Factory Modification Kits

Factory Modifications
Selection
Ordering Information
�
All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction
may not apply when certain modifications and special features are added.
NEMA & General
Purpose Control
Pilot Devices
Description
Modification
Push Buttons
Selector Switches
Start, Stop
Forward, Reverse, Stop
High, Low , Stop
E-Stop
Test Push Buttons
Hand-Off-Auto
For 24 volt HOA control, 20 Amp contactor only
Off-On
Auto-Off
Forward-Off-Reverse
High-Off-Low
Hand-Off-Auto (Keyed)
Auto-Off-Low-High
17
Enclosure
Type
Suffix
14, 17, 18, 36, 37, 40, 83, 84, CLM, CM, LE
22, 25, 26, 43
30, 32
14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43
83, 84
14, 17, 18, 36, 37, 40, 83, 84, LE
CM, CLM
All
All
All
All
All
All
All
A1
A2
ES
K1
A3
A3
CM, CLM
1
EM
14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43,
83, 84, CLM, CM, LE
14, 17, 18, 40, 83, 84, CM, CLM, LE
22, 25, 26, 43
30, 32
14, 17, 18, 36, 37, 40, 83, 84, LE, CLM, CM
30, 32
All
All
All
All
All
All
A4
A6
List Price $
e
e
e
e
A5
A9
A0
e
Pilot Lights
Enclosure
Type
Class
CONTROL
PRODUCTS
Class
Lens
Color ➔ Red
Green
Red
On
On
For/Rev
For/Rev Legend➔ Low/High Low/High Run
Suffix ➔ FA
FB
14, 40, 17, 18, 36, 37, 87, 88, LE, CLM, CM All
22, 25, 26, 30, 32, 43, 83, 84
All
FC
h
Green Red Green Amber
White
Red
Green
Green
LED Bulb
Push-To-Test Push-To-Test Push-To-Test Upgrade
Run
Off
Off
Control On
OL
Power For/Rev
Tripped On
Low/High
On
For/Rev
Low/High
Off
FD
FJ
FK
FLd FT
FU
h
FW FS
FEa
Coil Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83f , 84f , 87, 88
Controller Size — List Price $
Volts 60 HZ
Volts 50 HZ
Coil Letter
Change
00–21⁄2
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
J
F
A
D
G
L
C
H
E
DC Coil c
24V
48V
125V
250V
S g
U
V
W
3, 31⁄2
4
AC (50–60 HZ) or DC
Coil Letter
Change
J
U
F
D
G
L
K
H
E
23–26V
42–48V
110–127V
200–220V
220–240V
240–277V
380–420V
440–480V
575–600V
Pilot lights are transformer type as standard. For LED
type bulbs, order suffix FE in addition to the standard
device suffix(es). For example, to order red “ON” and
green “OFF” pilot lights with LED bulbs, order FA,
FK and FE.
17-108
Miscellenious Options
.
Class
Omit Alternator
(deduct)
a
Controller Size 4 (Vacuum Only)
Size 5 & 6 (ALL)
C coils include 1 NC, late break aux. contact. This
D
aux. contact takes up one side of the starter (00–4
only).
c Price x 2 for Classes 22, 25, 26, 30, 32, 43, 83, 84.
d Bimetal OL - Size 00 - 2 1/2 available. Solid-state OL Size 00 - 4, 7 & 8 available.
b
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
83, 84
Change the 92 to
List
Price $
95
For Class 83, 84 two devices are provided. Price x 2.
For Class 83, 84 standard enclosure (92) alternating
relay available in 24V or 120V control only.
g S coil is not available for size 4 contactors or starters.
h Class 83 and 84 only.
e
f
Product Category: NEMA
• Revised •
02/21/12
Factory Modifications
Selection
Ordering Information
Transformer Table
Replace (*) with letter from Transformer Table.
�
Primary
Volts
120
208
208
240
240
277
277
380
415
480
480/240
480/240
600
600
Secondary
Volts
24
24
120
24
120
24
120
110
100
240
24
120
24
120
Letter
B
S
T
J
F
N
P
U
W
R
D
A
E
C
Control Power Transformers
Catalog Product
No Suffix Class
Standard Capacity a with 1-Secondary Fuse
Standard Capacity
with 2-Primary and
1-Secondary Fuse
100VA Extra Capacity
with 2-Primary and 1-Secondary Fuse
150VA Extra Capacity
with 2-Primary and
1-Secondary Fuse
B*
D*
C*
C*1
Enclosure 20–60
Type
0–2 1⁄2
14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87
14, 17, 18, 22, 25, 26, 30,
32, 40, 43, 83 , 84 , 87,
LE, CLM, CM
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 83 , 84 , 87, LE, CLM, CM
36, 37, 88
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 83 , 84 , 87, LE, CLM, CM
36, 37, 88
1, 3, 4, 12
7 & 9
100
—
200
300–400
—
—
3
31⁄2, 4
5
6
7
8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Lighting & Heating Ratings (Amps)
Motor Controller Size
1, 3, 4, 12
7 & 9
1, 3, 4, 12
7 & 9
All
NEMA & General
Purpose Control
Description
1, 3, 4, 12
All
Factory Assembled Fuse Clips—Class 25, 32, 84d
Fuse
Clip Amps
Note: Factory will furnish the same voltage coils as
transformer secondary voltage (except with class
36,37).
