ISL70003SEH SEE Test Report

Application Note 1913
Single Event Effects Testing of the ISL70003SEH, a 3V
to 13.2V, 6A Synchronous Buck Regulator
Introduction
amplifier for the generating the VREF voltage. High integration,
best in class radiation performance and a feature filled design
make the ISL70003SEH an ideal choice for a POL solution for
space applications.
The intense heavy ion environment encountered in space
applications can cause a variety of destructive and non
destructive effects in analog circuits, including single event
latch-up (SEL), single event gate rupture (SEGR), single event
burnout (SEB), single event transients (SET) and single event
functional interrupt (SEFI). These effects can lead to
system-level failures including disruption and/or permanent
damage. For predictable and reliable system operation, these
components have to be formally designed and fabricated for
SEE hardness, followed by detailed SEE testing to validate the
design. This report discusses the results of SEE testing of
Intersil’s ISL70003SEH, a wide input voltage range (3V to
13.2V) 6A synchronous buck regulator.
• No SETs >3% of VOUT, for 13.2V VIN to 3.3V VOUT at 3A load
Related Documents
SEE Test Objective
• ISL70003SEH Datasheet
The ISL70003SEH was tested to determine its susceptibility to
destructive effects including single event latch-up (SEL), single
event burnout (SEB) and single event gate rupture (SEGR) and
to nondestructive effects including single event transient (SET)
and single event functional interrupt (SEFI). We will discuss the
results in that order. The sample sizes reflected the
requirements of MIL-PRF-38535 (QML) and used final version
of production parts.
• ISL70003SEH Radiation Report
• AN1897 Radiation Hardened and SEE Hardened 3V to 12V,
6A Synchronous Buck Regulator Evaluation Board User’s
Guide
• AN1915 ISL70003SEH iSim:PE Mode
• AN1924 Total Dose Testing of the ISL70003SEH Radiation
Hardened Point Of Load Regulator
Product Description
The ISL70003SEH is a radiation and SEE hardened
synchronous buck regulator capable of operating over an input
voltage range of 3V to 13.2V. The part is hardened for the total
dose and single event effects environments through hardened
by design methods and uses a commercial submicron BiCMOS
power management process.
With integrated MOSFETs and external loop compensation, this
highly efficient single chip power solution provides a tightly
regulated output voltage that is externally adjustable from 0.6V
to ~85% of the input voltage. Continuous output load current
capability is 6A for TJ ≤ +125°C and 3A for TJ ≤ +150°C.
The ISL70003SEH uses voltage mode architecture with
feed-forward and switches at a fixed frequency of 500kHz or
300kHz. Loop compensation is externally adjustable to allow
for an optimum balance between stability and output dynamic
performance. The internal synchronous power MOSFETs are
optimized for high efficiency and excellent thermal
performance.
The chip features two logic-level disable inputs that can be
used to inhibit pulses on the phase (LXx) pins in order to
maximize efficiency based on the load current. The
ISL70003SEH also supports DDR power applications. It can
sink 4A of continuous load current and contains a buffer
March 2, 2015
AN1913.1
1
SEE Summary
A few of the key SEE results are summarized as follows:
• No destructive SEE at LET = 86.4MeV•cm2/mg
- Max VIN = 14.7V with 7A load
- Max VIN = 13.7V with negative inductor valley current
• No SEFIs at LET = 86.4MeV•cm2/mg with VIN > 5.5V
SEE Test Facility
Testing was performed at the Texas A&M University (TAMU)
Cyclotron Institute heavy ion facility. This facility is coupled to a
K500 superconducting cyclotron, which is capable of
generating a wide range of test particles with the various
energy, flux and fluence levels needed for advanced radiation
testing.
SEE Test Procedure
The part was tested for SEL/SEB/SEGR, using Au ions at zero
degree incidence (LET = 86.4MeV•cm2/mg) with a case
temperature of +125°C and single event transient
characterized using Au ions with a case temperature of +25°C
with the samples at zero degree incident beam angle. Single
event functional interrupt testing was done using Au ions and
Pr ions with a case temperature of +25°C. SEFI tests
conducted with Au ions were done with the samples at zero
degree incident beam angle and tests with Pr ions were done
with a 15° incident beam angle to achieve an LET of
60MeV•cm2/mg.
The device under test (DUT) was mounted in the beam line and
irradiated with heavy ions of the appropriate species. The parts
were assembled in 64 Ld quad flatpack packages with the
metal lid removed for beam exposure. The beam was directed
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2014, 2015. All Rights Reserved.
Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.
All other trademarks mentioned are the property of their respective owners.
Application Note 1913
onto the exposed die and the beam flux, beam fluence and errors
in the device outputs were measured.
Destructive SEE Results
The tests were controlled remotely from the control room. All
input power was supplied from portable power supplies
connected via cable to the DUT. The supply currents were
monitored along with the device outputs. All currents were
measured with digital ammeters, while all the output waveforms
were monitored on a digital oscilloscope for ease of identifying
the different types of SEE displayed by the part. Events were
captured by triggering on changes in the output1.
The first testing sequence looked at destructive effects due to
burnout, latch-up or gate rupture. A burnout condition is
indicated by a permanent change in the device supply current
(in any condition) after application of the beam. A permanent
change in the supply current of the device may also be indicative
of single event gate rupture, as the damaged gate insulator can
no longer control the current through integrated MOSFETs. If the
increased current can be reset by cycling power, it is termed a
non-destructive latch-up.
