ACT20X Manual Revision History Version Date Change 0.0 02/2009 First Edition 1.0 12/2011 Further products complemented 2.0 02/2014 Updating of ATEX and IEC labeling Further products complemented Contact Address Weidmüller Interface GmbH & Co. KG PO Box 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Germany Phone Fax E-Mail Internet 1066540000/02/02.14 +49 (0) 5231 14-0 +49 (0) 5231 14-2083 [email protected] www.weidmueller.com 3 Contents Contents Revision History ............................................................................................................................................... 3 Contact Address ............................................................................................................................................... 3 Contents ............................................................................................................................. 4 1. Approvals............................................................................................................... 8 1.1 CE........................................................................................................................................................ 8 1.2 EMC..................................................................................................................................................... 8 1.3 LVD ..................................................................................................................................................... 8 1.4 UL ........................................................................................................................................................ 8 1.5 ATEX ................................................................................................................................................... 8 1.6 IECEx .................................................................................................................................................. 8 1.7 cFMus ................................................................................................................................................. 8 1.8 SIL ....................................................................................................................................................... 9 1.9 GOST .................................................................................................................................................. 9 1.10 DNV ..................................................................................................................................................... 9 2. Warranty Statement ............................................................................................ 10 2.1 36 Months Warranty ........................................................................................................................ 10 3. Safety Instructions .............................................................................................. 11 3.1 Approved Use .................................................................................................................................. 11 3.2 Qualified Personnel......................................................................................................................... 11 3.3 Accuracy of the Technical Documentation .................................................................................. 11 3.4 Liability ............................................................................................................................................. 11 3.5 Definitions ........................................................................................................................................ 11 3.6 Symbol Identification ...................................................................................................................... 12 3.7 Electrical Precautions ..................................................................................................................... 12 3.8 General Instructions ....................................................................................................................... 12 4. Introduction ......................................................................................................... 13 4.1 Product Description ........................................................................................................................ 13 5. 4 4.1.1 Product Family ACT20X ......................................................................................................... 13 4.1.2 General Description ................................................................................................................ 15 4.1.3 The Six Basic Module Types in Detail .................................................................................... 16 Installation ........................................................................................................... 17 1066540000/02/02.14 Contents 5.1 General ............................................................................................................................................. 17 5.1.1 Environment ............................................................................................................................ 17 5.2 Unpacking ........................................................................................................................................ 17 5.3 Mounting .......................................................................................................................................... 18 5.4 Marking ............................................................................................................................................. 18 5.5 Electrical Connections.................................................................................................................... 19 5.5.1 EMI Protection......................................................................................................................... 19 5.6 Calibration and Adjustment ........................................................................................................... 19 5.7 Release Lever .................................................................................................................................. 19 5.8 Encoding .......................................................................................................................................... 20 5.9 Configuration ................................................................................................................................... 21 6. Operation ............................................................................................................. 22 6.1 Normal Operation ............................................................................................................................ 22 6.2 Warm-Up .......................................................................................................................................... 22 6.3 Cleaning ........................................................................................................................................... 22 7. Product Installation / Operation ......................................................................... 23 7.1 ACT20X-HDI-SDO (NAMUR Pulse Isolator) .................................................................................. 23 7.2 7.3 7.4 7.1.1 Description .............................................................................................................................. 23 7.1.2 Status/Alarm LEDs .................................................................................................................. 24 7.1.3 Electrical Connections ............................................................................................................ 25 7.1.4 Function Description ............................................................................................................... 25 7.1.5 Specifications .......................................................................................................................... 25 ACT20X-HTI-SAO (Temperature/mA Converter) .......................................................................... 30 7.2.1 Description .............................................................................................................................. 30 7.2.2 Status/Alarm LEDs .................................................................................................................. 31 7.2.3 Electrical Connections ............................................................................................................ 32 7.2.4 Specifications .......................................................................................................................... 32 ACT20X-SDI-HDO (Solenoid/Alarm Driver) ................................................................................... 39 7.3.1 Description .............................................................................................................................. 39 7.3.2 Status/Alarm LEDs .................................................................................................................. 40 7.3.3 Electrical Connections ............................................................................................................ 41 7.3.4 Specifications .......................................................................................................................... 41 ACT20X-HUI-SAO (Universal Converter) ...................................................................................... 46 7.4.1 Description .............................................................................................................................. 46 7.4.2 Status/Alarm LEDs .................................................................................................................. 47 1066540000/02/02.14 5 Contents 7.5 7.6 7.7 7.8 7.4.3 Electrical Connections ............................................................................................................ 48 7.4.4 Specifications .......................................................................................................................... 48 ACT20X-HAI-SAO (HART-transparent Repeater) ......................................................................... 56 7.5.1 Description .............................................................................................................................. 56 7.5.2 Status/Alarm LEDs .................................................................................................................. 57 7.5.3 Electrical Connections ............................................................................................................ 58 7.5.4 Specifications .......................................................................................................................... 58 ACT20X-SAI-HAO (HART-transparent Driver) .............................................................................. 63 7.6.1 Description .............................................................................................................................. 63 7.6.2 Status/Alarm LEDs .................................................................................................................. 64 7.6.3 Electrical Connections ............................................................................................................ 65 7.6.4 Specifications .......................................................................................................................... 65 ACT20-FEED-IN-PRO-S ................................................................................................................... 70 7.7.1 Description .............................................................................................................................. 70 7.7.2 Status/Alarm LEDs .................................................................................................................. 71 7.7.3 Electrical connections ............................................................................................................. 72 7.7.4 Specifications .......................................................................................................................... 72 Female Plug BHZ 5.00 ..................................................................................................................... 76 7.8.1 Description .............................................................................................................................. 76 7.8.2 Specifications .......................................................................................................................... 77 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) ......................................79 ATEX Installation Drawing ...................................................................................................................... 79 IECEx Installation Drawing ..................................................................................................................... 83 FM Installation Drawing .......................................................................................................................... 87 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) ..............................91 ATEX Installation Drawing ...................................................................................................................... 91 IECEx Installation Drawing ..................................................................................................................... 97 FM Installation Drawing ........................................................................................................................ 103 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver).....................................109 ATEX Installation Drawing .................................................................................................................... 109 IECEx Installation Drawing ................................................................................................................... 115 FM Installation Drawing ........................................................................................................................ 121 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) ........................................127 ATEX Installation Drawing .................................................................................................................... 127 IECEx Installation Drawing ................................................................................................................... 137 FM Installation Drawing ........................................................................................................................ 147 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) ...........................157 6 1066540000/02/02.14 Contents ATEX Installation Drawing .................................................................................................................... 