Express5800/E120g-M - April 25, 2016

NEC Express5800/E120g-M
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
April 25, 2016
Revision 1.0
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 7
Front and Rear Views for Server Module Enclosure ......................................................................... 7
Front and Rear Views for Server Module............................................................................................ 8
Dimensions (mm) .................................................................................................................................. 9
CONFIGURATION DIAGRAM ....................................................................................... 11
EXPANSION SLOT ........................................................................................................ 12
SERVER CONFIGURATION ......................................................................................... 13
1
Maximum Server Module Configuration with 1600 W PSU ..................................................... 13
1.1
Configuration (Up to 35° C ambient temp.) ....................................................................... 13
2 Maximum Server Module Configuration with 1000 W PSU ..................................................... 13
2.1
Configuration (Up to 40° C ambient temp.) ....................................................................... 13
2.2
Configuration (Up to 35° C ambient temp.) ....................................................................... 14
3 Server Module Enclosure ............................................................................................................ 15
3.1
Server Module Enclosure .................................................................................................. 15
3.2
Options for Server Module Enclosure ................................................................................ 15
4 Server Module .............................................................................................................................. 15
5 Processors and Heat Sink .......................................................................................................... 16
6 Memory ......................................................................................................................................... 17
7 Internal Hard Disk Drives ............................................................................................................ 19
7.1
RAID Configuration ............................................................................................................ 19
7.2
Internal Drive Configuration ............................................................................................... 19
7.3
Supported HDD/SDD ......................................................................................................... 22
8 2.5-inch PCIe SSD ........................................................................................................................ 24
8.1
2.5-inch PCIeSSD Installation Kit ...................................................................................... 24
8.2
PCIe SSD ........................................................................................................................... 25
9 Optical Drive ................................................................................................................................. 25
10 PCI Riser Card / PCI Card .......................................................................................................... 25
10.1 PCI Riser Card ................................................................................................................... 25
10.2 PCI Rear Bracket ............................................................................................................... 25
10.3 Network Interface Controller .............................................................................................. 25
10.4 InfiniBand ........................................................................................................................... 27
10.5 External Storage Controller ............................................................................................... 28
11 Other Add-in Components......................................................................................................... 29
11.1 Internal Flash Memory ....................................................................................................... 29
11.2 Flash FDD .......................................................................................................................... 29
11.3 Boot Mode Setup Option ................................................................................................... 29
12 Add-on Components .................................................................................................................. 30
12.1 17-inch LCD Console Drawer ............................................................................................ 30
12.2 KVM Switch ........................................................................................................................ 30
12.3 Server Management License ............................................................................................. 31
REFERENCES............................................................................................................... 32
Server Management ............................................................................................................................ 32
Endurance of SSD ............................................................................................................................... 33
NEC Corporation
Revision 1.0 – April, 2016
2
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
OS Support Matrix for PCI Cards and Embedded Controller ......................................................... 34
Supported PCI Cards and Installable Slots ...................................................................................... 35
Secure Boot Mode............................................................................................................................... 35
Tested Linux Operating Systems ...................................................................................................... 36
Copyright Notice and Liability Disclaimer ........................................................................................ 37
REVISION HISTORY ..................................................................................................... 38
Technical Specification
Key Features



