© Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III - Technical description ■ Overview SITRANS P DS III pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The parameterization is performed using control keys or via HART, PROFIBUS-PA or FOUNDATION Fieldbus interface. Extensive functionality enables the pressure transmitter to be precisely adapted to the plant’s requirements. Operation is very simple in spite of the numerous setting options. Transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. Various versions of the DS III pressure transmitters are available for measuring: • Gauge pressure • Absolute pressure • Differential pressure • Level • Volume level • Mass level • Volume flow • Mass flow ■ Benefits • High quality and service life • High reliability even under extreme chemical and mechanical loads • For aggressive and non-aggressive gases, vapors and liquids • Extensive diagnosis and simulation functions • Separate replacement of measuring cell and electronics without recalibration • Minimum conformity error • Good long-term stability • Wetted parts made of high-grade materials (e.g. stainless steel, Hastelloy, gold, Monel, tantalum) 1/90 Siemens FI 01 · 2015 US Edition • Infinitely adjustable span from 0.01 bar to 700 bar (0.15 psi to 10153 psi) for DS III with HART interface • Nominal measuring range from 1 bar to 700 bar (14.5 psi to 10153 psi) for DS III with PROFIBUS PA and FOUNDATION Fieldbus interface • High measuring accuracy • Parameterization over control keys and HART or PROFIBUS PA, or FOUNDATION Fieldbus interface. ■ Application The pressure transmitters of the DS III series, can be used in industrial areas with extreme chemical and mechanical loads. Electromagnetic compatibility in the range 10 kHz to 1 GHz makes the DS III pressure transmitters suitable for locations with high electromagnetic emissions. Pressure transmitters with type of protection "Intrinsic safety" and "Explosion-proof" may be installed within potentially explosive atmospheres (zone 1) or in zone 0. The pressure transmitters are provided with an EC type examination certificate and comply with the corresponding harmonized European standards (ATEX). Pressure transmitters with the type of protection "Intrinsic safety" for use in zone 0 may be operated with power supply units of category "ia" and "ib". The transmitters can be equipped with various designs of remote seals for special applications such as the measurement of highly viscous substances. The pressure transmitter can be programmed locally using the 3 control buttons or externally via HART or PROFIBUS PA or FOUNDATION Fieldbus interface. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Technical description Pressure transmitter for gauge pressure ■ Design Measured variable: Gauge pressure of aggressive and non-aggressive gases, vapors and liquids. Span (infinitely adjustable) for DS III with HART: 0.01 bar to 700 bar (0.15 psi to 10153 psi) 1 Nominal measuring range for DS III with PROFIBUS PA and FOUNDATION Fieldbus: 1 bar to 700 bar (14.5 psi to 10153 psi) 2 Pressure transmitters for absolute pressure Measured variable: Absolute pressure of aggressive and nonaggressive gases, vapors and liquids. Span (infinitely adjustable) for DS III with HART: 8.3 mbar a ... 100 bar a (0.12 ... 1450 psia) Nominal measuring range for DS III with PROFIBUS PA and FOUNDATION Fieldbus: 250 mbar a ... 100 bar a (3.6 ... 1450 psia) There are two series: • Gauge pressure series • Differential pressure series 8 1 2 3 4 5 6 7 8 Plastic cover as access to the input keys Screw cover with viewing pane Digital display Locking screw 7 Process connection Screw cover with viewing pane 6 Rating plate Inlet with cable gland Pressure transmitters for differential pressure and flow Measured variables: • Differential pressure • Small positive or negative pressure • Flow q ~ p (together with a primary differential pressure device (see Chapter "Flow Meters")) Span (infinitely adjustable) for DS III with HART: 1 mbar ... 30 bar (0.0145 ... 435 psi) Nominal measuring range for DS III with PROFIBUS PA and FOUNDATION Fieldbus: 20 mbar ... 30 bar (0.29 ... 435 psi) Pressure transmitters for level Measured variable: Level of aggressive and non-aggressive liquids in open and closed vessels. Span (infinitely adjustable) for DS III with HART: 25 mbar ... 5 bar (0.363 ... 72.5 psi) Nominal measuring range for DS III with PROFIBUS PA and FOUNDATION Fieldbus: 250 mbar ... 5 bar (3.63 ... 72.5 psi) Nominal diameter of the mounting flange • DN 80 or DN 100 • 3 inch or 4 inch In the case of level measurements in open containers, the lowpressure connection of the measuring cell remains open (measurement "compared to atmospheric"). In the case of measurements in closed containers, the lowerpressure connection has to be connected to the container in order to compensate the static pressure. The wetted parts are made from a variety of materials, depending on the degree of corrosion resistance required. 3 4 5 Front view The transmitter consists of various components depending on the order. The possible versions are listed in the ordering information. The components described below are the same for all transmitters. The rating plate (7, Figure "Front view") with the Article No. is located on the side of the housing. The specified number together with the ordering information provide details on the optional design details and on the possible measuring range (physical properties of built-in sensor element). The approval label is located on the opposite side. The housing is made of die-cast aluminium or stainless steel precision casting. A round cover (6) is screwed on at the front and rear of the housing. The front cover can be fitted with a viewing pane so that the measured values can be read directly on the display. The inlet (8) for the electrical connection is located either on the left or right side. The unused opening on the opposite side is sealed by a blanking plug. The protective earth connection is located on the rear of the housing. The electrical connections for the power supply and screen are accessible by unscrewing the rear cover. The bottom part of the housing contains the measuring cell with process connection (5). The measuring cell is prevented from rotating by a locking screw (4). As the result of this modular design, the measuring cell and the electronics can be replaced separately from each other. The set parameter data are retained. At the top of the housing is a plastic cover (1), which hides the input keys. Example for an attached measuring point label Y01 or Y02 = max. 27 char. Y15 = max. 16 char. Y99 = max. 10 char. Y16 = max. 27 char. .... to .... mbar Measuring point number (TAG No.) 1234 Measuring point text Siemens FI 01 · 2015 US Edition 1/91 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Technical description ■ Function Operation of electronics with HART communication Operation of electronics with PROFIBUS PA communication 9 8 9 8 0.0.0.0.0 00 M 0.0.0.0.0 00 M 10 4 5 2 3 4 IA, UH μC 5 μC 7 PA interface 7 HART interface EEPROM EEPROM Electronics Electronics 6 Sensor 1 Sensor pe Measuring cell 1 2 3 4 5 6 Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Digital-to-analog converter One non-volatile memory each in the measuring cell and electronics 7 HART interface 8 Three input keys (local operation) 9 Digital display 10 Diode circuit and connection for external ammeter IA Output current UH Power supply Pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in a microcontroller, its linearity and temperature response corrected, and converted in a digital-to-analog converter (5) into an output current of 4 to 20 mA. The diode circuit (10) protects against incorrect polarity. The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the 3 input keys (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The HART modem (7) permits parameterization using a protocol according to the HART specification. The pressure transmitters with spans 63 bar measure the input pressure compared to atmosphere, transmitters with spans 160 bar compared to vacuum. 1/92 Siemens FI 01 · 2015 US Edition 6 pe 1 2 3 4 5 6 7 Power supply unit Coupler 11 12 EEPROM 1 6 6 Power supply 10 PROFIBUS DP 3 PROFIBUS-PA 2 EEPROM 1 BusMaster Measuring cell Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics PROFIBUS-PA interface 8 9 10 11 12 Three input keys (local operation) Digital display Power supply DP/PA coupler or link Bus master pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of the electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the PROFIBUS PA through an electrically isolated PA interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the PROFIBUS PA. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as SIMATIC PDM is required for this. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Technical description Operation of electronics with FOUNDATION Fieldbus communication Mode of operation of the measuring cells Measuring cell for gauge pressure 9 8 0.0.0.0.0 00 2 3 4 5 5 4 7 FF interface μC EEPROM 6 Foundation Fieldbus M 3 Power supply unit Coupler Electronics Sensor 7 Measuring cell sensor Instrument amplifier Analog-to-digital converter Microcontroller Electrical isolation One non-volatile memory each in the measuring cell and electronics FF interface Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable pe Measuring cell for gauge pressure, function diagram pe Measuring cell 1 2 3 4 5 6 1 2 3 4 5 pe 2 6 EEPROM 1 1 Power supply 10 8 9 10 Three input keys (local operation) Digital display Power supply pe Input variable Function diagram of electronics The bridge output voltage created by the sensor (1, Figure "Function diagram of electronics") is amplified by the measuring amplifier (2) and digitized in the analog-to-digital converter (3). The digital information is evaluated in the microcontroller, its linearity and temperature response corrected, and provided on the FOUNDATION Fieldbus through an electrically isolated FOUNDATION Fieldbus interface (7). The data specific to the measuring cell, the electronics data, and the parameter data are stored in the two non-volatile memories (6). The one memory is coupled to the measuring cell, the other to the electronics. As the result of this modular design, the electronics and the measuring cell can be replaced separately from each other. Using the three input buttons (8) you can parameterize the pressure transmitter directly at the measuring point. The input buttons can also be used to control the view of the results, the error messages and the operating modes on the display (9). The results with status values and diagnostic values are transferred by cyclic data transmission on the FOUNDATION Fieldbus. Parameterization data and error messages are transferred by acyclic data transmission. Special software such as National Instruments Configurator is required for this. The pressure pe is applied through the process connection (2, Figure "Measuring cell for gauge pressure, function diagram) to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. Measuring cell for gauge pressure with front-flush diaphragm 5 4 1 1 2 3 4 5 pe Measuring cell Process connection Seal diaphragm Filling liquid Silicon pressure sensor Pressure as input variable 2 3 pe Measuring cell for gauge pressure, with front-flush diaphragm for paper industry, function diagram The pressure pe is applied through the process connection (2, Figure "Measuring cell for gauge pressure, with front-flush diaphragm for paper industry, function diagram") to the measuring cell (1). This pressure is subsequently transmitted further through the seal diaphragm (3) and the filling liquid (4) to the silicon pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. Siemens FI 01 · 2015 US Edition 1/93 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III - Technical description Measuring cell for absolute pressure from gauge pressure series Measuring cell for differential pressure and flow 2 3 4 1 2 3 4 5 6 7 5 4 3 1 1 2 3 4 5 1 pe 2 pe Measuring cell Process connection Seal diaphragm Filling liquid Silicon absolute pressure sensor Absolute pressure as input variable Measuring cell for absolute pressure from the pressure series, function diagram The absolute pressure pe is transmitted through the seal diaphragm (3, Figure "Measuring cell for absolute pressure from pressure series, gauge pressure, function diagram ") and the filling liquid (4) to the silicon absolute pressure sensor (5) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. Measuring cell for absolute pressure from differential pressure series 1 + - 5 7 Seal diaphragm O-ring Overload diaphragm Silicon pressure sensor Process flange Body of measuring cell Filling liquid 6 Measuring cell for differential pressure and flow, function diagram The differential pressure is transmitted through the seal diaphragms (1, Figure "Measuring cell for differential pressure and flow, function diagram") and the filling liquid (7) to the silicon pressure sensor (4). The measuring diaphragm is flexed by the applied differential pressure. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (3) is flexed until the seal diaphragm rests on the body of the measuring cell (6), thus protecting the silicon pressure sensor from overloads. Measuring cell for level 2 3 4 5 1 pe 6 8 7 1 2 3 4 5 6 7 8 pe Reference vacuum Overload diaphragm Silicon pressure sensor O-ring Process flange Seal diaphragm Body of measuring cell Filling liquid Absolute pressure as input variable Measuring cell for absolute pressure from differential pressure series, function diagram The input pressure pe is transmitted through the seal diaphragm (6, Figure "Measuring cell for absolute pressure from differential pressure series, function diagram") and the filling liquid (8) to the silicon pressure sensor (3). The difference in pressure between the input pressure pe and the reference vacuum (1) on the low-pressure side of the measuring cell flexes the measuring diaphragm. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the absolute pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (2) is flexed until the seal diaphragm rests on the body of the measuring cell (7), thus protecting the silicon pressure sensor from overloads. 3 4 5 6 7 2 8 + - 1 10 9 1 2 3 4 5 Flange with tube Seal diaphragm on mounting flange Seal diaphragm Body of measuring cell Overload diaphragm 6 7 8 9 10 Silicon pressure sensor O-ring Process flange Filling liquid Capillary with filling liquid of mounting flange Measuring cell for level, function diagram The input pressure (hydrostatic pressure) acts hydraulically on the measuring cell through the seal diaphragm on the mounting flange (2, Figure "Measuring cell for level, function diagram"). This differential pressure is subsequently transmitted further through the measuring cell (3) and the filling liquid (9) to the silicon pressure sensor (6) whose measuring diaphragm is then flexed. This changes the resistance of the four piezo-resistors fitted in the diaphragm in a bridge circuit. This change in resistance results in a bridge output voltage proportional to the differential pressure. An overload diaphragm is installed to provide protection from overloads. If the measuring limits are exceeded, the overload diaphragm (5) is flexed until the seal diaphragm rests on the body of the measuring cell (4), thus protecting the silicon pressure sensor from overloads. 1/94 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Technical description Parameterization DS III Depending on the version, there are a range of options for parameterizing the pressure transmitter and for setting or scanning the parameters. Parameterization using the input buttons (local operation) With the input buttons you can easily set the most important parameters without any additional equipment. Parameterization using HART Parameterization using HART is performed with a HART Communicator or a PC. + 230 ... 1100 Ω SITRANS P transmitter Power supply HART communicator Communication between a HART Communicator and a pressure transmitter When parameterizing with the HART Communicator, the connection is made directly to the 2-wire cable. + 230 ... 500 Ω SITRANS P transmitter HART modem Power supply Diagnostic functions for DS III with HART • Zero correction display • Event counter • Limit transmitter • Saturation alarm • Slave pointer • Simulation functions • Maintenance timer Available physical units of display for DS III with HART Table style: Technical specifications 2 Physical variable Physical dimensions Pressure (setting can also be Pa, MPa, kPa, bar, mbar, torr, atm, psi, made in the factory) g/cm2, kg/cm2, inH2O, inH2O (4 °C), mmH2O, ftH2O (20 °C), inHg, mmHg Level (height data) m, cm, mm, ft, in Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid Mass g, kg, t, lb, Ston, Lton, oz volume flow m3/d, m3/h, m3/s, l/min, l/s, ft3/d, ft3/min, ft3/s, US gallon/min, US gallon/s Mass flow t/d, t/h, t/min, kg/d, kg/h, kg/min, kg/s, g/d, g/h, g/min, g/s, lb/d, lb/h, lb/min, lb/s, LTon/d, LTon/h, STon/d, STon/h, STon/min Temperature K, °C, °F, °R Miscellaneous %, mA Parameterization through PROFIBUS PA interface Fully digital communication through PROFIBUS PA, profile 3.0, is particularly user-friendly. Through the PROFIBUS the DS III with PROFIBUS PA is connected to a process control system, e. g. SIMATIC PSC 7. Communication is possible even in a potentially explosive environment. PC or laptop USB/RS 232 For parameterization through PROFIBUS you need suitable software, e.g. SIMATIC PDM (Process Device Manager). HART communication between a PC communicator and a pressure transmitter Parameterization through FOUNDATION Fieldbus interface When parameterizing with a PC, the connection is made through a HART modem. Fully digital communication through FOUNDATION Fieldbus is particularly user-friendly. Through the FOUNDATION Fieldbus the DS III with FOUNDATION Fieldbus is connected to a process control system. Communication is possible even in a potentially explosive environment. The signals needed for communication in conformity with the HART 5.x or 6.x protocols are superimposed on the output current using the Frequency Shift Keying (FSK) method. Adjustable parameters, DS III with HART For parameterization through the FOUNDATION Fieldbus you need suitable software, e.g. National Instruments Configurator. Parameters Input keys (DS III HART) HART communication Adjustable parameters for DS III with PROFIBUS PA and FOUNDATION Fieldbus Start of scale Full-scale value Electrical damping Start-of-scale value without application of a pressure ("Blind setting") Full-scale value without application of a pressure ("Blind setting") Zero adjustment current transmitter Fault current Disabling of buttons, write protection Type of dimension and actual dimension Characteristic (linear / squarerooted) Input of characteristic Freely-programmable LCD Diagnostic functions x x x x x x x x Parameters Input keys PROFIBUS PA and FOUNDATION Fieldbus interface x x Electrical damping x x Zero adjustment (correction of position) x x Buttons and/or function disabling x x Source of measured-value display x x Physical dimension of display x x 1) 2) Cancel apart from write protection Only differential pressure x x x x x x x x1) x x Position of decimal point x x x2) x2) Bus address x x Adjustment of characteristic x x x x x Input of characteristic x Freely-programmable LCD x Diagnostics functions x Siemens FI 01 · 2015 US Edition 1/95 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III - Technical description Diagnostic functions for DS III with PROFIBUS PA and FOUNDATION Fieldbus • Event counter • Slave pointer • Maintenance timer • Simulation functions • Display of zero correction • Limit transmitter • Saturation alarm Physical dimensions available for the display Physical variable Physical dimensions Pressure (setting can also be MPa, kPa, Pa, bar, mbar, torr, atm, psi, g/cm2, kg/cm2, mmH2O, mmH2O (4 °C), made in the factory) inH2O, inH20 (4 °C), ftH2O (20 °C), mmHg, inHg Level (height data) m, cm, mm, ft, in, yd Volume m3, dm3, hl, yd3, ft3, in3, US gallon, lmp. gallon, bushel, barrel, barrel liquid volume flow m3/s, m3/min, m3/h, m3/d, l/s, l/min, l/h, l/ d, Ml/d, ft3/s, ft3/min, ft3/h, ft3/d, US gallon/s, US gallon/min, US gallon/h, US gallon/d, bbl/s, bbl/min, bbl/h, bbl/d Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, /t/d, lb/s, lb/min, lb/h, lb/d, STon/s, STon/min, STon/h, STon/d, LTon/s, LTon/min, LTon/h, LTon/d Total mass flow t, kg, g, lb, oz, LTon, STon Temperature K, °C, °F, °R Miscellaneous % 1/96 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge pressure ■ Technical specifications SITRANS P, DS III series for gauge pressure HART PROFIBUS PA and FOUNDATION Fieldbus Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Gauge pressure Span (min. ... max.) Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar (0.15 ... 