FlushlineTM Entrances MARCH, 2016 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-090 FEATURES Hurricane Resistant Product Blast Mitigation Product Features • Flush appearance with face sheet of aluminum or fiberglass reinforced polyester (FRP) that is captured on four sides by integral extruded reglets • Door is 1-3/4" (44.5 mm) Deep • Dual moment welded corner construction • Internal 500 wide stile frame has 5" (127 mm) vertical stiles, 5" (127 mm) top rail and 5" (127 mm) bottom rail • Urethane foam core • Single acting • Vision lite infills of 1/4" (6.4 mm), 1" (25.4 mm) or 1" (25.4 mm) impact infill • Offset pivots, butt hinges or continuous geared hinge • MS locks or exit device hardware • Surface mounted or concealed closers • Architects Classic push/pulls • Adjustable astragal utilizing pile weathering with polymeric fin at meeting stiles • Polymeric bulb weatherstripping in door frames • Aluminum panels with two texture choices, smooth and embossed • FRP Pebble texture panel finishes in four standard choices • PermanodicTM anodized finishes in seven choices Optional Features • PanelineTM exit device or PanelineTM EL exit device • Large Missile, Small Missile and Hurricane Impact tested • Blast Mitigation tested © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Painted finishes in standard and custom choices Product Applications • FlushlineTM is designed for high traffic applications such as schools, universities as well as highly corrosive environments such as coastal applications, manufacturing facilities and waste water treatment plants For specific product applications, Consult your Kawneer representative. kawneer.com ADMA060EN 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FlushlineTM Entrances MARCH, 2016 BLANK PAGE EC 97911-090 ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 MARCH, 2016 FlushlineTM Entrances EC 97911-090 INDEX FINISH CHART..................................................................................... 4 PICTORIAL VIEW................................................................................. 5 SECTION DIMENSIONS....................................................................... 6 CONSTRUCTION DETAILS............................................................. 7, 8 FACE SHEET OPTIONS....................................................................... 9 VISION LITE OPTIONS...................................................................... 10 FRAME ADAPTER..............................................................................11 STANDARD ENTRANCE PACKAGES��������������������������������������������� 12 ENTRANCE OFFERINGS.............................................................. 13-16 APPLICATION CRITERIA.................................................................. 16 PUSH/PULL HARDWARE.................................................................. 17 PANELINE™ EXIT DEVICE.......................................................... 18, 19 THERMAL CHARTS...................................................................... 20-28 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMA060EN FlushlineTM Entrances MARCH, 2016 FINISH CHART EC 97911-090 Dark Bronze Light Gray White ADMA060EN #40 BRONZE ANODIZED SELECT ANODIZED OR PAINTED FINISH AS REQUIRED FRP - PEBBLE Beige • • • • NOTE: The finish chart depicts recommended color combinations of face sheet and door sub-frame. Other combinations are available. kawneer.com © Kawneer Company, Inc., 2015 ALUMINUM #17 CLEAR ANODIZED Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FACE SHEET TYPE AND FINISH Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 FINISH OF DOOR SUB-FRAME PAINTED TO MATCH FlushlineTM Entrances EC 97911-090 PICTORIAL VIEW 5 DOOR CONSTRUCTION The chassis for Kawneer’s Flushline™ Series door utilizes Kawneer’s dual moment welded corner construction. Face sheets interlock with the aluminum stiles and rails to create a hollow cavity which is then injected with urethane foam. The exceptional characteristics of urethane foam assures a strong chemical bond with all internal aluminum surfaces and a tough, dimensionally stable core. Doors are constructed with 5" (127 mm) wide stiles and rails internally to support surface applied and mortised hardware. The pebble texture F.R.P. (Fiberglass Reinforced Polyester) face sheet provides high impact resistance and architectural aesthetic qualities. 