157 IECEx Installation Drawing ................................................................................................................... 167 FM Installation Drawing ........................................................................................................................ 177 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) ................................187 ATEX Installation Drawing .................................................................................................................... 187 IECEx Installation Drawing ................................................................................................................... 191 FM Installation Drawing ........................................................................................................................ 195 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) ................................199 ATEX Installation Drawing .................................................................................................................... 199 IECEx Installation Drawing ................................................................................................................... 203 FM Installation Drawing ........................................................................................................................ 207 1066540000/02/02.14 7 Approvals 1. Approvals 1.1 CE These products fulfill the guidelines issued by the European Union and are therefore entitled to carry the CE mark. DEKRA Certification B.V. II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I 1.6 IECEx In accordance with: - IEC 60079-0:2011 1.2 EMC In accordance with: - IEC 60079-11:2011 - IEC 60079-15:2010 - IEC 60079-26:2007 - EN 61326-1:2006 IECEx marking: Ex nA nC IIC T4 Gc 1.3 LVD In accordance with: - EN 61010-1:2010 1.4 UL In accordance with: - UL 61010-1 [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I 1.7 cFMus In accordance with: Canada - E60079-0 - CSA 22.2-157 - E60079-11 - CSA 22.2-213 - E60079-15 USA 1.5 ATEX In accordance with: - UL 60079-0 - FM3600 - UL 60079-11 - FM3610 - UL 60079-15 - FM3611 - FM3810 - EN 60079-0:2012 - EN 60079-11:2012 - EN 60079-15:2010 - EN 60079-26:2007 cFMus marking: Install in CL I DIV2 GP A-D T4 Provides IS circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4. ATEX marking: II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc 8 1066540000/02/02.14 Approvals 1.8 SIL 1.9 GOST 1066540000/02/02.14 1.10 DNV 9 Warranty Statement 2. Warranty Statement 2.1 36 Months Warranty Weidmüller gives a 36 months warranty on the product in accordance with the warranty terms as described in the general business conditions of the Weidmüller company which has sold the products to you. Weidmüller guarantees that defects which have already existed at the time when the risk passed will be repaired by Weidmüller free of charge or Weidmüller will provide a new, functionally equivalent product to replace the defective one. The warranty referred to above covers Weidmüller products. Unless otherwise expressly stated in this catalogue/product description, Weidmüller gives no warranty or guarantee as to the interoperability in specific systems or the fitness for any particular purpose. To the extent permitted by law, any claims for damages and reimbursement of expenses, based on whatever legal reason, including contract or tort, shall be excluded. Unless otherwise expressly stated in this warranty, the general business conditions and the expressive liability commitments therein of the respective Weidmüller company which has sold the products to you are applicable. 10 1066540000/02/02.14 Safety Instructions 3. Safety Instructions 3.1 Approved Use This product is intended for use in applications as described in the operating instructions only. Any other utilization is not permitted and can lead to accidents or destruction of the device. Using the device in non-approved applications will immediately void all guarantee and warranty claims on the part of the operator against the manufacturer. 3.2 Qualified Personnel These operating instructions are intended for trained and qualified personnel that is familiar with the valid regulations and standards relevant to the field of application. 3.3 3.4 Liability To the extent that instructions in this manual are not strictly observed, the customer cannot advance a demand against Weidmüller that would otherwise exist according to the concluded sales agreement. 3.5 Definitions • Hazardous voltages have been defined as the ranges: 75…1500 V DC and 50…1000 V AC. • Technicians are qualified persons trained to mount, operate and troubleshoot technically correct and in accordance with safety regulations. • Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation. Accuracy of the Technical Documentation These manual was written with due care and attention. However, unless otherwise required by law, we do not guarantee that the data, images and drawings are accurate or complete nor do we accept liability for their contents. Weidmüller’s general business conditions apply in their respective valid form. They are subject to alteration without notice. 1066540000/02/02.14 11 Safety Instructions 3.6 Symbol Identification 3.7 Electrical Precautions DANGER WARNING Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. High voltage! • Before removing or mounting the unit, turn off power supply. Follow ESD installation regulations, including EMI precautions. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. 3.8 General Instructions • Read and follow all instructions in this manual. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. NOTICE Indicates a situation that may result in material damage. The CE mark proves the compliance of the module with the essential requirements of the directives. • Inform yourself about hazards which can be caused by the product. • Observe the safety and accident prevention regulations. • Regularly check that all measures to prevent accidents are being complied with. • Only operate the product if it is in perfect technical condition, according to its intended use, in awareness of safety and risks and in adherence to the instructions in this manual. • Keep this manual and all other applicable documents complete, legible and accessible to personnel at all times. • Refrain from any procedures and actions that would expose personnel or third parties to any risk. Ex modules have been approved according to the ATEX directive for use in connection with installations in explosive areas. This symbol is combined with one of the signal words DANGER, WARNING or CAUTION to indicate a hazardous situation. The double insulation symbol shows that the device is protected by double or reinforced insulation.. 12 1066540000/02/02.14 Introduction 4. Introduction 4.1 Product Description 4.1.1 Product Family ACT20X Order No. Type Description Function 8965340000 ACT20X-HDI-SDO-RNO-S NAMUR pulse isolator – relay NO NAMUR in (from Ex) to relay out 8965350000 ACT20X-HDI-SDO-RNC-S NAMUR pulse isolator – relay NC NAMUR in (from Ex) to relay out 8965360000 ACT20X-HDI-SDO-S NAMUR pulse isolator NAMUR in (from Ex) to digital out 8965370000 ACT20X-2HDI-2SDO-RNO-S 2-channel NAMUR pulse isolator – relay NO 2x NAMUR in (from Ex) to 2x relays out 8965380000 ACT20X-2HDI-2SDO-RNC-S 2-channel NAMUR pulse isolator – relay NC 2x NAMUR in (from Ex) to 2x relays out 8965390000 ACT20X-2HDI-2SDO-S 2-channel NAMUR pulse isolator 2x NAMUR in (from Ex) to 2x digital out 8965400000 ACT20X-SDI-HDO-L-S Solenoid/alarm driver, L = low current max. 35 mA digital in to safe digital out (to Ex IIC) 8965410000 ACT20X-SDI-HDO-H-S Solenoid/alarm driver, H = high current max. 60 mA digital in to safe digital out (to Ex IIB) 8965420000 ACT20X-2SDI-2HDO-S 2-channel Solenoid/alarm driver, L = low current max. 35 mA 2x digital in to 2x safe digital out (to Ex) 8965430000 ACT20X-HAI-SAO-S HART-transparent repeater mA in (from Ex) to mA out with HART transparency 8965440000 ACT20X-2HAI-2SAO-S 2-channel HART-transparent repeater 2x mA in (from Ex) to 2x mA out with HART transparency 8965450000 ACT20X-SAI-HAO-S HART-transparent driver mA in to mA out (to Ex) with HART transparency 8965460000 ACT20X-2SAI-2HAO-S 2-channel HART-transparent driver 2x mA in to 2x mA out (to Ex) with HART transparency 8965470000 ACT20X-HTI-SAO-S Temperature/mA converter temperature in (from Ex) to mA out 8965480000 ACT20X-2HTI-2SAO-S 2-channel Temperature/mA converter 2x temperature in (from Ex) to 2x mA out 1066540000/02/02.14 13 Introduction 8965490000 Table 4-1: 14 ACT20X-HUI-SAO-S Universal converter universal analog in (from Ex) to analog (V / mA) + trip relay out Family ACT20X 1066540000/02/02.14 Introduction 4.1.2 General Description Weidmüller’s ACT20X – new signal converters for hazardous areas: Universal family of products covers the entire field of hazardous area applications with six different basic functions. With the introduction of its ACT20X modules Weidmüller is offering a completely new family of signal converters for hazardous area applications. With just 11 mm per channel these compactly designed modules require very little space in the electrical cabinet. All ACT20X converters can be configured via a PC utilizing the software "WIManager". This software is based on vendor-neutral FDT/DTM technology. The innovative modules are designed to be installed in safe or hazardous areas of Zone 2. The ACT20X family includes digital and analogue intrinsically safe converters that both isolate and convert signals from as well as into hazardous areas. The innovative signal converters process 2-wire HART, NAMUR, RTD, thermocouple or DC signals as well as digital signals with electrical connection to hazardous area Zone 0. All modules have 3-way separation and are optionally available with dual channel functionality. With high levels of insulation resistance, accuracy and thermal stability ACT20X modules provide a pure, disturbance free signal at all times. A relay-based error monitoring facility simplifies servicing. ACT20X modules can be utilized in temperatures from -20 °C to +60 °C without restrictions. They have all relevant international approvals such as ATEX, IECEx, FM – in other words, the modules are predestined for use in applications all over the world. simple, coded mating. The integrated release lever ensures the connection can be disconnected without damage when servicing is required. Devices from the ACT20X family have been designed to operate in an ambient temperature range of -20 °C to +60 °C – in other words in practically all fields of industry. The hinged and transparent front plate can easily be opened upwards. It has been designed for simple accommodation of device markers. Products from the ACT20X assortment are designed to be installed in Zone 2 / Division 2 or in nonhazardous areas; international approvals such as ATEX, IECEx and FM (Class I, Division 1 and 2) allow processing of signals from Zone 0 / Division 1. Put succinctly, the modules are suitable for use in applications across the globe. Utilizing the "WI-Manager" configuration software based on FDT technology (Field Device Tool) makes it possible to adapt all ACT20X products via a PC to meet different process application requirements. For this purpose Weidmüller provides the Device Type Manager (DTM), which can be executed in any FDTbased frame application. As well as fast and errorfree parameterization of individual devices DTMs make it possible to evaluate measurement and diagnostic data. In addition, it is possible to unambiguously identify a connected device via DTM. ACT20X modules are equipped with a cleverly designed connection technology that supports 1066540000/02/02.14 15 Introduction 4.1.3 The Six Basic Module Types in Detail NAMUR Pulse Isolator The pulse isolator ACT20X-HDI-SDO is a special signal isolator/converter for NAMUR sensor signals from within Ex Zone 0. Transistor or relay outputs are available on the output side. For the higher accuracy of thermo couple signals, the use of special cold junction terminals ACT20XCJC-HTI-S (PRT 11 = 1-channel, PRT 21 = 2channel) recommended Universal Converter Solenoid/Alarm Driver The universal isolator/converter ACT20X-HUI-SAO is a user configurable temperature and signal converter for Pt100, thermal and current (mA) inputs from within Ex Zone 0 as well as an output for nonhazardous area devices. The ACT20X-SDI-HDO is a solenoid/alarm driver for the control of solenoids, acoustic alarms and LEDs mounted in the hazardous area (Ex Zone 0). The ACT20X-HUI-SAO-S converts and isolates current, voltage, potentiometer and temperature sensor signals (mA, V, potentiometer, RTD and TC). Optionally one or two channel versions available. For the higher accuracy of thermocouple signals, the use of special cold junction terminal ACT20X-CJCHTI-S is recommended: 1160640000 ACT20X-CJC-HTI-S PRT 11 (1-chan.) A dual-channel version is optionally available. HART-Transparent Repeater The ACT20X-HAI-SAO-S current supply isolator is a HART-protocol, transparent isolator for analogue input signals from Exzone 0. The input may also operate as an active current loop (the loop current provided by the device). It provides an 4...20 mA current signal for the safe zone on the output side. Features • Full functionality interfacing with Zone 0 / Division 1 hazardous area inputs and outputs It is available in a single-channel or two-channel version. • Approvals include use for Zone 0 (IECEx, ATEX), Class I, Division 1 and 2 (FM). HART-Transparent Driver • Analogue and binary signal interfacing with measurement and control devices. The ACT20X-SAI-HAO-S is a HART-protocol, transparent current output isolator. A DC current input signal from the safe area will be galvanically separated and drives controlled field devices in Ex zone 0. Temperature, DC, resistance and potentiometer It is available in a single-channel or two-channel version. • Dual channel options – minimizes rail space and installation cost Temperature/mA Converter • HART-transparent signaling The devices of the ACT20X-HTI-SAO family transmit analog signals galvanic isolated from hazardous areas to the safe area. The input circuits are designed intrinsically safe. • Integral fault alarm The ACT20X-HTI-SAO converts and isolates current and temperature sensor signals (mA, RTD and TC). The two-channel version ACT20X-2HTI-2SAO can be used as a signal splitter for mA signals. 16 • inputs • Milliamp and relay/opto outputs • High quality, 3-port isolation • -20 to +60 °C ambient temperature • All modules configurable with FDT/DTM Software "WI-Manager" 1066540000/02/02.14 Installation 5. Installation DANGER 5.2 Risk of explosion! 1 Check on receipt that the product received corresponds to the one ordered. • For installation in Zone 2, install the module in an outer enclosure with IP protection of at least IP54. • Protection must be according to type of protection Ex-n or Ex-e. WARNING High voltage! • Before removing or mounting the unit, turn off power supply. NOTICE Material damage through ESD! • Only carry out the following procedures under ESD-safe conditions. 