SEE Test Set-Up Diagrams
A schematic of the SEE engineering board used during testing is
shown in Figure 1.
BUFFER OUT
VIN
1µF
VOUT
100pF
100k
20k
7.15k
0.47µF
0.47µF
5 VREFA
9 VREFOUTS
11 VREFD
15
SYNC
16
SS
357
ISL70003SEH
10nF
LX1
LX2
LX3
LX4
LX5
LX6
LX7
LX8
LX9
LX10
24
27
33
36
39
42
45
48
54
57
1nF
17
18
19
20
21
VOUT
+ 150µF
1µF
Subsequently, four additional samples, (identified as 1A, 2A, 3A,
4A) were irradiated at 14.7V with an output current of 7A. These
samples were then irradiated with the output current set at -4.0A
(sinking) at 13.7V. Again these samples were irradiated with the
output current set at 0A (open) at 14.7V with 1 of the 4 samples
having a significant change in shut down current at this point.
1nF
8.45k
6.8nF
8.45k
6.8nF
OCB 60
SGND
AGND
DGND
PGND1
PGND2
PGND3
PGND4
PGND5
PGND6
PGND7
PGND8
PGND9
PGND10
0.22µF
3.3µH
10
52
7
8
25
26
34
35
40
41
46
47
55
56
2.7nF
2 FB
3 VERR
1 NI
64 REF
FSEL
SEL1
SEL2
DE
NC
51.1k
14
29
30
31
50
12pF
TDI
TPGM
TDO
TSTRIM
TCLK
5.49k
PGOOD
OCA 59
0.1µF
25k
3k
PGOOD 22
51 IMON
100k
0.47µF
10nF
PORVIN 4
23
28
32
37
38
43
44
49
53
58
6
10
100k
EN 12
370pF
VIMON
22k
PVIN1
PVIN2
PVIN3
PVIN4
PVIN5
PVIN6
PVIN7
PVIN8
PVIN9
PVIN10
AVDD
DVDD
5 x 1µF
100k
BUFIN+ 61
BUFIN- 62
BUFOUT 63
4x100µF
RT/CT 13
+
FIGURE 1. ISL70003SEH SEE TEST BOARD SCHEMATIC
Cross-section Calculation
Cross sections (CS) are calculated as shown by Equation 1:
CS (LET) = N/F
Destructive SEE test were done with the input voltage set to
13.7V or 14.7V, depending on whether the DUT is sourcing
current or sinking current. The samples were irradiated in three
configurations: disabled (zero output current but power applied),
output current set at +7.0A (sourcing) and output current set at
-4.0A (sinking). In all three cases the output voltage was set at
3.3V and the case temperature was maintained at +125°C using
an external heater. The failure criterion used for defining
destructive SEE was a 5% increase in operating current or a 5%
shift in the DC overcurrent protection (OCP) trip point. Failed
devices were not further irradiated.
(EQ. 1)
Tables 1 through 4, summarize the results of the destructive SEE
testing. The results demonstrate that the device passes the
objective maximum in-beam supply voltage specification of
14.7V at the specified LET of 86MeV•cm2/mg for the disabled
and sourcing current with no negative valley inductor current, and
of 13.7V in sourcing with negative valley inductor current or in
sinking configurations.
Where:
Output Voltage SET Results
• CS is the SET cross section (cm²), expressed as a function of
the heavy ion LET
Test Setup
• LET is the linear energy transfer in MeV • cm²/mg, corrected
according to the incident angle, if any.
• N is the total number of SET events
• F is fluence in particles/cm2
A value of 1/F is the assumed cross section when no event is
observed.
Submit Document Feedback
2
Single event transient (SET) testing of the ISL70003SEH was
carried out with the samples configured as a single-phase
converter operating at 3.0A output current. The samples were
irradiated using Au ions at a zero degree incident beam angle for
an effective LET of 86MeV•cm2/mg. Two different I/O
conditions were tested. The first configuration was a 3V input to
1.8V output and the second was a 13.2V input to 3.3V output.
The samples were tested at two different switching frequencies.
The first switching frequency was 300kHz generated by the
internal oscillator of the ISL70003SEH. The second frequency
was 500kHz and was generated by an arbitrary waveform
generator whose output was to connect to the SYNC pin of the
DUT. The flux for each run was 5.0 x 104 ions/cm2•s. An SET
was defined as an output voltage perturbation of ±40mV, with an
objective of not exceeding ±3% of the output voltage. The output
LC filter of the buck regulator during testing for a 3V input was a
3.3µH inductor with a single 150µF tantalum capacitor in
parallel with a 1µF ceramic capacitor for high frequency filtering
of the output voltage (see Figure 1). In the high voltage SET
testing the inductor was changed to 6.8µH.
AN1913.1
March 2, 2015
Application Note 1913
Oscilloscope Setup
Cross Section Results
An oscilloscope was used to capture the deviations of the output.
The connections for the scope are described as follows:
Table 5 details the cross section results of the SET testing of the
ISL70003SEH. The table is divided into two sections. The top
section shows the cross section results with the input to the DUT
at 3V. The bottom section shows the results for a 13.2V input to
the DUT. Each section compares the results of the cross section
due to the use of the internal oscillator versus an external
synchronization signal. A total of 8 devices were used for SET
testing. Four devices were allocated for the 3V input test and
4 devices for the 13.2V input test. Each device had two runs,
each consisting of using the internal versus external oscillator.