14.5 psi) 6 bar (87 psi) 1 bar (14.5 psi) 6 bar (87 psi) 0.04 ... 4 bar (0.58 ... 58 psi) 10 bar (145 psi) 4 bar (58 psi) 10 bar (145 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 32 bar (464 psi) 16 bar (232 psi) 32 bar (464 psi) 0.6 ... 63 bar (9.14 ... 914 psi) 100 bar (1450 psi) 63 bar (914 psi) 100 bar (1450 psi) 1.6 ... 160 bar (23.2 ... 2320 psi) 250 bar (3626 psi) 160 bar (2320 psi) 250 bar (3626 psi) 4.0 ... 400 bar (58 ... 5802 psi) 600 bar (8700 psi) 400 bar (5802 psi) 600 bar (8700 psi) 7.0 ... 700 bar (102 ... 10153 psi) 800 bar (11603 psi) 700 bar (10153 psi) 800 bar (11603 psi) Lower measuring limit • Measuring cell with silicone oil filling • Measuring cell with inert filling liquid 30 mbar a (0.44 psia) 30 mbar a (0.44 psia) Upper measuring limit 100 % of max. span (for oxygen version and inert filling liquid; max. 120 bar (1740 psi)) Output Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Load Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Acc. to IEC 60770-1 Measuring accuracy Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Span ratio r = max. span/set span Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - r 10 (0.0029 r + 0.071) % (0.0029 r + 0.071) % - 10 < r 30 (0.0045 r + 0.071) % (0.0045 r + 0.071) % - 30 < r 100 (0.005 r + 0.05) % (0.005 r + 0.05) % • 1 ... 4-bar measuring cell (0.25 r) % per 5 years (0.25 r) % per 5 years • 16 ... 700-bar measuring cell (0.125 r) % per 5 years (0.125 r) % per 5 years • at -10 ... +60 °C (14 ... 140 °F) (0.08 r + 0.1) %1) (at 700 bar: (0.1 r + 0.2) %2) (0.08 r + 0.1) %1) (at 700 bar: (0.1 r + 0.2) %2) • at -40 ... -10 °C and +60 ... +85 °C (-40 ... +14 °F and 140 ... 185 °F) (0.1 r + 0.15) %/10 K (0.1 r + 0.15) %/10 K Measured Value Resolution - 3 10-5 of nominal measuring range Long-term stability (temp.erature change 30 °C ( 54 °F)) Influence of ambient temperature Siemens FI 01 · 2015 US Edition 1/97 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge pressure SITRANS P, DS III series for gauge pressure HART PROFIBUS PA and FOUNDATION Fieldbus Rated conditions Degree of protection (to EN 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design Die-cast aluminum: 2.0 kg ( 4.4 lb) Stainless steel precision casting: 4.6 kg ( 10.1 lb) Weight (without options) Enclosure material Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Connection shank Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4610 Stainless steel, mat. no. 1.4404/316L • Oval flange • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection Connection shank G½B to DIN EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MAWP 2320 psi)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to EN 61518 Material of mounting bracket Steel Sheet-steel, Mat. No. 1.0330, chrome-plated Sheet stainless steel, mat. no. 1.4301 (SS 304) Stainless steel Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Bus voltage Current consumption 1/98 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge pressure SITRANS P, DS III series for gauge pressure HART PROFIBUS PA and FOUNDATION Fieldbus Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Marking - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 174 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature - Connection -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 To circuits with values: UH = 10.5 ... 45 V DC • Dust explosion protection for zone 20 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 01 ATEX 2055 • Dust explosion protection for zone 21/22 - Marking - Connection Ex II 2 D IP65 T 120 °C To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connections (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) L i = 7 H, Ci = 1.1 nF Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III 1) Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.064 . r + 0.08) % / 28 °C (50 °F). 2) Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.08 . r + 0.16) % / 28 °C (50 °F). Siemens FI 01 · 2015 US Edition 1/99 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge pressure HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function 1/100 Siemens FI 01 · 2015 US Edition - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge pressure Selection and Ordering data Article No. Selection and Ordering data Article No. Pressure transmitter for gauge pressure, SITRANS P DS III with HART 7MF 4 0 3 3 - Pressure transmitter for gauge pressure, SITRANS P DS III with HART 7MF 4 0 3 3 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Measuring span (min. ... max.) 0.01 ... 1 bar (0.15 ... 14.5 psi) 0.04 ... 4 bar (0.58 ... 58 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 0.63 ... 63 bar (9.14 ... 914 psi) 1.6 ... 160 bar (23.2 ... 2320 psi) 4.0 ... 400 bar (58.0 ... 5802 psi) 7.0 ... 700 bar (102.0 ...10153 psi) 1 3 0 1 • With visible display (setting: mA) 6 • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 7 Power supply units see Chap. 7 "Supplementary Components". B C D E F G J Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation 1) For oxygen application, add Order code E10. 2) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-.... and 7MF4900-1...-.B 5) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 6) Not in conjunction with Electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 7) Without cable gland, with blanking plug 8) With enclosed cable gland Ex ia and blanking plug 9) Configurations with HAN and M12 connectors are only available in Ex ic. Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 2) 3) 4) 5) Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting6) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"7) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"8) - "Ex nA/ic (Zone 2)"9) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"8)10) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)10) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"7) Electrical connection / cable entry • Screwed gland Pg 13.5 (adapter)11) • Screwed gland M20 x1 .5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector11) • M12 connectors (stainless steel)11)12) 77777 - 7777 Display • Without display • Without visible display (display concealed, setting: mA) A B C Y 0 1 2 3 4 5 6 10) Only in connection with IP65. 11) Only in connection with Ex approval A, B or E. 12) M12 delivered without cable socket 0 3 1 2 A B D P E R F S NC A B C D F Siemens FI 01 · 2015 US Edition 1/101 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge pressure Article No. Selection and Ordering data Selection and Ordering data Pressure transmitter for gauge pressure SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 0 3 4 - SITRANS P DS III with PROFIBUS PA (PA) SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 0 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Nominal measuring range 1 bar (14.5 psi) 4 bar (58 psi) 16 bar (232 psi) 63 bar (914 psi) 160 bar (2320 psi) 400 bar (5802 psi) 700 bar (10153 psi) 77777 - 7777 1 3 Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) A B C Y 0 1 2 3 4 5 6 0 3 1 2 Explosion protection A • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"7) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"8) - "Ex nA/ic (Zone 2)"9) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"8) 10) (not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)10) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"7) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)11) 12) 1/102 Siemens FI 01 · 2015 US Edition 7MF 4 0 3 5 77777 - 7777 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Wetted parts materials Seal diaphragm Process connection Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) 6) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT 7MF 4 0 3 4 - Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • with customer-specific display (setting as specified, Order code "Y21" required) B C D E F G J Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 2) 3) 4) 5) Article No. Pressure transmitter for gauge pressure B D P E R F S NC B C F 1) For oxygen application, add Order code E10. 2) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-.... and 7MF4900-1...-.B 5) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 6) M10 fastening thread: Max. span 160 bar (2320 psi) 7/16-20 UNF and M12 fastening thread: Max. span 400 bar (5802 psi) 7) Without cable gland, with blanking plug. 8) With enclosed cable gland Ex ia and blanking plug. 9) Configurations with HAN and M12 connectors are only available in Ex ic. 10) Only in connection with IP65. 11) M12 delivered without cable socket. 12) Only in connection with Ex approval A, B, E or F. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge pressure Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Cable sockets for M12 connectors (metal (CuZn)) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) Selection and Ordering data HART PA A01 A02 A30 A31 A32 A33 A50 FF Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E254) "Flameproof" explosion protection according to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) E264) Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E284) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E454) Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E464) Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E554) E564) B11 B12 B13 B14 B16 English rating plate Pressure units in inH20 and/or psi B21 Explosion protection "Explosion-proof" to NEPSI (China) (only for transmitter 7MF4...-.....-.D..) Quality inspection certificate (Five-step factory calibration) to IEC 60770-21) C11 Ex protection "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) E574) Inspection certificate2) Acc. to EN 10204-3.1 C12 E584) Factory certificate Acc. to EN 10204-2.2 C14 Ex protection „Ex ia“, „Ex d“ and „Zone 2“ to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) E704) Functional safety (SIL2) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) C213) Two coats of lacquer on casing and cover (PU on epoxy) G10 Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C23 Transient protector 6 kV (lightning protection) J01 Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Oval flange NAM (ASTAVA) J06 Device passport Russia (For price request please contact the technical support www.siemens.com/automation/supportrequest) C99 Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) D07 Degree of protection IP66/IP68 (only for M20x1.5 and ½-14 NPT) D12 Supplied with oval flange (1 item), PTFE packing and screws in thread of oval flange D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“ and IP65) E01 Oxygen application (In the case of oxygen measurement and inert liquid max. 100 bar (1450 psi) at 60°C (140 °F)) E10 Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H 4) Option does not include ATEX approval, but instead includes only the country-specific approval. Siemens FI 01 · 2015 US Edition 1/103 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge pressure Selection and Ordering data Order code Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. HART PA FF Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Y17 Setting of pressure indication in pressure units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Y21 Setting of pressure indication in non-pressure units2) Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Y22 + Y01 Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Max. 8 characters, specify in plain text: Y17: ........................................... Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available Ordering example Item line: 7MF4033-1EA00-1AA7-Z B line: A01 + Y01 + Y21 C line: Y01: 10 ... 20 bar (145 ... 290 psi) C line: Y21: bar (psi) 1) 2) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Preset values can only be changed over SIMATIC PDM. 1/104 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge pressure 53 (2.1) 54 (2.13) 27 (1.1) Ø80 (3.15) 2 17 (0.67) 29 (1.14) 4) 5 84 (3.31) 6 3 4 3 7 9 72 (2.8) 8 120 (4.72) 68 (2.68) SW 36 approx. 40 (1.6) 171 (6.7) approx. 96 (3.78) 176 (6.93) 237 (9.33) 143 (5.6) 74 (2.9) 50 (1.97) 117 (4.61) 15 (0.6) 1 24 (0.94) ■ Dimensional drawings Space for rotation of housing min. 90 (3.54) 5) 123 (4.84) Ø50 ... 60 (1.97 ... 2.36) 105 (4.13) Electronic side, digital display (longer overall length for cover with window)1) 5 Protective cover over keys 6 Blanking plug 2 Terminal side1) 7 3 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/Han 8D2) 3) plug Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Process connection: Connection shank G½B or Oval flange 9 Mounting bracket (option) 1 4 Harting adapter 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) Minimum distance for rotating SITRANS P DS III pressure transmitters for gauge pressure, dimensions in mm (inch) Siemens FI 01 · 2015 US Edition 1/105 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm ■ Technical specifications SITRANS P DS III series for gauge and absolute pressure, with front-flush diaphragm HART PROFIBUS PA and FOUNDATION Fieldbus Input of gauge pressure, with front-flush diaphragm Measured variable Gauge pressure, front-flush Spans (infinitely adjustable) or nominal measur- Span (min. ... max.) ing range and max. permissible test pressure Max. perm. test pressure Nominal measuring range Max. perm. test pressure 0.01 ... 1 bar (0.15 ... 14.5 psi) 6 bar (87 psi) 1 bar (14.5 psi) 6 bar (87 psi) 0.04 ... 4 bar (0.58 ... 58 psi) 10 bar (145 psi) 4 bar (58 psi) 10 bar (145 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 32 bar (464 psi) 16 bar (232 psi) 32 bar (464 psi) 0.6 ... 63 bar (9.14 ... 914 psi) 100 bar (1450 psi) 63 bar (914 psi) 100 bar (1450 psi) Lower measuring limit Upper measuring limit 100 mbar a (1.45 psia) 100 % of max. span 100 % of the max. nominal measuring range Input of absolute pressure, with front-flush diaphragm Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Absolute pressure, front-flush Span (min. ... max.) Max. perm. test pressure Nominal measuring range Max. perm. test pressure 43 ... 1300 mbar a (0.62 ... 18.85 psia) 10 bar a (145 psia) 1300 mbar a (18.85 psia) 10 bar a (145 psia) 0.16 ... 5 bar a (2.32 ... 72.5 psia) 30 bar a (435 psia) 5 bar a (72.5 psia) 30 bar a (435 psia) 1 ... 30 bar a (14.5 ... 435 psia) 100 bar a (1450 psia) 30 bar a (435 psia) 100 bar a (1450 psia) Lower measuring limit Upper measuring limit 0 bar a (0 psia) 100 % of max. span 100 % of the max. nominal measuring range Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Output Load Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Acc. to IEC 60770-1 Measuring accuracy Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Span ratio r = max. span/set span Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility Gauge pressure, front-flush Absolute pressure, front-flush Gauge pressure, front-flush Absolute pressure, front-flush • Linear characteristic - r 10 (0.0029 r + 0.071) % 0.2 % (0.0029 r + 0.071) % 0.2 % - 10 < r 30 (0.0045 r + 0.071) % 0.4 % (0.0045 r + 0.071) % 0.4 % - 30 < r 100 (0.005 r + 0.05) % (0.005 r + 0.05) % Long-term stability (temperature change 30 °C ( 54 °F)) 1/106 Siemens FI 01 · 2015 US Edition (0.25 r) % per 5 years - (0.25 r) % per 5 years - © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm SITRANS P DS III series for gauge and absolute pressure, with front-flush diaphragm HART PROFIBUS PA and FOUNDATION Fieldbus Gauge pressure, front-flush Absolute pressure, front-flush Gauge pressure, front-flush Absolute pressure, front-flush • at -10 ... +60 °C (14 ... 140 °F) (0.1 r + 0.2) %1) (0.2 r + 0.3) % (0.1 r + 0.2) %1) (0.2 r + 0.3) % • at -40 ... -10 °C and 60 ... 85 °C (-40 ... +14 °F and 140 ... 185 °F) (0.1 r + 0.15) %/10 K (0.2 r + 0.3) %/10 K (0.1 r + 0.15) %/10 K (0.2 r + 0.3) %/10 K Influence of ambient temperature Influence of mounting position Measured Value Resolution 0.1 mbar (0.04 inH2O) per 10° inclination - 3 10-5 of nominal measuring range Influence of the medium temperature • Temperature difference between medium temperature and ambient temperature 3 mbar/10 K (0.04 psi/10 K) Rated conditions Installation conditions Ambient temperature Observe the temperature class in areas subject to explosion hazard. • Measuring cell with silicone oil -40 ... +85 °C (-40 ... +185 °F) • Measuring cell with Neobee oil (with front-flush diaphragm) -10 ... +85 °C (14 ... +185 °F) • Measuring cell with inert liquid (not with frontflush diaphragm) -20 ... +85 °C (-4 ... +185 °F) • Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) • Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) (in the case of Neobee: -20 ... +85 °C (-4 ... +185/°F)) (for high temperature oil: -10 ... + 85 °C (14 ... 185 °F)) • Climatic class - Condensation Degree of protection (to IEC 60529) Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics IP66 (optional IP66/IP68), NEMA 4X • Electromagnetic Compatibility - Emitted interference and interference immunity Medium conditions Acc. to IEC 61326 and NAMUR NE 21 The max. medium temperature of the front-flush process connections is to be taken into account in accordance with the relevant connection standards (e. g. DIN 32676, DIN 11851 etc.). Temperature of medium • Measuring cell with silicone oil -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with silicone oil (with front-flush diaphragm) -40 ... +150 °C (-40 ... +302 °F) • Measuring cell with Neobee oil (with front-flush diaphragm) -10 ... +150 °C (14 ... 302 °F) • Measuring cell with silicone oil, with temperature decoupler (only for gauge pressure version with front-flush diaphragm) -40 ... +200 °C (-40 ... +392 °F) • Measuring cell with Neobee oil, with temperature decoupler (only for gauge pressure version with flush-mounted diaphragm) -10 ... +200 °C (14 ... 392 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • Measuring cell with high-temperature oil (only for gauge pressure version with front-flush diaphragm) -10 ... +250 °C (14 ... 482 °F) Design Weight (without options) Enclosure material Wetted parts materials 1.5 kg ( 3.3 lb) Low-copper die-cast aluminum, GD-AlSi12 or stainless steel precision casting, mat. no. 1.4408 Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 Measuring cell filling Silicone oil or inert filling liquid Process connection • Flanges as per EN and ASME • F&B and pharmaceutical flanges Surface quality touched-by-media Ra-values 0.8 µm (32 µ-inch)/welds Ra) 1.6 µm (64 µ-inch) (Process connections acc. to 3A; Ra-values 0.8 µm (32 µ-inch)/welds Ra) 0.8 µm (32 µ-inch) Siemens FI 01 · 2015 US Edition 1/107 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm SITRANS P DS III series for gauge and absolute pressure, with front-flush diaphragm HART PROFIBUS PA and FOUNDATION Fieldbus Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Bus voltage Current consumption • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Marking - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 99 ATEX 1160 • Explosion-proof "d" - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Permissible ambient temperature - Connection To circuits with values: UH = 10.5 ... 45 V DC To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 • Dust explosion protection for zone 20 - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 01 ATEX 2055 • Dust explosion protection for zone 21/22 - Marking Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connections (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF 1/108 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm SITRANS P DS III series for gauge and absolute pressure, with front-flush diaphragm HART PROFIBUS PA and FOUNDATION Fieldbus Certificates and approvals (continued) • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 1) Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.064 . r + 0.08) % / 28 °C (50 °F). Hygiene version In the case of SITRANS P DSIII with 7MF413x front-flush diaphragm, selected connections comply with the requirements of EHEDG. Siemens FI 01 · 2015 US Edition 1/109 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function 1/110 Siemens FI 01 · 2015 US Edition - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Selection and Ordering data Article No. Pressure transmitter for gauge and absolute pressure, front-flush diaphragm, SITRANS P DS III HART 77777 - 7777 7MF 4 1 3 3 - Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid FDA compliant fill fluid • Neobee oil Measuring cell cleaning normal grease-free to cleanliness level 2 1 3 normal 4 Measuring span (min. ... max.) 0.01 ... 1 bar (0.15 ... 14.5 psi) 0.04 ... 4 bar (0.58 ... 58 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 0.63 ... 63 bar (9.14 ... 914 psi) B C D E 43 ... 1300 mbar a1) 0.16 ... 5 bar a1) 1 ... 30 bar a1) S T U (0.62 ... 18.85 psia)1) (0.7 ... 72.5 psia)1) (4.35 ... 