8W DC-DC Converter P8A-Series ● ● ● ● ● Wide 2:1 Input Range 1500 VDC Isolation Continuous Short Circuit Protection Efficiency up to 85 % Wide Operation Temperature Range -40...85 °C Model selection guide Type Single output P8A123R3S P8A1205S P8A1212S P8A1215S P8A243R3S P8A2405S P8A2412S P8A2415S P8A483R3S P8A4805S P8A4812S P8A4815S Dual output P8A1205D P8A1212D P8A1215D P8A2405D P8A2412D P8A2415D P8A4805D P8A4812D P8A4815D Input voltage Input current range without load at full load Output voltage Output current Efficiency typ. [VDC] [mA] [mA] [VDC] [mA] [%] Capacitor Load max. (see note 3) [µF] 9...18 9...18 9...18 9...18 18...36 18...36 18...36 18...36 36...72 36...72 36...72 36...72 20 20 20 20 15 15 15 15 15 15 15 15 687 762 784 803 344 381 392 397 172 191 198 198 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 2000 1500 665 535 2000 1500 665 535 2000 1500 665 535 80 82 85 83 80 82 85 84 80 82 84 84 3300 2200 470 220 3300 2200 470 220 3300 2200 470 220 9...18 9...18 9...18 18...36 18...36 18...36 36...72 36...72 36...72 20 20 20 15 15 15 15 15 15 813 794 794 407 402 392 203 196 196 ± 5.0 ± 12.0 ± 15.0 ± 5.0 ± 12.0 ± 15.0 ± 5.0 ± 12.0 ± 15.0 ±800 ±335 ±265 ±800 ±335 ±265 ±800 ±335 ±265 82 84 84 82 83 85 82 85 85 2 x 1000 2 x 220 2 x 100 2 x 1000 2 x 220 2 x 100 2 x 1000 2 x 220 2 x 100 Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 8W DC-DC Converter P8A-Series Specifications Input Voltage range Filter Reflected ripple input current Isolation: Isolation input to output Isolation input or output to case Resistance input to output Capacitance Output Voltage accuracy Voltage balance (dual outputs) Ripple and noise (at 20 MHz BW) Short circuit protection Over current limiting Line voltage regulation Load voltage regulation Load change 0…100% Temperature coefficient General Switching frequency Safety standard in accordance to Reliability calc. MTBF (MIL-HDBK-217 F) Environmental Radiated Emissions Conducted Emissions (see note 7) ESD RS EFT (see note 8) Surge (see note 8) CS PFMF Operating ambient temperature Case temperature Storage temperature Derating Humidity 12 VDC, 9…18 VDC 24 VDC, 18…36 VDC 48 VDC, 36…72 VDC Pi Network 35 mA p-p (see note 4) 1500 VDC (3s tested) 1000 VDC (3s tested) 9 10 Ω 1000 pF, typ. ± 1 %, max. ± 5 % (see note 1) 75 mVp-p, max. (see note 2) EN55022 CLASS A EN55022 CLASS A Cooling Physical Dimensions Weight Case material Potting material Absolute maximum ratings Max. input voltage < 100 ms 12 V input version 24 V input version 48 V input version Lead soldering temperature Continuous, Automatic restart 150% of Iout max. ± 0.5 %, max. Single out: ± 0.5 %, max. Dual out: ± 1 %, max. 3.3 V out: ± 1.5 %, max. ± 0.02 % / °C 330 kHz IEC 60950 910000 hours EN61000-4-2 Perf. Crit. A EN61000-4-3 Perf. Crit. A EN61000-4-4 Perf. Crit. A EN61000-4-5 Perf. Crit. A EN61000-4-6 Perf. Crit. A EN61000-4-7 Perf. Crit. A -40 °C to +60 °C -40 °C to +85 °C with derating 100 °C max. -40 °C to +125 °C None required Up to 95%, non-condensing Free-air convection 31.75 x 20.32 x 10.16 mm 17 g Nickel coated copper Epoxy (UL94V-0 rated) -0.7…25 V -0.7…50 V -0.7…100 V 260°C max. 10s, distance from package 1.5 mm L +Vin +Vout 12 µH C1 C2 DC/DC Converter Load 100 µF 100 V -Vin -Vout Note: 1. One load is 25 % to 100 % load. The other load is 100 %. The output voltage drift ± 5 % maximum. 2. Ripple & Noise measured with 1 µF ceramic capacitor C2. 3. Test by nominal input voltage and constant resistor load. 4. Measured input reflected ripple current with a simulated source inductance of 12 µH. 5. Operation under no-load and 10 % conditions will not damage these devices, however they may not meet all listed specifications. 6. It’s necessary to add minimum capacitor in output for some models, please check single model datasheet for detail value. 7. Input filter components (C1, L) are used to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module. All leads should be minimized to decrease radiated noise. 8. An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. Suggested filter capacitor: Nippon - Chemicon KY series, 220 µF / 100 V. 9. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating. Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 8W DC-DC Converter P8A-Series Dimensions Pin connections Pin 2 3 9 11 14 16 22 23 Standard Single Dual -V Input -V Input -V Input -V Input Omitted Common N.C. -V Output +V Output +V Output -V Output Common +V Input +V Input +V Input +V Input PHI-CON is a trademark of HY-LINE power components. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 10.13 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]