View

REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
A
Paragraph 1.4; added Vcontrol range (Voltages are relative to VOUT)
+2 V to +36 V. Figure 2; corrected the terminal symbol names.
Figure 3; corrected the terminal symbol names and locations. -sld
13-03-06
Charles F. Saffle
B
Made corrections to paragraphs 1.3 and 1.4. Table I: Made
corrections to the Set pin current, Line regulation, Load regulation,
Dropout voltage, and Current limit tests. -sld
14-04-24
Charles F. Saffle
REV
SHEET
REV
B
B
SHEET
15
16
REV STATUS
OF SHEETS
PMIC N/A
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
REV
B
B
B
B
B
B
B
B
B
B
B
B
B
B
SHEET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
PREPARED BY
Steve L. Duncan
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
CHECKED BY
Greg Cecil
APPROVED BY
Charles F. Saffle
DRAWING APPROVAL DATE
13-02-13
REVISION LEVEL
B
http://www.landandmaritime.dla.mil/
MICROCIRCUIT, HYBRID, DUAL VOLTAGE
REGULATOR ULTRA LOW DROPOUT, POSITIVE,
ADJUSTABLE
SIZE
A
SHEET
DSCC FORM 2233
APR 97
CAGE CODE
5962-13203
67268
1 OF
16
5962-E270-14
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962



