© Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Technical description ■ Application The remote seals 7MF48.. can be fitted to SITRANS P transmitters for • pressure (7MF4033 and 7MF4034), • absolute pressure (7MF4233, 7MF4234, 7MF4333, 7MF4334) and • differential pressure and flow (7MF4433, 7F4434 and 7MF5403 and 7MF5413). ■ Design and mode of operation A remote seal system consists of a transmitter, one or two remote seals, an appropriate transmission liquid, and a connection between the transmitter and remote seal (direct mounting or capillary). Diaphragm seal of pancake design, and also with extended diaphragm (extension) The volume in contact with the measured medium is defined by an flexible diaphragm. The volume between this diaphragm and the pressure transmitter is completely filled with a transmission fluid. If a pressure is now applied to the remote seal, this is transmitted via the flexible diaphragm and the fill fluid to the pressure transmitter. In many cases, a capillary is located between the remote seal and the pressure transmitter in order e.g. to minimize temperature effects from the hot medium on the latter. However, the capillary line influences the response time and the temperature response of the complete remote seal system. When fitting remote seals to differential pressure transmitters, two capillaries of the same length must always be used. Diaphragm seal of flush flange design, and also with extended diaphragm (extension) ■ Fields of use Remote seal systems should be used if a separation between the measured medium and the measuring instrument is appropriate or essential for the following reasons: • The temperature of the medium is outside the limits specified for the transmitter. • The medium is corrosive and requires diaphragm materials in the transmitter which are not available. • The medium is highly viscous or contains solids which would block the measuring chambers of the transmitter. • The medium may freeze in the measuring chambers or impulse line. • The medium is heterogeneous and fibrous. • The medium tends towards polymerization or crystallization. • The process requires quick-release remote seals, as necessary e.g. in the food industry for fast cleaning. • The process requires cleaning of the measuring site, e.g. in a batch process. ■ Constructional designs A differentiation is made between diaphragm seals and inline seals. With the diaphragm seals, the pressure is measured via a flat convoluted diaphragm welded to a convoluted backup. With the inline seals, the pressure is measured via a cylindrical diaphragm positioned in a pipe, and transmitted to the transmitter via the filling liquid. The inline seal is a special design for flowing media. It consists of a cylindrical pipe in which a cylindrical diaphragm is embedded. Since it is completely integrated in the process pipe, no turbulences, dead volumes or other obstructions to the flow occur. 1/206 Siemens FI 01 · 2015 US Edition Tri-Clamp sanitary remote seal Diaphragm seals The following types of diaphragm seals exist: • Pancake design, and pancake design with extended diaphragm (extension) to DIN or ANSI which are secured using a backup blind flange. • Flush flange design, and flange design with extended diaphragm (extension) to DIN or ANSI which are installed by using holes in the flange. • Sanitary remote seals, e.g. to DIN 11851, Cherry Burrell, APC connection, Tri-clamp connection, etc. The sanitary remote seals are common designs in the food industry. Their design means that the measured medium cannot accumulate in dead volumes. The sanitary clamp present on the remote seal means that quick dismounting is possible for cleaning. • Button diaphragm seal with male thread for screwing into tapped holes. • Remote seals with customer-specific process connections. © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Technical description Clamp-on seals The following types of clamp-on seals exist: • Sanitary inline seals, e.g. to DIN 11851, Cherry Burrell, triclamp connection etc. The sanitary facility enables the seal to be removed quickly for cleaning purposes. • Inline seals for positioning between DIN or ANSI flanges. • Inline seals with customer-specific process connections. ■ Transmission response Temperature errors occur if the fill fluid in the remote seal and in the capillaries expands or contracts as a result of temperature effects. The temperature error depends on the diaphragm charateristic, the influence of the fill fluid, and the influence of the fill fluid under the process flanges or in the flanges on the transmitter (volume minimized for remote seals). Diaphragm characteristic The charateristic of the remote seal is of great importance. The larger the diaphragm diameter, the softer it is. In comparison to a smaller diaphragm, this means that it can respond far easier to temperature-based expansions of the filling liquid. The result is that low measuring ranges are only possible with large diaphragm diameters. In addition, the diaphragm thickness, its material, and any coatings which may be present must also be considered. Fill fluid All fill fluids expand or contract when the temperature varies. Temperature-independent errors can be minimized by selecting a suitable filling liquid, but it must also be ensured that the filling liquid is appropriate for the temperature limits and operating pressure. For food and beverage as well as pharmaceutical applications see reference for FDA approved fill fluids. Since the fill fluid is present under the remote seal diaphragm, in the capillaries and under the process flanges of the transmitter, the temperature error must be calculated separately for each combination. Response time The response time depends on the internal diameter of the capillaries, the viscosity of the filling liquid, the capillary extension length, and the pressure in the measuring system: Internal diameter: The response time decreases as the internal diameter increases, but the temperature error increases due to increased oil volume. Viscosity: The response time increases as the viscosity increases. Capillary length: The capillary length has a proportional effect on the response time and the temperature error. Measuring system pressure: The response time decreases as the pressure in the measuring system increases. ■ Recommendations The following should be observed to obtain an optimum combination of transmitter and remote seal: • The remote seal diameter, and thus the effective diameter of the diaphragm, should be selected as large as possible in order to keep the temperature-dependents errors as low as possible. • The capillaries should be selected as short as possible in order to keep the response time and the temperature-dependent errors as low as possible. Button diaphragm seal with diaphragm flush with front Sanitary tri-clamp seal and for flange pancake mounting • A filling liquid should be selected which has the lowest viscosity and the lowest coefficient of expansion, and which simultaneously fulfills the process requirements with respect to pressure/vacuum and temperature. The filling liquid must also be compatible with the process medium. • When installing the equipment for vacuum applications, the transmitter must always be located below the lowest tap. • It should also be noted that some of the filling liquids are very limited with respect to the permissible temperature of the medium for vacuum applications. • When operating permanently at a vacuum, the remote seal must be designed in the version resistant to those vacuum applicaton. • Recommendations on the minimum span can be found in the tables on pages 1/208 and 1/209. ■ Note The remote seals listed in this catalog are a selection of the most common designs. As a result of the large variety of process connections, it may nevertheless be the case that certain remote seals which are not listed in the catalog are still available. Other versions could be: • Other process connections, standards • Aseptic or sterile connections • Other sizes • Other nominal pressures • Special diaphragm materials, including coatings • Other sealing faces • Other fill fluids • Other capillary lengths • Sheathing of capillaries with protective coat • Calibration at higher/lower temperatures etc. Please contact your Siemens Regional Office for more information. Siemens FI 01 · 2015 US Edition 1/207 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Technical description ■ Technical specifications Nominal diameter, nominal pressure, pressure connection See Ordering data Sealing face (only for pancake and flanged remote seals) To ANSI B16.5 RF 250 RMS for stainless steel or solid materials or ANSI B16.5 RFSF (smooth finish) for other materials Materials • Main body for pancake and flange remote seals • Wetted parts materials • Housing and diaphragm for Inline seals • Capillary • Armor Stainless steel, mat. No. 1.4435/316L See Ordering data Stainless steel, mat. No. 1.4435/ 316L or stainless steel, 7MF4880-... and 7MF4883-... Stainless steel, mat. No. 1.4571/316Ti Spiral sheath made of stainless steel, mat. No. 304 Sealing material in the transmitter pressure flanges • For absolute pressure transmitters and vacuum applications • For other applications Max. pressure Capillary • Length Copper Viton See nominal pressure of remote seal and transmitter • Internal bore • Smallest bending radius Max. 30 ft. longer lengths on inquiry 0.079 inch 6.0 inch Fill fluid • For pancake and flange remote seals • For sanitary remote seals See Ordering data Neobee M20 or glycerine/water Ambient temperature See transmitter and filling liquid Certificates and approvals Classification according to pressure equipment directive (DGRL 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) ■ Measuring errors based on physical properties always result when using remote seals Temperature errors of diaphragm seals when connected to pressure, absolute pressure or level transmitters, and with single-sided connection to differential pressure transmitters Nominal diameter/ design Flange to ANSI B16.5 Flange to DIN 2501 Sanitary Tri-Clamp Button Seal 2" flush flanged 2" with extension 3" flush flanged 3" with extension 4" flush flanged 4" with extension 5" flush flanged 5" with extension DN 50 flush flanged DN 50 with extension DN 80 flush flanged DN 80 with extension DN 100 flush flanged DN 100 with extension DN 125 flush flanged DN 125 with extension 1 ½" 2" 2 ½" 3" 4" 1 NPT-male 1 ½ NPT-male 2" NPT-male Effective diaphragm diameter [in] 2.32 1.89 3.5 2.83 3.5 3.5 4.88 4.88 2.32 1.89 3.5 2.83 3.5 3.5 4.88 4.88 1.26 1.57 2.32 2.83 3.5 0.98 1.57 2.05 Temperature error Temperature error Temperature error of remote seal of capillary of transmitter [inH2O/25 °F] [inH2O/25 °F/3 ft] flange connection [inH2O/25 °F] 1.69 2.04 2.04 2.81 5.1 5.1 0.23 0.21 0.21 0.58 0.53 0.53 0.23 0.21 0.21 0.23 0.21 0.21 0.12 0.07 0.07 0.12 0.07 0.07 1.69 2.04 2.04 2.81 5.1 5.1 0.23 0.21 0.21 0.58 0.53 0.53 0.23 0.21 0.21 0.23 0.21 0.21 0.12 0.07 0.07 0.12 0.07 0.07 9.51 35.73 35.73 3.93 7.67 7.67 1.69 2.57 2.57 0.58 0.53 0.53 0.23 0.21 0.21 13.97 81.7 81.7 3.93 7.67 7.67 2.23 2.57 2.57 Temperature errors of diaphragm seals (part 1) Remarks: • Values apply to fill fluid: silicone oil DC 200, high-temperature oil, halocarbon oil and Neobee M20. • Values apply to stainless steel as the diaphragm material. 