Flushline™ Entrances - Architectural Detail Manual

FlushlineTM Entrances
MARCH, 2016
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-090
FEATURES
Hurricane Resistant Product
Blast Mitigation Product
Features
• Flush appearance with face sheet of aluminum or fiberglass reinforced polyester (FRP)
that is captured on four sides by integral extruded reglets
• Door is 1-3/4" (44.5 mm) Deep
• Dual moment welded corner construction
• Internal 500 wide stile frame has 5" (127 mm) vertical stiles, 5" (127 mm) top rail and
5" (127 mm) bottom rail
• Urethane foam core
• Single acting
• Vision lite infills of 1/4" (6.4 mm), 1" (25.4 mm) or 1" (25.4 mm) impact infill
• Offset pivots, butt hinges or continuous geared hinge
• MS locks or exit device hardware
• Surface mounted or concealed closers
• Architects Classic push/pulls
• Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles
• Polymeric bulb weatherstripping in door frames
• Aluminum panels with two texture choices, smooth and embossed
• FRP Pebble texture panel finishes in four standard choices
• PermanodicTM anodized finishes in seven choices
Optional Features
• PanelineTM exit device or PanelineTM EL exit device
• Large Missile, Small Missile and Hurricane Impact tested
• Blast Mitigation tested
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
• Painted finishes in standard and custom choices
Product Applications
• FlushlineTM is designed for high traffic applications such as schools, universities as
well as highly corrosive environments such as coastal applications, manufacturing
facilities and waste water treatment plants
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMA060EN
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FlushlineTM Entrances
MARCH, 2016
BLANK PAGE
EC 97911-090
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
INDEX
FINISH CHART..................................................................................... 4
PICTORIAL VIEW................................................................................. 5
SECTION DIMENSIONS....................................................................... 6
CONSTRUCTION DETAILS............................................................. 7, 8
FACE SHEET OPTIONS....................................................................... 9
VISION LITE OPTIONS...................................................................... 10
FRAME ADAPTER..............................................................................11
STANDARD ENTRANCE PACKAGES��������������������������������������������� 12
ENTRANCE OFFERINGS.............................................................. 13-16
APPLICATION CRITERIA.................................................................. 16
PUSH/PULL HARDWARE.................................................................. 17
PANELINE™ EXIT DEVICE.......................................................... 18, 19
THERMAL CHARTS...................................................................... 20-28
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
FINISH CHART
EC 97911-090
Dark Bronze
Light Gray
White
ADMA060EN
#40 BRONZE
ANODIZED
SELECT ANODIZED OR PAINTED FINISH AS
REQUIRED
FRP - PEBBLE
Beige
•
•
•
•
NOTE:
The finish chart depicts recommended color combinations of face sheet and door sub-frame.
Other combinations are available.
kawneer.com
© Kawneer Company, Inc., 2015
ALUMINUM
#17 CLEAR
ANODIZED
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FACE SHEET TYPE
AND FINISH
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
FINISH OF DOOR SUB-FRAME
PAINTED TO
MATCH
FlushlineTM Entrances
EC 97911-090
PICTORIAL VIEW
5
DOOR CONSTRUCTION
The chassis for Kawneer’s Flushline™ Series door utilizes Kawneer’s dual moment welded corner construction.
Face sheets interlock with the aluminum stiles and rails to create a hollow cavity which is then injected with urethane
foam. The exceptional characteristics of urethane foam assures a strong chemical bond with all internal aluminum
surfaces and a tough, dimensionally stable core. Doors are constructed with 5" (127 mm) wide stiles and rails internally
to support surface applied and mortised hardware. The pebble texture F.R.P. (Fiberglass Reinforced Polyester) face
sheet provides high impact resistance and architectural aesthetic qualities.
5" (127 mm) Vertical stile
Face sheets rabbeted into integral reglets
on stiles and rails
Sigma deep penetration plug welds and fillet welds
Mechanical fastening
Top rail cap
5" (127 mm) Top rail
© Kawneer Company, Inc., 2015
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MARCH, 2016
Aluminum face sheet
or
Fiberglass reinforced
polyester (FRP) face sheet
Injected urethane core
kawneer.com
ADMA060EN
5"
(127)
5"
(127)
TOP
ATTACHMENT
CL
OF CYL.