5" (127 mm) Vertical stile Face sheets rabbeted into integral reglets on stiles and rails Sigma deep penetration plug welds and fillet welds Mechanical fastening Top rail cap 5" (127 mm) Top rail © Kawneer Company, Inc., 2015 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MARCH, 2016 Aluminum face sheet or Fiberglass reinforced polyester (FRP) face sheet Injected urethane core kawneer.com ADMA060EN 5" (127) 5" (127) TOP ATTACHMENT CL OF CYL. BOTTOM OF DOOR ADMA060EN STANDARD EXIT DEVICE CL PANIC LOCK CYLINDER 2 BOTTOM OF DOOR Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CL OF CRASH BAR FOR FALCON EXIT DEVICE FlushlineTM Entrances MARCH, 2016 SECTION DIMENSIONS EC 97911-090 1 3 5" (127) 2 kawneer.com © Kawneer Company, Inc., 2015 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. STANDARD LOCATIONS CL OF CRASH BAR FOR KAWNEER STANDARD EXIT DEVICE 1 1690 = 41-9/16" (1055.7) 1790 = 41-9/16" (1055.7) TOP ATTACHMENT 1686 = 40" (1016) 1786 = 40" (1016) STANDARD LOCATIONS 41-9/16" (1042.0) 44-5/16" (1125.5) 40-13/16" (1036.6) 44-5/16" (1125.5) 6 SCALE 3" = 1'-0" 1-3/4" (44.5) MARCH, 2016 FlushlineTM Entrances EC 97911-090 CONSTRUCTION DETAILS 7 SCALE 3" = 1'-0" NOTE: Details show TrifabTM VG 450 (Center) framing. FlushlineTM doors may be used with other Kawneer framing. Refer to other framing sections for specific details. 6 4 1 3 3 OPP. 2 8 3 9 5 5 450501 450501 3 PIVOT STILE 1 LOCK STILE 2 MEETING STILES 450501 450502 450012 450033 8 TRANSOM JAMB 7 TRANSOM HEAD 4 TOP RAIL AT HEADER 450022 GLASS STOPS 450502 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7 5 BOTTOM RAIL 6 TOP RAIL AT TRANSOM BAR 9A 1" INFILL 9B 1" IMPACT INFILL OPTIONAL BOTTOM RAIL WEATHERING 237795 3' (914.4) Sweep 237798 6' (1,828.8) Sweep kawneer.com 9 1/4" INFILL ADMA060EN FlushlineTM Entrances MARCH, 2016 CONSTRUCTION DETAILS EC 97911-090 SCALE 3" = 1'-0" NOTE: Details show TrifabTM VG 450 (Center) framing. FlushlineTM doors may be used with other Kawneer framing. Consult individual framing sections for details. 10 13 11 NOTE: 12 2 1 3 3 OPP. 5 Transom Panel Maximum Size: Single Door - 4'-0" x 3'-0" Pairs of Doors - 8'-0" x 3'-0" 3 5 450502 237009 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 13 10 10 TRANSOM PANEL HEAD 11 TOP RAIL AT TRANSOM PANEL 12 TOP RAIL AT TRANSOM PANEL (FOR USE WITH SURFACE CLOSER) 450501 13 JAMB AT TRANSOM PANEL ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 237036 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MARCH, 2016 FlushlineTM Entrances EC 97911-090 FACE SHEET OPTIONS ALUMINUM DOOR FACE SHEETS FOR EXTERIOR AND INTERIOR SURFACES Smooth (Unpatterned) Aluminum Sheet 0.090 (2.3) Thick kawneer.com Embossed Aluminum Sheet 0.090 (2.3) Thick FRP DOOR FACE SHEETS FOR EXTERIOR AND INTERIOR SURFACES F.R.P. (Fiberglass Reinforced Polyester) 0.090 (2.3) Thick Pebble Texture Available Finishes: Beige, Dark Bronze, Light Gray and White ADMA060EN 9 10 FlushlineTM Entrances MARCH, 2016 VISION LITE OPTIONS EC 97911-090 STANDARD CONFIGURATIONS SHOWN Consult your Kawneer representative for vision lites other than configurations shown. ALUMINUM FRAMED VISION LITES 1" INFILL 1/4" INFILL 1" IMPACT INFILL 7" * 6" (152.4) 32" Width 12" (304.8) 6" (152.4) 22" (558.8) 6" (152.4) Height 12" (304.8) 62" (1574.8) 32" (812.8) 32" (812.8) Centered Lock Side Centered Lock Side Placement in Door Minimum Edge Dimension 7" (177.8) Top and Sides of Door 12" (304.8) Bottom of Door * Edge dimensions shown are minimum allowed due to manufacturing constraints. Please specify dimension "X" [Bottom of Door to Bottom of Vision Lite. Minimum dimension 12" (304.8)]. ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Vision Lite Size Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. "X" "X" "X" 32" 62" (1574.8) (177.8) (812.8) (558.8) (812.8) 12" "X" 7" * (152.4) 22" (177.8) 7" * 6" (177.8) 7" * 7" * (177.8) (177.8) (304.8) (304.8) (177.8) 7" * 12" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/4" GLASS, 1" INSULATING GLASS or 1" IMPACT GLASS MARCH, 2016 FlushlineTM Entrances EC 97911-090 FRAME ADAPTER 11 4 3/8" 1/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. The FlushlineTM Frame Adapter is an economical answer for remodel/retrofit projects where new entrance doors are being installed into existing frames. The FlushlineTM Frame Adapter utilizes polymeric bulb weathering for a resistive weatherseal on three sides of the door. When the frame adapter is used in conjuction with a continuous hinge the need for existing frame tear-out and attempting to align hardware on a new door with an existing frame is eliminated. 1 237430 2 3 1 HEAD 237430 2 HINGE JAMB 3 LOCK JAMB 237431 237430 237430 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 237430 4 CORNER ASSEMBLY kawneer.com ADMA060EN 3/8" 1/8" 1/8" (3.2) ADMA060EN MASONRY OPENING OVERALL FRAME DOOR OPENING 3/32" (2.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FlushlineTM Entrances MARCH, 2016 STANDARD ENTRANCE PACKAGES EC 97911-090 OPTIONAL BOTTOM RAIL WEATHERING 237795 3' (914.4) Sweep 237798 6' (1,828.8) Sweep kawneer.com © Kawneer Company, Inc., 2015 1/8" (3.2) 1/8" (3.2) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/16" (4.3) OVERALL FRAME 3/32" (2.4) 1/2" (12.7) DOOR OPENING MASONRY OPENING 12 SCALE 3" = 1' 0" DIMENSIONS ARE NOMINAL MARCH, 2016 FlushlineTM Entrances EC 97911-090 ENTRANCE OFFERINGS WITHOUT TRANSOM Door Opening Dimension 3' 0" x 7' 0" (914 x 2134) 3' 6" x 7' 0" (1067 x 2134) 6' 0" x 7' 0" (1829 x 2134) Overall Frame Dimension 3' 3-1/2" x 7' 1-3/4" (1003 x 2178) 3' 9-1/2" x 7' 1-3/4" (1156 x 2178) 6' 3-1/2" x 7' 1-3/4" (1918 x 2178) Masonry Opening Dimension 3' 4-1/4" x 7' 2-1/8" (1022 x 2188) 3' 10-1/4" x 7' 2-1/8" (1175 x 2188) 6' 4-1/4" x 7' 2-1/8" (1937 x 2188) WITH TRANSOM Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 1-3/4" (959) to above heights. Masonry Opening Dimension Add 3' 2-1/8" (968) to above heights. WITH TRANSOM PANEL Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 1-3/4" (959) to above heights. Masonry Opening Dimension Add 3' 2-1/8" (968) to above heights. STANDARD SIZES (TRIFABTM VG 451 CENTER FRAMES) WITHOUT TRANSOM Door Opening Dimension 3' 0" x 7' 0" (914 x 2134) 3' 6" x 7' 0" (1067 x 2134) 6' 0" x 7' 0" (1829 x 2134) Overall Frame Dimension 3' 4" x 7' 2" (1016 x 2185) 3' 10" x 7' 2" (1168 x 2185) 6' 4" x 7' 2" (1930 x 2185) Masonry Opening Dimension 3' 4-3/4" x 7' 2-3/8" (1035 x 2194) 3' 10-3/4" x 7' 2-3/8" (1187 x 2194) 6' 4-3/4" x 7' 2-3/8" (1949 x 2194) WITH TRANSOM Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 2" (965) to above heights. Masonry Opening Dimension Add 3' 2-3/8" (975) to above heights. WITH TRANSOM PANEL Door Opening Dimension Unchanged from above. Overall Frame Dimension Add 3' 2" (965) to above heights. Masonry Opening Dimension Add 3' 2-3/8" (975) to above heights. STANDARD SIZES (FLUSHLINE™ FRAME ADAPTER) WITHOUT TRANSOM Door Opening Dimension 3' 0" x 7' 0" (914 x 2134) 3' 6" x 7' 0" (1067 x 2134) 6' 0" x 7' 0" (1829 x 2134) Overall Frame Dimension 3' 0-3/4" x 7' 0-3/8" (933 x 2143) 3' 6-3/4" x 7' 0-3/8" (1086 x 2143) 6' 0-3/4" x 7' 0-3/8" (1848 x 2143) © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD SIZES (TRIFABTM 400 & TRIFABTM VG 450 CENTER FRAMES) kawneer.com ADMA060EN 13 FlushlineTM Entrances MARCH, 2016 EC 97911-090 