1/208 Siemens FI 01 · 2015 US Edition Recommended values, min. spans (observe temperature error) [psi] 7.5 7.5 1.5 3.5 1.5 1.5 0.3 0.3 7.5 7.5 1.5 3.5 1.5 1.5 0.3 0.3 60 30 7.5 3.5 1.5 90 30 7.5 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Technical description Temperature errors of diaphragm seals with double-sided connection to differential pressure transmitters Nominal diameter/ design Flange to ANSI B16.5 Flange to DIN 2501 Sanitary Tri-Clamp 2" flush flanged 2" with extension 3" flush flanged 3" with extension 4" flush flanged 4" with extension 5" flush flanged 5" with extension DN 50 flush flanged DN 50 with extension DN 80 flush flanged DN 80 with extension DN 100 flush flanged DN 100 with extension DN 125 flush flanged DN 125 with extension 2" 2 ½" 3" 4" Effective diaphragm diameter [in] 2.32 1.89 3.5 2.83 3.5 3.5 4.88 4.88 2.32 1.89 3.5 2.83 3.5 3.5 4.88 4.88 1.57 2.32 2.83 3.5 Temperature error Temperature error Temperature error of remote seal of capillary of transmitter [inH2O/25 °F] [inH2O/25 °F/3 ft] flange connection [inH2O/25 °F] 0.384 0.42 0.42 0.692 1.051 1.051 0.077 0.042 0.042 0.154 0.126 0.126 0.077 0.042 0.042 0.077 0.042 0.042 0.038 0.017 0.017 0.038 0.017 0.017 0.384 0.42 0.42 0.692 1.051 1.051 0.077 0.042 0.042 0.154 0.126 0.126 0.077 0.042 0.042 0.077 0.042 0.042 0.038 0.017 0.017 0.038 0.017 0.017 0.961 1.849 1.849 0.384 0.42 0.42 0.154 0.126 0.126 0.077 0.042 0.042 Recommended values, min. spans (observe temperature error) [psi] 3.5 3.5 1 1.5 1 1 0.3 0.3 3.5 3.5 1 1.5 1 1 0.3 0.3 30 3.5 1.5 1 Temperature errors of diaphragm seals (part 2) Remarks: • Values apply to fill fluids: silicone oil DC 200, high-temperature oil, halocarbon oil and Neobee M20. • Values apply to stainless steel as the diaphragm material. Temperature errors of clamp-on seals when connected to pressure or absolute pressure transmitters, and with single-sided connection to differential pressure transmitters Nominal diameter/design 1 inch 1 ½ inch 2 inch 3 inch 4 inch Temperature error of remote seal [inH2O/25 °F] 3.345 2.499 2.23 5.305 0.461 Temperature error of capillary [inH2O/25 °F/3 ft] 5.17 2.732 1.849 3.068 1.849 Temperature error of transmitter flange connection [inH2O/25 °F] 5.17 2.732 1.849 3.068 1.849 Recommended values, min. spans (observe temperature error) [psi] 14.5 3.5 1.5 1.5 1.5 Temperature errors of clamp-on seals with double-sided connection to differential pressure transmitters Nominal diameter/design 1 inch 1 ½ inch 2 inch 3 inch 4 inch Temperature error of remote seal [inH2O/25 °F] 1.269 0.461 0.154 1.692 0.577 Temperature error of capillary [inH2O/25 °F/3 ft] 1.093 0.168 0.084 0.294 0.084 Temperature error of transmitter flange connection [inH2O/25 °F] 1.093 0.168 0.084 0.294 0.084 Recommended values, min. spans (observe temperature error) [psi] 14.5 3.5 1.5 1.5 1.5 Temperature errors of clamp-on seals Remarks: • Values apply to fill fluids: silicone oil DC 200, high-temperature oil, halocarbon oil and Neobee M20. • Values apply to stainless steel as the diaphragm material. • Diaphragm thickness: 1" & 1 ½" & 2":0.002 inch 3" & 4": 0.004 inch Siemens FI 01 · 2015 US Edition 1/209 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Technical description Calculation of temperature error for remote seals Dependence of temperature error on diaphragm material The following equation is used to calculate the temperature error for remote seals: The errors listed in the tables on pages 1/208 and 1/209 refer to the use of stainless steel as the diaphragm material. If a different material is used, the listed values change by the amount shown in the following table. dp = (tRS - tCal) . fRS + (tCap - tCal) . lCap . fCap + (tTR - tCal) . fPF dp Additional temperature error (inH2O) Diaphragm material tRS Temperature on remote seal diaphragm (generally corresponds to temperature of medium) Change in temperature error of remote seal Stainless steel tCal Reference (calibration) temperature 68 °F Values as specified in tables on pages 1/208 and 1/209 fRS Temperature error of remote seal (see tables on pages 1/208 and 1/209) Hastelloy C4, mat. No. 2.4610 Increase in values by 50% Hastelloy C276, mat. No. 2.4819 Increase in values by 50% Monel 400, mat. No. 2.4360 Increase in values by 60% Tantalum Increase in values by 50% Titanium Increase in values by 50% Teflon lining on stainless steel diaphragm Increase in values by 120% Halar coating or PFA coating on stainless steel diaphragm Increase in values by 100% Example of calculation of temperature error for remote seals Existing conditions: Gold coating on stainless steel diaphragm Increase in values by 40% tCap Ambient temperature on the capillaries lCap Capillary extension length (error given per 3 ft) fCap Temperature error of capillaries (see tables on pages 1/208 and 1/209) tTR Ambient temperature on transmitter fPF Temperature error of oil filling in process flanges of transmitter (see tables on pages 1/208 and 1/209) SITRANS P transmitter for differential pressure, 100 inH2O, set to 0 to 40 inH2O with 3 in flush flanged remote seal, diaphragm made of stainless steel, mat. No. 1.4535/316L fRS = 0.054 inH2O/25 °F Capillary 2 x 15 ft lCap = 2 x 15 ft Capillaries fitted on both sides fCap= 0.042 inH2O/25 °F/3 ft Filled with silicone oil DC 200-10 fPF = 0.042 inH2O/25 °F Temperature of medium 212 °F tRS = 212 °F Temperature on capillaries 122 °F tCap = 122 °F Temperature on transmitter 122 °F tTR = 122 °F Response times (approximate) Required: Additional temperature error of remote seal: dp Calculation: dp = (212 °F – 68 °F) . 0.077 inH2O/25 °F + (122 °F – 68 °F) . 15 ft . 2 . 0.042 inH O/25 °F / 3ft + (122 °F – 68 °F) . 0.042 inH O/25 °F 2 2 dp = 0.444 inH2O + 0.907 inH2O + 0.091 inH2O Result: dp = 1.442 inH2O (corresponds to 3.605 % of set span) Note: The temperature error determined above only applies to the error resulting from connection of the remote seal. The transmission response of the respective transmitter is not included in this consideration. It must be calculated separately, and the resulting error added to the error determined above from connection of the remote seal. 1/210 Siemens FI 01 · 2015 US Edition The listed values are the response times (in seconds, per meter of capillary extension) for a change in pressure which corresponds to the set span. The listed values must be multiplied by the respective length of the capillary extension, or with transmitters for differential pressure and flow by the total length of both capillary extensions. The response times are independent of the set span within the range of the respective transmitter. The response times are of insignificant importance for spans above 145 psi (10 bar). The response time of the transmitter has not been considered. © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Technical description Filling liquid Density Temperature on capillary Response time in s/m (s/ft) with max. span of transmitter kg/dm3 (lb/in3) °C (°F) 250 mbar (3.63 psi) 600 mbar (8.7 psi) 1600 mbar (23.2 psi) Silicone oil DC 200-10 0.934 (0.033) +60 +20 - 20 (140) (68) (-4) 0.06 0.11 0.3 (0.018) (0.034) (0.091) 0.02 0.02 0.12 (0.006) (0.006) (0.037) 0.01 0.02 0.05 (0.003) (0.006) (0.015) Silicone oil DC 200-50 0.966 (0.035) +60 +20 - 20 (140) (68) (-4) 0.6 0.61 1.69 (0.183) (0.186) (0.515) 0.25 0.26 0.71 (0.076) (0.079) (0.216) 0.09 0.1 0.27 (0.027) (0.030) (0.082) Syltherm 800 0.935 (0.034) +60 +20 - 20 (140) (68) (-4) 0.06 0.11 0.3 (0.018) (0.034) (0.091) 0.02 0.02 0.12 (0.006) (0.006) (0.37) 0.01 0.02 0.05 (0.003) (0.006) (0.015) High-temperature oil 1.07 (0.039) +60 +20 -10 (140) (68) (14) 0.14 0.65 3.96 (0.043) (0.198) (1.207) 0.06 0.27 1.65 (0.018) (0.082) (0.503) 0.02 0.1 0.62 (0.006) (0.030) (0.189) Halocarbon oil 1.968 (0.071) +60 +20 - 20 (140) (68) (68) 0.07 0.29 2.88 (0.021) (0.088) (0.878) 0.03 0.12 1.2 (0.009) (0.037) (0.366) 0.01 0.05 0.45 (0.003) (0.015) (0.137) Fluorolube 1.866 (0.068) +60 +20 - 20 (140) (68) (68) 0.07 0.29 2.88 (0.021) (0.088) (0.878) 0.03 0.12 1.2 (0.009) (0.037) (0.366) 0.01 0.05 0.45 (0.003) (0.015) (0.137) Neobee M20 0.917 (0.033) +60 +20 - 20 (140) (68) (68) 0.18 0.43 1.19 (0.055) (0.131) (0.363) 0.08 0.18 0.5 (0.024) (0.055) (0.152) 0.03 0.07 0.18 (0.009) (0.021) (0.055) Glycerine/water 1.22 (0.044) +60 +20 0 (140) (68) (32) 0.13 0.76 9.72 (0.040) (0.232) (2.963) 0.05 0.32 4.05 (0.015) (0.098) (12.34) 0.02 0.12 1.51 (0.006) (0.037) (0.460) ■ Technical specifications of filling liquid When selecting the filling liquid, check that it is suitable with respect to the permissible temperature of the medium and the process