Oscilloscope Channel Connections and Settings:
•
•
•
•
•
CH1 = VOUT 50mV/div, trigger on ±40mV window
CH2 = LX 680mV/div for 3V, 5V/div for 13.2V
CH3 = VERR 50mV/div
CH4 = VREF 50mV/div
Time scale = 20µs/div
TABLE 1. ISL70003SEH DETAILS OF SEB/L TESTS FOR VIN = 14.7V AND DUT DISABLED
TEMP
(°C)
125
125
125
125
VIN
(V)
14.7
14.7
14.7
14.7
IOUT
(A)
N/A
N/A
N/A
N/A
LET
(MeV•cm2/mg)
86.4
86.4
86.4
86.4
SUPPLY
CURRENT
PREEXPOSURE
(mA)
97.1
98.5
96.8
99.3
SUPPLY
CURRENT
POSTEXPOSURE
(mA)
DESTRUCTIVE
EVENTS
CUMULATIVE
FLUENCE
(PARTICLES/cm2)
CUMULATIVE
CROSS
SECTION
(cm2)
DEVICE
ID
SEB
0
5.0 x 106
2.0 x 10-7
1
PASS
0
5.0 x 106
2.0 x 10-7
2
PASS
0
5.0 x 106
2.0 x 10-7
3
PASS
99.1
0
5.0 x 106
2.0 x 10-7
4
PASS
TOTAL EVENTS
0
97.3
98.2
97.1
OVERALL FLUENCE
2.0 x 107
5.0 x 10-8
OVERALL CS
TOTAL UNITS
4
TABLE 2. ISL70003SEH DETAILS OF SEB/L TESTS FOR VIN = 14.7V SOURCING 7A
SUPPLY
CURRENT
POSTEXPOSURE
(mA)
TEMP
(°C)
VIN
(V)
IOUT
(A)
LET
(MeV•cm2/mg)
SUPPLY
CURRENT
PREEXPOSURE
(mA)
125
14.7
N/A
86.4
97.1
97.1
0
5.0 x 106
2.0 x 10-7
1
PASS
125
14.7
N/A
86.4
98.6
98.5
0
5.0 x 106
2.0 x 10-7
2
PASS
125
14.7
N/A
86.4
97.1
97.7
0
5.0 x 106
2.0 x 10-7
3
PASS
125
14.7
N/A
86.4
99.1
99.1
0
5.0 x 106
2.0 x 10-7
4
PASS
125
14.7
N/A
86.4
93.6
93.5
0
5.0 x 106
2.0 x 10-7
1A
PASS
125
14.7
N/A
86.4
94.2
94.6
0
5.0 x 106
2.0 x 10-7
2A
PASS
125
14.7
N/A
86.4
91.2
92.2
0
5.0 x 106
2.0 x 10-7
3A
PASS
125
14.7
N/A
86.4
94.1
93.9
0
5.0 x 106
2.0 x 10-7
4A
PASS
TOTAL EVENTS
0
DESTRUCTIVE
EVENTS
CUMULATIVE
FLUENCE
(PARTICLES/cm2)
CUMULATIVE
CROSS
SECTION
(cm2)
DEVICE
ID
SEB
OVERALL FLUENCE
4.0 x 107
OVERALL CS
2.5 x 10-8
TOTAL UNITS
Submit Document Feedback
3
8
AN1913.1
March 2, 2015
Application Note 1913
TABLE 3. ISL70003SEH DETAILS OF SEB/L TESTS FOR VIN = 13.7V SINKING 4A
TEMP
(°C)
125
125
125
125
125
125
125
125
VIN
(V)
13.7
13.7
13.7
13.7
13.7
13.7
13.7
13.7
IOUT
(A)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
LET
(MeV•cm2/mg)
86.4
86.4
86.4
86.4
86.4
86.4
86.4
86.4
SUPPLY
CURRENT
PREEXPOSURE
(mA)
93.9
94.8
94.4
94.9
91.1
91.9
89.2
91.8
SUPPLY
CURRENT
POSTEXPOSURE
(mA)
DESTRUCTIVE
EVENTS
CUMULATIVE
FLUENCE
(PARTICLES/cm2)
CUMULATIVE
CROSS
SECTION
(cm2)
DEVICE
ID
SEB
0
5.0 x 106
2.0 x 10-7
5
PASS
0
5.0 x 106
2.0 x 10-7
6
PASS
0
5.0 x 106
2.0 x 10-7
7
PASS
0
5.0 x 106
2.0 x 10-7
8
PASS
0
1.0 x 107
1.0 x 10-7
1A
PASS
0
1.0 x 107
1.0 x 10-7
2A
PASS
0
1.0 x 107
1.0 x 10-7
3A
PASS
91.8
0
1.0 x 107
1.0 x 10-7
4A
PASS
TOTAL EVENTS
0
93.9
94.3
94.5
95.2
90.8
92.5
89.8
OVERALL FLUENCE
6.0 x 107
OVERALL CS
1.7 x 10-8
TOTAL UNITS
8
TABLE 4. ISL70003SEH DETAILS OF SEB/L TESTS FOR VIN = 14.7V, OUTPUT OPEN
TEMP
(°C)
125
125
125
125
VIN
(V)
14.7
14.7
14.7
14.7
IOUT
(A)
LET
(MeV•cm2/mg)
N/A
N/A
N/A
N/A
86.4
86.4
86.4
86.4
SUPPLY
CURRENT
PREEXPOSURE
(mA)
92.2
94.6
92.1
94.2
SUPPLY
CURRENT
POSTEXPOSURE
(mA)
DESTRUCTIVE
EVENTS
CUMULATIVE
FLUENCE
(PARTICLES/cm2)
CUMULATIVE
CROSS
SECTION
(cm2)
DEVICE
ID
SEB
0
1.5 x 107
6.7 x 10-8
1A
PASS
0
1.5 x 107
6.7 x 10-8
2A
PASS
0
1.5 x 107
6.7 x 10-8
3A
PASS
95.5
1
1.5 x 107
6.7 x 10-8
4A
FAIL
TOTAL EVENTS
1
(Shutdown Current
increased from
6.9mA to >22mA)
92.3
94.6
91.6
OVERALL FLUENCE
6.0 x 107
OVERALL CS
1.7 x 10-8
TOTAL UNITS
Submit Document Feedback
4
4
AN1913.1
March 2, 2015
Application Note 1913
TABLE 5. ISL70003SEH DETAILS OF THE SET CROSS SECTION
VIN (V)
VOUT
(V)
NUMBER OF
DEVICES
FSW (kHz)
EFFECTIVE LET
(MeV·cm2/mg)
FLUENCE PER RUN
(PARTICLES/cm2)
NUMBER OF
RUNS
TOTAL SET
EVENTS
EVENT CS
