G3VM-@CR@/@FR@ MOS FET Relays DIP 8-pin, High-Current and Low-ON-resistance Type DIP The highest class load current of MOS FET Relays realized with DIP8 package • Contact form: 1a (SPST-NO) • Load voltage: 60 V, 400 V, or 600 V G3VM-@CR@/@FR@ • 60-V Relay: Continuous load current of 5 A (10 A) max. * • 400-V Relay: Continuous load current of 0.4 A (0.8 A) max. * • 600-V Relay: Continuous load current of 0.6 A (1.2 A) max. * * Values in parentheses are for connection C. Note: The actual product is marked differently from the image shown here. RoHS Compliant ■Application Examples • Communication equipment • Test & Measurement equipment • Industrial equipment • Power circuit ■Package • Security equipment ■Model Number Legend (Unit : mm, Average) G 3 V M -@ @ @ @ @ DIP 8-pin PCB Terminals 1 2 3 4 9.66 1. Load Voltage 6 : 60 V 40 : 400 V 60 : 600 V 3.65 6.4 Surface-mounting Terminals 5 2. Contact form 1 : 1a (SPST-NO) 4. Additional functions R: Low ON resistance 9.66 3.65 3. Package C : DIP 8-pin with PCB terminals F : DIP 8-pin with surface-mounting terminals 5. Other informations When specifications overlap, serial code is added in the recorded order. 6.4 Note: The actual product is marked differently from the image shown here. ■Ordering Information Package Contact form DIP8 1a (SPST-NO) Stick packaging Load voltage Continuous load current Model (peak value) (peak value) * Surface-mounting * PCB Terminals Terminals 60 V 5A G3VM-61CR1 G3VM-61FR1 400 V 0.4 A G3VM-401CR G3VM-401FR 600 V 0.6 A G3VM-601CR G3VM-601FR Tape packaging Minimum package quantity Surface-mounting Terminals 50 pcs. G3VM-401FR(TR05) Minimum package quantity G3VM-61FR1(TR05) * The AC peak and DC value are given for the load voltage and continuous load current. Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR05)” to the end of the model number. 1 Model G3VM-601FR(TR05) 500 pcs. G3VM-@CR@/@FR@ MOS FET Relays ■Absolute Maximum Ratings (Ta = 25°C) Input Item Symbol G3VM-401CR G3VM-401FR G3VM-601CR G3VM-601FR Unit LED forward current IF 30 Repetitive peak LED forward current IFP 1 A ΔIF/°C -0.3 mA/°C VR 5 V LED forward current reduction rate LED reverse voltage Connection temperature TJ VOFF Continuous load current mA 125 600 5 0.4 0.6 5 0.4 0.6 Connection C 10 0.8 1.2 Connection A -50 -4 -6 -50 -4 -6 -100 -8 -12 1.2 1.8 IO ΔIO/°C ON current reduction rate Connection B Connection C Pulse ON current lop Connection temperature TJ 15 V A mA/°C A 125 °C Dielectric strength between I/O (See note 1.) VI-O 2,500 Vrms Ambient operating temperature Ta -40 to +85 °C Tstg -55 to +125 °C − 260 °C Ambient storage temperature Soldering temperature Ta ≥ 25°C Connection A: AC peak/DC Connection B and C: DC G3VM-@CR@/@FR@ 400 Connection B 100 μs pulses, 100 pps °C 60 Connection A Measurement conditions DIP Load voltage (AC peak/DC) Output G3VM-61CR1 G3VM-61FR1 Ta ≥ 25°C t=100 ms, Duty=1/10 AC for 1 min With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A Connection B Connection C 1 8 2 7 3 6 4 5 1 8 2 7 3 6 4 5 1 8 2 7 3 6 4 5 LOAD AC or DC LOAD DC LOAD DC 2 G3VM-@CR@/@FR@ MOS FET Relays ■Electrical Characteristics (Ta = 25°C) Item DIP Input LED forward voltage VF Minimum 1.5 Typical 1.64 Maximum 1.8 V Measurement conditions IF=10 mA G3VM-@CR@/@FR@ Reverse current IR Maximum 10 μA VR=5 V Capacitance between terminals CT Typical 70 pF V=0, f=1MHz Trigger LED forward current IFT mA G3VM-61CR1/FR1 : IO=1 A G3VM-401CR/FR : IO=0.4 A G3VM-601CR/FR : IO=0.6 