10W AC-DC Power-Supply PAC10C ● ● ● ● ● ● ● Enclosed plastic case 85 … 264 VAC or 120 … 370 VDC universal input range Continuously short circuit protected Over voltage protected Isolation class II MTBF > 300000 hours 3 years product warranty Model guide Output voltage Type [VDC] Single output PAC10C03S PAC10C05S PAC10C09S PAC10C12S PAC10C15S PAC10C24S Dual outputs PAC10C05D PAC10C12D PAC10C15D PAC10C24D Type Dual isolated outputs PAC10C0505DI PAC10C0512DI PAC10C0515DI PAC10C0524DI Output voltagetolerance [%] typ. Output current Efficiency @ full load [mA] max. [%] typ. 3.3 5.0 9.0 12 15 24 ±3 ±2 ±2 ±2 ±2 ±2 2000 2000 1100 900 700 450 70 76 78 80 81 82 ±5.0 ±12 ±15 ±24 ±2 ±2 ±2 ±2 ±1000 ±450 ±350 ±200 76 80 81 84 Main output voltage Vout 1 [VDC] Main output current Iout 1 [mA] max. Auxiliary output voltage Vout 2 [VDC] Auxiliary output current Iout 2 [mA] max. Efficiency @ full load 5 5 5 5 1800 1500 1400 1000 5 12 15 24 200 200 200 200 75 79 79 81 [%] typ. Page 1 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W AC-DC Power-Supply PAC10C Specification Input Voltage range Line frequency range Full load input current Inrush current Recommended fuse Isolation Isolation voltage (input to output) Leakage current Output Voltage accuracy Line regulation Temperature coefficient Ripple & noise up to 20 MHz Output load stability @ load change 10 to 100 % Minimum load (Percent of full load) Protection Short circuit Over current Over temperature Output over voltage protection (external TVS D1 see Fig.1) General Switching frequency Hold up time @ full load Reliability MTBF @ 25°C 85..264 VAC or 120..370 VDC Power derating see diagram 47…63 Hz 230 mA @ 115 VAC, typ. 120 mA @ 230 VAC, typ. 10 A typ. @ 115 VAC 20 A typ. @ 230 VAC 2 A / 250V slow blow 3000 VAC for 1 min. 0.3 mA typ. @ Vin 230 VAC / 50 Hz ±2% Main output: ± 0.5 % Auxiliary output: ± 1.5 % Main output: ± 0.02 % / °C Auxiliary output: ± 0.15 % / °C 100 mVp-p max. (see figure A) Single output: ± 1 % Dual output: ± 2 % @ balanced load Dual isolated output Vo1: ± 3 %, Vo2: ± 5 % @ balanced load Single output: not required Dual output: 10 % on Vo 1 Dual output isolated: 10 % on Vo 1 Continuous, auto recovery 110 %, min. of full load 150 °C, max. PAC10C03X: < 7.5 VDC PAC10C05X: < 7.5 VDC PAC10C09X: < 12 VDC PAC10C12X: < 20 VDC PAC10C15X: < 20 VDC PAC10C24X: < 30 VDC EMC compliance CE: EN55011 (CISPR22), class B EMI: Conducted & Radiation (EMC application circuit is required, RE: EN55011 (CISPR22), class B see figure 2) IEC-, EN61000-4-2, air ± 8 kV, ESD: Electrostatic discharge contact ± 6 kV, perf. Criteria B IEC-, EN61000-4-3, 10 V / m, RS: field susceptibility perf. Criteria A IEC, EN61000-4-4, ± 2 kV, perf. Criteria B Without external circuit EFT: Fast transients on mainsline IEC, EN61000-4-4, ± 4 kV, perf. Criteria B With recommended circuit refer to figure 1 IEC, EN61000-4-5, ±1 kV / ± 2 kV, Surge: External circuit is required perf. Criteria B to converter at inrush and fast Without external circuit transient test, refer to typical IEC, EN61000-4-5, ±2 kV / ± 4 kV, application! perf. Criteria B With recommended circuit refer to figure 1 IEC-, EN61000-4-6, 10 Vrms, CS: perf. Criteria A IEC-, EN61000-4-8, 10 A / m, PFM: perf. Criteria A IEC-, EN61000-4-11, 0 %...70 %, Voltage dips, short and perf. Criteria B interruptions immunity Safety approvals IEC60950, EN60950, UL60950 Safety Class I Environmental Operating temperature (ambient) -40 °C to 70 °C (with derating) Case temperature 90 °C, max. Storage temperature -40 °C to +105 °C Power derating above 55°C and 3.75 % per °C, see diagram below 0°C Humidity 85 %, non condensing Cooling Free air convection Physical Dimensions 55 x 45 x 21 mm Weight 80 g Case material UL94V-0 rated Soldering temperature 260 °C, 10 s, 1.5 mm from case 65 kHz typ. 15 ms @ 115 VAC typ. 80 ms @ 