BOTTOM
OF DOOR
ADMA060EN
STANDARD
EXIT DEVICE
CL
PANIC LOCK
CYLINDER
2
BOTTOM
OF DOOR
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
CL OF CRASH BAR FOR
FALCON EXIT DEVICE
FlushlineTM Entrances
MARCH, 2016
SECTION DIMENSIONS
EC 97911-090
1
3
5"
(127)
2
kawneer.com
© Kawneer Company, Inc., 2015
3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
STANDARD
LOCATIONS
CL OF CRASH BAR FOR KAWNEER
STANDARD EXIT DEVICE
1
1690 = 41-9/16" (1055.7)
1790 = 41-9/16" (1055.7)
TOP
ATTACHMENT
1686 = 40" (1016)
1786 = 40" (1016)
STANDARD
LOCATIONS
41-9/16"
(1042.0)
44-5/16"
(1125.5)
40-13/16"
(1036.6)
44-5/16"
(1125.5)
6
SCALE 3" = 1'-0"
1-3/4"
(44.5)
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
CONSTRUCTION DETAILS
7
SCALE 3" = 1'-0"
NOTE: Details show TrifabTM VG 450 (Center) framing. FlushlineTM doors may be used with other Kawneer framing.
Refer to other framing sections for specific details.
6
4
1
3
3
OPP.
2
8
3
9
5
5
450501
450501
3
PIVOT STILE
1
LOCK STILE
2
MEETING STILES
450501
450502
450012
450033
8
TRANSOM
JAMB
7
TRANSOM
HEAD
4
TOP RAIL AT
HEADER
450022
GLASS STOPS
450502
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7
5
BOTTOM RAIL
6
TOP RAIL AT
TRANSOM BAR
9A
1" INFILL
9B
1" IMPACT INFILL
OPTIONAL
BOTTOM RAIL
WEATHERING
237795 3' (914.4) Sweep
237798 6' (1,828.8) Sweep
kawneer.com
9
1/4" INFILL
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
CONSTRUCTION DETAILS
EC 97911-090
SCALE 3" = 1'-0"
NOTE: Details show TrifabTM VG 450 (Center) framing. FlushlineTM doors may be used with other Kawneer framing.
Consult individual framing sections for details.
10
13
11
NOTE:
12
2
1
3
3
OPP.
5
Transom Panel
Maximum Size:
Single Door - 4'-0" x 3'-0"
Pairs of Doors - 8'-0" x 3'-0"
3
5
450502
237009
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
13
10
10
TRANSOM PANEL
HEAD
11
TOP RAIL AT
TRANSOM PANEL
12
TOP RAIL AT
TRANSOM PANEL
(FOR USE WITH
SURFACE CLOSER)
450501
13
JAMB AT
TRANSOM PANEL
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
237036
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
8
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
FACE SHEET OPTIONS
ALUMINUM DOOR FACE SHEETS
FOR EXTERIOR AND INTERIOR SURFACES
Smooth (Unpatterned)
Aluminum Sheet
0.090 (2.3) Thick
kawneer.com
Embossed Aluminum Sheet
0.090 (2.3) Thick
FRP DOOR FACE SHEETS
FOR EXTERIOR AND INTERIOR SURFACES
F.R.P. (Fiberglass Reinforced Polyester)
0.090 (2.3) Thick
Pebble Texture
Available Finishes:
Beige, Dark Bronze, Light Gray and White
ADMA060EN
9
10
FlushlineTM Entrances
MARCH, 2016
VISION LITE OPTIONS
EC 97911-090
STANDARD CONFIGURATIONS SHOWN
Consult your Kawneer representative for vision lites other than configurations shown.
ALUMINUM FRAMED VISION LITES
1" INFILL
1/4" INFILL
1" IMPACT INFILL
7" *
6"
(152.4)
32"
Width
12" (304.8)
6" (152.4)
22" (558.8)
6" (152.4)
Height
12" (304.8)
62" (1574.8)
32" (812.8)
32" (812.8)
Centered
Lock Side
Centered
Lock Side
Placement in Door
Minimum Edge
Dimension
7" (177.8) Top and Sides of Door
12" (304.8) Bottom of Door
* Edge dimensions shown are minimum allowed due to manufacturing constraints.
Please specify dimension "X" [Bottom of Door to Bottom of Vision Lite. Minimum dimension 12" (304.8)].
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Vision Lite
Size
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
"X"
"X"
"X"
32"
62"
(1574.8)
(177.8)
(812.8)
(558.8)
(812.8)
12"
"X"
7" *
(152.4)
22"
(177.8)
7" *
6"
(177.8)
7" *
7" *
(177.8)
(177.8)
(304.8)
(304.8)
(177.8)
7" *
12"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/4" GLASS, 1" INSULATING GLASS or 1" IMPACT GLASS
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
FRAME ADAPTER
11
4
3/8"
1/8"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
The FlushlineTM Frame Adapter is an economical answer for remodel/retrofit projects where new entrance doors are
being installed into existing frames. The FlushlineTM Frame Adapter utilizes polymeric bulb weathering for a resistive
weatherseal on three sides of the door. When the frame adapter is used in conjuction with a continuous hinge the need
for existing frame tear-out and attempting to align hardware on a new door with an existing frame is eliminated.