5.1 General This product should only be installed by technically qualified personnel with sufficient training in instrumentation and control engineering. Unpacking 2 Also make sure that installation instructions have been supplied. 3 Unpack the product carefully. • The use of stranded wires is not permitted for mains wiring except for wires fitted with cable ends. • Descriptions of input/output and supply connections are shown in the block diagram and on the side label. • The module is provided with field wiring terminals and must be supplied from a power supply having double/reinforced insulation. • A power switch must be easily accessible and close to the module. • The power switch must be marked with a label telling that it will switch off the voltage to the module. • Year of manufacture can be taken from the first two digits in the serial number. • Should there be any doubt as to the correct handling of the module, contact your local distributor. VDE 0105 Part 1 / DIN EN 50110-1 defines qualified personnel as electrically skilled workers, electronically instructed personnel or personnel meeting similar local standards. 5.1.1 Environment This product is designed for use either indoors (IP20) in a control panel, or in a weather-proof field enclosure. • Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock as well as rain and heavy moisture. • If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by ventilation. • Product must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. • Product is designed to be safe at least under an altitude of up to 2000 m. 1066540000/02/02.14 17 Installation, Mounting 5.3 Mounting The product is designed to be mounted onto a TS 35 DIN rail. 5.4 Marking A device marker is located below the upper set of terminals for costumer identification. It clips onto the rail via a spring-loaded mounting foot and can be removed via a spring release on the edge of the product near the mounting rail. Illustration 5-3: Illustration 5-1: Mounting, Step 1 Illustration 5-2: Mounting, Step 2 18 Marking 1 Device Marker 1066540000/02/02.14 Installation 5.5 Electrical Connections See section 7, "Product Installation / Operation” for further information. 5.6 Calibration and Adjustment • During calibration and adjustment, carry out the measuring and connection of external voltages according to the specifications in this manual. • Only use tools and instruments that are safe to use. 5.5.1 EMI Protection NOTICE Do not install input, output and power supply cables close to sources of electrical interference! 5.7 Release Lever The terminals are released with a release lever. For example, sources of electrical interference could include relays, contactors, motors and their controls, including thyristor drives and the cables which connect these devices. Avoid installing ACT20X cables in the same ducting as such cables. Local electrical installation practices must be followed. Illustration 5-4: Release Lever 1 Release lever See section 7.8, "Female Plug BHZ 5.00” for further information. 1066540000/02/02.14 19 Installation, Encoding 5.8 Encoding NOTICE Leaving the product connectors uncoded results in lack of interchanging protection. All connectors will be identically encoded. 2 Plug encoded connector onto pin header. Encoding element is transferred from connector to pin header. Encoding element remains in the pin header housing. • Create connector coding plan prior to first mating and encode connectors accordingly. • Perform encoding procedure for each new module. The product housing is equipped with an automatic encoding. This connector interchanging protection is initially encoded upon shipping and can be individually adjusted. 1 Use screw driver to turn adjusting dial of connector clockwise. Either dial has 4 encoding positions, resulting in 4² = 16 possible positions. Connector is encoded. Illustration 5-5: Encoding Connector Illustration 5-6: Encoding Positions 20 Illustration 5-7: Transfer Encoding Element See section 7.8, "Female Plug BHZ 5.00” for further information. 1066540000/02/02.14 Installation 5.9 Configuration DANGER 2 Connect the CBX200 USB jack, as shown in the illustration: Configuration must be performed in a safe area! Configuration is performed via a connector located behind the front flap. 1 Open the front flap, as shown in the illustration: Illustration 5-9: 1 2 3 CBX200 USB Connection Jack connection under front flap CBX200 with USB connection PC 3 See "WI-Manager" documentation for further information. Illustration 5-8: Opening Front Flap 1066540000/02/02.14 21 Operation, Normal Operation 6. Operation 6.1 Normal Operation Operators are only allowed to adjust and operate modules that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard and the module is easily accessible. 6.2 6.3 Cleaning 1 Power supply switched off. 2 Clean with cloth moistened with distilled water. Warm-Up The product is designed to start-up as soon as power is supplied. However a warm-up period of 15 minutes is required before it performs to the specifications above. When auxiliary power is switched on, for the first 200 ms the product will consume up to 200 mA. 22 1066540000/02/02.14 Product Installation / Operation 7. Product Installation / Operation 7.1 ACT20X-HDI-SDO (NAMUR Pulse Isolator) 7.1.1 Description The pulse isolator ACT20X-HDI-SDO is a special signal isolator/converter for NAMUR sensor signals from within Ex Zone 0. The product is able for an intrinsically safe operation of NAMUR sensors or for contacts with floating and resistance circuits. Transistor or relay outputs are available on the output side. A dual-channel version is optionally available. The following NAMUR pulse isolators are available: Order No. Type Description 8965340000 ACT20X-HDI-SDO-RNO-S NAMUR pulse isolator – relay NO 8965350000 ACT20X-HDI-SDO-RNC-S NAMUR pulse isolator – relay NC 8965360000 ACT20X-HDI-SDO-S NAMUR pulse isolator 8965370000 ACT20X-2HDI-2SDO-RNO-S 2-channel NAMUR pulse isolator – relay NO 8965380000 ACT20X-2HDI-2SDO-RNC-S 2-channel NAMUR pulse isolator – relay NC 8965390000 ACT20X-2HDI-2SDO-S 2-channel NAMUR pulse isolator 1066540000/02/02.14 23 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) 7.1.2 Status/Alarm LEDs Illustration 7-1: Status/Alarm LEDs Condition LED 1 Channel 1 Channel 2 LED 3 Output Status Relay (NC) LED 2 Output yellow ON energized OFF OFF energized red flashing OFF de-energized Channel 2 Channel 1 Device OK activated de-activated green flashing wire short/break activated de-activated green flashing wire short/break yellow ON energized OFF OFF energized red flashing OFF de-energized No supply OFF OFF OFF OFF OFF de-energized Device failure OFF red OFF red OFF de-energized Flashing: Table 7-1: 24 8% ON and 92% OFF __|¯|_______|¯|_______|¯|_______ Status/Alarm LEDs 1066540000/02/02.14 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) 7.1.3 Electrical Connections Terminal Function 11 SW Sense 12 NAMUR − 13 SW Supply 14 Connector Terminal Function 41 COM / 42 NO / NC / OPTO – 43 COM / NAMUR + 44 NO / NC / OPTO – 21 SW Sense 51 GND 22 NAMUR − 52 +24 V DC 23 SW Supply 53 NC 24 NAMUR + 54 COM Table 7-2: 7.1.4 Ex input channel 1 Ex input channel 2 / OPTO + / OPTO + Connector output channel 1 output channel 2 power supply status relay Electrical Connections Function Description (1) NAMUR sensor with cable error detection in case of cable disconnection or short circuit. (2) Mechanical switch with cable error detection in case of cable disconnection or short circuit, when series resistance (RS) and parallel resistance (RP) are mounted on the switch. (3) Mechanical switch with cable error detection in case of cable disconnection, when parallel resistance (RP) is mounted on the switch. (4) Mechanical switch without cable error detection. See illustration 7-2 "Functional Block Diagram" for further information. 7.1.5 Specifications Features • Configuration and monitoring via FDT/DTM-Software "WI-Manager". • Selection of direct or inverted function for each channel. • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • Extended self diagnostic: Monitoring of error events and cable breakage via the individual status relay. • LED indication for operation status and malfunction. • 3-way galvanic isolation between input, output and supply. 1066540000/02/02.14 25 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) Illustration 7-2: 26 Functional Block Diagram 1066540000/02/02.14 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) Illustration 7-3: Applications Input NAMUR / Mechanical Switch with Series and Parallel Resistance NAMUR sensor, according to EN 60947-5-6 Mechanical Switch, Series resistance (RS) nom. 750 Ω Mechanical Switch, Parallel resistance (RP) nom. 15 kΩ Frequency range 0…5 kHz Min. pulse length > 0.1 ms Resistance nom. 1 kΩ Trigger level, signal < 1.2 mA, > 2.1 mA Trigger level, cable fault < 0.1 mA, > 6.5 mA 1066540000/02/02.14 27 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) Status Relay Safe Area Zone 2 Installation Voltage max. 125 V AC / 110 V 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Relay Output Safe Area Zone 2 Installation Voltage max. 250 V AC / 30 V 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 16 VA / 60 W Max. switching frequency 20 Hz Opto NPN Output Max. switching frequency 5 kHz Min. pulse length 60 μs Max. load, current / voltage 80 mA / 30 V DC Voltage drop at 80 mA < 2.5 V DC Power Supply Supply voltage 19.2…31.2 V DC NAMUR supply 8 V DC / 8 mA Max. consumption (2-channels) ≤3W Fuse 400 mA / 250 V AC Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Output 1 to output 2 1.5 kV AC / 150 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Specifications range -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % Calibration temperature +20…28 °C 28 1066540000/02/02.14 Product Installation / Operation, ACT20X-HDI-SDO (NAMUR Pulse Isolator) General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm Vibration IEC 60068-2-6, test Fc, 1g, 2…100 Hz Vibration, continuous IEC 60068-2-64, test Fh, 1g, 3…100 Hz Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² Response time for cable fault < 200 ms Default Settings Channel 1 function direct Channel 2 function direct Short circuit indication yes Breakage indication yes 1066540000/02/02.14 29 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) 7.2 ACT20X-HTI-SAO (Temperature/mA Converter) 7.2.1 Description The modules of the ACT20X-HTI-SAO family transmit analog signals galvanic isolated from hazardous areas to the safe area. The input circuits are designed intrinsically safe. The ACT20X-HTI-SAO converts and isolates current and temperature sensor signals (mA, RTD and TC). The two-channel version ACT20X-2HTI-2SAO can be used as a signal splitter for mA signals. For the higher accuracy of thermo couple signals, the use of special cold junction terminals ACT20X-CJCHTI-S recommended: 1160640000 ACT20X-CJC-HTI-S PRT 11 (1-channel) 1160650000 ACT20X-CJC-HTI-S PRT 21 (2-channel) The following converter types are available: Order No. Type Description 8965470000 ACT20X-HTI-SAO-S Temperature/mA converter 8965480000 ACT20X-2HTI-2SAO-S 2-channel temperature/mA converter 30 1066540000/02/02.14 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) 7.2.2 Status/Alarm LEDs Illustration 7-4: Status/Alarm LEDs Condition LED 1 Channel 1 Channel 2 LED 3 Output Status Relay (NC) LED 2 Output OFF ON energized red fault state energized red flashing fault state de-energized Channel 2 Channel 1 Device OK defective green flashing wire short/break OK defective green flashing wire short/break OFF ON energized red fault state energized red flashing fault state de-energized No supply OFF OFF OFF OFF OFF de-energized Device failure OFF red OFF red OFF de-energized Flashing: Table 7-3: 8% ON and 92% OFF __|¯|_______|¯|_______|¯|_______ Status/Alarm LEDs 1066540000/02/02.14 31 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) 7.2.3 Electrical Connections Function Terminal RTD Connector mA 2W 11 4W Sense– Sense– + 41 Out − – 42 Out + 43 Out − 44 Out + 51 GND 52 +24 V DC 53 NC 54 COM – R R– R– 13 + R R+ R+ 14 Ex input channel 1 Sense+ 21 Sense– Sense– + – 22 – R R– R– 23 + R R+ R+ 24 7.2.4 Function 3W 12 Ex input channel 2 Sense+ Table 7-4: Terminal Connector TC output channel 1 output channel 2 power supply status relay Electrical Connections Specifications Features • Configuration and monitoring are performed via FDT/DTM Software "WI-Manager". • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • The passive signal inputs for RTD, TC and mA are made for one or two channels and completely electrically isolated. • The two-channel version is suitable to use as a signal splitter. • 3-way galvanic isolation between input, output and supply. • Front LEDs indicate operation status and malfunction. • The cold junction compensation for TC-signal inputs is either the internal cold junction compensation, or for higher accuracy is an external cold junction compensation terminal available –- 1 channel 1160640000 ACT20X-CJC-HTI-S PRT 11 or 2 channel 1160650000 ACT20X-CJC-HTI-S PRT 21. • Extended self diagnostic: Monitoring of error events and cable breakage via the individual status relay. 