Datasheet

G3VM-@CR@/@FR@
MOS FET Relays DIP 8-pin, High-Current and Low-ON-resistance Type
DIP
The highest class load current of
MOS FET Relays realized with
DIP8 package
• Contact form: 1a (SPST-NO)
• Load voltage: 60 V, 400 V, or 600 V
G3VM-@CR@/@FR@
• 60-V Relay: Continuous load current of 5 A (10 A) max. *
• 400-V Relay: Continuous load current of 0.4 A (0.8 A) max. *
• 600-V Relay: Continuous load current of 0.6 A (1.2 A) max. *
* Values in parentheses are for connection C.
Note: The actual product is marked differently from the
image shown here.
RoHS Compliant
■Application Examples
• Communication equipment
• Test & Measurement equipment
• Industrial equipment
• Power circuit
■Package
• Security equipment
■Model Number Legend
(Unit : mm, Average)
G 3 V M -@ @ @ @ @
DIP 8-pin
PCB Terminals
1 2 3 4
9.66
1. Load Voltage
6 : 60 V
40 : 400 V
60 : 600 V
3.65
6.4
Surface-mounting Terminals
5
2. Contact form
1 : 1a (SPST-NO)
4. Additional functions
R: Low ON resistance
9.66
3.65
3. Package
C : DIP 8-pin with PCB terminals
F : DIP 8-pin with surface-mounting
terminals
5. Other informations
When specifications overlap, serial code is
added in the recorded order.
6.4
Note: The actual product is marked differently
from the image shown here.
■Ordering Information
Package
Contact
form
DIP8
1a
(SPST-NO)
Stick packaging
Load voltage
Continuous load current
Model
(peak value)
(peak value) *
Surface-mounting
*
PCB Terminals
Terminals
60 V
5A
G3VM-61CR1
G3VM-61FR1
400 V
0.4 A
G3VM-401CR
G3VM-401FR
600 V
0.6 A
G3VM-601CR
G3VM-601FR
Tape packaging
Minimum
package
quantity
Surface-mounting
Terminals
50 pcs.
G3VM-401FR(TR05)
Minimum
package
quantity
G3VM-61FR1(TR05)
* The AC peak and DC value are given for the load voltage and continuous load current.
Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR05)” to the end of the model number.
1
Model
G3VM-601FR(TR05)
500 pcs.
G3VM-@CR@/@FR@
MOS FET Relays
■Absolute Maximum Ratings (Ta = 25°C)
Input
Item
Symbol
G3VM-401CR
G3VM-401FR
G3VM-601CR
G3VM-601FR
Unit
LED forward current
IF
30
Repetitive peak LED forward current
IFP
1
A
ΔIF/°C
-0.3
mA/°C
VR
5
V
LED forward current reduction rate
LED reverse voltage
Connection temperature
TJ
VOFF
Continuous load current
mA
125
600
5
0.4
0.6
5
0.4
0.6
Connection C
10
0.8
1.2
Connection A
-50
-4
-6
-50
-4
-6
-100
-8
-12
1.2
1.8
IO
ΔIO/°C
ON current reduction rate Connection B
Connection C
Pulse ON current
lop
Connection temperature
TJ
15
V
A
mA/°C
A
125
°C
Dielectric strength between I/O (See note 1.)
VI-O
2,500
Vrms
Ambient operating temperature
Ta
-40 to +85
°C
Tstg
-55 to +125
°C
−
260
°C
Ambient storage temperature
Soldering temperature
Ta ≥ 25°C
Connection A:
AC peak/DC
Connection B and C: DC
G3VM-@CR@/@FR@
400
Connection B
100 μs pulses, 100 pps
°C
60
Connection A
Measurement conditions
DIP
Load voltage (AC peak/DC)
Output
G3VM-61CR1
G3VM-61FR1
Ta ≥ 25°C
t=100 ms, Duty=1/10
AC for 1 min
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on
the light-receiving side.
