© Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 - Technical description ■ Overview ■ Application SITRANS P410 pressure transmitters can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 kHz to 1 GHz makes the P410 suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Flameproof enclosure" may be installed in hazardous areas (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. SITRANS P410 pressure transmitters are digital pressure transmitters with a high level of operating convenience. Technically, they are based on the SITRANS P DS III but offer an increased measuring accuracy of 0.04%. This means the SITRANS P 410 is perfectly suited for measuring tasks with increased accuracy requirements. The parameterization is performed using input buttons or via HART or via PROFIBUS PA or FOUNDATION Fieldbus interface. The comprehensive functionality makes for precise adjustment of the pressure transmitter to the requirements of the plant. Operation is very simple, despite the variety of setting options. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed in hazardous areas (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the respective harmonized European standards (ATEX). The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. SITRANS P410 pressure transmitters are available in various versions for measuring: • Gauge pressure • Differential pressure • Volume flow • Mass flow ■ Benefits • • • • • • • • • • High quality and service life For aggressive and non-aggressive gases, vapors and liquids Extensive diagnostics and simulation functions Minimal conformity error Good long-term stability Wetted parts made of high-grade materials (e.g., stainless steel, Hastelloy) Infinitely adjustable spans from 0.01 bar to 160 bar (0.15 psi to 2321 psi) for P410 with HART interface Nominal measuring ranges from 1 bar to 160 bar (14.5 psi to 2321 psi) for P410 with PROFIBUS PA and FOUNDATION Fieldbus interface High measuring accuracy Parameterization over input buttons and HART, PROFIBUS PA or FOUNDATION Fieldbus interface. 1/198 Siemens FI 01 · 2016 The pressure transmitter can be operated locally over 3 input buttons or programmed externally over HART or over PROFIBUS PA or FOUNDATION Fieldbus interface. Pressure transmitter for gauge pressure Measured variable: Gauge pressure of aggressive and non-aggressive gases, vapors and liquids. Span (infinitely adjustable) for P410 with HART: 0.01 bar to 160 bar (0.15 psi to 2321 psi) Nominal measuring range for P410 with PROFIBUS PA and FOUNDATION Fieldbus: 1 bar to 160 bar (14.5 psi to 2321 psi) Pressure transmitters for differential pressure and flow Measured variables: • Differential pressure • Small positive or negative pressure • Flow q ~ p (together with a primary differential pressure device (see Chapter "Flow Meters")) Span (infinitely adjustable) for P410 with HART: 1 mbar ... 30 bar (0.0145 ... 435 psi) Nominal measuring range for P410 with PROFIBUS PA and FOUNDATION Fieldbus: 20 mbar ... 30 bar (0.29 ... 435 psi) © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Technical description ■ Design 1 2 8 1 2 3 4 5 6 7 8 Plastic cover as access to the input keys Screw cover with viewing pane Digital display Locking screw 7 Process connection Screw cover with viewing pane 6 Rating plate Inlet with cable gland 3 4 5 Front view The transmitter consists of various components depending on the order. The possible versions are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (7, Figure "Front view") with the Article No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover (6) is screwed on at the front and rear of the housing. The front cover can be fitted with a viewing pane so that the measured values can be read directly on the display. The inlet (8) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (5). The measuring cell is prevented from rotating by a locking screw (4). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (1), which hides the input keys. Example for an attached measuring point label Y01 or Y02 = max. 27 char. Y15 = max. 16 char. Y99 = max. 10 char. Y16 = max. 27 char. .... to .... mbar Measuring point number (TAG No.) 1234 Measuring point text Siemens FI 01 · 2016 1/199 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Technical description ■ Function Operation of electronics with HART communication Operation of electronics with PROFIBUS PA communication 9 8 9 8 0.0.0.0.0 00 M 0.0.0.0.0 00 M 10 4 5 2 3 4 IA, UH μC 5 μC 7 PA interface 7 HART interface EEPROM EEPROM Electronics Electronics 6 Sensor 1 Sensor pe Measuring cell 1 2 3 4 5 6 Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 10 Diode circuit and connection for external ammeter IA Output current UH Power supply Pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 20 mA. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans 63 bar measure the input pressure compared to atmosphere, transmitters with spans 160 bar compared to vacuum. 1/200 Siemens FI 01 · 2016 6 pe 1 2 3 4 5 6 7 Power supply unit Coupler 11 12 EEPROM 1 6 6 Power supply 10 PROFIBUS DP 3 PROFIBUS-PA 2 EEPROM 1 BusMaster Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics PROFIBUS-PA interface 8 9 10 11 12 Three input keys (local operation) Digital display Power supply DP/PA coupler or link Bus master pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Technical description Operation of electronics with FOUNDATION Fieldbus communication Mode of operation of the measuring cells Measuring cell for gauge pressure 9 8 0.0.0.0.0 00 2 3 4 5 5 4 7 FF interface μC EEPROM 6 Foundation Fieldbus M 3 Power supply unit Coupler pe EEPROM 6 Sensor Measuring cell for gauge pressure, function diagram pe Measuring cell 1 2 3 4 5 6 7 Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics FF interface Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable 2 Electronics 1 1 2 3 4 5 pe 1 Power supply 10 8 9 10 Three input keys (local operation) Digital display Power supply pe Input variable The pressure pe is applied through the process connection (2, Figure "Measuring cell for gauge pressure, function diagram) to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the differential pressure. Measuring cell for differential pressure and flow 2 3 4 Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. 1 + - 1 5 7 1 2 3 4 5 6 7 Seal diaphragm O-ring Overload diaphragm Silicon pressure sensor Process flange Body of measuring cell Filling liquid 6 Measuring cell for differential pressure and flow, function diagram The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and flow, function diagram") and the filling liquid (7) to the silicon pressure sensor (4). The measuring diaphragm is flexed by the applied differential pressure. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the differential pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (3) is flexed until the seal diaphragm rests on the body of the measuring cell (6), thus protecting the silicon pressure sensor from overloads. Siemens FI 01 · 2016 1/201 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 - Technical description Parameterization SITRANS P410 Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input buttons (local operation) With the input buttons you can easily set the most important parameters without any additional equipment. Parameterization using HART Parameterization using HART is performed with a HART Communicator or a PC. + 230 ... 