 1 TE60 60W Single Output External Power Test & Measurement/Industrial Series General Specifications AC Input Input Current Inrush Current Input Fuses Earth Leakage Current Efficiency 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 1 sec @115Vac, full load 115Vac: 1.5A, 230Vac: 0.75A Hold-up Time 20mS min., at full Load, 100Vac input F1, F2: 2A, 250Vac fuses (line & neutral lines) provided on all models No Load Input Power <0.210W per DoE Efficiency Level VI Requirements Transient Response E-Cap Life Weight Safety Drop Test Dimensions Vibration Short Circuit Protection Overvoltage Protection Meets US DoE Efficiency Level VI average efficiency levels 60W continuous – See models chart for specific voltage model ratings. Output Voltage Overload Protection Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Output Power Ripple and Noise Overtemperature Protection 264Vac, cold start: will not exceed 40A Isolation See models chart on pg 1. 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12V model) W: 2.67” x L: 4.25” x H: 1.29” W: 67.9mm x L: 108mm x H: 32.7mm Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac -20°C to +70°C. Derate above 40°C. Start Up at -40°C, full load, (warmup period before MTBF Altitude Relative Humidity Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Operating Temperature Temperature Derating 1.4m from table top to wooden platform, 6 faces. Hiccup Mode, auto recovery. EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Storage Temperature 400g 130 to 180% of rating, Hiccup Mode Safety Standards Case Temperature See models chart on pg 1. Will shutdown upon an over-temperature condition, auto-recovery. Shock all parameters are within published specifications). Case Temperatures are within regulatory guidelines. Care should be taken to avoid prolonged contact with skin or other heat sensitive surfaces. See derating curve below. >250,000 hours, full load, 110 & 220Vac input, 25°C amb., per Telcordia 332 Issue 6. -40°C to +85°C Operating: to 5000m Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE60 Rev 2.7 25-APR-16 2 TE60 60W Single Output External Power Test & Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields EN55024/IEC61000-4-5, Level 4, +/-1kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25°C ambient unless noted. MTE60 Series Output Power Derating Curve: TE60 Family Derating curve Output Power- Watts 70 60 50 40 12V 30 18V 20 24V 10 48V 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature- ͦC www.slpower.com TE60 Rev 2.7 25-APR-16 3 TE60 60W Single Output External Power Test & Measurement/Industrial Series Mechanical Drawing: Notes: 1) All dimensions in (mm). 2) 2.5mm barrel connector shown, other options are available. 3) The unit should not be covered or enclosed to protect against excessive case temperature rise. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: www.slpower.com TE60 Rev 2.7 25-APR-16 4 TE60 60W Single Output External Power Test & Measurement/Industrial Series Efficiency Level VI Information: TE60A 12V-48V TE60A 5V Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE60 Rev 2.7 25-APR-16 5