Connection Diagram
Connection A
Connection B
Connection C
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
LOAD
AC or DC
LOAD
DC
LOAD
DC
2
G3VM-@CR@/@FR@
MOS FET Relays
■Electrical Characteristics (Ta = 25°C)
Item
DIP
Input
LED forward voltage
VF
Minimum
1.5
Typical
1.64
Maximum
1.8
V
Measurement conditions
IF=10 mA
G3VM-@CR@/@FR@
Reverse current
IR
Maximum
10
μA
VR=5 V
Capacitance between terminals
CT
Typical
70
pF
V=0, f=1MHz
Trigger LED forward current
IFT
mA
G3VM-61CR1/FR1 : IO=1 A
G3VM-401CR/FR : IO=0.4 A
G3VM-601CR/FR : IO=0.6 A
Release LED forward current
IFC
mA
G3VM-61CR1/FR1 : IOFF=1 μA
G3VM-401CR/FR : IOFF=10 μA
G3VM-601CR/FR : IOFF=1 μA
Connection A
Output
G3VM-61CR1 G3VM-401CR G3VM-601CR
Unit
G3VM-61FR1 G3VM-401FR G3VM-601FR
Symbol
Maximum
resistance with
output ON
RON
Connection B
Connection C
Current leakage when the relay is open
ILEAK
Typical
0.28
0.2
0.23
Maximum
5
1
5
Minimum
0.01
Typical
0.19
0.17
Typical
0.022
3
1.3
Maximum
0.05
5
2
Maximum
0.025
2.5
1
Maximum
0.013
1.3
0.5
Typical
0.01
0.001
0.05
Maximum
10
1
10
850
410
4,300
Capacitance between terminals
COFF
Typical
Capacitance between I/O terminals
CI-O
Typical
0.8
Insulation resistance between I/O
terminals
RI-O
Minimum
1,000
Typical
108
Turn-ON time
tON
Turn-OFF time
tOFF
Typical
2.5
0.22
Maximum
5
1
3
Typical
0.1
0.08
0.07
Maximum
G3VM-61CR1/FR1 : IO=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : IO=0.4 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=0.6 A, IF=5 mA, t < 1 s
Ω
G3VM-61CR1/FR1 : IO=1A, IF=2 mA, t < 1 s
G3VM-401CR/FR : IO=0.4A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=0.6A, IF=2 mA, t < 1 s
G3VM-61CR1/FR1 : IO=1 A, IF=2 mA, t < 1 s
G3VM-401CR/FR : IO=0.8 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=1.2 A, IF=2 mA, t < 1 s
μA
VOFF=Load Voltage Ratings
pF
V=0, f=1 MHz
pF
f=1 MHz, VS=0 V
MΩ
VI-O=500 VDC, ROH=60%
ms
IF =5 mA, RL =200 Ω, VDD=20 V (See note 2.)
0.8
1
Note: 2. Turn-ON and Turn-OFF Times
IF
2
5
3
8
RL
IF
VDD
VOUT
VOUT
10%
90%
t ON
t OFF
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Item
G3VM-61CR1
G3VM-61FR1
G3VM-401CR
G3VM-401FR
G3VM-601CR
G3VM-601FR
Unit
Maximum
48
320
480
V
Typical
5
2
5
Symbol
Load voltage (AC peak/DC)
VDD
Operating LED forward current
IF
Continuous load current (AC peak/DC)
IO
Ambient operating temperature
Ta
Maximum
Maximum
Item
Minimum
7.0
Clearance distances
7.0
Internal isolation thickness
0.4
3
5
0.4
Minimum
-40
Maximum
85
■Spacing and Insulation
Creepage distances
25
Unit
mm
0.6
mA
A
°C
G3VM-@CR@/@FR@
MOS FET Relays
■Engineering Data
35
30
25
20
(Maximum value)
Connection C
10
8
6
Connection A, B
4
IO - Ta
● LED forward current vs.
LED forward voltage
IF - VF
100
LED forward current IF (mA)
0
-20
20
40
60
80 100
Ambient temperature Ta (°C)
0
20
● Continuous load current vs.
On-state voltage
G3VM-61CR1/61FR1
(Average value)
Ta=25°C
10
1
IO - VON
(Average value)
6
Ta=25°C, IF=5mA,
t<1s, Connection A
4
2
0
-2
0
20
40
60
80
100
Ambient temperature Ta (°C)
0.8
0.6
Ta=25°C, IF=5mA,
t<1s, Connection A
0.4
G3VM-601CR/601FR
(Average value)
0.2
0
G3VM-401CR/401FR
-0.2
-0.6
-6
-0.2
1.2
1.4
1.6
1.8
LED forward voltage VF (V)
-0.1
-0.8
-1.5
0
0.1
0.2
On-state voltage VON (V)
-1
-0.5
1
1.5
G3VM-401CR/401FR/601CR/601FR
(Average value)
IO=1A, IF=5mA,
t<1s, Connection A
0.02
0.015
RON - Ta
(Average value)
5
G3VM-401CR/401FR : IO=0.4A, IF=2mA, t<1s, Connection A
G3VM-601CR/601FR : IO=0.6A, IF=5mA, t<1s, Connection A
4
G3VM-401CR/401FR
3
2
G3VM-601CR/601FR
0.01
1
0.005
IFT - Ta
0.7
0
-40
20
40
60
80 100
Ambient temperature Ta (°C)
-20
0
20
40
60
80 100
Ambient temperature Ta (°C)
(Average value)
G3VM-61CR1/61FR1 : IO=1A
G3VM-401CR/401FR : IO=0.4A
G3VM-601CR/601FR : IO=0.6A
0.6
0.5
G3VM-601CR/601FR
0.4
G3VM-61CR1/61FR1
0.3
0.2
G3VM-401CR/401FR
0.1
0
0.5
● Trigger LED forward current vs.
Ambient temperature
0.03
-20
0
On-state voltage VON (V)
Trigger LED forward current IFT (mA)
1
On-state resistance RON (Ω)
0.8
RON - Ta
On-state resistance RON (Ω)
0.6
-0.4
● On-state resistance vs.