1100 Ω SITRANS P transmitter Power supply HART communicator Communication between a HART Communicator and a pressure transmitter When parameterizing with the HART Communicator, the connection is made directly to the 2-wire cable. + 230 ... 500 Ω SITRANS P transmitter HART modem Power supply PC or laptop Diagnostic functions for SITRANS P410 with HART • Zero correction display • Event counter • Limit transmitter • Saturation alarm • Slave pointer • Simulation functions • Maintenance timer Available physical units of display for SITRANS P410 with HART Physical variable Physical dimensions Pressure (setting can also be Pa, MPa, kPa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C), made in the factory) mmH2O, ftH2O (20 °C), inHg, mmHg Level (height data) m, cm, mm, ft, in Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz volume flow m3/d, m3/h, m3/s, l/min, l/s, ft3/d, ft3/min, ft3/s, US gallon/min, US gallon/s Mass flow t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d, g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s, LTon/d, LTon/h, STon/d, STon/h, STon/min Temperature K, °C, °F, °R Miscellaneous %, mA Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. Through the PROFIBUS the DS III with PROFIBUS PA is connected to a process control system, e. g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). USB/RS 232 Parameterization through FOUNDATION Fieldbus interface HART communication between a PC communicator and a pressure transmitter When parameterizing with a PC, the connection is made through a HART modem. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameters, SITRANS P410 with HART Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III with FOUNDATION Fieldbus is connected to a process control system. Communication is possible even in a potentially explosive environment. For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Adjustable parameters for SITRANS P410 with PROFIBUS PA and FOUNDATION Fieldbus Parameters Input keys (DS III HART) HART communication Start of scale Full-scale value Electrical damping Start-of-scale value without application of a pressure ("Blind setting") Full-scale value without application of a pressure ("Blind setting") Zero adjustment current transmitter Fault current Disabling of buttons, write protection Type of dimension and actual dimension Characteristic (linear / squarerooted) Input of characteristic Freely-programmable LCD Diagnostic functions x x x x x x x x Parameters Input keys PROFIBUS PA and FOUNDATION Fieldbus interface Electrical damping x x x x Zero adjustment (correction of position) x x x x x x x x x x1) Buttons and/or function disabling x x Source of measured-value display x x Physical dimension of display x x Position of decimal point x x 1) 2) Cancel apart from write protection Only differential pressure 1/202 Siemens FI 01 · 2016 x x Bus address x x x2) x2) Adjustment of characteristic x x x x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Technical description Diagnostic functions for SITRANS P410 with PROFIBUS PA and FOUNDATION Fieldbus • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), made in the factory) inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg Level (height data) m, cm, mm, ft, in, yd Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid volume flow m3/s, m3/min, m3/h, m3/d, l/s, l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min, ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, °C, °F, °R Miscellaneous % Siemens FI 01 · 2016 1/203 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure ■ Technical specifications SITRANS P410 for gauge pressure Input Measured variable Gauge pressure Span (fully adjustable) or measuring range, max. operating HART pressure (in accordance with 2014/68/EU Pressure Equipment Directive) and max. test pressure (pursuant to DIN 16086) PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring Max. operating pres- Max. perm. range sure MAWP (PS) test pressure 0.01 ... 1 bar 1 ... 100 kPa 0.15 ... 14.5 psi 1 bar 100 kPa 14.5 psi 4 bar 400 kPa 58 psi 6 bar 600 kPa 87 psi 0.04 ... 4 bar 4 ... 400 kPa 0.58 ... 58 psi 4 bar 400 kPa 58 psi 7 bar 0.7 MPa 102 psi 10 bar 1 MPa 145 psi 0.16 ... 16 bar 16 ... 1600 kPa 2.3 ... 232 psi 16 bar 1600 kPa 232 psi 21 bar 2.1 MPa 305 psi 32 bar 3.2 MPa 464 psi 0.63 ... 63 bar 63 ... 6300 kPa 9.1 ... 914 psi 63 bar 6300 kPa 914 psi 67 bar 6.7MPa 972 psi 100 bar 10 MPa 1450 psi 1.6 ... 160 bar 0.16 ... 16 MPa 23 ... 2321 psi 160 bar 16 MPa 2321 psi 167 bar 16.7 MPa 2422 psi 250 bar 2.5 MPa 3626 psi Lower measuring limit • Measuring cell with silicone oil filling 30 mbar a/3 kPa a/0.44 psia Upper measuring limit 100 % of max. span Output HART PROFIBUS PA/FOUNDATION Fieldbus Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) Physical bus - Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Load 1/204 Siemens FI 01 · 2016 IEC 61158-2 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure SITRANS P410 for gauge pressure Measuring accuracy Acc. to IEC 60770-1 Reference conditions • Increasing characteristic • Start-of-scale value 0 bar/kPa/psi • Stainless steel seal diaphragm • Silicone oil filling • Room temperature 25 °C (77 °F) Measuring span ratio r (spread, Turn-Down) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - 1 bar/100 kPa/14.5 psi 4 bar/400 kPa/58 psi 16 bar/1.6 MPa/232 psi 63 bar/6.3 MPa/914 psi 160 bar/16 MPa/2321 psi r5: 5 < r 100 : 0.04 % (0.004 r + 0.045) % Influence of ambient temperature (in percent per 28 °C (50 °F)) • 1 bar/100 kPa/14.5 psi (0.05 r + 0.1) % • 4 bar/400 kPa/58 psi 16 bar/1.6 MPa/232 psi 63 bar/6.3 MPa/914 psi 160 bar/16 MPa/2321 psi (0.025 r + 0.125) % Long-term stability (temperature change 30 °C ( 54 °F)) • 1 bar/100 kPa/14.5 psi 4 bar/400 kPa/58 psi (0.25 r) % in 5 years • 16 bar/1.6 MPa/232 psi 63 bar/6.3 MPa/914 psi 160 bar/16 MPa/2321 psi (0.125 r) % in 5 years Effect of mounting position 0.05 mbar/0.005 kPa/0.000725 psi per 10° inclination (zero point correction is possible with position error compensation) Effect of auxiliary power supply (in percent per change in voltage) 0.005 % per 1 V Measuring value resolution for PROFIBUS PA and FOUNDATION Fieldbus 3 10-5 of nominal measuring range Siemens FI 01 · 2016 1/205 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure SITRANS P410 for gauge pressure Rated conditions Degree of protection (to EN 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design Weight (without options) Die-cast aluminum: 2.0 kg ( 4.4 lb) Stainless steel precision casting: 4.6 kg ( 10.1 lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Connection shank Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4602 • Oval flange Stainless steel, mat. no. 1.4404/316L • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection Connection shank G½B to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MAWP 2320 psi)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518 Material of mounting bracket Steel Sheet-steel, Mat. No. 1.0330, chrome-plated Stainless steel Sheet stainless steel, mat. no. 1.4301 (SS 304) Power supply UH HART Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode Power supply Separate 24 V power supply necessary PROFIBUS PA/ FOUNDATION Fieldbus Supplied through bus - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Bus voltage Current consumption 1/206 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure SITRANS P410 for gauge pressure Certificates and approvals Classification according to PED 2014/68/EU For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 4, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X - Marking Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 174 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To circuits with values: UH = 10.5 ... 