Datasheet connectPower PROeco Single- and three-phase switched-mode power supply units NEW The new switch-mode power supply units of the PROeco series fit optimally in machine construction applications where space, ease of use and efficiency are top priorities. Direct parallel operation, a status relay and adjustable output voltage are basic features required for most every application. A visual display indicates the upper load limit from 90% and makes servicing and integrating the PROeco power supplies particularly easy. With an extremely low depth profile of only 100 mm, the supplies are ideal for use in the smallest of spaces, such as electrical cabinets and low profile distribution enclosures. The efficiency levels of up to 93% level is considerably higher than conventional power supplies in this class and, thanks to the associated reduced heat generation, use in small cabinets is easy. Features: • Slim design with extremely narrow housing depth of 100 mm • Wide operating temperature range: –25°C…+70°C • The output voltage can be precisely adjusted via a potentiometer on supply front • Remote monitoring via integrated status relay • Three-colored LED indicators for simple error detection • Advanced visual warning indication at 90% of rated output current • High efficiency of up to 93% on selected models • International approvals: CE, TÜV and cULus Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com connectPower PROeco PROeco power supplies with basic functionality and a high level of reliability •Single- and three-phase switchedmode power supply units •Slim design •Large temperature range from –25 °C to 70 °C •The output voltage can be precisely adjusted via the potentiometer on the front •Remote monitoring via integrated status relay •Three-colored LED indicators for simple error detection •Advanced visual warning at 90% rated output current • International approvals % Short-circuit protection Overload protection Overtemperature protection EMC / shock / vibration Noise emission acc. to EN55022 Noise immunity tests acc. to Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) Electrical equipment of machines Safety transformers for switched-mode power units Machinery with electronic equipment Safety extra-low voltage Protective separation / protection against electrical shock Protection against dangerous shock currents –25 °C…+70 °C / –40 °C…+85 °C 5 %…95 % RH IP 20 I, with PE connection 2 3 kV I/O / 2 kV I/earth / 0.5 kV O/earth > 500.000 h acc. to IEC 1709 (SN29500) yes, max. 5 without diode module metal, corrosion resistant horizontal on mounting rail TS 35, 50 mm spacing top and bottom for free air circulation, can be mounted side-by-side with 15 mm space between units. Yes, automatic restart Yes, IU characteristic curve Yes, automatic restart Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN61000-4-6 (conducted), EN61000-4-11 (Dips) Acc. to EN61000-3-2 1 g acc. to EN50178, shock: 15 g in all directions 80 60 40 20 0 –25 75 50 25 0 80 100 60 70 960 Watt 60 40 20 0 –25 0 20 30 40 50 Ambient temperature (°C) Voltage derating 90 80 70 50 60 70 60 100 40 60 80 190 20 20 30 40 50 Ambient temperature (°C) 100 VDE0100-410 / acc. to DIN57100-410 0 0 120 110 IU Characteristic curve 2 100 Acc. to EN60204 Acc. to EN61558-2-17 Acc. to EN50178 / VDE0160 SELV acc. to EN60950-1, PELV acc. to EN60204-1 Acc. to VDE0106-101 ≤ 480 Watt 120 Ioutput (% IN) Ambient temp. operating / storage temperature Max. perm. air humidity (operation) Degree of protection Class of protection Pollution degree Insulation voltage input/output