435 psia)1) 1) Not with temperature decoupler P00 and P10, not for process connections R02, R04, R10 and R11, and can only be ordered in conjunction with silicone oil. 2) Only available for flanges with options M.., N.. and Q.. 3) Without cable gland, with blanking plug 4) Configurations with HAN and M12 connectors are only available in Ex ic. 5) Only in connection with IP65. 6) Only in connection with Ex approval A, B or E. 7) Only in connection with Ex approval A, B, E or F. 8) M12 delivered without cable socket Wetted parts materials Seal diaphragm Connection shank Stainless steel Hastelloy2) Stainless steel Stainless steel Process connection • Flange version with Order code M.., N.., R.. or Q.. Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting A B 7 0 3 Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)" 3) - „Ex nA/ic (Zone 2)“4) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)5) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"3) Electrical connection/cable entry • Inner thread M20 x 1.5 • Female thread ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector6) • M12 connectors (stainless steel)7) 8) 1 2 A B D E F S NC B C D F Display • Without display • Without visible display (display concealed, setting: mA) 0 1 • With visible display (setting: mA) 6 • With customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 7 Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Siemens FI 01 · 2015 US Edition 1/111 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Selection and Ordering data Article No. Selection and Ordering data Pressure transmitter P for gauge and absolute pressure, front-flush diaphragm: SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 1 3 4 - SITRANS P DS III with PROFIBUS PA (PA) SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 1 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid FDA compliant fill fluid • Neobee oil Measuring cell cleaning normal grease-free to cleanliness level 2 normal Nominal measuring range 1 bar (14.5 psi) 4 bar (58 psi) 16 bar (232 psi) 63 bar (914 psi) 1300 mbar a1) (18.85 psia)1) 5 bar a1) (72.5 psia)1) 30 bar a1) (435 psia)1) 77777 - 7777 Stainless steel Stainless steel Process connection • Flange version with Order code M.., N.., R.. or Q.. Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"3) - „Ex nA/ic (Zone 2)“4) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)5) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"3) (Available soon) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)6) 7) 1/112 Siemens FI 01 · 2015 US Edition 7MF 4 1 3 4 7MF 4 1 3 5 77777 - 7777 Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) 1 3 4 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation B C D E S T U Wetted parts materials Seal diaphragm Connection shank Stainless steel Hastelloy2) Article No. Pressure transmitter P for gauge and absolute pressure, front-flush diaphragm: A B 7 0 3 1 2 A B D E F S NC B C F 1) Not with temperature decoupler P00 and P10, not for process connections R01, R02, R04, R10 and R11, and can only be ordered in conjunction with silicone oil. 2) Only available for flanges with options M.., N.. and Q.. 3) Without cable gland, with blanking plug 4) 5) Configurations with HAN and M12 connectors are only available in Ex ic. Only in connection with IP65. 6) Only in connection with Ex approval A, B, E or F. 7) M12 delivered without cable socket © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Cable sockets for M12 connectors (metal (CuZn)) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) Selection and Ordering data HART PA A30 A31 A32 A33 A50 FF Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Explosion-proof "Intrinsic safety" to NEPSI E552) (China) (only for transmitter 7MF4...-.....-.B..) Explosion protection "Explosion-proof" to E562) NEPSI (China) (only for transmitter 7MF4...-.....-.D..) E572) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ E582) to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E702) Ex protection "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) B11 B12 B13 B14 B16 English rating plate Pressure units in inH20 and/or psi B21 Quality inspection certificate (Five-step factory calibration) to IEC 60770-2 C11 Two coats of lacquer on casing and cover (PU on epoxy) G10 Inspection certificate Acc. to EN 10204-3.1 C12 Transient protector 6 kV (lightning protec- J01 tion) Factory certificate Acc. to EN 10204-2.2 C14 Functional safety (SIL2) C20 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C211) Functional safety (SIL2/3) C23 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Device passport Russia C99 Setting of upper limit of output signal to 22.0 mA D05 Degree of protection IP66/IP68 (only for M20x1.5 and ½-14 NPT) D12 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 Oxygen application E10 (In the case of oxygen measurement and inert liquid max. 100 bar (1450 psi) at 60°C (140 °F)) Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) to E252) INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) "Flameproof" explosion protection accord- E262) ing to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E282) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E452) Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E462) (For price request please contact the technical support www.siemens.com/automation/support-request.) Flanges to EN 1092-1, Form B1 • DN 25, PN 403) • DN 25, PN 1003) • DN 40, PN 40 • DN 40, PN 100 • DN 50, PN 16 • DN 50, PN 40 • DN 80, PN 16 • DN 80, PN 40 M11 M21 M13 M23 M04 M14 M06 M16 Flanges to ASME B16.5 • Stainless steel flange 1" class 1503) • Stainless steel flange 1½" class 150 • Stainless steel flange 2" class 150 • Stainless steel flange 3" class 150 • Stainless steel flange 4" class 150 • Stainless steel flange 1" class 3003) • Stainless steel flange 1½" class 300 • Stainless steel flange 2" class 300 • Stainless steel flange 3" class 300 • Stainless steel flange 4" class 300 M40 M41 M42 M43 M44 M45 M46 M47 M48 M49 Threaded connector to DIN 3852-2, form A, thread to ISO 2284) • G ¾"-A, front-flush • G 1"-A, front-flush • G 2"-A, front-flush R01 R02 R04 Tank connection5) Sealing is included in delivery • TG 52/50, PN 40 • TG 52/150, PN 40 R10 R11 Sanitary process connection according DIN 11851 (Dairy connection with slotted union nut) • DN 50, PN 25 • DN 80, PN 25 N04 N06 Tri-Clamp connection according DIN 32676/ISO 2852 • DN 50/2", PN 16 • DN 65/3", PN 10 N14 N15 N28 Varivent connection Certified to EHEDG • Type N = 68 for Varivent housing DN 40 ... 125 und 1½" ... 6", PN 40 Siemens FI 01 · 2015 US Edition 1/113 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Temperature decoupler up to 200 °C6) for version with front-flush diaphragm Selection and Ordering data HART PA Further designs Add "-Z" to Article No. and specify Order code. Aseptic threaded socket to DIN 11864-1 Form A approved according to EHEDG • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 25 • DN 100, PN 25 N33 N34 N35 N36 Aseptic flange with notch to DIN 11864-2 Form A approved according to EHEDG • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 N43 N44 N45 N46 N43 + P11 N44 + P11 N45 + P11 N46 + P11 N53 N54 N55 N56 P00 Temperature decoupler up to 250 °C P10 Measuring cell filling: High-temperature oil, only in conjunction with measuring cell filling silicone oil Sanitary process connection to DRD • DN 50, PN 40 M32 SMS socket with union nut • 2“ • 2½“ • 3“ M67 M68 M69 SMS threaded socket • 2“ • 2½“ • 3“ M73 M74 M75 M82 M83 M84 IDF threaded socket ISO 2853 • 2“ • 2½“ • 3“ M92 M93 M94 Q05 Q06 Q07 Q08 Q13 Q14 Q15 Q16 Sanitary process connection to NEUMO Bio-Connect flange connection Certified to EHEDG • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2", PN 16 • DN 2½", PN 16 • DN 3", PN 16 • DN 4", PN 16 Q23 Q24 Q25 Q26 Q31 Q32 Q33 Q34 Sanitary process connection to NEUMO Bio-Connect clamp connection Certified to EHEDG • DN 50, PN 16 • DN 65, PN 10 • DN 80, PN 10 • DN 100, PN 10 • DN 2½", PN 16 • DN 3", PN 10 • DN 4", PN 10 Q39 Q40 Q41 Q42 Q48 Q49 Q50 Sanitary process connection to NEUMO Bio-Connect S flange connection Certified to EHEDG • DN 2", PN 16 Q72 1/114 Siemens FI 01 · 2015 US Edition HART PA FF Aseptic flange with groove to DIN 11864-2 Form A approved according to EHEDG • DN 50, PN 16 IDF socket with union nut ISO 2853 • 2“ • 2½“ • 3“ Sanitary process connection to NEUMO Bio-Connect screw connection Certified to EHEDG • DN 50, PN 16 • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 • DN 2", PN 16 • DN 2½", PN 16 • DN 3", PN 16 • DN 4", PN 16 Order code FF • DN 65, PN 16 • DN 80, PN 16 • DN 100, PN 16 Aseptic clamp with groove to DIN 11864-3 FormA approved according to EHEDG • DN 50, PN 25 • DN 65, PN 25 • DN 80, PN 16 • DN 100, PN 16 1) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H. 2) Option does not include ATEX approval, but instead includes only the country-specific approval. 3) Special seal in Viton included in the scope of delivery 4) Lower measuring limit -100 mbar (1.45 psi). 5) The weldable socket can be ordered under accessories. 6) Certified to 3A and EHEDG. The maximum permissible temperatures of the medium depend on the respective cell fillings (see medium conditions). © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Y17 Setting of pressure indicator in pressure Y21 units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indication in Y22 + non-pressure units2) Y01 Specify in plain text: 3 Y22: ..... up to ..... l/min, m /h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Max. 8 characters, specify in plain text: Y17: ........................................... Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available Ordering example Item line: 7MF4133-1DB20-1AB7-Z B line: A22 + Y01 + Y21 C line: Y01: 1 ... 10 bar (14.5 ... 145 psi) C line: Y21: bar (psi) 1) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. 2) Preset values can only be changed over SIMATIC PDM. Siemens FI 01 · 2015 US Edition 1/115 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm 15 (0.6) 53 (2.1) Ø80 (3.15) 1 2 3 5 7 Space for rotation of housing 3 2 Temperature decoupler 4 84 (3.31) 50 (1.97) 1 29 (1.14) 6 H1 = approx. 130 (5.12) 143 (5.6) 74 (2.9) H 2 = approx. 55 (2.17) 15 (0.6) 24 (0.94) ■ Dimensional drawings 50 (1.97) 1 min. 90 (3.54) 2) Electronic side, digital display (longer overall length for cover with window)1) 4 Protective cover over keys 5 Blanking plug Terminal side1) 6 Electrical connection: Screwed gland M20 x 1,5 or screwed gland ½-14 NPT or M12 conector Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 7 Process connection: see flange tables 1) 2) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing 92 mm (3.6 inch) for minimum distance to permit rotation with indicator SITRANS P pressure transmitters, DS III series for gauge pressure, with front-flush diaphragm, dimensions in mm (inch) The diagram shows a SITRANS P DS III with an example of a flange. In this drawing the height is subdivided into H1 and H2. H1 = Height of the SITRANS P300 up to a defined cross-section H2 = Height of the flange up to this defined cross-section Only the height H2 is indicated in the dimensions of the flanges. 1/116 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Flanges as per EN and ASME Sanitary process screw connection to NEUMO Bio-Connect Flange to EN Order DN code H2 Order DN code D M11 M21 M13 M23 M04 M14 M06 M16 25 25 40 40 50 50 80 80 PN D H2 40 100 40 100 16 40 16 40 115 mm (4.5“) 140 mm (5.5“) 150 mm (5.9“) 170 mm (6.7“) 165 mm (6.5“) 165 mm (6.5“) 200 mm (7.9“) 200 mm (7.9“) Approx. 52 mm (2“) H2 EN 1092-1 D Order DN code H2 Order DN code M40 M41 M42 M43 M44 M45 M46 M47 M48 M49 1“ 1½“ 2“ 3“ 4“ 1“ 1½“ 2“ 3“ 4“ H2 ASME B16.5 PN D 150 150 150 150 150 300 300 300 300 300 110 mm (4.3“) Approx. 130 mm (5.1“) 52 mm (2“) 150 mm (5.9“) 190 mm (7.5“) 230 mm (9.1“) 125 mm (4.9“) 155 mm (6.1“) 165 mm (6.5“) 210 mm (8.1“) 255 mm (10.0“) H2 D H2 DIN 11851 (milk pipe union with slotted union nut) H2 N04 N06 50 80 PN D H2 25 25 92 mm (3.6“) 127 mm (5.0“) Approx. 52 mm (2“) D Q23 Q24 Q25 Q26 Q31 Q32 Q33 Q34 50 65 80 100 2“ 2½“ 3“ 4“ Order DN code Connections to DIN Order DN code H2 16 16 16 16 16 16 16 16 82 mm (3.2“) 105 mm (4.1“) 115 mm (4.5“) 145 mm (5.7“) 82 mm (3.2“) 105 mm (4.1“) 105 mm (4.1“) 145 mm (5.7“) Approx. 52 mm (2“) PN D H2 16 16 16 16 16 16 16 16 110 mm (4.3“) 140 mm (5.5“) 150 mm (5.9“) 175 mm (6.9“) 100 mm (3.9“) 110 mm (4.3“) 140 mm (5.5“) 175 mm (6.9“) Approx. 52 mm (2“) Sanitary process connection to NEUMO Bio-Connect clamp connection NuG and pharmaceutical connections D 2 Q39 Q40 Q41 Q42 Q47 Q48 Q49 Q50 50 65 80 100 2“ 2½“ 3“ 4“ PN D 16 10 10 10 16 16 10 10 77.4 mm (3.0“) Approx. 90.9 mm (3.6“) 52 mm (2“) 106 mm (4.2“) 119 mm (4.7“) 77.4 mm (3.0“) 90.9 mm (3.6“) 106 mm (4.2“) 119 mm (4.7“) H2 Sanitary process connection to NEUMO Bio-Connect S flange connection Order DN code Order DN code N14 N15 50 65 PN D H2 16 10 64 mm (2.5“) 91 mm (3.6“) Approx. 52 mm (2“) H2 Tri-Clamp nach DIN 32676 H2 50 65 80 100 2“ 2½“ 3“ 4“ D Sanitary process connection to NEUMO Bio-Connect flange connection Flanges to ASME D Q05 Q06 Q07 Q08 Q13 Q14 Q15 Q16 PN Q72 2“ PN D H2 16 125 mm (4.9“) Approx. 52 mm (2“) D Threaded connection G¾", G1" and G2" acc. to DIN 3852 D D H2 Varivent connection R01 ¾“ 60 37 mm (1.5“) R02 1“ 60 48 mm (1.9“) R04 2“ 60 78 mm (3.1“) Approx. 45 mm (1.8“) Approx. 47 mm (1.9“) Approx. 52 mm (2“) H2 Order DN code PN Other connections Order DN code H2 N28 PN D H2 40 84 mm (3.3“) Approx. 52 mm (2“) D 40 ... 125 D Sanitary process connection to DRD H2 Order DN code M32 50 PN D H2 40 105 mm (4.1“) Approx. 52 mm (2“) D Siemens FI 01 · 2015 US Edition 1/117 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for gauge/absolute pressure, with front-flush diaphragm Tank connection TG 52/50 and TG52/150 Aseptic threaded socket to DIN 11864-1 Form A PN D H2 Order DN code PN D H2 Approx. 63 mm (2.5“) Approx. 170 mm (6.7“) N33 N34 N35 N36 50 65 80 100 25 25 25 25 78 x 1/6“ 95 x 1/6“ 110 x ¼“ 130 x ¼“ Approx. 52 mm (2“) 25 40 63 mm (2.5“) R11 25 40 63 mm (2.5“) H2 R10 D H2 Order DN code D SMS socket with union nut M67 M68 M69 PN 2“ 25 2½“ 25 3“ 25 D H2 84 mm (3.3“) 100 mm (3.9“) 114 mm (4.5“) Approx. 52 mm (2“) Aseptic flange with notch to DIN 11864-2 Form A H2 H2 Order DN code D D SMS threaded socket H2 M73 M74 M75 PN 2“ 25 2½“ 25 3“ 25 H2 70 x 1/6 mm 85 x 1/6 mm 98 x 1/6 mm Approx. 52 mm (2“) D D IDF socket with union nut H2 Order DN code M82 M83 M84 PN 2“ 25 2½“ 25 3“ 25 D H2 77 mm (3“) 91 mm (3.6“) 106 mm (4.2“) Approx. 52 mm (2“) H2 M92 M93 M94 2“ 25 2½“ 25 3“ 25 D 1/118 H2 64 mm (2.5“) Approx. 77.5 mm (3.1“) 52 mm (2“) 91 mm (3.6“) D Siemens FI 01 · 2015 US Edition D H2 50 65 80 100 16 16 16 16 94 113 133 159 Approx. 52 mm (2“) N43 N44 N45 N46 Order DN code PN D H2 N43 + 50 P11 N44 + 65 P11 N45 + 80 P11 N46 + 100 P11 16 94 Approx. 52 mm (2“) 16 113 16 133 16 159 Order DN code PN D H2 50 65 80 100 25 25 16 16 77.5 91 106 130 Approx. 52 mm (2“) N53 N54 N55 N56 IDF threaded socket PN PN Aseptic clamp with groove to DIN 11864-3 Form A D Order DN code Order DN code Aseptic flange with groove to DIN 11864-2 Form A D H2 Order DN code H2 1 D © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from gauge pressure series) ■ Technical specifications SITRANS P DS III series for absolute pressure (from the gauge pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure Absolute pressure Span (min. ... max.) Max. perm. test pressure Nominal measuring range Max. perm. test pressure 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 6 bar a (87 psia) 250 mbar a (3.6 psia) 6 bar a (87 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psi a) 10 bar a (145 psia) 1300 mbar a (18.9 psi a) 10 bar a (145 psia) 160 ... 5000 mbar a (2.32 ... 72.5 psia) 30 bar a (435 psia) 5 bar a (72.5 psia) 30 bar a (435 psia) 1 ... 30 bar a (14.5 ... 435 psia) 100 bar a (1450 psia) 30 bar a (435 psia) 100 bar a (1450 psia) Lower measuring limit • Measuring cell with silicone oil filling 0 mbar a (0 psia) Upper measuring limit 100 % of max. span Output Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Load Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Protection against polarity reversal Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Measuring accuracy Acc. to IEC 60770-1 Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Span ratio r = max. span/set span Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - r 10 0.1 % 0.1 % - 10 < r 30 0.2 % 0.2 % (0.1 r) %/year (0.1 r) %/year • at -10 ... +60 °C (14 ... 140 °F) (0.1 r + 0.2) %1) (0.1 r + 0.2) %1) • at -40 ... -10 °C and 60 ... 85 °C (-40 ... +14 °F and 140 ... 185 °F) (0.1 r + 0.15) %/10 K (0.1 r + 0.15) %/10 K Measured Value Resolution - 3 10-5 of nominal measuring range Long-term stability (temperature change ± 30 °C (± 54 °F)) Influence of ambient temperature Siemens FI 01 · 2015 US Edition 1/119 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from gauge pressure series) SITRANS P DS III series for absolute pressure (from the gauge pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Rated conditions Degree of protection (to IEC 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) -20 ... +100 °C (-4 ... +212 °F) with 30 bar a measuring cell • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design 1.5 kg ( 3.3 lb) Weight (without options) Enclosure material Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Connection shank Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4610 Stainless steel, mat. no. 1.4404/316L • Oval flange • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819 Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection Connection shank G½B to EN 837-1, female thread ½ -14 NPT or oval flange (PN 160 (MAWP 2320 psia)) to DIN 19213 with mounting thread M10 or 7/16-20 UNF to IEC 61518 Material of mounting bracket • Steel Sheet-steel, Mat. No. 1.0330, chrome-plated Sheet stainless steel, mat. no. 1.4301 (SS 304) • Stainless steel Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Bus voltage Current consumption 1/120 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from gauge pressure series) SITRANS P DS III series for absolute pressure (from the gauge pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Marking - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature - Connection -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 To circuits with values: UH = 10.5 ... 45 V DC • Dust explosion protection for zone 20 PTB 01 ATEX 2055 - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 01 ATEX 2055 • Dust explosion protection for zone 21/22 - Marking - Connection Ex II 2 D IP65 T 120 °C To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connection (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 1) To circuits with values: UH = 9 ... 32 V DC L i = 7 H, Ci = 1.1 nF Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.08. r + 0.16) % / 28 °C (50 °F). Siemens FI 01 · 2015 US Edition 1/121 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from gauge pressure series) HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 to 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function 1/122 Siemens FI 01 · 2015 US Edition - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from gauge pressure series) Selection and Ordering data Article No. Selection and Ordering data Article No. Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with HART 7MF 4 2 3 3 - Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with HART 7MF 4 2 3 3 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Measuring span (min. ... max.) 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psia) 0.16 ... 5 bar a (2.32 ... 72.5 psia) 1 ... 30 bar a (14.5 ... 435 psia) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 1 3 Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting7) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"8) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"9) - "Ex nA/ic (Zone 2)"10) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"9)11) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)11) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"8) Electrical connection/cable entry • Screwed gland Pg 13.512) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector12) • M12 connectors (stainless steel) 13) 14) 0 1 6 7 Power supply units see Chap. 7 "Supplementary Components". D F G H Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version for diaphragm seal2) 3) 4) 5) 6) 77777 - 7777 1) For oxygen application, add Order code E10. 2) Version 7MF4233-1DY... only up to max. span 200 mbar a (80 inH2O a). 3) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF423.-..Y..-.... and 7MF4900-1...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Not in conjunction with Electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 8) Without cable gland, with blanking plug. 9) With enclosed cable gland Ex ia and blanking plug. A B C Y 0 1 2 3 4 5 6 0 3 10) Configurations 1 2 with HAN and M12 connectors are only available in Ex ic. 11) Only in connection with IP65. 