230 VAC typ. >300000 h Figure A Output ripple & noise measure circuit Conductor track Oscilloscope probe L AC AC line voltage DC C1 C2 Load 10µF 100nF N 25.4mm 25.4mm Page 2 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W AC-DC Power-Supply PAC10C Page 3 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W AC-DC Power-Supply PAC10C PAC10C L +Vout -Vout N PE This connection is not supported for the PAC10C Typical application circuit Figure 1a, single output L F1 PAC10CxxS R1 L ϑ U N C1 C2 D1 +Vout +Vo R2 N -Vout -Vo PE PE Figure 1b, ± dual output L F1 PAC10CxxD R1 L ϑ U N R2 +Vo C1a C2a D1a +Vout Com Com N PE PE -Vout -Vo C1b C2b D1b C1 C2a D1a +Vout 1 Figure 1c, isolated dual output L F1 PAC10CxxDI R1 L ϑ N U -Vout 1 -Vo1 R2 N PE PE +Vo1 +Vo2 +Vout 2 -Vo2 C7 C2b D1b -Vout 2 Page 4 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W AC-DC Power-Supply PAC10C Application circuit and example for ripple and noise reduction Figure 2 L Rs F1 PAC10C L1 PIF001A L Cy Cy V Cy U Cx +V out Rd +V out Cy PE C1 C2 D1 -V out -V out Rs N N PE PIF 001A is an integrated PHI-CON filter module which contains all components in the framed field of figure 2. Table 1 C1 C2 C7 [µF] F1 slow blow fuse R1 NTC type R2 MOV type D1 TVS type C4/5 Y type [pF] C6 X type [nF] [nF] Single output PAC10C03S 100 PAC10C05S 100 PAC10C09S 100 PAC10C12S 100 PAC10C15S 100 PAC10C24S 100 ± Dual output PAC10C05D 100 PAC10C12D 100 PAC10C15D 100 PAC10C24D 100 Dual output isolated PAC10C0505DI 100 PAC10C0512DI 100 PAC10C0515DI 100 PAC10C0524DI 100 [µF] [mH] 330 330 120 120 120 68 - 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ NTC 5D-9 NTC 5D-9 NTC 5D-9 NTC 5D-9 NTC 5D-9 NTC 5D-9 471KD14 471KD14 471KD14 471KD14 471KD14 471KD14 P6KE6.8A P6KE6.8A P6KE12A P6KE20A P6KE20A P6KE30A 2200 2200 2200 2200 2200 2200 100 100 100 100 100 100 10..30 10..30 10..30 10..30 10..30 10..30 220 120 47 33 - 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ NTC 5D-9 NTC 5D-9 NTC 5D-9 NTC 5D-9 471KD14 471KD14 471KD14 471KD14 P6KE6.8A P6KE6.8A P6KE6.8A P6KE6.8A 2200 2200 2200 2200 100 100 100 100 10..30 10..30 10..30 10..30 220 220 220 220 68 68 47 47 2A / 250V~ 2A / 250V~ 2A / 250V~ 2A / 250V~ NTC 5D-9 NTC 5D-9 NTC 5D-9 NTC 5D-9 471KD14 471KD14 471KD14 471KD14 P6KE6.8A P6KE6.8A P6KE6.8A P6KE6.8A 2200 2200 2200 2200 100 100 100 100 10..30 10..30 10..30 10..30 Model L1 Note: 1. Output filtering capacitor C2 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C1 is a ceramic capacitor, it is used to filter high frequency noise. TVS D1 is a recommended component to protect post-circuits (if converter fails). 2. The varistor R2 protect the device under surge. 3. Recommended fuse parameter for F1 are 2 A / 250 V slow blow. A external input NTC limited the inrush current. Recommended model is NTC 5D-9. (see figure 1 and R1 table 1) 4. If common requirement to EMC performance (EN55011 Class A), refer to figure 1. If higher requirement to EMC performance (EN55011 Class B), refer to figure 2. C6: X capacitor, recommended values 0.1 μF / 275 V; C4, C5: Y capacitor, recommended values 2200 pF / 400 V; L1: common mode choke, recommended inductance is about 10 mH – 30 mH. Page 5 of 6 10W AC-DC Power-Supply PAC10C EMC application circuit recommended PCB Layout Safety and recommend wiring, line width A >3mm, space B > 6 mm, space C > 9 mm Dimensions Pin connection Note: Unit: mm Pin diameter tolerance: ± 0.1 mm Pin length: >6 mm General tolerances: ± 0.5 mm Pin 1 2 3 4 5 6 7 8 Pin configuration Single Dual PE N L - V out omitted omitted omitted + V out PE N L - V out omitted common omitted + V out Dual isolated PE N L - V out 1 + V out 1 omitted - V out 2 + V out 2 PHI-CON is a trademark of HY-LINE Power Components. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 04.14 f Page 6 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]