MultiRanger 200 HMI ultrasonic level controller Catalog Sheet

© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 200 HMI
■ Overview
■ Application
MultiRanger 200 HMI can be used with various materials, including, water, municipal waste, acids, woodchips, or on materials
with high angles of repose. MultiRanger 200 HMI offers true dual
point monitoring, digital communications with built-in Modbus
RTU via RS 485, as well as compatibility with SIMATIC PDM, allowing PC configuration and set-up. MultiRanger 200 HMI features Sonic Intelligence advanced echo-processing software for
increased
reading reliability.
MultiRanger 200 HMI will monitor open channel flow and features more advanced relay alarming and pump control functions
as well as volume conversion.
It is compatible with chemical-resistant EchoMax transducers
that are approved for hostile environments.
• Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins,
dry solids storage
4
MultiRanger 200 HMI is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually
any application in a wide range of industries.
■ Benefits
• Easy to use HMI display with local four-button programming,
menu-driven parameters, and Wizard support for key applications
• English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI
• Removable terminal blocks for ease of wiring
• Digital input for back-up level override from point level device
• Communication using built-in Modbus RTU via RS 485
• Compatible with SmartLinx system and SIMATIC PDM
configuration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise
reduction and improved signal-to-noise ratio
• Level, volume, and flow measurements in open channels,
differential control, extended pump control, and alarm
functions
• Wall and panel mounting options
4/1
Siemens FI 01 · News 10/2015
■ Design
The MultiRanger 200 HMI is available in wall or panel mounting
options.
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 200 HMI
■ Technical specifications
Mode of Operation
Design
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft)
Measuring points
1 or 2
Input
Weight
• Wall mount
• Panel mount
1.37 kg (3.02 lb)
1.50 kg (3.31 lb)
Material (enclosure)
Polycarbonate
IP65/Type 4X/NEMA 4X
IP54/Type 3/NEMA 3
Analog
0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable
Degree of protection (enclosure)
• Wall mount
• Panel mount
Discrete
10 ... 50 V DC switching level
Logical 0  0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Electrical connection
• Transducer and mA output signal
Output
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
• Max. separation between transducer 365 m (1 200 ft)
and transceiver
EchoMax transducer
44 kHz
Ultrasonic transducer
Compatible transducers: ST-H and
EchoMax series XPS-10, XPS-15/15F,
and XRS-5
Relays
Rating 5 A at 250 V AC, non-inductive
Power supply
mA output
• Max. load
• Resolution
0 ... 20 mA or 4 ... 20 mA
750 , isolated
0.1 % of range
AC version
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA (17 W)
DC version
12 ... 30 V DC (20 W)
Certificates and approvals
• CE, RCM2)
• FM, CSAUS/C, UL
• CSA Class I, Div. 2, Groups A, B, C
and D, Class II, Div. 2, Groups F and
G, Class III (wall mount only)
Communication
• RS 232 with Modbus RTU or
ASCII via RJ-11 connector
• RS 485 with Modbus RTU or
ASCII via terminal strips
• Optional: SmartLinx cards for
- PROFIBUS DPV1
- DeviceNet
Accuracy
Error in measurement
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Resolution
0.1 % of measuring range1)
or 2 mm (0.08 inch), whichever is
greater
Temperature compensation
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
values
Rated operating conditions
Installation conditions
• Location
• Installation category
• Pollution degree
Indoor/outdoor
II
4
Ambient conditions
• Ambient temperature (housing)
-20 ... +50 °C (-4 ... +122 °F)
Displays and controls
60 x 40 mm (2.36 x 1.57 inch) LCD
240 x 160 pixels resolution
1)
Program range is defined as the empty distance to the face of the transducer plus any range extension
2)
EMC performance available on request
Siemens FI 01 · News 10/2015
4/2
4
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 200 HMI
Selection and Ordering data
Article No.