12) Only in connection with Ex apporval A, B or E. 13) Only in connection with Ex apporval A, B, E or F. 14) M12 delivered without cable socket A B D P E R F S NC A B C D F Siemens FI 01 · 2015 US Edition 1/123 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from gauge pressure series) Selection and Ordering data Article No. Selection and Ordering data Pressure transmitters for absolute pressure from gauge pressure series SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 2 3 4 - SITRANS P DS III with PROFIBUS PA (PA) SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 2 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Nominal measuring range 250 mbar a (3.62 psia) 1300 mbar a (18.85 psia) 5 bar a (72.5 psia) 30 bar a (435 psia) 77777 - 7777 Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 - Mounting thread M12 to DIN 19213 • Male thread M20 x 1.5 • Male thread ½ -14 NPT Non-wetted parts materials • Housing made of die-cast aluminium • Housing stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"7) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"8) - "Ex nA/ic (Zone 2)" 9) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"8) 10) (not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)10) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"7) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel) 11) 12) 1/124 Siemens FI 01 · 2015 US Edition 7MF 4 2 3 4 7MF 4 2 3 5 77777 - 7777 Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 1 3 D F G H 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Version as diaphragm seal 2) 3) 4) 5) 6) Article No. Pressure transmitters for absolute pressure from gauge pressure series A B C Y 0 1 2 3 4 5 6 0 3 1 2 A B D P E R F S NC B C F 1) For oxygen application, add Order code E10. 2) Version 7MF4233-1DY... only up to max. span 200 mbar a (2.9 psia). 3) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF423.-..Y..-.... and 7MF4900-1...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Without cable gland, with blanking plug. 8) With enclosed cable gland Ex ia and blanking plug. 9) Configurations with HAN and M12 connectors are only available in Ex ic. 10) Only in connection with IP65. 11) Only in connection with Ex approval A, B, E or F. 12) M12 delivered without cable socket. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from gauge pressure series) Selection and Ordering data Order code Further designs Selection and Ordering data HART PA FF Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel E01 A01 A02 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“ and IP65) E10 Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) A30 A31 A32 A33 Oxygen application (In the case of oxygen measurement and inert liquid max. 100 bar (1450 psi) at 60°C (140 °F)) Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 A50 Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E254) "Flameproof" explosion protection according to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) E264) Cable sockets for M12 connectors (metal (CuZn)) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) B11 B12 B13 B14 B16 B21 Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E284) English rating plate Pressure units in inH20 and/or psi Quality inspection certificate (Five-step factory calibration) to IEC 60770-21) C11 Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E454) Inspection certificate2) Acc. to EN 10204-3.1 C12 Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E464) Factory certificate Acc. to EN 10204-2.2 C14 E554) Functional safety (SIL2) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) Explosion protection "Explosion-proof" to NEPSI (China) (only for transmitter 7MF4...-.....-.D..) E564) Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C213) E574) Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 Explosion-proof "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) E584) Device passport Russia C99 Ex protection „Ex ia“, „Ex d“ and „Zone 2“ to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) E704) Two coats of lacquer on casing and cover (PU on epoxy) G10 Transient protector 6 kV (lightning protection) J01 Oval flange NAM (ASTAVA) J06 (For price request please contact the technical support www.siemens.com/automation/supportrequest) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Supplied with oval flange (1 item), PTFE packing and screws in thread of oval flange D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 1) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3.1 is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H 4) Option does not include ATEX approval, but instead includes only the country-specific approval. Siemens FI 01 · 2015 US Edition 1/125 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from gauge pressure series) Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar a, bar a, kPaabs, MPaabs, psia2) Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 Setting of pressure indication in pressure units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Y21 Setting of pressure indication in non-pressure units3) Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Y22 + Y01 Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Factory mounting of valve manifolds, see accessories. Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available 1) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. 2) Only absolute pressure units selectable. Negative pressure values not permitted. 3) Preset values can only be changed over SIMATIC PDM. 1/126 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from gauge pressure series) 53 (2.1) 54 (2.13) 27 (1.1) Ø80 (3.15) 2 17 (0.67) 29 (1.14) 4) 5 84 (3.31) 6 3 4 3 7 9 72 (2.8) 8 120 (4.72) 68 (2.68) SW 36 approx. 40 (1.6) 171 (6.7) approx. 96 (3.78) 176 (6.93) 237 (9.33) 143 (5.6) 74 (2.9) 50 (1.97) 117 (4.61) 15 (0.6) 1 24 (0.94) ■ Dimensional drawings Space for rotation of housing min. 90 (3.54) 5) 123 (4.84) Ø50 ... 60 (1.97 ... 2.36) 105 (4.13) Electronic side, digital display (longer overall length for cover with window)1) 5 Protective cover over keys 6 Blanking plug 2 Terminal side1) 7 3 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/Han 8D2) 3) plug Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Process connection: Connection shank G½B or Oval flange 9 Mounting bracket (option) 1 4 Harting adapter 1) 2) 3) 4) 5) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) Minimum distance for rotating SITRANS P DS III pressure transmitters for absolute pressure, from the pressure series, dimensions in mm (inch) Siemens FI 01 · 2015 US Edition 1/127 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from differential pressure series) ■ Technical specifications SITRANS P, DS III for absolute pressure (from the differential pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure Absolute pressure Span (min. ... max.) Maximum operating pressure Nominal measuring range Maximum operating pressure 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 32 bar a (464 psia) 250 mbar a (3.62 psia) 32 bar a (464 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psia) 32 bar a (464 psia) 1300 bar a (18.85 psia) 32 bar a (464 psia) 160 ... 5000 mbar a (2.32 ... 72.52 psia) 32 bar a (464 psia) 5 bar a (72.5 psia) 32 bar a (464 psia) 1 ... 30 bar a (14.5 ... 435 psia) 160 bar a (2320 psia) 30 bar a (435 psia) 160 bar a (2320 psia) 5.3 ... 100 bar a (76.9 ... 1450 psia) 160 bar a 100 bar a (2320 psia) (1450 psia) (for connection thread M10 and 7/16-20 UNF in the process flanges) 160 bar a (2320 psia) (for connection thread M10 and 7/16-20 UNF in the process flanges) Lower measuring limit • Measuring cell with silicone oil filling 0 mbar a (0 psia) 100 % of max. span Upper measuring limit Output Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA - • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Load Electrical damping (step width 0.1 s) Set to 2 s (0 ... 100 s) Acc. to IEC 60770-1 Measuring accuracy Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Reference conditions (All error data refer always refer to the set span) Span ratio r = max. span/set span Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - r 10 0.1 % 0.1 % - 10 < r 30 0.2 % 0.2 % (0.1 r) %/year (0.1 r) %/year • at -10 ... +60 °C (14 ... 140 °F) (0.1 r + 0.2) %1) (0.1 r + 0.2) %1) • at -40 ... -10 °C and 60 ... 85 °C (-40 ... +14 °F and 140 ... 185 °F) (0.1 r + 0.15) %/10 K (0.1 r + 0.15) %/10 K Measured Value Resolution - 3 10-5 of nominal measuring range Long-term stability (temperature change ± 30 °C (± 54 °F)) Influence of ambient temperature 1/128 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from differential pressure series) SITRANS P, DS III for absolute pressure (from the differential pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Rated conditions Degree of protection (to IEC 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design 4.5 kg ( 9.9 (lb) Weight (without options) Enclosure material Low-copper die-cast aluminum, GD-AlSi12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819, Monel, mat. no. 2.4360, tantalum or gold • Process flanges and sealing screw Stainless steel, mat. no. 1.4408, Hastelloy C4, mat. no. 2.4610 or Monel, mat. no. 2.4360 • O-Ring FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxigen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to IEC 61518 Material of mounting bracket • Steel Sheet-steel, Mat. No. 1.0330, chrome-plated Sheet stainless steel, mat. no. 1.4301 (SS 304) • Stainless steel Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Bus voltage Current consumption Siemens FI 01 · 2015 US Edition 1/129 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from differential pressure series) SITRANS P, DS III for absolute pressure (from the differential pressure series) HART PROFIBUS PA and FOUNDATION Fieldbus Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Marking - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature - Connection -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 To circuits with values: UH = 10.5 ... 45 V DC • Dust explosion protection for zone 20 PTB 01 ATEX 2055 - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 01 ATEX 2055 • Dust explosion protection for zone 21/22 - Marking Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connection (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 1) To circuits with values: UH = 9 ... 32 V DC L i = 7 H, Ci = 1.1 nF Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.08. r + 0.16) % / 28 °C (50 °F). 1/130 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from differential pressure series) HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 to 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens FI 01 · 2015 US Edition 1/131 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from differential pressure series) Selection and Ordering data Article No. Selection and Ordering data Article No. Pressure transmitters for absolute pressure from differential pressure series, SITRANS P DS III with HART 7MF 4 3 3 3 - Pressure transmitters for absolute pressure from differential pressure series, SITRANS P DS III with HART 7MF 4 3 3 3 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Measuring span (min. ... max.) 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psia) 0.16 ... 5 bar a (2.32 ... 72.5 psia) 1 ... 30 bar a (14.5 ... 435 psia) 5.3 ... 100 bar a (76.9 ... 1450 psia) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 1 3 Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Vent on side of process flange 7) - Mounting thread 7/16-20 UNF to EN 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) Die-cast aluminum Stainless steel precision casting8) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"9) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)" 10) - "Ex nA/ic (Zone 2)"11) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"10)12) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)12) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)" 9) Electrical connection/cable entry • Screwed gland Pg 13.513) • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector13) • M12 connectors (stainless steel) 14) 15) 1/132 Siemens FI 01 · 2015 US Edition 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) A B C E H L Y 2 0 6 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel 0 1 Power supply units see Chap. 7 "Supplementary Components". D F G H KE Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum Tantalum Monel Monel Gold Gold Version for diaphragm seal2) 3) 4) 5) 6) 77777 - 7777 2 3 1 2 A B D P E R F S NC A B C D F 1) For oxygen applications, add Order code E10. 2) Version 7MF4333-1DY... only up to max. span 200 mbar a (2.9 psia). 3) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF433.-..Y..-.... und 7MF4900-1...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Not for span "5.3 ... 100 bar a (76.9 ... 1450 psia)". Position of the top vent valve in the process flange (see dimensional drawing). 8) Not in conjunction with Electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 9) Without cable gland, with blanking plug 10) With enclosed cable gland Ex ia and blanking plug 11) Configurations with HAN and M12 connectors are only available in Ex ic. 12) Only in connection with IP65. 13) Only in connection with Ex approval A, B or E. 14) Only in connection with Ex approval A, B, E or F. 15) M12 delivered without cable socket. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from differential pressure series) Selection and Ordering data Article No. Selection and Ordering data Pressure transmitter for absolute pressure from differential pressure series Pressure transmitter for absolute pressure from differential pressure series SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 3 3 4 - SITRANS P DS III with PROFIBUS PA (PA) SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 3 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Nominal measuring range 250 mbar a (3.62 psia) 1300 mbar a (18.85 psia) 5 bar a (72.5 psia) 30 bar a (435 psia) 100 bar a (1450 psia) 77777 - 7777 Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Vent on side of process flange 7) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) 1 3 D F G H KE Die-cast aluminum Stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"8) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)" 9) - "Ex nA/ic (Zone 2)"10) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"9) 11) (not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)11) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)" 8) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)12)13) 7MF 4 3 3 5 77777 - 7777 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) A B C E H L Y 2 0 6 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel 7MF 4 3 3 4 - Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum Tantalum Monel Monel Gold Gold Version as diaphragm seal 2) 3) 4) 5) 6) Article No. 1) For oxygen application, add Order code E10. 2) Version 7MF4334-1DY... only up to max. span 200 mbar a (80 inH2O a). 3) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 4) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 5) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF433.-..Y..-.... und 7MF4900-1...-.B 6) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 7) Not for nominal measuring range 100 bar a (1450 psia). Position of the top vent valve in the process flange (see dimensional drawing). 8) Without cable gland, with blanking plug 9) With enclosed cable gland Ex ia and blanking plug 10) Configurations with HAN and M12 connectors are only available in Ex ic. 11) Only in connection with IP65. 12) Only in connection with Ex approval A, B, E or F. 13) M12 delivered without cable socket 2 3 1 2 A B D P E R F S NC B C F Siemens FI 01 · 2015 US Edition 1/133 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for absolute pressure (from differential pressure series) Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F)) • NBR (Buna N) Selection and Ordering data HART PA FF A01 A02 A20 A21 A22 A23 A30 A31 A32 A33 Sealing screw A40 ¼-18 NPT, with valve in mat. of process flanges Cable sockets for M12 connectors (metal (CuZn)) Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) A50 Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF E01 Oxygen application E10 (In the case of oxygen measurement and inert liquid max. 100 bar (1450 psi) at 60°C (140 °F)) Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 Dual seal E24 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“ and IP65) Explosion-proof "Intrinsic safety" (Ex ia) to E254) INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) "Flameproof" explosion protection accord- E264) ing to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E284) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E454) Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E464) Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E554) B11 B12 B13 B14 B16 English rating plate Pressure units in inH20 and/or psi B21 Explosion protection "Explosion-proof" to E564) NEPSI (China) (only for transmitter 7MF4...-.....-.D..) C11 Explosion-proof "Zone 2" to NEPSI (China) E574) (only for transmitter 7MF4...-.....-.E..) Quality inspection certificate (Five-step factory calibration) to IEC 60770-21) Inspection certificate2) Acc. to EN 10204-3.1 Ex protection „Ex ia“, „Ex d“ and „Zone 2“ E584) to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) C12 Factory certificate Acc. to EN 10204-2.2 C14 E704) Functional safety (SIL2) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) Two coats of lacquer on casing and cover (PU on epoxy) G10 Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C213) Interchanging of process connection side H01 Vent on side for gas measurements H02 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K01, K02 and K04)5) Transient protector 6 kV (lightning protec- J01 tion) Chambered graphite gasket for process flange J02 Chambered PTFE graphite gasket J03 EPDM O-rings for process flange with approval (WRC/WRAS) J05 Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)6) J08 Vent valve or blanking plug of process J09 flange welded-in (orientation: on left when 6) viewing the display) Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 Device passport Russia C99 Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) (only together with seal diaphragm made of Hastelloy and stainless steel) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Supplied with oval flange (1 item), PTFE packing and screws in thread of process flange D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 (For price request please contact the technical support www.siemens.com/automation/support-request) 1/134 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from differential pressure series) Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Process flange • Hastelloy K01 • Monel K02 • Stainless steel with PVDF insert K04 max. PN 10 (MAWP 145 psi), max. temperature of medium 90 °C (194 °F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible 1) 2) Selection and Ordering data HART PA FF Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H 4) Option does not include ATEX approval, but instead includes only the country-specific approval. 5) Not suitable for connection of remote seals. 6) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar a, bar a, kPaabs, MPaabs, psia2) Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indication in Y22 + non-pressure units3) Y01 Specify in plain text: 3 Y22: ..... up to ..... l/min, m /h, m, USgpm, ... (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Factory mounting of valve manifolds, see accessories. Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available 1) 2) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Only absolute pressure units selectable. Negative pressure values not permitted. 3) Preset values can only be changed over SIMATIC PDM. Siemens FI 01 · 2015 US Edition 1/135 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for absolute pressure (from differential pressure series) ■ Dimensional drawings 143 (5.6) 1 5 2 29 (1.14) 4) 84 (3.31) 6 3 7 8 166 (6.54) 53 (2.1) 24 (0.94) 69 (2.7) 50 (1.97) 128 (5.04) 15 (0.6) Ø80 (3.15) 12 10 11 52 (2.05) 3 17 (0.67) 4 72 (2.83) 68 (2.7) 105 (4.1) Electronic side, digital display (longer overall length for cover with window)1) 2 Terminal side1) 3 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/ Han 8D2) 3) plug 120 (4.7) 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Lateral venting for liquid measurement (Standard) 9 Lateral venting for gas measurement (suffix H02) 10 Mounting bracket (option) Harting adapter 11 Sealing screw with valve (option) 5 Protective cover over keys 12 Process connection: ¼-18 NPT (IEC 61518) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) 92 mm (3.62 inch) for minimum distance to permit rotation with indicator 4 2) 3) 4) 5) SITRANS P DS III pressure transmitters for absolute pressure, from the differential pressure series, dimensions in mm (inch) 1/136 Siemens FI 01 · 2015 US Edition 96 (3.8) Space for rotation of housing 9 approx. 