MTBF Parallel connection option Housing version Mounting position, installation notice Derating curves Pout [% Pn] General data Ioutput (% IN) Technical Data \ 120 140 160 40 80 120 160 200 240 280 320 360 400 440 DC Input [V] connectPower PROeco PROeco PRO ECO 72W 24V 3A L (+) N (–) AC PE PRO ECO 120W 24V 5A DC + L (+) – – 13 14 N (–) AC PE + + – – 13 14 DC Pay attention to polarity of DC connection Pay attention to polarity of DC connection Technical Data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max Wire cross-section, flexible min/max Wire cross-section, AWG/kcmil Min./max. tightening torque range Stripping length Note Ordering Data Note mm² mm² min/max Nm mm 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 0.55 A @ 230 V AC / 1.04 A @ 110 V AC 0.22 A @ 370 V DC / 0.68 A @ 120 V DC Yes / max. 40 2 A / DI, Safety fuse 6 A, Char. B, Circuit breaker 2...4 A, Char. C, Circuit breaker 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 1.26 A @ 230 V AC / 2.24 A @ 110 V AC 0.39 A @ 370 V DC / 1.16 A @ 120 V DC Yes / max. 40 4 A / DI, Safety fuse 6 A, Char. B, Circuit breaker 3...5 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 3 A up to 55 °C 3 A @ 55 °C, 2.25 A @ 70 °C Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 5 A up to 55 °C 5 A @ 55 °C, 3.75 A @ 70 °C Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC Output voltage > 21.6 V DC / < 20.4 V DC > 87 % @ 230 V AC & 3 A 4 W / 9.5 W < 1 mA > 0.42 @ 230 V AC / > 0.45 @ 115 V AC > 100 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 34 / 100 mm / 0.5 kg > 87 % @ 230 V AC & 5 A 4 W / 15 W < 1 mA > 0.47 @ 230 V AC / > 0.56 @ 115 V AC > 80 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 40 / 100 mm / 0.6 kg CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 3 for L/N/PE 5 (13,14,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0.6 6 6 CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 3 for L/N/PE 6 (13,14,+,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0.6 6 6 Type PRO ECO 72W 24V 3A Type PRO ECO 120W 24V 5A Qty. 1 Part No. 1469470000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Part No. 1469480000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. 3 connectPower PROeco PROeco PRO ECO 240W 24V 10A L (+) N (–) AC PE PRO ECO 480W 24V 20A + + – – 13 14 DC L (+) N (–) AC PE + + – – – 13 14 DC Pay attention to polarity of DC connection Pay attention to polarity of DC connection Technical Data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max mm² Wire cross-section, flexible min/max mm² Wire cross-section, AWG/kcmil min/max Min./max. tightening torque range Nm Stripping length mm Note Ordering Data Note 4 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 1.23 A @ 230 V AC / 2.47 A @ 110 V AC 1.18 A @ 370 V DC / 2.4 A @ 120 V DC Yes / max. 15 A 4 A / DI, Safety fuse 10 A, Char. B, Circuit breaker 3...4 A, Char. C, Circuit breaker 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 2.37 A @ 230 V AC / 5.2 A @ 110 V AC 1.55 A @ 370 V DC / 4.65 A @ 120 V DC Yes / max. 3 A 6 A / DI, Safety fuse 16 A, Char. B, Circuit breaker 6…8 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 10 A up to 55 °C 10 A @ 55 °C, 7.5 A @ 70 °C Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 20 A up to 55 °C 20 A @ 55 °C, 15 A @ 70 °C Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC > 90 % @ 230 V AC & 10 A 3 W / 24 W < 1 mA > 0.93 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 5 125 / 60 / 100 mm / 1 kg > 91 % @ 230 V AC & 20 A 5 W / 43 W < 1 mA > 0.97 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 