45 V To circuits with values: UH = 9 ... 32 V DC DC • Dust explosion protection for zone 20 (pending) PTB 01 ATEX 2055 - Marking Ex II 1 D Ex ta IIIC T120°C Da Ex II 1/2 D Ex ta/tb IIIC T120°C Da/Db - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Dust explosion protection for zone 21/22 (pending) PTB 01 ATEX 2055 - Marking Ex II 2 D Ex tb IIIC T120°C Db - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X - Marking Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex nA) Um = 45 V Um = 32 V - Connections (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion protection acc. to FM (pending) - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA (pending) - Identification (XP/DIP) or (IS) Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Siemens FI 01 · 2016 1/207 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function 1/208 Siemens FI 01 · 2016 - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure Selection and Ordering data Article No. Order code Pressure transmitter for gauge pressure, SITRANS P410 with HART 7MF4033- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Measuring span (min. ... max.) 0.01 ... 1 bar (0.15 ... 14.5 psi) 0.04 ... 4 bar (0.58 ... 58 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 0.63 ... 63 bar (9.14 ... 914 psi) 1.6 ... 160 bar (23.2 ... 2320 psi) Wetted parts materials Seal diaphragm } } } } } } 1 B C D E F Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 1) 2) 3) 4) Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting5) } } Electrical connection / cable entry • Screwed gland M20 x1 .5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector11) • M12 connectors (stainless steel)11)12) 0 1 2 3 4 5 6 } Version • Standard version, German plate inscription, setting for pressure unit: bar • International version, English plate inscription, setting for pressure unit: bar } • Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"6) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"7) - "Ex nA/ic (Zone 2)"8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"7)9) (pending) • FM + CSA intrinsic safe (is) (pending)10) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D7)9)10) (pending) • With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)"6)10) (pending) A B C Y 0 3 1 2 3 A } B D P E R F S NC } B C D F Siemens FI 01 · 2016 1/209 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure Article No. Order code 7MF4033- 7 7 7 7 7 - 7 7 7 7 -Z C41 Selection and Ordering data Pressure transmitter for gauge pressure, SITRANS P410 with HART Display • Without display • Without visible display (display concealed, setting: mA) } 0 1 • With visible display (setting: mA) 6 • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 7 } Available ex stock Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: • Brief instructions (Leporello) • DVD with detailed documentation 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-.... and 7MF4900-1...-.B 4) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 5) Not in conjunction with Electrical connection "Han7D plug". 6) Without cable gland, with blanking plug 7) With enclosed cable gland Ex ia and blanking plug 8) Configurations with HAN and M12 connectors are only available in Ex ic. 9) Only in connection with IP66. 10) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 11) Only in connection with Ex approval A, B or E. 12) M12 delivered without cable socket 2) 1/210 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure Selection and Ordering data Article No. Order code Pressure transmitter for gauge pressure SITRANS P410 with PROFIBUS PA (PA) 7MF4034- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4035- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Nominal measuring range 1 bar (14.5 psi) 4 bar (58 psi) 16 bar (232 psi) 63 bar (914 psi) 160 bar (2320 psi) 1 B C D E F Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 1) 2) 3) 4) Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) 5) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard version, German label inscription, setting of pressure unit: bar • International version, English label inscription, setting of pressure unit: psi • Chinese version, English label inscription, setting of pressure unit: kPa All versions incl. DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Incl. Compact operating instructions in various EU languages. A B C Y 0 1 2 3 4 5 6 0 3 1 2 3 Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"6) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"7) - "Ex nA/ic (Zone 2)"8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"7) 9) (not for P410 with FOUNDATION Fieldbus) (pending) • FM + CSA intrinsic safe (is) (pending)10) A B D P E R F • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D7)9)10) (pending) S • With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)"6)10) (pending) NC Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)11) 12) B C F Siemens FI 01 · 2016 1/211 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure Selection and Ordering data Article No. Order code Pressure transmitter for gauge pressure SITRANS P410 with PROFIBUS PA (PA) 7MF4034- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4035- 7 7 7 7 7 - 7 7 7 7 -Z C41 77777 - 7777 Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • with customer-specific display (setting as specified, Order code "Y21" required) 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • DVD with detailed documentation 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-.... and 7MF4900-1...-.B 4) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 5) M10 fastening thread: Max. span 160 bar (2320 psi) 7/16-20 UNF and M12 fastening thread: Max. span 400 bar (5802 psi) 6) Without cable gland, with blanking plug. 7) With enclosed cable gland Ex ia and blanking plug. 8) Configurations with HAN and M12 connectors are only available in Ex ic. 9) Only in connection with IP66. 10) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 11) M12 delivered without cable socket. 12) Only in connection with Ex approval A, B, E or F. 2) 1/212 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: • Steel • Stainless steel 304 • Stainless steel 316L Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Cable sockets for M12 connectors (metal (CuZn)) Rating plate inscription (instead of German) • English • French • Spanish • Italian HART PA A01 A02 A03 A30 A31 A32 A33 A50 FF Explosion protection "Explosion-proof" to NEPSI (China) (only for transmitter 7MF4...