HINGING OPTIONS GLAZING STOP OPTIONS GLASS THICKNESS Single 3'-6" x 7'-6" (1066.8 x 2286) Pair 7'-0" x 7'-6" (2133.6 x 2286) ± 70 PSF Offset Pivots Butt Hinges Continuous Hinge 1 1" (25.4) Kawneer 1686 Concealed Rod Exit Device (EL option) Single 3'-6" x 7'-6" (1066.8 x 2286) Pair 7'-0" x 7'-6" (2133.6 x 2286) ± 70 PSF Offset Pivots Butt Hinges Continuous Hinge 1 1" (25.4) Corbin Russwin ED5200S Rim Device Single 3'-6" x 7'-6" (1066.8 x 2286) Pair 7'-0" x 7'-6" (2133.6 x 2286) ± 50 PSF (Zone 3 only) Offset Pivots Butt Hinges Continuous Hinge 1 1" (25.4) Schage L9453P Mortise Lock Single 3'-6" x 7'-6" (1066.8 x 2286) Pair 8'-0" x 8'-0" (2438.4 x 2438.4) ± 75 PSF Offset Pivots Butt Hinges Continuous Hinge 1 1" (25.4) HINGING OPTIONS GLAZING STOP OPTIONS GLASS THICKNESS Offset Pivots Butt Hinges 1 1" (25.4) Offset Pivots Butt Hinges 1 1" (25.4) MS 1850 3-Point Lock (Active leaf) Flushbolts (Inactive leaf) MAXIMUM DOOR SIZE Glazing Stop Options: 1 - Structural silicone with 0.090 Kuraray or Eastman PVB inter layer. ENTRANCE HARDWARE OFFERINGS Blast Mitigation Product LOCKING OPTIONS MS 1850 3-Point Lock (Active leaf) Flushbolts (Inactive leaf) Schage L9453P Mortise Lock MAXIMUM DOOR SIZE Single 3'-6" x 6'-6" (1066.8 x 1981.2) Pair 7'-0" x 6'-6" (2133.6 x 1981.2) Single 3'-6" x 6'-6" (1066.8 x 1981.2) MAXIMUM BLAST LOADING Peak Pressure: 4 PSI Impulse: 28 PSI•MSEC Peak Pressure: 4 PSI Impulse: 28 PSI•MSEC Test conditions shown. Other conditions may be supported through calulation. Glazing Stop Options: 1 - Structural silicone with 0.060 Kuraray or Eastman PVB inter layer. ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 MAXIMUM DESIGN PRESSURE LOCKING OPTIONS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. ENTRANCE HARDWARE OFFERINGS Hurricane Resistant Product Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 MARCH, 2016 FlushlineTM Entrances EC 97911-090 ENTRANCE OFFERINGS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD 15 OPTIONAL Doors Flushline™ doors prepared for attachment hardware. Door Sizes Std. Standard sizes shown on page 12. Any size up to 4'-0" x 8'-0" (1219 x 2438). Glass Stops Vision Lite for 1/4" (6.4) or 3/16" (4.0) infill. Vision Lite for 1" (25.4) infill. Vision Lite for 1" (25.4) impact infill. Door Frames TrifabTM 400 - 1-3/4" x 4" (44.5 x 101.6) for single glazing. Any Kawneer framing system suitable for door frames may be selected, but manufactured per order. Trifab VG 450 Center - 1-3/4" x 4-1/2" (44.5 x 114.3) for single glazing. TM TrifabTM VG 451 Center - 2" x 4-1/2" (50.8 x 114.3) for double glazing. Push-Pulls Single Acting: Architects Classic Hardware "CO-9" Pull and "CP-II" Push Bar. Single Acting: Architects Classic Hardware "CO-9" Pull and "CP" Push Bar. Architects Classic Hardware "CO-12" and "CP-II" push bar. Architects Classic Hardware "CO-12" and "CP" push bar. Architects Classic Hardware "CO-9"/"CO-9" Pulls. Architects Classic Hardware "CO-12"/"CO-12" Pulls Recessed Pull Door Closers Single Acting: Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check and with or without adjustable hold-open. Standard concealed overhead closer with single acting offset arm. Single Acting: LCN 4040 surface closer with or without adjustable hold-open. LCN 2010, 2030 or 5010 concealed overhead closers with or without hold-open. LCN 1260 adjustable surface closer. Norton 8100 surface closer with a 50% spring power adjustment (for opening forces of less than 8 pounds). Closer is available with standard back-checks and with or without the hold-open feature. Falcon SC 60 surface closer. © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. International single acting concealed overhead closer. Hinging Single Acting: Kawneer top and bottom offset pivots (or) Kawneer top and bottom 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP) (or) Kawneer continuous gear hinge. Intermediate Pivots/Butts Single