32 1066540000/02/02.14 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-5: Functional Block Diagram 1066540000/02/02.14 33 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-6: Applications RTD Input Pt100, according to -200…+850 °C, IEC 60751 Ni100, according to -60…+250 °C, DIN 43760 Sensor types (* = without short circuit detection) Pt10*, Pt20*, Pt50*, Pt100, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Cable resistance per wire (max.) 50 Ω Sensor current nom. 0.2 mA Effect of sensor cable resistance (3/4-wire) < 0.002 Ω Sensor error detection (programmable) ON/OFF 34 1066540000/02/02.14 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) Sensor error current: when detecting else < 2 μA 0 μA TC Input, Sensor Types Temperature Range Standard B 0…+1820 °C IEC 60584-1 E -100…+1000 °C IEC 60584-1 J -100…+1200 °C IEC 60584-1 K -180…+1372 °C IEC 60584-1 L -200…+900 °C DIN 43710 N -180…+1300 °C IEC 60584-1 R -50…+1760 °C IEC 60584-1 S -50…+1760 °C IEC 60584-1 T -200…+400 °C IEC 60584-1 U -200…+600 °C DIN 43710 W3 0…+2300 °C ASTM E988-90 W5 0…+2300 °C ASTM E988-90 LR -200…+800 °C GOST 3044-84 Accuracy, General Values Absolute Accuracy Temperature Coefficient All ≤ ±0.1 % of span ≤ ±0.01 % of span / °C Accuracy, Basic Values Absolute Accuracy Temperature Coefficient mA ≤ ±16 μA ≤ ±1.6 μA / °C Pt100, Pt200, Pt1000 ≤ ±0.2 °C ≤ ±0.02 C / °C Pt500, Ni100, Ni120, Ni1000 ≤ ±0.3 °C ≤ ±0.03 C / °C Pt50, Pt400, Ni50 ≤ ±0.4 °C ≤ ±0.04 C / °C Pt250, Pt300 ≤ ±0.6 °C ≤ ±0.06 C / °C Pt20 ≤ ±0.8 °C ≤ ±0.08 C / °C Pt10 ≤ ±1.4 °C ≤ ±0.14 C / °C TC type: E, J, K, L, N, T, U ≤ ±1 °C ≤ ±0.1 C / °C TC type: R, S, W3, W5, LR ≤ ±2 °C ≤ ±0.2 C / °C TC type: B (160…400 °C) ≤ ±4.5 °C ≤ ±0.45 C / °C TC type: B (400…1820 °C) ≤ ±2 °C ≤ ±0.2 C / °C 1066540000/02/02.14 35 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) TC Input, Cold Junction Compensation (CJC) CJC: external with ACT20X-CJC-HTI (1160640000 or 1160650000) +20…+28 °C ≤ ±1 °C -20…+20 °C and +28…+60 °C≤ ±1.6 °C CJC via internal sensor ∆t = internal temperature – ambient temperature ±(2.0 °C + 0.2 °C * ∆t) Sensor error detection (programmable, only wire breakage) ON/OFF Sensor error current: when detecting else nom. 2 μA 0 μA Current Input Measurement range 0…20 mA Programmable measurement ranges 0…20 / 4…20 mA Input resistance nom. 20 Ω + PTC 50 Ω Sensor error detection (programmable) ON/OFF Current Output Programmable signal ranges 0…20 mA / 4…20 mA / 20…0 mA / 20…4 mA Load max. 4 mA / 600 Ω / 12 V DC Load stability ≤ ±0.01 % of span / 100 Ω Sensor error detection 0 / 3.5 mA / 23 mA / none Output limitation: on 4…20 and 20…4 mA signals on 0…20 and 20…0 mA signals 3.8…20.5 mA 0…20.5 mA Current limit ≤ 28 mA 2-wire 4…20 mA Loop Powered Output Signal range 4…20 mA Load resistance ≤ (Vsupply – 3.5 V) / 0.023 A [Ω] Load stability ≤ 0.01 % of span / 100 Ω Max. external 2-wire supply 3.5…26 V DC Effect of external 2-wire supply voltage variation < 0.005 % of span / V 36 1066540000/02/02.14 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) Status Relay Safe Area Zone 2 Installation Voltage max. 125 V AC / 110 V 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Power Supply Supply voltage 19.2…31.2 V DC Max. consumption (2-channels) ≤ 3.5 W Fuse 1.25 A / 250 V AC Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Output 1 to output 2 1.5 kV AC / 150 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Ambient temperature -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % Calibration temperature +20…28 °C General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm Vibration IEC 60068-2-6, test Fc, 1g, 2…100 Hz Vibration, continuous IEC 60068-2-64, test Fh, 1g, 3…100 Hz Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² EMC immunity influence ≤ ±0.5 % of span Extended EMC immunity: NAMUR NE 21, A criterion, burst ≤ ±1 % of span Signal/Noise ratio min. 60 dB (0…100 kHz) 1066540000/02/02.14 37 Product Installation / Operation, ACT20X-HTI-SAO (Temperature/mA Converter) Average response time incl. delay: Temperature input mA input ≤1s ≤ 0.4 s Default Settings Input type Temperature Connection type 3-wire Temperature unit °C Temperature sensor type Pt100 Temperature range 0…150°C Output current range 0…20 mA Output current on error 0…23 mA Analog output response time (1/10 s) 1s 38 1066540000/02/02.14 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) 7.3 ACT20X-SDI-HDO (Solenoid/Alarm Driver) 7.3.1 Description The ACT20X-SDI-HDO is a solenoid/alarm driver for the control of solenoids, acoustic alarms and LEDs mounted in the hazardous area (Ex Zone 0). Optionally one or two channel versions available. The following solenoid/alarm drivers are available: Order No. Type Description 8965400000 ACT20X-SDI-HDO-L-S Solenoid/alarm driver, L = low current max. 35 mA 8965410000 ACT20X-SDI-HDO-H-S Solenoid/alarm driver, H = high current max. 60 mA 8965420000 ACT20X-2SDI-2HDO-S 2-channel solenoid/alarm driver, L = low current max. 35 mA 1066540000/02/02.14 39 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) 7.3.2 Status/Alarm LEDs Illustration 7-7: Status/Alarm LEDs Condition LED 1 Channel 1 Channel 2 LED 3 Output Status Relay (NC) LED 2 Output yellow ON energized OFF OFF energized Channel 2 Channel 1 Device OK activated green flashing de-activated activated yellow ON energized OFF OFF energized green flashing de-activated No supply OFF OFF OFF OFF OFF de-energized Device failure OFF red OFF red OFF de-energized Flashing: Table 7-5: 40 8% ON and 92% OFF __|¯|_______|¯|_______|¯|_______ Status/Alarm LEDs 1066540000/02/02.14 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) 7.3.3 Electrical Connections Terminal Function 11 GND 12 Ex 1 13 Ex 2 14 Terminal Function 41 In − 42 In + 43 In − Ex 3 44 In + 21 GND 51 GND 22 Ex 1 52 +24 V DC 23 Ex 2 53 COM 24 Ex 3 54 NC Table 7-6: 7.3.4 Connector Ex output channel 1 Ex output channel 2 Connector input channel 1 input channel 2 power supply status relay Electrical Connections Specifications Features • Solenoid/alarm driver for the control of solenoids, acoustic alarms and LEDs installed in the hazardous area. • Two hardware versions make it possible to choose either low (35 mA) or high (60 mA) current output with 1-channel or 2-channel versions. • Configuration and monitoring via FDT/DTM-Software "WI-Manager". • Selection of direct or inverted function for each channel and the possibility of reducing the output current to the hazardous area to suit the application. • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • Extended self diagnostic: Monitoring of error events via the individual status relay. • LED indication: green and 2 yellow/red front LEDs to indicate operation status and malfunction. • 3-way galvanic isolation between input, output and supply, 2.6 kV AC. 1066540000/02/02.14 41 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) Illustration 7-8: 42 Functional Block Diagram 1066540000/02/02.14 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) Illustration 7-9: Applications NPN Input (NPN and mechanical switch) Trigger level (low) ≤ 2 V DC Trigger level (high) ≥ 4 V DC Max. external voltage 28 V DC Input impedance 3.5 kΩ PNP Input Trigger level (low) ≤ 8 V DC Trigger level (high) ≥ 10 V DC 1066540000/02/02.14 43 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) Max. external voltage 28 V DC Input impedance 3.5 kΩ Output Output ripple ACT20X-SDI-HDO-L-S, ACT20X-2SDI-HDO-S, low current (< 35 mA), Ex barrier data channel 1 < 40 mV RMS Vout no load Vout with load Iout max. 11–12 min. 24 V min. 12.5 V 35 mA 11–13 min. 24 V min. 13.5 V 35 mA 11–14 min. 24 V min. 14.5 V 35 mA Vout no load Vout with load Iout max. 21–22 min. 24 V min. 12.5 V 35 mA 21–23 min. 24 V min. 13.5 V 35 mA 21–24 min. 24 V min. 14.5 V 35 mA ACT20X-2SDI-HDO-S, low current (< 35 mA), Ex barrier data channel 2 ACT20X-SDI-HDO-H-S, high current (< 60 mA), Ex barrier data channel 1 11–12 11–13 11–14 Vout no load Vout with load Iout max. min. 9 V 60 mA min. 11.5 V 50 mA min. 10 V 60 mA min. 12.5 V 50 mA min. 11 V 60 mA min. 13.5 V 50 mA min. 24 V min. 24 V min. 24 V Status Relay Safe area Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 AC / 0.1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 44 1066540000/02/02.14 Product Installation / Operation, ACT20X-SDI-HDO (Solenoid/Alarm Driver) Power Supply Supply voltage 19.2…31.2 V DC Max. consumption (2-channels) ≤ 3.5 W Fuse 1.25 A / 250 V AC EMC immunity influence < ±0.5 % of span Extended EMC immunity: NAMUR NE 21, A criterion, burst < ±1 % of span Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Output 1 to output 2 1.5 kV AC / 150 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Ambient temperature -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % Calibration temperature +20…28 °C General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² Default Settings Channel 1 function Direct Channel 2 function Direct 1066540000/02/02.14 45 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) 7.4 ACT20X-HUI-SAO (Universal Converter) 7.4.1 Description The device ACT20X-HUI-SAO-S transmits analog signals from hazardous areas safely galvanically separated into non or less hazardous areas. The input circuits are designed intrinsically safe. The ACT20X-HUI-SAO-S converts and isolates current, voltage, potentiometer and temperature sensor signals (mA, V, potentiometer, RTD and TC). For the higher accuracy of thermocouple signals, the use of special cold junction terminal ACT20X-CJC-HTIS is recommended: 1160640000 ACT20X-CJC-HTI-S PRT 11 (1-Kanal) The following converter type is available: Order No. Type Description 8965490000 ACT20X-HUI-SAO-S Universal converter 46 1066540000/02/02.14 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) 7.4.2 Status/Alarm LEDs Illustration 7-10: Status/Alarm LEDs Condition LED 1 LED 2 Output Analog Output Relay LED 3 (Error) Status Relay (NC) 1) active 1) OFF energized 1) fault state 1) red flashing energized 1) fault state 1) red flashing energized Device/Signal OK OK and wire short/break de-activated and wire short/break green flashing Output relay activated green flashing yellow energized OFF de-energized No supply OFF OFF OFF de-energized OFF de-energized Device failure OFF red OFF de-energized red de-energized de-activated Flashing: 8% ON and 92% OFF 1) depends on configuration Table 7-7: __|¯|_______|¯|_______|¯|_______ Status/Alarm LEDs 1066540000/02/02.14 47 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) 7.4.3 Electrical Connections Function Terminal Terminal Function 41 Out − M3 42 Out + 2W /3W / 4W M1 43 COM 4W M2 44 NO 51 +24 V DC 52 GND 53 NC 54 COM TC RTD 11 + 3W / 4W 12 – / CJC 2W / 3W / 4W 13 CJC POT V mA mA Loop Connector output 14 21 – 22 + 23 – + 24 + Table 7-8: 7.4.4 – output relay power supply status relay Electrical Connections Specifications Features • Configuration and monitoring via FDT/DTM-Software "WI-Manager". • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • The active or passive signal inputs for RTD, TC, potentiometer, V and mA are completely electrically isolated. • The device detects automatically whether an active or passive current signal is connected. • The cold junction compensation for TC-signal inputs is either the internal cold junction compensation, or for higher accuracy is an external cold junction compensation terminal available –- 1 channel 1160640000 ACT20X-CJC-HTI-S PRT 11. • Extended self diagnostic: Monitoring of error events (e.g. cable breakage) via status relay. • Front LEDs indicates operation status and malfunction. • 3-way galvanic isolation between input, output and power supply. 48 1066540000/02/02.14 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) Illustration 7-11: Functional Block Diagram 1066540000/02/02.14 49 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) Illustration 7-12: Applications RTD, Resistance and Potentiometer Input Pt100, according to -200…+850 °C, IEC 60751 Ni100, according to -60…+250 °C, DIN 43760 Resistance (without short circuit detection in the range R = 0…18Ω, appr.) 0…10 kΩ Potentiometer 10 Ω…10 kΩ Sensor types (* = without short circuit detection) Pt10*, Pt20*, Pt50*, Pt100, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Cable resistance per wire (max.) 50 Ω Sensor current nom. 0.2 mA Effect of sensor cable resistance (3/4-wire) < 0.002 Ω 50 1066540000/02/02.14 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) Sensor error detection (programmable) ON/OFF Short circuit detection, RTD Yes TC Input, Sensor Types Temperature Range Standard B 0…+1820 °C IEC 60584-1 E -100…+1000 °C IEC 60584-1 J -100…+1200 °C IEC 60584-1 K -180…+1372 °C IEC 60584-1 L -200…+900 °C DIN 43710 N -180…+1300 °C IEC 60584-1 R -50…+1760 °C IEC 60584-1 S -50…+1760 °C IEC 60584-1 T -200…+400 °C IEC 60584-1 U -200…+600 °C DIN 43710 W3 0…+2300 °C ASTM E988-90 W5 0…+2300 °C ASTM E988-90 LR -200…+800 °C GOST 3044-84 Accuracy, General Values Absolute Accuracy Temperature Coefficient All ≤ ±0.1 % of span ≤ ±0.01 % of span / °C Accuracy, Basic Values Absolute Accuracy Temperature Coefficient mA ≤ ±16 μA ≤ ±1.6 μA / °C Volt ≤ ±20 μV ≤ ±2 μV / °C Pt100, Pt200, Pt1000 ≤ ±0.2 °C ≤ ±0.02 C / °C Pt500, Ni100, Ni120, Ni1000 ≤ ±0.3 °C ≤ ±0.03 C / °C Pt50, Pt400, Ni50 ≤ ±0.4 °C ≤ ±0.04 C / °C Pt250, Pt300 ≤ ±0.6 °C ≤ ±0.06 C / °C Pt20 ≤ ±0.8 °C ≤ ±0.08 C / °C Pt10 ≤ ±1.4 °C ≤ ±0.14 C / °C TC type: E, J, K, L, N, T, U ≤ ±1 °C ≤ ±0.1 C / °C TC type: R, S, W3, W5, LR ≤ ±2 °C ≤ ±0.2 C / °C TC type: B (160…400 °C) ≤ ±4.5 °C ≤ ±0.45 C / °C TC type: B (400…1820 °C) ≤ ±2 °C ≤ ±0.2 C / °C 1066540000/02/02.14 51 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) TC Input, Cold Junction Compensation (CJC) CJC: external with ACT20X-CJC-HTI (1160640000) +20…+28 °C ≤ ±1 °C -20…+20 °C and +28…+60 °C ≤ ±1.6 °C CJC via internal sensor ∆t = internal temperature – ambient temperature ±(2.0 °C + 0.4 °C * ∆t) Sensor error detection (programmable, only wire breakage) ON/OFF Sensor error current: when detecting else nom. 2 μA 0 μA Current Input Measurement range 0…20 mA Programmable measurement ranges 0…20 and 4…20 mA Input resistance nom. 20 Ω + PTC 50 Ω Sensor error detection: loop break (only when input is selected as 4…20 mA) Yes Voltage Input Measurement range 0…12 V DC Programmable measurement ranges 0…1 V / 0.2…1 V / 0…5 V / 1…5 V / 0…10 V / 2…10 V Input resistance nom. > 10 MΩ Current Output Signal range (span) 0…23 mA Programmable signal ranges 0…20 mA / 4…20 mA / 20…0 mA / 20…4 mA Load max. 4 mA / 600 Ω / 12 V DC Load stability ≤ 0.01 % of span / 100 Ω Sensor error detection 0 / 3.5 mA / 23 mA / none NAMUR NE 43, Upscale / Downscale 23 mA / 3.5 mA Output limitation: on 4…20 and 20…4 mA signals on 0…20 and 20…0 mA signals 3.8…20.5 mA 0…20.5 mA Current limit ≤ 28 mA 52 1066540000/02/02.14 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) 2-wire 4…20 mA Output Signal range 4…20 mA Load resistance ≤ (Vsupply – 3.5 V) / 0.023 A [Ω] Load stability ≤ 0.01 % of span / 100 Ω Max. external 2-wire supply 3.5…26 V DC Effect of external 2-wire supply voltage variation < 0.005 % of span / V Relay Output Safe Area Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Relay functions Setpoint, Window, Sensor error, Power and Off Hysteresis in % / display counts 0.1…25 % / 1…2999 On and Off delay 0…3600 s Sensor error detection Break / Make / Hold Status Relay Safe Area Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0,5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Power Supply Supply voltage 19.2…31.2 V DC Max. consumption ≤ 3.5 W Fuse 1.25 A / 250 V AC Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Ambient temperature -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % 1066540000/02/02.14 53 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) Calibration temperature +20…28 °C General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm Vibration IEC 60068-2-6, test Fc, 1g, 2…100 Hz Vibration, continuous IEC 60068-2-64, test Fh, 1g, 3…100 Hz Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² EMC immunity influence ≤ ±0.5 % of span Extended EMC immunity: NAMUR NE 21, A criterion, burst ≤ ±1 % of span Signal/Noise ratio min. 60 dB (0…100 kHz) Response time (0…90 %, 100…10 %): Temperature input, programmable mA / V input, programmable 1…60 s 0.4…60 s Default Settings Input type Temperature Connection type 3-wire Temperature unit °C Temperature sensor type Pt100 Temperature range 0…150 °C Output current range 0…20 mA Output current on error 23 mA Analog output response time (1/10 s) 1s Relay Software Parameters / Default Settings Function SETPOINT Contact function Normally Open (NO) Setpoint 50 °C (input type temperature) / 50 % Activation direction Increasing Hysteresis 1 °C (input type temperature) / 1 % 54 1066540000/02/02.14 Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter) Action on error Relay OPEN Activation delay 0s Deactivation delay 0s Illustration 7-13: Graphic depiction of window Illustration 7-14: Graphic depiction of setpoint 1066540000/02/02.14 55 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) 7.5 ACT20X-HAI-SAO (HART-transparent Repeater) 7.5.1 Description The ACT20X-HAI-SAO-S current supply isolator is a HART-protocol, transparent isolator for analogue input signals from Ex Zone 0. The input