High performance with the latest Intel® Xeon® processor E5-2600 v4 product family
Up to 1 TB of high speed DDR4 memory
Highly reliable with redundant fan
Specification
Server Module (1/2)
Model
E120g-M
Part Number
Processor
N8100-2385F, N8100-2386F
Intel® Xeon®
Intel® Xeon®
Intel® Xeon®
Intel® Xeon®
Processor
Processor
Processor
Processor
E5-2609 v4
E5-2620 v4
E5-2630 v4
E5-2640 v4
1.70 GHz
2.10 GHz
2.20 GHz
2.40 GHz
1 to 2
20 MB
25 MB
8C / 8T
8C / 16T
10C / 20T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1 TB (16 x 64 GB)
ECC, x4/x8 SDDC
0 GB
SAS HDD : 7.2 TB (4 x 1.8 TB)
SATA HDD : 8 TB (4 x 2 TB)
SAS SSD : 1.6 TB (4 x 400 GB)
SATA SSD : 6.4 TB (4 x 1.6 TB)
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
RAID 0/1/5/6/10 (Optional)
Supported
4
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x8 (x8 connector) for a dedicated PCI card
Integrated in Server Management Controller (32MB)
1
1600 x 1200 / 16.7M
1 VGA (15-pin mini D-sub, 1 front)
2 x USB3.0 (2 x front)
1 x USB2.0 (1 x internal)
1 Serial (9-pin mini D-sub, RS232-C, 1 rear)
4 1000BASE-T LAN connector (RJ-45, 4 rear)
1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Internal Storage
Type
Standard Capacity
Maximum Capacity
Memory protection
Standard Capacity
Maximum Capacity
Disk Controller
RAID
Hot Plug
Disk Drive Bays
Expansion Slots
Video
Interfaces
NEC Corporation
Controller (VRAM)
Resolution / Color
Revision 1.0 – April, 2016
3
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Model
E120g-M
Server Management
Redundant Fan
Power
(Max. Config, Idling)
Consumption
(Max. Config,
Operating)
Acoustic Noise
Max. Config, Idling
(Sound Pressure
Max. Config, Operating
2
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
EXPRESSSCOPE Engine 3
Standard, non-hot plug
123 Watt
124 Watt
121 Watt
121 Watt
426 Watt
450 Watt
470 Watt
Regulatory and Safety
Operating Systems
1
2
3
4
5
450 Watt
52.0dB
68.0dB
52.0dB
69.0dB
220.0 × 780.0 × 40.4 mm / 8.66 x 30.7 x 1.59 in
5 kg / 7 kg, 11.02 lbs. / 15.43 lbs.
3
3
Operating: 5° to 40° C / 41° to 104° F , 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, CE, UL, CB, BSMI, KC, RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
4
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
5
VMware ESXi™ 6.0 Update 1
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may
vary by the operating environment.
Maximum temperature depends on the server configuration. Refer to the Server Configuration for detail.
For Linux support, contact your sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
At least 5 GB of logical memory is required.
Server Module (2/2)
Model
Part Number
Processor
E120g-M
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Internal Storage
Type
Standard Capacity
Maximum Capacity
Memory protection
Standard Capacity
Maximum Capacity
Disk Controller
NEC Corporation
N8100-2385F, N8100-2386F
Intel® Xeon®
Intel® Xeon®
Processor
Processor
E5-2650 v4
E5-2650L v4
2.20 GHz
1.70 GHz
1 to 2
30 MB
35 MB
12C / 24T
14C / 28T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1 TB (16 x 64 GB)
ECC, x4/x8 SDDC
0 GB
SAS HDD : 7.2 TB (4 x 1.8 TB)
SATA HDD : 8 TB (4 x 2 TB)
SAS SSD : 1.6 TB (4 x 400 GB)
SATA SSD : 6.4 TB (4 x 1.6 TB)
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
Revision 1.0 – April, 2016
Intel® Xeon®
Processor
E5-2660 v4
2.00 GHz
4
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Model
Internal Storage
(Cont’d)
E120g-M
RAID
Hot Plug
Disk Drive Bays
Expansion Slots
Video
Controller (VRAM)
Resolution / Color
Interfaces
Server Management
Redundant Fan
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Max. Config, Idling
Max. Config, Operating
Acoustic Noise
(Sound Pressure
2
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety
Operating Systems
1
2
3
4
5
RAID 0/1/5/6/10 (Optional)
Supported
4
Total: 2 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x8 (x8 connector) for a dedicated PCI card
Integrated in Server Management Controller (32MB)
1
1600 x 1200 / 16.7M
1 VGA (15-pin mini D-sub, 1 front)
2 x USB3.0 (2 x front)
1 x USB2.0 (1 x internal)
1 Serial (9-pin mini D-sub, RS232-C, 1 rear)
4 1000BASE-T LAN connector (RJ-45, 4 rear)
1 1000BASE-T LAN connector for Management (RJ-45, 1 rear)
EXPRESSSCOPE Engine 3
Standard, non-hot plug
128 Watt
130 Watt
124 Watt
481 Watt
417 Watt
492 Watt
52.0dB
68.0dB
52.0dB
69.0dB
52.0dB
68.0dB
220.0 × 780.0 × 40.4 mm / 8.66 x 30.7 x 1.59 in
5 kg / 7 kg, 11.02 lbs. / 15.43 lbs.
3
3
Operating: 5° to 40° C / 41° to 104° F , 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, CE, UL, CB, BSMI, KC, RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
4
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
5
VMware ESXi™ 6.0 Update 1
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may
vary by the operating environment.
Maximum temperature depends on the server configuration. Refer to the Server Configuration for detail.
For Linux support, contact your sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
At least 5 GB of logical memory is required.
NEC Corporation
Revision 1.0 – April, 2016
5
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Server Module Enclosure
Model
Server Module Enclosure
Part Number
Server Module Bays
Power Supply Bays
Redundant Fan
Redundant Power Supply
Power Supply
N8141-77F
N8141-78F
4
2
Standard, hot plug
2 x 1,000 Watt 80 PLUS® Platinum
2 x 1,600 Watt 80 PLUS® Platinum
certified hot plug PSU
certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
100 VAC : 1,247 VA / 1,185 Watt
1,896 VA / 1,801 Watt
200 VAC : 1,416 VA / 1,345 Watt
100 VAC : 4,266 kJ/h
6,484 kJ/h
200 VAC : 4,842 kJ/h
447.0 x 781.2 x 86.8 mm / 17.6 x 30.76 x 3.42 in (2U)
13 kg / 43 kg, 28.66 lbs. / 94.80 lbs.
2
Operating: 5° to 40° C
Operating: 5° to 35° C
/ 41° to 104° F, 20 to 80%
/ 41° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C
Non-Operating: -10° to 55° C
/ 14° to 131° F, 20 to 80%
/ 14° to 131° F, 20 to 80%
RoHS
Maximum Power Consumption
Heat Dissipation
Dimensions (W x D x H )
1
Weight (Minimum / Maximum)
Temperature, Relative
Humidity (non-condensing)
Regulatory and Safety
1
2
The weight was measured with the following system configurations:
Minimum: Server Module Enclosure with two power supplies
Maximum : Server Module Enclosure with two power supplies and four server modules with maximum
configuration
Up to 35° C when configured with 64GB DIMM, or when a dual processor configuration with E5-2650L v4.
NEC Corporation
Revision 1.0 – April, 2016
6
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
External Views
Front and Rear Views for Server Module Enclosure
Front View
A
B
A
B
C
D
Legend
A.
B.
C.
D.
Module Slot #1
Module Slot #2
Module Slot #3
Module Slot #4
Rear View
B
E
A
D
F
C
Legend
A.
B.
C.
Module Slot #1
Module Slot #2
Module Slot #3
NEC Corporation
D.
E.
F.
Module Slot #4
Power Supply Slot #1
Power Supply Slot #2
Revision 1.0 – April, 2016
7
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Front and Rear Views for Server Module
Front View
A
B
C
D
F
EG H I J
Legend
A.
B.
C.
D.
E.
F.
G.
H
I.
J.
2.5-inch Drive Bays
Pull-out Tab
USB Connector
Power Button / Power LED
UID LED Button
Display Connector
Dump (NMI) Button
BMC Reset Button
System Status LED 1
System Status LED 2
Rear View
A
C
B
D
F
E
G
H
I
J
Legend
A.
B.
C.
D.
E.
PCI Slot2 (Low Profile)
PCI Slot1 (Dedicated Slot)
Serial Port Connector
Management LAN Connector
Data LAN Connector1
NEC Corporation
F.
G.
H.
I.
J.
UID Button / LED
Data LAN Connector2
Data LAN Connector3
Data LAN Connector4
Power LED
Revision 1.0 – April, 2016
8
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Dimensions (mm)
Server Module Enclosure
Server Module (Left)
NEC Corporation
Revision 1.0 – April, 2016
9
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Server Module (Right)
NEC Corporation
Revision 1.0 – April, 2016
10
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Configuration Diagram
Server Module Enclosure
Legend:
Standard components
Server Module (Left)
Legend:
NEC Corporation
Standard Components
Minimum required components
Revision 1.0 – April, 2016
11
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Server Module (Right)
Front
Rear
Top
Legend:
Standard Components
Minimum required components
Expansion Slot
Slot#1
Slot#2
Legend
#1
PCIe 3.0 x8, x8 connector, for a dedicated PCI card
#2
PCIe 3.0 x16, x16 connector, Low-profile, up to 167.6 mm length
NOTE:

N8116-36 PCIe x16 Riser Card Kit is required for the slot #2.
NEC Corporation
Revision 1.0 – April, 2016
12
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Server Configuration
1 Maximum Server Module Configuration with 1600 W PSU
See the table below for the maximum server configuration based on processor configuration, input voltage,
and maximum ambient temperature for N8141-78F Module Enclosure with 1600 Watt power supply.
The condition for the maximum server configuration is defined when four servers with the same
configuration are installed. For other server configurations, please consult your sales representative.
1.1
Configuration (Up to 35° C ambient temp.)
200VAC Input (with RAID controller, PCI riser [N8116-36] and PCI card)
Processor Type
E5-2609 v4
E5-2620 v4
E5-2650L v4
E5-2630 v4
E5-2640 v4
E5-2650 v4
E5-2660 v4
# of Processors
# of 64 GB
DIMMs
# of HDD
(SAS 600GB, 15000rpm)
No limitation
2
2
2
2
Up to 8 DIMMs
4 HDDs
16 DIMMs
Up to 2 HDDs
Up to 6 DIMMs
4 HDDs
16 DIMMs
Up to 2 HDDs
Up to 5 DIMMs
3 HDDs
16 DIMMs
Up to 8 DIMMs
Up to 1 HDD
Up to 1 HDD
2 Maximum Server Module Configuration with 1000 W PSU
See the table below for the maximum server configuration based on processor configuration, input voltage,
and maximum ambient temperature for N8141-77F Module Enclosure with 1000 Watt power supply.
The condition for the maximum server configuration is defined when four servers with the same
configuration are installed. For other server configurations, please consult your sales representative.
2.1
Configuration (Up to 40° C ambient temp.)
100VAC Input (with RAID controller, PCI riser [N8116-36] and PCI card)
Processor Type
E5-2609 v4
E5-2620 v4
E5-2630 v4
E5-2640 v4
E5-2650 v4
E5-2650L v4
E5-2660 v4
NEC Corporation
# of Processors
1
1
1
1
1
# of 32 GB
DIMMs
# of HDD
(SAS 600GB, 15000rpm)
Up to 7 DIMMs
Up to 8 DIMMs
Up to 5 DIMMs
Up to 3 HDDs
Up to 2 HDDs
Up to 2 HDDs
8 DIMMs
Up to 1 HDD
Up to 3 DIMMs
Up to 1 HDD
Up to 1 DIMM
Up to 1 HDD
Up to 3 DIMMs
Up to 3 HDDs
8 DIMMs
Up to 2 HDD
Not supported
Revision 1.0 – April, 2016
13
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
200VAC Input (with RAID controller, PCI riser [N8116-36] and PCI card)
Processor Type
E5-2609 v4
E5-2620 v4
E5-2630 v4
E5-2640 v4
E5-2650 v4
E5-2650L v4
E5-2660 v4
# of Processors
# of 32 GB
DIMMs
No limitation
1
1
# of HDD
(SAS 600GB, 15000rpm)
Up to 1 DIMM
8 DIMMs
Up to 4 HDDs
Up to 1 HDD
NOTE:

Up to 35° C ambient temperature when configured with 64GB DIMM
2.2
Configuration (Up to 35° C ambient temp.)
100VAC Input (with RAID controller, PCI riser [N8116-36] and PCI card)
Processor Type
E5-2609 v4
E5-2620 v4
E5-2630 v4
E5-2640 v4
E5-2650 v4
E5-2650L v4
# of Processors
# of 64 GB
DIMMs
# of HDD
(SAS 600GB, 15000rpm)
1
1
8 DIMMs
8 DIMMs
Up to 3 HDDs
Up to 1 HDD
1
Up to 4 DIMMs
Up to 1 HDD
1
Up to 1 DIMM
Up to 3 DIMMs
8 DIMMs
Up to 1 HDD
Up to 3 HDD
Up to 2 HDD
1
E5-2660 v4
Not supported
200VAC Input (with RAID controller, PCI riser [N8116-36] and PCI card)
Processor Type
E5-2609 v4
E5-2620 v4
E5-2630 v4
E5-2640 v4
E5-2650 v4
E5-2650L v4
E5-2660 v4
NEC Corporation
# of Processors
# of 64 GB
DIMMs
1
Revision 1.0 – April, 2016
# of HDD
(SAS 600GB, 15000rpm)
No limitation
14
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
3 Server Module Enclosure
3.1
Server Module Enclosure
Product Name / Description
Part Number
Module Enclosure
No server module, no PSU cable
Including: 1000 Watt power supply
For E120g-M
Module Enclosure
No server module, no PSU cable
Including: 1600 Watt power supply (200V only)
For E120g-M
N8141-77F
N8141-78F
NOTE:

Up to four server modules can be installed.
3.2
Options for Server Module Enclosure
3.2.1
Blank Panel
Product Name / Description
Part Number
Blank Panel
1pc of filler panel for server module slots
N8141-61F
NOTE:

The blank panels must be installed into the vacant server module slots.
4 Server Module
Product Name / Description
Part Number
NEC Express5800/E120g-M
Server Module(Left)
No processor, no RAM, no HDD, no ODD
NEC Express5800/E120g-M
Server Module(Right)
No processor, no RAM, no HDD, no ODD
N8100-2385F
N8100-2386F
NOTE:

The base model must be ordered with a processor kit and a memory kit.