Acting: Rixson M-19 or IVES #7215-INT intermediate offset pivot (or) Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP). Power Transfers Single Acting: Rixson M-19 EL or IVES #7215-INT intermediate offset pivot (or) Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with wire transfer (or) EPT (Electric Power Transfer). Power Supply SP-1000X Power Supply: For use with PanelineTM EL exit devices. PS1, PS5-4, and PS5-6 Power Supplies: For use with Kawneer 1686 EL and 1786 EL exit devices only. Locks Active Leaf Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders. Adams-Rite #4510 latch lock. Adams-Rite #1850A-020 short throw deadlock. Adams-Rite #1850A-050 hookbolt lock. Adams-Rite #4015 two-point Lock. Adams-Rite #4085 three-point Lock. Adams-Rite #4089 exit indicator. Kawneer cylinder guard. Kawneer thumbturn (in lieu of cylinder). Schlage L9453P mortise lock. Yale 8860 mortise lock. Yale 5407 knob lock. Corbin Russwin CK4451 knob lock. kawneer.com ADMA060EN FlushlineTM Entrances MARCH, 2016 ENTRANCE OFFERINGS/APPLICATION CRITERIA EC 97911-090 OPTIONAL One pair of Kawneer flush bolts in the inactive leaf of a pair of doors. Thresholds A 1/2" x 4" (12.7 x 101.6) aluminum mill finish threshold. A 1/2" x 6-3/4" (12.7 x 171.5) aluminum mill finish threshold. Weathering Single Acting: Bottom Door Sweep Exit Device Kawneer 1686 Concealed Rod Exit Device with or without a mortised type cylinder. Kawneer 1786 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Pairs of doors require a Kawneer RM-86 removable mullion. PanelineTM exit device is a concealed rod exit device applicable to single or pairs of doors. It features an activating panel contained within the door cross rail. Exit Device Pulls: Architects Classic style "CO-9" Pull with Kawneer 1686 and 1786 exit devices. Architects Classic style "CO9" Pull for PanelineTM and PanelineTM EL exit devices. Kawneer 1686 EL Concealed Rod Exit Device electric modification is available. Kawneer 1786 EL Rim Exit Device electric modification is available. Kawneer 1686 CD Concealed Rod Exit Device available with cylinder dogging. Kawneer 1786 CD Rim Exit Device available with cylinder dogging. Kawneer 1686 Lever Handle is available for the Kawneer 1686 concealed rod exit device. Kawneer 1786 Lever Handle is available for the Kawneer 1786 rim type exit device. Falcon 1690 Concealed Rod Exit Device with or without a mortised type cylinder. Falcon 1790 Rim Exit Device is a rim type exit device with or without a rim type cylinder. Falcon EL 1690 electric modification is also available. Falcon EL 1790 electric modification is also available PanelineTM EL electric modification is also available. Corbin Russwin ED5200S Rim Exit Device is a rim type exit device. Pairs of doors require a removable mullion, WS707/708AKM. Falcon 1990 is a concealed rod exit device with or without a rim type cylinder. Falcon 2090 is a rim type exit device with or without a rim type cylinder. Pairs of doors require a removable aluminum mullion. RM-70 with the Falcon 2090 exit device. Optional Exit Device Pulls: Architects Classic style "CO-12" Pull with Kawneer 1686 and 1786 exit devices. APPLICATION CRITERIA As indicated on page 13, the standard sizes of swing doors are 3'-0" x 7'-0" (914.4 x 2133.6) or 3'-6" x 7'-0" (1067 x 2134) for single doors and 6'-0" x 7'-0" (1828.8 x 2133.6) for pairs of doors. When these sizes are exceeded the following criteria should be administered. 1. Larger doors should not be subject to heavy traffic or strong prevailing wind conditions. 2. Larger doors should use a door closer with a good back check action. 3. When a door exceeds 9'-0" (2743.2) in height, a crossrail or push bar is recommended to reinforce the internal vertical stiles. 