(cm2)
3.0
1.8
4
300 (internal)
86
1.0 x 107
4
1534
3.84 x 10-5
3.0
1.8
4
500 (external)
86
1.0 x 107
4
1359
3.40 x 10-5
Total Fluence per run
2.0 x 107
Total Runs
8
Total SET Events
2893
Total Cross Section
7.23 x 10-5
13.2
3.3
4
300 (internal)
86
1.0 x 107
4
1216
3.04 x 10-5
13.2
3.3
4
500 (external)
86
1.0 x 107
4
1889
4.72 x 10-5
Total Fluence per run
2.0 x 107
Total Runs
8
Total SET Events
3105
Total Cross Section
7.76 x 10-5
Voltage Deviation Results
HISTROGRAM PLOTS
Compared to other Intersil point of load (POL) regulators, the
ISL70003SEH employs a quasi-triple redundant control loop to
give system designers the ability to achieve an optimal balance
between stability and dynamic response. The quasi redundant
loop employs only one error amplifier in the control loop of the
regulator. This was needed for external compensation of the error
amplifier. There is still however redundancy in the PWM circuitry,
as the output of the error amplifier is connected to three
comparators and then its output goes through a voter circuitry to
drive the internal MOSFETs, (see Figure 2).
Figures 3 through 10 show histograms of the magnitude of the
voltage deviation for each run of SET testing for 13.2V input test.
They plot both the negative and positive transients counts and
are binned in 10mV increments up to 100mV, which represents
3% of the nominal 3.3V output voltage.
ŽŵƉϭ
&
/E
ŽŵƉϮ
sKdZ
sZ&
ŽŵƉϯ
* Blue fill indicates external compensation
FIGURE 2. ISL70003SEH QUASI REDUNDANT CONTROL LOOP
Due to the lack of three independent error amplifiers, the
ISL70003SEH is expected to have larger voltage deviations due
to SETs than its predecessors. However, it is still expected that
the LX pulse train would only have a single pulse perturbation
due to an SET since the voter logic is still employed in the PWM
circuitry.
Submit Document Feedback
5
A count that falls into the bin represents an SET whose deviation
is equal to or larger than the previous bin but less than that bin.
For example, in Figure 3 there are approximately 300 positive
SET counts that are classified in the 40mV bin. This means that
there were ~300 positive SETs that were equal to or larger than
30mV but less than 40mV.
For the 13.2V input to 3.3V output configuration the SET data
shows that majority of the SETs were positive and between 30mV
and 40mV, which translates to 0.9% to 1.2% of the output
voltage. The max deviation was a negative transient with 80mV
in magnitude found in run 217 with a count of 2. Total deviation
of 80mV translates to 2.4% of the output voltage.
Figures 11 through 18 show the histogram of the magnitude of
the voltage deviation for the 3V input to 1.8V output
configuration. The binning is done the same way as the high
voltage tests, except the max bin is now 110mV. The SET data
shows the majority of the SETs were in the negative direction and
between 50mV to 60mV, which is 2.7% to 3.3% of the output
voltage. There were three captures that fell under the 110mV bin,
one in run 201 and two in run 202. The maximum deviation was
105mV in run 201 and the ones in run 202 were 100.2mV and
100.4mV deviations. The maximum deviation of 105mV is 5.8%
of the output voltage. To minimize SETs for low input voltages, it
is recommended to add more output capacitance, which is
typical for a low output voltage that needs to meet tight
regulation. All of the SEE testing was done with a single 150µF
tantalum capacitor on the output.
