TE120 Datasheet

TE120
120W Single Output External Power
Test & Measurement/Industrial Series
Features

Meets DoE Efficiency Level VI Requirements


No load input power
Average Efficiency

Up to 120W of AC-DC Power

Universal Input 90-264Vac Input Range

IPX-2 Rated Enclosure for protection against
liquid ingress

Meets “Heavy Industrial” Levels of EN61000
EMC Requirements

Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin

Approved to EN/IEC/UL60950-1, 2nd Edition,
Am. 2

E-cap life of >7 years

3 Year Warranty

RoHS/REACH Compliant
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial
levels of various EN61000-4-x standards for EMC. The TE120 series models also meet Class B conducted and radiated
EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment
and other industrial applications.
Model Selection
Model
Number
Volts
Output
Current
Output
Power
Ripple &
Noise¹
Line
Regulation
Load
Regulation
TE120A1251F01
12.0V
10.0A
120W
120mV pk-pk
±1%
±5%
TE120A1803F01
18.0V
6.67A
120W
180mV pk-pk
±1%
±5%
TE120A2403F01
24.0V
5.00A
120W
240mV pk-pk
±1%
±5%
TE120A1251N01
12.0V
10.0A
120W
120mV pk-pk
±1%
±5%
TE120A1803N01
18.0V
6.67A
120W
180mV pk-pk
±1%
±5%
TE120A2403N01
24.0V
5.00A
120W
240mV pk-pk
±1%
±5%
TE120A1251Q01
12.0V
10.0A
120W
120mV pk-pk
±1%
±5%
TE120A1803Q01
18.0V
6.67A
120W
180mV pk-pk
±1%
±5%
TE120A2403Q01
24.0V
5.00A
120W
240mV pk-pk
±1%
±5%
Notes:
Output Cable
& Connector
4 cond. #18AWG; 6 pin
Molex Type conn.2
4 cond. #18AWG; 2.5 x 5.5
x 9.5mm Straight Barrel
Type conn., center positive
4 cond. #18AWG; 6 pin
Molex Type conn.2
4 cond. #18AWG; 2.5 x 5.5
x 9.5mm Straight Barrel
Type conn., center positive
4 cond. #18AWG; 6 pin
Molex Type conn.2
4 cond. #18AWG; 2.5 x 5.5
x 9.5mm Straight Barrel
Type conn., center positive
Input
Configuration
Class I Desktop,
IEC60320 C14
Receptacle
Class II Desktop,
IEC60320 C8
Receptacle
Class II Desktop,
IEC60320 C18
Receptacle
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors.
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE120B1251F01).
4. All specifications are typical at nominal input, full load, at 25C ambient unless noted.
5. Other connector options available, contact factory, or visit www.slpower.com.
www.slpower.com
TE120 Rev 1.2
16-MAY-16
PRELIMINARY
1
TE120
120W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 1 sec @115Vac, full load.
100Vac: 1.5A, 230Vac: 0.7A
Hold-up Time
20mS min., at full Load, 100Vac input
F1, F2: 3.15A, 250Vac fuses (line & neutral
lines) provided on all models
Short Circuit
Protection
Overvoltage
Protection
Meets US DoE Efficiency Level VI average
efficiency levels
120W continuous – See models chart for
specific voltage model ratings.
No Load Input
Power
<0.210W per DoE Efficiency Level VI
Requirements
Output Voltage
Overload Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Output Power
Ripple and Noise
Overtemperature
Protection
264Vac, cold start: will not exceed 40A peak
Isolation
Safety Standards
Operating
Temperature
See models chart on pg 1.
Case Temperature
See models chart on pg 1.
Transient
Response
500µs response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Temperature
Derating
E-Cap Life
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day. (80% load on 12V model)
MTBF
Weight
Safety Drop Test
Dimensions
Vibration
Storage Temperature
710g
1.4m from table top to wooden platform, 6
faces.
W: 2.65” x L: 8.3” x H: 1.7”
W: 67.4mm x L: 212.4mm x H: 44.25mm
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Altitude
Relative Humidity
Shock
Will shutdown upon an over-temperature
condition, auto-recovery.
130 to 180% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
130 to 150% of output voltage (max. 60V on
48V model), hiccup mode
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
-20°C to +50°C. Derate above 50 deg C.
Case Temperatures are within regulatory
guidelines. Power Supply unit should not be
covered or enclosed to ensure proper heat
dissipation.
See Derating Curve.
>250,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
-40°C to +85°C
Operating: to 5000m (derate to TBD temp.
above 3000m).
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 50G, Pulse duration of 6 mS,
Number of shocks: 3 for each of the three
axis
All specifications are typical at nominal input, full load, at 25C ambient unless noted.
www.slpower.com
TE120 Rev 1.2
16-MAY-16
PRELIMINARY
2
TE120
120W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions:
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions:
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise:
High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz
and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
Mechanical Drawing (12V Model:
Output Connector: 6 pin Molex 39-01-2060 or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC
www.slpower.com
TE120 Rev 1.2
16-MAY-16
PRELIMINARY
3
TE120
120W Single Output External Power
Test & Measurement/Industrial Series
Mechanical Drawing (18V, 24V models):
Output Connector: 2.5 x 5.5 x 9.5mm straight barrel type, center positive.
Notes:
1) All dimensions in mm.
2) Other connector options available. See below.
3) The unit should not be covered or enclosed to protect against excessive case temperature rise.
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. (#51 for the 12V models). Other
standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below:
www.slpower.com
TE120 Rev 1.2
16-MAY-16
PRELIMINARY
4
TE120
120W Single Output External Power
Test & Measurement/Industrial Series
Deratring Curve:
TE120 Series Derating Curve
All Models
Output Power (Watts)
140
120
100
80
60
40
20
0
-20°
-10°
0°
10°
20°
30°
40°
50°
60°
70°
Ambient Operating Temperature (°C)
Efficiency Level VI Information:
TE120 Series
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE120 Rev 1.2
16-MAY-16
PRELIMINARY
5