-.....-.D..) E563) Ex protection "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) E573) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) E583) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (pending) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E703) Ex-protection Ex ia according to EAC Ex (Russia) E804) E814) Ex-protection Ex d according to EAC Ex (Russia) E824) Ex-protection Ex nA/ic (Zone 2) according to EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone 1D/2D according to EAC Ex (Russia) E834) Two coats of lacquer on casing and cover (PU on epoxy) G10 Transient protector 6 kV (lightning protection) J01 Oval flange NAM (ASTAVA) J06 Quality Inspection Certificate (5-point characteristic curve test) according to IEC 60770-21) C11 B21 E01 English rating plate Pressure units in inH20 and/or psi Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“ and IP66) E553) FF E24 C12 HART PA Dual seal Inspection certificate Acc. to EN 10204-3.1 Further designs Add "-Z" to Article No. and specify Order code. Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) B11 B12 B13 B14 2) Order code Selection and Ordering data Factory certificate Acc. to EN 10204-2.2 C14 Functional safety (SIL2) (pending) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 Increased measuring accuracy (mandatory specification for SITRANS P410) C41 Device passport Russia C99 Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) D07 Degree of protection IP66/IP68 (only for M20x1.5 and ½-14 NPT) D12 Supplied with oval flange (1 item), PTFE packing and screws in thread of oval flange D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 TAG plate empty (no inscription) D61 Factor valve block mounting for SITRANS P410 is possible. Depending on the available P410 variants, please see the configuration options for SITRANS P DS III (page 1/193). 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Option does not include ATEX approval, but instead includes only the country-specific approval. 4) Approval pending. Siemens FI 01 · 2016 1/213 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for gauge pressure Selection and Ordering data Order code Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. HART PA FF Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Y17 Setting of pressure indication in pres Y21 sure units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indication in Y22 + non-pressure units2) Y01 Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Max. 8 characters, specify in plain text: Y17: ........................................... = available Ordering example Item line: 7MF4033-1EA00-1AA7-Z C41 B line: A01 + Y01 + Y21 C line: Y01: 10 ... 20 bar (145 ... 290 psi) C line: Y21: bar (psi) 1) 2) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Preset values can only be changed over SIMATIC PDM. 1/214 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for gauge pressure 53 (2.1) 54 (2.13) 27 (1.1) approx. 96 (3.78) Ø80 (3.15) 2 17 (0.67) 29 (1.14) 5 84 (3.31) 6 3 4 3 7 72 (2.8) 8 120 (4.72) 68 (2.68) 9 176 (6.93) 237 (9.33) 143 (5.6) 74 (2.9) 50 (1.97) 117 (4.61) 15 (0.6) 1 24 (0.94) ■ Dimensional drawings Space for rotation of housing min. 90 (3.54) 4) 123 (4.84) 1 Ø50 ... 60 (1.97 ... 2.36) Electronic side, digital display (longer overall length for cover with window)1) 2 Terminal side1) 3 Electrical connection: Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/Han 8D2) 3) plug 4 Harting adapter 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" Minimum distance for rotating 2) 3) 4) 105 (4.13) 5 Protective cover over keys 6 Blanking plug 7 8 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) Process connection: Connection shank G½B 9 Mounting bracket (option) SITRANS P410 pressure transmitters for gauge pressure, dimensions in mm (inch) Siemens FI 01 · 2016 1/215 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow ■ Technical specifications SITRANS P410 for differential pressure and flow Input Measured variable Differential pressure and flow Span (fully adjustable) or measuring range, max. operating HART pressure (in accordance with 2014/68/EU Pressure Equipment Directive) PROFIBUS PA/ FOUNDATION Fieldbus Span Nominal measuring Max. operating pressure MAWP (PS) range 2.5 ... 250 mbar 0.2 ... 25 kPa 1 ... 100 inH2O 250 mbar 25 kPa 100 inH2O 6 ... 600 mbar 0.6 ... 60 kPa 2.4 ... 240 inH2O 600 mbar 60 kPa 240 inH2O 16 ... 1600 mbar 1.6 ...160 kPa 6.4 ... 642 inH2O 1600 mbar 160 kPa 642 inH2O 50 ... 5000 mbar 5 ... 500 kPa 20 ... 2000 inH2O 5000 mbar 500 kPa 2000 inH2O 0.3 ... 30 bar 0.03 ... 3 MPa 4.35 ... 435 psi 30 bar 3 MPa 435 psi 6 ... 600 mbar 0.6 ... 60 kPa 2.4 ... 240 inH2O 600 mbar 60 kPa 240 inH2O 16 ... 1600 mbar 1.6 ...160 kPa 6.4 ... 642 inH2O 1600 mbar 160 kPa 642 inH2O 50 ... 5000 mbar 5 ... 500 kPa 20 ... 2000 inH2O 5000 mbar 500 kPa 2000 inH2O 0.3 ... 30 bar 0.03 ... 3 MPa 4.35 ... 435 psi 30 bar 3 MPa 435 psi 160 bar 16 MPa 2320 psi 420 bar 42 MPa 6091 psi Lower measuring limit • Measuring cell with silicone oil filling -100 % of max. span (-33 % with measuring cell 30 bar/3 MPa/435 psi) or 30 mbar a/3 kPa a/0.44 psi a Upper measuring limit 100 % of max. span Start of scale value Between the measuring limits (fully adjustable) Output HART PROFIBUS PA/ FOUNDATION Fieldbus Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) Physical bus - Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Load 1/216 Siemens FI 01 · 2016 IEC 61158-2 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow SITRANS P410 for differential pressure and flow Measuring accuracy Acc. to IEC 60770-1 Reference conditions • Increasing characteristic • Start-of-scale value 0 bar/kPa/psi • Stainless steel seal diaphragm • Silicone oil filling • Room temperature 25 °C (77 °F) Measuring span ratio r (spread, Turn-Down) r = max. measuring span/set measuring span or nom. pressure range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi r5: 5 < r 100 : 0.04 % (0.004 r + 0.045) % r5: 5 < r 100 : 0.04 % (0.004 r + 0.045) % r5: 5 < r 100 : 0.08 % (0.008 r + 0.09) % • Square-rooted characteristic (flow > 50 %) - 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi • Square-rooted characteristic (flow > 25 ... 