A Release LED forward current IFC mA G3VM-61CR1/FR1 : IOFF=1 μA G3VM-401CR/FR : IOFF=10 μA G3VM-601CR/FR : IOFF=1 μA Connection A Output G3VM-61CR1 G3VM-401CR G3VM-601CR Unit G3VM-61FR1 G3VM-401FR G3VM-601FR Symbol Maximum resistance with output ON RON Connection B Connection C Current leakage when the relay is open ILEAK Typical 0.28 0.2 0.23 Maximum 5 1 5 Minimum 0.01 Typical 0.19 0.17 Typical 0.022 3 1.3 Maximum 0.05 5 2 Maximum 0.025 2.5 1 Maximum 0.013 1.3 0.5 Typical 0.01 0.001 0.05 Maximum 10 1 10 850 410 4,300 Capacitance between terminals COFF Typical Capacitance between I/O terminals CI-O Typical 0.8 Insulation resistance between I/O terminals RI-O Minimum 1,000 Typical 108 Turn-ON time tON Turn-OFF time tOFF Typical 2.5 0.22 Maximum 5 1 3 Typical 0.1 0.08 0.07 Maximum G3VM-61CR1/FR1 : IO=1 A, IF=5 mA, t < 1 s G3VM-401CR/FR : IO=0.4 A, IF=2 mA, t < 1 s G3VM-601CR/FR : IO=0.6 A, IF=5 mA, t < 1 s Ω G3VM-61CR1/FR1 : IO=1A, IF=2 mA, t < 1 s G3VM-401CR/FR : IO=0.4A, IF=2 mA, t < 1 s G3VM-601CR/FR : IO=0.6A, IF=2 mA, t < 1 s G3VM-61CR1/FR1 : IO=1 A, IF=2 mA, t < 1 s G3VM-401CR/FR : IO=0.8 A, IF=2 mA, t < 1 s G3VM-601CR/FR : IO=1.2 A, IF=2 mA, t < 1 s μA VOFF=Load Voltage Ratings pF V=0, f=1 MHz pF f=1 MHz, VS=0 V MΩ VI-O=500 VDC, ROH=60% ms IF =5 mA, RL =200 Ω, VDD=20 V (See note 2.) 0.8 1 Note: 2. Turn-ON and Turn-OFF Times IF 2 5 3 8 RL IF VDD VOUT VOUT 10% 90% t ON t OFF ■Recommended Operating Conditions For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item G3VM-61CR1 G3VM-61FR1 G3VM-401CR G3VM-401FR G3VM-601CR G3VM-601FR Unit Maximum 48 320 480 V Typical 5 2 5 Symbol Load voltage (AC peak/DC) VDD Operating LED forward current IF Continuous load current (AC peak/DC) IO Ambient operating temperature Ta Maximum Maximum Item Minimum 7.0 Clearance distances 7.0 Internal isolation thickness 0.4 3 5 0.4 Minimum -40 Maximum 85 ■Spacing and Insulation Creepage distances 25 Unit mm 0.6 mA A °C G3VM-@CR@/@FR@ MOS FET Relays ■Engineering Data 35 30 25 20 (Maximum value) Connection C 10 8 6 Connection A, B 4 IO - Ta ● LED forward current vs. LED forward voltage IF - VF 100 LED forward current IF (mA) 0 -20 20 40 60 80 100 Ambient temperature Ta (°C) 0 20 ● Continuous load current vs. On-state voltage G3VM-61CR1/61FR1 (Average value) Ta=25°C 10 1 IO - VON (Average value) 6 Ta=25°C, IF=5mA, t<1s, Connection A 4 2 0 -2 0 20 40 60 80 100 Ambient temperature Ta (°C) 0.8 0.6 Ta=25°C, IF=5mA, t<1s, Connection A 0.4 G3VM-601CR/601FR (Average value) 0.2 0 G3VM-401CR/401FR -0.2 -0.6 -6 -0.2 1.2 1.4 1.6 1.8 LED forward voltage VF (V) -0.1 -0.8 -1.5 0 0.1 0.2 On-state voltage VON (V) -1 -0.5 1 1.5 G3VM-401CR/401FR/601CR/601FR (Average value) IO=1A, IF=5mA, t<1s, Connection A 0.02 0.015 RON - Ta (Average value) 5 G3VM-401CR/401FR : IO=0.4A, IF=2mA, t<1s, Connection A G3VM-601CR/601FR : IO=0.6A, IF=5mA, t<1s, Connection A 4 G3VM-401CR/401FR 3 2 G3VM-601CR/601FR 0.01 1 0.005 IFT - Ta 0.7 0 -40 20 40 60 80 100 Ambient temperature Ta (°C) -20 0 20 40 60 80 100 Ambient temperature Ta (°C) (Average value) G3VM-61CR1/61FR1 : IO=1A G3VM-401CR/401FR : IO=0.4A G3VM-601CR/601FR : IO=0.6A 0.6 0.5 G3VM-601CR/601FR 0.4 G3VM-61CR1/61FR1 0.3 0.2 G3VM-401CR/401FR 0.1 0 0.5 ● Trigger LED forward current vs. Ambient temperature 0.03 -20 0 On-state voltage VON (V) Trigger LED forward current IFT (mA) 1 On-state resistance RON (Ω) 0.8 RON - Ta On-state resistance RON (Ω) 0.6 -0.4 ● On-state resistance vs. Ambient temperature