1
237430
2
3
1
HEAD
237430
2
HINGE JAMB
3
LOCK JAMB
237431
237430
237430
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
237430
4
CORNER ASSEMBLY
kawneer.com
ADMA060EN
3/8"
1/8"
1/8"
(3.2)
ADMA060EN
MASONRY OPENING
OVERALL FRAME
DOOR OPENING
3/32"
(2.4)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
FlushlineTM Entrances
MARCH, 2016
STANDARD ENTRANCE PACKAGES
EC 97911-090
OPTIONAL
BOTTOM RAIL
WEATHERING
237795 3' (914.4) Sweep
237798 6' (1,828.8) Sweep
kawneer.com
© Kawneer Company, Inc., 2015
1/8"
(3.2)
1/8"
(3.2)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/16"
(4.3)
OVERALL FRAME
3/32"
(2.4)
1/2"
(12.7)
DOOR OPENING
MASONRY OPENING
12
SCALE 3" = 1' 0"
DIMENSIONS ARE NOMINAL
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
ENTRANCE OFFERINGS
WITHOUT TRANSOM
Door Opening Dimension
3' 0" x 7' 0" (914 x 2134)
3' 6" x 7' 0" (1067 x 2134)
6' 0" x 7' 0" (1829 x 2134)
Overall Frame Dimension
3' 3-1/2" x 7' 1-3/4" (1003 x 2178)
3' 9-1/2" x 7' 1-3/4" (1156 x 2178)
6' 3-1/2" x 7' 1-3/4" (1918 x 2178)
Masonry Opening Dimension
3' 4-1/4" x 7' 2-1/8" (1022 x 2188)
3' 10-1/4" x 7' 2-1/8" (1175 x 2188)
6' 4-1/4" x 7' 2-1/8" (1937 x 2188)
WITH TRANSOM
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 1-3/4" (959) to above heights.
Masonry Opening Dimension
Add 3' 2-1/8" (968) to above heights.
WITH TRANSOM PANEL
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 1-3/4" (959) to above heights.
Masonry Opening Dimension
Add 3' 2-1/8" (968) to above heights.
STANDARD SIZES (TRIFABTM VG 451 CENTER FRAMES)
WITHOUT TRANSOM
Door Opening Dimension
3' 0" x 7' 0" (914 x 2134)
3' 6" x 7' 0" (1067 x 2134)
6' 0" x 7' 0" (1829 x 2134)
Overall Frame Dimension
3' 4" x 7' 2" (1016 x 2185)
3' 10" x 7' 2" (1168 x 2185)
6' 4" x 7' 2" (1930 x 2185)
Masonry Opening Dimension
3' 4-3/4" x 7' 2-3/8" (1035 x 2194)
3' 10-3/4" x 7' 2-3/8" (1187 x 2194)
6' 4-3/4" x 7' 2-3/8" (1949 x 2194)
WITH TRANSOM
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 2" (965) to above heights.
Masonry Opening Dimension
Add 3' 2-3/8" (975) to above heights.
WITH TRANSOM PANEL
Door Opening Dimension
Unchanged from above.
Overall Frame Dimension
Add 3' 2" (965) to above heights.
Masonry Opening Dimension
Add 3' 2-3/8" (975) to above heights.
STANDARD SIZES (FLUSHLINE™ FRAME ADAPTER)
WITHOUT TRANSOM
Door Opening Dimension
3' 0" x 7' 0" (914 x 2134)
3' 6" x 7' 0" (1067 x 2134)
6' 0" x 7' 0" (1829 x 2134)
Overall Frame Dimension
3' 0-3/4" x 7' 0-3/8" (933 x 2143)
3' 6-3/4" x 7' 0-3/8" (1086 x 2143)
6' 0-3/4" x 7' 0-3/8" (1848 x 2143)
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD SIZES (TRIFABTM 400 & TRIFABTM VG 450 CENTER FRAMES)
kawneer.com
ADMA060EN
13
FlushlineTM Entrances
MARCH, 2016
EC 97911-090
HINGING
OPTIONS
GLAZING STOP
OPTIONS
GLASS
THICKNESS
Single 3'-6" x 7'-6" (1066.8 x 2286)
Pair 7'-0" x 7'-6" (2133.6 x 2286)
± 70 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1
1" (25.4)
Kawneer 1686
Concealed Rod
Exit Device
(EL option)
Single 3'-6" x 7'-6" (1066.8 x 2286)
Pair 7'-0" x 7'-6" (2133.6 x 2286)
± 70 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1
1" (25.4)
Corbin Russwin
ED5200S
Rim Device
Single 3'-6" x 7'-6" (1066.8 x 2286)
Pair 7'-0" x 7'-6" (2133.6 x 2286)
± 50 PSF
(Zone 3 only)
Offset Pivots
Butt Hinges
Continuous Hinge
1
1" (25.4)
Schage L9453P
Mortise Lock
Single 3'-6" x 7'-6" (1066.8 x 2286)
Pair 8'-0" x 8'-0" (2438.4 x 2438.4)
± 75 PSF
Offset Pivots
Butt Hinges
Continuous Hinge
1
1" (25.4)
HINGING
OPTIONS
GLAZING STOP
OPTIONS
GLASS
THICKNESS
Offset Pivots
Butt Hinges
1
1" (25.4)
Offset Pivots
Butt Hinges
1
1" (25.4)
MS 1850
3-Point Lock
(Active leaf)
Flushbolts
(Inactive leaf)
MAXIMUM
DOOR SIZE
Glazing Stop Options:
1 - Structural silicone with 0.090 Kuraray or Eastman PVB inter layer.