Federal
stock class
designator
\
R



RHA
designator
(see 1.2.1)
\/
Drawing number
13203
/
01



Device
type
(see 1.2.2)
K



Device
class
designator
(see 1.2.3)
X



Case
outline
(see 1.2.4)
C



Lead
finish
(see 1.2.5)
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
01
Generic number
8667, 8668
Circuit function
Dual voltage regulator, positive , low dropout, adjustable
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All
levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and
E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
Device performance documentation
K
Highest reliability class available. This level is intended for use in space
applications.
H
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
G
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C and D).
E
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must be
specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
D
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
2
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
U
Z
Descriptive designator
See figure 1
See figure 1
Terminals
Package style
8
8
Thru-hole
Surface Mount
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
1.3 Absolute maximum ratings. 1/
Input voltage range, Vcontrol (Voltages are relative to VOUT) ......
Output current ............................................................................
Input-Output differential voltage .................................................
Output voltage ...........................................................................
Operating junction temperature range .......................................
Thermal Resistance, Junction temperature (ӨJC) ......................
Lead temperature (soldering, 10 seconds) ................................
Storage temperature range ........................................................
+40 V dc, -0.3 V dc
1.2 A
26 V dc
36 V dc
-55°C to +150°C
7°C/W
+300°C
-65°C to +150°C
1.4 Recommended operating conditions.
Input voltage range (Voltages are relative to VOUT) .....................
Vcontrol range (Voltages are relative to VOUT) ..............................
Output voltage range ..................................................................
Input-Output differential voltage range ........................................
Case operating temperature range (TC) ......................................
+1.0 V to +36 V dc
+1.6 V to +36 V
0 V to +35 V dc
.5 V to 26 V dc
-55°C to +125°C
1.5 Radiation features. 2/
Maximum total dose available (Dose rate = 50 - 300 rad(Si)/s)
...............................................................................................
Enhanced Low Dose Rate Sensitvity (ELDRS):
(dose rate ≤ 10 mrad(Si)/s) .......................................................
100 krad(Si) 3/
50 krad(Si) 4/
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
________
1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
2/ Bipolar device types may degrade from displacement damage from radiation which could affect RHA levels. These device
types have not been characterized for displacement damage.
3/ The active elements that make up these devices on this drawing have been tested for Total Ionizing Dose (TID) in accordance
with MIL-STD-883 test method 1019 condition A. RHA testing of the active elements covered on this SMD are tested in
alternate package (TO3), not the packages as specified in paragraph 1.2.4.
4/ The active elments that make up this device has been tested to RHA designator level "R" (100 krad(Si)) of Method 1019,
condition A of MIL-STD-883 and low dose rate tested to the requirements of Method 1019, condition D and paragraph 3.13.1
of MIL-STD-883 to 50 krad(Si) at +25°C. No ELDRS effect was observed. The elements will be re-tested after design or
process changes that can affect RHA response of these elements. RHA testing of the active elements covered on this SMD
were done in alternate package (TO3), not the packages as specified in paragraph 1.2.4.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
3
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at http://quicksearch.dla.mil/ or from the Standardization Document Order
Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of
this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific
exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. The
manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as
defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not
affect the form, fit, or function of the device for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in
MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Block diagram. The block diagram shall be as specified on figure 3.
3.2.4 Maximum power dissipation verses case temperature chart. The maximum power dissipation verses case temperature is
specified on figure 4.
3.2.5 Radiation exposure circuit. The radiation exposure circuit shall be maintained by the manufacturer under document
revision level control and shall be made available to the preparing and acquiring activity upon request.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as
specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample,
for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those
which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be
made available to the preparing activity (DLA Land and Maritime -VA) upon request.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
4
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime -VA shall affirm that the manufacturer's
product meets the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
5
TABLE I. Electrical performance characteristics.
Test
Symbol
Set pin current
Conditions
-55°C ≤ TC ≤+125°C