50 %) - 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi Influence of ambient temperature (in percent per 28 °C (50 °F)) • 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi (0.025 r + 0.125) % Influence of static pressure • on the zero point (PKN) - 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi (0.1 r) % per 70 bar (zero-point correction is possible with position error adjustment) - 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi (0.2 r) % per 70 bar (zero-point correction is possible with position error adjustment) • on the span (PKS) - 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi 30 bar/3 MPa/435 psi 0.14 % per 70 bar Long-term stability (temperature change ± 30 °C (± 54 °F)) Static pressure max. 70 bar/7 MPa/1015 psi • 250 mbar/25 kPa/3.63 psi 600 mbar/60 kPa/8.7 psi 1600 mbar/160 kPa/23.21 psi 5 bar/500 kpa/72.5 psi (0.125 r) % in 5 years • 30 bar/3 MPa/435 psi (0.25 r) % in 5 years Effect of mounting position (in pressure per change in angle) 0.7 mbar/0.07 kPa/0.028 inH2O per 10° inclination (zero-point correction is possible with position error adjustment) Effect of auxiliary power supply (in percent per change in voltage) 0.005 % per 1 V Measuring value resolution for PROFIBUS PA and FOUNDATION Fieldbus 3 10-5 of nominal measuring range Siemens FI 01 · 2016 1/217 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow SITRANS P410 for differential pressure and flow Rated conditions Degree of protection (to EN 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) -20 ... +100 °C (-4 ... +212 °F) with 30 bar measuring cell • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design Weight (without options) Die-cast aluminum: 4.5 kg ( 9.9 lb) Stainless steel precision casting: 7.1 kg ( 15.6 lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 • Process flanges and sealing screw Stainless steel, mat. no. 1.4408, Hastelloy C4, mat. no. 2.4602 • O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to IEC 61518 Material of mounting bracket • Steel Sheet-steel, Mat. No. 1.0330, chrome-plated • Stainless steel Sheet stainless steel, mat. no. 1.4301 (SS 304) Power supply UH HART Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode Power supply Separate 24 V power supply necessary PROFIBUS PA/ FOUNDATION Fieldbus Supplied through bus - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Bus voltage Current consumption 1/218 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow SITRANS P410 for differential pressure and flow Certificates and approvals HART Classification according to PED 2014/68/EU For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 4, paragraph 3 (sound engineering practice) PROFIBUS PA/ FOUNDATION Fieldbus Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X - Marking Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To circuits with values: UH = 10.5 ... 45 V To circuits with values: UH = 9 ... 32 V DC DC • Dust explosion protection for zone 20 (pending) PTB 01 ATEX 2055 - Marking Ex II 1 D Ex ta IIIC T120°C Da Ex II 1/2 D Ex ta/tb IIIC T120°C Da/Db - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Dust explosion protection for zone 21/22 (pending) PTB 01 ATEX 2055 - Marking Ex II 2 D Ex tb IIIC T120°C Db - Connection To circuits with values: UH = 10.5 ... 45 V To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W DC; Pmax = 1 W • Type of protection "n" (zone 2) PTB 13 ATEX 2007 X - Marking Ex II 2/3 G Ex nA IIC T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex nA) Um = 45 V Um = 32 V - Connection (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion protection acc. to FM (pending) - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA (pending) - Identification (XP/DIP) or (IS) Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Siemens FI 01 · 2016 1/219 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for PC SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customerspecific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function 1/220 Siemens FI 01 · 2016 - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Selection and Ordering data Article No. Order Code SITRANS P410 with HART pressure transmitters for differential pressure and flow, PN 160 (MAWP 2320 psi) 7MF4433- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Measuring span (min. ... max.) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) } } } } } } 1 D E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version for diaphragm seal1) 2) 3) 4) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Vent on side of process flange5) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) } } A B C Y 2 0 6 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting6) Version • Standard version, German plate inscription, setting for pressure unit: bar • International version, English plate inscription, setting for pressure unit: bar • Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"7) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"8) - "Ex nA/ic (Zone 2)"9) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"8)10) (pending) • FM + CSA intrinsic safe (is) (pending)11) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D8)10)11) (pending) • With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)"7)11) (pending) } } } 2 3 1 2 3 A } B D P E R F S NC Siemens FI 01 · 2016 1/221 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Article No. Order Code 7MF4433- 7 7 7 7 7 - 7 7 7 7 -Z C41 Selection and Ordering data SITRANS P410 with HART pressure transmitters for differential pressure and flow, PN 160 (MAWP 2320 psi) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector12)13) • M12 connectors (stainless steel)14)15) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) } B C D F } 0 1 6 7 } Available ex stock Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: • Brief instructions (Leporello) • DVD with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF443.-..Y..-.... and 7MF4900-1...-.B 4) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 5) Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). 6) Not in conjunction with Electrical connection "Han7D plug". 7) Without cable gland, with blanking plug 8) With enclosed cable gland Ex ia and blanking plug 9) Configurations with HAN and M12 connectors are only available in Ex ic. 10) Only in connection with IP66. 11) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. Only in connection with Ex approval A, B or E. 13) Permissible only for crimp-contact of conductor cross-section 1 mm2 12) 14) Only in connection with Ex approval A, B, E or F. 15) M12 delivered without cable socket. 1/222 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Article No. Selection and Ordering data Order code Pressure transmitters for differential pressure and flow PN 160 (MAWP 2320 psi) SITRANS P410 with PROFIBUS PA (PA) 7MF4434- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4435- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal 1 Nominal measuring range 250 mbar (100.4 inH2O) 600 mbar (240.9 inH2O) 1600 mbar (642.4 inH2O) 5 bar (2008 inH2O) 30 bar (435 psi) D E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell A B C Y Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 1) 2) 3) 4) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges 5) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) 2 0 6 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel 2 3 Die-cast aluminum Stainless steel precision casting Version • Standard version, German plate inscription, setting for pressure unit: bar • International version, English plate inscription, setting for pressure unit: bar • Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"6) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"7) - "Ex nA/ic (Zone 2)" 8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"7) 9)(not for DS III FF) (pending) • FM + CSA intrinsic safe (is) (pending)10) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D7)9)10) (pending) • With FM + CSA, Type of protection: - "Intrinsic Safe and Explosion Proof (is + xp)"8)10) (pending) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)11) 12) } } 1 2 3 A B D P E R F S NC B C F Siemens FI 01 · 2016 1/223 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Selection and Ordering data Article No. Order code Pressure transmitters for differential pressure and flow PN 160 (MAWP 2320 psi) SITRANS P410 with PROFIBUS PA (PA) 7MF4434- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4435- 7 7 7 7 7 - 7 7 7 7 -Z C41 Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • DVD with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) 2) 3) 4) 5) 6) 7) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF443.