pressure. Also check the compatibility with the measured medium. For example, only food grade filling liquids may be used in the food industry. A special case are oxygen and chlorine as the measured media; the fill fluid must not react with them, otherwise an explosion or fire may occur if there is a leak in the remote seal. Filling liquid Permissible temperature of medium Density at 20 °C (68 °F) pabs<1 bar (pabs<14.5 psi) pabs>1 bar (pabs>14.5 psi) kg/dm3 (lb/in3) °C (°F) °C (°F) Silicone oil DC200-10 Silicone oil DC 200-50 Syltherm 800 -40 to +121 (-40 to +248) -40 to +200 (-40 to +392) 0.934 -20 to +150 (-4 to +302) -20 to +250 (-4 to +482) -40 to +121 (-40 to +250) -40 to +205 High-temperature oil Halocarbon oil -10 to +200 (+14 to +392) -10 to +350 -40 to +80 (-40 to +176) Fluorolube Not possible Not possible Neobee M20 10 to +90 Glycerine/water Not possible Viscosity at 20 °C (68 °F) Expansion coefficient m2/s·106 (ft2/s·106) 1/°C (1/°F) (0.03) 10 (107.6) 0.00108 (0.00060) 0.96 (0.03) 50 (538) 0.00104 (0.00058) (-40 to +400) 0.935 (0.034) 10.03 (107.9) 0.00109 (0.00061) (+14 to +662) 1.07 (0.04) 39 (420) 0.0008 (0.00044) -40 to +175 (-40 to +347) 1.968 (0.07) 14 (151) 0.00086 (0.00048) -40 to +175 (-40 to +347) 1.866 (0.068) 15.5 (167) 0.000864 (0.00048) (+14 to +195) -10 to +200 (+14 to +392) 0.917 (0.03) 9.8 (105) 0.00082 (0.00045) Not possible -10 to +120 (+14 to +248) 1.22 (0.04) 88 (947) 0.0005 (0.00028) ■ Maximum temperature of medium ■ Maximum capillary length (guidance values for diaphragm seals and inline seals) The following maximum temperatures of the medium apply depending on the wetted parts materials: Material Stainless steel, mat. No. 1.4571/316Ti PTFE coating ECTFE/PFA coating Hastelloy C4, mat. No. 2.4610 Hastelloy C276, mat. No. 2.4819 Monel 400, mat. No. 2.4360 Tantalum pabs < 1 bar (14.5 psi) Nominal diameter pabs > 1 bar (14.5 psi) Max. length of capillary Diaphragm seal Inline seal DN 25 (1 inch) 2.5 m (8.2 ft) 2.5 m (8.2 ft) °C (°F) °C (°F) DN 32 (1¼ inch) 2.5 m (4.9 ft) 2.5 m (8.2 ft) 200 100 100 200 200 200 200 (392) (212) (212) (392) (392) (392) (392) 350 150 150 350 350 350 300 (662) (302) (302) (662) (662) (662) (572) DN 40 (1½ inch) 4m (13.1 ft) 6m (19.7 ft) DN 50 (2 inch) 6m (19.7 ft) 10 m (32.8 ft) DN 65 (2½ inch) 8m (26.2 ft) 10 m (32.8 ft) DN 80 (3 inch) 10 m (32.8 ft) 10 m (32.8 ft) Size 4 inch (30.0 ft) – Size 5 inch (30.0 ft) – Siemens FI 01 · 2015 US Edition – 1/211 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Pancake type diaphragm seal with flexible capillary tube ■ Overview Selection and Ordering data Article No. Order code Pancake type diaphragm seal with flexible capillary extension, connected to a SITRANS P transmitter (order separately) for pressure 7MF40 7 7 or 7MF42 7 7 7MF4800- for absolute pressure 7MF43 7 7 7MF4801- for differential pressure 7MF44 7 7 • dual seals for DP 7MF48031 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. • 2 inch class 150 ... 2500 • 3 inch class 150 ... 2500 • 4 inch class 150 ... 2500 • 5 inch class 150 ... 2500 Special design, customer information to be supplied Pancake type diaphragm seal ■ Dimensions (Connection to ASME B16.5) This area (A) is to be coated with teflon (PFA) to a minimum thickness of 0.004" No foreign liquids or material are to enter these openings A A 1 System fill port A DM D Pancake type diaphragm seal, dimensions Size Class 2" 3" 4" 5" 150 - 2500 D DM F A [in2] 3.94 2.32 0.79 12.2 5.28 3.50 0.79 21.9 6.22 3.50 0.79 30.4 7.32 4.80 0.87 42.1 Size = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 All dimensions in inches unless otherwise noted 1/212 Siemens FI 01 · 2015 US Edition Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Extension length (316SS standard) Without extension (standard version) Special design, customer information to be supplied for extension System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer inform. to be supplied Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer inform. to be supplied E H L N Z J1Y A E0 G J K Z K1J 0 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code for 7MF4800 Integrated flame path restriction Certificate of calibration N.I.S.T. (20% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A01 C11 C12 V01 Y05 for 7MF4801 Integrated flame path restriction Certificate of calibration N.I.S.T. (20% steps) Material conformance certificate Calculation of span of transmitter (completed questionnaire to be attached) A01 C11 C12 Y05 for 7MF4803 Integrated flame path restriction Certificate of calibration N.I.S.T. (20% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A02 C11 C12 V03 Y05 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Flange-type diaphragm seal directly connected ■ Overview Size Class A B C DM E F G X Weight DN ½" ¾" 1" 1.5" Flange-type diaphragm seal, without extension 2" ■ Dimensions (connection to ASME B16.5) Optional instrument Welded capillary connection 1/4” NPT 1/2“ NPT 3" lbs 150 3.50 2.38 1.38 1.3 0.85 0.06 0.62 4 2.2 300 3.75 2.62 1.38 1.6 0.85 0.06 0.62 4 2.2 150 3.88 2.75 1.69 1.6 0.85 0.06 0.62 4 2.4 300 4.62 3.25 1.69 1.6 0.85 0.06 0.75 4 3.5 150 4.25 3.12 2.00 2.1 0.85 0.06 0.62 4 3.1 300 4.88 3.50 2.00 2.1 0.85 0.06 0.75 4 3.7 150 5.00 3.55 2.88 1.9 0.69 0.06 0.62 4 3.5 300 6.12 4.50 2.88 1.9 0.81 0.06 0.88 4 5.5 600 6.12 4.50 2.88 1.9 1.13 0.25 0.88 4 7.3 1500 7.00 4.88 2.88 1.9 1.50 0.25 1.12 4 13.0 2500 8.00 5.75 2.88 1.9 2.00 0.25 1.25 4 22.9 150 6.00 4.75 3.62 2.4 0.75 0.06 0.75 4 5.9 300 6.50 5.00 3.62 2.4 0.88 0.06 0.75 8 8.1 600 6.50 5.00 3.62 2.4 1.25 0.25 0.75 8 12.5 1500 8.50 6.50 3.62 2.4 1.75 0.25 1.00 8 29.0 2500 9.25 6.75 3.62 2.4 2.25 0.25 1.12 8 43.6 150 7.50 6.00 5.00 3.5 0.94 0.06 0.75 4 11.7 300 8.25 6.62 5.00 3.5 1.12 0.06 0.88 8 17.2 600 8.25 6.62 5.00 3.5 1.50 0.25 0.88 8 24.2 900 9.50 7.50 5.00 3.5 1.75 0.25 1.00 8 36.7 1500 10.53 8.00 5.00 3.5 2.13 0.25 1.25 8 53.9 2500 12.01 9.00 5.00 3.5 2.87 0.25 1.38 8 93.9 9.00 7.50 6.19 3.5 0.94 0.06 0.75 8 16.9 300 10.04 7.88 6.19 3.5 1.25 0.06 0.88 8 27.9 400 10.4 7.88 6.19 3.5 1.63 0.25 1.00 8 38.3 600 10.83 8.50 6.19 3.5 1.75 0.25 1.00 8 47.3 900 11.51 9.25 6.19 3.5 2.00 0.25 1.25 8 60.9 1500 12.30 9.50 6.19 3.5 2.37 0.25 1.38 8 81.4 2500 14.00 10.75 6.19 3.5 3.25 0.25 1.62 8 144.5 150 4" Flange-type diaphragm seal without extension for flanges 1" DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted Flange-type diaphragm seal, without extension, dimensions System fill port Optional instrument connections welded capillary connection 1/4” NPT 1/2“ NPT Flange-type diaphragm seal without extension for flanges 1.5" Siemens FI 01 · 2015 US Edition 1/213 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Flange-type diaphragm seal with extension ■ Overview Selection and Ordering data Article No. Order code Flange-type diaphragm seal directly connected to a SITRANS P 7MF40 7 7 or 7MF42 7 7 (order separately) 7MF481077777 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process connection vertical (transmitter upright) horizontal Size and class • 2 inch class 150 • 2 inch class 300 • 2 inch class 600 • 2 inch class 1500 • 3 inch class 150 • 3 inch class 300 • 3 inch class 600 • 4 inch class 150 • 4 inch class 300 • 4 inch class 400 Special design, customer information to be supplied Flange-type diaphragm seal, with extension ■ Dimensions Instrument connection Options Welded capillary connection 1/4” NPT 1/2“ NPT Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Extension length (316SS standard) Without extension (standard version) 2" 4" 6" 8" Special design, customer information to be supplied for extension System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Size Class A B C DM E1) F G H X L DN 2" 150 6.00 4.75 300 6.50 5.00 3" 150 7.50 6.00 300 8.25 6.62 4" 150 9.00 7.50 300 10.04 7.88 3.62 1.8 1.90 5.00 2.8 2.99 6.19 3.5 3.70 0.75 0.75 4 0.88 0.75 8 0.94 1.12 0.06 0.75 4 0.88 8 0.94 0.75 8 1.25 0.88 8 1) based on schedule 40 DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted Flange-type diaphragm seal, with extension, dimensions 1/214 Siemens FI 01 · 2015 US Edition 2.0 3.0 4.0 6.0 0 2 L M N P Q R S T U V Z J1Y A E0 G J K Z K1Y 0 1 2 3 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certification of calibration N.I.S.T. (20% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A01 B01 C11 C12 V01 Y05 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Flange-type diaphragm seal with extension Selection and Ordering data Article No. Order code Selection and Ordering data 7MF4812- Mounting flange at High-Side, Flange-Type Seal, w/o extension Flange-type seal via capillary extension on low-side without extension Mounting flange directly mounted at SITRANS P for Level 7MF46 7 7 (order separately) 3 7777 777 for SITRANS P for differential pressure 7MF44 7 7 (order separately) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Flange Size ANSI B16.5 2 inch Class 150 300 150 3 inch 300 150 4 inch 300 Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Extension length (316SS standard) Without extension (standard version, 0 mm) 2" 50 mm 4" 100 mm 6" 150 mm 8" 200 mm Special design, customer information to be supplied for extension System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied 7MF48131 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. L M Q R T U Z J1Y A E0 G J K Z K1Y 0 1 2 3 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certificates: Certification of calibration N.I.S.T. (20% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Article No. Order code A0 1 B0 1 C1 C1 V0 Y0 1 2 4 5 Flange Size ANSI B16.5 2 inch Class 150 300 150 3 inch 300 150 4 inch 300 Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Extension length (316SS standard) Without extension (standard version, 0 mm) 2" 50 mm 4" 100 mm 6" 150 mm 8" 200 mm Special design, customer information to be supplied for extension System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied L M Q R T U Z J1Y A E G J K Z K1Y 0 1 2 3 4 9 L1Y 1 2 3 4 5 6 7 8 