ENTRANCE HARDWARE OFFERINGS
Blast Mitigation Product
LOCKING
OPTIONS
MS 1850
3-Point Lock
(Active leaf)
Flushbolts
(Inactive leaf)
Schage L9453P
Mortise Lock
MAXIMUM
DOOR SIZE
Single 3'-6" x 6'-6" (1066.8 x 1981.2)
Pair 7'-0" x 6'-6" (2133.6 x 1981.2)
Single 3'-6" x 6'-6" (1066.8 x 1981.2)
MAXIMUM
BLAST
LOADING
Peak Pressure:
4 PSI
Impulse:
28 PSI•MSEC
Peak Pressure:
4 PSI
Impulse:
28 PSI•MSEC
Test conditions shown. Other conditions may be supported through calulation.
Glazing Stop Options:
1 - Structural silicone with 0.060 Kuraray or Eastman PVB inter layer.
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
MAXIMUM
DESIGN
PRESSURE
LOCKING
OPTIONS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
ENTRANCE HARDWARE OFFERINGS
Hurricane Resistant Product
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
ENTRANCE OFFERINGS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD
15
OPTIONAL
Doors
Flushline™ doors prepared for attachment hardware.
Door Sizes Std.
Standard sizes shown on page 12.
Any size up to 4'-0" x 8'-0" (1219 x 2438).
Glass Stops
Vision Lite for 1/4" (6.4) or 3/16" (4.0) infill.
Vision Lite for 1" (25.4) infill.
Vision Lite for 1" (25.4) impact infill.
Door Frames
TrifabTM 400 - 1-3/4" x 4" (44.5 x 101.6) for single glazing.
Any Kawneer framing system suitable for door frames may be
selected, but manufactured per order.
Trifab VG 450 Center - 1-3/4" x 4-1/2" (44.5 x 114.3) for
single glazing.
TM
TrifabTM VG 451 Center - 2" x 4-1/2" (50.8 x 114.3) for double
glazing.
Push-Pulls
Single Acting:
Architects Classic Hardware "CO-9" Pull
and "CP-II" Push Bar.
Single Acting:
Architects Classic Hardware "CO-9" Pull
and "CP" Push Bar.
Architects Classic Hardware
"CO-12" and "CP-II" push bar.
Architects Classic Hardware
"CO-12" and "CP" push bar.
Architects Classic Hardware
"CO-9"/"CO-9" Pulls.
Architects Classic Hardware
"CO-12"/"CO-12" Pulls
Recessed Pull
Door Closers
Single Acting:
Norton 1601 adjustable or 1601 BF
adjustable surface closer with back-check
and with or without adjustable hold-open.
Standard concealed overhead closer with
single acting offset arm.
Single Acting:
LCN 4040 surface closer with or without
adjustable hold-open.
LCN 2010, 2030 or 5010 concealed
overhead closers with or without hold-open.
LCN 1260 adjustable surface closer.
Norton 8100 surface closer with a 50%
spring power adjustment (for opening forces
of less than 8 pounds). Closer is available
with standard back-checks and with or
without the hold-open feature.
Falcon SC 60 surface closer.
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
International single acting concealed
overhead closer.
Hinging
Single Acting:
Kawneer top and bottom offset pivots
(or) Kawneer top and bottom 4 1/2" x 4"
(114.3 x 101.6) ball bearing butt hinge with
non-removable pin (NRP) (or) Kawneer
continuous gear hinge.
Intermediate
Pivots/Butts
Single Acting:
Rixson M-19 or IVES #7215-INT
intermediate offset pivot (or)
Kawneer 4-1/2" x 4" (114.3 x 101.6) ball
bearing butt hinge with non-removable pin
(NRP).
Power
Transfers
Single Acting:
Rixson M-19 EL or IVES #7215-INT
intermediate offset pivot (or)
Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball
bearing butt hinge with wire transfer (or)
EPT (Electric Power Transfer).
Power Supply
SP-1000X Power Supply: For use with PanelineTM EL exit
devices.
PS1, PS5-4, and PS5-6 Power Supplies: For use with
Kawneer 1686 EL and 1786 EL exit devices only.
Locks Active Leaf
Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4)
diameter 5 pin cylinders.