3 125 / 100 / 120 mm / 1.6 kg CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 3 for L/N/PE 6 (13,14,+,+, - -) 0.5/6 0.5/6 0.5/2.5 0.5/2.5 26/12 26/12 0.5/0.6 0.5/0..6 6 6 CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 3 for L/N/PE 7 (13,14,+,+, - ,-,-) 0.5/6 0.18/6 0.5/2.5 0.5/2.5 26/12 26/10 0.5/0.6 0.5/0.6 6 7 Type PRO ECO 240W 24V 10A Type PRO ECO 480W 24V 20A Qty. 1 Part No. 1469490000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Part No. 1469510000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. connectPower PROeco PROeco PRO ECO 960W 24V 40A L (+) N (–) AC PE + + – – – 13 14 DC Pay attention to polarity of DC connection Technical Data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max mm² Wire cross-section, flexible min/max mm² Wire cross-section, AWG/kcmil min/max Min./max. tightening torque range Nm Stripping length mm Note Ordering Data Note 100 … 240 V AC 85 … 264 V AC (Derating @ 100 V AC) 47 … 63 Hz 80 … 370 DC (Derating @ 120 V DC) 4.6 A @ 230 V AC / 9.9 A @ 110 V AC 2.9 A @ 370 V DC / 9 A @ 120 V DC Yes / max. 3 A 16 A / DI, Safety fuse 20 A, Char. B, Circuit breaker 16 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 40 A up to 50 °C 40 A @ 50 °C, 24 A @ 70 °C Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC > 93 % @ 230 V AC & 40 A 6 W / 76 W < 1 mA > 0.97 @ 230 V AC / > 0.99 @ 115 V AC > 20 ms @ 230 V AC / > 20 ms @ 115 V AC yes, max. 3 125 / 160 / 120 mm / 2.9 kg CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 3 for L/N/PE 7 (13,14,+,+,+, - -) 0.18/6 0.5/16 0.5/2.5 2.5/10 26/10 22/8 0.5/0.6 1.2/1.5 7 12 Type PRO ECO 960W 24V 40A Qty. 1 Part No. 1469520000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. 5 connectPower PROeco PROeco PRO ECO3 120W 24V 5A L1 (+) L2 (–) AC L3 PE PRO ECO3 240W 24V 10A + + – – 13 14 DC Pay attention to polarity of DC connection L1 (+) L2 (–) AC L3 PE + + – – 13 14 DC Pay attention to polarity of DC connection Technical Data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max mm² Wire cross-section, flexible min/max mm² Wire cross-section, AWG/kcmil min/max Min./max. tightening torque range Nm Stripping length mm Note Ordering Data Note 6 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 0.3 A @ 3 x 500 V AC / 0.4 A @ 3 x 400 V AC 0.2 A @ 800 V DC / 0.4 A @ 450 V DC Yes / max. 40 A 2 A / DI, Safety fuse 2...3 A, Char. C, Circuit breaker 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 0.6 A @ 3 x 500 V AC / 0.8 A @ 3 x 400 V AC 0.4 A @ 800 V DC / 0.7 A @ 450 V DC Yes / max. 50 A 2 A / DI, Safety fuse 2...3 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 5 A up to 55 °C 5 A @ 55 °C, 3.75 A @ 70 °C Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 10 A up to 55 °C 10 A @ 55 °C, 7.5 A @ 70 °C Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC 87 % @ 3 x 500 V AC / 88 % @ 3 x 400 V AC 6 W / 13 W < 1 mA > 0.4 @ 3 x 500 V AC / > 0.45 @ 3 x 400 V AC > 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 125 / 40 / 100 mm / 0.6 kg 88 % @ 3 x 500 V AC / 89 % @ 3 x 400 V AC 8 W / 26 W < 0.5 mA > 0.45 @ 3 x 500 V AC / > 0.5 @ 3 x 400 V AC > 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 5 125 / 60 / 100 mm / 1 kg CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 6 (13,14,+,+, - -) 0.18/6 0.5/6 0.5/2.5 0.5/2.5 26/10 26/12 0.5/0.6 0.5/0.6 8 6 CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 6 (13,14,+,+, - -) 0.18/6 0.5/6 0.5/2.5 0.5/2.5 26/10 26/12 0.5/0.6 0.5/0.6 7 6 Type PRO ECO3 120W 24V 5A Type Qty. 1 PRO ECO3 240W 24V 10A Qty. 1 Part No. 1469530000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Part