AN1913.1
March 2, 2015
Application Note 1913
Histogram Plots for 13.2V Input
350
400
350
300
Positive SET
250
Negative SET
250
Frequency
# of Events
200
150
100
Positive SET
300
Negative SET
200
150
100
50
50
0
0
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
SET Deviation
SET Deviation
FIGURE 3. HISTOGRAM PLOT FOR RUN 215, fSW = 300kHz
INTERNAL OSCILLATOR
FIGURE 4. HISTOGRAM PLOT FOR RUN 216, fSW = 500kHz
EXTERNAL OSCILLATOR
300
400
350
250
Positive SET
200
Positive SET
300
Negative SET
Negative SET
150
# of Events
# of Events
250
100
200
150
100
50
50
0
0
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
SET Deviation
SET Deviation
FIGURE 5. HISTOGRAM PLOT FOR RUN 217, fSW = 300kHz
INTERNAL OSCILLATOR
FIGURE 6. HISTOGRAM PLOT FOR RUN 218, fSW = 500kHz
EXTERNAL OSCILLATOR
90
350
300
70
Positive SET
60
Negative SET
Positive SET
250
Negative SET
200
50
# of Events
# of Events
80
40
30
150
100
20
50
10
0
0
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
SET Deviation
FIGURE 7. HISTOGRAM PLOT FOR RUN 219, fSW = 300kHz
INTERNAL OSCILLATOR
Submit Document Feedback
6
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
SET Deviation
FIGURE 8. HISTOGRAM PLOT FOR RUN 220, fSW = 500kHz
EXTERNAL OSCILLATOR
AN1913.1
March 2, 2015
Application Note 1913
Histogram Plots for 13.2V Input (Continued)
10
35
9
30
8
Positive SET
25
# of Events
# of Events
10
Negative SET
6
20
15
Positive SET
7
Negative SET
5
4
3
2
5
1
0
0
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
10mV 20mV 30mV 40mV 50mV 60mV 70mV 80mV 90mV 100mV
SET Deviation
SET Deviation
FIGURE 9. HISTOGRAM PLOT FOR RUN 221, fSW = 300kHz
INTERNAL OSCILLATOR
FIGURE 10. HISTOGRAM PLOT FOR RUN 222, fSW = 500kHz
EXTERNAL OSCILLATOR
Histogram Plots for 3V Input
120
100
100
Positive SET
90
Positive SET
Negative SET
80
Negative SET
70
80
50
# of Events
# of Events
60
60
40
40
30
20
20
10
0
0
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
10mV
20mV
30mV
40mV
SET Deviation
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
FIGURE 11. HISTOGRAM PLOT FOR RUN 201, fSW = 300kHz
INTERNAL OSCILLATOR
FIGURE 12. HISTOGRAM PLOT FOR RUN 202, fSW = 500kHz
EXTERNAL OSCILLATOR
140
120
Positive SET
120
Positive SET
100
Negative SET
100
Negative SET
80
# of Events
# of Events
80
60
40
60
40
20
20
0
0
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
FIGURE 13. HISTOGRAM PLOT FOR RUN 204, fSW = 300kHz
INTERNAL OSCILLATOR
Submit Document Feedback
7
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
FIGURE 14. HISTOGRAM PLOT FOR RUN 205, fSW = 500kHz
EXTERNAL OSCILLATOR
AN1913.1
March 2, 2015
Application Note 1913
Histogram Plots for 3V Input (Continued)
120
140
Positive SET
120
Positive SET
100
Negative SET
100
Negative SET
80
# of Events
# of Events
80
60
40
60
40
20
20
0
0
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
10mV
90mV 100mV 110mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
SET Deviation
FIGURE 15. HISTOGRAM PLOT FOR RUN 207, fSW = 300kHz
INTERNAL OSCILLATOR
FIGURE 16. HISTOGRAM PLOT FOR RUN 208, fSW = 500kHz
EXTERNAL OSCILLATOR
120
100
100
Positive SET
90
Positive SET
Negative SET
80
Negative SET
70
80
# of Events
# of Events
60
60
40
50
40
30
20
20
10
0
0
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
FIGURE 17. HISTOGRAM PLOT FOR RUN 210, fSW = 300kHz
INTERNAL OSCILLATOR
Submit Document Feedback
8
10mV
20mV
30mV
40mV
50mV
60mV
70mV
80mV
90mV 100mV 110mV
SET Deviation
FIGURE 18. HISTOGRAM PLOT FOR RUN 211, fSW = 500kHz
EXTERNAL OSCILLATOR
AN1913.1
March 2, 2015
Application Note 1913
SINGLE EVENT TRANSIENT RESPONSE
The previous section provided data on the peak magnitude of the
deviation on the output voltage due to a SET. This section
provides example captures of the transient seen during SEE
testing. Figures 19 and 20 are positive and negative SET
captures for the 3V input to 1.8V output configurations.
Figures 21 and 22 show similar SET captures for 13.2V input to
3.3V output operation.
Figure 19 represents a typical negative transient, caused by a
shortened pulse in the cycle previous to time = 0, followed by
three maximum duty cycle pulses. There is clearly only a one
pulse disruption followed by the regulator adjusting its duty cycle
to recover from the disruption of normal operation. Recovery is
very controlled and duration is ~40µs. The actual time below 3%
is even shorter (<20µs). The response of the output is similar to a
transient load step in which the capacitance value dominates the
droop. As previously mentioned, adding a second capacitor on
the output would reduce the deviation by approximately half.