Adams-Rite #4510 latch lock.
Adams-Rite #1850A-020 short throw deadlock.
Adams-Rite #1850A-050 hookbolt lock.
Adams-Rite #4015 two-point Lock.
Adams-Rite #4085 three-point Lock.
Adams-Rite #4089 exit indicator.
Kawneer cylinder guard.
Kawneer thumbturn (in lieu of cylinder).
Schlage L9453P mortise lock.
Yale 8860 mortise lock.
Yale 5407 knob lock.
Corbin Russwin CK4451 knob lock.
kawneer.com
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
ENTRANCE OFFERINGS/APPLICATION CRITERIA
EC 97911-090
OPTIONAL
One pair of Kawneer flush bolts in the
inactive leaf of a pair of doors.
Thresholds
A 1/2" x 4" (12.7 x 101.6) aluminum mill
finish threshold.
A 1/2" x 6-3/4" (12.7 x 171.5) aluminum mill finish threshold.
Weathering
Single
Acting:
Bottom Door Sweep
Exit Device
Kawneer 1686 Concealed Rod Exit
Device with or without a mortised type
cylinder.
Kawneer 1786 Rim Exit Device is a rim
type exit device with or without a rim type
cylinder. Pairs of doors require a Kawneer
RM-86 removable mullion.
PanelineTM exit device is a concealed rod
exit device applicable to single or pairs
of doors. It features an activating panel
contained within the door cross rail.
Exit Device Pulls:
Architects Classic style "CO-9" Pull with
Kawneer 1686 and 1786 exit devices.
Architects Classic style "CO9" Pull
for PanelineTM and PanelineTM EL exit
devices.
Kawneer 1686 EL Concealed Rod Exit Device electric modification is available.
Kawneer 1786 EL Rim Exit Device electric modification is available.
Kawneer 1686 CD Concealed Rod Exit Device available with cylinder dogging.
Kawneer 1786 CD Rim Exit Device available with cylinder dogging.
Kawneer 1686 Lever Handle is available for the Kawneer 1686 concealed rod exit
device.
Kawneer 1786 Lever Handle is available for the Kawneer 1786 rim type exit device.
Falcon 1690 Concealed Rod Exit Device with or without a mortised type cylinder.
Falcon 1790 Rim Exit Device is a rim type exit device with or without a rim type
cylinder.
Falcon EL 1690 electric modification is also available.
Falcon EL 1790 electric modification is also available
PanelineTM EL electric modification is also available.
Corbin Russwin ED5200S Rim Exit Device is a rim type exit device. Pairs of doors
require a removable mullion, WS707/708AKM.
Falcon 1990 is a concealed rod exit device with or without a rim type cylinder.
Falcon 2090 is a rim type exit device with or without a rim type cylinder. Pairs of doors
require a removable aluminum mullion. RM-70 with the Falcon 2090 exit device.
Optional Exit Device Pulls:
Architects Classic style "CO-12" Pull with Kawneer 1686 and 1786 exit devices.
APPLICATION CRITERIA
As indicated on page 13, the standard sizes of swing doors are 3'-0" x 7'-0" (914.4 x 2133.6) or 3'-6" x 7'-0" (1067 x 2134) for single doors and
6'-0" x 7'-0" (1828.8 x 2133.6) for pairs of doors. When these sizes are exceeded the following criteria should be administered.
1. Larger doors should not be subject to heavy traffic or strong prevailing wind conditions.
2. Larger doors should use a door closer with a good back check action.
3. When a door exceeds 9'-0" (2743.2) in height, a crossrail or push bar is recommended to reinforce the internal vertical stiles.
4. When an offset hung door exceeds 7'-6" (2286.0) in height, an intermediate butt or offset pivot should be used.
5. Tall doors should be prevented from racking by proper utilization of hardware, including door closers, door holders and door stops.
NOTE:
SOME OF THESE CRITERIA ARE OF A SUBJECTIVE
NATURE, CONTACT YOUR FACTORY REPRESENTATIVE
FOR APPLICATION ASSISTANCE.
MAXIMUM DOOR HEIGHT
FOR PANELINETM EL = 8'-0"
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Weathering system in the
door and frame consisting of a
dense, bulb polymeric material,
which remains resilient and
retains its weathering ability
under temperature extremes.
(The system is complete with
an optional EPDM blade gasket
sweep strip applied to the
bottom door rail with concealed
fasteners).
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
STANDARD
Locks Inactive Leaf
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
PUSH-PULL HARDWARE
17
REFER TO HARDWARE SECTION FOR COMPLETE HARDWARE INFORMATION.