9 Capillary length at low-side • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied M1 Y 2 3 4 5 6 7 8 9 Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Rotatable Flange Certification of calibration N.I.S.T. (20% steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Siemens FI 01 · 2015 US Edition A0 B0 C1 C1 V0 Y0 2 1 1 2 4 5 1/215 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Diaphragm seal "flanged off-line low-pressure type", directly connected ■ Overview DM = Effective diaphragm diameter G1 = Instrument connection G2 = Process connection G3 = Threaded bolt hole X = Number of bolt holes Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal "flanges off-line low-pressure type" ■ Dimensions (Connection to ASME B16.5) Instrument connection options welded capillary connection 1/4” NPT 1/2“ NPT Size ½" ½" ½" ¾" ¾" ¾" 1" 1" 1" 1 ½" 1 ½" 1 ½" 2" 2" 2" G2 Class 150# 300# 600# 150# 300# 600# 150# 300# 600# 150# 300# 600# 150# 300# 600# 1/216 G3 X ½"-13UNC ½"-13UNC ½"-13UNC ½"-13UNC 5 /8"-11UNC 5 /8"-11UNC ½"-13UNC 5/ "-11UNC 8 5 /8"-11UNC ½"-13UNC ¾"-10UNC ¾"-10UNC 5/ "-11UNC 8 5/ "-11UNC 8 5 /8"-11UNC 4 4 4 4 4 4 4 4 4 4 4 4 4 8 8 A B 5.91 5.91 5.91 5.91 5.91 5.91 5.91 5.91 5.91 5.91 5.91 6.12 6.12 6.00 6.50 6.50 Siemens FI 01 · 2015 US Edition C 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 DM E 3.5 2.36 2.36 2.55 2.36 2.36 2.55 2.36 2.36 2.55 2.36 2.46 2.65 2.36 2.36 2.55 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line low-pressure type", directly connected Selection and Ordering data Article No. Order code Diaphragm seal "flanged off-line low-pressure type" direct mount to transmitter, 316 stainless steel upper housing SITRANS P for 7MF44 7 7 or 7MF46 7 7 (order separately) 7MF48143 7777 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • ½ inch class 150#RF • ½ inch class 300#RF • ½ inch class 600#RF • ¾ inch class 150#RF • ¾ inch class 300#RF • ¾ inch class 600#RF • 1 inch class 150#RF • 1 inch class 300#RF • 1 inch class 600#RF • 1 ½ inch class 150#RF • 1 ½ inch class 300#RF • 1 ½ inch class 600#RF • 2 inch class 150#RF • 2 inch class 300#RF • 2 inch class 600#RF Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) 2 x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied A B C E F G J K L N P Q S T U Z J1Y A E G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) A0 1 Material conformance certificate C1 2 Vacuum service (must be specified with HT oil) V01 Calculation of span of transmitter (completed questionnaire to be attached) Y05 C1 1 Siemens FI 01 · 2015 US Edition 1/217 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Flange-type diaphragm seal with flexible capillary tube ■ Overview ■ Connection to ASME B16.5 Size Class A B C DM E F G X Weight DN ½" ¾" 1" 1.5" Flange-type diaphragm seal with flexible capillary extension 2" ■ Dimensions (Connection to ASME B16.5) Optional instrument Welded capillary connection 1/4” NPT 1/2” NPT 3" lbs 150 3.50 2.38 1.38 1.3 0.85 0.06 0.62 4 2.2 300 3.75 2.62 1.38 1.6 0.85 0.06 0.62 4 2.2 150 3.88 2.75 1.69 1.6 0.85 0.06 0.62 4 2.4 300 4.62 3.25 1.69 1.6 0.85 0.06 0.75 4 3.5 150 4.25 3.12 2.00 2.1 0.85 0.06 0.62 4 3.1 300 4.88 3.50 2.00 2.1 0.85 0.06 0.75 4 3.7 150 5.00 3.55 2.88 1.9 0.69 0.06 0.62 4 3.5 300 6.12 4.50 2.88 1.9 0.81 0.06 0.88 4 5.5 600 6.12 4.50 2.88 1.9 1.13 0.25 0.88 4 7.3 1500 7.00 4.88 2.88 1.9 1.50 0.25 1.12 4 13.0 2500 8.00 5.75 2.88 1.9 2.00 0.25 1.25 4 22.9 150 6.00 4.75 3.62 2.4 0.75 0.06 0.75 4 5.9 300 6.50 5.00 3.62 2.4 0.88 0.06 0.75 8 8.1 600 6.50 5.00 3.62 2.4 1.25 0.25 0.75 8 12.5 1500 8.50 6.50 3.62 2.4 1.75 0.25 1.00 8 29.0 2500 9.25 6.75 3.62 2.4 2.25 0.25 1.12 8 43.6 150 7.50 6.00 5.00 3.5 0.94 0.06 0.75 4 11.7 300 8.25 6.62 5.00 3.5 1.12 0.06 0.88 8 17.2 600 8.25 6.62 5.00 3.5 1.50 0.25 0.88 8 24.2 900 9.50 7.50 5.00 3.5 1.75 0.25 1.00 8 36.7 1500 10.53 8.00 5.00 3.5 2.13 0.25 1.25 8 53.9 2500 12.01 9.00 5.00 3.5 2.87 0.25 1.38 8 93.9 9.00 7.50 6.19 3.5 0.94 0.06 0.75 8 16.9 300 10.04 7.88 6.19 3.5 1.25 0.06 0.88 8 27.9 400 10.4 7.88 6.19 3.5 1.63 0.25 1.00 8 38.3 600 10.83 8.50 6.19 3.5 1.75 0.25 1.00 8 47.3 900 11.51 9.25 6.19 3.5 2.00 0.25 1.25 8 60.9 1500 12.30 9.50 6.19 3.5 2.37 0.25 1.38 8 81.4 2500 14.00 10.75 6.19 3.5 3.25 0.25 1.62 8 144.5 150 4" Flange-type diaphragm seal for flanges 1" System fill port Optional instrument connections welded capillary connection 1/4” NPT 1/2” NPT Flange-type diaphragm seal for flanges .5" 1/218 Siemens FI 01 · 2015 US Edition DN = Nominal pipe size DM = Effective diaphragm diameter Class = Flange rating per ASME B16.5 X = Number of bolt holes All dimensions in inches unless otherwise noted © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Flange-type diaphragm seal with flexible capillary tube Selection and Ordering data Article No. Order code Flange-type diaphragm seal for pressure 7MF40 7 7 or 7MF42 7 7 7MF4820- for absolute pressure 7MF43 7 7 7MF4821- for differential pressure 7MF44 7 7 • dual seals for DP 7MF48231 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Extension length (316SS standard) Without extension (standard version) Special design, customer information to be supplied for extension System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied Order code Further designs Please add „-Z“ to Article No. and specifiy Order code with flexible capillary extension, connected to a SITRANS P transmitter (order separately) Size and class • 2 inch class 150 • 2 inch class 300 • 2 inch class 600 • 2 inch class 1500 • 3 inch class 150 • 3 inch class 300 • 3 inch class 600 • 4 inch class 150 • 4 inch class 300 • 4 inch class 400 • 5 inch class 150 • 5 inch class 300 • 5 inch class 400 Special design, customer information to be supplied Selection and Ordering data L M N P Q R S T U V W X Y Z J1Y A E0 G J K Z for 7MF4820 Integrated flame path restriction Rotatable Flange DP "H" flange service Certificate of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A01 B01 B02 C11 C12 V01 Y05 for 7MF4821 Integrated flame path restriction Rotatable Flange Certificate of calibration N.I.S.T. (20 % steps) Material conformance certificate Calculation of span of transmitter (completed questionnaire to be attached) A01 B01 C11 C12 Y05 for 7MF4823 Integrated flame path restriction Rotatable Flange Certificate of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A02 B01 C11 C12 V03 Y05 K1Y 0 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 2 3 4 5 6 7 8 9 N1Y Siemens FI 01 · 2015 US Edition 1/219 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Diaphragm seal "flanged off-line type" ■ Overview G1 ¼"-NPT or ½"-NPT G1 ½" ½" ½" 1" 1" 1" 1 ½" 1 ½" 1 ½" 2" 2" 2" G2 150# 300# 600# 150# 300# 600# 150# 300# 600# 150# 300# 600# G2 G3 4 x ½"-13UNC 4 x ½"-13UNC 4 x ½"-13UNC 4 x ½"-13UNC 4 x 5/8"-11UNC 4 x 5/8"-11UNC 4 x ½"-13UNC 4 x ¾"-10UNC 4 x ¾"-10UNC 4 x 5/8"-11UNC 8 x 0.75 8 x 0.75 A 3.75 3.75 3.75 4.25 4.88 4.88 5.00 6.12 6.12 6.00 6.50 6.50 B 2.38 2.62 2.62 3.12 3.50 3.50 3.88 4.50 4.50 4.75 5.00 5.00 G3 F H C ½" 150# 4 x ½"-13UNC 1.10 0.06 ½" 300# 4 x ½"-13UNC 1.10 0.06 ½" 600# 4 x ½"-13UNC 1.26 0.25 1" 150# 4 x ½"-13UNC 0.87 0.06 1" 300# 4 x 5/8"-11UNC 0.87 0.06 ¼"-NPT 1" 600# 4 x 5/8"-11UNC 1.26 0.25 or ½"-NPT 1 ½" 150# 4 x ½"-13UNC 0.87 0.06 1 ½" 300# 4 x ¾"-10UNC 0.87 0.06 1 ½" 600# 4 x ¾"-10UNC 1.26 0.25 2" 150# 4 x 5/8"-11UNC 0.87 0.06 2" 300# 8 x 0.75 0.89 0.06 2" 600# 8 x 0.75 1.28 0.25 DM = Effective diaphragm diameter G1 = Instrument connection G2 = Process connection G3 = Threaded bolt hole All dimensions in inches unless otherwise noted Instrument connection System fill port Diaphragm seal "flanged off-line type", dimensions Instrument connection System fill port Optional 1/8” NPT or 1/4” NPT flushing connection 1/220 Siemens FI 01 · 2015 US Edition E 2.1 3.74 1.38 2.00 2.88 3.62 J Diaphragm seal "flanged off-line type" ■ Dimensions (Connection to ASME B16.5) DM 2.20 2.20 2.36 1.97 1.97 2.36 1.97 1.97 2.36 1.97 1.99 2.38 Weight lbs 4.3 4.3 4.4 4.4 8.5 8.5 5.0 6.6 9.1 6.1 8.5 10.0 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line type" Selection and Ordering data Article No. Order code Diaphragm seal "flanged off-line type" MAWP depends on flange with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF40 7 7 and 7MF42 7 7 (order separately) 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Seal design Stud mount All-welded stud mount Through-hole flange mount Size and class • ½ inch class 150#RF • ½ inch class 300#RF • ½ inch class 600#RF • ¾ inch class 150#RF • ¾ inch class 300#RF • ¾ inch class 600#RF • 1 inch class 150#RF • 1 inch class 300#RF • 1 inch class 600#RF • 1 ½ inch class 150#RF • 1 ½ inch class 300#RF • 1 ½ inch class 600#RF • 2 inch class 150#RF • 2 inch class 300#RF • 2 inch class 600#RF Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) 2 x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil (comes with metal gasket and stronger bolts) • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied 1 2 3 A B C E F G J K L N P Q S T U Z Article No. Order code Further designs Please add „-Z“ to Article No. and specifiy Order code 7MF482677777 - 7B Selection and Ordering data Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 B0 C1 C1 V0 Y0 1 2 1 2 1 5 J1Y A E G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Siemens FI 01 · 2015 US Edition 1/221 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Diaphragm seal "flanged off-line low-pressure type" ■ Overview Diaphragm seal "flanged off-line low-pressure type" ■ Dimensions (Connection to ASME B16.5) Instrument connection options welded capillary connection 1/4” NPT 1/2“ NPT 1/222 Siemens FI 01 · 2015 US Edition G2 G3 X A B Size Class ½" 150# ½"-13UNC 4 5.91 ½" 300# ½"-13UNC 4 5.91 ½" 600# ½"-13UNC 4 5.91 ¾" 150# ½"-13UNC 4 5.91 5/ "-11UNC ¾" 300# 4 5.91 8 5/ "-11UNC ¾" 600# 4 5.91 8 1" 150# ½"-13UNC 4 5.91 5/ "-11UNC 1" 300# 4 5.91 5.91 8 5 1" 600# /8"-11UNC 4 5.91 1 ½" 150# ½"-13UNC 4 5.91 1 ½" 300# ¾"-10UNC 4 6.12 1 ½" 600# ¾"-10UNC 4 6.12 5/ "-11UNC 2" 150# 4 6.00 