4. When an offset hung door exceeds 7'-6" (2286.0) in height, an intermediate butt or offset pivot should be used. 5. Tall doors should be prevented from racking by proper utilization of hardware, including door closers, door holders and door stops. NOTE: SOME OF THESE CRITERIA ARE OF A SUBJECTIVE NATURE, CONTACT YOUR FACTORY REPRESENTATIVE FOR APPLICATION ASSISTANCE. MAXIMUM DOOR HEIGHT FOR PANELINETM EL = 8'-0" ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. (The system is complete with an optional EPDM blade gasket sweep strip applied to the bottom door rail with concealed fasteners). Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. STANDARD Locks Inactive Leaf Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 MARCH, 2016 FlushlineTM Entrances EC 97911-090 PUSH-PULL HARDWARE 17 REFER TO HARDWARE SECTION FOR COMPLETE HARDWARE INFORMATION. ARCHITECTS CLASSIC (PUSH PULL SETS) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR AS STANDARD CP-II/CP-II CO-9/CO-9 CO-12/CO-12 CP/CP CO-9/CP-II CO-12 /CP-II CO-9/CP CO-12/CP RECESSED PULL ARCHITECTS CLASSIC (COMPONENTS) STYLE CO-12 PULL STYLE CO-9 PULL EXIT DEVICES STYLE CP PUSH BAR STYLE CP-II PUSH BAR EXIT DEVICES AND PULLS 9-5/16" OVERALL W/ STOPS (236.5) © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. KAWNEER PANELINETM / PANELINETM EL INTERIOR VIEW STYLE "CO-9" PULL STYLE"CO9" PULL ON EXTERIOR OF DOOR STYLE "CO-12" PULL RIM LATCH Falcon 2090 CONCEALED ROD Falcon 1990 CONCEALED ROD Falcon 1690 Falcon EL 1690 RIM LATCH Falcon 1790 Falcon EL 1790 RIM LATCH Corbin Russwin ED5200S CONCEALED ROD Kawneer 1686 Kawneer 1686 EL Kawneer 1686 CD RIM LATCH Kawneer 1786 Kawneer 1786 EL Kawneer 1786 CD LEVER HANDLE Kawneer 1686 Kawneer 1786 eer Kawn EXTERIOR VIEW OF FLUSHLINE™ DOOR "CO9" PULL AND OPTIONAL CYLINDER GUARD SHOWN. SEE PAGE 17 AND 18 FOR COMPLETE PANELINETM INFORMATION kawneer.com ADMA060EN 18 FlushlineTM Entrances MARCH, 2016 PANELINETM EXIT DEVICE EC 97911-090 The PanelineTM concealed rod exit device for Flushline™ doors will accommodate variations in stile width and door width as shown in the following illustrations. Sidelites adjacent to PanelineTM equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the PanelineTM cross rail. The Optional PanelineTM EL device is designed for electrified access control and is compatible with most key pad and card reader systems. PanelineTM uses mortise cylinder in lieu of the normal rim-type. Dummy PanelineTM units are not for use with any type of lock. 1 3/4" (44.4) 3/16" (4.7) 1 1/8" (28.6) INTERIOR ELEVATIONS NOTE: Sidelites must be stop glazed above and below rail. 2 8 1/4" (209.5) 2 3* SIDELITE CROSSRAIL CROSSRAIL WITH FIXED PANEL 3* SEE NOTE SIDELITE 36-1/8" (917.6) TO BOTTOM OF DOOR *VESTIBULE DOOR (Without Exit Device or Lock) CROSSRAIL WITH EXIT DEVICE AND CO9 PULL HANDLE INTERIOR VIEW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ACTIVE DOOR PANELINETM EL COMPONENTS PIVOT STILE TRIM FILLER WIDTH VARIES WITH DOOR WIDTH PUSH DOGGING LOCK (TYPICAL) 6-9/32" (159.5) DOOR OPENING WIDTH 4'-0" (1219.2) MAX. - 3'-0" (914.4) MIN. 3'-0" (914.4) ADA MIN. POWER TRANSFER INTERMEDIATE BUTT HINGE POWER TRANSFER INTERMEDIATE OFFSET PIVOT EXTERIOR VIEW ELECTRIC POWER TRANSFER (EPT) ADMA060EN SP-1000X POWER SUPPLY kawneer.com © Kawneer Company, Inc., 2015 1 1 PUSH 8" (203.2) PUSH 7 1/8" (180.9) SEE NOTE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. See Hardware Section for complete description of PanelineTM hardware, including finish of units. MARCH, 2016 FlushlineTM Entrances EC 97911-090 PANELINETM EXIT DEVICE 19 Sidelites adjacent to PanelineTM equipped doors not requiring exit devices may be fitted with fixed panels as detailed below to match the general appearance of the PanelineTM cross rail. See Hardware Section for complete description of PanelineTM hardware, including finish of units. 