Download

8W DC-DC Converter P8A-Series
●
●
●
●
●
Wide 2:1 Input Range
1500 VDC Isolation
Continuous Short Circuit Protection
Efficiency up to 85 %
Wide Operation Temperature Range -40...85 °C
Model selection guide
Type
Single output
P8A123R3S
P8A1205S
P8A1212S
P8A1215S
P8A243R3S
P8A2405S
P8A2412S
P8A2415S
P8A483R3S
P8A4805S
P8A4812S
P8A4815S
Dual output
P8A1205D
P8A1212D
P8A1215D
P8A2405D
P8A2412D
P8A2415D
P8A4805D
P8A4812D
P8A4815D
Input voltage
Input current
range
without load
at full load
Output
voltage
Output
current
Efficiency
typ.
[VDC]
[mA]
[mA]
[VDC]
[mA]
[%]
Capacitor
Load max.
(see note 3)
[µF]
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
20
20
20
20
15
15
15
15
15
15
15
15
687
762
784
803
344
381
392
397
172
191
198
198
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
2000
1500
665
535
2000
1500
665
535
2000
1500
665
535
80
82
85
83
80
82
85
84
80
82
84
84
3300
2200
470
220
3300
2200
470
220
3300
2200
470
220
9...18
9...18
9...18
18...36
18...36
18...36
36...72
36...72
36...72
20
20
20
15
15
15
15
15
15
813
794
794
407
402
392
203
196
196
± 5.0
± 12.0
± 15.0
± 5.0
± 12.0
± 15.0
± 5.0
± 12.0
± 15.0
±800
±335
±265
±800
±335
±265
±800
±335
±265
82
84
84
82
83
85
82
85
85
2 x 1000
2 x 220
2 x 100
2 x 1000
2 x 220
2 x 100
2 x 1000
2 x 220
2 x 100
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
8W DC-DC Converter P8A-Series
Specifications
Input
Voltage range
Filter
Reflected ripple input current
Isolation:
Isolation input to output
Isolation input or output to case
Resistance input to output
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Over current limiting
Line voltage regulation
Load voltage regulation
Load change 0…100%
Temperature coefficient
General
Switching frequency
Safety standard in
accordance to
Reliability calc. MTBF
(MIL-HDBK-217 F)
Environmental
Radiated Emissions
Conducted Emissions
(see note 7)
ESD
RS
EFT (see note 8)
Surge (see note 8)
CS
PFMF
Operating ambient
temperature
Case temperature
Storage temperature
Derating
Humidity
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
35 mA p-p (see note 4)
1500 VDC (3s tested)
1000 VDC (3s tested)
9
10 Ω
1000 pF, typ.
± 1 %, max.
± 5 % (see note 1)
75 mVp-p, max. (see note 2)
EN55022 CLASS A
EN55022 CLASS A
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Absolute maximum ratings
Max. input voltage < 100 ms
12 V input version
24 V input version
48 V input version
Lead soldering temperature
Continuous,
Automatic restart
150% of Iout max.
± 0.5 %, max.
Single out: ± 0.5 %, max.
Dual out: ± 1 %, max.
3.3 V out: ± 1.5 %, max.
± 0.02 % / °C
330 kHz
IEC 60950
910000 hours
EN61000-4-2 Perf. Crit. A
EN61000-4-3 Perf. Crit. A
EN61000-4-4 Perf. Crit. A
EN61000-4-5 Perf. Crit. A
EN61000-4-6 Perf. Crit. A
EN61000-4-7 Perf. Crit. A
-40 °C to +60 °C
-40 °C to +85 °C with derating
100 °C max.
-40 °C to +125 °C
None required
Up to 95%,
non-condensing
Free-air convection
31.75 x 20.32 x 10.16 mm
17 g
Nickel coated copper
Epoxy (UL94V-0 rated)
-0.7…25 V
-0.7…50 V
-0.7…100 V
260°C max. 10s, distance
from package 1.5 mm
L
+Vin
+Vout
12 µH
C1
C2
DC/DC Converter
Load
100 µF
100 V
-Vin
-Vout
Note:
1. One load is 25 % to 100 % load. The other load is 100 %. The output voltage drift ± 5 % maximum.
2. Ripple & Noise measured with 1 µF ceramic capacitor C2.
3. Test by nominal input voltage and constant resistor load.
4. Measured input reflected ripple current with a simulated source inductance of 12 µH.
5. Operation under no-load and 10 % conditions will not damage these devices, however they may not meet all listed
specifications.
6. It’s necessary to add minimum capacitor in output for some models, please check single model datasheet for detail
value.
7. Input filter components (C1, L) are used to help meet conducted emissions requirement for the module.
These components should be mounted as close as possible to the module. All leads should be minimized to
decrease radiated noise.
8. An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
Suggested filter capacitor: Nippon - Chemicon KY series, 220 µF / 100 V.
9. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating.
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
8W DC-DC Converter P8A-Series
Dimensions
Pin connections
Pin
2
3
9
11
14
16
22
23
Standard
Single
Dual
-V Input
-V Input
-V Input
-V Input
Omitted
Common
N.C.
-V Output
+V Output
+V Output
-V Output
Common
+V Input
+V Input
+V Input
+V Input
PHI-CON is a trademark of HY-LINE power components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 10.13 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]