96 (3.78) 1 262 (10.3) min. 90 (3.54) 5) 134 (5.28) 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow ■ Technical specifications SITRANS P, DS III for differential pressure and flow HART PROFIBUS PA and FOUNDATION Fieldbus Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure Differential pressure and flow Span (min. ... max.) Maximum operating pressure Nominal measuring range Maximum operating pressure 1 ... 20 mbar (0.4 ... 8 inH2O) 32 bar (464 psi) 20 mbar (8 inH2O) 32 bar (464 psi) 1 ... 60 mbar (0.4 ... 24 inH2O) 160 bar (2320 psi) 60 mbar (24 inH2O) 160 bar (2320 psi) 2.5 ... 250 mbar (1 ... 100 inH2O) 250 mbar (100 inH2O) 6 ... 600 mbar (2.4 ... 240 inH2O) 600 mbar (240 inH2O) 16 ... 1600 mbar (6.4 ... 642 inH2O) 1600 mbar (642 inH2O) 50 ... 5000 mbar (20 ... 2000 inH2O) 5 bar (2000 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 2.5 ... 250 mbar (1 ... 100 inH2O) 6 ... 600 mbar (2.4 ... 240 inH2O) 30 bar (435 psi) 420 bar (6091 psi) 250 mbar (100 inH2O) 600 mbar (240 inH2O) 16 ... 1600 mbar (6.4 ... 642 inH2O) 1600 mbar (642 inH2O) 50 ... 5000 mbar (20 ... 2000 inH2O) 5 bar (2000 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 30 bar (435 psi) 420 bar (6091 psi) Lower measuring limit • Measuring cell with silicone oil filling -100 % of max. span or 30 mbar a (0.44 psia) (-33 % with 30 bar (435 psi) measuring cell) Upper measuring limit 100 % of max. span (for oxygen version and inert filling liquid; max. 120 bar (1740 psi)) Output Output signal 4 ... 20 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal • Lower limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA - • Upper limit (infinitely adjustable) 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Load • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V - • With HART RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Set to 2 s (0 ... 100 s) Electrical damping (step width 0.1 s) Acc. to IEC 60770-1 Measuring accuracy Reference conditions (All error data refer always refer to the set span) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Span ratio r = max. span/set span Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - r 10 (0.0029 r + 0.071) % (0.0029 r + 0.071) % - 10 < r 30 (0.0045 r + 0.071) % (0.0045 r + 0.071) % - 30 < r 100 (0.005 r + 0.05) % (0.005 r + 0.05) % - r 10 0.1 % 0.1 % - 10 < r 30 0.2 % 0.2 % - r 10 0.2 % 0.2 % - 10 < r 30 0.4 % 0.4 % • Square-rooted characteristic (flow > 50 %) • Square-rooted characteristic (flow > 25 ... 50 %) Siemens FI 01 · 2015 US Edition 1/137 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow SITRANS P, DS III for differential pressure and flow HART PROFIBUS PA and FOUNDATION Fieldbus Long-term stability (temperature change ± 30 °C (± 54 °F)) • 250, 600, 1600 and 5000 mbar (0.29, 0.87, (0.125 r) per 5 years 2.32 and 7.25 psi)-measuring cell (0.125 r) per 5 years • 20 mbar (8 inH2O)-measuring cell (0.2 r) per year (0.2 r) per year • 60 mbar (24 inH2O)-measuring cell (0.25 r) % per 5 years (0.25 r) % per 5 years • 30 bar (435 psi)-measuring cell (0.25 r) % per 5 years (0.25 r) % per 5 years • at -10 ... +60 °C (14 ... 140 °F) (0.08 r + 0.1) %1) (0.08 r + 0.1) %1) • at -40 ... -10 °C and 60 ... 85 °C (-40 ... +14 °F and 140 ... 185 °F) (0.1 r + 0.15) %/10 K (0.1 r + 0.15) %/10 K (0.15 r) % per 70 bar (1015 psi) (0.15 r) % per 70 bar (1015 psi) (0.15 r) % per 32 bar (464 psi) (0.15 r) % per 32 bar (464 psi) 0.14 % per 70 bar (1015 psi) 0.14 % per 70 bar (1015 psi) 0.2 % per 32 bar (464 psi) 0.2 % per 32 bar (464 psi) - 3 10-5 of nominal measuring range Influence of ambient temperature (Twice the value with 20 mbar (8 inH2O)measuring cell Influence of static pressure • on the zero point (PKN) - 20 mbar (0.29 psi)-measuring cell • on the span (PKS) - 20 mbar (0.29 psi)-measuring cell Measured Value Resolution Rated conditions Degree of protection (to EN 60529) IP66 (optional IP66/IP68), NEMA 4X Temperature of medium • Measuring cell with silicone oil filling -40 ... +100 °C (-40 ... +212 °F) -20 ... +100 °C (-4 ... +212 °F) with 30 bar measuring cell • Measuring cell with inert filling liquid -20 ... +100 °C (-4 ... +212 °F) • In conjunction with dust explosion protection -20 ... +60 °C (-4 ... +140 °F) Ambient conditions • Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) - Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 % Condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design Weight (without options) Enclosure material Die-cast aluminum: 4.5 kg ( 9.9 lb) Stainless steel precision casting: 7.1 kg ( 15.6 lb) Low-copper die-cast aluminum, GD-AlSi12 or stainless steel precision casting, mat. no. 1.4408 Wetted parts materials • Seal diaphragm Stainless steel, mat. no. 1.4404/316L or Hastelloy C276, mat. no. 2.4819, Monel, mat. no. 2.4360, tantalum or gold Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxygen measurement pressure 100 bar (1450 psi) at 60 °C (140 °F)) Process connection Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/ -20 UNF to IEC 61518 16 Material of mounting bracket • Steel Sheet-steel, Mat. No. 1.0330, chrome-plated • Stainless steel 1/138 Siemens FI 01 · 2015 US Edition Sheet stainless steel, mat. no. 1.4301 (SS 304) © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow SITRANS P, DS III for differential pressure and flow HART PROFIBUS PA and FOUNDATION Fieldbus Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Bus voltage Current consumption • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Certificates and approvals Classification according to PED 97/23/EC PN 32/160 (MAWP 464/2320 psi) PN 420 (MAWP 6092 psi) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord. Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X - Marking Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature - Connection -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 To certified intrinsically-safe circuits with peak val- FISCO supply unit: ues: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W L i = 7 H, Ci = 1.1 nF - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Permissible ambient temperature - Connection To circuits with values: UH = 10.5 ... 45 V DC - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature - Connection 120 °C (248 °F) To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 - Marking - Connection FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1 W L i = 7 H, Ci = 1.1 nF - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Dust explosion protection for zone 21/22 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 • Dust explosion protection for zone 20 PTB 01 ATEX 2055 Ex II 2 D IP65 T 120 °C To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W Siemens FI 01 · 2015 US Edition 1/139 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow SITRANS P, DS III for differential pressure and flow HART • Type of protection "n" (zone 2) Ex II 2/3 G Ex nA IIC T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connection (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) • Explosion protection to CSA - Identification (XP/DIP) or (IS) 1) PROFIBUS PA and FOUNDATION Fieldbus PTB 13 ATEX 2007 X L i = 7 H, Ci = 1.1 nF Certificate of Compliance 3008490 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.064 . r + 0.08) % / 28 °C (50 °F). 1/140 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for PC SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customerspecific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output • Analog input - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens FI 01 · 2015 US Edition 1/141 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 32/160 (MAWP 464/2320 psi) 7MF 4 4 3 3 - SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 32/160 (MAWP 464/2320 psi) 7MF 4 4 3 3 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid1) grease-free to cleanliness level 2 Electrical connection/cable entry • Screwed gland Pg 13.513) • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector13)14) • M12 connectors (stainless steel)15)16) 1 3 Measuring span (min. ... max.) PN 32 (MAWP 464 psi) 1 ... 20 mbar2) (0.4015 ... 8.03 inH2O) B PN 160 (MAWP 2320 psi) 1 ... 60 mbar (0.4015 ... 24.09 inH2O) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) C D E F G H Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Vent on side of process flange 2) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) Die-cast aluminum Stainless steel precision casting8) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"9) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"10) - "Ex nA/ic (Zone 2)"11) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"10)12) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)12) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"9) 1/142 Siemens FI 01 · 2015 US Edition F 0 1 6 7 Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) A B C E H L Y 2 0 6 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel A B C D Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum3) Tantalum Monel3) Monel Gold3) Gold Version for diaphragm seal4) 5) 6) 7) 77777 - 7777 1) For oxygen application, add Order code E10. 2) Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). 3) Not in conjunction with max. span 20 and 60 mbar (8.03 und 24.09 inH2O)) 4) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF443.-..Y..-.... und 7MF4900-1...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Not in conjunction with Electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 9) Without cable gland, with blanking plug 10) With enclosed cable gland Ex ia and blanking plug 11) Configurations 2 3 in connection with IP65. 13) Only in connection with Ex approval A, B or E. 14) Permissible 1 2 A B D P E R F S NC with HAN and M12 connectors are only available in Ex ic. 12) Only only for crimp-contact of conductor cross-section 1 mm2 15) Only in connection with Ex approval A, B, E or F. 16) M12 delivered without cable socket. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow Selection and Ordering data Article No. Selection and Ordering data Pressure transmitters for differential pressure and flow PN 32/160 (MAWP 464/2320 psi) SITRANS P DS III with PROFIBUS PA (PA) SITRANS P DS III with FOUNDATION Fieldbus (FF) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Inert liquid1) Measuring cell cleaning normal grease-free to cleanliness level 2 Pressure transmitters for differential pressure and flow PN 32/160 (MAWP 464/2320 psi) 7MF 4 4 3 4 - SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 4 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 77777 - 7777 1 3 B PN 160 (MAWP 2320 psi) 60 mbar (24.09 inH2O) 250 mbar (100.4 inH2O) 600 mbar (240.9 inH2O) 1600 mbar (642.4 inH2O) 5 bar (2008 inH2O) 30 bar (435 psi) C D E F G H - Mounting thread M10 to DIN 19213 (only for replacement requirement) 7MF 4 4 3 5 77777 - 7777 Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) B C F 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges2) - Mounting thread 7/16-20 UNF to IEC 61518 7MF 4 4 3 4 - Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)12) 13) Nominal measuring range PN 32 (MAWP 464 psi) 20 mbar 2) (8.03 inH2O) Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy Tantalum 3) Tantalum Monel3) Monel Gold 3) Gold Version as diaphragm seal 4) 5) 6) 7) Article No. A B C E H L Y 2 0 6 4 1) For oxygen application, add Order code E10. 2) Not suitable for connection of remote seal. Position of the top vent valve in the process flange (see dimensional drawing). 3) Not in conjunction with max. span 20 and 60 mbar (8.03 und 24.09 inH2O)) 4) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF443.-..Y..-.... und 7MF4900-1...-.B 7) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 8) Without cable gland, with blanking plug. 9) With enclosed cable gland Ex ia and blanking plug. 10) Configurations with HAN and M12 connectors are only available in Ex ic. 11) Only in connection with IP65. 12) Only in connection with Ex approval A, B, E or F. 13) M12 delivered without cable socket Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"8) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"9) - "Ex nA/ic (Zone 2)" 10) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"9) 11)(not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)11) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"8) 2 3 1 2 A B D P E R F S NC Siemens FI 01 · 2015 US Edition 1/143 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Selection and Ordering data HART PA A01 A02 FF A20 A21 A22 A23 A30 A31 A32 A33 Sealing screws (2 units) ¼-18 NPT, with valve in mat. of process flanges A40 Cable sockets for M12 connectors (metal (CuZn)) A50 B11 B12 B13 B14 B16 English rating plate Pressure units in inH2O and/or psi B21 Quality inspection certificate (Five-step factory calibration) to IEC 60770-21) C11 Inspection certificate2) to EN 10204-3.1 C12 Factory certificate to EN 10204-2.2 C14 Functional safety (SIL2) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C213) Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 Device passport Russia (For price request please contact the technical support www.siemens.com/automation/supportrequest) C99 plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) 1/144 Siemens FI 01 · 2015 US Edition Order code Further designs Add "-Z" to Article No. and specify Order code. HART PA FF Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) (only together with seal diaphragm made of Hastelloy and stainless steel) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Process flange screws made of Monel (max. nominal pressure PN20) D34 Supplied with oval flange set (2 items), PTFE packings and screws in thread of process flanges D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“and IP65) E01 Overfilling safety device for flammable and non-flammable liquids (max. PN 32 (MAWP 464 psi), basic device with type of protection "Intrinsic safety (Ex ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") E08 Oxygen application (In the case of oxygen measurement and inert liquid max. 100 bar (1450 psi) at 60°C (140 °F)) E10 Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) E254) "Flameproof" explosion protection according to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) E264) Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E284) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E454) Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E464) Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E554) Explosion protection "Explosion-proof" to NEPSI (China) (only for transmitter 7MF4...-.....-.D..) E564) Explosion-proof "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) E574) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) E584) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E704) © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Selection and Ordering data HART PA FF Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text: • in the case of linear characteristic curve (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi • in the case of square rooted characteristic (max. 5 characters): Y02: ... up to ... mbar, bar, kPa, MPa, psi Two coats of lacquer on casing and cover (PU on epoxy) G10 Interchanging of process connection side H01 Vent on side for gas measurements H02 Stainless steel process flanges for vertical differential pressure lines (not together with K01, K02 and K04)5) H03 Transient protector 6 kV (lightning protection) J01 Chambered graphite gasket for process flange J02 Chambered PTFE graphite gasket J03 EPDM O-rings for process flange with approval (WRC/WRAS) J05 Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)6) J08 Vent valve or blanking plug of process flange welded-in (orientation: on left when viewing the display)6) J09 K01 K02 K04 Process flange • Hastelloy • Monel • Stainless steel with PVDF insert max. PN 10 (MAWP 145 psi), max. temperature of medium 90 °C (194 °F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible Factory mounting of valve manifolds, see accessories. Supplementary electronics for 4-wire connection, see accessories. = available 1) 2) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. Order code HART PA FF 1) Y01 Y02 Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 char., specify in plain text: Y16: ....... Y16 Entry of HART address (TAG) Max. 8 char., specify in plain text: Y17: ....... Y17 Setting of pressure indicator in pressure units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Y21 Setting of pressure indicator in nonpressure units2) Specify in plain text: Y22: ..... up to ..... l/min, m3/h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Y223) + Y01 or Y02 Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Factory mounting of valve manifolds, see accessories. Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 und D05 can be factory preset 3) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H = available 4) Option does not include ATEX approval, but instead includes only the countryspecific approval. 1) 5) Not suitable for connection of remote seal. 6) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. 2) Preset values can only be changed over SIMATIC PDM. 3) Not in conjunction with over-filling safety device for flammable and nonflammable liquids (Order code "E08") Siemens FI 01 · 2015 US Edition 1/145 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) 7MF 4 5 3 3 - SITRANS P DS III with HART pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) 7MF 4 5 3 3 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Measuring span (min. ... max.) 2.5 ... 250 mbar (1.004 ... 100.4 inH2O) 6 ... 600 mbar (2.409 ... 240.9 inH2O) 16 ... 1600 mbar (6.424 ... 642.4 inH2O) 50 ... 5000 mbar (20.08 ... 2008 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting: mA) • with customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 1 D E F G H Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) Die-cast aluminum Stainless steel precision casting6) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"7) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"8) - "Ex nA/ic (Zone 2)"9) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"8)10) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)10) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)" 7), max PN 360 Electrical connection/cable entry • Screwed gland Pg 13.511) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector11)12) • M12 connectors (stainless steel)13) 14) 1/146 Siemens FI 01 · 2015 US Edition 6 7 Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) A B L Y 3 1 7 5 1) Not in conjunction with max. span 600 mbar (240.9 inH2O) 2) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF453.-..Y..-.... und 7MF4900-1....-.B 5) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 6) Not in conjunction with Electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 7) Without cable gland, with blanking plug 8) With enclosed cable gland Ex ia and blanking plug 9) Configurations with HAN and M12 connectors are only available in Ex ic. 10) Only in connection with IP65. 11) Only in connection with Ex approval A, B or E. 12) Permissible Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel 0 1 Power supply units see Chap. 7 "Supplementary Components". Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Gold1) Gold Ausführung als Membrandruckmittler 2) 3) 4) 5) 77777 - 7777 2 3 1 2 A B D P E R F S NC A B C D F only for crimp-contact of conductor cross-section 1 mm2 13) Only in connection with Ex approval A, B, E or F. 14) M12 delivered without cable socket. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow Selection and Ordering data Article No. Selection and Ordering data Pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) Article No. Pressure transmitters for differential pressure and flow, PN 420 (MAWP 6092 psi) SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 5 3 4 - SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 5 3 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 5 3 5 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 5 3 5 - Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Nominal measuring range 250 mbar (100.4 inH2O) 600 mbar (240.9 inH2O) 1600 mbar (642.4 inH2O) 5 bar (2008 inH2O) 30 bar (435 psi) 1 7777 - 7777 D E F G H Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) • Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing). - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M12 to DIN 19213 (only for replacement requirement) A B L Y 3 1 7 5 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"6) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"7) - "Ex nA/ic (Zone 2)" 8) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"7) 9) (not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)9) • With FM + CSA, Type of protection: - "Intrinsic safety and explosion-proof (is + xp)"6), max PN 360 Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel) 10) 11) 0 1 6 7 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Gold 1) Gold Ausführung als Membrandruckmittler 2) 3) 4) 5) 1 7777 - 7777 Display • Without (display hidden) • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) 2 3 1) Not in conjunction with max. span 600 mbar (240.9 inH2O) 2) When the manufacture’s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3.1.is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included wiht the tranmitter order number, for example 7MF453.