VCONTROL = 2.0 V, P ≤ PMAX,
unless otherwise specified
Group A
subgroups
Device
type
1,2,3
Limits
Unit
Min
Max
01
9.85
10.35
µA
IREF1
1.0 mA ≤ IOUT ≤ 1.0 A,
VIN - VOUT = 1.6 V
IREF2
VIN = 1 V, VCONTROL = 2.0 V, 1/
IOUT = 1 mA
Output offset voltage
1/
VOS
VIN = 2 V, IOUT = 1 mA
1,2,3
01
-9.0
+9.0
mV
Line regulation 1/
∆VOS
2.0 V ≤ VCONTROL ≤ 26 V
1.6 V ≤ VIN - VOUT ≤ 25 V,
ILOAD = 1 mA
1,2,3
01
-0.15
0.15
mV/V
Load regulation 1/
∆VOS
1.0 mA ≤ IOUT ≤ 100 mA, (VIN - VOUT)
=3V
1,2,3
01
-1.4
1.4
mV
1
01
0.03
%/W
1,2,3
01
1.65
V
Thermal regulation
30 ms pulse, TC = +25°C
VCONTROL dropout
voltage
VCDROP
VIN dropout voltage
VINDROP
IOUT = 1.0 A, VCONTROL = VIN
IOUT = 0.1 A, VCONTROL = VIN
1/ 2/
1.65
IOUT = 1.0 A, VCONTROL ≥ 1.6 V
IOUT = 0.1 A, VCONTROL ≥ 1.6 V
01
1/ 2/
0.25
Current limit
IMAX
VIN = VCONTROL = 5 V, VOUT = 0.1 V,
TC = +25°C
1
01
Minimum load current
1/ 2/
IMIN
VIN = VCONTROL = 26 V, VOUT = 0.1 V
1,2,3
01
IOUT = 0.2 A, (VIN - VOUT) = 3 V,
f = 120 Hz, COUT = 2.2 µF, CSET = 0.1
µf
1,2,3
01
Ripple rejection
0.5
1.1
A
0.9
mA
60
dB
1/
The active elments that make up this device has been tested to RHA designator level "R" (100 krad(Si)) of Method 1019,
condition A of MIL-STD-883 and low dose rate tested to the requirements of Method 1019, condition D and paragraph 3.13.1
of MIL-STD-883 to 50 krad(Si) at +25°C for these parameters and limits. No ELDRS effect was observed. The elements will
be re-tested after design or process changes that can affect RHA response of these elements. RHA testing of the active
elements covered on this SMD were done in alternate package (TO3), not the packages as specified in paragraph 1.2.4.
2/
Not tested. Shall be guaranteed by design, characterization, or correlation to other tested parameters.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
6
Case U
FIGURE 1. Case outline(s).
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
7
Case U - Continued.
Inches
Symbol
Min
A
Millimeters
Max
Min
.220
Max
5.59
∅b
.028
.032
0.71
0.81
∅b3
.085
.095
2.12
2.41
D
.750
.760
19.05
19.30
D1
.510
.520
12.95
13.21
e
.100 BSC
2.54 BSC
e1
.300 BSC
7.62 BSC
e2
.108 BSC
2.74 BSC
eA
.700
.740
17.78
18.80
E
.410
.420
10.41
10.67
F
.035
.045
0.90
1.14
G1
.632 BSC
G2
.2025
L1
.230
L2
16.05 BSC
.2125
5.144
5.84
.150 REF
.140
∅p
5.408
3.81 REF
.150
3.56
3.81
Q
.122 TYP
3.10 TYP
R
.065 TYP
1.65 TYP
S1
.028
0.71
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
2. The package contains a BeO substrate.
3. The case is electrically isolated.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
8
Case Z
FIGURE 1. Case outlines(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
9
Case Z - Continued.
Inches
Symbol
Min
Millimeters
Max
A
Min
Max
.220
5.59
A1
.015
.025
0.38
0.64
∅b
.028
.032
0.71
0.81
∅b3
.085
.095
2.12
2.41
D
.750
.760
19.05
19.30
D1
.510
.520
12.95
13.21
e
.100 BSC
2.54 BSC
e1
.300 BSC
7.62 BSC
e2
.108 BSC
2.74 BSC
E
.410
.420
10.41
10.67
F
.035
.045
0.90
1.14
G1
.632 BSC
16.05 BSC
G2
.2025
.2125
5.144
5.408
H
.866
.906
22.00
23.01
L1
.055
.065
1.40
1.65
L2
.150 REF
.140
∅p
3.81 REF
.150
3.56
3.81
Q
.122 TYP
3.10 TYP
R
.065 TYP
1.65 TYP
S1
.028
0.71
NOTES:
1. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
2. The package contains a BeO substrate.
3. The case is electrically isolated.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
10
Device type
Case outlines
Terminal number
01
U and Z
Terminal symbol
1
2
3
4
5
6
7
8
VCONTROL_1
VIN_1
VCONTROL_2
VIN_2
VOUT_2
SET_2
VOUT_1
SET_1
FIGURE 2. Terminal connections.
FIGURE 3. Block diagram.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
11
Case
temperature
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
One
Regulator
On
23.08
22.31
21.54
20.77
20.00
19.23
18.46
17.69
16.92
16.15
15.38
14.62
13.85
13.08
12.31
11.54
10.77
10.00
9.23
8.46
7.69
6.92
6.15
5.38
4.62
3.85
3.08
2.31
1.54
0.77
0.00
Two
Regulators
On
42.86
41.43
40.00
38.57
37.14
35.71
34.29
32.86
31.43
30.00
28.57
27.14
25.71
24.29
22.86
21.43
20.00
18.57
17.14
15.71
14.29
12.86
11.43
10.00
8.57
7.14
5.71
4.29
2.86
1.43
0.00
FIGURE 4. Maximum power dissipation verses case temperature chart.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
12
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A
test table)
Interim electrical parameters
1
Final electrical parameters
1*,2,3
Group A test requirements
1,2,3
Group C end-point electrical
parameters
1,2,3
End-point electrical parameters
for Radiation Hardness Assurance
(RHA) devices
1
* PDA applies to subgroup 1.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified
in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or
function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a.
b.
Burn-in test, method 1015 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also,
the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the
intent specified in method 1015 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1015 of MIL-STD-883.
Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests
prior to burn-in are optional at the discretion of the manufacturer.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
Tests shall be as specified in table II herein.
b.
Subgroups 4, 5, 6, 7, 8A, 8B, 9, 10, and 11 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
13
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
End-point electrical parameters shall be as specified in table II herein.
b.
Steady-state life test, method 1005 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also,
the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the
intent specified in method 1005 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1005 of MIL-STD-883.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5. Radiation hardness assurance (RHA). RHA qualification is required only for those devices with the RHA designator as