The server module for left must be installed into slot #1 and #3, and that for right must be installed into
slot #2 and #4.

The server modules must be installed in an order from server module slot #1.

E120g-M server modules cannot be installed in N8141-62F/-65F/-66F module enclosure.
NEC Corporation
Revision 1.0 – April, 2016
15
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
5 Processors and Heat Sink
Available sockets: 2
Category
Product Name / Description
Part Number
Processors
1 Processor
Required
Xeon E5-2609 v4 Processor Kit
Intel® Xeon ® Processor E5-2609 v4 (1.70 GHz, 8C/8T, 20 MB)
Xeon E5-2620 v4 Processor Kit
Intel® Xeon ® Processor E5-2620 v4 (2.10 GHz, 8C/16T, 20 MB)
Xeon E5-2630 v4 Processor Kit
Intel® Xeon ® Processor E5-2630 v4 (2.20 GHz, 10C/20T, 25 MB)
Xeon E5-2640 v4 Processor Kit
Intel® Xeon ® Processor E5-2640 v4 (2.40 GHz, 10C/20T, 25 MB)
Xeon E5-2650 v4 Processor Kit
Intel® Xeon ® Processor E5-2650 v4 (2.20 GHz, 12C/24T, 30 MB)
Xeon E5-2650L v4 Processor Kit
Intel® Xeon ® Processor E5-2650L v4(1.70 GHz,14C/28T, 35 MB)
Xeon E5-2660 v4 Processor Kit
Intel® Xeon ® Processor E5-2660 v4 (2.00 GHz, 14C/28T, 35 MB)
Processor Heat Sink
For 1st Processor
N8101-974F
Processor Heat Sink
For 2nd Processor
N8101-1049F
Heat Sink
1st
2nd
N8101-975F
N8101-976F
N8101-977F
N8101-978F
N8101-979F
N8101-980F
(Standard)
NOTE:

One processor kit from above must be installed.

The processors must be the same to configure dual processor system.

Up to 35° C ambient temperature when a dual processor configuration with E5-2650L v4.
The maximum number of logical processors supported by OS
See the table below for the maximum number of logical processors that you can actually use on your
system.
Number of Logical Processors Supported by Operating Systems
Microsoft Windows Server 2008 R2 Standard (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
Microsoft Windows Server 2012 R2 Standard
Microsoft Windows Server 2012 R2 Datacenter
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5
VMware ESXi 6.0
1
Maximum Available
Number of logical
Processors
256
1
56
640
1
56
160
56
320
480
56
56
The maximum numbers of logical processors when using Hyper-V are below
- Windows Server 2008 R2 : 64
- Windows Server 2012, Windows Server 2012 R2 : 320
NEC Corporation
Revision 1.0 – April, 2016
16
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
6 Memory
Available slots: 8 per processor
Category
Product Name / Description
Part Number
Registered DIMM
(RDIMM)
8GB DDR4-2400 REG Memory Kit (1x8GB)
1 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400)
16GB DDR4-2400 REG Memory Kit (1x16GB)
1 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400)
N8102-659F
32GB DDR4-2400 REG Memory Kit (1x32GB)
1 x 32GB Registered ECC DIMM, DDR4-2400(PC4-2400)
64GB DDR4-2400 TSV REG Memory Kit (1x64GB)
1 x 64GB TSV Registered ECC DIMM, DDR4-2400(PC4-2400)
N8102-661F
TSV Registered DIMM
(TSV RDIMM)
N8102-660F
N8102-662F
NOTE:






Minimum one memory kit per processor must be installed.
It is recommended to install memory kits in multiples of two (four identical DIMMs) for quad-channel
symmetric memory configurations to increase memory transfer speed.
When two processors are installed, balance the DIMMs across the two processors.
Mix configurations of RDIMM and TSV RDIMM are not supported
Up to 35° C ambient temperature when configured with N8102-662F 64GB DIMM
At least 5 GB of memory is required for VMware ESXi5.5 and VMware ESXi6.0.
Maximum Memory Speed
See the table below for the actual maximum memory transfer speed in Independent Channel / Memory
Sparing Configuration.
DDR4 memory speed depends on the type of DIMMs, the native memory bus speed of the memory
controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with
the lowest frequency.
The maximum memory transfer rate is 1866 MHz with Memory Sparing Configuration.
Processor Type
Populated DIMMs
DIMM Speed
E5-2609v4
RDIMM( 8, 16, 32GB)
TSV RDIMM(64GB)
RDIMM( 8, 16, 32GB)
TSV RDIMM(64GB)
1866 MHz
RDIMM( 8, 16, 32GB)
TSV RDIMM(64GB)
2400 MHz
E5-2620v4
E5-2630v4
E5-2640v4
E5-2650v4
E5-2650Lv4
E5-2660v4
NEC Corporation
Revision 1.0 – April, 2016
2133 MHz
17
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Maximum Memory Size Supported by Operating Systems
1
Microsoft Windows Server 2008 R2 Standard
1
Microsoft Windows Server 2008 R2 Enterprise
1
Microsoft Windows Server 2012 Standard
1
Microsoft Windows Server 2012 Datacenter
1
Microsoft Windows Server 2012 R2 Standard
Microsoft Windows Server 2012 R2 Datacenter
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
2
VMware ESXi 5.5
3
VMware ESXi 6.0
1
2
3
Maximum Available Memory
32 GB
2 TB
4 TB
32 GB
1TB
1TB
3 TB
1TB
4 TB
6 TB
1TB
1TB
1
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 R2 Enterprise : 1 TB
- Windows Server 2012, Windows Server 2012 R2: 4 TB
Up to 1TB of main memory is available to each virtual machine.
Up to 4TB of main memory is available to each virtual machine.
NEC Corporation
Revision 1.0 – April, 2016
18
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
7 Internal Hard Disk Drives
7.1
RAID Configuration
Refer to the section in accordance with your OS and RAID configuration. For example, when you would like
to configure RAID 0/1/10 1GB cache with Windows Server 2012 R2, refer to the section 7.2.4 for the
required components and then refer to the section 7.3.3 for the hard drives.
Operating System
Supported RAID configuration
RAID and Cache
Windows Server 2008 R2
VMware ESXi 5.5u3
VMware ESXi 6.0u1
KVM in Red Hat Enterprise Linux 6
(x86_64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6 (x86_64)
without KVM feature
Red Hat Enterprise Linux 7
Section
Supported
HDD/SSD
Non-RAID (Embedded SATA)
RAID 0/1/10
0GB Cache
7.2.1
7.3.1
7.2.3
7.3.2
RAID 0/1/10
1GB Cache
RAID 5/6
1GB Cache
RAID 5/6
2GB Cache
Non-RAID (Embedde SATA)
RAID 0/1 (Embedded SATA)
RAID 0/1/10
0GB Cache
RAID 0/1/10
1GB Cache
RAID 5/6
1GB Cache
RAID 5/6
2GB Cache
Non-RAID (Embedde SATA)
RAID 0/1/10
0GB Cache
RAID 0/1/10
1GB Cache
RAID 5/6
1GB Cache
RAID 5/6
2GB Cache
7.2.4
7.2.5
7.2.6
7.2.1
7.3.1
7.2.2
7.2.3
7.3.3
7.2.4
7.2.5
7.2.6
7.2.1
7.3.1
7.2.3
7.3.3
7.2.4
7.2.5
7.2.6
NOTE:

Up to four hard drives can be installed.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 in order to
minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
7.2
Internal Drive Configuration
7.2.1
Embedded SATA Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SATA Cable
1x Mini SAS - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch Hot-plug hard drive bays
(Standard)
Cable
Required
Drive Cage
K410-325(00)
(Standard)
NOTE:
For supported HDD/SSD, refer to 7.3.1

Hot plug insertion/removal are not supported because the drives are not redundant in this
configuration.

NEC Corporation
Revision 1.0 – April, 2016
19
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
7.2.2
Embedded SATA RAID 0/1 Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SATA Cable
1x Mini SAS - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch Hot-plug hard drive bays
(Standard)
Cable
Required
Drive Cage
K410-325(00)
(Standard)
NOTE:

For supported HDD/SSD, refer to 7.3.1

Embedded SATA RAID 0/1 controller is suported on Windows Server 2012 R2 only.
7.2.3
RAID 0/1 Controller with 0 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0GB, RAID 0/1)
Avago MegaRAID SAS 9341-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Internal SAS/SATA Cable
1x Mini SAS HD - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8103-188
Cable
Required
Drive Cage
K410-350(00)
(Standard)
NOTE:

For Supported HDD/SSD, refer to 7.3.2 for Windows Server 2008R2, Red Hat Etnerprise Linux
6(x86_64) with KVM feature, or VMware ESXi. Refer to 7.3.3 for Windows Server 2012/2012R2, Red
Hat Enterprise Linux 7 or Red Hat Enterprise Linux 6(x86_64) without KVM feature.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.
7.2.4
RAID 0/1 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1x Mini SAS HD - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8103-176
Flash Backup
Recommended
Cable
Required
Drive Cage
N8103-181
K410-350(00)
(Standard)
NOTE:

For Supported HDD/SSD, refer to 7.3.2 for Windows Server 2008R2, Red Hat Etnerprise Linux
6(x86_64) with KVM feature, or VMware ESXi. Refer to 7.3.3 for Windows Server 2012/2012R2, Red
Hat Enterprise Linux 7 or Red Hat Enterprise Linux 6(x86_64) without KVM feature.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.
NEC Corporation
Revision 1.0 – April, 2016
20
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
7.2.5
RAID 5/6 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1x Mini SAS HD - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8103-177
Flash Backup
Recommended
Cable
Required
Drive Cage
N8103-181
K410-350(00)
(Standard)
NOTE:

For Supported HDD/SSD, refer to 7.3.2 for Windows Server 2008R2, Red Hat Etnerprise Linux
6(x86_64) with KVM feature, or VMware ESXi. Refer to 7.3.3 for Windows Server 2012/2012R2, Red
Hat Enterprise Linux 7 or Red Hat Enterprise Linux 6(x86_64) without KVM feature.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.
7.2.6
RAID 5/6 Controller with 2 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1x Mini SAS HD - 1x Mini SAS HD
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8103-178
Flash Backup
Recommended
Cable
Required
Drive Cage
N8103-181
K410-350(00)
(Standard)
NOTE:

For Supported HDD/SSD, refer to 7.3.2 for Windows Server 2008R2, Red Hat Etnerprise Linux
6(x86_64) with KVM feature, or VMware ESXi. Refer to 7.3.3 for Windows Server 2012/2012R2, Red
Hat Enterprise Linux 7 or Red Hat Enterprise Linux 6(x86_64) without KVM feature.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.
NEC Corporation
Revision 1.0 – April, 2016
21
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
7.3
Supported HDD/SDD
7.3.1
For Embedded SATA Controller
Category
Drive
4 slots
available
7.3.2
SATA
HDD
(512n)
Product Name / Description
Part Number
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
N8150-489
N8150-527
For RAID Controller Configuration (1)
For Windows Server 2008R2, VMware ESXi, or KVM in Red Hat Enterprise Linux 6(x86_64)
Category
Drive
4 slots
available
SAS
HDD
(512n)
SATA
HDD
(512n)
SAS
SSD
(ME)
SATA
SSD
(ME)
NEC Corporation
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
N8150-479
Revision 1.0 – April, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
N8150-486
N8150-518
N8150-488
N8150-489
N8150-527
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
22
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
SATA
SSD
(VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.

