MOS FET Relays G3VM-81LR World’s Smallest SSOP Package MOS FET Relay* with Low Output Capacitance and ON Resistance (C×R = 37.5pF•Ω) in a 80-V Load Voltage Model. • Turn-on time = 0.1 ms (typ.), Turn-off time = 0.15 ms (typ.) • RoHS compliant *Information correct as of May 2007, according to data obtained by OMRON. ■ Application Examples • Semiconductor inspection tools • Measurement devices • Broadband systems • Data loggers Note: The actual product is marked differently from the image shown here. ■ List of Models Contact form SPST-NO Terminals Surface-mounting terminals Load voltage (peak value) Model 80 VAC Number per tape G3VM-81LR --- G3VM-81LR(TR05) 500 G3VM-81LR(TR) 1,500 ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-81LR 4 3 4.2 416 228 1 2 1.9 14 dia. 3.65 0.15 Note: The actual product is marked differently from the image shown here. (0.3) 1.27 0.2 1.8 Note: A tolerance of ±0.1 mm applies to all dimensions unless otherwise specified. 3.8 2.04 (0.46) Weight: 0.03 g ■ Terminal Arrangement/Internal Connections (Top View) G3VM-81LR 4 3 1 2 ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-81LR 0.95 3.73 0.8 1.27 MOS FET Relays G3VM-81LR 275 ■ Absolute Maximum Ratings (Ta = 25°C) Item Input Symbol Rating Unit Measurement Conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP --- A 100 μs pulses, 100 pps LED forward current reduction rate Δ IF/°C −0.5 mA/°C Ta ≥ 25°C LED reverse voltage VR 5 V Connection temperature Tj 125 °C VOFF 80 V IO 120 mA Output Load voltage (AC peak/DC) Continuous load current Note: ON current reduction rate Δ IO/°C −1.2 mA/°C Connection temperature Tj 125 °C Dielectric strength between input and VI-O output (See note 1.) 1,500 Vrms AC for 1 min Ambient operating temperature −20 to +85 °C With no icing or condensation With no icing or condensation Ta Storage temperature Tstg −40 to +125 °C Soldering temperature --- 260 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Ta ≥ 25°C °C 10 s ■ Electrical Characteristics (Ta = 25°C) Item Input Minimum Symbol Typical Maximum Measurement conditions Unit LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR --- --- 10 μA VR = 5 V Capacity between terminals CT --- 15 --- pF V = 0, f = 1 MHz IFT --- 2 5 mA IO = 120 mA RON --- 7.5 12 Ω IF = 10 mA, IO = 120 mA, t = 10 ms Current leakage when the relay is open ILEAK --- 100 200 pA VOFF = 80 V, Ta = 60°C Capacity between terminals COFF --- 5 7 pF V = 0, f = 100 MHz, t<1s Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance between I/O terminals RI-O 1,000 --- --- MΩ VI-O = 500 VDC, RoH ≤ 60% Turn-ON time tON --- 0.1 0.25 ms Turn-OFF time tOFF --- 0.15 0.2 ms IF = 10 mA, RL = 200 Ω, VDD = 20 V (See note 2.) Trigger LED forward current Output Maximum resistance with output ON ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD --- --- 64 V Operating LED forward current IF 10 --- 30 mA Continuous load current (AC peak/DC) IO --- --- 120 mA Operating temperature 25 --- 60 °C 276 Ta MOS FET Relays G3VM-81LR Note: 2. Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF ■ Engineering Data Continuous load current vs. Ambient temperature IO - Ta 80 60 40 20 0 20 40 60 80 100 200 160 120 80 40 0 -20 120 0 Ambient temperature Ta (ഒ) Continuous load current vs. On-state voltage IO - VON On-state resistance RON (Ω) 60 80 100 100 50 0 -50 -100 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 0.5 0.3 0.8 I O = 120 mA I F = 10 mA 15 10 5 0 20 40 Turn ON, Turn OFF time tON, tOFF (μS) t OFF t ON 100 LED forward current IF (mA) 60 80 100 1000 300 t OFF 100 t ON 30 20 40 1.4 1.6 1.8 IO = 120 mA 4 3 2 1 0 -20 60 0 20 40 60 80 100 Current leakage vs. Load voltage I LEAK – VOFF VDD = 20 V RL = 200 Ω IF = 10mA 0 1.2 Ambient temperature Ta (ഒ) 3000 10 -20 1 5 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - Ta Ta = 25ഒ VDD =20 V, RL=200 Ω 10 3 Ambient temperature Ta (ഒ) 1000 10 1 5 Trigger LED forward current vs. Ambient temperature IFT - Ta 20 0 -20 1 Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 100 10 LED forward voltage VF (V) -150 -200 -1 30 0.1 0.6 120 Current leakage ILEAK (pA) Continuous load current IO (mA) Ta = 25 °C IF = 10 mA On-state voltage VON (V) Turn ON, Turn OFF time tON, tOFF (μS) 40 Ta = 25°C 50 On-state resistance vs. Ambient temperature RON - Ta 200 150 20 100 Ambient temperature Taഒ Trigger LED forward current I F T (mA) 0 -20 LED forward current vs. LED forward voltage IF - VF LED forward current I F (mA) 100 Continuous load current I O (mA) LED forward current IF (mA) LED forward current vs. Ambient temperature IF - Ta 80 100 15 Ta = 25 ഒ 10 5 0 Ambient temperature Ta (ഒ 20 40 60 80 Load voltage VOFF(v) Output terminal capacitance COFF/COFF(ov) vs. Load voltage COFF᧩VOFF 1.2 Output terminal capacitance COFF/COFF(ov) Ta T a = 25ഒ 25ഒ 1.0 0.8 0.6 0.4 0.2 0 0 10 20 Load voltage VOFF(v) 30 40 MOS FET Relays G3VM-81LR 277 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X302-E-1 MOS FET Relays 12/10 Specifications subject to change without notice G3VM-81LR Printed in USA