Model CIP Ultra Sanitary Process Transmitter These CIP (Clean-In-Place) sanitary process transmitters are meet the environmental demands found in the applications listed manufactured in stainless steel and offer a variety of flanges, below in potential applications. electrical connections, and operating temperatures designed to FEATURES • 10 psig/a to 600 psig/a range • Track temperature changes, 93 °C/minute [200 °F/minute] • 4 mA to 20 mA output • 500 ms pressure response time • Secondary containment exceeds 1500 psi • Accuracy to 0.1 % • Intrinsically safe available (2N option only)9 • CE approved10 A 3 Complies to standard Model CIP PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range Code Available ranges Pressure ranges 38,1 mm [1.5 in] flange, 10 psi to 600 psi; 51 mm [2 in] flange, 10 psi to 500 psi; 63,5 mm [2.5 in] flange, 10 psi to 400 psi; 76 mm [3 in] flange, 10 psi to 250 psi AV 10 psi BJ 15 psi BL 25 psi 600 psi with 13MHHS clamp at 22 °C [72 °F], 38,1 mm [1.5 in] BN 50 psi Max. flange pressure BR 100 psi Response time (comb. mech. & elect.) 500 ms CL 200 psi CN 250 psi Resolution Infinite CQ 400 psi Orientation sensitivity 0.03 psi/G CR 500 psi CS 600 psi ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Process temperature -29 °C to 127 °C [-20 °F to 260 °F] Sensor temperature4 -1 °C to 82 °C [30 °F to 180 °F] Temperature effect, zero5 1 % full scale/38 °C [100 °F] (2 % full scale/38 °C [100 °F] for 1 psi) Temperature effect, span5 1 % full scale/38 °C [100 °F] (2 % full scale/38 °C [100 °F] for 1 psi) 2,3 ELECTRICAL SPECIFICATIONS OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Pressure ranges 10, 15, 25, 50, 100, 200, 250, 400, 500, 600 psi Temperature compensation -1 °C to 82 °C [30 °F to 180 °F] 1i. -54 °C to 121 °C [-65 °F to 250 °F] Internal amplifiers 2n(2N).Intrinsically safe amp 4 mA to 20 mA, two-wire current Characteristic Measure Supply voltage 13 Vdc to 32 Vdc Internal amplifier Special filtering enhancements Electrical connection (std) 1/2-14 NPT conduit exit with 1,5 m [5 ft] cable Pressure ports Tri-clover Load impedance (max.) 950 ohm @ 32 Vdc Zero balance 4 mA ± 0.16 mA Output (std) 4 mA to 20 mA, two-wire Electrical termination 6j. 1/2-14 NPT conduit fitting with 1,5 m [5 ft] of four conductor PVC cable 6a. Bendix PTIH-10-6P or equivalent 6 pin 6m. DIN 436508 6n. DIN 40050 Shunt calibration 3d. Remote buffered shunt calibration Special calibration Compound, vacuum, barometric Bar Wetted diaphragm 10c. Hastelloy C-276 Bridge resistance 12b. 5000 ohm (foil) (max. 121 °C [250 °F]) Zero and span adjustments 14b. Top access to pots MECHANICAL SPECIFICATIONS Characteristic Measure Media Steam, ethylene oxide, liquid, gas Wetted parts material 316-L stainless, Hastelloy C-276 Fill material NEOBEE M-20 Weight (nominal) 454 g [16 oz] Case material 316-L stainless Sanitary standard 3-A, #74-03 Over pressure 4X to max. flange pressure 2 Honeywell • Sensing and Control Ultra Sanitary Process Transmitter INTERNAL AMPLIFIERS Mounting dimensions and characteristics Amplifier specifications Intrinsically safe amp: Option 2n(2N)*** Output signal 4 mA to 20 mA Input power (voltage) 9 Vdc to 32 Vdc3 Input power (current) 4 mA to 20 mA Frequency response 2000 Hz Power supply rejection 60 dB Operating temperature -29 °C to 85 °C [-20 °F to 185 °F] Reverse voltage protection Yes Short circuit protection Yes Wiring code: connector A (+) Supply B No connection C No connection D (+) Output E Case ground F No connection Wiring code: cable (std)6,7 R (+) Supply Bl (+) Output W Case ground For reference only TYPICAL SYSTEM DIAGRAM *** See Honeywell’s Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.*** See Honeywell’s Web site for the most up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00. WIRING CODES Cable Two-wire current, 4 mA to 20 mA Red (+) Supply Black (+) Output (4 mA to 20 mA) White Case ground Flanges Code Size Flange 16b* 38,1 mm [1.5 in] Tri-clover 16c 51 mm [2 in] Tri-clover 16d 63,5 mm [2.5 in] Tri-clover 16e 76 mm [3 in] Tri-clover * Does not comply to 3A standards Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Honeywell • Sensing and Control 3 Model CIP Ultra Sanitary Process Transmitter NOTES 1. 2. 3. 4. 5. Accuracies stated are expected for best fit straight line for all errors, including linearity, hysteresis and non-repeatability. Higher ranges may be available for special applications. Consult factory. Specifications may vary with flange size and pressure range. Consult factory. -1 °C to 54 °C [30 °F to 130 °F] for 1 psi range (only applicable for CP100, CP101, CP200, and CP201). Temperature profile for heated vessels: Process temperature Sensor temperature 127 °C [260 °F] 82 °C [180 °F] 93 °C [200 °F] 63 °C [145 °F] 66 °C [150 °F] 49 °C [120 °F] 38 °C [100 °F] 32 °C [90 °F] 24 °C [75 °F] 24 °C [75 °F] 10 °C [50 °F] 18 °C [65 °F] -18 °C [0 °F] 4 °C [40 °F] -29 °C [-20 °F] -1 °C [30 °F] 6. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red; O=Orange. Color specifying cable and number or letter specifying connector. 7. No mating connector necessary with cable option. 8. For zero and span adjustment by instrumentation tech. Electrical termination is DIN 43650 Hirschmann plug; environmental class IP65 (NEMA 4). Conduit attachment by PG 9 thread on plug. 9. Range dependent; consult factory. 10. Termination dependent; consult factory. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to [email protected] WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008697-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.