-..Y..-.... and 7MF4900-1...-.B The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). Without cable gland, with blanking plug. With enclosed cable gland Ex ia and blanking plug. 8) Configurations with HAN and M12 connectors are only available in Ex ic. Only in connection with IP66. Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 11) Only in connection with Ex approval A, B, E or F. 12) M12 delivered without cable socket 9) 10) 1/224 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x U-washer or 1 x bracket, 2 x nut, 2 x U-washer) made of: • Steel • Stainless steel 304 • Stainless steel 316L O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Order code Selection and Ordering data HART PA FF A01 A02 A03 A20 A21 A22 A23 Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) (only together with seal diaphragm made of Hastelloy and stainless steel) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Supplied with oval flange set (2 items), PTFE packings and screws in thread of process flanges D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 TAG plate empty (no inscription) D61 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“and IP66) E01 A30 A31 A32 A33 Dual seal E24 Sealing screws (2 units) ¼-18 NPT, with valve in mat. of process flanges A40 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E553) Cable sockets for M12 connectors (metal (CuZn)) A50 Explosion protection "Explosion-proof" to NEPSI (China) (only for transmitter 7MF4...-.....-.D..) E563) Explosion-proof "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) E573) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) E583) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (pending) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E703) Ex-protection Ex ia according to EAC Ex (Russia) E804) Ex-protection Ex d according to EAC Ex (Russia) E814) Ex-protection Ex nA/ic (Zone 2) according to EAC Ex (Russia) E824) Ex-protection Ex ia + Ex d + Zone 1D/2D according to EAC Ex (Russia) E834) Two coats of lacquer on casing and cover (PU on epoxy) G10 Interchanging of process connection side H01 Vent on side for gas measurements H02 Stainless steel process flanges for vertical differential pressure lines (not together with K01, K02 and K04)5) H03 Rating plate inscription (instead of German) • English • French • Spanish • Italian B11 B12 B13 B14 English rating plate Pressure units in inH2O and/or psi B21 Quality Inspection Certificate (5-point characteristic curve test) according to IEC 60770-21) C11 Inspection certificate2) to EN 10204-3.1 C12 Factory certificate to EN 10204-2.2 C14 Functional safety (SIL2) (pending) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 Increased measuring accuracy (mandatory specification for SITRANS P410) C41 Device passport Russia C99 Siemens FI 01 · 2016 1/225 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Order code Selection and Ordering data HART PA FF Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text: • in the case of linear characteristic curve Y01 (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi • in the case of square rooted characteristic Y02 (max. 5 characters): Y02: ... up to ... mbar, bar, kPa, MPa, psi Transient protector 6 kV (lightning protection) J01 Chambered graphite gasket for process flange J02 Chambered PTFE graphite gasket J03 EPDM O-rings for process flange with approval (WRC/WRAS) J05 Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)6) J08 Vent valve or blanking plug of process flange welded-in (orientation: on left when viewing the display)6) J09 Factor valve block mounting for SITRANS P410 is possible. Depending on the available P410 variants, please see the configuration options for SITRANS P DS III (page 1/193). = available 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Option does not include ATEX approval, but instead includes only the country-specific approval. 4) Approval pending. 5) Not suitable for connection of remote seal. 6) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. HART PA FF 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 char., specify in plain text: Y16: ....... Y16 Y17 Entry of HART address (TAG) Max. 8 char., specify in plain text: Y17: ....... Y21 Setting of pressure indicator in pressure units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indicator in nonpressure units2) Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Y223) + Y01 or Y02 Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available 1) 2) 3) 1/226 Siemens FI 01 · 2016 Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Preset values can only be changed over SIMATIC PDM. Not in conjunction with over-filling safety device for flammable and nonflammable liquids (Order code "E08") © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Selection and Ordering data Article No. Order code SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) 7MF4533- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Measuring span (min. ... max.) 6 ... 600 mbar (2.4 ... 240 inH2O) 16 ... 1600 mbar (6.4 ... 642 inH2O) 50 ... 5000 mbar (20 ... 2000 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 1 E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Version for diaphragm seal 1) 2) 3) 4) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) A B Y 3 1 7 5 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting5) Version • Standard version, German plate inscription, setting for pressure unit: bar • International version, English plate inscription, setting for pressure unit: bar • Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"6) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"7) - "Ex nA/ic (Zone 2)"8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"7)9) (pending) • FM + CSA intrinsic safe (is) (pending)10) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D7)9)10) (pending) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)" 6)10), max PN 360 (pending) Electrical connection/cable entry • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector11) 12) • M12 connectors (stainless steel)13)14) 2 3 1 2 3 A B D P E R F S NC B C D F Siemens FI 01 · 2016 1/227 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Selection and Ordering data SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) Article No. Order code 7MF4533- 7 7 7 7 7 - 7 7 7 7 -Z C41 0 1 6 7 Power supply units see Chap. 7 "Supplementary Components". Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) The diaphragm seal is to be specified with a separate order number and must be included wiht the transmitter order number, for example 7MF453.-..Y..-.... and 7MF4900-1....-.B 4) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 5) Not in conjunction with Electrical connection "Han7D plug". 