may also operate as an active current loop (the loop current provided by the device). It provides an 4...20 mA current signal for the safe zone on the output side. It is available in a single-channel or two-channel version. The following HART-transparent repeaters are available: Order No. Type Description 8965430000 ACT20X-HAI-SAO-S HART-transparent repeater 8965440000 ACT20X-2HAI-2SAO-S 2-channel HART-transparent repeater 56 1066540000/02/02.14 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) 7.5.2 Status/Alarm LEDs Illustration 7-15: Status/Alarm LEDs Condition LED 1 Channel 1 Channel 2 LED 3 Output Status Relay (NC) LED 2 Output activated OFF active energized defective red inactive de-energized red flashing inactive de-energized red blinking inactive de-energized Channel 1 Device OK signal limit exceeded green flashing Channel 2 fixed loop break limit exceeded activated OFF active energized defective red inactive de-energized red flashing inactive de-energized red blinking inactive de-energized signal limit exceeded green flashing fixed loop break limit exceeded No supply OFF OFF OFF OFF OFF de-energized Device failure OFF red OFF red OFF de-energized Blinking: 50% ON and 50% OFF __|¯¯¯¯|____|¯¯¯¯|____|¯¯¯¯|____ Flashing: 8% ON and 92% OFF __|¯|_______|¯|_______|¯|_______ Table 7-9: Status/Alarm LEDs 1066540000/02/02.14 57 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) 7.5.3 Electrical Connections Terminal Function 11 I Passive − 12 I Passive + 13 I Active Return 14 Terminal Function 41 Out − 42 Out + 43 Out − I Active Supply 44 Out + 21 I Passive − 51 GND 22 I Passive + 52 +24 V DC 23 I Active Return 53 NC 24 I Active Supply 54 COM Table 7-10: 7.5.4 Connector Ex input channel 1 Ex input channel 2 Connector output channel 1 output channel 2 power supply status relay Electrical Connections Specifications Features • HART-compatible for 0.5...2.5 kHz • Configuration and monitoring via FDT/DTM-Software "WI-Manager". • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • The active or passive mA current signal inputs are completely electrically isolated. • The device detects automatically whether an active or passive current signal is connected. • The two-channel device can be used as a signal splitter. • Extended self diagnostic: Monitoring of error events (e.g. cable breakage) via status relay. • Front LEDs indicates operation status and malfunction. • 3-way galvanic isolation between input, output and power supply. 58 1066540000/02/02.14 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-16: Functional Block Diagram 1066540000/02/02.14 59 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-17: Applications Current Input Measurement range 3.5…23 mA Alarm setpoint, low/high limit (programmable) 0…28 mA Sensor error detection < 1 mA Current Output Signal range (programmable) 3.5…23 mA Load max. 20 mA / 600 Ω / 12 V DC Load stability ≤ 0.01 % of span /100 Ω Sensor error detection (programmable) 3.5 mA / 23 mA / none 60 1066540000/02/02.14 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) Current limit ≤ 28 mA Effect of supply voltage change < ±10 μA 2-wire 4…20 mA Current Loop Output Signal range 3.5...23 mA Load resistance ≤ (Vsupply – 3.5 V) / 0.023 A [Ω] Load stability ≤ 0.01 % of span/100 Ω External 2-wire supply voltage 3.5…26 V DC Effect of external 2-wire supply voltage change < 0.005 % of span / V Accuracy Absolute Accuracy Temperature Coefficient General values ≤ ±0.1 % of span ≤ ±0.01 % of span / °C Basic values ≤ ±16 µA ≤ ±1.6 µA / °C Status Relay Safe Area Zone 2 Installation Voltage max. 125 V AC / 110 V 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Power Supply Supply voltage 19.2…31.2 V DC Max. consumption (2-channels) ≤3W Fuse 1.25 A / 250 V AC Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Output 1 to output 2 1.5 kV AC / 150 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Specifications range -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % Calibration temperature +20…28 °C 1066540000/02/02.14 61 Product Installation / Operation, ACT20X-HAI-SAO (HART-transparent Repeater) General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm Vibration IEC 60068-2-6, test Fc, 1g, 2…100 Hz Vibration, continuous IEC 60068-2-64, test Fh, 1g, 3…100 Hz Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² EMC immunity influence ≤ ±0.5 % of span Extended EMC immunity: NAMUR NE 21, A criterion, burst ≤ ±1 % of span Response time for cable fault < 200 ms HART Communication Frequency range 0.5…2.5 kHz Signal / noise ratio min. 60 dB (0.5…10 kHz) Response time (0…90 %, 100…10 %) < 5 ms Default Settings Low/high limit 62 3.8 mA / 20.5 mA 1066540000/02/02.14 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) 7.6 ACT20X-SAI-HAO (HART-transparent Driver) 7.6.1 Description The ACT20X-SAI-HAO-S is a HART-protocol, transparent current output isolator. A DC current input signal from the safe area will be galvanically separated and drives controlled field devices in Ex Zone 0. It is available in a single-channel or two-channel version. The following HART-transparent drivers are available: Order No. Type Description 8965450000 ACT20X-SAI-HAO-S HART-transparent driver 8965460000 ACT20X-2SAI-2HAO-S 2-channel HART-transparent driver 1066540000/02/02.14 63 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) 7.6.2 Status/Alarm LEDs Illustration 7-18: Status/Alarm LEDs Condition LED 1 Channel 1 Channel 2 LED 3 Output Status Relay (NC) LED 2 Output OK OFF ON energized defective red fault state de-energized red flashing fault state de-energized red blinking fault state de-energized Channel 1 Device signal limit exceeded green flashing Channel 2 fixed loop break limit exceeded OK OFF ON energized defective red fault state de-energized red flashing fault state de-energized red blinking fault state de-energized signal limit exceeded green flashing fixed loop break limit exceeded No supply OFF OFF OFF OFF OFF de-energized Device failure OFF red OFF red OFF de-energized Blinking: 50% ON and 50% OFF __|¯¯¯¯|____|¯¯¯¯|____|¯¯¯¯|____ Flashing: 8% ON and 92% OFF __|¯|_______|¯|_______|¯|_______ Table 7-11: 64 Status/Alarm LEDs 1066540000/02/02.14 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) 7.6.3 Electrical Connections Terminal Function 11 Out − 12 Out + 13 Connector Terminal Function Connector 41 In – 42 In + input channel 1 43 In – 44 In + 51 GND 52 +24 V DC 53 NC 54 COM Ex output channel 1 14 21 Out − 22 Out + 23 Ex output channel 2 24 Table 7-12: 7.6.4 input channel 2 power supply status relay Electrical Connections Specifications Features • HART-compatible for 0.5...2.5 kHz • Configuration and monitoring via FDT/DTM-Software "WI-Manager". • The device can be mounted in the safe area and in Zone 2 / Class I, Division 2 and receive signals from Zone 0, 1, 2 and Zone 20, 21 and 22 including M1 / Class I/II/III, Division 1, Group A-G. • The mA current signal inputs are completely electrically isolated. • The device detects automatically whether an active or passive current signal is connected. • Extended self diagnostic: Monitoring of error events (e.g. cable breakage) via status relay. • Front LEDs indicates operation status and malfunction. • 3-way galvanic isolation between input, output and power supply. 1066540000/02/02.14 65 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) Illustration 7-19: 66 Functional Block Diagram 1066540000/02/02.14 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) Illustration 7-20: Applications Current Input Measurement range 3.5…23 mA Input resistance nom. 20 Ω + PTC 50 Ω Alarm setpoint, low/high limit (programmable) 0…28 mA Sensor error detection < 1 mA Current Output Signal range (programmable) 3.5…23 mA Load max. 20 mA / 725 Ω / 14.5 V DC Load stability ≤ 0.01 % of span / 100 Ω 1066540000/02/02.14 67 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) Sensor error detection (programmable) 3.5 mA / 23 mA / none Current limit ≤ 28 mA Accuracy Absolute Accuracy Temperature Coefficient General values ≤ ±0.1 % of span ≤ ±0.01 % of span / °C Basic values ≤ ±16 µA ≤ ±1.6 µA / °C Status Relay Safe Area Zone 2 Installation Voltage max. 125 V AC / 110 V 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A 0.5 A AC / 1 A DC Power max. 62.5 V AC / 32 W 16 VA / 32 W Power Supply Supply voltage 19.2…31.2 V DC Max. consumption (2-channels) ≤ 3.5 W Fuse 1.25 A / 250 V AC Isolation Voltages (reinforced insulation), Test/Operation Inputs / outputs / supply 2.6 kV AC / 300 V AC Input 1 to input 2 1.5 kV AC / 150 V AC Status relay to supply 1.5 kV AC / 150 V AC Environmental Specifications Ambient temperature -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % Calibration temperature +20…28 °C General Specifications Communications interface, adapter / configuration software / FDT-DTM device driver CBX200 USB / "WI-Manager" / ACT20X DTM Dimensions (H x W x D) 105.6 x 22.5 x 114.7 mm Protection degree IP20 Screw terminal torque 0.5 Nm 68 1066540000/02/02.14 Product Installation / Operation, ACT20X-SAI-HAO (HART-transparent Driver) Vibration IEC 60068-2-6, test Fc, 1g, 2…100 Hz Vibration, continuous IEC 60068-2-64, test Fh, 1g, 3…100 Hz Wire size, stranded wire AWG 26…14 / 0.13…2.08 mm² EMC immunity influence ≤ ±0.5 % of span Extended EMC immunity: NAMUR NE 21, A criterion, burst ≤ ±1 % of span HART Communication Frequency range 0.5…2.5 kHz Signal / noise ratio min. 60 dB (0.5…10 kHz) Response time (0…90 %, 100…10 %) < 5 ms Default Settings Low/high limit 1066540000/02/02.14 3.8 mA / 20.5 mA 69 Product Installation / Operation, ACT20-FEED-IN-PRO-S 7.7 ACT20-FEED-IN-PRO-S 7.7.1 Description The power feed-in unit ACT20-FEED-IN-PRO-S supplies the devices on the CH20M DIN rail bus with 24 V DC. At the same time, the ACT20-FEED-IN-PRO-S device reads the group error contact – optionally provided by the installed devices – from the CH20M rail bus and sends a message through the status relay to the external controller. Optionally, two power supplies can be connected for the primary and secondary supplies (backup). An installation in Zone 2 / Division 2 is also possible. Three LEDs show the status of the power supply and the error status. The ACT20-FEED-IN-PRO-S can supply a maximum of 4 A to feed up to 120 devices mounted on a CH20M rail bus. Quick identification of errors on the DIN rail bus is through the internal status relay. The ACT20FEED-IN-PRO-S device immediately recognises and displays when a power supply has failed. The supply is then switched automatically to the redundant power supply. The following Power Feed-In Unit is available: Order No. Type Description 8965500000 ACT20-FEED-IN-PRO-S Power Feed-In Unit 70 1066540000/02/02.14 Product Installation / Operation, ACT20-FEED-IN-PRO-S 7.7.2 Status/Alarm LEDs Illustration 7-21: Status/Alarm LEDs LED 1 (PWR) LED 2 (PWR BACKUP) LED 3 (Alarm) No power supply OFF OFF OFF de-energized de-energized Primary supply voltage green OFF red de-energized de-energized Secondary supply voltage OFF green red de-energized de-energized Primary and secondary supply voltage green green OFF Condition Status Relay (NC) 1) Status Relay (NO) 1) Collective error message active red de-energized de-energized inactive OFF energized 2) energized 2) 1) depends on collective error message 2) if the primary and/or secondary power supply is applied Table 7-13: Status/Alarm LEDs 1066540000/02/02.14 71 Product Installation / Operation, ACT20-FEED-IN-PRO-S 7.7.3 Electrical connections Terminal Function 41 NO 42 COM 43 NC Connector status relay 44 51 GND 52 +24 V DC 53 +24 V DC 54 GND 81 collective error contact 82 +24 V DC 83 GND power supply backup power supply Weidmüller DIN rail bus CH20M 84 85 Table 7-14: 7.7.4 Electrical connections Specifications Features • The power feed-in unit ACT20-FEED-IN-PRO-S detects errors from any of the devices mounted on the Weidmüller DIN rail bus CH20M and transmits a collective alarm to an external control system via the internal status relay. • Optional connection of two power supplies - a primary power supply and a backup power supply. • Redundant power supply can be obtained by mounting two feed-in units connected to two separate power supplies. • The status relay will be energised when the following conditions are met: - The power supply is present on terminal 51 and 52. - The backup power supply is present on terminal 53 and 54. If the backup power supply is not required, the included jumper must be employed between terminal 52 and 53. - There are no error signals from the devices connected to the Weidmüller DIN rail bus. • The device can be mounted in the safe area (non-hazardous) and in zone 2 / division 2. • The status of the power supply and the backup power supply is indicated by two green LEDs. • A malfunction is indicated by a red LED. 72 1066540000/02/02.14 Product Installation / Operation, ACT20-FEED-IN-PRO-S Illustration 7-22: Functional Block Diagram 1066540000/02/02.14 73 Product Installation / Operation, ACT20-FEED-IN-PRO-S * If the backup power supply is not required, the included jumper must be employed between terminal 52 and 53. Illustration 7-23: Applications Input Supply Voltage Supply voltage 21.6…26.4 V DC Backup supply voltage 21.6…26.4 V DC Trigger level for collective alarm on DIN rail bus < 21 V DC Efficiency > 97.9 % Internal consumption max. 2W 74 1066540000/02/02.14 Product Installation / Operation, ACT20-FEED-IN-PRO-S Output Power Supply Output voltage at 4 A Vinput power supply – 0.5 V DC Output current max. 4 A DC Output power max. 96 W Status Relay (Alarm),Safe Area Voltage max. 250 V AC / 30 V DC Current max. 2 A AC / 2 A DC Power max. 500 VA / 60 W Environmental Specifications Ambient temperature -20…+60 °C Storage temperature -20…+85 °C Relative humidity (non-condensation) < 95 % General Specifications Dimensions L x W x H 109.2 x 22.5 x 113.6 mm Protection degree IP 20 Screw terminal torque 0.5 Nm Wire size (stranded wire) AWG 26…14 / 0.13…2.08 mm Isolation test voltage 2.6 kV AC 1066540000/02/02.14 2 75 Product Installation / Operation, Female Plug BHZ 5.00 7.8 Female Plug BHZ 5.00 7.8.1 Description Among other things, the following female plug is available: Order No. Type Description 1069380000 BHZ 5.00/04/90LH BK/BL Female plug Features • Simple, component-friendly unplugging of the female plug using the integrated release lever. • Together with the captive, unique "Auto-Set" encoding, the uniquely detectable markers on the plug connection and in the front ensure misconnection-proof assignment of the connections. Both markers can be printed as cards in a PrintJet and then permanently snapped on. • Quick and easy operation by means of an integrated colour-coded release lever with grip tab and including a screwdriver pocket. • Touch protection for the male and female header on both sides. • During the installation: the quick all-purpose "Multi-Tool" screw head ensures a secure contact, userfriendly operation and less complexity. Additional features, such as the "Wire ready" technology, enable you to minimize wiring costs and increase customer satisfaction. 