3W DC-DC Converter P3M-Series ● ● ● ● ● ● ● Wide 2:1 input range Flat case profile 7 mm Continuous short circuit protection Over Voltage protection Soft start function No internal tantalum capacitors Efficiency up to 88 % Model selection guide Type Input voltage range [VDC] Single output P3M0505S 4.5…9 P3M0512S 4.5…9 P3M0515S 4.5…9 P3M1205S 9...18 P3M1212S 9...18 P3M1215S 9...18 P3M2405S 18...36 P3M2412S 18...36 P3M2415S 18...36 P3M4805S 36...75 P3M4812S 36...75 P3M4815S 36...75 Dual output P3M0512D 4.5…9 P3M0515D 4.5…9 P3M1212D 9...18 P3M1215D 9...18 P3M2412D 18...36 P3M2415D 18...36 P3M4812D 36...75 P3M4815D 36...75 Input current no full load load [mA] [mA] Output voltage 50 50 50 25 25 25 15 15 15 10 10 10 896 857 857 357 338 338 176 167 167 90 82 82 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 0 0 0 0 0 0 0 0 0 0 0 0 600 250 200 600 250 200 600 250 200 600 250 200 67 70 70 70 74 74 71 75 75 71 76 76 100 100 100 100 100 100 220 220 220 220 220 220 50 50 25 25 15 15 10 10 780 750 317 301 159 151 79 76 ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 0 0 0 0 0 0 0 0 ±130 ±100 ±130 ±100 ±130 ±100 ±130 ±100 82 82 84 85 84 85 84 84 2 x 220 2 x 100 2 x 220 2 x 100 2 x 220 2 x 100 2 x 220 2 x 100 [VDC] Output current min. [mA] max. [mA] Efficiency Capacitance typ. load max. (see note 3) [%] [µF] Page 1 of 2 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 3W DC-DC Converter P3M-Series Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 3W DC-DC Converter P3M-Series Specifications Input Filter Pi network Start up time @ min. Vin and 20 ms, max. constant resistive load Reflected ripple current 20 mAp-p (see note 5) Output Voltage accuracy ±1% Voltage balance (dual outputs) ±1% Ripple and noise (at 20 MHz BW) 75 mVp-p, max. (see note 2) Short circuit protection Continuous Short circuit restart Automatic Overcurrent protection 185 % typ, of full load Line regulation ± 0.5 %, max. Load regulation (@ 0...100 % load) ± 1 %, max. @ balanced load Cross regulation (dual output) ± 5 %, max. (see note 1) Temperature coefficient ± 0.02 % / °C Transient response deviation ± 3 %, max. (see note 4) Over voltage protection 5 V output type 6.2 V, z-diode clamp voltage 12 V output type 15 V, z-diode clamp voltage 15 V output type 18 V, z-diode clamp voltage ± 12 V output type ± 15 V, z-diode clamp voltage ± 15 V output type ± 18 V, z-diode clamp voltage Physical Dimensions 35 x 23 x 7 mm Weight 16 g, max. Isolation Rated voltage input to output, input or output to case Resistance Capacitance input / output General Safety standard (designet to meet) Reliability calculated MTBF (Mil –HDBK-217 F) Switching frequency Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Absolute maximum ratings 5 V input types 12 V input types 24 V input types 48 V input types Soldering temperature 1.5 mm distance from case 500 VAC 6 50 Ω min. @ 500 V 500 pF, max. IEC / EN60950-1 > 1.6 Mio. hours 100 kHz -40 °C to +85 °C 100 °C max. -40 °C to +125 °C None required Up to 95%, non condensing Free-air convection Input voltage, 100 ms, max. -0.7…15 VDC -0.7…25 VDC -0.7…50 VDC -0.7…100 VDC 260 °C, 10 s max. Note: 1. One load is 25 % to 100 % load, the other load is 100 % load, the output voltage variable rate is within ±5 %. 2. Typical value at nominal input voltage and full load,measured by 20 MHz oscilloscope. 3. Test by nominal input voltage and constant resistive load. 4. Tested by normal Vin and 50 % load step change ( 100 % … 50 % of full output current, 50 % … 0 % of full output current ). 5. Measured Input reflected ripple current with a simulated source inductance of 12 µH. 6. Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating. Dimensions Pin connections Pin 1 2 3 4 5 Single -V Input +V Input +V Output Omitted -V Output Dual -V Input +V Input +V Output Common -V Output Notes : All dimensions are typical in millimeters. 1. Pin diameter: 1.0 ±0.05 2. Pin pitch tolerance: ±0.35 3. Case Tolerance: ±0.5 4. The converter metal case is in contact with the cleaning stand of on the PCB. To keep isolation, an adequate PCB layout on the mounted side is required. PHI-CON is a trademark of HY-LINE power components. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 01.14 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]