No. 1469540000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. connectPower PROeco PROeco PRO ECO3 480W 24V 20A L1 (+) L2 (–) AC L3 PE PRO ECO3 960W 24V 40A + + – – – 13 14 DC Pay attention to polarity of DC connection L1 (+) L2 (–) AC L3 PE + + – – – 13 14 DC Pay attention to polarity of DC connection Technical Data Input Rated input voltage AC input voltage range AC frequency range DC input voltage range AC current consumption DC current consumption Input fuse (internal) / inrush current Recommended back-up fuse Output Rated output voltage Output voltage Ramp-up time / residual ripple, switching peaks Rated output current @ Urated Continuous output current @ 24 V DC Capacitive load Protection against reverse voltages from the load Protection against internal surge voltage Signalling DC OK Alarm Error Voltage monitoring / no-voltage contact / contact load On/Off relay General data Efficiency Power loss @ idling / nominal load Earth discharge current Power factor (approx.) Mains buffering @ Irated Parallel connection option Height x width x depth / weight Approvals Approvals Connection data Conductor connection system Number of terminals Wire cross-section, rigid min/max mm² Wire cross-section, flexible min/max mm² Wire cross-section, AWG/kcmil min/max Min./max. tightening torque range Nm Stripping length mm Note Ordering Data Note 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 1.2 A @ 3 x 500 V AC / 1.5 A @ 3 x 400 V AC 0.7 A @ 800 V DC / 1.2 A @ 450 V DC Yes / max. 50 A 4 A / DI, Safety fuse 3...5 A, Char. C, Circuit breaker 3 x 400...3 x 500 V AC (Wide-range input) 3 x 340...3 x 575 V AC / 2 x 360...2 x 575 V AC 47...63 Hz 450...800 V DC (max. 500 V DC in accordance with UL 508) 2.15 A @ 3 x 500 V AC / 2.68 A @ 3 x 400 V AC 1.37 A @ 800 V DC / 2.37 A @ 450 V DC Yes / max. 40 A 6 A / DI, Safety fuse 10 A, Char. B, Circuit breaker 6...8 A, Char. C, Circuit breaker 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 20 A up to 55 °C 20 A @ 55 °C, 15 A @ 70 °C Unrestricted 30…35 V DC 35 V DC 24 V DC ± 1 % 22...28 V DC (adjustable via potentiometer on front) < 100 ms / < 50 mVSS @ 24 V DC, IR 40 A up to 50 °C 40 A @ 50 °C, 24 A @ 70 °C Unrestricted 30…35 V DC 35 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC LED Green (Uoutput > 21.6 V DC) LED Yellow (Ioutput > 90 % IR ) LED Red (Overload, overtemperature, short-circuit, Uoutput < 20.4 V DC) Yes / NO contact / max. 30 V AC/DC 1 A Output voltage > 21.6 V DC / < 20.4 V DC 89 % @ 3 x 500 V AC / 90 % @ 3 x 400 V AC 8 W / 48 W < 0.5 mA > 0.41 @ 3 x 500 V AC / > 0.43 @ 3 x 400 V AC > 30 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 3 125 / 100 / 120 mm / 1.3 kg 90 % @ 3 x 500 V AC / 91 % @ 3 x 400 V AC 5 W / 95 W < 1 mA > 0.56 @ 3 x 500 V AC / > 0.56 @ 3 x 400 V AC > 25 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC yes, max. 3 125 / 160 / 120 mm / 2.5 kg CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 7 (13,14,+,+, - ,-,-) 0.18/6 0.18/6 0.5/2.5 0.5/2.5 26/10 26/10 0.5/0.6 0.5/0.6 7 7 CE, TÜV (EN/IEC 60950-1), cULus Input Output Screw connection Screw connection 4 for L1/L2/L3/PE 7 (13,14,+,+, - ,-,-) 0.18/6 0.5/16 0.5/2.5 2.5/10 26/10 22/8 0.5/0.6 1.2/1.5 7 12 Type PRO ECO3 480W 24V 20A Type PRO ECO3 960W 24V 40A Qty. 1 Part No. 1469550000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. Qty. 1 Part No. 1469560000 The internal varistor found in a switch-mode power unit does not replace the necessary surge protection in a system. 7 connectPower PROeco 8 Subject to technical changes • 04/14 • 1M • LIT1402