8 5/ "-11UNC 2" 300# 8 6.50 8 5 2" 600# /8"-11UNC 8 6.50 DM = Effective diaphragm diameter G2 = Process connection G3 = Threaded bolt hole X = Number of bolt holes Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted C 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 0.06 0.06 0.25 DM E 3.5 2.36 2.36 2.55 2.36 2.36 2.55 2.36 2.36 2.55 2.36 2.46 2.65 2.36 2.36 2.55 Diaphragm seal "flanged off-line low-pressure type", dimensions © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "flanged off-line low-pressure type" Selection and Ordering data Article No. Order code Diaphragm seal "flanged off-line low-pressure type" with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF40 7 7 and 7MF42 7 7 (order separately) Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) 2 x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied 7MF48271 7777 - 7B 777 with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF44 7 7 (order separately) 7MF48281 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. A B C E F G J K L N P Q S T U Z J1Y A E G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Size and class • ½ inch class 150#RF • ½ inch class 300#RF • ½ inch class 600#RF • ¾ inch class 150#RF • ¾ inch class 300#RF • ¾ inch class 600#RF • 1 inch class 150#RF • 1 inch class 300#RF • 1 inch class 600#RF • 1 ½ inch class 150#RF • 1 ½ inch class 300#RF • 1 ½ inch class 600#RF • 2 inch class 150#RF • 2 inch class 300#RF • 2 inch class 600#RF Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female (available w/ SS, HC or MO) 2 x ¼"NPT-female (available w/ SS, HC or MO) Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied A B C E F G J K L N P Q S T U Z J1Y A E G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied M1 Y 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Article No. Order code Diaphragm seal "flanged off-line low-pressure type" Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • ½ inch class 150#RF • ½ inch class 300#RF • ½ inch class 600#RF • ¾ inch class 150#RF • ¾ inch class 300#RF • ¾ inch class 600#RF • 1 inch class 150#RF • 1 inch class 300#RF • 1 inch class 600#RF • 1 ½ inch class 150#RF • 1 ½ inch class 300#RF • 1 ½ inch class 600#RF • 2 inch class 150#RF • 2 inch class 300#RF • 2 inch class 600#RF Special design, customer information to be supplied Selection and Ordering data A0 B0 C1 C1 V0 Y0 1 2 1 2 1 5 Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Siemens FI 01 · 2015 US Edition A0 C1 C1 V0 Y0 2 1 2 1 5 1/223 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Flushing rings ■ Overview ■ Technical specifications Flushing ring for remote seals of pancake and flange design Nom. diam. • DN 50 • DN 80 • DN 100 • DN 125 Nom. press. PN 16 ... PN 100 PN 16 ... PN 100 PN 16 ... PN 100 PN 16 ... PN 100 • 2 inch • 3 inch • 4 inch • 5 inch Class 150 ... class 600 Class 150 ... class 600 Class 150 ... class 600 Class 150 ... class 600 Sealing face Flushing ring • To EN 1092-1 Form B1 Form B2 Form D/Form D Form C/Form C Form C/Form C Form E Form F • To ASME B16.5 RF 125 ... 250 AA RFSF RJT ring groove Flushing holes (2 off), female thread: • G¼ • G½ Flushing rings are required for flange-mounted and pancake type remote seals (Article No. 7MF4800 ... 7MF4823) if the danger exists that the process conditions and the geometry of the connection could cause the process to form deposits or blockages. The flushing ring is clamped between the process flange and the remote seal. Deposits can be flushed away from the diaphragm through the holes in the side, or the pressure volume can be vented. Different nominal diameters and forms permit adaptation to the respective process flange. • ¼-18 NPT Process connection • ½-14 NPT For flanges to EN and ASME: DN 50, 80, 100, 125; PN 16 ... 100 or DN 2 inch, 3 inch, 4 inch, 5 inch; Class 150 ... 600 Stainless steel 1.4404/316L Material ■ Dimensional drawings Standard design Thread Material: CrNi-Stahl, mat. No. 1.4404/316L Sealing faces and flushing holes: See Ordering data ■ Design h 1 Remote seal flange Flushing ring di d4 Flushing outlet Gasket Measuring point flange Installation example Flushing inlet Connection to EN 1092-1 DN PN d4 di h Weight (mm) (bar) (mm) (mm) (mm) (kg) 50 16 ... 100 102 62 30 1.10 80 16 ... 100 138 92 30 1.90 100 16 ... 100 162 92 30 3.15 125 16 ... 100 188 126 30 3.50 Connection to ASME B 16.5 DN inch Class d4 mm di Siemens FI 01 · 2015 US Edition Weight (inch) mm (inch) mm (inch) kg (lb) 2 150 ... 600 92 (3.62) 62 (2.44) 30 (1.18) 0.60 (1.32) 3 150 ... 600 127 (5) 92 (3.62) 30 (1.18) 1.05 (2.31) 4 150 ... 600 157 (6.18) 92 (3.62) 30 (1.18) 2.85 (6.28) 5 150 ... 600 185.5 (7.3) 126 (4.96) 30 (1.18) 3.30 (7.28) Flushing ring, dimension drawing 1/224 h © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Flushing rings Selection and Ordering data Article No. Ord. code Flushing ring 7MF4825- for remote seals 7MF4900 to 7MF4923 1 7777 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Nom. diam. Nom. press. • 2 inch • 3 inch • 4 inch • 5 inch Class 150 ... 600 Class 150 ... 600 Class 150 ... 600 Class 150 ... 600 Other version Add Order code and plain text: Nominal diameter: ...; Nominal pressure: ... Sealing face • ASME B16.5 - RF 125 ... 250 AA - RFSF - RJT ring groove Other version Add Order code and plain text: Sealing face: ... Flushing holes (2 off) • Female thread G¼ • Female thread G½ • Female thread ¼-18 NPT • Female thread ½-14 NPT Material • Stainless steel 316L Other version Add Order code and plain text: Material: ... G H J K Z J1Y M Q R Z K1Y 1 2 3 4 0 9 M1 Y Further designs Please add „-Z“ to Article No. and specifiy Order code Acceptance test certificate B to EN 10204, section 3.1.B C1 2 Siemens FI 01 · 2015 US Edition 1/225 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Diaphragm seal with quick connection ■ Overview ■ Overview Diaphragm seal with quick connection, with slotted union nut ■ Dimensions (connection to ASME B16.5) Diaphragm seal with quick connection, Tri-Clamp connection ■ Dimensions (connection to ASME B16.5) Type 7MF4840 with union nut DN MAWP A [mm] [psi] [mm] 25 600 Rd 52 x 1/6 32 600 Rd 58 x 1/6 40 600 Rd 65 x 1/6 50 360 Rd 78 x 1/6 B C DM E 2.48 2.76 3.07 3.62 0.83 0.83 0.83 0.87 1.0 1.3 1.6 2.1 2.36 2.72 2.17 2.32 G1 Weight [lbs] 1.3 ¼"-NPT 1.6 or ½"-NPT 2.5 female 2.8 Diaphragm seal with quick connection, with slotted union nut Type 7MF4840 with male thread DN MAWP A [mm] [psi] [mm] 40 600 Rd 65 x 1/6 50 360 Rd 78 x 1/6 B C 3.07 1.12 3.62 1.42 DM E 1.6 2.1 2.17 2.24 G1 Weight [lbs] ¼"-NPT 2.8 or 3.0 ½"-NPT female DM = Effective diaphragm diameter MAWP = Maximum Working Pressure @ 250 °F G1 = Instrument connection DN = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, with male thread, dimensions 1/226 Siemens FI 01 · 2015 US Edition Size MAWP A B C DM E G1 Weight [in] [psi] [lbs] 1.5 600 1.50 1.97 1.71 1.0 1.3 ¼"-NPT 2 550 1.50 2.52 2.22 1.6 1.7 or 2.5 450 2.52 3.05 2.78 2.0 1.38 2.0 ½"-NPT 3 350 2.31 3.58 3.28 2.8 2.4 female 4 250 2.31 4.68 4.34 3.5 2.7 DM = Effective diaphragm diameter MAWP = Maximum Working Pressure @ 250 °F, higher rating with appropriate clamping device G1 = Instrument connection Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, Tri-Clamp connection, dimensions © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Inline diaphragm seal with quick connection ■ Overview Selection and Ordering data Article No. Order code Diaphragm seal with quick connection for gage pressure transmitter SITRANS P 7MF40 7 7 and 7MF42 7 7 (order separately) 7MF484077 A 0 7 - 7B 777 made of 316 SS Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process connection DIN 11 851 with slotted union nut DN 25/PN 40 DN 32/PN 40 DN 40/PN 40 DN 50/PN 25 DN 65/PN 25 DN 80/PN 25 Diaphragm seal with quick connection, "i"-line (Cherry Burrel - male) ■ Dimensions (connection to ASME B16.5) DIN 11 851 with screw necks DN 25/PN 40 DN 32/PN 40 DN 40/PN 40 DN 50/PN 25 DN 65/PN 25 DN 80/PN 25 Tri-Clamp Connection 1 ½" 600 psi 2" 550 psi 2 ½" 450 psi 3" 350 psi Varivent (Tuchenhagen) Size 25132 Size 40150 Sanitary (4" Tank Spud) 2" extension 6" extension "I"-Line (Cherry Burrell - male) 1 ½" 500 psi 2" 450 psi 3" 350 psi Special design, customer information to be supplied System fill • Vegetable oil • Glycerin/Water 86.5/13.5 % • Neobee M20 • Mineral oil Special design, customer information to be supplied Size MAWP A B C [in] [psi] 1.5 500 1.18 2.00 2 450 1.42 1.18 2.64 3 350 1.30 3.87 DM 1.3 1.8 2.8 E F 1.74 1.38 2.24 1.44 3.30 1.59 G1 Weight [lbs] ¼"-NPT 1.3 or 1.7 ½"-NPT 2.4 female DM = Effective diaphragm diameter MAWP = Maximum Working Pressure @ 250 °F, higher rating with appropriate clamping device G1 = Instrument connection Size = Nominal pipe size All dimensions in inches unless otherwise noted Diaphragm seal with quick connection, "i"-line (Cherry Burrel - male), dimensions 1B 1C 1D 1E 1F 1G 2B 2C 2D 2E 2F 2G 4L 4M 4N 4P 5C 5E 6B 6D 5U 5V 5W 9Z H1Y +J1Y 1 2 3 4 9 Length of capillary • Direct Mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C11 C12 V01 Y05 Tank Spud accessories Sanitary Tank Spud Clamp (1 pc.) Sanitary Tank Spud O-ring (1 pc.) Sanitary Tank Spud Weldolet 2" extension (1 pc.) Sanitary Tank Spud Weldolet 6" extension (1 pc.) Siemens FI 01 · 2015 US Edition P10 P11 P12 P13 1/227 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Inline diaphragm seal with quick connection Selection and Ordering data Article No. Order code Diaphragm seal with quick connection for differential transmitter SITRANS P 7MF44 7 7 (order separately) made of 316 SS 7MF484377 A 0 7 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process connection DIN 11 851 with slotted union nut DN 50/PN 25 DN 65/PN 25 DN 80/PN 25 DIN 11 851 with screw necks DN 50/PN 25 DN 65/PN 25 DN 80/PN 25 Tri-Clamp Connection 2" 550 psi 2 ½" 450 psi 3" 350 psi 4" 250 psi "I"-Line (Cherry Burrell - male) 3" 350 psi 4" 200 psi Sanitary (4" Tank Spud) 2" extension 6" extension Special design, customer information to be supplied System