G3VM-21PR11 MOS FET Relays Smallest Class in market, USOP High-power, 0.9A Switching in a 20V Load Voltage Model • Dielectric strength of 500Vrms between I/O. Note: The actual product is marked differently from the image shown here. RoHS Compliant Refer to "Common Precautions". ■Application Examples ■Terminal Arrangement/Internal Connections • Communication • Semiconductor test Model name 2PB equipment equipment OMRON mark • Data loggers • Test & measurement LOT No. 103 equipment Note: The actual product is marked differently from the image shown here. ■List of Models Package type Contact form Load voltage (peak value) (See note.) Terminals Minimum package quantity Model Number per tape & reel − G3VM-21PR11 USOP4 1a (SPST-NO) Surface-mounting terminals 20V G3VM-21PR11 (TR05) 500 G3VM-21PR11 (TR) 1,500 Note 1. Ask you OMRON representative for orders under 1,500 pcs or 500 pcs. 2. Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. 3. The AC peak and DC value is given for the load voltages. U S O P Item LED forward current Input LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Output G 3 V M I 2 1 P R 1 1 ■Absolute Maximum Ratings (Ta = 25°C) Continuous load current (AC peak/DC) Symbol Rating Unit IF 50 mA ΔIF/°C −0.5 mA/°C VR 5 V °C TJ 125 VOFF 20 V IO 900 mA Measurement conditions ΔIO/°C −12 mA/°C Pulse ON current lop 2700 mA Connection temperature TJ 125 °C ON current reduction rate Ta≥25°C Ta≥50°C t=100ms, Duty=1/10 Dielectric strength between I/O (See note 1.) VI-O 500 Vrms Ambient operating temperature Ta −40~+85 °C Tstg −40~+125 °C With no icing or condensation − 260 °C 10s Ambient storage temperature Soldering temperature AC for 1 min With no icing or condensation Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum Unit Measurement conditions VF 1.0 1.15 1.3 V IF=10mA Reverse current IR − − 10 μA VR=5V Capacity between terminals CT − 15 − pF V=0, f=1MHz Trigger LED forward current IFT − 0.6 3 mA IO=100mA Maximum resistance with output ON RON − 0.18 0.22 Ω IF=5mA, IO=900mA, t<1s Current leakage when the relay is open ILEAK − − 1 nA VOFF=20V, Ta=25°C Capacity between terminals COFF − 40 − pF V=0, f=100MHz, t<1s Capacity between I/O terminals CI-O − 0.4 − pF f=1MHz, VS=0V Insulation resistance between I/O terminals RI-O 1000 − − MΩ VI-O=500VDC, ROH≤60% Turn-ON time tON − 0.5 2 ms Turn-OFF time tOFF − 0.1 1 ms IF=5mA, RL=200Ω, VDD=10V (See note 2.) Input LED forward voltage Output 1 Note: 2. Turn-ON and Turn-OFF Times IF 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF G3VM-21PR11 MOS FET Relays ■Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD − − 16 V IF 5 7.5 20 mA Load voltage (AC peak/DC) Operating LED forward current Unit Continuous load current (AC peak/DC) IO − − 900 mA Ambient operating temperature Ta −20 − 65 °C ■Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 60 50 40 30 20 10 1000 800 600 400 -20 0 20 40 60 80 -20 0 Ta=25°C IF=5mA t<1s 0 -500 40 60 80 Io=900mA 0.4 0.1 0.2 IF=5mA t<1s 0.3 0.2 -40 -20 0 Turn ON, Turn OFF time vs. LED forward current 20 40 60 80 100 Io=100mA t<1s 1 0 -40 -20 0 Turn ON, Turn OFF time vs. Ambient temperature Turn ON, Turn OFF time tON, tOFF (µs) tOFF 100 VDD=10V tON RL=200Ω Ta=25°C 10 10 100 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Load voltage tON, tOFF - Ta 1000 1.6 2 Ambient temperature Ta (°C) tON, tOFF - IF 1.4 IFT - Ta 0.5 On-state voltage VON (V) 1 1.2 LED forward voltage VF (V) U S O P ILEAK - VOFF Current leakage ILEAK (pA) 0 1 Trigger LED forward current vs. Ambient temperature 0 -0.1 0.8 100 0.1 -1000 -0.2 1 RON - Ta On-state resistance RON (Ω) Continuous load current IO (mA) 20 On-state resistance vs. Ambient temperature IO - VON 1000 500 10 Ambient temperature Ta (°C) Ambient temperature Ta (°C) Continuous load current vs. On-state voltage Ta=25°C 0.1 -40 100 Trigger LED forward current IFT (mA) -40 100 200 0 0 Turn ON, Turn OFF time tON, tOFF (µs) IF - VF LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage tON 1000 tOFF 100 VDD=10V 100 Ta=25°C 80 G 3 V M I 2 1 P R 1 1 60 40 20 RL=200Ω IF=5mA 0 10 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) 0 5 10 15 20 Load voltage VOFF (v) Output terminal capacitance COFF/COFF(ov) vs. Load voltage Output terminal capacitance COFF/COFF(ov) COFF - VOFF 1.2 Ta=25°C 1 0.8 0.6 0.4 0.2 0 0 5 10 15 20 Load voltage VOFF (v) ■Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Apperance/Dimensions USOP4 ■Appearance USOP (Ultra Small Outline Package) USOP4 2PB Model name OMRON mark 103 LOT NO. Note: The actual product is marked differently from the image shown here. ■Dimensions 2PB (Unit: mm) Surface-mounting Terminals 103 Actual Mounting Pad Dimensions Weight: 0.03g 3.25 (Recommended Value, Top View) 2.05 0.85 2.9 0.15 1.65 (0.4) 1.27 0.2 0.8 2.85 1.27 2.2 (0.35) Note: The actual product is marked differently from the image shown here. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K196-E1-02 1112(0912)(O)