ARCHITECTS CLASSIC (PUSH PULL SETS)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR AS STANDARD
CP-II/CP-II
CO-9/CO-9
CO-12/CO-12
CP/CP
CO-9/CP-II
CO-12 /CP-II
CO-9/CP
CO-12/CP
RECESSED PULL
ARCHITECTS CLASSIC (COMPONENTS)
STYLE CO-12
PULL
STYLE CO-9
PULL
EXIT DEVICES
STYLE CP PUSH BAR
STYLE CP-II PUSH BAR
EXIT DEVICES AND PULLS
9-5/16" OVERALL W/ STOPS
(236.5)
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
KAWNEER PANELINETM / PANELINETM EL
INTERIOR
VIEW
STYLE "CO-9"
PULL
STYLE"CO9" PULL ON
EXTERIOR OF DOOR
STYLE "CO-12"
PULL
RIM LATCH
Falcon 2090
CONCEALED ROD
Falcon 1990
CONCEALED ROD
Falcon 1690
Falcon EL 1690
RIM LATCH
Falcon 1790
Falcon EL 1790
RIM LATCH
Corbin Russwin
ED5200S
CONCEALED ROD
Kawneer 1686
Kawneer 1686 EL
Kawneer 1686 CD
RIM LATCH
Kawneer 1786
Kawneer 1786 EL
Kawneer 1786 CD
LEVER HANDLE
Kawneer 1686
Kawneer 1786
eer
Kawn
EXTERIOR VIEW OF FLUSHLINE™ DOOR
"CO9" PULL AND OPTIONAL CYLINDER GUARD SHOWN.
SEE PAGE 17 AND 18 FOR COMPLETE
PANELINETM INFORMATION
kawneer.com
ADMA060EN
18
FlushlineTM Entrances
MARCH, 2016
PANELINETM EXIT DEVICE
EC 97911-090
The PanelineTM concealed rod exit device for Flushline™ doors will accommodate variations in stile width and door width as shown
in the following illustrations. Sidelites adjacent to PanelineTM equipped doors not requiring exit devices may be fitted with fixed
panels as detailed below to match the general appearance of the PanelineTM cross rail.
The Optional PanelineTM EL device is designed for electrified access control and is compatible with most key pad and card reader
systems.
PanelineTM uses mortise cylinder in lieu of the normal rim-type.
Dummy PanelineTM units are not for use with any type of lock.
1 3/4"
(44.4)
3/16"
(4.7)
1 1/8"
(28.6)
INTERIOR ELEVATIONS
NOTE: Sidelites must be stop glazed above and below rail.
2
8 1/4"
(209.5)
2
3*
SIDELITE
CROSSRAIL
CROSSRAIL
WITH FIXED
PANEL
3*
SEE
NOTE
SIDELITE
36-1/8"
(917.6)
TO BOTTOM
OF DOOR
*VESTIBULE DOOR
(Without Exit Device or Lock)
CROSSRAIL
WITH EXIT DEVICE
AND CO9 PULL HANDLE
INTERIOR VIEW
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
ACTIVE DOOR
PANELINETM EL COMPONENTS
PIVOT STILE TRIM FILLER WIDTH
VARIES WITH DOOR WIDTH
PUSH
DOGGING LOCK
(TYPICAL)
6-9/32"
(159.5)
DOOR OPENING WIDTH
4'-0" (1219.2) MAX. - 3'-0" (914.4) MIN.
3'-0" (914.4) ADA MIN.
POWER TRANSFER
INTERMEDIATE BUTT HINGE
POWER TRANSFER
INTERMEDIATE OFFSET PIVOT
EXTERIOR VIEW
ELECTRIC POWER TRANSFER
(EPT)
ADMA060EN
SP-1000X POWER SUPPLY
kawneer.com
© Kawneer Company, Inc., 2015
1
1
PUSH
8"
(203.2)
PUSH
7 1/8"
(180.9)
SEE
NOTE
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
See Hardware Section for complete description of PanelineTM hardware, including finish of units.
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
PANELINETM EXIT DEVICE
19
Sidelites adjacent to PanelineTM equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general
appearance of the PanelineTM cross rail.
See Hardware Section for complete description of PanelineTM hardware, including finish of units.
1 3/4"
(44.4)
3/16"
(4.7)
1 1/8"
(28.6)
INTERIOR ELEVATION
NOTE: Sidelites must be stop glazed above and below rail.
1
PUSH
1 OR 3*
8 1/4"
(209.5)
PUSH
8"
(203.2)
SEE NOTE
7 1/8"
(180.9)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PanelineTM uses mortise cylinder in lieu of the normal rim-type.
Dummy PanelineTM units should not use any type of lock.
2
3*
SIDELITE
CROSSRAIL
CROSSRAIL
WITH FIXED
PANEL
2
1 OR 3*
SEE NOTE
INACTIVE DOOR
ACTIVE DOOR
36-1/8"
(917.6)
TO BOTTOM
OF DOOR
SIDELITE
* ALTERNATE CROSSRAIL FOR VESTIBULE DOORS
(Without Exit Device or Lock)
CROSSRAIL
WITH EXIT DEVICE
AND CO9 PULL HANDLE
PIVOT STILE TRIM FILLER WIDTH
VARIES WITH DOOR WIDTH
PUSH
PUSH
DOGGING LOCK
(TYPICAL)
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
INTERIOR VIEW
DOOR OPENING WIDTH
8'-0" (2438.4) MAX. - 6'-0" (1828.8) MIN.