fill • Vegetable oil • Glycerin/Water 86.5/13.5 % • Neobee M20 • Mineral oil Special design, customer information to be supplied Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied 1E 1F 1G 2E 2F 2G 4M 4N 4P 4Q 5W 5X 6B 6D 9Z H1Y +J1Y 1 2 3 4 9 M1 Y 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C11 C12 V03 Y05 Tank Spud accessories Sanitary Tank Spud Clamp (1 pc., two required) P10 Sanitary Tank Spud O-ring (1 pc., two required) P11 Sanitary Tank Spud Weldolet 2" extension (1 pc., two required) P12 Sanitary Tank Spud Weldolet 6" extension (1 pc., two required) P13 1/228 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Inline diaphragm seal with quick connection ■ Overview ■ Overview Inline diaphragm seal with quick connector, DIN 11851 with thread Inline diaphragm seal with quick connection, Tri-clamp ■ Dimensions (connection to ASME B16.5) DN MAWP A B C E G H J L [mm] [psi] 15 600 Rd34x1/8 1.10 1.57 0.71 0.12 0.16 0.47 4.1 25 600 Rd52x1/6 1.50 2.05 1.18 0.14 0.28 0.55 5.0 40 600 Rd65x1/6 2.17 2.56 1.65 0.14 0.28 0.55 6.3 50 360 Rd78x1/6 2.68 3.07 2.13 0.14 0.28 0.55 6.7 65 360 Rd95x1/6 3.35 3.74 2.80 0.14 0.31 0.63 7.2 80 360 Rd110x1/4 4.33 4.33 3.35 0.14 0.31 0.79 7.2 100 360 Rd130x1/4 5.12 5.12 4.09 0.16 0.39 0.79 7.2 MB = Internal diameter MAWP = Maximum Working Pressure @ 250 °F, higher rating with appropriate clamping device DN = Nominal pipe size All dimensions in inches unless otherwise noted ■ Dimensions (connection to ASME B16.5) MB 0.63 1.02 1.50 1.97 2.60 3.19 3.94 Inline diaphragm seal with quick connector, DIN 11851 with thread, dimensions Size MAWP A B C E L MB [psi] ¾" 600 0.7 1.34 0.8 0.98 3.8 0.6 1" 600 1.4 1.97 1.7 1.97 4.5 1.0 1.5" 600 1.7 1.97 1.7 1.97 5.7 1.5 2" 550 2.2 2.50 2.2 2.50 6.1 1.9 2.5" 450 2.7 3.10 2.8 3.10 6.1 2.4 3" 350 3.2 3.60 3.3 3.60 6.1 2.9 3.5" 350 3.7 4.20 3.8 4.20 6.1 3.3 4" 250 4.3 4.70 4.3 4.70 6.1 3.8 MB = Internal diameter MAWP = Maximum Working Pressure @ 250 °F, higher rating with appropriate clamping device Size = Nominal pipe size All dimensions in inches unless otherwise noted Inline diaphragm seal with quick connection, Tri-clamp, dimensions Siemens FI 01 · 2015 US Edition 1/229 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Inline diaphragm seal with quick connection ■ Overview Selection and Ordering data Article No. Order code Inline diaphragm seal with quick connection for transmitter SITRANS P for 7MF40 7 7 and 7MF42 7 7 (order separately) made of 316 SS 7MF485077 A 0 7 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Inline diaphragm seal with quick connection, "i"-Line (Cherry Burrell - male/male) ■ Dimensions (connection to ASME B16.5) Process connection DIN 11 851 with thread [C] DN 25/PN 40 DN 40/PN 40 DN 50/PN 25 DN 65/PN 25 DN 80/PN 25 DN100/PN 25 Tri-Clamp Connection 1" 600 psi 1 ½" 600 psi 2" 550 psi 2 ½" 450 psi 3" 350 psi "I"-Line (Cherry Burrell - male/male) 1" 500 psi 1 ½" 500 psi 2" 450 psi 3" 350 psi Special design, customer information to be supplied System fill • Vegetable oil • Glycerin/Water 86.5/13.5 % • Neobee M20 • Mineral oil Special design, customer information to be supplied Size MAWP A B C E H L MB [psi] 1.5" 500 1.68 1.97 1.74 2.00 0.203 4.79 1.38 2" 450 2.25 2.50 2.24 2.64 0.258 5.54 1.88 2.5" 350 2.75 3.10 2.74 3.31 0.312 6.38 2.37 MB = Internal diameter MAWP = Maximum Working Pressure @ 250 °F, higher rating with appropriate clamping device Size = Nominal pipe size All dimensions in inches unless otherwise noted Inline diaphragm seal with quick connection, "i"-Line (Cherry Burrell male/male), dimensions 1/230 Siemens FI 01 · 2015 US Edition Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied 2B 2D 2E 2F 2G 2H 4K 4L 4M 4N 4P 5R 5U 5V 5W 9Z H1Y +J1Y 1 2 3 4 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with vegetable oil) Calculation of span of transmitter (completed questionnaire to be attached) C11 C12 V03 Y05 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "threaded design" ■ Overview G1 G2 A B DM E F ¼"-NPT or 1.18 2.1 2.20 0.63 ½"-NPT 3.74 ¾"-NPT 1.41 2.1 2.36 0.79 1"-NPT 1.77 2.1 3.46 1.89 G1 = Instrument connection, G2 = Process connection DM = Effective diaphragm diameter All dimensions in inches unless otherwise noted ¼"-NPT or ½"-NPT Weight [lbs] 3.0 3.4 3.6 Diaphragm seal "threaded design" Selection and Ordering data Diaphragm seal "threaded design" MAWP 3675 psi with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF407 7 and 7MF42 7 7 pressure (order separately) Article No. Order code 7MF48611 7777 - 7B Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Diaphragm seal "threaded design" ■ Dimensions (Connection to ASME B16.5) Instrument connection Size and class • ¼"NPT-female • ½"NPT-female • ¾"NPT-female • 1"NPT-female Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • SST 316L with Hastelloy C276 diaphragm • SST 316L with PFA coated diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C276 lower housing with Tantalum diaphragm Special design, customer inform. to be supplied System fill port Process connection Instrument connection System fill port Flushing port(s) None 1 x ¼"NPT-female 2 x ¼"NPT-female Special design, customer inform. to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil (comes with metal gasket and stronger bolts) • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer inform. to be supplied A B C D Z J1Y A E F D G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer inform. to be supplied Optional 1/8” NPT or 1/4” NPT flushing connection 777 Process connection M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specify Order code Integrated flame path restriction DP "H" flange service Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) Siemens FI 01 · 2015 US Edition A0 B0 C1 C1 V0 Y0 1 2 1 2 1 5 1/231 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "threaded, low-pressure design" ■ Overview Selection and Ordering data Article No. Order code Diaphragm seal "threaded, low-pressure design" MAWP 1,500 psi with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF407 7 and 7MF42 7 7 pressure (order separately) 7MF48621 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • ¼"NPT-female • ½"NPT-female • ¾"NPT-female • 1"NPT-female Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm1) • SST 316L with Hastelloy C276 diaphragm • SST 316L with PFA coated diaphragm • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C276 lower housing with Tantalum diaphragm Special design, customer information to be supplied Diaphragm seal "threaded, low-pressure design" ■ Dimensions (Connection to ASME B16.5) A B G1 Flushing port(s) None 1 x ¼"NPT-female 2 x ¼"NPT-female Special design, customer information to be supplied E System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil (comes with metal gasket and stronger bolts) • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied F 1 Process connection G2 C DM Diaphragm seal "threaded, low-pressure design, dimensions G1 G2 A B C DM ¼"-NPT 1.25 ¼"-NPT ½"-NPT 1.25 or 5.91 4.92 3.5 1.38 ½"-NPT ¾"-NPT 1"-NPT 1.75 G1 = Instrument connection G2 = Process connection DM = Effective diaphragm diameter All dimensions in inches unless otherwise noted 1/232 Siemens FI 01 · 2015 US Edition E F 3.00 3.00 3.20 3.50 0.90 0.90 1.10 1.40 Weight [lbs] 14.0 14.0 14.2 14.5 Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied A B C D Z J1Y A E F D G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 C1 C1 V0 Y0 1 1 2 1 5 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal "threaded, low-pressure design" Selection and Ordering data Article No. Order code Diaphragm seal "threaded, low-pressure design" MAWP 1,500 psi with flexible armored capillary, 316 stainless steel upper housing SITRANS P for 7MF44 7 7 (order separately) 7MF48631 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • ¼"NPT-female • ½"NPT-female • ¾"NPT-female • 1"NPT-female Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • SST 316L with Hastelloy C276 diaphragm • SST 316L with PFA coated diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Hastelloy C276 lower housing with Tantalum diaphragm Special design, customer information to be supplied Flushing port(s) None 1 x ¼"NPT-female 2 x ¼"NPT-female Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil (comes with metal gasket and stronger bolts) • Halocarbon (for O2-application) • Silicone oil M5 • Syltherm 800 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied A B C D Z J1Y A E F D G J K Z K1Y 0 2 4 9 L1Y 1 2 3 4 5 6 7 8 9 M1 Y 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 C1 C1 V0 Y0 2 1 2 3 5 Siemens FI 01 · 2015 US Edition 1/233 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Inline diaphragm seal, wafer for pressure ■ Overview Selection and Ordering data Article No. Order code Inline diaphragm seals wafer assembled to SITRANS P for 7MF40 7 7 and 7MF42 7 7 (order separately) 7MF48801 77 0 7 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • 1 inch class 150 to 2500 • 1 ½ inch class 150 to 2500 • 2 inch class 150 to 2500 • 3 inch class 150 to 2500 • 4 inch class 150 to 2500 Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with PFA-Coating (good up to 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Inline diaphragm seal, wafer for pressure ■ Dimensions (Connection to ASME B16.5) System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Optional instruments connections welded capillary connection 1/4” NPT 1/2” NPT Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied Size Class A MB 1" 2.4 1.12 1.5" 3.3 1.69 2" 3.7 2.15 3" 150# - 2500# 5.1 3.25 4" 5.9 4.21 5" 7.3 5.20 6" 8.5 6.26 MB = Effective internal diameter Class = Flange rating per ASME B16.5 Size = Nominal pipe size All dimensions in inches unless otherwise noted L 2.36 Inline diaphragm seal, wafer for pressure, dimensions 1/234 Siemens FI 01 · 2015 US Edition Weight [lbs] 3.1 4.8 5.5 8.8 10.3 15.0 20.9 L M N P Q Z J1Y A D G J K Z K1Y 1 2 3 4 5 7 8 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 C1 C1 V0 Y0 1 