TE90 DS

TE90
90W Single Output External Power
Test & Measurement/Industrial Series
Features

Meets DoE Efficiency Level VI Requirements


No load input power
Average Efficiency

Up to 90W of AC-DC Power

Universal Input 90-264Vac Input Range

IP22 Rated Enclosure

Meets “Heavy Industrial” Levels of EN61000
EMC Requirements

Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin

Approved to EN/IEC/UL60950-1, 2nd Edition,
Am. 2

E-cap life of >7 years

3 Year Warranty

RoHS/REACH Compliant
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial
levels of various EN61000-4-x standards for EMC. The TE90 series models also meet Class B conducted and radiated
EMI per FCC Part 15, EN55022, CISPR22, with margin. Designed to allow easy integration with test and measurement
equipment and other industrial applications.
Model Selection
Model
Number
TE90A1251F01
TE90A1503F01
TE90A1803F01
TE90A2403F01
TE90A1251N01
TE90A1503N01
TE90A1803N01
TE90A2403N01
TE90A1251Q01
TE90A1503Q01
TE90A1803Q01
TE90A2403Q01
Notes:
Volts
12.0V
15.0V
18.0V
24.0V
12.0V
15.0V
18.0V
24.0V
12.0V
15.0V
18.0V
24.0V
Output
Current
7.50A
6.00A
5.00A
3.75A
7.50A
6.00A
5.00A
3.75A
7.50A
6.00A
5.00A
3.75A
Output
Power
90W
90W
90W
90W
90W
90W
90W
90W
90W
90W
90W
90W
Ripple &
Noise¹
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
Line
Regulation
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Output Cable
& Connector
6 pin Molex Type2
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Input
Configuration
Class I Desktop,
IEC60320 C14
Receptacle
6 pin Molex Type2
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C8
Receptacle
6 pin Molex Type2
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C18
Receptacle
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors.
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE90B1251F01).
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE90 Rev 2.1
25-APR-16
1
TE90
90W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 1 sec @115Vac, full load
115Vac: 1.2A, 230Vac: 0.6A
Hold-up Time
20mS min., at full Load, 100Vac input
Overtemperature
Protection
264Vac, cold start: will not exceed 60A
F1, F2: 5A, 250Vac fuses (line & neutral lines)
provided on all models
Overload Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Short Circuit
Protection
Overvoltage
Protection
Meets US DoE Efficiency Level VI average
efficiency levels
Output Power
90W continuous – See models chart for
specific voltage model ratings.
No Load Input
Power
<0.210W per DoE Efficiency Level VI
Requirements
Isolation
Safety Standards
Ripple and Noise
See models chart on pg 1.
Operating
Temperature
Output Voltage
See models chart on pg 1.
Case Temperature
Transient
Response
E-Cap Life
Weight
Safety Drop Test
Dimensions
500µs response time for return to within 0.5%
of final value for any 50% load step over the
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day. (80% load on 12V model)
Temperature
Derating
MTBF
Storage Temperature
600g
1.4m from table top to wooden platform, 6
faces.
Altitude
W: 2.58” x L: 5.9” x H: 1.34”
W: 65.5mm x L: 150.5mm x H: 34mm
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Non-Oper.: random waveform, 3 minutes per
Vibration axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE90 Rev 2.1
25-APR-16
Shock
Will shutdown upon an over-temperature
condition, auto-recovery.
130 to 180% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
130 to 150% of output voltage (max. 60V on
48V model), hiccup mode
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
-20°C to +70°C. Derate above 40°C.
Case Temperatures are within regulatory
guidelines. Care should be taken to avoid
prolonged contact with skin or other heat
sensitive surfaces.
See Derating Chart
>500,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
-40°C to +85°C
Operating: to 5000m (derate to TBD temp.
above 3000m).
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
2
TE90
90W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions:
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
Radiated Emissions:
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
Common Mode Noise:
High Frequency (100kHz-20MHz): <40mA pk-pk
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
Radiated RF EM Fields Susceptibility
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz
and 80Mhz, 80% AM at 1KHz
Rated Power frequency magnetic fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
Voltage Interruptions, Dips, Sags &
Surges
EN55024/IECEN61000-4-11:
--100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20mS at 0 degrees.
Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
--30% dip for 500mS, Criteria A
Harmonic Current Emissions
EN55011/EN61000-3-2, Class A
Flicker Test
EN61000-3-3
Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following:
A – Normal performance during and after the test
B – Temporary degradation, self-recoverable
C – Temporary degradation, operator intervention required to recover the operation
D – Permanent damage
Derating Chart:
100
90
Output Power - Wwatts
80
70
60
50
12V-24V
40
30
20
10
0
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperature - ͦC
www.slpower.com
TE90 Rev 2.1
25-APR-16
3
TE90
90W Single Output External Power
Test & Measurement/Industrial Series
Mechanical Drawing:
65.5±0.5
34±0.5
Notes:
34±0.5
150.5±0.5
150.5±0.5
65.5±0.5
15V through 24V Models: 2.5 x 5.5 x 9.5mm
Barrel Connector, center positive.
1) All dimensions in mm.
2) The unit should not be covered or enclosed to protect against excessive case temperature rise.
12V Models: Output Connector: 6 pin Molex 39-01-2060
or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. (#51 for the 12V models). Other
standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below:
www.slpower.com
TE90 Rev 2.1
25-APR-16
4
TE90
90W Single Output External Power
Test & Measurement/Industrial Series
Efficiency Level VI Information:
TE90A Series
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE90 Rev 2.1
25-APR-16
5