Ambient temperature
G3VM-61CR1/61FR1
0
-40
G3VM-401CR/401FR:
Connection C
IO - VON
-4
0.025
0.8
G3VM-601CR/601FR:
Connection A, B
G3VM-401CR/401FR/601CR/601FR
0.1
0.01
0.6
1
0
-20
40
60
80
100
Ambient temperature Ta (°C)
Continuous load current IO (A)
0
Continuous load current IO (A)
-20
G3VM-601CR/601FR: Connection C
1.2
G3VM-401CR/401FR:
0.2 Connection A, B
2
0
-40
(Maximum value)
0.4
10
5
1.4
G3VM-@CR@/@FR@
15
12
G3VM-401CR/401FR/601CR/601FR
Continuous load current IO (A)
(Maximum value)
IO - Ta
DIP
LED forward current IF (mA)
IF - Ta
40
● Continuous load current vs.
Ambient temperature
G3VM-61CR1/61FR1
Continuous load current IO (A)
● LED forward current vs.
Ambient temperature
0
-40
-20
0
20
40
60
80 100
Ambient temperature Ta (°C)
● Turn ON, Turn OFF time vs. LED forward current
G3VM-61CR1/61FR1
G3VM-401CR/401FR/601CR/601FR
(Average value)
Ta=25°C
VDD=20V
RL=200Ω
1
tON
0.1
tON, tOFF - IF
Turn ON, Turn OFF time (ms)
Turn ON, Turn OFF time (ms)
tON, tOFF - IF
10
10
Ta=25°C
VDD=20V
RL=200Ω
G3VM-601CR/601FR
1
0.1
tON
G3VM-401CR
/401FR
tOFF
tOFF
G3VM-601CR/601FR
0.01
1
10
100
LED forward current (mA)
(Average value)
0.01
1
tON
10
100
LED forward current (mA)
4
G3VM-@CR@/@FR@
MOS FET Relays
■Engineering Data
● Turn ON, Turn OFF time vs.
Ambient temperature
G3VM-61CR1/61FR1
10
G3VM-401CR/401FR/601CR/601FR
(Average value)
VDD=20V, RL=200Ω, IF=5mA
tON
1
0.01
-40
tOFF
-20
0
20
40
60
80 100
Ambient temperature Ta (°C)
● Current leakage vs.Ambient temperature
Current Leakage ILEAK (μA)
G3VM-@CR@/@FR@
0.1
tON, tOFF - Ta
Turn ON, Turn OFF time tON, tOFF (ms)
DIP
Turn ON, Turn OFF time tON, tOFF (ms)
tON, tOFF - Ta
ILEAK - Ta (Average value)
1
VOFF=Load Voltage Ratings
0.1
G3VM-601CR/601FR
G3VM-61CR1/61FR1
0.01
0.001
G3VM-401CR/401FR
0.0001
-40
5
-20
0
20
40
60
80 100
Ambient temperature Ta (°C)
10
(Average value)
VDD=20V, RL=200Ω, IF=5mA
G3VM-601CR/601FR
1
tON
tON
G3VM-401CR/401FR
0.1
G3VM-601CR/601FR
0.01
-40
-20
0
tOFF
tOFF
20
40
60
80 100
Ambient temperature Ta (°C)
G3VM-@CR@/@FR@
MOS FET Relays
■Appearance / Terminal Arrangement / Internal Connections
●Appearance
●Terminal Arrangement/Internal Connections (Top View)
DIP (Dual Inline Package)
DIP 8-pin
8
7
6
5
1
2
3
4
Mold pin mark
(See note 3.)
OMRON logo
Model name (See note 2.)
932
DIP
61CR1
Pin 1 mark
LOT.NO.
G3VM-@CR@/@FR@
Note: 1. The actual product is marked differently from the image shown here.
Note: 2. “G3VM” does not appear in the model number on the Relay.
Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■Dimensions (Unit: mm)
DIP 8-pin
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
PCB Terminals
Weight: 0.54 g
Weight: 0.54 g
2.54
Eight, 0.8-dia. holes
(0.61)
2.54
9.66±0.25
9.66±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
0.8±0.25
(Recommended Value, Top View)
7.62±0.25
3.65+0.15
-0.25
2.54
0.25+0.1
-0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
3.65+0.15
-0.25
1.2±0.15
7.85 to 8.80
2.54±0.25
4.0+0.25
-0.2
1.0
min.
8.3 to 8.8
1.0 min.
10.0 max.
1.3
1.5
Note: The actual product is marked differently from the image shown here.
■Approved Standards
UL recognized
Model
Approved Standards
Contact form
File No.
G3VM-61CR1
G3VM-61FR1
G3VM-401CR
G3VM-401FR
Applying for UL recognition
G3VM-601CR
G3VM-601FR
■Safety Precautions
• Refer to the Common Precautions for All MOS FET Relays for precautions that apply to all MOS FET Relays.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K285-E1-01
0416(0416)(O)
6