3W DC-DC Converter P3M-Series
●
●
●
●
●
●
●
Wide 2:1 input range
Flat case profile 7 mm
Continuous short circuit protection
Over Voltage protection
Soft start function
No internal tantalum capacitors
Efficiency up to 88 %
Model selection guide
Type
Input
voltage
range
[VDC]
Single output
P3M0505S
4.5…9
P3M0512S
4.5…9
P3M0515S
4.5…9
P3M1205S
9...18
P3M1212S
9...18
P3M1215S
9...18
P3M2405S
18...36
P3M2412S
18...36
P3M2415S
18...36
P3M4805S
36...75
P3M4812S
36...75
P3M4815S
36...75
Dual output
P3M0512D
4.5…9
P3M0515D
4.5…9
P3M1212D
9...18
P3M1215D
9...18
P3M2412D
18...36
P3M2415D
18...36
P3M4812D
36...75
P3M4815D
36...75
Input current
no
full
load
load
[mA]
[mA]
Output
voltage
50
50
50
25
25
25
15
15
15
10
10
10
896
857
857
357
338
338
176
167
167
90
82
82
5.0
12.0
15.0
5.0
12.0
15.0
5.0
12.0
15.0
5.0
12.0
15.0
0
0
0
0
0
0
0
0
0
0
0
0
600
250
200
600
250
200
600
250
200
600
250
200
67
70
70
70
74
74
71
75
75
71
76
76
100
100
100
100
100
100
220
220
220
220
220
220
50
50
25
25
15
15
10
10
780
750
317
301
159
151
79
76
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
0
0
0
0
0
0
0
0
±130
±100
±130
±100
±130
±100
±130
±100
82
82
84
85
84
85
84
84
2 x 220
2 x 100
2 x 220
2 x 100
2 x 220
2 x 100
2 x 220
2 x 100
[VDC]
Output current
min.
[mA]
max.
[mA]
Efficiency Capacitance
typ.
load max.
(see note 3)
[%]
[µF]
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3M-Series
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3M-Series
Specifications
Input
Filter
Pi network
Start up time @ min. Vin and 20 ms, max.
constant resistive load
Reflected ripple current
20 mAp-p (see note 5)
Output
Voltage accuracy
±1%
Voltage balance (dual outputs)
±1%
Ripple and noise (at 20 MHz BW)
75 mVp-p, max. (see note 2)
Short circuit protection
Continuous
Short circuit restart
Automatic
Overcurrent protection
185 % typ, of full load
Line regulation
± 0.5 %, max.
Load regulation (@ 0...100 % load) ± 1 %, max. @ balanced load
Cross regulation (dual output) ± 5 %, max. (see note 1)
Temperature coefficient
± 0.02 % / °C
Transient response deviation ± 3 %, max. (see note 4)
Over voltage protection
5 V output type
6.2 V, z-diode clamp voltage
12 V output type
15 V, z-diode clamp voltage
15 V output type
18 V, z-diode clamp voltage
± 12 V output type
± 15 V, z-diode clamp voltage
± 15 V output type
± 18 V, z-diode clamp voltage
Physical
Dimensions
35 x 23 x 7 mm
Weight
16 g, max.
Isolation
Rated voltage input to output,
input or output to case
Resistance
Capacitance input / output
General
Safety standard (designet to
meet)
Reliability calculated MTBF
(Mil –HDBK-217 F)
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Absolute maximum ratings
5 V input types
12 V input types
24 V input types
48 V input types
Soldering temperature
1.5 mm distance from case
500 VAC
6
50 Ω min. @ 500 V
500 pF, max.
IEC / EN60950-1
> 1.6 Mio. hours
100 kHz
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 95%, non condensing
Free-air convection
Input voltage, 100 ms, max.
-0.7…15 VDC
-0.7…25 VDC
-0.7…50 VDC
-0.7…100 VDC
260 °C, 10 s max.
Note:
1. One load is 25 % to 100 % load, the other load is 100 % load, the output voltage variable rate is within ±5 %.
2. Typical value at nominal input voltage and full load,measured by 20 MHz oscilloscope.
3. Test by nominal input voltage and constant resistive load.
4. Tested by normal Vin and 50 % load step change ( 100 % … 50 % of full output current, 50 % … 0 % of full output current ).
5. Measured Input reflected ripple current with a simulated source inductance of 12 µH.
6. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating.
Dimensions
Pin connections
Pin
1
2
3
4
5
Single
-V Input
+V Input
+V Output
Omitted
-V Output
Dual
-V Input
+V Input
+V Output
Common
-V Output
Notes :
All dimensions are typical in millimeters.
1. Pin diameter: 1.0 ±0.05
2. Pin pitch tolerance: ±0.35
3. Case Tolerance: ±0.5
4. The converter metal case is in contact with the cleaning stand of on the PCB.
To keep isolation, an adequate PCB layout on the mounted side is required.
PHI-CON is a trademark of HY-LINE power components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 01.14 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]