G3VM-61CR1/61FR1 0 -40 G3VM-401CR/401FR: Connection C IO - VON -4 0.025 0.8 G3VM-601CR/601FR: Connection A, B G3VM-401CR/401FR/601CR/601FR 0.1 0.01 0.6 1 0 -20 40 60 80 100 Ambient temperature Ta (°C) Continuous load current IO (A) 0 Continuous load current IO (A) -20 G3VM-601CR/601FR: Connection C 1.2 G3VM-401CR/401FR: 0.2 Connection A, B 2 0 -40 (Maximum value) 0.4 10 5 1.4 G3VM-@CR@/@FR@ 15 12 G3VM-401CR/401FR/601CR/601FR Continuous load current IO (A) (Maximum value) IO - Ta DIP LED forward current IF (mA) IF - Ta 40 ● Continuous load current vs. Ambient temperature G3VM-61CR1/61FR1 Continuous load current IO (A) ● LED forward current vs. Ambient temperature 0 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ● Turn ON, Turn OFF time vs. LED forward current G3VM-61CR1/61FR1 G3VM-401CR/401FR/601CR/601FR (Average value) Ta=25°C VDD=20V RL=200Ω 1 tON 0.1 tON, tOFF - IF Turn ON, Turn OFF time (ms) Turn ON, Turn OFF time (ms) tON, tOFF - IF 10 10 Ta=25°C VDD=20V RL=200Ω G3VM-601CR/601FR 1 0.1 tON G3VM-401CR /401FR tOFF tOFF G3VM-601CR/601FR 0.01 1 10 100 LED forward current (mA) (Average value) 0.01 1 tON 10 100 LED forward current (mA) 4 G3VM-@CR@/@FR@ MOS FET Relays ■Engineering Data ● Turn ON, Turn OFF time vs. Ambient temperature G3VM-61CR1/61FR1 10 G3VM-401CR/401FR/601CR/601FR (Average value) VDD=20V, RL=200Ω, IF=5mA tON 1 0.01 -40 tOFF -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ● Current leakage vs.Ambient temperature Current Leakage ILEAK (μA) G3VM-@CR@/@FR@ 0.1 tON, tOFF - Ta Turn ON, Turn OFF time tON, tOFF (ms) DIP Turn ON, Turn OFF time tON, tOFF (ms) tON, tOFF - Ta ILEAK - Ta (Average value) 1 VOFF=Load Voltage Ratings 0.1 G3VM-601CR/601FR G3VM-61CR1/61FR1 0.01 0.001 G3VM-401CR/401FR 0.0001 -40 5 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 10 (Average value) VDD=20V, RL=200Ω, IF=5mA G3VM-601CR/601FR 1 tON tON G3VM-401CR/401FR 0.1 G3VM-601CR/601FR 0.01 -40 -20 0 tOFF tOFF 20 40 60 80 100 Ambient temperature Ta (°C) G3VM-@CR@/@FR@ MOS FET Relays ■Appearance / Terminal Arrangement / Internal Connections ●Appearance ●Terminal Arrangement/Internal Connections (Top View) DIP (Dual Inline Package) DIP 8-pin 8 7 6 5 1 2 3 4 Mold pin mark (See note 3.) OMRON logo Model name (See note 2.) 932 DIP 61CR1 Pin 1 mark LOT.NO. G3VM-@CR@/@FR@ Note: 1. The actual product is marked differently from the image shown here. Note: 2. “G3VM” does not appear in the model number on the Relay. Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■Dimensions (Unit: mm) DIP 8-pin Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) PCB Terminals Weight: 0.54 g Weight: 0.54 g 2.54 Eight, 0.8-dia. holes (0.61) 2.54 9.66±0.25 9.66±0.25 (0.61) (1.52) (1.52) 6.4±0.25 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 0.8±0.25 (Recommended Value, Top View) 7.62±0.25 3.65+0.15 -0.25 2.54 0.25+0.1 -0.05 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 3.65+0.15 -0.25 1.2±0.15 7.85 to 8.80 2.54±0.25 4.0+0.25 -0.2 1.0 min. 8.3 to 8.8 1.0 min. 10.0 max. 1.3 1.5 Note: The actual product is marked differently from the image shown here. ■Approved Standards UL recognized Model Approved Standards Contact form File No. G3VM-61CR1 G3VM-61FR1 G3VM-401CR G3VM-401FR Applying for UL recognition G3VM-601CR G3VM-601FR ■Safety Precautions • Refer to the Common Precautions for All MOS FET Relays for precautions that apply to all MOS FET Relays. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K285-E1-01 0416(0416)(O) 6