6) Without cable gland, with blanking plug 7) With enclosed cable gland Ex ia and blanking plug 8) Configurations with HAN and M12 connectors are only available in Ex ic. 9) Only in connection with IP66. 10) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 11) Only in connection with Ex approval A, B or E. 12) Permissible only for crimp-contact of conductor cross-section 1 mm2 13) Only in connection with Ex approval A, B, E or F. 14) M12 delivered without cable socket. 1/228 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Selection and Ordering data Article No. Order Code Pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) SITRANS P410 with PROFIBUS PA (PA) 7MF4534- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4535- 7 7 7 7 7 - 7 7 7 7 -Z C41 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Nominal measuring range 600 mbar (240 inH2O) 1600 mbar (642 inH2O) 5 bar (2000 inH2O) 30 bar (435 psi) 1 E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Version for diaphragm seal 1) 2) 3) 4) Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing). - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) A B Y 3 1 7 5 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting Version • Standard version, German plate inscription, setting for pressure unit: bar • International version, English plate inscription, setting for pressure unit: bar • Chinese version, English plate inscription, setting for pressure unit: Pascal All versions include DVD with documentation for SITRANS P in German, English, French, Italian and Spanish. Includes Compact operating instructions in various EU languages. Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"5) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"6) - "Ex nA/ic (Zone 2)" 7) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"6)8) (not for P410 with FOUNDATION Fieldbus) (pending) • FM + CSA intrinsic safe (is) (pending)9) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX) + Zone 1D/2D6)7)9) (pending) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"6)9), max PN 360 (pending) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel) 10) 11) 2 3 1 2 3 A B D P E R F S NC B C F Siemens FI 01 · 2016 1/229 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Selection and Ordering data Article No. Order Code Pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) SITRANS P410 with PROFIBUS PA (PA) 7MF4534- 7 7 7 7 7 - 7 7 7 7 -Z C41 SITRANS P410 with FOUNDATION Fieldbus (FF) 7MF4535- 7 7 7 7 7 - 7 7 7 7 -Z C41 1 7777 - 7777 Display • Without (display hidden) • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • DVD with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF453.-..Y..-.... and 7MF4900-1....-.B 4) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 5) Without cable gland, with blanking plug. 6) With enclosed cable gland Ex ia and blanking plug. 7) Configurations with HAN and M12 connectors are only available in Ex ic. 8) Only in connection with IP66. 9) Explosion protection acc. to FM/CSA: suitable for installations according to NEC 500/505. 10) Only in connection with Ex approval A, B, E or F. 11) M12 delivered without cable socket 2) 1/230 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel 304 • Stainless steel 316L HART PA FF A01 A02 A03 A20 A21 A22 A23 A30 A31 A32 A33 Sealing screws (2 units) A40 ¼-18 NPT, with valve in mat. of process flanges Cable sockets for M12 connection (metal (CuZn)) A50 B11 B12 B13 B14 B21 Quality Inspection Certificate (5-point char- C11 acteristic curve test) according to IEC 60770-2 Inspection certificate Acc. to EN 10204-3.1 C12 Factory certificate Acc. to EN 10204-2.2 C14 Functional safety (SIL2) (pending) C20 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Functional safety (SIL2/3) C23 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Increased measuring accuracy C41 (mandatory specification for SITRANS P410) Device passport Russia C99 Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) (only together with seal diaphragm made of Hastelloy and stainless steel) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 TAG plate empty (no inscription) D61 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Rating plate inscription (instead of German) • English • French • Spanish • Italian English rating plate Pressure units in inH2O and/or psi Order code Selection and Ordering data Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“and IP66) E01 Dual seal E24 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E551) Ex prot. "Explosion-proof" to NEPSI (China) E561) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Zone 2" to NEPSI (China) E571) (only for transmitter 7MF4...-.....-.E..) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ E581) to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (pending) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E701) Ex-protection Ex ia according to EAC Ex (Russia) E802) Ex-protection Ex d according to EAC Ex (Russia) E812) Ex-protection Ex nA/ic (Zone 2) according to E822) EAC Ex (Russia) Ex-protection Ex ia + Ex d + Zone 1D/2D according to EAC Ex (Russia) E832) Two coats of lacquer on casing and cover (PU on epoxy) G10 Interchanging of process connection side H01 Vent on side for gas measurements H02 Stainless steel process flanges for vertical H03 differential pressure lines Transient protector 6 kV (lightning protec- J01 tion) Chambered graphite gasket for process flange J02 Chambered PTFE graphite gasket J03 EPDM O-rings for process flange with approval (WRC/WRAS) J05 Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)3) J08 Vent valve or blanking plug of process J09 flange welded-in (orientation: on left when viewing the display)3) Factor valve block mounting for SITRANS P410 is possible. Depending on the available P410 variants, please see the configuration options for SITRANS P DS III (page 1/193). 1) Option does not include ATEX approval, but instead includes only the country-specific approval. 2) Approval pending. 3) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. Siemens FI 01 · 2016 1/231 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 for differential pressure and flow Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text: • in the case of linear characteristic curve (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi • in the case of square rooted characteristic (max. 5 characters): Y02: ... up to ... mbar, bar, kPa, MPa, psi 1) Y01 Y02 Y15 Measuring point text (entry in device vari- Y16 able) Max. 27 char., specify in plain text: Y16: ....... Entry of HART address (TAG) Y17 Max. 8 char., specify in plain text: Y17: ......... Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indication in Y22 + non-pressure units2) Y01 or Y02 Specify in plain text: 3 Y22: ..... up to ..... l/min, m /h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset. = available 1) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. 