1 3/4" (44.4) 3/16" (4.7) 1 1/8" (28.6) INTERIOR ELEVATION NOTE: Sidelites must be stop glazed above and below rail. 1 PUSH 1 OR 3* 8 1/4" (209.5) PUSH 8" (203.2) SEE NOTE 7 1/8" (180.9) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PanelineTM uses mortise cylinder in lieu of the normal rim-type. Dummy PanelineTM units should not use any type of lock. 2 3* SIDELITE CROSSRAIL CROSSRAIL WITH FIXED PANEL 2 1 OR 3* SEE NOTE INACTIVE DOOR ACTIVE DOOR 36-1/8" (917.6) TO BOTTOM OF DOOR SIDELITE * ALTERNATE CROSSRAIL FOR VESTIBULE DOORS (Without Exit Device or Lock) CROSSRAIL WITH EXIT DEVICE AND CO9 PULL HANDLE PIVOT STILE TRIM FILLER WIDTH VARIES WITH DOOR WIDTH PUSH PUSH DOGGING LOCK (TYPICAL) © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. INTERIOR VIEW DOOR OPENING WIDTH 8'-0" (2438.4) MAX. - 6'-0" (1828.8) MIN. 6'-0" (1828.8) ADA MIN. STYLE"CO9" PULL ON EXTERIOR OF DOOR EXTERIOR VIEW WITH "CO9" PULL AND STANDARD CYLINDER GUARD SHOWN kawneer.com ADMA060EN FlushlineTM Entrances MARCH, 2016 THERMAL CHARTS EC 97911-090 Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) "X" (F.H.) 32" (812.8) (DLO) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7" (177.8) 22" (558.8) (DLO) 7' 1-3/4" (2178.1) 3' 3-1/2" (1003.3) (F.W.) Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F Total Daylight Opening = 22" x 32" = 4.89 ft2 Total Projected Area = 3' 3-1/2" x 7' 1-3/4" = 23.52 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (4.89 ÷ 23.52)100 = 21% System U-factor vs Percent of Glass Area 0.90 COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.85 0.40 (2.27) 0.36 (2.05) 0.34 (1.93) 0.30 (1.71) O E IGN PL S M E A D EX FOR N 0.32 (1.82) 0.28 (1.59) 0.80 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) Btu hr • ft2 • °F System U-factor T 0.26 (1.48) 0.75 0.74 0.70 42 37 32 27 22 Percent of Glass Area 17 12 0.65 Based on 21% glass and center of glass (COG) U-factor of 0.28 System U-factor is equal to 0.74 Btu/hr • ft2 • °F ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.38 (2.16) 21% 20 MARCH, 2016 FlushlineTM Entrances EC 97911-090 THERMAL CHARTS FLUSHLINETM DOOR WITH ALUMINUM SKIN System U-factor vs Percent of Glass Area Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.90 COG U-factor 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.85 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.80 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.02) 0.16 (0.91) 0.75 0.12 (0.68) 0.10 (0.57) 0.70 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.14 (0.80) 42 37 32 27 22 17 12 0.65 Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMA060EN System U-factor (BTU/hr·ft2·oF) 0.34 (1.93) 21 FlushlineTM Entrances MARCH, 2016 THERMAL CHARTS EC 97911-090 FLUSHLINETM DOOR WITH ALUMINUM SKIN COG SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 0.35 0.75 0.70 0.65 0.55 0.25 0.50 0.45 0.20 0.40 0.35 0.30 0.15 0.25 0.20 0.10 0.15 System SHGC 0.30 0.60 0.10 0.05 0.05 42 37 32 27 22 17 12 0.00 COG VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System Visible Transmittance (VT) vs Percent of Vision Area 0.35 0.75 0.30 0.70 0.65 0.60 0.25 0.55 0.50 0.20 0.45 0.40 0.15 0.35 0.30 0.25 0.10 0.20 0.15 0.05 0.10 0.05 42 37 32 27 22 17 12 0.00 Vision Area / Total Area (%) ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Vision Area / Total Area (%) System VT 22 MARCH, 2016 FlushlineTM Entrances EC 97911-090 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Single Door with Aluminum Panel and 1/4 Vision Lite Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.74 0.46 0.74 0.44 0.73 0.42 0.73 0.40 0.73 0.38 0.73 0.36 0.73 0.34 0.72 0.32 0.72 0.30 0.72 0.28 0.72 0.26 0.71 0.24 0.71 0.22 0.71 0.20 0.71 0.18 0.70 0.16 0.70 0.14 0.70 0.12 0.70 0.10 0.69 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 23 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.12 0.75 0.09 0.70 0.12 0.70 0.08 0.65 0.11 0.65 0.08 0.60 0.10 0.60 0.07 0.55 0.10 0.55 0.07 0.50 0.09 0.50 0.06 0.45 0.09 0.45 0.05 0.40 0.08 0.40 0.05 0.35 0.07 0.35 0.04 0.30 0.07 0.30 0.04 0.25 0.06 0.25 0.03 0.20 0.05 0.20 0.02 0.15 0.05 0.15 0.02 0.10 