For monitoring SATA SSD life on VMware, NEC ESMPRO Manager Ver.6.05 or later is required.
Please download the latest version on the NEC web site.

The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
7.3.3
For RAID Controller Configuration (2)
For Windows Server 2012/2012R2, Red Hat Enterprise Linux 7, or Red Hat Enterprise Linux 6(x86_64)
without KVM
Category
Drive
4 slots
available
SAS
HDD
(512n)
SAS
HDD
(4Kn)
SATA
HDD
(512n)
NEC Corporation
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
4Kn sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-479
Revision 1.0 – April, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
N8150-486
N8150-518
N8150-490
N8150-488
N8150-489
N8150-527
23
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
SAS
SSD
(ME)
SATA
SSD
(ME)
SATA
SSD
(VE)
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in the drive cage.

The 4KB sector drives are make-to-order products. Please consult your sales representative in regard
to production lead time.

When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB
sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf


4KB sector HDD and 512B sector HDD cannot be mixed.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
8 2.5-inch PCIe SSD
8.1
2.5-inch PCIeSSD Installation Kit
Product Name / Description
Part Number
2.5-inch PCIeSSD Installation Kit
Backplane board, PCIe SSD switch card, and PCIe cable
N8118-305
NOTE:

One PCIe slot is required to install the PCIe SSD switch card.

One 2.5-inch drive bay is used to install a 2.5-inch PCIeSSD.


Slot#0
Slot#2
Slot#1
PCIe
SSDSlot#3
Slot#
The PCIe SSD slot does not support hot-plug.
Operating system cannot be installed on the PCIe SSD.
NEC Corporation
Revision 1.0 – April, 2016
24
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
8.2
PCIe SSD
Category
Product Name / Description
Part Number
PCIe SSD
800GB Non-Hot Plug 2.5-inch PCIe SSD
- 1x 800 GB PCIe SSD, 2.5-inch
N8118-500
1 slot available
NOTE:

2.5-inch PCIeSSD Installation Kit is required to install this product.

Warranty period is 3 years (36 months) or until the total bytes of written value (TBW) exceeds the limit
value, whichever occurs first. It is recommended to check the TBW periodically.

Operating system cannot be installed on the PCIe SSD.
9 Optical Drive
Category
Product Name / Description
Part Number
External
External DVD Super MULTI Drive
USB, Slim DVD Super Multi drive, not including writing software
N8160-97F
10 PCI Riser Card / PCI Card
Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which
can mount PCI card supported.
10.1
PCI Riser Card
Product Name / Description
Part Number
PCIe Riser Card Kit
PCI Slot#1 : 1 x PCIe 3.0 x8
PCIe x16 Riser Card Kit
PCI Slot#2 : 1 x PCIe 3.0 x16
NOTE:
- Required for installing a PCI card in the PCI slot #2
(Standard)
10.2
N8116-36
PCI Rear Bracket
Product Name / Description
Part Number
Rear Bracket for N8104-146
Rear bracket for mounting N8104-146 on PCI Slot #1
Rear Bracket for N8104-147
Rear bracket for mounting N8104-147 on PCI Slot #1
Rear Bracket for N8104-149
Rear bracket for mounting N8104-149 on PCI Slot #1
Rear Bracket for N8104-153
Rear bracket for mounting N8104-153 or N8104-157 on PCI Slot #1
N8116-41
10.3
NEC Corporation
N8116-43
N8116-44
Network Interface Controller
Category
Adapter
N8116-42
1GbE
Product Name / Description
Part Number
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
N8104-150
Dual Port 1000BASE-T Adapter
N8104-151
Revision 1.0 – April, 2016
25
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Intel® 82580 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- PXE boot is not supported on UEFI environment.
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
10GbE
SFP+
Module
N8104-145
N8104-152
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic NetXtreme II BCM57810S
PCIe 2.0 x8, Low Profile / Full Height
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
Dual Port 10GBASE-T Adapter
Intel Ethernet Controller X540-BT2
PCIe 2.1 x8, Low Profile / Full Height
Dual Port 10GBASE-T Adapter
Intel X550
PCIe 3.0 x4, Low Profile / Full Height
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
N8104-149
N8104-153
N8104-157
N8104-129
NOTE:

When using ESXi 6.0, mix configuration of N8104-149 and N8104-150/151/152/145 is not supported.
NIC Teaming feature – NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) or Intel PROSet teaming
while Windows Server 2012 and Linux support teaming with bonding function supported by OS.
Network Interface
Team
Operating Systems
1GbE NIC
Embedded 1GbE NIC and N8104-145
Up to four ports per one team
1GbE NIC
N8104-150/-151/-152
Up to four ports per one team
10GbE NIC
N8104-149
Up to four ports per one team
10GbE NIC
N8104-153/-157
Up to four ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
(If N8104-145 is included,
Windows Server 2008 R2
only)
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Windows Server 2012
Windows Server 2012 R2
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.

The network interfaces for each NIC teaming must be the same.