2) Preset values can only be changed over SIMATIC PDM. 1/232 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 for differential pressure and flow ■ Dimensional drawings 143 (5.6) Ø80 (3.15) 1 5 2 29 (1.14) 84 (3.31) 6 3 7 8 166 (6.54) 53 (2.1) 24 (0.94) 69 (2.7) 50 (1.97) 128 (5.04) 15 (0.6) 12 10 11 52 (2.05) 3 17 (0.67) 4 72 (2.83) 68 (2.7) 105 (4.1) Electronic side, digital display (longer overall length for cover with window)1) 2 Terminal side1) 3 Electrical connection: Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/ Han 8D2) 3) plug 4 Harting adapter 5 Protective cover over keys 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" 92 mm (3.62 inch) for minimum distance to permit rotation with indicator 2) 3) 4) 96 (3.8) 134 (5.28) Space for rotation of housing 9 approx. 96 (3.78) 1 262 (10.3) min. 90 (3.54) 4) 120 (4.7) 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Lateral venting for liquid measurement (Standard) 9 Lateral venting for gas measurement (suffix H02) 10 Mounting bracket (option) 11 Sealing screw with valve (option) 12 Process connection: ¼-18 NPT (IEC 61518) SITRANS P410 pressure transmitters for differential pressure and flow, dimensions in mm (inch) Siemens FI 01 · 2016 1/233 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 143 (5.6) 53 (2.1) 17 (0.67) 5 29 (1.14) 84 (3.31) 50 (1.97) 1 approx. 96 (3.78) 6 3 4 3 7 2 min. 90 (3.54) 4) approx. 85 (3.35) 6) Space for rotation of housing 8 60 (2.36) 5) 8 128 (5.04) approx. 217 (8.54) 7) 15 (0.6) 24 (0.94) SITRANS P410 for differential pressure and flow Ø80 (3.15) 1 9 approx. 87 (3.43) 65 (2.56) Electronic side, digital display (longer overall length for cover with window)1) 5 Protective cover over keys 6 Blanking plug 2 Terminal side1) 7 3 Electrical connection: Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/ Han 8D2) 3) plug Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Sealing screw with valve (option) 9 Process connection: ¼-18 NPT (IEC 61518) 1 4 Harting adapter 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" 92 mm (3.6 inch) for minimum distance to permit rotation with indicator 74 mm (2.9 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) 91 mm (3.6 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) 219 mm (8.62 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) 2) 3) 4) 5) 6) 7) SITRANS P410 pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines, optional "H03" , dimensional drawing, dimensions in mm (inch) SITRANS P410 pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines 1/234 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Accessories/Spare parts Selection and Ordering data Article No. Article No. Selection and Ordering data Accessories/Spare parts Mounting screws Mounting bracket and fastening parts for pressure transmitters SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus (7MF403.-.....-..C.) • made of steel • made of stainless steel 304/1.4301 • made of stainless steel 316L/1.4404 For measuring point label, grounding and connection terminals or for display (50 units) 7MF4997-1AB 7MF4997-1AH 7MF4997-1AP Mounting bracket and fastening parts for pressure transmitters SITRANS P410 with HART, P410 with PROFIBUS PA and P10with FOUNDATION Fieldbus (7MF403-.....-..A., -..B., ..D. and ..F.) • made of steel 7MF4997-1AC • made of stainless steel 304/1.4301 } 7MF4997-1AJ • made of stainless steel 316L/1.4404 7MF4997-1AQ Mounting and fastening brackets For differential pressure transmitters with flange thread M10 SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus (7MF443.-...) • made of steel • made of stainless steel 304/1.4301 • made of stainless steel 316L/1.4404 7MF4997-1AD } 7MF4997-1AK 7MF4997-1AR Mounting and fastening brackets For differential pressure transmitters with flange thread M12 SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus (7MF453.-...) • made of steel • made of stainless steel 304/1.4301 • made of stainless steel 316L/1.4404 7MF4997-1AE 7MF4997-1AL 7MF4997-1AS Mounting and fastening brackets For differential pressure transmitters with flange thread 7/16 -20 UNF SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus (7MF443.-... and 7MF453.-...) • made of steel • made of stainless steel 304/1.4301 • made of stainless steel 316L/1.4404 7MF4997-1AF 7MF4997-1AM 7MF4997-1AT Sealing screws (1 set = 2 units) for process flange • made of stainless steel • made of Hastelloy 7MF4997-1CD 7MF4997-1CG 7MF4997-1CH Sealing screws with vent valve Complete (1 set = 2 units) • made of stainless steel • made of Hastelloy } 7MF4997-1CP 7MF4997-1CQ Connection board • for SITRANS P410 • for SITRANS P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus 7MF4997-1DN 7MF4997-1DP O-rings for process flanges made of: • FPM (Viton) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) 7MF4997-2DA 7MF4997-2DB 7MF4997-2DC 7MF4997-2DD 7MF4997-2DE Sealing ring for process connection see "Fittings" } Available ex stock Cover Made of die-cast aluminum, including gasket, for SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus. Compatible for Ex and non-Ex transmitters • without window 7MF4997-1BB • with window } 7MF4997-1BE Cover Made of stainless steel, including gasket, or SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus. Compatible for Ex and non-Ex transmitters • without window • with window Digital indicator Including mounting material, for SITRANS P410 with HART, P410 with PROFIBUS PA and P410 with FOUNDATION Fieldbus Measuring point label • without inscription (5 units) • Printed (1 unit) Data according to Y01 or Y02, Y15, Y16 and Y99 (see "Pressure transmitters") 7MF4997-1BC 7MF4997-1BF 7MF4997-1BR 7MF4997-1CA 7MF4997-1CB-Z Y..: ...................... Siemens FI 01 · 2016 1/235 1 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) 1 SITRANS P410 - Accessories/Spare parts Selection and Ordering data Article No. Documentation The entire documentation is available for download free-of-charge in various languages at: http://www.siemens.com/processinstrumentation/documentation Compact operating instructions SITRANS P DS III/P410 • English, German, Spanish, French, Italian, Dutch • Estonian, Latvian, Lithuanian, Polish, Romanian, Croatian • Bulgarian, Czech, Finnish, Slovakian, Slovenian • Danish, Greek, Portuguese, Swedish, Hungarian The compact operating instructions are available on the DVD supplied with each transmitter. DVD with documentation The DVD contains detailed documentation for all device versions Certificates (order only via SAP) instead of Internet download • hard copy (to order) • on DVD (to order) HART modem with USB interface A5E03434626 A5E03434631 A5E03434645 A5E03434656 A5E00090345 A5E03252406 A5E03252407 } 7MF4997-1DB } Available ex stock Power supply units see Chap. 7 "Supplementary Components". 1/236 Siemens FI 01 · 2016 © Siemens AG 2016 Pressure Measurement Transmitters for applications with advanced requirements (Advanced) SITRANS P410 - Accessories/Spare parts ■ Dimensional drawings 60 30 25 12,5 25 30 Ø9 6 60 R30 12,5 3 134 21 105 120 52,5 72 16,5 R30 3 115 Ø11 72 Mounting bracket for SITRANS P410 gauge pressure-transmitters, dimensions in mm mounting bracket material: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) 38 27 54 20,65 R30 41,3 27 20,65 R6,5 Ø20 3 41,3 54 134 21 105 120 52,5 72 16,5 R30 3 115 Ø11 72 Mounting bracket for SITRANS P410 differential pressure transmitter, dimensions in mm mounting bracket material: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) Siemens FI 01 · 2016 1/237 1