FIGURE 20. POSITIVE SET, RUN 204 CAPTURE 204, VIN = 3V
Figure 20 shows a positive transient when the DUT is operated
from a 3V input. Two clock cycles before trigger captures at t = 0,
one can see the increase in duty cycle of the LX pulse train due to
the ion strike, which leads to the positive SET. The larger duty
cycle increases the output voltage and the regulator corrects the
error by terminating the following LX pulses at lower duty cycles.
The recovery of the output voltage is controlled with no
oscillations and is quick with recovery to nominal output voltage
in less than 20µs.
Figure 21 is an example of a positive SET when the DUT is
operated from a 13.2V input. A single elongated pulse is seen in
the LX plot, in the clock cycle before time = 0 followed by a
shortened pulse due to the regulator trying to recover from the
increased output voltage. Recovery is controlled and less than
10µs. Once again the LX pulse train only shows one disturbance
due to an SET.
FIGURE 21. POSITIVE SET, RUN 217 CAPTURE 117, VIN = 13.2V
FIGURE 19. NEGATIVE SET, RUN 201 CAPTURE 3, VIN = 3V
Submit Document Feedback
9
AN1913.1
March 2, 2015
Application Note 1913
Figure 22, shows a negative transient when the DUT is configured to
operate from a 13.2V input. A skipped LX pulse causes a droop in
the output voltage. As a result, the error amplifier’s output increases
and induces the next pulses to have a longer on time to regulate the
output voltage to its steady state value. There is only one
disturbance in the LX pulse train that is induced by the heavy ion
strike.
Single Event Functional Interrupt Results
Single event functional interrupt (SEFI) phenomena were
encountered in previous testing of POL regulators, therefore, it
was an extensive part of SEE testing [1] [2]. SEFI phenomena for
the ISL70001SRH and ISL70002SRH were encountered only at
low supply voltage (3V), hence there was an expectation to
encounter SEFI at the same supply level. A single event
functional interrupt is defined as a non destructive event
resulting in the disruption of normal operation of the part,
followed by a recovery to normal operation through a soft-start
cycle.
For the SEFI tests, the input voltages tested were 3V, 5.5V and
13.2V. The samples were irradiated at an LET of 86 MeV•cm2/mg
and 60 MeV•cm2/mg, using Au and Pr ions respectively. The
PGOOD pin of the DUT was monitored through a scope and counts
were taken as the scope triggered on a falling edge of PGOOD. The
trigger level was set to 50% of the PGOOD pull-up voltage. Other
monitored signals included VOUT, REF and VREFA.
SEFI events were observed at 3V input and LET = 86 MeV•cm2/mg
only. No SEFI’s were seen with 5.5V or 13.2V input at
LET 86.4 MeV•cm2/mg and with 3V input at LET 60
MeV•cm2/mg. Table 6 summarizes the SEFI cross section results
of the ISL70003SEH.
FIGURE 22. NEGATIVE SET, RUN 217 CAPTURE 242, V IN = 13.2V
TABLE 6. ISL70003SEH SEFI CROSS SECTION SUMMARY
VIN
(V)
VOUT
(V)
IOUT
(A)
LET
(MeV•cm2/mg)
SPECIES
FLUENCE
(PARTICLES/cm2)
RUNS
SEFI EVENTS
CUMULATIVE CROSS
SECTION (cm2)
3.0
1.8
3
86.4
Au
1.0 x 107
8
44
5.5 x 10-7
3.0
1.8
3
60
Pr
1.0 x 107
4
0
2.5 x 10-8
5.5
1.8
3
86.4
Au
1.0 x 107
4
0
2.5 x 10-8
13.2
3.3
3
86.4
Au
1.0 x 107
8
0
1.3 x 10-8
Submit Document Feedback
10
AN1913.1
March 2, 2015
Application Note 1913
All SEFI signatures observed showed a spontaneous recovery to
normal operation. Some were restarts, while others were a
hiccup cycle (which is a dummy soft-start cycle) followed by a
restart. The recovery time is a function of the value of the
soft-start capacitor used as an SEE fixture. The SEFI cross section
for 3V input was 5.5 x 10-7/cm2, indicating a very low probability
of occurrence of this phenomenon.
Figure 23 shows an ISL70003SEH SEFI signature at
LET = 86.4 MeV•cm2/mg at 3V input. The PGOOD output drops
to zero as output voltage decays to zero. VREF remains at 600mV
and VREFA remains at 3V indicating an active regulator. The
horizontal axis is calibrated at 100µs per division.
Figure 24 shows another SEFI response with the time scale
changed to 2ms per division. This response shows the regulator
starting up ~1ms after the SEFI occurs. This is consistent with the
delay interval of 512 clock cycles seen after fault condition, such
as overcurrent protection occurs.
Figure 25 shows a SEFI signature with a hiccup cycle. In this
signature the regulator goes through a dummy soft-start before it
starts backup. In all cases, the regulator does not need a reset or
removal of power to restart.
FIGURE 23. SEFI, RUN 204 CAPTURE 2, VIN = 3V
Submit Document Feedback
11
FIGURE 24. SEFI, RUN 208 CAPTURE 1, VIN = 3V
FIGURE 25. SEFI, RUN 204 CAPTURE 1, VIN = 3V
AN1913.1
March 2, 2015
Application Note 1913
SET Results of Other Outputs
The ISL70003SEH is a highly integrated buck regulator, which
features a current monitor output and internal buffer to generate
the VREF voltage necessary in DDR power applications. In
conjunction with SET and SEFI testing of the output voltage, both
of these outputs were also monitored during SET testing. These
features were not intended to be single event transient immune
therefore, it is important to characterize their SET behavior with
cross section results and composite plots of the transient
response.