When 10GbE and 1GbE NIC teams are mixed, the maximum number of teams is:
- Windows Server 2008 R2 : up to four per one system
- Windows Server 2012, Windows Server 2012 R2 : up to five per one system
NEC Corporation
Revision 1.0 – April, 2016
26
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category
Network Interface
Operating Systems
1GbE
Embedded 1GbE NIC and
N8104-150/-151/-152
N8104-145
N8104-149
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, VMware
Windows Server 2008 R2, VMware
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, VMware
Windows Server 2012, Windows Server 2012 R2, VMware
Windows Server 2012, Windows Server 2012 R2
10GbE
N8104-153
N8104-157
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.
10.4
InfiniBand
Category
Product Name / Description
Part Number
Controller
Single Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX353A-FCBT,
FDR, PCIe 3.0(x8)
Dual Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX354A-FCBT,
FDR, PCIe 3.0(x8)
InfiniBand Cable 2m/FRD
Copper
InfiniBand Cable 3m/FDR
Copper
InfiniBand Switch 36 ports/FDR
Mellanox MSX6036F-1SFR
36 ports, FDR, One power supply module included, no power
cord
Redundant Power Supply Unit
Power supply module for 36 ports InfiniBand switch, no power
cord
N8104-146
Cable
Switch
Unit
Power
Supply
N8104-147
K410-304(02)
K410-304(03)
NE3707-061
NE3707-063
NOTE:

Up to two InfiniBand adapters can be installed into the system and two adapters should be of the
same type.

The InfiniBand adapters and other options are make-to-order products. Please consult your sales
representative in regards to production lead time.
NEC Corporation
Revision 1.0 – April, 2016
27
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
10.5
External Storage Controller
10.5.1 RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit included
N8103-179
NOTE:

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.

It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
10.5.2 Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe16002B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
SAS Controller
LSI SAS9300-8e Host Bus Adapter
12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
N8190-159
SAS
NEC Corporation
Revision 1.0 – April, 2016
N8190-160
N8190-157A
N8190-158A
N8103-142
N8103-184
28
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
11 Other Add-in Components
11.1
Internal Flash Memory
Product Name / Description
Part Number
VMware ESXi support kit
Internal USB flash memory to install VMware ESXi system
N8106-010
NOTE:

The kit does not include VMware ESXi installation media and license.
11.2
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:

Up to one drive can be connected.
11.3
Boot Mode Setup Option
Product Name / Description
Part Number
Boot Mode Setup Option (Legacy Mode)
Setup option to change the OS Boot Mode to Legacy mode
NESV16-001
NOTE:

The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode.

See the table below for the Boot Mode setting for each Operating System.

As the default settings at the factory, UEFI mode is set as OS Boot mode. Order NESV16-001 Boot
Mode Setup Option (Legacy Mode) for the Operating Systems requiring Legacy Mode.
Operating System
Supported Boot Mode
Supported X2APIC Setting
Windows Server 2008 R2 (x64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6(x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5 Update3
VMware ESXi 6.0 Update1
Legacy
UEFI
UEFI
UEFI
UEFI
Legacy
Legacy
Disabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
NEC Corporation
Revision 1.0 – April, 2016
29
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
12 Add-on Components
12.1
17-inch LCD Console Drawer
Category
Drawer
Drawer
w/ KVM
Cable
Drawer
Drawer
w/o KVM
Keypad
12.2
Product Name / Description
Part Number
17-inch LCD Console Drawer (8port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD
Console Drawer (1port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch
LCD Console Drawer (1port)
N8143-106F
K410-118(1A)
K410-118(03)
N8143-105F
N8143-108F
N8143-109
N8143-111
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
N8191-14F
Cable
KVM
Cascading
NEC Corporation
Revision 1.0 – April, 2016
K410-118(1A)
K410-118(03)
K410-119(1A)
30
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
12.3
Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
N8115-04
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
Displays a graphics console on the web browser of the remote terminal
(PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
NOTE: Remote KVM and remote media features are not available for virtual machines.
NEC Corporation
Revision 1.0 – April, 2016
31
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
Boot monitoring
Alerting
Remote KVM
(via LAN)
Remote control
(via LAN)
Maintenance
Others
1
2
3
4
Temperature/voltage/power/RAID/
standard LANfan /degeneration
(memory/hard drive)
Hardware configuration information collection
Hardware event log collection
BIOS/POST stall, Booting, OS stall, shutdown
HW error, Boot error , and OS panic
(by SNMP, E-Mail)
POST/BIOS setup, ROM utility
Panic screen, Boot screen
CUI-based screen (OS console)
GUI-based screen (OS console)
Remote console recording function
Video recording
Remote reset/power on-off/ dump
Remote power capping
BIOS/BMC FW update
Remote BIOS setup(partial configuration only)
OS shutdown
Remote media (CD/DVD/FD/USB)
CLP (Command Line Protocol) (DMTF
compliant)
Remote control via Web browser (multi user
login at the same time)
Scheduling (without UPS, require NEC
ESMPRO Manager)
BIOS setting by using XML file
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)
Set automatic IP address via DNS/DHCP
LDAP/Active Directory verification/user control
Clock synchronization of main unit and the RTC
Access log collection
IPMI
IPv6(Web console/CLP only)

