Download

10W AC-DC Power-Supply PAC10C
●
●
●
●
●
●
●
Enclosed plastic case
85 … 264 VAC or 120 … 370 VDC universal input range
Continuously short circuit protected
Over voltage protected
Isolation class II
MTBF > 300000 hours
3 years product warranty
Model guide
Output voltage
Type
[VDC]
Single output
PAC10C03S
PAC10C05S
PAC10C09S
PAC10C12S
PAC10C15S
PAC10C24S
Dual outputs
PAC10C05D
PAC10C12D
PAC10C15D
PAC10C24D
Type
Dual isolated outputs
PAC10C0505DI
PAC10C0512DI
PAC10C0515DI
PAC10C0524DI
Output
voltagetolerance
[%] typ.
Output current
Efficiency @ full load
[mA] max.
[%] typ.
3.3
5.0
9.0
12
15
24
±3
±2
±2
±2
±2
±2
2000
2000
1100
900
700
450
70
76
78
80
81
82
±5.0
±12
±15
±24
±2
±2
±2
±2
±1000
±450
±350
±200
76
80
81
84
Main output
voltage
Vout 1
[VDC]
Main output
current
Iout 1
[mA] max.
Auxiliary output
voltage
Vout 2
[VDC]
Auxiliary output
current
Iout 2
[mA] max.
Efficiency @ full
load
5
5
5
5
1800
1500
1400
1000
5
12
15
24
200
200
200
200
75
79
79
81
[%] typ.
Page 1 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
10W AC-DC Power-Supply PAC10C
Specification
Input
Voltage range
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to output)
Leakage current
Output
Voltage accuracy
Line regulation
Temperature coefficient
Ripple & noise up to 20 MHz
Output load stability @ load
change 10 to 100 %
Minimum load
(Percent of full load)
Protection
Short circuit
Over current
Over temperature
Output over voltage protection
(external TVS D1 see Fig.1)
General
Switching frequency
Hold up time @ full load
Reliability MTBF @ 25°C
85..264 VAC or 120..370 VDC
Power derating see diagram
47…63 Hz
230 mA @ 115 VAC, typ.
120 mA @ 230 VAC, typ.
10 A typ. @ 115 VAC
20 A typ. @ 230 VAC
2 A / 250V slow blow
3000 VAC for 1 min.
0.3 mA typ. @ Vin 230 VAC / 50 Hz
±2%
Main output: ± 0.5 %
Auxiliary output: ± 1.5 %
Main output: ± 0.02 % / °C
Auxiliary output: ± 0.15 % / °C
100 mVp-p max.
(see figure A)
Single output: ± 1 %
Dual output: ± 2 %
@ balanced load
Dual isolated output
Vo1: ± 3 %, Vo2: ± 5 %
@ balanced load
Single output: not required
Dual output: 10 % on Vo 1
Dual output isolated:
10 % on Vo 1
Continuous, auto recovery
110 %, min. of full load
150 °C, max.
PAC10C03X: < 7.5 VDC
PAC10C05X: < 7.5 VDC
PAC10C09X: < 12 VDC
PAC10C12X: < 20 VDC
PAC10C15X: < 20 VDC
PAC10C24X: < 30 VDC
EMC compliance
CE: EN55011 (CISPR22), class B
EMI: Conducted & Radiation
(EMC application circuit is required,
RE: EN55011 (CISPR22), class B
see figure 2)
IEC-, EN61000-4-2, air ± 8 kV,
ESD: Electrostatic discharge
contact ± 6 kV, perf. Criteria B
IEC-, EN61000-4-3, 10 V / m,
RS: field susceptibility
perf. Criteria A
IEC, EN61000-4-4, ± 2 kV, perf. Criteria B
Without external circuit
EFT: Fast transients on mainsline
IEC, EN61000-4-4, ± 4 kV, perf. Criteria B
With recommended circuit refer to figure 1
IEC, EN61000-4-5, ±1 kV / ± 2 kV,
Surge: External circuit is required perf. Criteria B
to converter at inrush and fast
Without external circuit
transient test, refer to typical
IEC, EN61000-4-5, ±2 kV / ± 4 kV,
application!
perf. Criteria B
With recommended circuit refer to figure 1
IEC-, EN61000-4-6, 10 Vrms,
CS:
perf. Criteria A
IEC-, EN61000-4-8, 10 A / m,
PFM:
perf. Criteria A
IEC-, EN61000-4-11, 0 %...70 %,
Voltage dips, short and
perf. Criteria B
interruptions immunity
Safety approvals
IEC60950, EN60950, UL60950
Safety
Class I
Environmental
Operating temperature (ambient)
-40 °C to 70 °C (with derating)
Case temperature
90 °C, max.
Storage temperature
-40 °C to +105 °C
Power derating above 55°C and
3.75 % per °C, see diagram
below 0°C
Humidity
85 %, non condensing
Cooling
Free air convection
Physical
Dimensions
55 x 45 x 21 mm
Weight
80 g
Case material
UL94V-0 rated
Soldering temperature
260 °C, 10 s, 1.5 mm from case
65 kHz typ.
15 ms @ 115 VAC typ.