Figure 27 is a composite plot of the first 50 captures of run 220.
In this run the input voltage was 13.2V, output conditions were
3.3V output with 3A load and the regulator switching at 500kHz.
Due to the higher switching frequency, the peak current through
the regulator is smaller, this is reflected by the average VIMON
being lower in this figure compared to Figure 26. The response is
similar to previous composite plot, except for the one railed out
transient. In a worst case condition a SET on the IMON circuitry
could cause the output signal to rail to in the internal bias
(VREFA) of the ISL70003SEH.
IMON Current Sense Output SET Results
The ISL70003SEH provides a current monitor function through
the IMON pin. Current monitoring informs designers if down
steam loads are operating as expected and to measure the
overall performance of a system. The IMON pin outputs a high
speed analog current source that is proportional to the sensed
peak current through the ISL70003SEH. In typical applications, a
resistor RIMON is connected to the IMON pin to convert the
sensed current to voltage, VIMON.
For 13.2V input tests RIMON was set to 100kΩ and for 3V input
test RIMON = 50kΩ. In both configurations there was a 100pF
ceramic capacitor to reduce the switching noise in the IMON
signal. A trigger window of ±80mV was used to capture and
count the events on IMON. This equates to a ±2.7% deviation with
respect to the 3A load current.
Figure 26 is a composite plot of the first 50 captures of run 215.
In this run the input voltage was 13.2V, output conditions were
3.3V output with 3A load and the regulator switching at 300kHz.
The transients are both positive and negative with a controlled
response to its nominal value within 100µs. Peak transients in
this example is ~300mV, which equates to 10% of the load
current. Since the IMON output is not intended to be a real time
representation of the current through the regulator but a long
term diagnostic tool to evaluate the overall performance of the
system’s load, it is more important that an SET does not cause a
permanent shift in the average value than the actual peak
deviation induced by the SET.
Figures 28 and 29 show the results with a 3V input switching at
300kHz and 500kHz, respectively. RIMON = 50kΩ the VIMON
average voltage is approximately half of the high input voltage
configuration. Figure 29 the IMON signal is railed below the
capture window. In a worst case condition, the IMON signal can
swing to ground. However, the signal recovers within 100µs to its
nominal value indicating there has been no permanent change in
the load current
FIGURE 26. IMON COMPOSITE SET PLOT, RUN 215, VIN = 13.2V
FIGURE 28. IMON COMPOSITE SET PLOT, RUN 207, VIN = 3V
Submit Document Feedback
12
FIGURE 27. IMON COMPOSITE SET PLOT, RUN 220, VIN = 13.2V
AN1913.1
March 2, 2015
Application Note 1913
Buffer Output SET Results
The buffer amplifier is used to generate the reference voltage
(VREF) for the DDR memory chips. Sourcing capability of the
buffer amplifier is 10mA typical and needs a minimum of 1µF
load capacitance for stability. Typical applications will tie the
output voltage of the regulator through an R/R resistor divider
and configure the amplifier in unity gain. Figure 1 shows the
board included two 100k resistors to divide the output voltage by
half and connect to the non-inverting input of the buffer
amplifier. The amp was configured in unity gain with a 1µF
capacitor load. Two devices of each varying input voltage had an
additional 62.5Ω load to test the device at no load and loaded
condition. In DDR application, the VREF connection is a high
impedance input and the buffer amplifier, will have very light
load.
FIGURE 29. IMON COMPOSITE SET PLOT, RUN 211, VIN = 3V
Table 7 gives details of the cross section for the IMON output
signal. All tests were done with Au ions at zero degrees for an LET
of 86.4MeV•cm2/mg. Four devices were run for each
configuration, however for the 3V input test the first runs had
erroneous trigger conditions. The captures were terminated early
and the data is not used in the calculations.
Table 8 shows the cross section results of the buffer amplifier. An
SET was characterized as a ±40mV deviation of buffer output,
which coincides with the limit on VREF for DDRI applications. The
table also clearly shows the effect of loading on the counts of the
SET. As mentioned before, DDR applications will have very light
to no load on the buffer amplifier, which is a plus due to the small
cross sections achieved in the no load condition.