4
With Remote KVM
and Media License kit

4


1
 



1
 


2, 3
 
3
 




1
 











1
 




 
1
 












2.0

2.0

1
The feature is not supported on VMware ESXi systems.
Monitoring boot screens is not supported on VMware systems.
In VMware systems, only the direct console user interface is supported.
For management/monitoring/alerting features of VMware CIM Module(Avago SMI-S Provider), refer to the
following website: http://jpn.nec.com/soft/vmware/vs6/ver.html
NEC Corporation
Revision 1.0 – April, 2016
32
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times
before it fails.
The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW)
exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value
periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
Part
Number
Product Name
PBW
DWPD
Period
Monitoring Tool
N8150-721
200GB Hot Plug
2.5-inch SAS SSD
3.6PBW
10 Times
3 Years
N8150-722
400GB Hot Plug
2.5-inch SAS SSD
7.3PBW
10 Times
3 Years
Universal RAID Utility,
EXPRESSBUILDER
(System Test and
Diagnostics)
SAS SSD
SATA SSD (Middle Endurance)
N8150-725
200GB Hot Plug
2.5-inch SATA SSD
3.6PBW
10 Times
3 Years
N8150-726
400GB Hot Plug
2.5-inch SATA SSD
7.3PBW
10 Times
3 Years
N8150-727
800GB Hot Plug
2.5-inch SATA SSD
14.6PBW
10 Times
3 Years
SATA SSD (Value Endurance)
N8150-732
200GB Hot Plug
2.5-inch SATA SSD
1.1PBW
3 Times
3 Years
N8150-733
400GB Hot Plug
2.5-inch SATA SSD
3.0PBW
3 Times
3 Years
N8150-734
800GB Hot Plug
2.5-inch SATA SSD
5.3PBW
3 Times
3 Years
N8150-735
1.6TB Hot Plug
2.5-inch SATA SSD
10.7PBW
3 Times
3 Years





PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB.
DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day.
Check the lifetime of SSD by monitoring tool regularly.
It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative.
For detailed operating methods of monitoring tool, refer to the User’s Guide.
NEC Corporation
Revision 1.0 – April, 2016
33
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
OS Support Matrix for PCI Cards and Embedded Controller
ESXi 5.5
ESXi 6.0
RHEL 6 x64
RHEL 7
WS 2008R2
WS 2012
WS 2012 R2
Part number
Product Name
-
Embedded SATA non-RAID Controller
-
Embedded SATA RAID 0/1 Controller
-
Embedded 1GbE NIC
N8103-188
RAID Controller (0GB, RAID 0/1)
N8103-176
RAID Controller (1GB, RAID 0/1)
N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
N8103-178
RAID Controller (2GB, RAID 0/1/5/6)
N8103-179
RAID Controller (2GB, RAID0/1/5/6)
N8118-305
2.5-inch PCIeSSD Installation Kit
N8103-142
SAS Controller
N8103-184
N8190-159
SAS Controller
Fibre Channel Controller (1ch)
N8190-160
Fibre Channel Controller (2ch)
N8190-157A
Fibre Channel Controller (1ch)
N8190-158A
Fibre Channel Controller (2ch)
N8104-150
1000BASE-T Adapter
N8104-151
Dual Port 1000BASE-T Adapter
N8104-145
Dual Port 1000BASE-T Adapter
N8104-152
Quad Port 1000BASE-T Adapter
N8104-146
Single Port InfiniBand Adapter
N8104-147
Dual Port InfiniBand Adapter
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
N8104-153
Dual Port 10GBASE-T Adapter
N8104-157
Dual Port 10GBASE-T Adapter
NEC Corporation

- - - - - 





- - - 
- 






- - - 
- - - - 
- 
- - -
Revision 1.0 – April, 2016
34
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Supported PCI Cards and Installable Slots
Slots
Part Number
Product Name
#1
#2
-
RAID Controller (2GB, RAID 0/1/5/6)




N8103-179
RAID Controller (2GB, RAID0/1/5/6)
-
N8118-305
2.5-inch PCIeSSD Installation Kit
-
N8103-142
SAS Controller
-
N8103-184
SAS Controller
-
N8190-159
Fibre Channel Controller (1ch)
-
N8190-160
Fibre Channel Controller (2ch)
-
N8190-157A
Fibre Channel Controller (1ch)
-
N8190-158A
Fibre Channel Controller (2ch)
-
N8104-150
1000BASE-T Adapter
-
N8104-151
Dual Port 1000BASE-T Adapter
-
N8104-145
Dual Port 1000BASE-T Adapter
-
N8104-152
Quad Port 1000BASE-T Adapter
-
N8104-146
Single Port InfiniBand Adapter
N8104-147
Dual Port InfiniBand Adapter
N8104-149
10GBASE SFP+ Adapter (SFP+/2ch)
N8104-153
Dual Port 10GBASE-T Adapter
N8104-157
Dual Port 10GBASE-T Adapter
 1
 1
 1
 1
 1

















N8103-188
RAID Controller (0GB, RAID 0/1)
N8103-176
RAID Controller (1GB, RAID 0/1)
N8103-177
RAID Controller (1GB, RAID 0/1/5/6)
N8103-178
1
-
PCI Rear Bracket is required to be installed on PCI Slot #1.
NOTE:

For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only
allowing software programs with digital signature to run. The supported operating systems, software, and
boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use
other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
Operating System
Supported Boot Mode
Secure Boot Mode
Windows Server 2012
Windows Server 2012 R2
UEFI
UEFI


Software Related to Boot
Supported Boot Mode
Secure Boot Mode
System Diagnostics Utility
EXPRESSBUILDER
UEFI
UEFI


NEC Corporation
Revision 1.0 – April, 2016
35
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Supported Boot Device for Secure Boot Mode
Supported Boot Device
Part Number
RAID controller (RAID0/1)
RAID controller (1GB, RAID0/1)
RAID controller (1GB, RAID0/1/5/6)
RAID controller (2GB, RAID0/1/5/6)
N8103-188
N8103-176
N8103-177
N8103-178
Tested Linux Operating Systems
Operating Systems
Red Hat Enterprise Linux 6.7 (x86_64)
Red Hat Enterprise Linux 7.2
CentOS 6.7 (x86_64)
CentOS 7.2
NOTE:

For the latest information, go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
NEC Corporation
Revision 1.0 – April, 2016
36
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 1.0 – April, 2016
37
SYSTEM CONFIGURATION GUIDE – NEC Express5800/E120g-M
Revision History
Revision
Date
Description
1.0
April 25, 2016
Initial release
NEC Corporation
Revision 1.0 – April, 2016
38