0.04 0.10 0.01 0.05 0.04 0.05 0.01 ADMA060EN FlushlineTM Entrances MARCH, 2016 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-090 Overall U-Factor 4 0.48 0.79 0.46 0.79 0.44 0.78 0.42 0.78 0.40 0.77 0.38 0.77 0.36 0.77 0.34 0.76 0.32 0.76 0.30 0.75 0.28 0.75 0.26 0.74 0.24 0.74 0.22 0.74 0.20 0.73 0.18 0.72 0.16 0.72 0.14 0.72 0.12 0.71 0.10 0.71 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.21 0.75 0.18 0.70 0.20 0.70 0.17 0.65 0.18 0.65 0.15 0.60 0.17 0.60 0.14 0.55 0.16 0.55 0.13 0.50 0.15 0.50 0.12 0.45 0.14 0.45 0.11 0.40 0.12 0.40 0.09 0.35 0.11 0.35 0.08 0.30 0.10 0.30 0.07 0.25 0.09 0.25 0.06 0.20 0.08 0.20 0.05 0.15 0.07 0.15 0.04 0.10 0.05 0.10 0.02 0.05 0.04 0.05 0.01 ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Single Door with Aluminum Panel and 1/2 Vision Lite Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 MARCH, 2016 FlushlineTM Entrances EC 97911-090 THERMAL CHARTS FLUSHLINETM DOOR WITH FRP SKIN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-factor vs Percent of Glass Area 0.85 COG U-factor 0.48 (2.73) 0.46 (2.61) 0.80 0.44 (2.50) 0.42 (2.39) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.75 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.70 0.18 (1.02) 0.16 (0.91) 0.14 (0.80) 0.12 (0.68) 0.10 (0.57) 0.65 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.20 (1.14) 42 37 32 27 22 17 12 0.60 Percent of Glass = Vision Area/Total Area (Total Daylight Opening / Projected Area) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMA060EN System U-factor (BTU/hr·ft2·oF) 0.40 (2.27) 25 FlushlineTM Entrances MARCH, 2016 THERMAL CHARTS EC 97911-090 FLUSHLINETM DOOR WITH FRP SKIN COG SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 0.35 0.75 0.70 0.65 0.30 0.55 0.25 0.50 0.45 0.20 0.40 0.35 0.30 0.15 0.25 0.20 0.10 0.15 System SHGC 0.60 0.10 0.05 0.05 42 37 32 27 22 17 12 0.00 COG VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System Visible Transmittance (VT) vs Percent of Vision Area 0.35 0.75 0.30 0.70 0.65 0.60 0.25 0.55 0.50 0.20 0.45 0.40 0.15 0.35 0.30 0.25 0.10 0.20 0.15 0.05 0.10 0.05 42 37 32 27 22 17 12 0.00 Vision Area / Total Area (%) ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Vision Area / Total Area (%) System VT 26 MARCH, 2016 FlushlineTM Entrances EC 97911-090 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Single Door with FRP Panel and 1/4 Vision Lite Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.67 0.46 0.67 0.44 0.66 0.42 0.66 0.40 0.66 0.38 0.66 0.36 0.66 0.34 0.65 0.32 0.65 0.30 0.65 0.28 0.65 0.26 0.64 0.24 0.64 0.22 0.64 0.20 0.64 0.18 0.63 0.16 0.63 0.14 0.63 0.12 0.63 0.10 0.62 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 27 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.12 0.75 0.09 0.70 0.11 0.70 0.08 0.65 0.11 0.65 0.08 0.60 0.10 0.60 0.07 0.55 0.09 0.55 0.07 0.50 0.09 0.50 0.06 0.45 0.08 0.45 0.05 0.40 0.08 0.40 0.05 0.35 0.07 0.35 0.04 0.30 0.06 0.30 0.04 0.25 0.06 0.25 0.03 0.20 0.05 0.20 0.02 0.15 0.05 0.15 0.02 0.10 0.04 0.10 0.01 0.05 0.03 0.05 0.01 ADMA060EN FlushlineTM Entrances MARCH, 2016 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-090 Overall U-Factor 4 0.48 0.72 0.46 0.72 0.44 0.71 0.42 0.71 0.40 0.70 0.38 0.70 0.36 0.69 0.34 0.69 0.32 0.69 0.30 0.68 0.28 0.68 0.26 0.67 0.24 0.67 0.22 0.66 0.20 0.66 0.18 0.65 0.16 0.65 0.14 0.64 0.12 0.64 0.10 0.64 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.20 0.75 0.18 0.70 0.19 0.70 0.17 0.65 0.18 0.65 0.15 0.60 0.17 0.60 0.14 0.55 0.16 0.55 0.13 0.50 0.15 0.50 0.12 0.45 0.13 0.45 0.11 0.40 0.12 0.40 0.09 0.35 0.11 0.35 0.08 0.30 0.10 0.30 0.07 0.25 0.09 0.25 0.06 0.20 0.07 0.20 0.05 0.15 0.06 0.15 0.04 0.10 0.05 0.10 0.02 0.05 0.04 0.05 0.01 ADMA060EN kawneer.com © Kawneer Company, Inc., 2015 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Single Door with FRP Panel and 1/2 Vision Lite Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28