-..Y..-.... und 7MF4900-1....-.B 5) The standard measuring cell filling for configurations with remote seals (Y) is silicone oil. 6) Without cable gland, with blanking plug. 7) With enclosed cable gland Ex ia and blanking plug. 8) Configurations with HAN and M12 connectors are only available in Ex ic. 9) Only in connection with IP65. 10) Only in connection with Ex approval A, B, E or F. 11) M12 delivered without cable socket 1 2 A B D P E R F S NC B C F Siemens FI 01 · 2015 US Edition 1/147 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for differential pressure and flow Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. Pressure transmitter with mounting bracket (1x fixing angle, 2 x nut, 2 x Uwasher or 1 x bracket, 2 x nut, 2 x Uwasher) made of: • Steel • Stainless steel O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Selection and Ordering data HART PA A01 A02 FF A20 A21 A22 A23 A30 A31 A32 A33 Sealing screws (2 units) A40 ¼-18 NPT, with valve in mat. of process flanges Cable sockets for M12 connection (metal (CuZn)) Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) A50 B11 B12 B13 B14 B16 English rating plate Pressure units in inH2O and/or psi B21 Quality inspection certificate (Five-step factory calibration) to IEC 60770-2 C11 Inspection certificate Acc. to EN 10204-3.1 C12 Factory certificate Acc. to EN 10204-2.2 C14 Functional safety (SIL2) C20 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C211) Functional safety (SIL2/3) C23 Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration Device passport Russia (For price request please contact the technical support www.siemens.com/automation/supportrequest) C99 Setting of upper limit of output signal to 22.0 mA D05 Manufacturer's declaration acc. to NACE (MR 0103-2012 and MR 0175-2009) (only together with seal diaphragm made of Hastelloy and stainless steel) D07 Degree of protection IP66/IP68 (only for M20 x 1.5 and ½-14 NPT) D12 Nom. press. rating PN 500 (MAWP 7250 psi) D56 (Only for measuring cell 600 mbar ... 30 bar (240 inH2O ... 435 psi), SIL- und Ex-options not possible))2) Capri cable gland 4F CrNi and clamping device (848699 + 810634) included 1/148 Siemens FI 01 · 2015 US Edition HART PA FF Use in or on zone 1D/2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“and IP65) E01 Export approval Korea E11 Dual seal E24 Explosion-proof "Intrinsic safety" (Ex ia) to E253) INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) "Flameproof" explosion protection accord- E263) ing to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E283) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E453) Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E463) Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) E553) Ex prot. "Explosion-proof" to NEPSI (China) E563) (only for transmitter 7MF4...-.....-.D..) Explosion-proof "Zone 2" to NEPSI (China) E573) (only for transmitter 7MF4...-.....-.E..) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ E583) to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E703) Two coats of lacquer on casing and cover (PU on epoxy) G10 Interchanging of process connection side H01 Stainless steel process flanges for vertical H03 differential pressure lines Transient protector 6 kV (lightning protec- J01 tion) Chambered graphite gasket for process flange J02 EPDM O-rings for process flange with approval (WRC/WRAS) J05 Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)4) J08 Vent valve or blanking plug of process J09 flange welded-in (orientation: on left when 4) viewing the display) 1) D59 Order code Further designs Add "-Z" to Article No. and specify Order code. Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H Tested according to IEC 61010. Only for measuring materials of the group of fluids 2 in accordance with PED permissible. Not for use with dangerous media suitable. 3) Option does not include ATEX approval, but instead includes only the country-specific approval. 4) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. 2) © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text: • in the case of linear characteristic curve (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi • in the case of square rooted characteristic (max. 5 characters): Y02: ... up to ... mbar, bar, kPa, MPa, psi 1) Y01 Y02 Y15 Measuring point text (entry in device vari- Y16 able) Max. 27 char., specify in plain text: Y16: ....... Entry of HART address (TAG) Y17 Max. 8 char., specify in plain text: Y17: ......... Setting of pressure indication in pressure Y21 units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indication in Y22 + non-pressure units2) Y01 or Y02 Specify in plain text: 3 Y22: ..... up to ..... l/min, m /h, m, USgpm, ... (specification of measuring range in pressure units "Y01" or "Y02" is essential, unit with max. 5 characters) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Preset bus address possible between 1 and 126 Specify in plain text: Y25: ..................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Factory mounting of valve manifolds, see accessories. Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset. = available 1) 2) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Preset values can only be changed over SIMATIC PDM. Siemens FI 01 · 2015 US Edition 1/149 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for differential pressure and flow ■ Dimensional drawings 143 (5.6) 1 5 2 29 (1.14) 4) 84 (3.31) 6 3 7 8 166 (6.54) 53 (2.1) 24 (0.94) 69 (2.7) 50 (1.97) 128 (5.04) 15 (0.6) Ø80 (3.15) 12 10 11 52 (2.05) 3 17 (0.67) 4 72 (2.83) 68 (2.7) 105 (4.1) Electronic side, digital display (longer overall length for cover with window)1) 2 Terminal side1) 3 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/ Han 8D2) 3) plug 120 (4.7) 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Lateral venting for liquid measurement (Standard) 9 Lateral venting for gas measurement (suffix H02) 10 Mounting bracket (option) Harting adapter 11 Sealing screw with valve (option) 5 Protective cover over keys 12 Process connection: ¼-18 NPT (IEC 61518) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" For Pg 13,5 with adapter approx. 45 mm (1.77 inch) 92 mm (3.62 inch) for minimum distance to permit rotation with indicator 4 2) 3) 4) 5) SITRANS P DS III pressure transmitters for differential pressure and flow, dimensions in mm (inch) 1/150 Siemens FI 01 · 2015 US Edition 96 (3.8) Space for rotation of housing 9 approx. 96 (3.78) 1 262 (10.3) min. 90 (3.54) 5) 134 (5.28) 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 143 (5.6) 53 (2.1) 17 (0.67) 29 (1.14) 8) 5 84 (3.31) Ø80 (3.15) 50 (1.97) 1 approx. 96 (3.78) 6 3 4 3 7 2 min. 90 (3.54) 4) approx. 85 (3.35) 6) Space for rotation of housing 8 8 128 (5.04) approx. 217 (8.54) 7) 15 (0.6) 24 (0.94) SITRANS P DS III for differential pressure and flow 9 60 (2.36) 5) approx. 87 (3.43) 65 (2.56) Electronic side, digital display (longer overall length for cover with window)1) 5 Protective cover over keys 6 Blanking plug 2 Terminal side1) 7 3 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/ Han 8D2) 3) plug Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Sealing screw with valve (option) 9 Process connection: ¼-18 NPT (IEC 61518) 1 4 Harting adapter 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" 92 mm (3.6 inch) for minimum distance to permit rotation with indicator 74 mm (2.9 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) 91 mm (3.6 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) 219 mm (8.62 inch) for PN ≥ 420 (MAWP ≥ 6092 psi) For Pg 13,5 with adapter approx. 45 mm (1.77 inch) 2) 3) 4) 5) 6) 7) 8) SITRANS P DS III pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines, optional "H03" , dimensional drawing, dimensions in mm (inch) SITRANS P DS III pressure transmitters for differential pressure and flow, with process covers for vertical differential pressure lines Siemens FI 01 · 2015 US Edition 1/151 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for level ■ Technical specifications SITRANS P DS III for level HART PROFIBUS PA or FOUNDATION Fieldbus Input Measured variable Level Spans (infinitely adjustable) or nominal measuring Span (min. ... max.) range and max. permissible operating pressure Maximum operating pressure Nominal measuring range Maximum operating pressure 25 ... 250 mbar (10 ... 100 inH2O) See "Mounting flange" 250 mbar (100 inH2O) See "Mounting flange" 25 ... 600 mbar (10 ... 240 inH2O) See "Mounting flange" 600 mbar (240 inH2O) See "Mounting flange" 53 ... 1600 mbar (21 ... 642 inH2O) See "Mounting flange" 1600 mbar (642 inH2O) See "Mounting flange" 160 ... 5000 mbar (64 ... 2000 inH2O) See "Mounting flange" 5 bar (2000 inH2O) See "Mounting flange" Lower measuring limit • Measuring cell with silicone oil filling -100 % of max. span or 500 mbar a (7.25 psia) Also available as vacuum-resistant remote seal: 30 mbar a (0.44 psi a) Upper measuring limit 100 % of max. span 100 % of the max. nominal measuring range Output signal 4 ... 20 mA • Lower limit (infinitely adjustable) • Upper limit (infinitely adjustable) 3.55 mA, factory preset to 3.84 mA 23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA Digital PROFIBUS PA and FOUNDATION Fieldbus signal - Output Load • Without HART RB (UH - 10.5 V)/0.023 A in , UH: Power supply in V RB = 230 ... 500 (SIMATIC PDM) or RB = 230 ... 1100 (HART Communicator) - Physical bus - IEC 61158-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. • With HART Set to 2 s (0 ... 100 s) Electrical damping (step width 0.1 s) Acc. to IEC 60770-1 Measuring accuracy Reference conditions (All error data refer always refer to the set span) - Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F) Span ratio r = max. span/set span) Nominal measuring range ratio r = nominal measuring range/set measuring range Error in measurement at limit setting incl. hysteresis and reproducibility • Linear characteristic - r 10 0.15 % 0.15 % - 10 < r 30 0.3 % 0.3 % - 30 < r 100 (0.0075 r + 0.075) % (0.0075 r + 0.075) % (0.25 r)% every 5 years static pressure max. 70 bar (1015 psi) (0.25 r)% every 5 years static pressure max. 70 bar (1015 psi) - 250 mbar- (100 inH2O)-measuring cell (0.5 r + 0.2) %1) 4) (0.5 r + 0.2) %1) 4) - 600 mbar- (240 inH2O)-measuring cell (0.3 r + 0.2) (0.3 r + 0.2) %2) 4) Long-term stability (temperature change ± 30 °C (± 54 °F)) Influence of ambient temperature • at -10 ... +60 °C (14 ... 140 °F) %2) 4) - 1600 and 5000 mbar- (642 and 2000 inH2O)- (0.25 r + 0.2) measuring cell %3) 4) (0.25 r + 0.2) %3) 4) • at -40 ... -10 °C and 60 ... 85 °C (-40 ... +14 °F and 140 ... 185 °F) - 250 mbar- (100 inH2O)-measuring cell (0.25 r + 0.15) %/10 K doubled values at 10 < r 30 (0.25 r + 0.15) %/10 K doubled values at 10 < r 30 - 600 mbar- (240 inH2O)-measuring cell (0.15 r + 0.15) %/10 K doubled values at 10 < r 30 (0.15 r + 0.15) %/10 K doubled values at 10 < r 30 - 1600 and 5000 mbar- (642 and 2000 inH2O)- (0.12 r + 0.15) %/10 K measuring cell double values at 10 < r 30 1/152 Siemens FI 01 · 2015 US Edition (0.12 r + 0.15) %/10 K double values at 10 < r 30 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level SITRANS P DS III for level HART PROFIBUS PA or FOUNDATION Fieldbus - 250 mbar- (100 inH2O)-measuring cell (0.3 r) % per nominal pressure (0.3 r) % per nominal pressure - 600 mbar- (240 inH2O)-measuring cell (0.15 r) % per nominal pressure (0.15 r) % per nominal pressure Influence of static pressure • on the zero point - 1600 and 5000 mbar- (642 and 2000 inH2O)- (0.1 r) % per nominal pressure measuring cell (0.1 r) % per nominal pressure • on the span (0.1 r) % per nominal pressure (0.1 r) % per nominal pressure Measured Value Resolution - 3 10-5 of nominal measuring range Rated conditions Degree of protection to IEC 60529 IP66 (optional IP66/IP68), NEMA 4X Note: Always take into account assignment of max. permissible operating temperature to max. permissible operating pressure of the respective flange connection! Temperature of medium -40 ... +1005) °C (-40 ... +2125) °F) • Measuring cell with silicone oil filling - High-pressure side pabs 1 bar: -40 ... +175 °C (-40 ... +347 °F) pabs < 1 bar: -40 ... +80 °C (-40 ... +176 °F) - Low-pressure side -40 ... +100 °C (-40 ... +212 °F) -20 ... +60 °C (-4 ... +140 °F) in conjunction with dust explosion protection Ambient conditions • Ambient temperature - Transmitter (with 4-wire connection, observe temperature values of supplementary 4-wire electronics) -40 ... +85 °C (-40 ... +185 °F) - -Display readable -30 ... +85 °C (-22 ... +185 °F) • Storage temperature -50 ... +85 °C (-58 ... +185 °F) • Climatic class - Condensation Relative humidity 0 ... 100 %, condensation permissible, suitable for use in the tropics • Electromagnetic Compatibility - Emitted interference and interference immunity Acc. to IEC 61326 and NAMUR NE 21 Design Weight (without options) • To EN (pressure transmitter with mounting flange, without tube) 11 ... 13 kg ( 24.2 ... 28.7 (lb) • To ASME (pressure transmitter with mounting flange, without tube) 11 ... 18 kg ( 24.2 ... 39.7 lb) Low-copper die-cast aluminum, GD-AlSi12 or stainless steel precision casting, mat. no. 1.4408 Enclosure material Wetted parts materials High-pressure side • Seal diaphragm of mounting flange Stainless steel, mat. no. 1.4404/316L, Monel, mat. no. 2.4360, Hastelloy B2, mat. no. 2.4617, Hastelloy C276, mat. no. 2.4819, Hastelloy C4, mat. no. 2.4610, tantalum, PTFE, ETCFE, stainless steel Duplex, mat. no. 1.4462 Measuring cell filling Silicone oil Process connection • High-pressure side Flange to EN and ASME • Low-pressure side Female thread ¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/ -20 UNF to EN 61518 16 Supplied through bus Power supply UH Terminal voltage on transmitter 10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode - Separate 24 V power supply necessary - No • Not Ex - 9 ... 32 V • With intrinsically-safe operation - 9 ... 24 V Bus voltage Current consumption • Basic current (max.) - 12.5 mA • Start-up current basic current - Yes • Max. current in event of fault - 15.5 mA Fault disconnection electronics (FDE) available - Yes Siemens FI 01 · 2015 US Edition 1/153 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for level SITRANS P DS III for level HART PROFIBUS PA or FOUNDATION Fieldbus Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection • Intrinsic safety "i" PTB 13 ATEX 2007 X Ex II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Marking - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF • Explosion-proof "d" PTB 99 ATEX 1160 - Marking Ex II 1/2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature - Connection -40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 To circuits with values: UH = 10.5 ... 45 V DC • Dust explosion protection for zone 20 To circuits with values: UH = 9 ... 32 V DC PTB 01 ATEX 2055 - Marking Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C - Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) - Max. surface temperature 120 °C (248 °F) - Connection To certified intrinsically-safe circuits with peak values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF L i = 7 H, Ci = 1.1 nF PTB 01 ATEX 2055 • Dust explosion protection for zone 21/22 - Marking Ex II 2 D IP65 T 120 °C - Connection To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W • Type of protection "n" (zone 2) To circuits with values: UH = 9 ... 32 V DC; Pmax = 1 W PTB 13 ATEX 2007 X Ex II 2/3 G Ex nA II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Marking - Connection (Ex nA) Um = 45 V Um = 32 V - Connection (Ex ic) To circuits with values: Ui = 45 V FISCO supply unit ic: Uo = 17.5 V, Io = 570 mA Linear barrier: Uo = 32 V, Io = 132 mA, Po = 1 W - Effective internal inductance/capacitance L i = 0.4 mH, Ci = 6 nF • Explosion protection acc. to FM - Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III • Explosion protection to CSA - Identification (XP/DIP) or (IS) L i = 7 H, Ci = 1.1 nF Certificate of Compliance 3008490 Certificate of Compliance 1153651 CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III 1) Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.4 · r + 0.16) % / 28 °C (50 °F). 2) Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.24 · r + 0.16) % / 28 °C (50 °F). 3) Conversion of temperature error per 28 °C. Valid for temperature range -3 ... +53 °C < (0.2 · r + 0.16) % / 28 °C (50 °F). 4) 0.32 instead of 0.16 at 10 < r < 30 5) This value may be increased if the process connection is sufficiently insulated. 1/154 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level HART communication HART 230 ... 1100 Protocol HART Version 5.x Software for computer SIMATIC PDM PROFIBUS PA communication Simultaneous communication with master class 2 (max.) 4 The address can be set using Configuration tool or local operation (standard setting address 126) Cyclic data usage • Output byte 5 (one measured value) or 10 (two measured values) • Input byte 0, 1, or 2 (register operating mode and reset function for metering) Internal preprocessing FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, 1 function block PID • Analog input - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0 ... 100 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic for flow measurement Yes Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, class B • PID Standard FOUNDATION Fieldbus function block • Physical block 1 resource block Function blocks 2 Transducer blocks - Adaptation to customer-specific process variables Yes, linearly rising or falling characteristic 1 transducer block Pressure with calibration, 1 transducer block LCD • Pressure transducer block - Electrical damping, adjustable 0 ... 100 s - Simulation function Input/Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively • Analog input • Register (totalizer) - Failure mode - Limit monitoring Can be reset, preset, optional direction of counting, simulation function of register output parameterizable (summation with last good value, continuous summation, summation with incorrect value) One upper and lower warning limit and one alarm limit respectively • Physical block 1 Transducer blocks 2 - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Mounting flange Nominal diameter Nominal pressure • Acc. to EN 1092-1 - DN 80 PN 40 - DN100 PN16, PN40 • To ASME B16.5 - 3 inch class 150, class 300 - 4 inch class 150, class 300 • Pressure transducer block - Can be calibrated by applying two pressures Yes - Monitoring of sensor limits Yes - Specification of a container characteristic with Max. 30 nodes - Square-rooted characteristic for flow measurement Yes - Gradual volume suppression and implementation point of square-root extraction Parameterizable - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function Siemens FI 01 · 2015 US Edition 1/155 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for level Selection and Ordering data Article No. Pressure transmitter for level, SITRANS P DS III with HART 7MF 4 6 3 3 77 Y 77 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning normal Measuring span (min. ... max.) 25 ... 250 mbar (10 ... 100 inH2O) 25 ... 600 mbar (10 ... 240 inH2O) 53 ... 1600 mbar (21 ... 642 inH2O) 0.16 ... 5 bar (64.3 ... 2000 inH2O) Process connection of low-pressure side Female thread ¼-18 NPT with flange connection • Mounting thread 7/16-20 UNF to IEC 61518 • Mounting thread M10 to DIN 19213 (only for replacement requirement) 1 Die-cast aluminum Stainless steel precision casting1) Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"2) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"3) - "Ex nA/ic (Zone 2)" 4) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia+ Ex d + Zone 1D/2D)"3)5) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)5) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"1) Electrical connection/cable entry • Screwed gland Pg 13.56) • Screwed gland M20x1.5 • Screwed gland ½-14 NPT • Han 7D plug (plastic housing) incl. mating connector6) • M12 connectors (stainless steel) 7) 8) Display • Without display • Without visible display (display concealed, setting: mA) • With visible display (setting mA) • With customer-specific display (setting as specified, Order code "Y21" or "Y22" required) 1/156 Siemens FI 01 · 2015 US Edition Ordering example Item line 1: 7MF4633-1EY20-1AA1-Z B line: Y01 C line: Y01: 80 to 143 mbar (1.16 to 2.1 psi) Item line 2: 7MF4912-3GE01 Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) D E F G 2 0 Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel Ordering information 1st order item: Pressure transmitter 7MF4633-... 