76 1066540000/02/02.14 Product Installation / Operation, Female Plug BHZ 5.00 7.8.2 Specifications General Specifications Product family OMNIMATE Housing - series CH20M Wire connection method Clamping yoke connection Conductor outlet direction 90° Pitch 5 mm / 0.197 inch Number of poles 4 Screwdriver blade DIN 5264 0.6 x 3.5 Tightening torque 0.4...0.6 Nm Clamping screw M 2.5 Stripping length 8 mm Dimensions L x W x H 14.6 x 22.4 x 29 mm Connectable Wires Clamping range 0.13...3.31 mm Solid, H05(07) V-U 0.2...2.5 mm 2 Flexible, H05(07) V-K 0.2...2.5 mm 2 With wire end ferrule, DIN 46228/1 0.25...2.5 mm 2 With wire end ferrule and plastic collar, DIN 46228/4 0.25...2.5 mm 2 2 Rated Data according to UL 1059 and CSA Rated voltage / Rated current (use group B) 300 V / 10 A Rated voltage / Rated current (use group C) 50 V / 10 A Rated voltage / Rated current (use group D) 300 V / 10 A Wire cross-section AWG 26...12 Rated Data according to DIN IEC Rated current, max. number of poles 10 A @ Tu = 20 °C, 9 A @ Tu = 40 °C Rated voltage / overvoltage category / pollution degree 400 V / II / 2 320 V / /II / 2 250 V / /II / 3 Rated impulse voltage / overvoltage category / pollution degree 4 kV / II / 2 4 kV / /II / 2 4 kV / /II / 3 1066540000/02/02.14 77 Product Installation / Operation, Female Plug BHZ 5.00 Material Data UL 94 flammability rating V-0 Isulating material PA 66 GV30 Colour black 78 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965340000 4 50102 Sheet 1-2 ACT20X-HDI-SDO-RNO-S 8965350000 4 50102 Sheet 1-2 ACT20X-HDI-SDO-RNC-S 8965360000 4 50588 Sheet 1-2 ACT20X-HDI-SDO-S 8965370000 4 50589 Sheet 1-2 ACT20X-2HDI-2SDO-RNO-S 8965380000 4 50589 Sheet 1-2 ACT20X-2HDI-2SDO-RNC-S 8965390000 4 50590 Sheet 1-2 ACT20X-2HDI-2SDO-S DANGER For safe installation of ACT20X-(2)HDI-(2)SDO-(RNO/RNC)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits have been installed in a type of protection other than “intrinsic safety”, the module must not be re-installed in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 79 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate KEMA 09ATEX 0168 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 80 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Illustration 7-24: ATEX Installation Drawing, (450102 Sheet 1-2, 450588 Sheet 1-2, 450589 Sheet 1-2, 450590 Sheet 1-2) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo 10.6 V DC Io 12 mA DC Po 32 mW Lo/Ro 1150 µH/Ω Group Co Lo IIC 2 µF 260 mH IIB 6 µF 780 mH IIA 18 µF 1000 mH I 90 µF 1000 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 1066540000/02/02.14 253 V, max. 400 Hz 81 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max. 3W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal CH1 (41, 42) and CH2 (43, 44) Digital Output, NPN Output Voltage max. 30 V DC Current max. 80 mA Terminal CH1 (41, 42) and CH2 (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 82 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965340000 4 50102 Sheet 3-4 ACT20X-HDI-SDO-RNO-S 8965350000 4 50102 Sheet 3-4 ACT20X-HDI-SDO-RNC-S 8965360000 4 50588 Sheet 3-4 ACT20X-HDI-SDO-S 8965370000 4 50589 Sheet 3-4 ACT20X-2HDI-2SDO-RNO-S 8965380000 4 50589 Sheet 3-4 ACT20X-2HDI-2SDO-RNC-S 8965390000 4 50590 Sheet 3-4 ACT20X-2HDI-2SDO-S DANGER For safe installation of ACT20X-(2)HDI-(2)SDO-(RNO/RNC)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits have been installed in a type of protection other than “intrinsic safety”, the module must not be re-installed in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 83 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate KEM 09.0072 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 84 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Illustration 7-25: IECEx Installation Drawing, (450102 Sheet 3-4, 450588 Sheet 3-4, 450589 Sheet 3-4, 450590 Sheet 3-4) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo 10.6 V DC Io 12 mA DC Po 32 mW Lo/Ro 1150 µH/Ω Group Co Lo IIC 2 µF 260 mH IIB 6 µF 780 mH IIA 18 µF 1000 mH I 90 µF 1000 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 1066540000/02/02.14 253 V, max. 400 Hz 85 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max. 3W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal CH1 (41, 42) and CH2 (43, 44) Digital Output, NPN Output Voltage max. 30 V DC Current max. 80 mA Terminal CH1 (41, 42) and CH2 (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 86 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965340000 4 50102 Sheet 5-6 ACT20X-HDI-SDO-RNO-S 8965350000 4 50102 Sheet 5-6 ACT20X-HDI-SDO-RNC-S 8965360000 4 50588 Sheet 5-6 ACT20X-HDI-SDO-S 8965370000 4 50589 Sheet 5-6 ACT20X-2HDI-2SDO-RNO-S 8965380000 4 50589 Sheet 5-6 ACT20X-2HDI-2SDO-RNC-S 8965390000 4 50590 Sheet 5-6 ACT20X-2HDI-2SDO-S DANGER For safe installation of ACT20X-(2)HDI-(2)SDO-(RNO/RNC)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. The installation and wiring must be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be supplied from a Power Supply having double or reinforced insulation. The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. The module must be installed in an enclosure suitable for the environment where it is used. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure according to the regulations in the CEC for Canada or NEC for USA. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG 26-14. The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 87 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us Certificate 3038275C / 3038275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 Standards Canada Zones: Divisions: USA Zones: Divisions: 88 E60079-0, E60079-11, E60079-15 CSA 22.2-157, CSA 22.2-213 UL 60079-0, UL 60079-11, UL 60079-15 FM3600, FM3610, FM3611, FM3810 1066540000/02/02.14 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Illustration 7-26: FM Installation Drawing, (450102 Sheet 5-6, 450588 Sheet 5-6, 450589 Sheet 5-6, 450590 Sheet 5-6) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo, Vt 10.6 V DC Io, Isc 12 mA DC Po, Pt 32 mW Lo/Ro, La/Ra 1150 µH/Ω Group C o, C a L o, L a IIC or A, B 2 µF 260 mH IIB or C, E, F 6 µF 780 mH IIA or D, G 18 µF 1000 mH 1066540000/02/02.14 89 Appendix A. Installation Drawings ACT20X-HDI-SDO (NAMUR Pulse Isolator) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max. 3W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal CH1 (41, 42) and CH2 (43, 44) Digital Output, NPN Output Voltage max. 30 V DC Current max. 80 mA Terminal CH1 (41, 42) and CH2 (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 90 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965470000 4 50594 Sheet 1-2 ACT20X-HTI-SAO-S 8965480000 4 50595 Sheet 1-2 ACT20X-2HTI-2SAO-S DANGER For safe installation of the Temperature and mA Converter ACT20X-(2)HTI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits (Terminals 11…14, 21…24) have been installed in a type of protection other than “intrinsic safety”, the module must not be re-installed in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 91 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate KEMA 10ATEX 0020 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 92 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-27: ATEX Installation Drawing (1), (450594 Sheet 1-2, 450595 Sheet 1-2) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo 8.7 V Io 18.4 mA Po 40 mW Lo/Ro 892 µH/Ω Ui 10 V Ii 30 mA Ci 30 nF Li 820 nH Group Co Lo IIC 5 µF 100 mH IIB 50 µF 300 mH IIA or I 1000 µF 700 mH 1066540000/02/02.14 93 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 94 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-28: ATEX Installation Drawing (2), (450594 Sheet 1-2, 450595 Sheet 1-2) Terminal CH1 (13), CH2 (22) Ex Input Uo 17.4 V Io 18.4 mA Po 80 mW Lo/Ro 445 µH/Ω Ui 10 V Ii 30 mA Ci 15 nF Li 1.7 µH Group Co Lo IIC 0.3 µF 80 mH IIB 1.6 µF 250 mH IIA or I 8 µF 600 mH 1066540000/02/02.14 95 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 96 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965470000 4 50594 Sheet 3-4 ACT20X-HTI-SAO-S 8965480000 4 50595 Sheet 4-6 ACT20X-2HTI-2SAO-S DANGER For safe installation of the Temperature and mA Converter ACT20X-(2)HTI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits (Terminals 11…14, 21…24) have been installed in a type of protection other than “intrinsic safety”, the module must not be reinstalled in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 97 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate KEM 09.0092 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 98 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-29: IECEx Installation Drawing (1), (450594 Sheet 3-4, 450595 Sheet 4-6) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo 8.7 V Io 18.4 mA Po 40 mW Lo/Ro 892 µH/Ω Ui 10 V Ii 30 mA Ci 30 nF Li 820 nH Group Co Lo IIC 5 µF 100 mH IIB 50 µF 300 mH IIA or I 1000 µF 700 mH 1066540000/02/02.14 99 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 100 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-30: IECEx Installation Drawing (2), (450594 Sheet 3-4, 450595 Sheet 4-6) Terminal CH1 (13), CH2 (22) Ex Input Uo 17.4 V Io 18.4 mA Po 80 mW Lo/Ro 445 µH/Ω Ui 10 V Ii 30 mA Ci 15 nF Li 1.7 µH Group Co Lo IIC 0.3 µF 80 mH IIB 1.6 µF 250 mH IIA or I 8 µF 600 mH 1066540000/02/02.14 101 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 102 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965470000 4 50594 Sheet 5-6 ACT20X-HTI-SAO-S 8965480000 4 50595 Sheet 7-9 ACT20X-2HTI-2SAO-S DANGER For safe installation of the Temperature and mA Converter ACT20X-(2)HTI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. The installation and wiring must be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be supplied from a Power Supply having double or reinforced insulation. The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. The module must be installed in an enclosure suitable for the environment where it is used. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure according to the regulations in the CEC for Canada or NEC for USA. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG 26-14. The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 103 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us Certificate 3038275C / 308275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 Standards Canada Zones: Divisions: USA Zones: Divisions: 104 E60079-0, E60079-11, E60079-15 CSA 22.2-157, CSA 22.2-213 UL 60079-0, UL 60079-11, UL 60079-15 FM3600, FM3610, FM3611, FM3810 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-31: FM Installation Drawing (1), (450594 Sheet 5-6, 450595 Sheet 7-9) Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24) Ex Input Uo, Vt 8.7 V Io, It 18.4 mA Po 40 mW Lo/Ro 892 µH/Ω Ui 10 V Ii 30 mA Ci 30 nF Li 820 nH Group C o, C a L o, L a IIC Group A, B 5 µF 100 mH IIB Group C, E, F 50 µF 300 mH IIA Group D, G 1000 µF 700 mH 1066540000/02/02.14 105 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 106 1066540000/02/02.14 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Illustration 7-32: FM Installation Drawing (2), (450594 Sheet 5-6, 450595 Sheet 7-9) Terminal CH1 (13), CH2 (22) Ex Input Uo, Vt 17.4 V Io, It 18.4 mA Po 80 mW Lo/Ro 445 µH/Ω Ui 10 V Ii 30 mA Ci 15 nF Li 1.7 µH 1066540000/02/02.14 107 Appendix B. Installation Drawings ACT20X-HTI-SAO (Temperature/mA Converter) Group C o, C a L o, L a IIC or Group A, B 0.3 µF 80 mH IIB or Group C, E, F 1.6 µF 250 mH IIA or Group D, G 8 µF 600 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 108 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965400000 4 51478 Sheet 1-2 ACT20X-SDI-HDO-L-S 8965410000 4 51478 Sheet 1-2 ACT20X-SDI-HDO-H-S 8965420000 4 51478 Sheet 1-2 ACT20X-2SDI-2HDO-S DANGER For safe installation of ACT20X-(2)SDI-(2)HDO-(L/H)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits have been installed in a type of protection other than “intrinsic safety”, the module must not be re-installed in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 109 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate KEMA 10ATEX 0019 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 110 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Illustration 7-33: ATEX Installation Drawing, (451478 Sheet 1-2) Terminal CH1 (41, 42) and CH2 (43, 44) Input Voltage max 28 V DC Trigger: NPN Low < 2 V, High > 4 V Trigger: PNP Low < 8 V, High > 10 V Terminal (11–12, 21–22) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4.2 mH 54 µH/Ω Io 93 mA IIB 640 nF 16.8 mH 218 µH/Ω Po 0.65 W IIA 2.1 µF 32.6 mH 436 µH/Ω I 3.76 µF 47 mH 717 µH/Ω 1066540000/02/02.14 111 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (11–13, 21–23) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 3.5 mH 50 µH/Ω Io 100 mA IIB 640 nF 14.2 mH 201 µH/Ω Po 0.70 W IIA 2.1 µF 27.6 mH 402 µH/Ω I 3.76 µF 46 mH 667 µH/Ω Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.9 mH 46 µH/Ω Io 110 mA IIB 640 nF 11.8 mH 184 µH/Ω Po 0.77 W IIA 2.1 µF 22.8 mH 369 µH/Ω I 3.76 µF 38 mH 607 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.69 mH 44 µH/Ω Io 115 mA IIB 640 nF 10.8 mH 176 µH/Ω Po 0.81 W IIA 2.1 µF 20.8 mH 353 µH/Ω I 3.76 µF 33 mH 578 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC – – – Io 125 mA IIB 640 nF 9.1 mH 163 µH/Ω Po 0.88 W IIA 2.1 µF 17.6 mH 327 µH/Ω I 3.76 µF 28 mH 533 µH/Ω Terminal (11–14, 21–24) Terminal (11–12) Terminal (11–13) 112 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (11–14) Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF – – Io 135 mA IIB 640 nF 7.8 mH 150 µH/Ω Po 0.95 W IIA 2.1 µF 15.1 mH 301 µH/Ω I 3.76 µF 24 mH 493 µH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max 3.5 W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 1066540000/02/02.14 113 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) 114 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965400000 4 51478 Sheet 3-4 ACT20X-SDI-HDO-L-S 8965410000 4 51478 Sheet 3-4 ACT20X-SDI-HDO-H-S 8965420000 4 51478 Sheet 3-4 ACT20X-2SDI-2HDO-S DANGER For safe installation of ACT20X-(2)SDI-(2)HDO-(L/H)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. If the sensor circuits have been installed in a type of protection other than “intrinsic safety”, the module must not be re-installed in type of protection ”intrinsic safety”. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 115 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate KEM 09.0071 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 116 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Illustration 7-34: IECEx Installation Drawing, (451478 Sheet 3-4) Terminal CH1 (41, 42) and CH2 (43, 44) Input Voltage max 28 V DC Trigger: NPN Low < 2 V, High > 4 V Trigger: PNP Low < 8 V, High > 10 V Terminal (11–12, 21–22) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4.2 mH 54 µH/Ω Io 93 mA IIB 640 nF 16.8 mH 218 µH/Ω Po 0.65 W IIA 2.1 µF 32.6 mH 436 µH/Ω I 3.76 µF 32.6 mH 436 µH/Ω 1066540000/02/02.14 117 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (11–13, 21–23) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 3.5 mH 50 µH/Ω Io 100 mA IIB 640 nF 14.2 mH 201 µH/Ω Po 0.70 W IIA 2.1 µF 27.6 mH 402 µH/Ω I 3.76 µF 46 mH 667 µH/Ω Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.9 mH 46 µH/Ω Io 100 mA IIB 640 nF 12.8 mH 184 µH/Ω Po 0.70 W IIA 2.1 µF 22.8 mH 369 µH/Ω I 3.76 µF 38 mH 607 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.69 mH 44 µH/Ω Io 115 mA IIB 640 nF 10.8 mH 176 µH/Ω Po 0.81 W IIA 2.1 µF 20.8 mH 353 µH/Ω I 3.76 µF 33 mH 578 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC – – – Io 125 mA IIB 640 nF 9.1 mH 162 µH/Ω Po 0.88 W IIA 2.1 µF 17.6 mH 325 µH/Ω I 3.76 µF 28 mH 533 µH/Ω Terminal (11–14, 21–24) Terminal (11–12) Terminal (11–13) 118 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (11–14) Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC – – – Io 135 mA IIB 640 nF 7.8 mH 150 µH/Ω Po 0.95 W IIA 2.1 µF 15.1 mH 301 µH/Ω I 3.76 µF 24 mH 493 µH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max 3.5 W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 1066540000/02/02.14 119 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) 120 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965400000 4 51478 Sheet 5-6 ACT20X-SDI-HDO-L-S 8965410000 4 51478 Sheet 5-6 ACT20X-SDI-HDO-H-S 8965420000 4 51478 Sheet 5-6 ACT20X-2SDI-2HDO-S DANGER For safe installation of ACT20X-(2)SDI-(2)HDO-(L/H)-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. The installation and wiring shall be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be supplied from a Power Supply having double or reinforced insulation. The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. The module must be installed in an enclosure suitable for the environment where it is used. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure according to the regulations in the CEC for Canada or NEC for USA. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG 26-14. The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 121 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us Certificate 3038275C / 3038275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 Standards Canada Zones: Divisions: USA Zones: Divisions: 122 E60079-0, E60079-11, E60079-15 CSA 22.2-157, CSA 22.2-213 UL 60079-0, UL 60079-11, UL 60079-15 FM3600, FM3610, FM3611, FM3810 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Illustration 7-35: FM Installation Drawing, (451478 Sheet 5-6) Terminal CH1 (41, 42) and CH2 (43, 44) Input Voltage max 28 V DC Trigger: NPN Low < 2 V, High > 4 V Trigger: PNP Low < 8 V, High > 10 V Terminal (11–12, 21–22) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4.2 mH 54 µH/Ω Io 93 mA IIB 640 nF 16.8 mH 218 µH/Ω Po 0.65 W IIA 2.1 µF 32.6 mH 436 µH/Ω 1066540000/02/02.14 123 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (11–13, 21–23) Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 3.5 mH 50 µH/Ω Io 100 mA IIB 640 nF 14.2 mH 201 µH/Ω Po 0.70 W IIA 2.1 µF 27.6 mH 402 µH/Ω Ex Output 8965400000 (ACT20X-SDI-HDO-L-S) 8965420000 (ACT20X-2SDI-2HDO-S) Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.9 mH 46 µH/Ω Io 100 mA IIB 640 nF 12.8 mH 184 µH/Ω Po 0.70 W IIA 2.1 µF 22.8 mH 369 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 2.69 mH 44 µH/Ω Io 115 mA IIB 640 nF 10.8 mH 176 µH/Ω Po 0.81 W IIA 2.1 µF 20.8 mH 353 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC – – – Io 125 mA IIB 640 nF 9.1 mH 162 µH/Ω Po 0.88 W IIA 2.1 µF 17.6 mH 325 µH/Ω Ex Output 8965410000 (ACT20X-SDI-HDO-H-S) Group Co Lo Lo/Ro Uo 28 V IIC – – – Io 135 mA IIB 640 nF 7.8 mH 150 µH/Ω Po 0.95 W IIA 2.1 µF 15.1 mH 301 µH/Ω Terminal (11–14, 21–24) Terminal (11–12) Terminal (11–13) Terminal (11–14) 124 1066540000/02/02.14 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Power max 3.5 W Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 1066540000/02/02.14 125 Appendix C. Installation Drawings ACT20X-SDI-HDO (Solenoid/Alarm Driver) 126 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965490000 4 51481 Sheet 1-4 ACT20X-HUI-SAO-S DANGER For safe installation of the Universal Converter ACT20X-HUI-SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure in type of protection Ex-n or Ex-e, providing an IP protection of at least IP54. Cable entry devices and blanking elements shall fulfil the same requirements. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 127 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate KEMA 10ATEX 0071 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 128 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-36: ATEX Installation Drawing (1), (451481 Sheet 1-4) Terminal (21, 22) and (21, 23) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 1 µH 1066540000/02/02.14 129 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (21–24, 22–24) Input Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4 mH 54 µH/Ω Io 93 mA IIB 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or I 2.1 µF 32 mH 436 µH/Ω Group Co Lo Lo/Ro Terminal (21–23) Input Uo 28 V IIC 80 nF 1000 mH 4 mH/Ω Io 1.1 mA IIB 640 nF 1000 mH 17 mH/Ω Po 8 mW IIA or I 2.1 µF 1000 mH 35 mH/Ω Group Co Lo Lo/Ro Terminal (21–22) Input Uo 8.3 V IIC 7 µF 1000 mH 100 mH/Ω Io 0.2 mA IIB 73 µF 1000 mH 400 mH/Ω Po 0.4 mW IIA or I 1000 µF 1000 mH 800 mH/Ω Group Co Lo Lo/Ro Terminal (11, 12, 13, 14) Input Uo 8.3 V IIC 7 µF 207 mH 1 mH/Ω Io 13.1 mA IIB 73 µF 828 mH 5 mH/Ω Po 27.3 mW IIA or I 1000 µF 1000 mH 10 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (41, 42) Output Current 130 0/4…20 mA 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 131 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-37: ATEX Installation Drawing (2), (451481 Sheet 1-4) Terminal (24-22) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 2 µH 132 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (24–22, 22–21) Input Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4.2 mH 54 µH/Ω Io 93 mA IIB 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or I 2.1 µF 32 mH 436 µH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 133 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-38: ATEX Installation Drawing (3), (451481 Sheet 1-4) Terminal (21-22) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 1 µH 134 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (22–21, 21–22) Input Group Co Lo Lo/Ro Uo 16.6 V IIC 0.4 µF 1000 mH 25 mH/Ω Io 0.2 mA IIB 2.3 µF 1000 mH 100 mH/Ω Po 0.8 mW IIA or I 9.5 µF 1000 mH 200 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 135 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) 136 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965490000 4 51481 Sheet 5-8 ACT20X-HUI-SAO-S DANGER For safe installation of the Universal Converter ACT20X-HUI-SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. For group I (mining), the parameters for group IIA apply. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 137 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate KEM 10.0034 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 138 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-39: IECEx Installation Drawing (1), (451481 Sheet 5-8) Terminal (21, 22) and (21, 23) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 1 µH 1066540000/02/02.14 139 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (21–24, 22–24) Input Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4 mH 54 µH/Ω Io 93 mA IIB 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or I 2.1 µF 32 mH 436 µH/Ω Group Co Lo Lo/Ro Terminal (21–23) Input Uo 28 V IIC 80 nF 1000 mH 4 mH/Ω Io 1.1 mA IIB 640 nF 1000 mH 17 mH/Ω Po 8 mW IIA or I 2.1 µF 1000 mH 35 mH/Ω Group Co Lo Lo/Ro Terminal (21–22) Input Uo 8.3 V IIC 7 µF 1000 mH 100 mH/Ω Io 0.2 mA IIB 73 µF 1000 mH 400 mH/Ω Po 0.4 mW IIA or I 1000 µF 1000 mH 800 mH/Ω Group Co Lo Lo/Ro Terminal (11, 12, 13, 14) Input Uo 8.3 V IIC 7 µF 207 mH 1 mH/Ω Io 13.1 mA IIB 73 µF 828 mH 5 mH/Ω Po 27.3 mW IIA or I 1000 µF 1000 mH 10 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (41, 42) Output Current 140 0/4…20 mA 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 141 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-40: IECEx Installation Drawing (2), (451481 Sheet 5-8) Terminal (24-22) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 2 µH 142 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (24–22, 22–21) Input Group Co Lo Lo/Ro Uo 28 V IIC 80 nF 4.2 mH 54 µH/Ω Io 93 mA IIB 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or I 2.1 µF 32 mH 436 µH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 143 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-41: IECEx Installation Drawing (3), (451481 Sheet 5-8) Terminal (21-22) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 2 µH 144 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (22–21, 21–22) Input Group Co Lo Lo/Ro Uo 16.6 V IIC 0.4 µF 1000 mH 25 mH/Ω Io 0.2 mA IIB 2.3 µF 1000 mH 100 mH/Ω Po 0.8 mW IIA or I 9.5 µF 1000 mH 200 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 145 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) 146 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965490000 4 51481 Sheet 9-12 ACT20X-HUI-SAO-S DANGER For safe installation of the Universal Converter ACT20X-HUI-SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. The installation and wiring must be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure having an IP protection of at least IP54. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG 26-14. In type of protection “intrinsic safety for group IIIC” the parameters for intrinsic safety for gas group IIB are applicable. The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 147 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us Certificate 3038275C / 3038275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 Standards Canada Zones: Divisions: USA Zones: Divisions: 148 E60079-0, E60079-11, E60079-15 CSA 22.2-157, CSA 22.2-213 UL 60079-0, UL 60079-11, UL 60079-15 FM3600, FM3610, FM3611, FM3810 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-42: FM Installation Drawing (1), (451481 Sheet 9-12) Terminal (21-22) and (21-23) Input Ui, Vmax 30 V Ii, Imax 120 mA Pi 900 mW Ci 3 nF Li 1 µH 1066540000/02/02.14 149 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (21–24, 22–24) Input Group Co Lo Lo/Ro Uo, VOC 28 V IIC or A, B 80 nF 4 mH 54 µH/Ω Io, ISC 93 mA IIB or C, E, F 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or D, G 2.1 µF 32 mH 436 µH/Ω Group Co Lo Lo/Ro Terminal (21–23) Input Uo, VOC 28 V IIC or A, B 80 nF 1000 mH 4 mH/Ω Io, ISC 1.1 mA IIB or C, E, F 640 nF 1000 mH 17 mH/Ω Po 8 mW IIA or D, G 2.1 µF 1000 mH 35 mH/Ω Group Co Lo Lo/Ro Terminal (21–22) Input Uo, VOC 8.3 V IIC or A, B 7 µF 1000 mH 100 mH/Ω Io, ISC 0.2 mA IIB or C, E, F 73 µF 1000 mH 400 mH/Ω Po 0.4 mW IIA or D, G 1000 µF 1000 mH 800 mH/Ω Group Co Lo Lo/Ro Terminal (11, 12, 13, 14) Input Uo, VOC 8.3 V IIC or A, B 7 µF 207 mH 1 mH/Ω Io, ISC 13.1 mA IIB or C, E, F 73 µF 828 mH 5 mH/Ω Po 27.3 mW IIA or D, G 1000 µF 1000 mH 10 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (41, 42) Output Current 150 0/4…20 mA 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 151 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-43: 152 FM Installation Drawing (2), (451481 Sheet 9-12) 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (24-22) Input Ui 30 V Ii 120 mA Pi 900 mW Ci 3 nF Li 2 µH Terminal (24–22, 22–21) Input Group Co Lo Lo/Ro Uo 28 V IIC or A, B 80 nF 4 mH 54 µH/Ω Io 93 mA IIB or C, E, F 640 nF 16 mH 218 µH/Ω Po 0.65 W IIA or D, G 2.1 µF 32 mH 436 µH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 153 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Illustration 7-44: 154 FM Installation Drawing (3), (451481 Sheet 9-12) 1066540000/02/02.14 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) Terminal (21-22) Input Ui, Vmax 30 V Ii, Imax 120 mA Pi 900 mW Ci 3 nF Li 2 µH Terminal (22–21, 21–22) Input Group Co Lo Lo/Ro Uo, VOC 16.6 V IIC or A, B 0.4 µF 1000 mH 25 mH/Ω Io, ISC 0.2 mA IIB or C, E, F 2.3 µF 1000 mH 100 mH/Ω Po 0.8 mW IIA or D, G 9.5 µF 1000 mH 200 mH/Ω Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (43, 44) Relay Output Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W Terminal (53, 54) 1066540000/02/02.14 155 Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter) 156 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965430000 4 53449 Sheet 1-4 ACT20X-HAI-SAO-S 8965440000 4 53449 Sheet 1-4 ACT20X-2HAI-2SAO-S DANGER For safe installation of ACT20X-(2)HAI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure in type of protection Ex-n or Ex-e, providing an IP protection of at least IP54. Cable entry devices and blanking elements shall fulfil the same requirements. In type of protection “intrinsic safety ia IIIC” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. The Loop Supply and Current Input terminals for the same channel shall not be applied at the same time. The wiring of unused terminals is not allowed. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 157 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate DEKRA 11ATEX 0131 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 158 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-45: ATEX Installation Drawing (1), (453449 Sheet 1-4) Terminal CH1 (13, 14), CH2 (23, 24) Ex Input (Loop Current Source) Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH 1066540000/02/02.14 159 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 160 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-46: ATEX Installation Drawing (2), (453449 Sheet 1-4) Terminal CH1 (11, 12), CH2 (21, 22) Ex Input (External Current Source) Uo 0V Io 0 mA Po 0 mW Ui 30 V Ii 120 mA Pi 0.85 W Ci 2 nF Li 0 µH 1066540000/02/02.14 161 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V AC, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 162 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-47: ATEX Installation Drawing (3), (453449 Sheet 1-4) Terminal CH1 (14), CH2 (22) Ex Input (Loop Current Source Channel 1 to Channel 2) Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH 1066540000/02/02.14 163 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 164 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-48: ATEX Installation Drawing (4), (453449 Sheet 1-4) Terminal CH1 (12), CH2 (21) Ex Input (External Current Source Channel 1 to Channel 2) Uo 0V Io 0 mA Po 0 mW Ui 30 V Ii 120 mA Pi 0.85 W Ci 4 nF Li 0 µH 1066540000/02/02.14 165 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 166 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965430000 4 53449 Sheet 5-8 ACT20X-HAI-SAO-S 8965440000 4 53449 Sheet 5-8 ACT20X-2HAI-2SAO-S DANGER For safe installation of ACT20X-(2)HAI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “intrinsic safety ia IIIC” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. The Loop Supply and Current Input terminals for the same channel shall not be applied at the same time. The wiring of unused terminals is not allowed. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 167 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate DEK 11.0050 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 168 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-49: IECEx Installation Drawing (1), (453449 Sheet 5-8) Terminal CH1 (13, 14), CH2 (23, 24) Ex Input (Loop Current Source) Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH 1066540000/02/02.14 169 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 170 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-50: IECEx Installation Drawing (2), (453449 Sheet 5-8) Terminal CH1 (11, 12), CH2 (21, 22) Ex Input (External Current Source) Uo 0V Io 0 mA Po 0 mW Ui 30 V Ii 120 mA Pi 0.85 W Ci 2 nF Li 0 µH 1066540000/02/02.14 171 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V AC, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 172 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-51: IECEx Installation Drawing (3), (453449 Sheet 5-8) Terminal CH1 (14), CH2 (22) Ex Input (Loop Current Source Channel 1 to Channel 2) Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH 1066540000/02/02.14 173 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 174 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-52: IECEx Installation Drawing (4), (453449 Sheet 5-8) Terminal CH1 (12), CH2 (21) Ex Input (External Current Source Channel 1 to Channel 2) Uo 0V Io 0 mA Po 0 mW Ui 30 V Ii 120 mA Pi 0.85 W Ci 4 nF Li 0 µH 1066540000/02/02.14 175 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC 0.08 µF 3 mH IIB 0.6 µF 12 mH IIA 2.15 µF 25 mH I 3.76 µF 30 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 176 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965430000 4 53449 Sheet 9-13 ACT20X-HAI-SAO-S 8965440000 4 53449 Sheet 9-13 ACT20X-2HAI-2SAO-S DANGER For safe installation of ACT20X-(2)HAI-(2)SAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. In Class I, Division 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of the Class I, Division 2 wiring methods specified in the National Electrical Code (ANSI/NFPA 70) or Canadian Electrical Code (C22.1). The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure having an IP protection of at least IP54. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG 26-14. The Loop Supply and Current Input terminals for the same channel shall not be applied at the same time. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 177 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us certificate 3038275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 178 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-53: FM Installation Drawing (1), (453449 Sheet 9-13) Terminal CH1 (13, 14), CH2 (23, 24) Ex Input (Loop Current Source) Uo, VOC 28 V Io, ISC 93 mA Po 0.65 W 1066540000/02/02.14 179 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC or A, B 0.08 µF 3 mH IIB or C, E, F 0.6 µF 12 mH IIA or D, G 2.15 µF 25 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 180 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-54: FM Installation Drawing (2), (453449 Sheet 9-13) Terminal CH1 (11, 12), CH2 (21, 22) Ex Input (External Current Source) Uo, VOC 0V Io, ISC 0 mA Po 0 mW Ui, Vmax 30 V Ii, Imax 120 mA Pi 0.85 W Ci 2 nF Li 0 µH 1066540000/02/02.14 181 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC or A, B 0.08 µF 3 mH IIB or C, E, F 0.6 µF 12 mH IIA or D, G 2.15 µF 25 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 182 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-55: FM Installation Drawing (3), (453449 Sheet 9-13) Terminal CH1 (14), CH2 (22) Ex Input (Loop Current Source Channel 1 to Channel 2) Uo, Voc 28 V Io, Isc 93 mA Po 0.65 W Group Co Lo IIC or A, B 0.08 µF 3 mH IIB or C, E, F 0.6 µF 12 mH IIA or D, G 2.15 µF 25 mH 1066540000/02/02.14 183 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 184 1066540000/02/02.14 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Illustration 7-56: FM Installation Drawing (4), (453449 Sheet 9-13) Terminal CH1 (12), CH2 (21) Ex Input (External Current Source Channel 1 to Channel 2) Uo 0V Io 0 mA Po 0 mW Ui, Vmax 30 V Ii, Imax 120 mA Pi 0.85 W Ci 4 nF Li 0 µH 1066540000/02/02.14 185 Appendix E. Installation Drawings ACT20X-HAI-SAO (HART-transparent Repeater) Group Co Lo IIC or A, B 0.08 µF 3 mH IIB or C, E, F 0.6 µF 12 mH IIA or D, G 2.15 µF 25 mH Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Output Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 186 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965450000 4 53448 Sheet 1-2 ACT20X-SAI-HAO-S 8965460000 4 53448 Sheet 1-2 ACT20X-2SAI-2HAO-S DANGER For safe installation of ACT20X-(2)SAI-(2)HAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “Ex ia Da” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in EN 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 187 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. ATEX Certificate DEKRA 11ATEX 0164 X Marking II (1) G [Ex ia Ga] IIC/IIB/IIA II 3 G Ex nA nC IIC T4 Gc II (1) D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, EN 60079-26:2007 188 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Illustration 7-57: ATEX Installation Drawing, (453448 Sheet 1-2) Terminal CH1 (11, 12), CH2 (21, 22) Ex Output Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 4 mH IIB 0.65 µF 16 mH IIA 2.15 µF 32 mH I 3.76 µF 46 mH 1066540000/02/02.14 189 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Current Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 190 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965450000 4 53448 Sheet 3-4 ACT20X-SAI-HAO-S 8965460000 4 53448 Sheet 3-4 ACT20X-2SAI-2HAO-S DANGER For safe installation of ACT20X-(2)SAI-(2)HAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. In type of protection “Ex ia Da” the parameters for intrinsic safety for gas group IIB are applicable. The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. Do not separate connectors when energized and an explosive gas mixture is present. The wiring of unused terminals is not allowed. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm 1066540000/02/02.14 191 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. IECEx Certificate DEK 11.0059 X Marking Ex nA nC IIC T4 Gc [Ex ia Ga] IIC/IIB/IIA [Ex ia Da] IIIC [Ex ia Ma] I Standards IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-15:2010, IEC 60079-26:2007 192 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Illustration 7-58: IECEx Installation Drawing, (453448 Sheet 3-4) Terminal CH1 (11, 12), CH2 (21, 22) Ex Output Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 4 mH IIB 0.65 µF 16 mH IIA 2.15 µF 32 mH I 3.76 µF 25 mH 1066540000/02/02.14 193 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Current Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 194 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965450000 4 53448 Sheet 5-6 ACT20X-SAI-HAO-S 8965460000 4 53448 Sheet 5-6 ACT20X-2SAI-2HAO-S DANGER For safe installation of ACT20X-(2)SAI-(2)HAO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. In Class I, Division 2 or Zone 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of Class I, Division 2 wiring methodes specified in the National Electrical Code (ANSI/NFPA 70) or the Canadian Electrical code (C22.1). The module must be installed in pollution degree 2, overvoltage category II as defined in IEC 60664-1. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure having an IP protection of at least IP54. The module is galvanically isolated and does not require grounding. Use 60/75 °C copper conductors in the wire size AWG (26-14). The year of manufacture can be taken from the first two digits in the serial number. 1066540000/02/02.14 195 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) CBX200 – "WI-Manager" Software For installation in Zone 2 / Division 2 the following must be observed: - The CBX200 is an interface cable for configuration via PC. - Configuration must be performed only in a safe area. c-FM-us Certificate 3038275 Marking Install in CL I DIV2 GP A-D T4 Provides IS Circuits to CL I-III DIV 1/2 GP A-G or CL I Zn2 AEx/Ex nA nC [ia] IIC T4 Standards Canada Zones: CAN/CSA-C22.2 E60079-0, CAN/CSA-C22.2 E60079-11, CAN/CSA-C22.2 E60079-15 Divisions: CSA 22.2-157, CSA 22.2-213 USA Zones: ANSI/ISA 60079-0, ANSI/ISA 60079-11, ANSI/ISA 60079-15 Divisions: FM3600, FM3610, FM3611, FM3810 196 1066540000/02/02.14 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Illustration 7-59: FM Installation Drawing, (453448 Sheet 5-6) Terminal CH1 (11, 12), CH2 (21, 22) Ex Output Uo 28 V Io 93 mA Po 0.65 W Group Co Lo IIC 0.08 µF 4 mH IIB 0.65 µF 16 mH IIA 2.15 µF 32 mH 1066540000/02/02.14 197 Appendix F. Installation Drawings ACT20X-SAI-HAO (HART-transparent Driver) Terminal (41, 42, 43, 44) and (51, 52, 53, 54) Supply / Current Input Um 253 V, max. 400 Hz Terminal (51, 52) Supply Voltage 19.2…31.2 V DC Terminal (53, 54) Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 125 V AC / 110 V DC 32 V AC / 32 V DC Current max. 0.5 A AC / 0.3 A DC 0.5 A AC / 1 A DC Power max. 62.5 VA / 32 W 16 VA / 32 W 198 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) ATEX Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965500000 4 52691 Sheet 1-2 ACT20-FEED-IN-PRO-S DANGER For safe installation of ACT20-FEED-IN-PRO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. DANGER Do not install or remove modules from the Power Rail unless area is known to be nonhazardous. The ACT20-FEED-IN-PRO-S must be supplied from a power source with double or reinforced insulation to mains. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. Cable entry devices and blanking elements shall fulfil the same requirements. Transients are suppressed by an internal transient protection device, which is set to a level not exeeding 40% of the rated voltage. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm ATEX Certificate DEKRA 11ATEX 0129 X Marking II 3 G Ex nA nC IIC T4 Gc Standards 1066540000/02/02.14 EN 60079-0:2012, EN 60079-15:2010 199 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) Illustration 7-60: ATEX Installation Drawing, (452691 Sheet 1-2) Terminal (51, 52) Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (53, 54) Backup Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (41, 42, 43) Power Rail Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 200 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Use CH20M BUS-ADP (Bus Cover) to prevent the open mounting rail from being accidentally short circuited. Redundant ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Power is supplied to the Power Rail from two ACT20-FEED-IN-PRO-S modules. Both modules have connections for normal supply and backup supply. 1066540000/02/02.14 201 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) 202 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) IECEx Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965500000 4 52691 Sheet 3-4 ACT20-FEED-IN-PRO-S DANGER For safe installation of ACT20-FEED-IN-PRO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. DANGER Do not install or remove modules from the Power Rail unless area is known to be nonhazardous. The ACT20-FEED-IN-PRO-S must be supplied from a power source with double or reinforced insulation to mains. For installation in Zone 2, the module must be installed in an outer enclosure having an IP protection of at least IP54 according to type of protection Ex-n or Ex-e. Cable entry devices and blanking elements shall fulfil the same requirements. Transients are suppressed by an internal transient protection device, which is set to a level not exeeding 40% of the rated voltage. The year of manufacture can be taken from the first two digits in the serial number. 2 Wire cross-section: AWG 26...12 / 0.13...3.31 mm Number of wires per terminal: 1 wire or 2 wires in a common ferrule Tightening torque per terminal, max.: 0.6 Nm IECEx Certificate DEK 11.0048 X Marking Ex nA nC IIC T4 Gc Standards IEC 60079-0:2011, IEC 60079-15:2010 1066540000/02/02.14 203 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) Illustration 7-61: IECEx Installation Drawing, (452691 Sheet 3-4) Terminal (51, 52) Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (53, 54) Backup Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (41, 42, 43) Power Rail Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 204 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Use CH20M BUS-ADP (Bus Cover) to prevent the open mounting rail from being accidentally short circuited. Redundant ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Power is supplied to the Power Rail from two ACT20-FEED-IN-PRO-S modules. Both modules have connections for normal supply and backup supply. 1066540000/02/02.14 205 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) 206 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) FM Installation Drawing The module is available in the following variants: Order No. Installation Drawing Type 8965500000 4 52691 Sheet 5-6 ACT20-FEED-IN-PRO-S DANGER For safe installation of ACT20-FEED-IN-PRO-S the following must be observed: The module may only be installed by qualified personnel familiar with the national and international laws, directives and standards that apply to this region. DANGER To prevent ignition of explosive atmospheres, disconnect power before servicing and do not separate connectors when energized and an explosive gas mixture is present. DANGER Do not install or remove modules from the Power Rail unless area is known to be nonhazardous. WARNING Substitution of components may impair intrinsic safety and/or suitability for Division 2 / Zone 2. The installation and wiring must be in accordance with the Canadian Electrical Code for Canada and National Electrical Code NFPA 70, Article 500 or 505 for installation in USA. The module must be installed in pollution degree 2 or better. The module must be supplied from a Power Supply having double or reinforced insulation. The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends. For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure according to the regulations in the CEC for Canada or NEC for USA. The year of manufacture can be taken from the first two digits in the serial number. c-FM-us Certificate 3043148 Marking CL I DIV2 GP A-D T4 CL I Zn2 AEx/Ex nA nC IIC T4 Standards Class 3600, Class 3611, Class 3810, ANSI/ISA 12.00.01, ANSI/ISA 12.12.02, ISA 60079-15:2002, CSA-E79-15, CSA-C22.2-213 1066540000/02/02.14 207 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) Illustration 7-62: FM Installation Drawing, (452691 Sheet 5-6) Terminal (51, 52) Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (53, 54) Backup Supply Voltage 21.6…26.6 V DC Current 4 A DC Terminal (41, 42, 43) Power Rail Status Relay Non Hazardous Location Zone 2 Installation Voltage max. 250 V AC / 30 V DC 32 V AC / 30 V DC Current max. 2 A AC / 2 A DC 2 A AC / 2 A DC Power max. 500 VA / 60 W 64 VA / 60 W 208 1066540000/02/02.14 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Use CH20M BUS-ADP (Bus Cover) to prevent the open mounting rail from being accidentally short circuited. Redundant ACT20-FEED-IN-PRO-S Power unit with backup. ACT20-FEED-IN-PRO-S shall only be used with the CH20M-BUS supplied by Weidmüller. Use CH20M BUS-AP (Bus End Plate) to prevent the mounting rail from being short circuited by the outer enclosure. Power is supplied to the Power Rail from two ACT20-FEED-IN-PRO-S modules. Both modules have connections for normal supply and backup supply. 1066540000/02/02.14 209 Appendix G. Installation Drawings ACT20-FEED-IN-PRO-S (Power Feed-In Unit) 210 1066540000/02/02.14 Weidmüller Interface GmbH & Co. KG P.O. Box 3030 32720 Detmold Klingenbergstraße 16 32758 Detmold Germany Phone +49 (0) 5231 14-0 Fax +49 (0) 5231 14-2083 E-Mail [email protected] Order number: Internet www.weidmueller.com 1066540000/02/02.14