12W DC-DC Converter P12D-Series
●
●
●
●
●
●
●
●
●
●
●
Wide 4:1 Input Range
1600 VDC Isolation
MTBF >1 MHours
Continuous Short Circuit Protection
Over Load Protection
Over Voltage Protection
Efficiency up to 90%
15 mA no load Input Current
Wide Operation Temperature Range -40...85°C
On / Off Remote Control Input
Soft Start
Model selection guide
Typ
Input voltage
range
[VDC]
Input current
no load
[mA]
Output voltage Output current
Efficiency typ.
full load
[mA]
[VDC]
[mA]
[%]
Capacitor
Load
[µF]
Single output
P12D243R3S
P12D245R1S
P12D2412S
P12D2415S
P12D483R3S
P12D485R1S
P12D4812S
P12D4815S
9...36
9...36
9...36
9...36
18...75
18...75
18...75
18...75
15
15
15
15
15
15
15
15
575
580
575
575
285
290
285
290
3.3
5.1
12.0
15.0
3.3
5.1
12.0
15.0
3500
2400
1000
800
3500
2400
1000
800
87
89
90
90
88
89
88
89
2000
2000
430
300
2000
2000
430
300
9...36
9...36
9...36
18...75
18...75
18...75
15
15
15
15
15
15
562
575
562
300
295
290
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
±1200
±500
±400
±1200
±500
±400
87
90
90
87
90
90
2 x 1200
2 x 200
2 x 120
2 x 1200
2 x 200
2 x 120
Dual output
P12D2405D
P12D2412D
P12D2415D
P12D4805D
P12D4812D
P12D4815D
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12D-Series
Specifications
Input
Filter
Pi Network
Start up time with R-load
20 ms typ.
Remote CTRL on/off, Pin1 On: 3...12 V or open input
Off: 0...1.2 V
Standby current 5mA typ
Isolation:
Rated voltage (for 60 s)
1600 VDC (flash tested 3s)
Resistance
109 Ω
Capacitance
1500 pF, typ.
Output
Voltage accuracy
± 1.2%, max.
Voltage balance
± 1%
(dual outputs)
Temperature coefficient
± 0.02% / °C
Ripple and noise
85 mVp-p, max.
(at 20 MHz BW)
Short circuit protection
Indefinite (hiccup),
Automatic restart
Over load protection
170 % of Iout max.
Over voltage protection
2.5 V, 3.3 V out type 3.9 V Z-diode clamping
(±) 5.1 V out type 6.2 V Z-diode clamping
(±) 12 V out type (±)15 V Z-diode clamping
(±) 15 V out type (±)18 V Z-diode clamping
Line voltage regulation
± 0.2 %, max.
single ± 0.5%, max.
Load regulation
0...100% load
dual ± 1%, max.
Cross regulation @ dual output ± 5 %
Transient recovery time
250 µs typ.
3%
Transient response drift
@ 75%...50%...25% load
General
Switching frequency
Safety Standard
Reliability calculated
MTBF (MIL-HDBK-217F)
EMC Characteristics
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Humidity
Cooling
Physical
Dimensions
Weight
Case material
270 kHz
IEC 60950-1:2001
>1 Mhours @ 25°C
EN55022 class A
EN55022 class A
EN61000-4-2 Crit. B
EN61000-4-3 Crit. A
EN61000-4-4 Crit. B
EN61000-4-5 Crit. B
EN61000-4-6 Crit. A
EN61000-4-8 Crit. A
-40 °C to +85 °C
See derating curve
105 °C max.
-40 °C to +125 °C
Up to 95 %,
non-condensing
Free-air convection
31.75 x 20.32 x 10.16 mm
18 g
Nickel-coated copper
metal
Epoxy (UL94V-0 rated)
Potting material
Absolute maximum
ratings
Pin soldering temperature 260°C for 10sec
1.5mm distance from body
Input peak voltage for 0.1s -0.7 VDC …50 VDC @ 24 V type
-0.7 VDC …100 VDC @ 48 V type
12µH, LD1-120-R
Coiltronics
+ INPUT
22 / 23
14
+ OUTPUT
Remote ON
330µF KR-Series
Nippon Chemicon
1
DC/DC Converter
C-Load
see table
Remote OFF
2/3
16
- INPUT
- OUTPUT
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12D-Series
Efficiency vs Load
Dimensions
Pin connections
Pin
1
2
3
9
11
14
16
22
23
Single
Remote contr.
-V Input
-V Input
Omitted
N.C.
+V Output
-V Output
+V Input
+V Input
Dual
Remote contr.
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Life Support Policy: HY-LINE does not authorize the use of any of its products
for use in life support devices or systems without the express written approval
of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 02.10 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]