2nd order item: Mounting flange 7MF4912-3... 2 3 1 2 A B D P E R F S NC A B C D F 0 1 6 7 1) Not in conjunction with electrical connection "Screwed gland Pg 13.5" and "Han7D plug". 2) Without cable gland, with blanking plug. 3) With enclosed cable gland Ex ia and blanking plug. 4) Configurations with HAN and M12 connectors are only available in Ex ic. 5) Only in connection with IP65. 6) Only in connection with Ex approval A, B or E. 7) M12 delivered without cable socket 8) Only in connection with Ex approval A, B, E or F. © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level Selection and Ordering data Article No. Ordering information 1st order item: Pressure transmitter 7MF4634-... 2nd order item: Mounting flange 7MF4912-... Pressure transmitters for level SITRANS P DS III with PROFIBUS PA (PA) 7MF 4 6 3 4 - SITRANS P DS III with FOUNDATION Fieldbus (FF) 7MF 4 6 3 5 - Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Nominal measuring range 250 mbar (100 inH2O) 600 mbar (240 inH2O) 1600 mbar (642 inH2O) 5 bar (2000 inH2O) Process connection of low-pressure side Female thread ¼-18 NPT with flange connection • Mounting thread 7/16-20 UNF to IEC 61518 • Mounting thread M10 to DIN 19213 (only for replacement requirement) 1 7 Y 77 - 7777 Ordering example Item line 1: 7MF4634-1EY20-1AA1 Item line 2: 7MF4912-3GE01 Included in delivery of the device: • Brief instructions (Leporello) • CD-ROM with detailed documentation • Sealing plug(s) or sealing screw(s) for the process flanges(s) D E F G 2 0 1) Without cable gland, with blanking plug. 2) With enclosed cable gland Ex ia and blanking plug. 3) Configurations with HAN and M12 connectors are only available in Ex ic. 4) Only in connection with IP65. 5) M12 delivered without cable socket 6) Only in connection with Ex approval A, B, E or F. Non-wetted parts materials process flange screws Electronics housing Stainless steel Stainless steel Die-cast aluminum Stainless steel precision casting Version • Standard versions • International version, English label inscriptions, documentation in 5 languages on CD (no Order code selectable) Explosion protection • None • With ATEX, Type of protection: - "Intrinsic safety (Ex ia)" - "Explosion-proof (Ex d)"1) - "Intrinsic safety and flameproof enclosure" (Ex ia + Ex d)"2) - "Ex nA/ic (Zone 2)" 3) - "Intrinsic safety, explosion-proof enclosure and dust explosion protection (Ex ia + Ex d + Zone 1D/2D)"2)4) (not for DS III FF) • FM + CSA intrinsic safe (is) • FM + CSA (is + ep) + Ex ia + Ex d (ATEX)4) • With FM + CSA, Type of protection: - "Intrinsic Safe und Explosion Proof (is + xp)"1) Electrical connection/cable entry • Screwed gland M20 x 1.5 • Screwed gland ½-14 NPT • M12 connectors (stainless steel)5) 6) Display • Without display • Without visible display (display concealed, setting: bar) • With visible display (setting: bar) • With customer-specific display (setting as specified, Order code "Y21" required) 2 3 1 2 A B D P E R F S NC B C F 0 1 6 7 Siemens FI 01 · 2015 US Edition 1/157 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for level Selection and Ordering data Order code Further designs Selection and Ordering data HART PA FF Add "-Z" to Article No. and specify Order code. Add "-Z" to Article No. and specify Order code. O-rings for process flanges on low-pressure side (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Use on zone 1D / 2D (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-.....-.B.. Ex ia)“and IP65) Plug • Han 7D (metal) • Han 8D (instead of Han 7D) • Angled • Han 8D (metal) A20 A21 A22 A23 A30 A31 A32 A33 Sealing screw ¼-18 NPT, with valve in mat. of process flanges A40 A50 Cable sockets for M12 connectors (metal (CuZn)) Rating plate inscription (instead of German) • English • French • Spanish • Italian • Cyrillic (russian) Order code Further designs HART PA E01 Overfilling safety device for flammable and E08 non-flammable liquids (max. PN 32 (MAWP 464 psi), basic device with type of protection "Intrinsic safety (Ex ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") Export approval Korea E11 CRN approval Canada (Canadian Registration Number) E22 Dual seal E24 FF Explosion-proof "Intrinsic safety" (Ex ia) to E252) INMETRO (Brazil) (only for transmitter 7MF4...-.....-.B..) "Flameproof" explosion protection accord- E262) ing to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.D..) B11 B12 B13 B14 B16 Explosion-proof "Intrinsic safety" (Ex ia + Ex d) to INMETRO (Brazil) (only for transmitter 7MF4...-.....-.P..) E282) Ex Approval IEC Ex (Ex ia) (only for transmitter 7MF4...-.....-.B..) E452) English rating plate Pressure units in inH20 and/or psi B21 Ex Approval IEC Ex (Ex d) (only for transmitter 7MF4...-.....-.D..) E462) Quality inspection certificate (Five-step factory calibration) to IEC 60770-2 C11 E552) Inspection certificate Acc. to EN 10204-3.1 C12 Explosion-proof "Intrinsic safety" to NEPSI (China) (only for transmitter 7MF4...-.....-.B..) C14 Explosion protection "Explosion-proof" to E562) NEPSI (China) (only for transmitter 7MF4...-.....-.D..) Factory certificate Acc. to EN 10204-2.2 Functional safety (SIL2) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C20 E572) Functional safety (PROFIsafe) Certificate and PROFIsafe protocol C211) Ex protection „Ex ia“, „Ex d“ and „Zone 2“ E582) to NEPSI (China) (only for transmitter 7MF4...-.....-.R..) Functional safety (SIL2/3) Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration C23 "Intrinsic safety" and "Explosion-proof" explosion protection acc. to Kosha (Korea) (only for transmitter 7MF4...-.....-.[B, D]..-Z + E11) E702) Device passport Russia C99 Two coats of lacquer on casing and cover (PU on epoxy) G10 Replacement of process connection side Ex protection "Zone 2" to NEPSI (China) (only for transmitter 7MF4...-.....-.E..) (For price request please contact the technical support www.siemens.com/automation/support-request) Setting of upper limit of output signal to 22.0 mA D05 Degree of protection IP66/IP68 (only for M20x1.5 and ½-14 NPT) D12 Supplied with oval flange (1 item), PTFE packing and screws in thread of process flange D37 Capri cable gland 4F CrNi and clamping device (848699 + 810634) included D59 H01 Transient protector 6 kV (lightning protec- J01 tion) Vent valve or blanking plug of process flange welded-in (orientation: on right when viewing the display)3) J08 J09 Vent valve or blanking plug of process flange welded-in (orientation: on left when 3) viewing the display) 1) Profisafe transmitters can only be operated with the S7 F Systems V6.1 configuration software in combination with S7-400H Option beinhaltet keine ATEX-Zulassung, sondern nur die landesspezifische Zulassung. 3) Blanking plug is standard configuration. Order option A40 if a vent valve is required instead of a blanking plug. 2) 1/158 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Measuring range to be set Specify in plain text (max. 5 characters): Y01: ... up to ... mbar, bar, kPa, MPa, psi Y01 1) Stainless steel tag plate and entry in device variable (measuring point description) Max. 16 characters, specify in plain text: Y15: ........................................... Y15 Measuring point text (entry in device variable) Max. 27 characters, specify in plain text: Y16: ........................................... Y16 Entry of HART address (TAG) Max. 8 characters, specify in plain text: Y17: ........................................... Y17 Setting of pressure indicator in pressure Y21 units Specify in plain text (standard setting: bar): Y21: mbar, bar, kPa, MPa, psi, ... Note: The following pressure units can be selected: bar, mbar, mm H2O*), inH2O*), ftH2O*), mmHG, inHG, psi, Pa, kPa, MPa, g/cm2, kg/cm2, Torr, ATM or % *) ref. temperature 20 °C Setting of pressure indicator in Y223) non-pressure units2) + Y01 Specify in plain text: 3/h, m, USgpm, ... Y22: ..... up to ..... l/min, m (specification of measuring range in pressure units "Y01" is essential, unit with max. 5 characters) Preset bus address possible between 1 and 126 Specify in plain text: Y25: ........................................... Y25 Damping adjustment in seconds (0 ... 100 s) Y30 Only Y01, Y15, Y16, Y17, Y21, Y22, Y25 and D05 can be factory preset = available 1) Measuring accuracies for PROFIBUS PA transmitters with Option Y01 are calculated in the same way as for HART devices. Preset values can only be changed over SIMATIC PDM. 3) Not in conjunction with over-filling safety device for flammable and nonflammable liquids (Order code "E08") 2) Siemens FI 01 · 2015 US Edition 1/159 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III for level Selection and Ordering data Article No. Ord. code Selection and Ordering data Mounting flange 7MF 4 9 1 2 - Further designs Directly mounted on the SITRANS P pressure transmitter (converter part) for level, for DS III series 3 7777 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Connection to EN 1092-1 Nominal diameter Nominal pressure DN 50 PN 10/16/25/40 PN 100 A B DN 80 PN 10/16/25/40 D DN 100 PN 10/16 PN 25/40 G H Connection to ASME B16.5 Nominal diameter Nominal pressure 2 inch class 150 class 300 class 400/600 class 900/1500 3 inch class 150 class 300 4 inch class 150 class 300 Other version, add Order code and plain text: Nominal diameter: ...; Nominal press.: ... Wetted parts materials • Stainless steel 316L - Coated with PFA - Coated with PTFE • Coated with ECTFE1) • Monel 400, mat. no. 2.4360 • Hastelloy C276, mat. no. 2.4819 • Hastelloy C4, mat. no. 2.4610 • Tantalum • Duplex 2205, mat. no. 1.4462 • Duplex 2205, mat. no. 1.4462, incl. main body • Stainless steel 316L, gold plated, thickness approx. 25 m Tube length • None • 50 mm (1.97 inch) • 100 mm (3.94 inch) • 150 mm (5.90 inch) • 200 mm (7.87 inch) Other version: add Order code and plain text: material of parts in contact with medium: ........, tubus length: ........ Filling liquid • Silicone oil M5 • Silicone oil M50 • High-temperature oil • Halocarbon oil (for O2-measurement) • Food oil (FDA-listed) Other version, add Order code and plain text: filling liquid: ... 1) For vacuum on request 1/160 Siemens FI 01 · 2015 US Edition L M N P Q R T U Z J1Y A D E0 F G J U K Q R S0 0 1 2 3 4 Z8 K1Y 1 2 3 4 7 9 M1 Y Order code HART PA FF Add "-Z" to Article No. and specify Order code. Spark arrester A01 For mounting on zone 0 (incl. documentation) Remote seal nameplate attached out of stainless steel, contains Article No. and order number of the remote seal supplier B20 Oil- and grease-free cleaned version C10 Oil- and grease-free cleaned and packed version, not for oxygen application, only in conjunction with halocarbon oil fill fluid, certified by certificate acc. to EN 10204-2.2 Quality inspection certificate (Five-step factory calibration) to IEC 60770-2 C11 Inspection certificate Acc. to EN 10204-3.1 C12 2.2 Certificate of FDA approval of fill oil C17 Only in conjunction with filling liquid "Food oil" (FDA listed)" "Functional safety (SIL2)" certificate C20 to IEC 61508 "Functional safety (SIL2/3)" certificate C23 to IEC 61508 (only for conjunction with the Order code "C23" in the case of SITRANS P DS III transmitter) Certification acc. to NACE MR-0175 D07 Includes acceptance test certificate 3.1 acc. to EN 10204 (only for wetted parts made of stainless steel 1.4404/316L and Hastelloy C276) Certification acc. to NACE MR-0103 D08 Includes acceptance test certificate 3.1 acc. to EN 10204 (only for wetted parts made of stainless steel 1.4404/316L and Hastelloy C276) Oil- and grease-free cleaned version E10 Oil- and grease-free cleaned and packed version, only for oxygen application, only inert fill fluid may be used. Max. temperature: 60 °C (140 °F), max. pressure 50 bar (725 psi), only in connection with halocarbon oil, certified by certificate acc. to EN 10204-2.2 Epoxy painting E15 Not possible with vacuum-proof design Color: transparent, coverage: front and rear of the remote seal, capillary(ies) or connecting tube, process connection of the transmitter. With transmitters 7MF40.. and 7MF42.., only possible with process connection G½B according to EN837-1. Sealing surface B1 or J12 ASME B16.5 RF 125 ... 250 AA instead of sealing surface B2 or RFSF (only for wetted parts made of Hastelloy C276 (2.4819), tantalum and Duplex 2205 (1.4462) and for nominal sizes 2", 3", DN 50 and DN 80) Sealing surface groove, EN 1092-1, form D J14 instead of sealing surface B1 (only for wetted parts made of stainless steel 316L) Sealing surface RJF (groove) ASME B16.5 J24 instead of sealing surface ASME B16.5 RF 125 ... 250 AA (only for wetted parts made of stainless steel 316L) (only for conjunction with the Order code "C20" in the case of SITRANS P DS III transmitter) © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order code. Elongated pipe, 150 mm instead of 100 mm, R15 max. medium temperature 250 °C, observe the maximum permissible media temperature of the filling liquid. Elongated pipe, 200 mm instead of 100 mm, R20 max. medium temperature 300 °C, observe the maximum permissible media temperature of the filling liquid. Vacuum-proof design (for use in low-pressure range) Note: suffix "Y01" required with press. transm. = available V04 Siemens FI 01 · 2015 US Edition 1/161 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level ■ Dimensional drawings 29 (1.14) 5) 177 (6.97) 84 (3.31) 53 (2.1) 2 3 1 143 (5.6) 74 (2.9) 5 15 (0.6) 6 166 (6.54) 4 Øk ØD Ød4 min. 90 (3.54) 4) Ød 5 1 9 54 (2.1) approx. 96 (3.78) 108 (4.25) 17 (0.67) 7 n x d2 b f L 1 8 1 Electrical connection: Screwed gland Pg 13,5 (adapter)(Adapter)2) 3), Screwed gland M20 x 1,5 or Screwed gland ½-14 NPT or Han 7D/Han 8D2) 3) plug 2 Protective cover over keys 3 Blanking plug 4 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 5 Terminal side1) 6 Electronic side, digital display (longer overall length for cover with window)1) 7 Sealing screw with valve (option) 8 Harting adapter 9 Process connection of low pressure side ¼-18 NPT (IEC 61518) 1) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing Not with type of protection "Explosion-proof enclosure" Not with type of protection "FM + CSA" [IS + XP]" 92 mm (3.62 inch) for minimum distance to permit rotation with indicator For Pg 13,5 with adapter approx. 45 mm (1.77 inch) 2) 3) 4) 5) SITRANS P DS III with HART pressure transmitters for level, including mounting flange, dimensions in mm (inch) 1/162 Siemens FI 01 · 2015 US Edition Space for rotation of housing © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III for level Connection to EN 1092-1 Nominal diameter Nominal pressure DN 50 PN 10/16/ 25/40 DN 80 DN 100 b D d d2 d4 d5 dM f k n L mm mm mm mm mm mm mm mm mm mm mm 20 165 90 18 102 48.3 451) 2 125 8 0, 50, 100, 150 or 200 PN 100 28 195 90 26 102 48.3 451) 2 145 8 PN 10/16/ 25/40 24 200 90 18 138 76 722) 2 160 8 PN 100 32 230 90 26 138 76 722) 2 180 8 PN 10/16 20 220 115 18 158 94 89 2 180 8 PN 25/40 24 235 115 22 162 94 89 2 190 8 Connection to ASME B16.5 Nominal diameter Nominal pressure b lb./sq.in inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) 2 inch 150 0.77 (19.5) 5.91 (150) 0.79 (20) 3.62 (92) 1.9 (48.3) 1.771) (45) 0.08 (2) 4.74 (120.5) 4 300 0.89 (22.7) 6.5 (165) 0.79 (20) 3.62 (92) 1.9 (48.3) 1.771) (45) 0.08 (2) 5 (127) 8 400/600 1.28 (32.4) 6.5 (165) 0.79 (20) 3.62 (92) 1.9 (48.3) 1.771) (45) 0.28 (7) 5 (127) 8 900/1500 1.78 (45.1) 8.46 (215) 1.02 (26) 5 (127) 1.9 (48.3) 1.771) (45) 0.28 (7) 6.5 (165) 8 4 3 inch 4 inch D d2 d4 d5 dM f k n inch (mm) 150 0.96 (24.3) 7.48 (190) 0.79 (20) 5 (127) 3 (76) 2.832) (72) 0.08 (2) 6 (152.5) 300 1.14 (29) 8.27 (210) 0.87 (22) 5 (127) 3 (76) 2.832) (72) 0.08 (2) 6.63 (168.5) 8 600 1.53 (38.8) 8.27 (210) 0.87 (22) 5 (127) 3 (76) 2.832) (72) 0.28 (7) 6.63 (168.5) 8 150 0.96 (24.3) 9.06 (230) 0.79 (20) 6.22 (158) 3.69 (94) 3.5 (89) 0.08 (2) 7.5 (190.5) 8 300 1.27 (32.2) 10.04 (255) 0.87 (22) 6.22 (158) 3.69 (94) 3.5 (89) 0.08 (2) 7.87 (200) 8 400 1.65 (42) 6.22 (158) 3.69 (94) 3.5 (89) 0.28 (7) 7.87 (200) 8 10.04 (255) 1.02 (26) L 0, 2, 3.94, 5.94 or 7.87 (0, 50, 100, 150 or 200) d: Internal diameter of gasket to DIN 2690 dM: Effective diaphragm diameter 1) 59 mm = 2.32 inch with tube length L=0. 2) 89 mm = 3½ inch with tube length L=0. Siemens FI 01 · 2015 US Edition 1/163 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III Supplementary electronics for 4-wire connection ■ Overview Structural design Dimensions (W x H x D) in mm (inch) 80 x 120 x 60 (3.15 x 4.72 x 2.36) Electrical connection Screw terminals (Pg 13.5 cable inlet) or Han 7D / Han 8D plug Power supply Supply voltage 230 V AC (-10 ... +6 %, 47 ... 63 Hz, approx. 6 VA) or 24 V AC/DC (24 V AC 10 %, 47 ... 63 Hz, approx. 3 VA) Permissible ripple (within the specified limits) Approx. 2.5 V pp ■ Dimensional drawings 212 (8.35) 80 (3.15) Direct connection of the supplementary electronics to a SITRANS P DS III pressure transmitter with HART produces a transmitter for 4-wire connection. The supplementary electronics cannot be attached to explosionprotected pressure transmitters. The supplementary electronics is fitted in a light metal housing which is mounted on the left side of the pressure transmitter. Note on ordering: The supplementary electronics can only be ordered as an optional accessory for the corresponding pressure transmitter. ■ Technical specifications SITRANS P, supplementary electronics for 4-wire connection Output Output signal 0 ... 20 mA or 4 ... 20 mA Load Max. 750 Voltage measurement Linear (square-rooting in transmitter if necessary) Electrical isolation Between power supply and input/ output Measuring accuracy acc. to IEC 60770-1 Measurement deviation (in addition to transmitter) 0.15 % of set span Influence of ambient temperature 0.1 % per 10 K Power supply effect 0.1 % per 10 % change in voltage or frequency Load effect 0.1 % per 100 % change Rated conditions Ambient temperature • 24 V version -20 ... +80 °C (-4 ... +176 °F) • 230 V version -20 ... +60 °C (-4 ... +140 °F) Storage temperature -50 ... +85 °C (-58 ... +185 °F) Degree of protection IP54 to IEC 60529 Electromagnetic compatibility (EMC) IEC 61236 Condensation Relative humidity 0 ... 95 % condensation permissible 1/164 Siemens FI 01 · 2015 US Edition 114 (4.5) SITRANS P pressure transmitters with supplementary electronics for fourwire connection, dimension drawing, dimensions in mm © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III Supplementary electronics for 4-wire connection ■ Schematics 1 Terminals 2 + 3 Ia 1 Han 8D/7D plug 6 7 5 1 4 6 7 5 1 4 5 UH 6 SL Supplementary electronics for 4-wire connection Article No. of the transmitter 7MF4.33-.....-.AB. add "-Z" and Order code. V77 Power supply 24 V AC/DC SL 2 Ia - UH 6 7 2 5 1 3 4 + Ia - SL 2 3 UH AC 230 V UC 24 V Han 7D Han 7D Han 7D Han 8D Ia SL UH Power supply Output current Order code 3 + 2 plugs 4 - Selection and Ordering data Protective earth conductor Supplementary electronics for 4-wire connection, connection diagram 230 V AC Electrical connection Terminals; 2 Pg screwed glands, to left 2 Han 7D/Han 8D plugs incl. mating connector, to left 1 Han 7D plug incl. mating connector, angled Terminals; 1 Pg screwed gland, downwards 1 Han 8D plug incl. mating connector, downwards (observe arrangement of plug and differential pressure line) Terminals; 2 Pg screwed glands, to left 2 Han 7D plugs incl. mating connector, to left Output current 0 ... 20 mA 4 ... 20 mA 1 3 5 6 9 7 8 0 1 Accessories Instruction Manual German/English A5E00322799 Siemens FI 01 · 2015 US Edition 1/165 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III Accessories/Spare Parts Selection and Ordering data Article No. Selection and Ordering data Article No. Replacement measuring cell for pressure for SITRANS P DS III 7MF 4 9 9 0 - Replacement measuring cell for absolute pressure for SITRANS P DS III (from the pressure series) 7777 0 - 0 DB 0 7777 0 - 0 DB 0 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil Normal Inert liquid grease-free to cleanliness level 2 Measured span (min. ... max.) 0.01 ... 1 bar (0.15 ... 14.5 psi) 0.04 ... 4 bar (0.6 ... 58 psi) 0.16 ... 16 bar (2.32 ... 232 psi) 0.63 ... 63 bar (9.14 ... 914 psi) 1.6 ... 160 bar (23.2 ... 2320 psi) 4.0 ... 400 bar (58.0 ... 5802 psi) 7.0 ... 700 bar (102.0 ... 10153 psi) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil Normal Inert liquid grease-free to cleanliness level 2 1 3 Measured span (min. ... max.) 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psia) 0.16 ... 