TITANIUM COMPATIBLE LASER WELDABLE 50 OHM FEEDTHROUGH
SMP ADAPTABLE, .015 DIAMETER CENTER CONTACT, PRESS-IN
D
2
3
DOCUMENT
SRIFT1020
REVISIONS
REV
DCN
REV DATE
RELEASE APPROVAL
-
INIT RLSE
2011-09-12
J. PETRI
A
DCN001208
2013-10-15
• CONFIGURATION FOR INTERFACING TO SMP "BULLET" STYLE ADAPTER
• DESIGNED TO LASER WELD INTO AN ELECTRONIC CHASSIS WALL
D
• INDUSTRY STANDARD NICKEL-IRON-COBALT ALLOY CONTACT WITH CORNING 7070
EQUIVALENT GLASS
• INTEGRAL RF GROUNDING TAB FOR EXCELLENT PERFORMANCE OVER TEMPERATURE
• DROP-IN HIGHER PERFORMANCE REPLACEMENT FOR SRIFT1001 STYLE CONNECTORS.
1. LEAK RATE: LESS THAN OR EQUAL TO 1X10E-9 CC/SEC He AT ONE ATMOSPHERE DIFFERENTIAL PRESSURE.
2. NOMINAL IMPEDANCE: 50 OHMS
3. INTERFACE IN ACCORDANCE WITH MIL-STD-348, SMP.
4. MATERIALS:
PIN: NICKEL-IRON-COBALT ALLOY IN ACCORDANCE WITH ASTM F15
DIELECTRIC: CORNING 7070 EQUIVALENT GLASS (MATCHED SEAL)
SHELL (WELD FLANGE): TITANIUM GRADE 2 (UNALLOYED) IN ACCORDANCE WITH ASTM B265 OR B348
RF GROUNDING SPRING: BERYLLIUM-COPPER ALLOY 172/173 IN ACCORDANCE WITH ASTM B 194 (NICKEL AND GOLD PLATED)
C
5. FINISH, CONTACT AND SHELL (EXCEPT WELD FLANGE):
NICKEL PLATE PER QQ-N-290, CLASS 2, .000100/.000250 THICK.
GOLD PLATE PER ASTM B488, TYPE III, CODE A, .000050/.000150 THICK.
C
A
6. ORDERING INSTRUCTIONS:
SPECIFY BASE NUMBER FOLLOWED BY DASH NUMBERS INDICATING DETENT TYPE, PIN LENGTH, AND DIELECTRIC APPLICATION.
EXAMPLE: SRIFT1020 - FD 130 A R
ADD R FOR FULL RADIUS PIN END CONFIGURATION
A=GROUNDING SPRING FOR AIR DIELECTRIC
T=GROUNDING SPRING FOR TEFLON DIELECTRIC
PIN LENGTH, L=.130
DETENT (FD=FULL, LD=LIMITED, SB=SMOOTH)
BASE NUMBER
B
B
UNLESS OTHERWISE SPECIFIED
A
DIMENSIONING IAW ASME Y14.5M-1994
DIMENSIONS APPLY AFTER PROCESSES
DIMENSIONS IAW US CUSTOMARY UNITS
.X .1, .XX .01, .XXX .005,
.5
.010 MAX OUTSIDE R, .005 MAX INSIDE R
125 RMS SURFACE FINISH
THIRD ANGLE PROJECTION
SRI HERMETICS
TITLE
FEEDTHROUGH, SMP, TC LBW, PRESS-IN
SIZE DOCUMENT
A
SCALE
FORM 300067 REV -
7
6
5
4
3
(321) 254-4067
WWW.SRIHERMETICS.COM
8:1
2
CAGE CODE
SRIFT1020
3PJY7
SHEET
1
REV
A
1 OF 2
A
6
7
8
4
5
2
3
DOCUMENT
SRIFT1020
.200
L±.003
.108
D
D
.015±.001
.192 MAX
OVER KNURL
PIN END CONFIGURATION
WELD FLANGE
CONTACT
FERRULE
SHELL
STRAIGHT KNURL
VIEW SHOWN WITHOUT GROUNDING SPRING
C
C
.049 .001
.035 .001 THRU (AIR DIELECTRIC)
SHOWN (TEFLON DIELECTRIC, OPTIONAL)
.118 .0005
SHOWN
.188 .001
SHOWN
.248 MIN
.005 .002
.195±.001
A
A
.161±.002
INSTALL THIS DIRECTION
AS REQUIRED
.035 (AIR DIELECTRIC APPLICATION)
.050 (TEFLON DIELECTRIC APPLICATION)
A
.115±.002
8X 45°
NO PLATING
B
A
B
.010 MAX BRK
ALL AROUND
8X .012
.003 MAX BRK
RF GROUNDING SPRING, SHIPPED UNINSTALLED
PART NUMBER SRIFT1020-GS1, AIR DIELECTRIC
PART NUMBER SRIFT1020-GS2, TEFLON DIELECTRIC
O
UNLESS OTHERWISE SPECIFIED
A
DIMENSIONING IAW ASME Y14.5M-1994
DIMENSIONS APPLY AFTER PROCESSES
DIMENSIONS IAW US CUSTOMARY UNITS
.X .1, .XX .01, .XXX .005,
.5
.010 MAX OUTSIDE R, .005 MAX INSIDE R
125 RMS SURFACE FINISH
SUGGESTED HOLE DETAIL
THIRD ANGLE PROJECTION
SRI HERMETICS
7
6
5
4
3
(321) 254-4067
WWW.SRIHERMETICS.COM
TITLE
FEEDTHROUGH, SMP, TC LBW, PRESS-IN
SIZE DOCUMENT
A
SCALE
FORM 300067 REV -
.0020±.0005
10:1
2
CAGE CODE
SRIFT1020
3PJY7
SHEET
1
REV
A
2 OF 2
A