1 2 1 5 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Inline diaphragm seal, wafer for pressure Selection and Ordering data Article No. Order code Inline diaphragm seals wafer assembled to SITRANS P for 7MF44 7 7 (order separately) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Size and class • 1 inch class 150 to 2500 • 1 ½ inch class 150 to 2500 • 2 inch class 150 to 2500 • 3 inch class 150 to 2500 • 4 inch class 150 to 2500 Special design, customer information to be supplied Materials and wetted parts • SST 316L • SST 316L with PFA-Coating (good up to 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil • Halocarbon (for O2-application) • Silicone oil M5 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied 7MF48831 77 0 7 - 7B L M N P Q Z 777 J1Y A D G J K Z K1Y 1 2 3 4 5 7 8 9 M1 Y 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 C1 C1 V0 Y0 2 1 2 3 5 Siemens FI 01 · 2015 US Edition 1/235 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Diaphragm seal, saddle ■ Overview ■ Dimensions (Connection to ASME B16.5) Radius To fit Pipe R Pipe size O.D. 1.49 2.5 3.00 1.77 3.0 3.50 2.24 4.0 4.50 2.76 5.0 5.50 3.35 6.0 6.63 4.311 8.0 8.625 5.374 10.0 10.75 6.378 12.0 12.75 7.0 14.0 14.75 G1 = Instrument connection All dimensions in inches unless otherwise noted G1 ¼"-NPT or ½"-NPT female Diaphragm seal, saddle, dimensions Diaphragm seal, saddle Saddle flange Clamp ring Upper housing Spacer ring Adapter GTAW 1/236 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Diaphragm seal, saddle Selection and Ordering data Article No. Order code Diaphragm seal, saddle, MAWP 1,500 psi with flexible armored capillary or direct mount, 316 stainless steel upper housing and assemply hardware SITRANS P for 7MF40 7 7 or 7MF42 7 7 (order separately) 7MF48901 7777 - 7B 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Nominal pipe size • Not applicable (Retrofit for existing 7MF48 7 7) • 2.5" • 3" • 4" • 5" • 6" • 8" • Retrofit 3" Conoflow (6 bolt pattern) • Retrofit 3" M&G style (8 bolt pattern) • Retrofit 4" Conoflow (6 bolt pattern) • Retrofit 4" M&G style (8 bolt pattern) Special design, customer information to be supplied Diaphragm material • SST 316L • SST 316L with carbon pigmented Teflon lined diaphragm (good upto 500 °F) • SST 316L with PFA coated diaphragm (good upto 500 °F) • Monel 400, mat. No. 2.4360 • Hastelloy C276, mat. No. 2.4819 • Tantal Special design, customer information to be supplied Saddle Material None (Retrofit order) Carbon steel, Ni plated SST 316L Hastelloy C276, mat. No. 2.4819 Special design, customer information to be supplied System fill • Silicone oil DC 200-10 • Silicone oil DC 200-50 • High temperature oil (comes with metal gasket and stronger bolts) • Halocarbon (for O2-application) • Silicone oil M5 • DC704 silicone oil • Fluorolube Special design, customer information to be supplied Length of capillary • Direct mount • 3 ft • 5 ft • 10 ft • 15 ft • 20 ft • 25 ft • 30 ft Special design, customer information to be supplied N A B C D E G P Q R S Z J1Y A E D G J K Z K1Y 0 1 2 4 9 L1Y 1 2 3 4 5 7 8 9 M1 Y 0 2 3 4 5 6 7 8 9 N1Y Further designs Please add „-Z“ to Article No. and specifiy Order code Integrated flame path restriction Certification of calibration N.I.S.T. (20 % steps) Material conformance certificate Vacuum service (must be specified with HT oil) Calculation of span of transmitter (completed questionnaire to be attached) A0 C1 C1 V0 Y0 1 1 2 1 5 Siemens FI 01 · 2015 US Edition 1/237 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Measuring setups ■ Measuring setups The following pages show examples of typical measuring setups for use of SITRANS P transmitters with and without remote seals, such as: • Setups for transmitters with connection of remote seals, with associated equations for calculation. • Questionnaires Checking of combination between transmitter and remote seal • Setups for transmitters without remote seals, with associated equations for calculation • Questionnaires For hydrostatic level measurements ■ Installation Remote seals of pancake design are fitted between the connection flange of the measuring point and a blind flange. Remote seals of flanged design are fitted directly on the connection flange of the measuring point. The respective pressure rating of the blind flange or the flanged remote seal must be observed. The transmitter should always be installed below the connection flange, and below the lower connection flange in the case of differential pressure transmitters. When measuring at pressures above atmospheric, the transmitter can also be installed above the connection flange. When measuring at pressures below atmospheric, the transmitter must always be installed below the connection flange, and below the lower connection flange in the case of differential pressure transmitters. ■ Influence of ambient temperature The capillaries between the remote seal and the transmitter should be kept as short as possible to obtain the good transmission response. Temperature differences between the individual capillaries or between the individual remote seals should be avoided. If the complete setup is exposed to temperature variations, errors result from the thermal expansion of the filling liquid in the capillaries, in the remote seals and in the connection units of the transmitters. ■ Notes • When measuring separation layers, ensure that the layer is positioned between the two spigots. Also ensure that the level in the vessel is always above the top spigot. • When measuring density, make sure that the level of the medium remains constant. The level is usually above the top spigot. ■ Possible combinations of transmitter and remote seal Installation type Transmitter Remote seal A/B 7MF4033 and 7MF4034 7MF4800, 7MF4810, 7MF4820, 7MF4826, 7MF4827, 7MF4840, 7MF4850, 7MF4861, 7MF4862, 7MF4880 and 7MF4890 C1/C2 7MF4233 and 7MF4234 7MF4800, 7MF4810, 7MF4820, 7MF4826, 7MF4827, 7MF4840, 7MF4850, 7MF4861, 7MF4862, 7MF4880 and 7MF4890 7MF4333 and 7MF4334 7MF4801 and 7MF4821 D 7MF4433, 7MF4434, 7MF5403 and 7MF5413 7MF4803, 7MF4823, 7MF4828, 7MF4843, 7MF4863 and 7MF4883 E 7MF4433, 7MF4434, 7MF5403 and 7MF5413 7MF4813 G/H/J 7MF4433, 7MF4434, 7MF5403 and 7MF5413 7MF4803, 7MF4823, 7MF4828, 7MF4843, 7MF4863 and 7MF4883 ■ Offset of measuring range If there is a difference in height between the two connection flanges when measuring with two remote seals, an additional differential pressure results from the oil filling of the remote seal capillaries. This results in an offset of the actual measuring range and must be taken into account when adjusting the transmitter. An offset in the measuring range also occurs when combining a remote seal with a transmitter if the latter is not installed at the same height as the former. ■ Transmitter output If the level, separation layer or density increase in closed vessels, the differential pressure and the output signal of the transmitter also increase. If an inverted relationship is desired between the differential pressure and the output signal, the start-ofscale and full-scale values of the SITRANS P must be interchanged. With open vessels, an increasing pressure is usually assigned to an increasing level, separation layer or density. 1/238 Siemens FI 01 · 2015 US Edition (vacuum-proof design required) 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Measuring setups with remote seals ■ Schematics Types of installation for pressure and level measurements (open vessels) Installation type A Installation type B Installation type A Start-of-scale: pMA = ρFL · g · HU - ρOil · g · H1 Full-scale: ∆H ∆H Installation type B HO HO pME = ρFL · g · HO - ρOil · g · H1 Start-of-scale: pMA = ρFL · g · HU + ρOil · g · H1 HU Full-scale: HU H1 pME = ρFL · g · HO + ρOil · g · H1 Legend H1 Pressure transmitter above the measuring point Pressure transmitter below the measuring point H1 ≤ 7 m (23 ft), with halocarbon oil as filling liquid only H1 ≤ 4 m (13.1 ft) pMA Start-of-scale value to be set pME Full-scale value to be set ρFL Density of medium in vessel ρOil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value H1 Distance between vessel flange and pressure trans. Types of installation for absolute level measurements (closed vessels) Installation type C2 Installation type C1 Installation type C1 and C2 Start-of-scale: pMA = pSTART + ρOil · g · H1 Full-scale: pME = pEND + ρOil · g · H1 Legend H1 Start-of-scale value to be set pMA pabs pabs H1 pME Full-scale value to be set pSTART Start-of-scale value pEND Full-scale value ρOil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity H1 Distance between vessel flange and pressure trans. Pressure transmitter for absolute pressure always below the measuring point: H1 ≥ 200 mm (7.9 inch) Type of installation for differential pressure and flow measurements Installation type D Filter monitoring Installation type D Start-of-scale: pMA = pSTART - ρOil · g · HV Full-scale: pME = pEND - ρOil · g · HV Legend H1 HV H2 + pMA Start-of-scale value to be set pME Full-scale value to be set pSTART Start-of-scale value pEND Full-scale value ρOil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity HV Distance between the measuring points (spigots) - Siemens FI 01 · 2015 US Edition 1/239 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Measuring setups with remote seals Types of installation for level measurements (closed vessels) Installation type E Installation type E Start-of-scale: pMA = ρFL · g · HU - ρOil · g · HV Full-scale: pME = ρFL · g · HO - ρOil · g · HV Legend ∆H HV HO HU Installation type G Installation type H - Start-of-scale value to be set Full-scale value to be set ρFL Density of medium in vessel ρOil Density of filling oil in the capillary to the remote seal g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value HV Distance between the measuring points (spigots) - + H2 pMA pME Installation type J + H1 H1 ∆H HV HO - H1 + H2 HU H2 + below the lower measuring point Pressure transmitter for