Product Category: NEMA
List Price $
10
11
12
13
14
15
16
17
18
19
20
21
23
24
25
CONTROL
PRODUCTS
250
600
250
600
250
600
250
600
250
600
250
600
600
600
600
Suffix
17
30
30
60
60
100
100
200
200
400
400
600
600
800
1200
1600
Volts
a The
standard control transformer supplied for starter
sizes 0 through 21⁄2 will be rated 45VA and have the
appropriate secondary fuse. Primary fuses will not be
supplied as standard. For primary fuse option select appropriate suffix from table.
 For 24VAC control a minimum of 100VA CPT required.
 Price x 2 Class 83 and 84.
d Class 84 Duplex Controllers require two fusible
disconnects thus multiply the price adder by two.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-109
Factory Modifications
Selection
Additional Auxiliary Contacts
Class
14, 17, 18, 40, 83
, 84c
c
22, 25, 26, 43 & 30, 32 (2-winding)
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
30, 32
(1-winding)
LE, CLM, CM
CLM, CM
NO
Contacts
NC
Contacts
Controller Size — List Price $
Catalog Number 2–4
5–6
Suffix
00–13⁄4
—
—
1
1
1
2
2
2
2
3
3
3
4
4
4
4
5
5
5
6
6
7
8
—
2
2
4
4
6
8
1
2
—
1
2
—
1
2
3
1
2
3
—
1
2
4
—
1
3
—
2
1
—
2
—
2
0
4
2
0
G01
G02
G10
G11
G12
G20
G21
G22
G23
G31
G32
G33
G40
G41
G42
G44
G50
G51
G53
G60
G62
G71
G80
G02a G20a G22a G40a G44a G62a G80a 0
2
2
4
4
6
8
1
0
2
2
2
—
2
—
4
2
—
1
2
0
2
G02a G20a G22a G40a G44a G62a G80a G11
G02a
G20a
G22a
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
7–8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Overload Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37
Description
Ambient Compensated
Bimetal
ESP200
3RB200 (Sz 5-6)
Trip
Class
Phase
Contacts
Catalog Number Controller Size—List Price $
3–4
Suffix
00 –21⁄2
Class 10 or 20
(K or E heaters)
Class 5, 10, 20,
30 selectable
Class 10
Class 20
3-Phase or
Single Phase
3-Phase or
Single Phase
3-Phase
3-Phase
NO & NC, SPDT
91
b
—
—
—
NC
81
—
—
—
—
NO & NC
NO & NC
NO & NC
N/A —
—
—
—
—
—
—
—
—
—
51
—
—
—
5, 6
7, 8
Controller Size - Price Deduction $
Description
Class
Suffix
Omit Overload Relay and Reset Button
17, 18, 25, 26
EX1
a Auxiliary
contacts will be added evenly across
contactors. (i.e. Class 22, G02 suffix will add 2 NC
contacts (one per contactor).
17-110
0, 1
13⁄4 - 21⁄2
3
31⁄2, 4
5, 6
7, 8
b Double the price addition for Class 30 and 32.
c For class 83 and 84 contacts will be added to both
starters. Price x 2.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Product Category: NEMA
• Revised •
02/21/12
Factory Modifications
Selection
Control Options
Description
Lighting Control Modules
Surge Suppression for 120V AC Coilb
Disconnect Switch Interlock 2 NO/2 NC
DPDT
Motor Circuit
NO/NC
SPDT
Protector Interlock
Lightning Arrestor
Circuit Breaker Shunt Trip
Circuit Breaker Undervoltage Trip
Circuit Breaker Alarm Switch Trip
Ground Lug – 1 Conductor
Control Circuit Fuse and Holder
(Transformer Primary Fusing) Control Circuit Circuit Breaker Internally Operated
Space Heater (120V separate control)
Space Heater with Thermostat (120V separate control) Surge Capacitor
Alarm Package (includes horn, light, relay & push-button)
Backspin Protection
Minimum Run Timer 0.2 sec. - 3 mins.