80 ms @ 230 VAC typ.
>300000 h
Figure A
Output ripple & noise measure circuit
Conductor track
Oscilloscope probe
L
AC
AC
line
voltage
DC
C1
C2
Load
10µF
100nF
N
25.4mm
25.4mm
Page 2 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
10W AC-DC Power-Supply PAC10C
Page 3 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
10W AC-DC Power-Supply PAC10C
PAC10C
L
+Vout
-Vout
N
PE
This connection is not supported for the PAC10C
Typical application circuit
Figure 1a, single output
L
F1
PAC10CxxS
R1
L
ϑ
U
N
C1
C2
D1 +Vout
+Vo
R2
N
-Vout
-Vo
PE
PE
Figure 1b, ± dual output
L
F1
PAC10CxxD
R1
L
ϑ
U
N
R2
+Vo
C1a
C2a
D1a +Vout
Com
Com
N
PE
PE
-Vout
-Vo
C1b
C2b
D1b
C1
C2a
D1a +Vout 1
Figure 1c, isolated dual output
L
F1
PAC10CxxDI
R1
L
ϑ
N
U
-Vout 1
-Vo1
R2
N
PE
PE
+Vo1
+Vo2
+Vout 2
-Vo2
C7
C2b
D1b
-Vout 2
Page 4 of 6
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
10W AC-DC Power-Supply PAC10C
Application circuit and example for ripple and noise reduction
Figure 2
L
Rs
F1
PAC10C
L1
PIF001A
L
Cy
Cy
V
Cy
U
Cx
+V out
Rd
+V out
Cy
PE
C1
C2
D1
-V out
-V out
Rs
N
N
PE
PIF 001A is an integrated PHI-CON filter module which contains all components in the framed field of figure 2.
Table 1
C1
C2
C7
[µF]
F1
slow blow
fuse
R1
NTC
type
R2
MOV
type
D1
TVS
type
C4/5
Y type
[pF]
C6
X type
[nF]
[nF]
Single output
PAC10C03S
100
PAC10C05S
100
PAC10C09S
100
PAC10C12S
100
PAC10C15S
100
PAC10C24S
100
± Dual output
PAC10C05D
100
PAC10C12D
100
PAC10C15D
100
PAC10C24D
100
Dual output isolated
PAC10C0505DI
100
PAC10C0512DI
100
PAC10C0515DI
100
PAC10C0524DI
100
[µF]
[mH]
330
330
120
120
120
68
-
2A / 250V~
2A / 250V~
2A / 250V~
2A / 250V~
2A / 250V~
2A / 250V~
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
471KD14
471KD14
471KD14
471KD14
471KD14
471KD14
P6KE6.8A
P6KE6.8A
P6KE12A
P6KE20A
P6KE20A
P6KE30A
2200
2200
2200
2200
2200
2200
100
100
100
100
100
100
10..30
10..30
10..30
10..30
10..30
10..30
220
120
47
33
-
2A / 250V~
2A / 250V~
2A / 250V~
2A / 250V~
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
471KD14
471KD14
471KD14
471KD14
P6KE6.8A
P6KE6.8A
P6KE6.8A
P6KE6.8A
2200
2200
2200
2200
100
100
100
100
10..30
10..30
10..30
10..30
220
220
220
220
68
68
47
47
2A / 250V~
2A / 250V~
2A / 250V~
2A / 250V~
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
471KD14
471KD14
471KD14
471KD14
P6KE6.8A
P6KE6.8A
P6KE6.8A
P6KE6.8A
2200
2200
2200
2200
100
100
100
100
10..30
10..30
10..30
10..30
Model
L1
Note:
1. Output filtering capacitor C2 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic
capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be
80% or above. C1 is a ceramic capacitor, it is used to filter high frequency noise. TVS D1 is a recommended component to protect
post-circuits (if converter fails).
2. The varistor R2 protect the device under surge.
3. Recommended fuse parameter for F1 are 2 A / 250 V slow blow.
A external input NTC limited the inrush current. Recommended model is NTC 5D-9. (see figure 1 and R1 table 1)
4. If common requirement to EMC performance (EN55011 Class A), refer to figure 1.
If higher requirement to EMC performance (EN55011 Class B), refer to figure 2.
C6: X capacitor, recommended values 0.1 μF / 275 V;
C4, C5: Y capacitor, recommended values 2200 pF / 400 V;
L1: common mode choke, recommended inductance is about 10 mH – 30 mH.
Page 5 of 6
10W AC-DC Power-Supply PAC10C
EMC application circuit recommended PCB Layout
Safety and recommend wiring, line width A >3mm, space B > 6 mm, space C > 9 mm
Dimensions
Pin connection
Note:
Unit: mm
Pin diameter tolerance: ± 0.1 mm
Pin length: >6 mm
General tolerances: ± 0.5 mm
Pin
1
2
3
4
5
6
7
8
Pin configuration
Single
Dual
PE
N
L
- V out
omitted
omitted
omitted
+ V out
PE
N
L
- V out
omitted
common
omitted
+ V out
Dual
isolated
PE
N
L
- V out 1
+ V out 1
omitted
- V out 2
+ V out 2
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to