6'-0" (1828.8) ADA MIN.
STYLE"CO9" PULL ON
EXTERIOR OF DOOR
EXTERIOR VIEW
WITH "CO9" PULL AND STANDARD CYLINDER GUARD SHOWN
kawneer.com
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
THERMAL CHARTS
EC 97911-090
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
"X"
(F.H.)
32"
(812.8)
(DLO)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7"
(177.8)
22"
(558.8)
(DLO)
7' 1-3/4"
(2178.1)
3' 3-1/2"
(1003.3)
(F.W.)
Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F
Total Daylight Opening
= 22" x 32" = 4.89 ft2
Total Projected Area
= 3' 3-1/2" x 7' 1-3/4" = 23.52 ft2
Percent of Glass
= (Total Daylight Opening ÷ Total Projected Area)100
= (4.89 ÷ 23.52)100 = 21%
System U-factor vs Percent of Glass Area
0.90
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.85
0.40 (2.27)
0.36 (2.05)
0.34 (1.93)
0.30 (1.71)
O
E IGN
PL S
M E
A D
EX FOR
N
0.32 (1.82)
0.28 (1.59)
0.80
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
Btu
hr • ft2 • °F
System U-factor
T
0.26 (1.48)
0.75
0.74
0.70
42
37
32
27
22
Percent of Glass Area
17
12
0.65
Based on 21% glass and center of glass (COG) U-factor of 0.28
System U-factor is equal to 0.74 Btu/hr • ft2 • °F
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.38 (2.16)
21%
20
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
THERMAL CHARTS
FLUSHLINETM DOOR WITH ALUMINUM SKIN
System U-factor vs Percent of Glass Area
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
0.90
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.85
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.80
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.18 (1.02)
0.16 (0.91)
0.75
0.12 (0.68)
0.10 (0.57)
0.70
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.14 (0.80)
42
37
32
27
22
17
12
0.65
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
ADMA060EN
System U-factor (BTU/hr·ft2·oF)
0.34 (1.93)
21
FlushlineTM Entrances
MARCH, 2016
THERMAL CHARTS
EC 97911-090
FLUSHLINETM DOOR WITH ALUMINUM SKIN
COG
SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
0.35
0.75
0.70
0.65
0.55
0.25
0.50
0.45
0.20
0.40
0.35
0.30
0.15
0.25
0.20
0.10
0.15
System SHGC
0.30
0.60
0.10
0.05
0.05
42
37
32
27
22
17
12
0.00
COG
VT
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System Visible Transmittance (VT) vs Percent of Vision Area
0.35
0.75
0.30
0.70
0.65
0.60
0.25
0.55
0.50
0.20
0.45
0.40
0.15
0.35
0.30
0.25
0.10
0.20
0.15
0.05
0.10
0.05
42
37
32
27
22
17
12
0.00
Vision Area / Total Area (%)
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Vision Area / Total Area (%)
System VT
22
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Single Door with Aluminum
Panel and 1/4 Vision Lite
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.74
0.46
0.74
0.44
0.73
0.42
0.73
0.40
0.73
0.38
0.73
0.36
0.73
0.34
0.72
0.32
0.72
0.30
0.72
0.28
0.72
0.26
0.71
0.24
0.71
0.22
0.71
0.20
0.71
0.18
0.70
0.16
0.70
0.14
0.70
0.12
0.70
0.10
0.69
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
23
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 1920mm wide by
2090mm high (75-1/2" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.12
0.75
0.09
0.70
0.12
0.70
0.08
0.65
0.11
0.65
0.08
0.60
0.10
0.60
0.07
0.55
0.10
0.55
0.07
0.50
0.09
0.50
0.06
0.45
0.09
0.45
0.05
0.40
0.08
0.40
0.05
0.35
0.07
0.35
0.04
0.30
0.07
0.30
0.04
0.25
0.06
0.25
0.03
0.20
0.05
0.20
0.02
0.15
0.05
0.15
0.02
0.10
0.04
0.10
0.01
0.05
0.04
0.05
0.01
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-090
Overall U-Factor 4
0.48
0.79
0.46
0.79
0.44
0.78
0.42
0.78
0.40
0.77
0.38
0.77
0.36
0.77
0.34
0.76
0.32
0.76
0.30
0.75
0.28
0.75
0.26
0.74
0.24
0.74
0.22
0.74
0.20
0.73
0.18
0.72
0.16
0.72
0.14
0.72
0.12
0.71
0.10
0.71
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.21
0.75
0.18
0.70
0.20
0.70
0.17
0.65