5 bar a (2.32 ... 72.5 psia) 1 ... 30 bar a (14.5 ... 435 psia) B C D E F G J Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy A B C Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel, max. span 160 bar (2320 psi) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 Further designs 0 1 2 3 Order code Please add "-Z" to Article No. and specify Order code. Inspection certificate to EN 10204-3.1 1/166 Siemens FI 01 · 2015 US Edition 1 3 D F G H Wetted parts materials Seal diaphragm Process connection Wetted parts materials Seal diaphragm Process connection Stainless steel Hastelloy Hastelloy 7MF 4 9 9 2 - C12 Stainless steel Stainless steel Hastelloy A B C Process connection • Connection shank G½B to EN 837-1 • Female thread ½-14 NPT • Oval flange made of stainless steel, max. span 160 bar (2320 psi) - Mounting thread 7/16-20 UNF to IEC 61518 - Mounting thread M10 to DIN 19213 Further designs 0 1 2 3 Order code Please add "-Z" to Article No. and specify Order code. Inspection certificate to EN 10204-3.1 C12 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III Accessories/Spare Parts Selection and Ordering data Article No. Selection and Ordering data Article No. Replacement measuring cell for absolute pressure (from the differential pressure series) for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus series 7MF 4 9 9 3 77777 - 0 DC 0 Replacement measuring cell for differential pressure and PN 32/160 (MAWP 464/2320 psi) for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus series 77777 - 0 DC 0 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil Normal Inert liquid grease-free to cleanliness level 2 Measured span (min. ... max.) 8.3 ... 250 mbar a (0.12 ... 3.62 psia) 43 ... 1300 mbar a (0.62 ... 18.85 psia) 0.16 ... 5 bar a (2.32 ... 72.5 psia) 1 ... 30 bar a (14.5 ... 435 psia) 5.3 ... 100 bar a (76.9 ... 1450 psia) Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Measuring cell cleaning Silicone oil Normal Inert liquid grease-free to cleanliness level 2 Measured span (min. ... max.) PN 32 (MAWP 464 psi) 1 ... 20 mbar1) (0.4 ... 8 inH2O) 1 3 D F G H KE PN 160 (MAWP 2320 psi) 1 ... 60 mbar (0.4 ... 24 inH2O) 2.5 ... 250 mbar (1 ... 100 inH2O) 6 ... 600 mbar (2.4 ... 240 inH2O) 16 ... 1600 mbar (6.4 ... 642 inH2O) 50 ... 5000 mbar (20 ... 2000 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) Wetted parts materials Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Hastelloy Tantalum Monel Gold Stainless steel Stainless steel Hastelloy Tantalum Monel Gold A B C E H L Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to IEC 61518 • Vent on side of process flange1) - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to IEC 61518 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) 1 3 B C D E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm 0 2 4 6 Non-wetted parts materials • Stainless steel process flange screws Further designs Please add "-Z" to Article No. and specify Order code. 7MF 4 9 9 4 - 2 Order code Parts of measuring cell Stainless steel Stainless steel Hastelloy Stainless steel Hastelloy Hastelloy 2) Tantalum Tantalum 2) Monel Monel 2) Gold Gold Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to IEC 61518 • Vent on side of process flange - Mounting thread M10 to DIN 19213 - Mounting thread 7/16-20 UNF to IEC 61518 A B C E H L 0 2 4 6 Non-wetted parts materials Stainless steel process flange screws Further designs Please add "-Z" to Article No. and specify Order code. A20 A21 A22 A23 O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) Inspection certificate to EN 10204-3.1 2 Order code A20 A21 A22 Inspection certificate to EN 10204-3.1 C12 Process connection G½B D16 Remote seal flanges (not together with K01, K02 and K04) D20 Remote seal flanges (not together with K01, K02 and K04) D20 Vent on side for gas measurements H02 Vent on side for gas measurements H02 H03 K00 Stainless steel process flanges for vertical differential pressure lines (not together with K01, K02 and K04) Process flanges • without • with process flange made of - Hastelloy - Monel - Stainless steel with PVDF insert max. PN 10 (MAWP 145 psi) max.temperature of medium 90 °C (194 °F) For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible 1) Not for span 5.3 ... 100 bar (76.9 ... 1450 psi) K01 K02 K04 Process flanges • without • with process flange made of - Hastelloy - Monel - Stainless steel with PVDF insert, max. PN 10 (MAWP 145 psi), max. temperature of medium 90 °C (194 °F). For ½-14 NPT inner process connection on the side in the middle of the process flange, vent valve not possible 1) 2) A23 C12 K00 K01 K02 K04 Not suitable for connection of remote seal Only together with max. spans 250, 1600, 5000 and 30000 mbar (100 inH2O, 642 inH2O, 2000 inH2O und 435 psi). Siemens FI 01 · 2015 US Edition 1/167 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III Accessories/Spare Parts Selection and Ordering data Article No. Replacement measuring cell for differential pressure and PN 420 (MAWP 6092 psi) for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus series 77777 - 0 DC 0 7MF 4 9 9 5 - Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring cell filling Silicone oil Measuring cell cleaning Normal Measured span (min. ... max.) 2.5 ... 250 mbar (1 ... 100 inH2O) 6 ... 600 mbar (2.4 ... 240 inH2O) 16 ... 1600 mbar (6.4 ... 642 inH2O) 50 ... 5000 mbar (20 ... 2000 inH2O) 0.3 ... 30 bar (4.35 ... 435 psi) 1 D E F G H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Hastelloy Gold1) Stainless steel Stainless steel Gold A B L Process connection Female thread ¼-18 NPT with flange connection • Sealing screw opposite process connection 1 3 - Mounting thread M12 to DIN 19213 - Mounting thread 7/16-20 UNF to IEC 61518 • Vent on side of process flange - Mounting thread M12 to DIN 19213 5 7 - Mounting thread 7/16-20 UNF to IEC 61518 Non-wetted parts materials • Stainless steel process flange screws Further designs 2 Order code Please add "-Z" to Article No. and specify Order code. O-rings for process flanges (instead of FPM (Viton)) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079), for measured medium temperatures -15 ... 100 °C (5 ... 212 °F) • NBR (Buna N) A20 A21 A22 A23 Inspection certificate to EN 10204-3.1 C12 Stainless steel process flanges for vertical differential pressure lines H03 without process flanges K00 1) Not together with max. span 600 mbar (240.9 inH2O) 1/168 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III Accessories/Spare Parts Selection and Ordering data Article No. Selection and Ordering data Spare parts/Accessories Mounting screws Mounting bracket and fastening parts for pressure transmitters SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF403.-.....-..C.) For absolute pressure transmitters SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF423.-.....-..C.) • made of steel • made of stainless steel For measuring point label, grounding and connection terminals or for display (50 units) Mounting bracket and fastening parts for pressure transmitters SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF403-.....-..A., -..B., ..D. and ..F.) For absolute pressure transmitters SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus 7MF423-.....-..A., -..B., ..D. and ..F.) • made of steel • made of stainless steel Mounting and fastening brackets For differential pressure transmitters with flange thread M10 SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF433.-... and 7MF443.-...) • made of steel • made of stainless steel Mounting and fastening brackets For differential pressure transmitters with flange thread M12 SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF453.-...) • made of steel • made of stainless steel Mounting and fastening brackets For differential and absolute pressure transmitters with flange thread 7/16 -20 UNF SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus (7MF433.-..., 7MF443.-... and 7MF453.-...) • made of steel • made of stainless steel 7MF4997-1AB 7MF4997-1AH 7MF4997-1AC 7MF4997-1AJ 7MF4997-1AD 7MF4997-1AK 7MF4997-1AE 7MF4997-1AL Cover made of die-cast aluminum, including gasket, for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus • without window • with window 7MF4997-1BB 7MF4997-1BE 7MF4997-1CD Sealing screws (1 set = 2 units) for process flange • made of stainless steel • made of Hastelloy 7MF4997-1CG 7MF4997-1CH Sealing screws with vent valve Complete (1 set = 2 units) • made of stainless steel • made of Hastelloy 7MF4997-1CP 7MF4997-1CQ Application electronics • for SITRANS P DS III with HART • for SITRANS P DS III with PROFIBUS PA • for SITRANS P DS III with FOUNDATION Fieldbus 7MF4997-1DK 7MF4997-1DL 7MF4997-1DM Connection board • for SITRANS P DS III • for SITRANS P DS III PROFIBUS PA and FOUNDATION Fieldbus 7MF4997-1DN 7MF4997-1DP O-rings for process flanges made of: • FPM (Viton) • PTFE (Teflon) • FEP (with silicone core, approved for food) • FFPM (Kalrez, compound 4079) • NBR (Buna N) 7MF4997-2DA 7MF4997-2DB 7MF4997-2DC 7MF4997-2DD 7MF4997-2DE Sealing ring for process connection see "Fittings" Weldable sockets for PMC connection • PMC Style Standard: Thread 1½" • PMC Style Minibolt: front-flush 1" 7MF4997-2HA 7MF4997-2HB Gaskets for PMC connection (packing unit = 5 units) • PTFE seal for PMC Style Standard: Thread 1½" • Gasket made of Viton for PMC Style Minibolt: front-flush 1" Weldable socket for TG52/50 and TG52/150 connection • TG52/50 connection • TG52/150 connection 7MF4997-1AF 7MF4997-1AM Article No. Seals for TG 52/50 and TG 52/150 made of silicone (FDA compliant) Seals for flange connection with front-flush diaphragm Material FPM (Viton), 10 units • DN 25, PN 40 (M11) • DN 25, PN 100 (M21) • 1", class 150 (M40) • 1", class 300 (M45) 7MF4997-2HC 7MF4997-2HD 7MF4997-2HE 7MF4997-2HF 7MF4997-2HG 7MF4997-2HH 7MF4997-2HJ 7MF4997-2HK 7MF4997-2HL Cover made of stainless steel, including gasket, for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus • without window • with window Digital indicator Including mounting material for SITRANS P DS III with HART, DS III with PROFIBUS PA and DS III with FOUNDATION Fieldbus Measuring point label • without inscription (5 units) • Printed (1 unit) Data according to Y01 or Y02, Y15, Y16 and Y99 (see "Pressure transmitters") 7MF4997-1BC 7MF4997-1BF 7MF4997-1BR 7MF4997-1CA 7MF4997-1CB-Z Y..: ...................... Siemens FI 01 · 2015 US Edition 1/169 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III Accessories/Spare Parts Selection and Ordering data Article No. Operating Instructions1) • for SITRANS DS III with HART - German - English - French - Spanish - Italian • for SITRANS DS III with PROFIBUS PA - German - English - French - Spanish - Italian • for SITRANS DS III with FOUNDATION Fieldbus - German - English Compact operating instructions • English, german, spanish, french, italian, dutch • English, estonian, latvian, lithuanian, polish, romanian • English, bulgarian, czech, finnish, slovakian, slovenian • English, danish, greek, portuguese, swedish, hungarian • Korean The compact operating instructions are available in 21 EU languages on the product CD supplied with each transmitter. They can also be downloaded from the SITRANS P web page. Brief instruction (Leporello) German, English • for SITRANS DS III with HART - German, English • for SITRANS DS III with PROFIBUS PA - German, English • for SITRANS DS III with FOUNDATION Fieldbus - German, English CD with SITRANS P documentation German, English, French, Spanish, Italian incl. compact operating instructions in 21 EU languages Certificates (order only via SAP) instead of Internet download • hard copy (to order) • on CD (to order) Operating Instructions for replacement of electronics, measuring cell and connection board (only available from the Internet)1) HART modem with USB interface Supplementary electronics for 4-wire connection A5E00047090 A5E00047092 A5E00053218 A5E00053219 A5E00053220 A5E00053275 A5E00053276 A5E00053277 A5E00053278 A5E00053279 A5E00279629 A5E00279627 A5E03434626 A5E03434631 A5E03434645 A5E03434656 A5E03693760 A5E00047093 A5E00053274 A5E00282355 A5E00090345 A5E03252406 A5E03252407 A5E00078060 7MF4997-1DB See page 1/164 Power supply units see Chap. 7 "Supplementary Components". 1) You can download these operating instructions free-of-charge from our Internet site at www.siemens.com/sitransp. 1/170 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III Accessories/Spare Parts ■ Dimensional drawings 60 30 25 12,5 25 30 Ø9 6 60 R30 12,5 3 134 21 105 120 52,5 72 16,5 R30 3 115 Ø11 72 Mounting bracket for SITRANS P DS III and SITRANS P280 gauge and absolute pressure-transmitters, dimensions in mm mounting bracket material: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) 38 27 54 20,65 R30 41,3 27 20,65 R6,5 Ø20 3 41,3 54 134 21 105 120 52,5 72 16,5 R30 3 115 Ø11 72 Mounting bracket for SITRANS P DS III differential pressure transmitter, dimensions in mm mounting bracket material: Sheet-steel Mat. No. 1.0330, chrome-plated, or stainless steel Mat. No. 1.4301 (304) Siemens FI 01 · 2015 US Edition 1/171 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements 1 SITRANS P DS III - Factory-mounting of valve manifolds on transmitters The 7MF9011-4FA valve manifolds are sealed with PTFE sealing tape between the transmitter and the valve manifold. ■ Overview SITRANS P transmitters • DS III for relative and absolute pressure (both designs) and • DS III for differential pressure The 7MF9411-5BA and 7MF9411-5CA valve manifolds are sealed with PTFE sealing rings between the transmitter and the valve manifold. can be delivered factory-fitted with the following valve manifolds: • 7MF9011-4EA and 7MF9011-4FA valve manifolds for gauge pressure and absolute pressure transmitters • 7MF9411-5BA and 7MF9411-5CA valve manifolds for absolute pressure and differential pressure transmitters Once installed, the complete unit is checked under pressure for leaks (compressed air 6 bar (87 psi)) and is certified leak-proof with a test report to EN 10204 - 2.2. ■ Design The 7MF9011-4EA valve manifolds are sealed with gaskets made of PTFE between transmitter and the valve manifold as standard. Soft iron, stainless steel and copper gaskets are also available for sealing purposes if preferred. All valve manifolds should preferably be secured with the respective mounting brackets. The transmitters are mounted on the valve manifold and not on the unit itself. If you order a mounting bracket when choosing the option "Factory mounting of valve manifolds", you will receive a mounting bracket for the valve manifold instead of a bracket for mounting the transmitter. If you order an acceptance test certificate 3.1 to EN10204 when choosing the option "Factory mounting of valve manifolds", a separate certificate is provided for the transmitters and the valve manifolds respectively. ■ Selection and Ordering data 7MF9411-5AA valve manifold for relative and absolute pressure transmitters Add „-Z“ to the Article No. of the transmit- Order ter and add order codes. code Add „-Z“ to the Article No. of the transmit- Order ter and add order codes. code SITRANS P DSIII T05 7MF403.-...2.-..., 7MF423.-...2.-... , 7MF403.-...3.-..., 7MF423.-...3.-... , 7MF403.-...4.-..., 7MF423.-...4.-... With process connection oval flange with PTFE gasket and steel mounting screws. Delivery including high-presure test certified by factory certificate according to EN 10204-2.2 SITRANS P DSIII T06 7MF403.-...2.-..., 7MF423.-...2.-... , 7MF403.-...3.-..., 7MF423.-...3.-... , 7MF403.-...4.-..., 7MF423.-...4.-... With process connection oval flange with PTFE gasket and stainless steel mounting screws. Delivery including high-presure test certified by factory certificate according to EN 10204-2.2 Additional versions: Delivery includes mounting brackets and mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) A02 Supplied acceptance test certificate to C12 EN 10204- 3.1 for transmitters and mounted valve manifold With manufacturer declaration according to NACE, MR-0175 1/172 7MF9411-5AA valve manifold for relative and absolute pressure transmitters Siemens FI 01 · 2015 US Edition D07 Additional versions: Delivery includes mounting brackets and mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) A02 Supplied acceptance test certificate to C12 EN 10204- 3.1 for transmitters and mounted valve manifold With manufacturer declaration according to NACE, MR-0175 D07 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Factory-mounting of valve manifolds on transmitters 7MF9011-4FA valve manifold on relative and absolute pressure transmitters 7MF9411-5BA valve manifold on absolute and differential pressure transmitters Add -Z to the Article No. of the transmitter Order and add Order codes code Add -Z to the Article No. of the transmitter Order and add Order codes code SITRANS P DSIII 7MF403.-...1.-..., 7MF423.-...1.-... With process connection female thread ½-14 NPT in-sealed with PTFE sealing tape Delivery incl. high-pressure test certified by test report to EN10204-2.2 SITRANS P DSIII 7MF433.-…, 7MF443.-… and 7MF453.-… 1) mounted with gaskets made of PTFE and screws made of • chromized steel • made of stainless steel Delivery incl. high-pressure test certified by test report to EN 10204-2.2 T03 Further designs: Delivery includes mounting brackets and A02 mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) Further designs: Delivery includes mounting bracket and mounting clips made of • Steel A01 • Stainless steel A02 (instead of the mounting bracket supplied with the transmitter) Supplied acceptance test certificate to EN C12 10204- 3.1 for transmitters and mounted valve manifold With manufacturer declaration according to NACE, MR-0175 D07 7MF9011-4EA valve manifold on relative and absolute pressure transmitters Add -Z to the Article No. of the transmitter Order and add Order codes code SITRANS P DSIII 7MF403.-...0.-..., 7MF423.-...0.-... with process connection collar G1/2 A to EN 837-1 with gasket made of PTFE between valve manifold and transmitter Alternative sealing material: • Soft iron • Stainless steel, Mat. No. 14571 • copper T02 U01 U02 Supplied acceptance test certificate to EN 10204-3.1 for transmitters and mounted valve manifold C12 With manufacturer declaration according to NACE, MR-0175 D07 7MF9411-5CA valve manifold on differential pressure transmitters Add -Z to the Article No. of the transmitter Order and add Order codes code SITRANS P DSIII 7MF443.-... and 7MF453.-…1 1) mounted with gaskets made of PTFE and screws made of • chromized steel • Stainless steel Delivery incl. high-pressure test certified by test report to EN 10204-2.2 A70 A71 A72 Delivery incl. high-pressure test certified by test report to EN 10204-2.2 U03 U04 Further designs: Further designs: Supplied acceptance test certificate to EN 10204- 3.1 for transmitters and mounted valve manifold C12 Delivery includes mounting bracket and mounting clips made of • Steel A01 • Stainless steel A02 (instead of the mounting bracket supplied with the transmitter) D07 Supplied acceptance test certificate to EN 10204-3.1 for transmitters and mounted valve manifold C12 With manufacturer declaration according to NACE, MR-0175 With manufacturer declaration according to NACE, MR-0175 D07 Delivery includes mounting brackets and A02 mounting clips made of stainless steel (instead of the mounting bracket supplied with the transmitter) 1) For 7MF453.-... transmitters, you require a 7/10-20 UNF connection thread in the process flange Siemens FI 01 · 2015 US Edition 1/173 1 © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Factory-mounting of valve manifolds on transmitters ■ Dimensional drawings Valve manifolds mounted on SITRANS P DS III 7MF9011-4EA valve manifold with mounted gauge pressure and absolute pressure transmitters 118 (4.65) 7MF9011-4FA valve manifold with mounted gauge pressure and absolute pressure transmitters 118 (4.65) 84 (3.31) 84 (3.31) 149 (5.87) 176 (6.93) 192 (7.56) 7MF9011-4EA valve manifold with mounted gauge pressure and absolute pressure transmitters, dimensions in mm (inch) 1/174 Siemens FI 01 · 2015 US Edition 158 (6.2) approx. 293 (11.54) 158 (6.2) approx. 285 (11.2) 1 approx. 150 (5.91) 190 (7.5) 7MF9011-4FA valve manifold with mounted gauge pressure and absolute pressure transmitters, dimensions in mm (inch) © Siemens AG 2015 Pressure Measurement Transmitters for general requirements SITRANS P DS III - Factory-mounting of valve manifolds on transmitters 7MF9411-5CA valve manifold with mounted differential pressure transmitter 192 (7.56) 7MF9411-5BA valve manifold with mounted differential pressure transmitter 244 (9.61) 215 (8.46) 190 (7.48) 7MF9411-5BA valve manifold with mounted differential pressure transmitter, dimensions in mm (inch) 245 (9.65) 256 (10.08) 7MF9411-5CA valve manifold with mounted differential pressure transmitter, dimensions in mm (inch) Siemens FI 01 · 2015 US Edition 1/175 1