Blown Control Fuse Indicator Light
Single Phase 120VAC Combination Starter
Single Phase 240VAC Combination Starter
Class
Enclosure
Type
Catalog Number
Suffix
CLM 20 Amp
14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88
17, 25, 32, 37, 84, CM, LE
All
All
1, 3, 4, 4X, 12
2W, 3W, 3WS
SS
GY
18, 26, 32, 37, 84, CM, LE
All
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
All
All
GY
All
All
All
All
All
All
All
L
L6
L7
L8
L10
F1 (1 fuse)
F2 (2 fuses)
All
All
All
87, 88
83, 84, 87, 88
87, 88
87, 88
17, 25, 32, 37, 84, 87, 88, CM, LE
17, 18, 25, 26
17, 18, 25, 26
All
All
All
All
All
All
All
All
All
All
F4
List
Price $
SH
ST
SC
M7
T5
T6
L11
SP1
SP2
Reversing Options
Reversing in one speed only 2 speed 1 winding
Reversing in one speed only 2 speed 2 winding
Reversing in both speeds 2 speed 1 winding
Reversing in both speeds 2 speed 2 winding
Reversing for Reduced Voltage
Class
Catalog Number
Suffix
R6
R7
R8
R9
R
30, 32
36, 37
Controller Size —List Price $
0
13⁄4
1
2
21⁄2
3
31⁄2
4
5
—
—
—
—
NEMA & General
Purpose Control
Description
Enclosure Options Class 14, 17, 18
Change the 7th Character
of the Catalog Number
with Bimetal Overload
Relay to:
X
X
X
Change the 8th Character
of the Catalog Number
with Solid State
Overload Relay to:
X
X
X
Controller Size – List Price Adder $
2–2 1/2
3
00–1 3/4
3 1/2–4
5–8
—
—
—
Note: Add price to the standard 304 stainless steel unit price.
Motor Management with PROFIBUS DP Communications
Description
Class
SIMOCODE pro C With 0.3-3A Current Module
SIMOCODE pro C With 2.4-25A Current Module
SIMOCODE pro C With 10-100A Current Module
SIMOCODE pro C With 20-200A Current Module
SIMOCODE pro C With 63-630A Current Module
SIMOCODE pro V With 0.3-3A Current/Voltage Module
SIMOCODE pro V With 2.4-25A Current/Voltage Module
SIMOCODE pro V With 10-100A Current/Voltage Module
SIMOCODE pro V With 20-200A Current/Voltage Module
SIMOCODE pro V With 63-630A Current/Voltage Module
Factory Parameterization of SIMOCODE
a Supplied as NEMA 12, field convertible to NEMA 3R.
b Surge Suppression for NEMA sizes 5 – 8 are supplied
internal with the coil.
Product Category: NEMA
14,17,18,22,25,26
Enclosure Type
Suffix
All
MC1
MC2
MC3
MC4
MC5
MV1
MV2
MV3
MV4
MV5
MM0
List Price
 A
CPT must also be ordered to power the motor management device. Motor management may be ordered
with other product classes as specials.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-111
CONTROL
PRODUCTS
Enclosure
Type
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)
17
Class
14
14 (Extra Wide)
17 & 18
Factory Modifications
Selection
Control Relays
Description
4 NO
Control Relay a 2 NO /2 NC 4-Poles Max
4 NC
Under/Over Voltage, Phase Failure, Phase Sequence, Phase Unbalance
Ground Fault Relay
Electronic On Delay Relay (.15s–100h) 24V/120V a ab Electronic On Delay Relay (.15s–100h) 24V/240V
Electronic Off Delay Relay (.15s–100s) 120Va Electronic Off Delay Relay (.15s–100s) 240Vab 24 hour time clock
24 hour time clock with day omission 7 day time clock
Compelling Relay
Acceleration Control
Deceleration Control
Class
Enclosure
Type
Suffix
All
All
LE, CLM, CM
30, 32
1, 3, 4, 7, 9, 12
All
All
1, 3, 4, 7, 9, 12
R40
R22
R04
R1f
R5
T1
T2
T3
T4
T7
T8
T9
A6
A7
A8
All
1, 4, 12
List
Price $
Description
Ammeter (includes a C.T. if necessary) Ammeter and Switch (3-Phase with 3 C.T.’s)
Voltmeter
Voltmeter and Switch (3-Phase)
Elapsed Time Meterd Wattmeter
Class
Enclosure
Type
Suffix
14, 17, 18, 22,
25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88
1, 3, 4, 4X, 12
M1
M2
M3
M4
M5
M6
c
List
Price $
Function Identification Plates
Description
Class
Suffix
Function identification plate, with marking as specified
All
N1
List Price $
Terminal Blocksa
Description
Class
Suffix
3 Point Terminal
6 Point Terminal
9 Point Terminal
TC3e
TC6e
TC9e
17
All
Special Ratings
Description
Class
Suffix
CONTROL
PRODUCTS
NEMA & General
Purpose Control
Meters—Mounted on Enclosure
Service Entrance Rating
17, 18, 25, 26, 32, 37, 84, 87
N3
List Price $
List Price $
Drawings
Description
Class
Catalog Number
Approval/submittal and as-built drawings for factory modified
product may be ordered. The drawing set includes an enclosure outline, a panel layout and a schematic. When entering
the order, use the line item notes to reference a product and
modifications or an existing order that the drawings are to
be engineered for. Specify the contact information and an
email address in the ship to address field. Attach any reference drawings to the order or forward to National Customer
Support. Once completed, the drawing set will emailed.
All
CONTROLDRAWING
a Supplied mounted and unwired.
b Not available on Class 36, 37.
c Price x 2 Class 83 and 84.
17-112
d ETM available with 120V coil
e For terminal point more than
List Price $
only.
9 terminals use
additional suffixes. Max 3 suffixes can be selected.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
f Available
3-Phase only.
30 and 32 can be modified with only an elapsed
time meter. No other meters apply to class 30 or 32.
Class
Product Category: NEMA