Selection and Ordering data
MultiRanger 200 HMI
Versatile short to medium-range ultrasonic single
and multi-vessel level monitor/controller for virtually
any application in a wide range of industries
7ML5033-
Further designs
7 7 7 77 - 77
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: ¢ Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Versions
MultiRanger 200 HMI, level, volume, flow, and diffe-¢ 2
rential measurements
Mounting
4 button HMI, Wall mount, standard enclosure
4 button HMI, Wall mount, 4 entries, 4 M20 cable
glands included
4 button HMI, Panel Mount
4
Input voltage
100 ... 230 V AC
12 ... 30 V DC
¢
¢
Number of measurement points
Single point version
Dual point version
¢
¢
Article No.
English
AE535857004
German
A5E36182123
F
Note: The instruction manual should be ordered as a
separate line on the order.
This device is shipped with the Siemens Milltronics
manual DVD containing the complete ATEX Quick
Start and instruction manual library.
A
B
Other Operating Instructions
0
1
0
2
SmartLinx DeviceNet module
¢
3
4
See SmartLinx product page for more information.
¢
Approvals
General Purpose CE, FM, CSAUS/C,
¢
UL listed, RCM
CSA Class I, Div. 2, Groups A, B, C, and D; Class II, ¢
Div. 2, Groups F and G; Class III1)
1)
C11
Operating Instructions
¢
¢
SmartLinx PROFIBUS DPV1 module
Test Certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
D
E
Data communications (SmartLinx)
Without module
SmartLinx PROFIBUS DPV0 module
Output relays
6 relays (4 Form A, 2 Form C), 250 V AC
Order code
SmartLinx PROFIBUS DPV1, English
A5E36197302
SmartLinx PROFIBUS DPV1, German
A5E36197305
SmartLinx PROFIBUS DP, English
7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
7ML1998-1AQ33
SmartLinx PROFIBUS DP, French
7ML1998-1AQ13
SmartLinx DeviceNet, English
7ML1998-1BH02
Note: The appropriate SmartLinx Operating
Instructions should be ordered as a separate line
on the order.
2
1
2
Available with Mounting/Enclosure design options D or E
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
Optional equipment
Handheld programmer
7ML1830-2AK
Tag, stainless steel, 12 x 45 mm, one text line,
suitable for enclosures
7ML1930-1AC
Sun-shield, 304 Stainless steel
7ML1930-1GA
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
Spare parts
Power Supply Board (100 ... 230 V AC)
7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
7ML1830-1ME
Replacement lid with 4 button HMI
A5E35778738
SmartLinx PROFIBUS DP V1 module
A5E35778741
¢ We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol ¢. For details see page 9/5 in the appendix.
4/3
Siemens FI 01 · News 10/2015
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 200 HMI
■ Dimensional drawings
Panel mount dimensions
198 (7.8)
94
(3.7)
278 (10.9)
31
(1.2)
4
Wall mount dimensions
15
(0.6)
161 (6.3)
87 (3.4)
15
(0.6)
131 (5.2)
6
(0.2)
228 (9.0)
240 (9.4)
Lid screws
(6)
Cable entry
location
Enclosure
lid
Cable Enclosure
entry
base
Ø4.3 (0.17),
four mounting holes
MultiRanger 200 HMI, dimensions in mm (inch)
Siemens FI 01 · News 10/2015
4/4
© Siemens AG 2015
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 200 HMI
■ Schematics
TB1
Or
See note 1
TB1
TB2
L2/N L1
+
-
- +
2
TB3
12 ... 30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
4 ... 20 mA
OUTPUTS
Relay 2
+
2
4
+
+
Relay 3
TS-3
SHIELD
1
Relay 4
Relay 5
DISCRETE
INPUTS
2
COM
Relay 6
Relays shown in released
state
RS 485
A
B
Note:
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
3. Connect all cable shields to the MultiRanger shield connections.
Avoid differential ground potentials by not connecting cable shields
to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
MultiRanger 200 HMI connections
4/5
Siemens FI 01 · News 10/2015