differential pressure above the upper measuring point, no vacuum Installation type for vacuum applications H1 ≤ 7 m (23 ft), with halocarbon oil as filling liquid only H1 ≤ 4 m (13.1 ft) between the measuring points, no vacuum H2 ≤ 7 m (23 ft), with halocarbon oil as filling liquid only H2 ≤ 4 m (13.1 ft) Installation type G, H and J Legend Start-of-scale: pMA = ρFL · g · HU - ρOil · g · HV pMA Start-of-scale value to be set g Full-scale: pME Full-scale value to be set HU Start-of-scale value ρFL Density of medium in vessel HO Full-scale value ρOil Density of filling oil in the capillary to the remote seal HV Distance between the measuring points (spigots) 1/240 pME = ρFL · g · HO - ρOil · g · HV Siemens FI 01 · 2015 US Edition Local acceleration due to gravity © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges Measuring setups without remote seals ■ Overview Notes • For the separation layer measurement, the separation layer has to be positioned between the two spigots. Also you must make sure that the level in the container is always above the top spigot. • When measuring density, make sure that the level of the medium remains constant. The level should be above the top spigot ■ Schematics Pressure transmitters for differential pressure, for flanging Measuring setups for open containers Level measurement Full-scale value Start-of-scale: pMA = ρ · g · HU Full-scale: pME = ρ · g · HO Legend pMA HO Start-of-scale value ρ HU Start-of-scale value to be set pME Full-scale value to be set ρ Density of medium in vessel g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value + Separation layer measurement Constant level = full-scale value Start-of-scale: pMA = g · (HU · ρ1 + (HO - HU) · ρ2) Full-scale: ρ2 Legend Separation layer ρ1 HO pME = ρ1 · g · HO Start-of-scale value HU + pMA Start-of-scale value to be set pME Full-scale value to be set ρ1 Density of heavier liquid ρ2 Density of lighter liquid g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value Density measurement Start-of-scale: pMA = ρMIN · g · HO Constant level Full-scale: pME = ρMAX · g · HO Legende pMA HO ρ Start-of-scale value to be set pME Full-scale value to be set ρMIN Minimum density of medium in vessel ρMAX Maximum density of medium in vessel g Local acceleration due to gravity HO Full-scale value in m + Siemens FI 01 · 2015 US Edition 1/241 1 © Siemens AG 2015 Pressure Measurement Remote seals for transmitters and pressure gauges 1 Measuring setups without remote seals Measuring setups for closed containers Level measurement, Version 1 Static pressure Start-of-scale: ∆pMA = ρ · g · HU Gas-filled negative pressure line Full-scale: ∆pME = ρ · g · HO Legend Maximum level Full-scale value Start-of-scale value HO HU ∆pMA Start-of-scale value to be set ∆pME Full-scale value to be set ρ Density of medium in vessel g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value ρ + - Transmitter reference line Level measurement, Version 2 Static pressure Start-of-scale: ∆pMA = g · (HU · ρ - HV · ρ') Constant reference level Full-scale: ∆pME = g · (HO · ρ - HV · ρ') Legend Mamimum level Liquid-filled negative pressure line Full-scale value Start-of-scale value ρ' ρ + Start-of-scale value to be set ∆pME Full-scale value to be set ρ Density of medium in vessel ρ' Density of liquid in the negative pressure line (corresponding to the temperature existing there) HV HO HU ∆pMA - g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value HV Distance between the measuring points (spigots) Transmitter reference line Separation layer measurement Static pressure Static pressure Constant level Start-of-scale: ∆pMA = g · (HU · ρ1 + (HO - HU) · ρ2 - HV · ρ'2) Full-scale: Max. separation layer ∆pME = g · (HO · ρ1 - HV · ρ'2) Legend ∆pMA Full-scale value Start-of-scale value ρ'2 ρ2 HU ρ1 - Transmitter reference line Siemens FI 01 · 2015 US Edition Density of heavier liquid with separation layer in vessel ρ2 Density of lighter liquid with separation layer ρ'2 Density of liquid in the negative pressure line (corresponding to the temperature existing there) + 1/242 Full-scale value to be set ρ1 HV HO Start-of-scale value to be set ∆pME g Local acceleration due to gravity HU Start-of-scale value HO Full-scale value HV Distance between the measuring points (spigots) © Siemens AG 2015 s Questionnaire (suitable for US market) for hydrostatic level measurements 1 Order date: _______________________________________________ Processing date: __________________________________________ Ordering code (customer): _________________________________ Ordering code (supplier): __________________________________ Customer reference:_______________________________________ Measuring point: __________________________________________ Position:__________________________________________________ Dimensions: ______________________________________________ Pressure: psi Temperature: K Measuring range: inch (please mark with cross) °F ft Article No. of transmitter SITRANS P DS III/P3001): 7 M F 4 – – –Z Y01 Article No. of transmitter SITRANS P5001): 0 7 M F 5 – The different pressures and temperatures (densities) in the vessel and in the reference column result in an offset in the start-of-scale and full-scale values. The calibration data are determined in addition. It is also checked whether – as a result of the range offset – the ordered transmitter is suitable for this measurement. Please supply the following characteristic data so that we can calculate the measuring range, start-of-scale value, full-scale value and calibration data: Please mark type of boiler with a cross: Closed1) Open or not under pressure2) Medium ____________________ Licensed boiler pressure (absolute) Operating pressure (absolute) _______________ psi Lowest Normal _______________ psi 3) _______________ psi Highest _______________ psi Temperature of reference column (cold) _______________ °F Distance between measuring points (dimension according to sketch) HV = _________ ft Measuring range4) = start-of-scale value to full-scale value Start-of-scale value HU =___________ ft Full-scale value HO =___________ ft Position of equalizing vessel above bottom measuring point if different from HV Please mark pressure correction of level with a cross: _______________ ft No Yes4) 1) 2) 3) 4) Reference line filled with condensation! Falling differential pressure with increasing level. Reference line without gas or filled with gas (air). Rising differential pressure with increasing level. If not specified otherwise, this value is assumed as the calculation pressure of the level meter. The input signal (differential pressure) depends on the density (pressure and temperature). The influence is practically negligible for a lowest liquid level of 20 to 30% of the distance between the measuring points. If a pressure correction of the level is required, the measuring range must be the same as the distance between the measuring points, and the transmitter is designed for the calculation pressure of 14.5 psi (absolute). Pressure correction means: the static pressure and the temperature are measured separately and calculated by a correction computer or measured-value computer. Siemens FI 01 · 2015 US Edition 1/243 © Siemens AG 2015 s Questionnaire (suitable for US market) Checking of transmitter/remote seal combinations 1 * Customer:___________________ Tag. No.: _____________________ * Plant: ___________________ Item No.: _____________________ * Ordering code:________________ Person responsible: ___________ * Ordering department: _____ Phone: _____________________ * Transmitter Article No. SITRANS P DS III/P300: 7MF –1 Y * Transmitter Article No. SITRANS P500: 7MF5 – 0 –Z –1 V00 Article No. of diaphragm seal known? Yes No * Article No. of remote seal: * 7MF 4 9 – – –Z Suffixes _______________________ Suffixes _______________________ * Or without Article No.: Process connection * Standard: ________________________ * Nominal diameter: ________________________ * Nominal pressure: ________________________ * Constructional design: Sandwich-type rem. seal Flanged remote seal Quick-release remote seal Clamp-on seal Other.: ______________ * Connection: Direct connection Capillary on one side; connection to: + side – side Capillaries on both sides; Capillary length: ___ ft * Vacuum-proof design Yes No * Wetted parts materials: ________________________ * Tube: No Yes, __inch long * Filling liquid ________________________ * Miscellaneous ________________________ Calculation of measuring range necessary? No * Range to be set: * (without calculation) Start-of-scale: _________ psi ( 4 mA) Full-scale: _________ psi (20 mA) * Required measuring accuracy: < . % of set span per Error: _________ : _________ 18 °F change in : _________ temperature Please fill in this questionnaire and enclose with every order! *) Values must be entered here! Checked: 1/244 Name: Department: Date: Siemens FI 01 · 2015 US Edition Yes * Medium ____________________________ * Density of medium: _______ * Temperature of medium: kg/m3 Normal ________ °F Minimum ________ °F Maximum ________ °F * Ambient temperature on capillaries: Normal ________ °F Minimum ________ °F Maximum ________ °F * Ambient temperature on transmitter: Normal ________ °F Minimum ________ °F Maximum ________ °F * Operating pressure referred to absolute zero: ____ psiabs * Does a vacuum occur during startup? No Yes If yes, associated temperature of medium: ________ °F A B C1 C2 D * Installation type, see pages 1/239 and 1/240 E G H J * Measuring: With install. types A, B, C1, C2 and D: from ___ to ___ psi range With install. types A, B, G, H and J: HU = ___ inch; HO = ___ inch * Dimensions: With install. types A, B, C1 and C2: H1 = ___ inch With install. types D, G, H and J: HV = ___ inch * Start-of-scale value following calculation: _________ psi ( 4 mA) * Full-scale value following calculation: _________ psi (20 mA) * Associated span: _________ psi < . % of set span per 18 °F * Error to be expected: _________ _________ change in temperature