TE90 90W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 90W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets “Heavy Industrial” Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2nd Edition, Am. 2 E-cap life of >7 years 3 Year Warranty RoHS/REACH Compliant Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE90 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22, with margin. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Number TE90A1251F01 TE90A1503F01 TE90A1803F01 TE90A2403F01 TE90A1251N01 TE90A1503N01 TE90A1803N01 TE90A2403N01 TE90A1251Q01 TE90A1503Q01 TE90A1803Q01 TE90A2403Q01 Notes: Volts 12.0V 15.0V 18.0V 24.0V 12.0V 15.0V 18.0V 24.0V 12.0V 15.0V 18.0V 24.0V Output Current 7.50A 6.00A 5.00A 3.75A 7.50A 6.00A 5.00A 3.75A 7.50A 6.00A 5.00A 3.75A Output Power 90W 90W 90W 90W 90W 90W 90W 90W 90W 90W 90W 90W Ripple & Noise¹ 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk Line Regulation ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% Load Regulation ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Output Cable & Connector 6 pin Molex Type2 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Input Configuration Class I Desktop, IEC60320 C14 Receptacle 6 pin Molex Type2 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C8 Receptacle 6 pin Molex Type2 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C18 Receptacle 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE90B1251F01). 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE90 Rev 2.1 25-APR-16 1 TE90 90W Single Output External Power Test & Measurement/Industrial Series General Specifications AC Input Input Current Inrush Current Input Fuses Earth Leakage Current Efficiency 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 1 sec @115Vac, full load 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Protection 264Vac, cold start: will not exceed 60A F1, F2: 5A, 250Vac fuses (line & neutral lines) provided on all models Overload Protection Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Protection Overvoltage Protection Meets US DoE Efficiency Level VI average efficiency levels Output Power 90W continuous – See models chart for specific voltage model ratings. No Load Input Power <0.210W per DoE Efficiency Level VI Requirements Isolation Safety Standards Ripple and Noise See models chart on pg 1. Operating Temperature Output Voltage See models chart on pg 1. Case Temperature Transient Response E-Cap Life Weight Safety Drop Test Dimensions 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12V model) Temperature Derating MTBF Storage Temperature 600g 1.4m from table top to wooden platform, 6 faces. Altitude W: 2.58” x L: 5.9” x H: 1.34” W: 65.5mm x L: 150.5mm x H: 34mm Relative Humidity Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per Vibration axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE90 Rev 2.1 25-APR-16 Shock Will shutdown upon an over-temperature condition, auto-recovery. 130 to 180% of rating, Hiccup Mode Hiccup Mode, auto recovery. 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 -20°C to +70°C. Derate above 40°C. Case Temperatures are within regulatory guidelines. Care should be taken to avoid prolonged contact with skin or other heat sensitive surfaces. See Derating Chart >500,000 hours, full load, 110 & 220Vac input, 25°C amb., per Telcordia 332 Issue 6. -40°C to +85°C Operating: to 5000m (derate to TBD temp. above 3000m). Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis 2 TE90 90W Single Output External Power Test & Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20mS at 0 degrees. Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation D – Permanent damage Derating Chart: 100 90 Output Power - Wwatts 80 70 60 50 12V-24V 40 30 20 10 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature - ͦC www.slpower.com TE90 Rev 2.1 25-APR-16 3 TE90 90W Single Output External Power Test & Measurement/Industrial Series Mechanical Drawing: 65.5±0.5 34±0.5 Notes: 34±0.5 150.5±0.5 150.5±0.5 65.5±0.5 15V through 24V Models: 2.5 x 5.5 x 9.5mm Barrel Connector, center positive. 1) All dimensions in mm. 2) The unit should not be covered or enclosed to protect against excessive case temperature rise. 12V Models: Output Connector: 6 pin Molex 39-01-2060 or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. (#51 for the 12V models). Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: www.slpower.com TE90 Rev 2.1 25-APR-16 4 TE90 90W Single Output External Power Test & Measurement/Industrial Series Efficiency Level VI Information: TE90A Series Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE90 Rev 2.1 25-APR-16 5