10W DC-DC Converter P10F-Series ● ● ● ● ● ● ● ● ● ● ● Wide 4:1 Input Range 1600 VDC Isolation MTBF >1 MHours Continuous Short Circuit Protection Over Load Protection Over Voltage Protection Efficiency up to 88% 15 mA no load Input Current Wide Operation Temperature Range -40...85°C On / Off Remote Control Input Soft Start Model selection guide Typ Single output P10F243R3S P10F2405S P10F2412S P10F2415S P10F483R3S P10F4805S P10F4812S P10F4815S Dual output P10F2405D P10F2412D P10F2415D P10F4805D P10F4812D P10F4815D Input voltage range [VDC] Input current no load full load [mA] [mA] Output voltage Output current Efficiency typ. [VDC] [mA] [%] Capacitor load max. [µF] 9...36 9...36 9...36 9...36 18...75 18...75 18...75 18...75 15 15 15 15 15 15 15 15 440 480 475 475 225 240 240 240 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 2700 2000 833 667 2700 2000 833 667 85 87 88 88 84 87 87 87 1200 1200 270 180 1200 1200 270 180 9...36 9...36 9...36 18...75 18...75 18...75 15 15 15 15 15 15 495 480 480 250 240 240 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±1000 ±420 ±330 ±1000 ±420 ±330 85 87 87 85 88 88 2 x 820 2 x 120 2 x 100 2 x 820 2 x 120 2 x 100 Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W DC-DC Converter P10F-Series Specifications Input Filter Pi Network Start up time with R-load 20 ms typ. Remote CTRL on/off, Pin1 On: 3...12 V or open input Off: 0...1.2 V Standby current 5mA typ Isolation: Rated voltage (for 60 s) 1600 VDC (flash tested 3s) Resistance 109 Ω Capacitance 1500 pF, typ. Output Voltage accuracy ± 1.2%, max. Voltage balance ± 1% (dual outputs) Temperature coefficient ± 0.02% / °C Ripple and noise 85 mVp-p, max. (at 20 MHz BW) Short circuit protection Indefinite (hiccup), Automatic restart Over load protection 170 % of Iout max. Over voltage protection 2.5 V, 3.3 V out type 3.9 V Z-diode clamping (±) 5.0 V out type 6.2 V Z-diode clamping (±) 12 V out type (±)15 V Z-diode clamping (±) 15 V out type (±)18 V Z-diode clamping Line voltage regulation ± 0.2 %, max. single ± 0.5%, max. Load regulation 0...100% load dual ± 1%, max. Cross regulation @ dual output ± 5 % Transient recovery time 250 µs typ. 3% Transient response drift @ 75%...50%...25% load General Switching frequency Safety Standard Reliability calculated MTBF (MIL-HDBK-217F) EMC Characteristics Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Humidity 270 kHz IEC 60950-1:2001 >1 Mhours @ 25°C EN55022 class A EN55022 class A EN61000-4-2 Crit. B EN61000-4-3 Crit. A EN61000-4-4 Crit. B EN61000-4-5 Crit. B EN61000-4-6 Crit. A EN61000-4-8 Crit. A -40 °C to +85 °C See derating curve 105 °C max. -40 °C to +125 °C Up to 95 %, non-condensing Free-air convection Cooling Physical Dimensions Weight Case material 31.75 x 20.32 x 10.16 mm 18 g Nickel-coated copper metal Epoxy (UL94V-0 rated) Potting material Absolute maximum ratings Pin soldering temperature 260°C for 10sec 1.5mm distance from body Input peak voltage for 0.1s -0.7 VDC …50 VDC @ 24 V type -0.7 VDC …100 VDC @ 48 V type 12µH, LD1-120-R Coiltronics + INPUT 22 / 23 14 + OUTPUT Remote ON 330µF KR-Series Nippon Chemicon 1 maximum C-Load see table DC/DC Converter Remote OFF 2/3 16 - INPUT - OUTPUT Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 10W DC-DC Converter P10F-Series Efficiency vs load Dimensions Pin connections Pin 1 2 3 9 11 14 16 22 23 Single Remote contr. -V Input -V Input Omitted N.C. +V Output -V Output +V Input +V Input Dual Remote contr. -V Input -V Input Common -V Output +V Output Common +V Input +V Input Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 2.10 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]