specified herein. See table IIIA and table IIIB.
Table IIIA. Radiation Hardness Assurance Method Table.
RHA
method
Employed
Testing at 1X rated
for total dose
Worst Case Analysis Performed
No
Element Hybrid Device Includes
Combines
Combines End-of-life
Level
Level
temperature temperature and total dose
effects
radiation effects
and
displacement
effects
Yes
NOTES:
X =
G =
(N) =
N/A =
Yes
See
4.3.5.1.1.2
N/A
N/A
N/A
End points after dose is
achieved includes minimum
maximum, and room
temperatures
Element Level Hybrid device
level
N/A
No
No
Radiation testing done (Level)
Guaranteed by design or process
Not yet tested
Not applicable for this SMD
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
14
Table IIIB. Hybrid level and element level test table.
Low Dose Rate
Hybrid
Element
Bipolar, linear
or mixed signal
> 90 nm
NOTES:
X =
G =
(N) =
N/A =
Total Dose
High Dose
Rate (HDR)
Radiation Test
Heavy Ion
Proton
Neutron
ELDRS
SEU
SEL
Low
High
SEE Displacement
(upset) (latch-up) Energy Energy (upset) Damage (DD)
X
X
X
See 4.3.5.1.1.2 See 4.3.5.1.1.2 See 4.3.5.1.1.2
X
(50 krad)
X
(100 krad)
X
(50 krad)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
Radiation testing done (Level)
Guaranteed by design or process
Not yet tested
Not applicable for this SMD
4.3.5.1 Radiation Hardness Assurance (RHA) inspection. RHA qualification is required for those devices with the RHA
designator as specified herein. End-point electrical parameters for radiation hardness assurance (RHA) devices shall be
specified in table II. Radiation testing will be in accordance with the qualifying activity (DLA Land and Maritime -VQ) approved
plan and with MIL-PRF-38534, Appendix G.
a.
The hybrid device manufacturer shall establish procedures controlling component radiation testing, and shall establish
radiation test plans used to implement component lot qualification during procurement. Test plans and test reports shall
be filed and controlled in accordance with the manufacturer's configuration management system.
b.
The hybrid device manufacturer shall designate a RHA program manager to oversee component lot qualification, and to
monitor design changes for continued compliance to RHA requirements.
4.3.5.1.1 Hybrid level qualification.
4.3.5.1.1.1 Qualification by similarity. This device has not been indentified as "similar".
4.3.5.1.1.2 Total ionizing dose irradiation testing. Hybrid level and element level testing are the same for the device on
this SMD since the active elements are independent of each other and accessible to the device leads for test. The qualification
was performed on the active elements, independent of the hybrid.
4.3.5.1.2 Element level qualification.
4.3.5.1.2.1 Total Ionizing dose irradiation testing. A minimum of ten samples of each element is tested at initial qualification
and after any design or process changes which may affect the RHA response of the device type. Five biased and five unbiased
are tested at High Dose Rate (HDR) in accordance with condition A of method 1019 of MIL-STD-883 to 100 krad(Si). In addition
another ten devices are tested at Low Dose Rate (LDR) in accordance with method 1019, condition D and paragraph 3.13.1 of
MIL-STD-883 to 50 krad(Si). The resulting data is evaluated in accordance with Condition D, ELDRS characterization.
0.9000/90% statistics are applied to the device parameters as specifed in table I herein.
4.3.5.2 Radiation Lot Acceptance. Each wafer lot of active elements shall be evaluated for acceptance in accordance with MILPRF-38534 and herein.
4.3.5.2.1 Total Ionizing Dose. Samples from every wafer lot will be assembled into the package (TO3) and tested for wafer lot
acceptance Radiation Lot Acceptance Testing (RLAT). Five biased and five unbiased devices are tested in accordance with
condition A, of method 1019 of MIL-STD-883 to 100 krad(Si). 0.9000/90% statistics are applied to the device parameters as
specifed in table I herein.
4.3.5.2.2 Technologies not tested. All active components in these devices are RHA tested.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
15
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractorprepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF38534.
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
configuration control and the applicable SMD. DLA Land and Maritime will maintain a record of users and this list will be used for
coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should
contact DLA Land and Maritime -VA, telephone (614) 692-8108.
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime -VA, Columbus, Ohio 43218-3990, or
telephone (614) 692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103
and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DLA Land and Maritime -VA and have agreed to
this drawing.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-13203
A
REVISION LEVEL
B
SHEET
16
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 14-04-24
Approved sources of supply for SMD 5962-13203 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime -VA. This information
bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. DLA Land and Maritime
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962R1320301KUA
5962R1320301KUC
5962R1320301KZA
5962R1320301KZC
88379
88379
88379
88379
VRG8667-901-2S
VRG8667-901-1S
VRG8668-901-2S
VRG8668-901-1S
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the Vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
Vendor CAGE
number
88379
Vendor name
and address
Aeroflex Plainview Incorporated,
(Aeroflex Microelectronic Solutions)
35 South Service Road
Plainview, NY 11803
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.