0.18
0.65
0.15
0.60
0.17
0.60
0.14
0.55
0.16
0.55
0.13
0.50
0.15
0.50
0.12
0.45
0.14
0.45
0.11
0.40
0.12
0.40
0.09
0.35
0.11
0.35
0.08
0.30
0.10
0.30
0.07
0.25
0.09
0.25
0.06
0.20
0.08
0.20
0.05
0.15
0.07
0.15
0.04
0.10
0.05
0.10
0.02
0.05
0.04
0.05
0.01
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Single Door with Aluminum
Panel and 1/2 Vision Lite
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
24
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
THERMAL CHARTS
FLUSHLINETM DOOR WITH FRP SKIN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-factor vs Percent of Glass Area
0.85
COG
U-factor
0.48 (2.73)
0.46 (2.61)
0.80
0.44 (2.50)
0.42 (2.39)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.75
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.70
0.18 (1.02)
0.16 (0.91)
0.14 (0.80)
0.12 (0.68)
0.10 (0.57)
0.65
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.20 (1.14)
42
37
32
27
22
17
12
0.60
Percent of Glass = Vision Area/Total Area
(Total Daylight Opening / Projected Area)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
kawneer.com
ADMA060EN
System U-factor (BTU/hr·ft2·oF)
0.40 (2.27)
25
FlushlineTM Entrances
MARCH, 2016
THERMAL CHARTS
EC 97911-090
FLUSHLINETM DOOR WITH FRP SKIN
COG
SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
0.35
0.75
0.70
0.65
0.30
0.55
0.25
0.50
0.45
0.20
0.40
0.35
0.30
0.15
0.25
0.20
0.10
0.15
System SHGC
0.60
0.10
0.05
0.05
42
37
32
27
22
17
12
0.00
COG
VT
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System Visible Transmittance (VT) vs Percent of Vision Area
0.35
0.75
0.30
0.70
0.65
0.60
0.25
0.55
0.50
0.20
0.45
0.40
0.15
0.35
0.30
0.25
0.10
0.20
0.15
0.05
0.10
0.05
42
37
32
27
22
17
12
0.00
Vision Area / Total Area (%)
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Vision Area / Total Area (%)
System VT
26
MARCH, 2016
FlushlineTM Entrances
EC 97911-090
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Single Door with FRP Panel
and 1/4 Vision Lite
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.67
0.46
0.67
0.44
0.66
0.42
0.66
0.40
0.66
0.38
0.66
0.36
0.66
0.34
0.65
0.32
0.65
0.30
0.65
0.28
0.65
0.26
0.64
0.24
0.64
0.22
0.64
0.20
0.64
0.18
0.63
0.16
0.63
0.14
0.63
0.12
0.63
0.10
0.62
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2015
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
27
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.12
0.75
0.09
0.70
0.11
0.70
0.08
0.65
0.11
0.65
0.08
0.60
0.10
0.60
0.07
0.55
0.09
0.55
0.07
0.50
0.09
0.50
0.06
0.45
0.08
0.45
0.05
0.40
0.08
0.40
0.05
0.35
0.07
0.35
0.04
0.30
0.06
0.30
0.04
0.25
0.06
0.25
0.03
0.20
0.05
0.20
0.02
0.15
0.05
0.15
0.02
0.10
0.04
0.10
0.01
0.05
0.03
0.05
0.01
ADMA060EN
FlushlineTM Entrances
MARCH, 2016
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
EC 97911-090
Overall U-Factor 4
0.48
0.72
0.46
0.72
0.44
0.71
0.42
0.71
0.40
0.70
0.38
0.70
0.36
0.69
0.34
0.69
0.32
0.69
0.30
0.68
0.28
0.68
0.26
0.67
0.24
0.67
0.22
0.66
0.20
0.66
0.18
0.65
0.16
0.65
0.14
0.64
0.12
0.64
0.10
0.64
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values
(winter conditions) and are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 960mm wide by
2090mm high (37-3/4" by 82-3/8").
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.20
0.75
0.18
0.70
0.19
0.70
0.17
0.65
0.18
0.65
0.15
0.60
0.17
0.60
0.14
0.55
0.16
0.55
0.13
0.50
0.15
0.50
0.12
0.45
0.13
0.45
0.11
0.40
0.12
0.40
0.09
0.35
0.11
0.35
0.08
0.30
0.10
0.30
0.07
0.25
0.09
0.25
0.06
0.20
0.07
0.20
0.05
0.15
0.06
0.15
0.04
0.10
0.05
0.10
0.02
0.05
0.04
0.05
0.01
ADMA060EN
kawneer.com
© Kawneer Company, Inc., 2015
Glass U-Factor 3
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Single Door with FRP Panel
and 1/2 Vision Lite
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
28