Datasheet

G3VM-61HR1
MOS FET Relays
Higher power, 3.3-A switching
with a 60-V load voltage,
SOP package. Low 30-mΩ
ON Resistance.
• Continuous load current of 3.3 A. (Connection C: 6.6 A)
Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
5
4
• Communication equipment
• Test & Measurement equipment
OMRON logo
• Data loggers
• Industrial equipment
2
1
Model name
61HR1
932
Pin 1 mark
LOT.No.
3
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
1a
Surface-mounting Terminals
(SPST-NO)
* The AC peak and DC value are given for the load voltage.
60 V
SOP6
Model
G3VM-61HR1
G3VM-61HR1 (TR05)
Minimum package quantity
Number per tube Number per tape and reel
75
500
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
reduction
Connection B
rate
Connection C
Pulse ON current
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
Rating
30
−0.3
5
125
60
3.3
3.3
6.6
−33
−33
−66
10
125
Unit
mA
mA/°C
V
°C
V
VI-O
1500
Vrms
Ta
Tstg
−40 to +85
−55 to +125
°C
°C
IO
∆IO/°C
Iop
TJ
-
260
A
mA/°C
A
°C
°C
Measurement conditions
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A: AC peak/DC
Connection B and C: DC
Connection A
Ta ≥ 25°C
t = 100 ms, Duty = 1/10
Connection B
1
6
Load
2
5
3
4
or AC
DC
1
6
2
5
3
4
1
6
2
5
3
4
Input
Output
1
DC
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection C
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.18
1.33
1.48
Reverse current
IR
10
Capacity between terminals
CT
70
Trigger LED forward current
IFT
0.2
3
Turn-OFF LED forward current
IFC
0.1
Connection A
30
60
Maximum
resistance
Connection B
RON
15
with output ON Connection C
8
Current leakage when the relay is open
ILEAK
20
Capacity between terminals
Coff
700
1500
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
108
Turn-ON time
tON
0.6
5
Turn-OFF time
tOFF
0.2
1
Load
Unit
V
µA
pF
mA
mA
mΩ
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
Note: 2. Turn-ON and Turn-OFF Times
IO = 2 A
IF 1
6 RL
IOFF = 10 µA
VDD
VOUT
IF = 5 mA, IO = 2 A, t < 1 s
2
4
IF = 5 mA, IO = 2 A, t < 1 s
IF = 5 mA, IO = 4 A, t < 1 s
VOFF = 60 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
Load
DC
G3VM-61HR1
MOS FET Relays
■ Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy
several conditions.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
48
Unit
V
Operating LED forward current
IF
5
10
25
mA
Continuous load current (AC peak/DC)
IO
-
-
3.3
A
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
Continuous load current vs.
Ambient temperature
IO - Ta
(Maximum value)
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
50
40
30
20
LED forward current vs.
LED forward voltage
(Maximum value)
8
7
6
Connection C
5
4
3
LED forward current IF (mA)
LED forward current vs.
Ambient temperature
IF - VF
(Average value)
100
Ta = 25°C
10
1
Connection A and B
2
0.1
10
1
-20
0
20
40
60
80
0
-40
100
-20
0
20
Ambient temperature Ta (°C)
Continuous load current vs.
On-state voltage
80
2
1
0
-1
90
80
IO = 2 A
IF = 5 mA, t < 1 s
Connection A
70
60
50
40
30
20
-3
1
1.5
2
LED forward voltage VF (V)
IFT - Ta
(Average value)
3
IO = 2 A, t < 1 s
2
1
10
-100
-50
0
50
100
0
-40
150
-20
0
On-state voltage VON (mV)
Turn ON, Turn OFF time vs.
LED forward current
tOFF
Ta = 25°C
VDD = 20 V
RL = 200 Ω
1
tON, tOFF - Ta
(Average value)
tON
0.1
10
60
80
100
0
-40
100
Turn ON, Turn OFF time vs.
Ambient temperature
10
1
40
-20
0
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFF (ms)
tON, tOFF - IF
20
40
60
80
100
Current leakage vs.
Ambient temperature
ILEAK - Ta
(Average value)
10
tON
1
0.1
20
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
-4
-150
Turn ON, Turn OFF time tON, tOFF (ms)
0.5
(Average value)
100
-2
0.01
0
Trigger LED forward current vs.
Ambient temperature
RON - Ta
(Average value)
Ta = 25°C
IF = 5 mA, t < 1 s
Connection A
0.01
100
On-state resistance vs.
Ambient temperature
4
3
60
Ambient temperature Ta (°C)
On-state resistance RON (mΩ)
Continuous load current IO (A)
IO - VON
40
Trigger LED forward current IFT (mA)
0
-40
tOFF
(Average value)
1000
VOFF = 60 V
100
10
1
VDD = 20 V
RL = 200 Ω
IF = 5 mA
0.01
-40
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
0.1
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■ Appearance
SOP (Small Outline Package)
SOP6
OMRON logo
61HR1
932
Pin 1 mark
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
4.4±0.25
6.3±0.25
(Recommended Value, TOP VIEW)
2.1 max.
6 to 6.3
1.2
0.15
0.8
2.54±0.25
Note: The actual product is marked differently from the image shown here.
0.1±0.1
0.4±0.1
0.6±0.3
7.0±0.4
2.54
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.