TABLE 7. ISL70003SEH IMON SET CROSS SECTION SUMMARY
VIN
(V)
VOUT
(V)
IOUT
(A)
FSW
(kHz)
LET
(MeV•cm2/mg)
SPECIES
CUMULATIVE FLUENCE
(PARTICLES/cm2)
EVENTS
CUMULATIVE CROSS
SECTION (cm2)
3.0
1.8
3
300
86.4
Au
3.0 x 107
3490
1.2 x 10-4
3.0
1.8
3
500
86.4
Au
3.0 x 107
3456
1.2 x 10-4
13.2
3.3
3
300
86.4
Au
4.0 x 107
5008
1.3 x 10-4
13.2
3.3
3
500
86.4
Au
4.0 x 107
6137
1.5 x 10-4
TABLE 8. ISL70003SEH BUFFER AMPLIFIER SET CROSS SECTION SUMMARY
VIN
(V)
VOUT
(V)
IOUT
(A)
BUFFER
LOAD
(Ω)
LET
(MeV•cm2/mg)
SPECIES
CUMULATIVE FLUENCE
(PARTICLES/cm2)
EVENTS
CUMULATIVE CROSS
SECTION (cm2)
3.0
1.8
3
OPEN
86.4
Au
4.0 x 107
1
2.5 x 10-8
3.0
1.8
3
62.5
86.4
Au
4.0 x 107
1979
4.95 x 10-5
13.2
3.3
3
OPEN
86.4
Au
4.0 x 107
4
1.0 x 10-7
13.2
3.3
3
62.5
86.4
Au
4.0 x 107
3866
9.67 x 10-5
Submit Document Feedback
13
AN1913.1
March 2, 2015
Application Note 1913
Figure 30 shows the composite plot for 3V input configuration
and the buffer unloaded. The graph only shows one true SET of
the buffer amplifier, the other captures are due to the SEFIs
phenomenon. The peak deviation is ~35mV and recovery is
~75µs after the peak. The response is controlled dominated by
the slew rate of the buffer amplifier and exhibits no oscillations.
A typical DDR memory will have in the order of meaning will have
somewhere around 20µF to 30µF of capacitive loading on the
buffer output, which will help further with SET mitigation.
Figure 31 shows the SET composite plot of the first 50 captures
of run 211. The input voltage is 3V and the buffer output is
loaded with 62.5Ω. The SET are mainly negative most likely due
to the load resistor to ground. Peak deviations are less than
50mV.
Figure 32 is the composite plot of run 215 with an input voltage
of 13.2V and the buffer not resistively loaded. Most likely the only
SET due to an ion hit on the buffer circuitry is the positive going
trace. The other traces are due to SETs on the output voltage
propagating through the resistor divider connected to the
non- inverting input of the buffer amp. In DDR applications the
VREF signal needs to track half of the VDDQ voltage [3]. In our
configuration the output voltage of the ISL70003SEH could be
thought of as the VDDQ voltage and the buffer amplifier is
tracking the voltage as intended.
FIGURE 31. BUFFER COMPOSITE SET PLOT, RUN 211, VIN = 3V
Figure 33 further emphasizes the theory that in Figure 32 there
is only one true SET due to the buffer amp. Figure 33 shows the
composite plot of run 217. The device is configured in similar
fashion and the responses seen on this plot is very similar to the
positive SET in Figure 32. In the calculations for cross section
mentioned previously the SET induced by tracking of the output
voltage were not used.
FIGURE 32. BUFFER COMPOSITE SET PLOT, RUN 215, VIN = 13.2V
FIGURE 30. BUFFER COMPOSITE SET PLOT, RUN 201, VIN = 3V
FIGURE 33. BUFFER COMPOSITE SET PLOT, RUN 217, VIN = 13.2V
Submit Document Feedback
14
AN1913.1
March 2, 2015
Application Note 1913
Figure 34 is the composite plot of the 50 first captures of run
222. The buffer is resistively loaded with 62.5Ω. Once again the
SETs are in the negative direction.
In all conditions the response is controlled without oscillations to
the output of the buffer amplifier. Typical DDR memory power
solutions will have 20 times the amount of capacitive loading,
which will mitigate SET. In addition, VREF is an input to a
differential pair, common-source amplifier, so there will be no
significant current draw, which SEE testing has demonstrated will
result in a very small SET cross section.
Single Event Transient
Even though complete triple redundancy is not employed in the
control loop, the ISL70003SEH provides excellent single event
transient response and we have met our goal of <3% deviation.
Further mitigation of the transient may be used by increasing the
amount of capacitance on the output filter. Testing has been
conducted with a single 150µF tantalum output capacitor.
The SEFI phenomenon is still seen on the regulator with 3V input
voltage at LET 86.4MeV•cm2/mg only and the cross section is
very small indicating a low probability of occurrence. Restart of
the IC is autonomous with no outside intervention needed to
return to normal operation. At a LET 60MeV•cm2/mg the SEFIs
go away with 3V input. SEFIs are not seen with input voltages
above 5.5V at LET 86.4MeV•cm2/mg.
Additional SET has been done on the buffer amplifier and current
monitor. Both outputs demonstrate a controlled response due to
an ion strike with no oscillations.
References
[1] JEDEC STANDARD JESD8-9A. Stub Series Terminated Logic
for 2.5V (SSTL_2)
[2] Intersil Web-based report, ‘Single Event Effects (SEE) Testing
of the ISL70002SEH Synchronous Buck Regulator’.
[3] Intersil Web-based report, ‘Single Event Effects (SEE) Testing
of the ISL70001SRH Synchronous Buck Regulator’.
FIGURE 34. BUFFER COMPOSITE SET PLOT, RUN 222, VIN = 13.2V
Summary
Destructive SEE
No SEL/SEB/SEGR was observed for the device up to an LET of
86.4MeV•cm2/mg (+125°C) at a maximum voltage supply of
VIN = 14.7V when the DUT is disabled or sourcing to the
maximum rated load current, providing over 10% margin to the
maximum recommended input voltage of 13.2V.
Applications that result in a negative inductor valley current are
limited to maximum voltage supply of VIN = 13.7V, a 3% margin
to the maximum recommended input voltage of 13.2V. In DDR
applications typical input voltages are from 3.3V or 5V rails and
13.7V provides more than enough headroom to use this device
as a V TT termination regulator.